One Step Forward A full range of generators for industrial, professional and portable applications with diesel or petrol engines, built with the best

Size: px
Start display at page:

Download "One Step Forward A full range of generators for industrial, professional and portable applications with diesel or petrol engines, built with the best"

Transcription

1 Back up sump Pump Systems Edition One Step Forward

2 One Step Forward A full range of generators for industrial, professional and portable applications with diesel or petrol engines, built with the best and primary brands of the engines and alternators market. To be always one step forward is our mission: constant innovation, pursuit of excellence and of the most advanced components, attention to details, customized solutions and projects. On other ords we always find the best solution for our customers. Control panel with innovative design and advanced electronic suitable to any application. Designed for controlling pumps and motors they offer a high level of customization in order to be able to satisfy any kind of application and request. Anti-blackout systems and back-up sump pumps for domestic and professional applications. Elentek lighting towers are made with care and attention pondering each single element to create a detailed chiseled product.

3 Back up sump Pump Systems Technical Features Power supply 1~ 50/60Hz 230V±10%; Batteries input 24Vcc or 36Vcc depending on the model; Single-phase output 1~ 50/60Hz 230V±10%; Output pseudo sine waveform (when working with battery); Efficiency 95%; Automatic battery charger; Deactivation of the load in case of low battery (when working with battery); Multifunction backlit display for the visualization of the system status; Green LED for load active (minimum absorption 1A); Load protection fuse; Batteries protection fuse; Protection against polarity reversal of the batteries; Protection against overload; Protection against overtemperature; Load test settable from the display; Forced ventilation; Main switch interlock with handle for emergency shutdown; Box in methacrylate ABS, protection degree IP32; Ambient temperature -5/+40 C with max relative humidity 50% (not condensed). Note We recommend to use external float switches in order to best use the functions of the system.

4 How to choose TOP 1 TOP VORTEX ENERGY 1 RXm VORTEX 2/20 ENERGY 2 RXm VORTEX 3/20 TOP 2 VXm 8/50 RXm VORTEX 4/40 VXm 10/50 ENERGY 6 RXm VORTEX 5/40 ENERGY 75 VXm 15/50 2x VXm 10/50 2x VXm 15/50 ENERGY 85 PAL 125 HELP COMPACT PAL 125 Head 3 metri HELP 800 HELP 1000 HELP 1200 PAL 125 PAL 125 PAL 150 HELP 1500 PAL 150 HELP 2200 HELP 2600 HELP 3500 HELP 5000 How to choose HELP system Please consider the following parameters in order to find the most suitable system for your installation: 1. Square meters exposed to the rain, for instance the ramp of an underground garage, including in the calculation any other surface bringing water to the zone to drain (roofs, roofings etc). 2. Head that is the difference in level in meters between the point of installation of the pump and the point of discharge of the water. 3. Flow rate of the electric pump, calculated multiplying the total surface in m2 (increased by 20% to consider the pressure drop) multiplied by 1,5. 4. Finally we have to decide the preferred endurance time, usually 1 or 2 hours. It is always possible to increase the endurance by adding more batteries.

5 Back up sump Pump Systems Our solutions Systems for 1 pump HELP ECO With battery holder ECO (in steel sheet) HELP DESIGN With battery holder DESIGN (box in methacrylate) and handle for moving Systems for 2 pumps DUO Option for exchange and/or simultaneous operation in 2 pumps systems DUO 1 cod DUO 2 cod DUO 3 cod Exchange operation Contemporaneous operation with mains supply Operation only of pump n 2 in black-out conditions Exchange operation Contemporaneous operation with mains supply and in black-out conditions (calculate the size of HELP for the total power of the pumps) Exchange operation Contemporaneous operation with mains supply Operation only of pump n 2 in black-out conditions Automatic exchange with pump n 1 in case of trip of the pump n 2 (pump s overload)

6 The back-up sump pump kit HELP is supplied (with batteries) in 2 versions: HELP ECO: the kit is provided with the BASIC battery holder, a painted metallic shelf that can contain up to 3 batteries of 50 Ah, 80 Ah or 150 Ah. HELP DESIGN: the kit is provided with the DESIGN battery holder, consisting in a box in methacrylate ABS resistant to UVA rays. Externally it is visually the same as the classic HELP but inside it has a metallic structure with two shelves for the compartment of 2 batteries (50 Ah, 80 Ah or 150 Ah). It is endowed like HELP with a comfortable handle for the moving and for the opening it is enough to use one tool only. Battery holder DESIGN Battery holder ECO HELP ECO and HELP DESIGN can be provided with the DUO innovative integrated system of exchange/ contemporaneity (when there is not mains supply) for the operation of two electric pumps. HELP

7 Back up sump Pump Systems Anti-flooding systems: applications Sleep peacefully......protect the things you love The anti-flooding systems HELP are studied and designed to protect your rooms against floods and drawbacks caused by temporary black-out often happening during storms or other adverse atmospheric conditions When there is a lack of mains supply HELP converts the 12V batteries supplied voltage in 230V voltage through an inverter, supplying electric energy to the devices connected (electric pumps or others) HELP has an easy installation and it needs a minimum maintenance, such as the periodic control of batteries and their replacement at the end of their running life. The control of the instrument status is simple and fast by checking the LCD display that constantly visualizes messages concerning the operation, the number and the duration of the interventions, the possible alarms. The self-test function is integrated and allows to keep the pumps working correctly and ready for emergency. 8

8 Anti-flooding systems for underground technical room (norma UNI-EN 11292) It is necessary to provide for minimum 30 minutes of emergency electric supply for 1 of the 2 pumps at least. The technical rooms must be connected to the drainage system of the site where they are located, with a gravity connection able to unload a lack of water at least of 20 m3/h. Should this not be possible it is necessary to consider a system of automatic control and protection at least of 2 drainage pumps. Discharge of drainage pump must be not less than the 5% of the maximum discharge. Minimum discharge = 10 m3/h. PUMPS COMPARTMENT

One step forward. Multi-pump and Multi-function control panel

One step forward. Multi-pump and Multi-function control panel One step forward Multi-pump and Multi-function control panel The first control panel with innovative engineering suitable to any application 2 www.elentek.com Express. The universal control panel LET IT

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...

More information

Pumps UK. Domestic Drainage pumps.

Pumps UK. Domestic Drainage pumps. Pumps UK Domestic Drainage pumps www.espa-pumps.co.uk Vigila 1 Drainage Submersible pumps for the drainage of clear water Drainage of clear water, decorative fountains, tanks, etc. Materials Pump body,

More information

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER Chassis Inverter power Rated input Rated output Battery pack Safeties Environment Others Input Voltage Lower Limit Input Voltage Upper Limit Power Input Current Output Voltage Output accuracy Transient

More information

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology. Sine Wave Solar UPS Owner s Manual KSU 1024S, KSU 2048S Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology. Please read this guide carefully before installing the product.

More information

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Power Inverter. User s Manual. Diamond Series CPD1200EILCD Power Inverter Diamond Series CPD1200EILCD User s Manual 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5 2-2 Product Overview & Outlook..5 2-3 Power Requirements

More information

Technical Specification SENTINEL PRO

Technical Specification SENTINEL PRO Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES

More information

Pure sine wave charger inverter Product Manual

Pure sine wave charger inverter Product Manual Pure sine wave charger inverter Product Manual The inverter installer must be professional, for the high pressure in the inverter, unprofessional person please do not open it. The inverter should be installed

More information

Battery charger VAS 5906

Battery charger VAS 5906 VOLKSWAGEN AKTIENGESELLSCHAFT Battery charger VAS 5906 For vehicle power circuit support and float charging for demonstration vehicles in the showroom Reliable energy for individual vehicle presentations

More information

UPS Wizard User s Manual

UPS Wizard User s Manual 1. The communication cable M2502: This is a special designed cable for the communication of UPS with your PC; only connecting with the correct cable, the PC can detect the UPS. 2. The main window of the

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION... CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.

More information

Harness the Power of the Sun

Harness the Power of the Sun Harness the Power of the Sun Solar Controller / Battery Charger User s Manual Nominal Voltage: 12Volts Rated Solar Current: 30Amps / 40Amps Nominal Voltage: 12Volts / 24Volts Auto Rated Solar Current:

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4 USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE

More information

Solar Inverter 3kW-8kW Inverter (off-grid)

Solar Inverter 3kW-8kW Inverter (off-grid) Solar Inverter 3kW-8kW Inverter (off-grid) Max. DC Power Data: 5.67kW-11.52kW Max. DC Voltage: 200V-400V Max. AC Power: 3kW-8kW Output AC Voltage: 220V (Range: 209-231V) Frequency: 50, 60Hz (49.5-60.6Hz)

More information

Solar inverter AX-series

Solar inverter AX-series Power Supplies Inverters Solar inverter AX-series 1-5kVA Multifunctional inverter NEU / NEW PV inverter PV / Battery Charger with 3-stage charge Battery-backed power supply Sine wave inverter with charging

More information

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual USER MANUAL IPS home inverters with UPS function Suitable for UPS: - IPS300-SIN - IPS300-SIN-WM - IPS300-SIN-DC - IPS600-SIN - IPS600-SIN-WM - IPS600-SIN-DC - IPS1000-SIN - IPS1000-SIN-DC - IPS1600-SIN

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9 USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

SAFETY WARNINGS AND GUIDELINES

SAFETY WARNINGS AND GUIDELINES SAFETY WARNINGS AND GUIDELINES Place the inverter in a well-ventilated environment. Ensure that the cooling fan is not blocked and that it operates as intended. Do not use the inverter if the fan fails

More information

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology HGM501 Gen-set Controller USER MANUAL Smartgen Technology Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. OVERVIEW... 4 PERFORMANCE AND CHARACTERISTICS... 4 TECHNICAL DATA... 5 OPERATION... 6 4.1. BUTTON DESCRIPTION...

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER USER MANUAL βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER (OPTIONAL) CHARACTERISTICS LCD display: all systems parameters

More information

Solar off-grid Inverter. SP Junior Series. User Manual

Solar off-grid Inverter. SP Junior Series. User Manual Solar off-grid Inverter SP Junior Series User Manual Contents 1 PREFACE... 3 1.1 Glossary... 3 2 INTRODUCTI... 3 2.1 Description... 3 2.2 Features... 3 2.3 Appearance... 3 3 INSTALLATI... 4 3.1 Safety...

More information

SSL-1500 (12V/24V/48V) / SSL-3000 (12V/24V/48V)

SSL-1500 (12V/24V/48V) / SSL-3000 (12V/24V/48V) SSL-1500 (12/24/48) / SSL-3000 (12/24/48) Programmer LCD Pure Sine Wave Inverter with AC Charger and fixed 40A Solar Charge Controller Feature: General-- * Uninterrupted AC power (UPS function) * Power

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 4: Alarm point for low battery voltage table Model Alarm point SCC-MPPT-300 10.5 V SCC-MPPT-600 21.0 V Table 5: Charging hour table for reference Battery Capacity To 90% capacity @ 25A charging current

More information

ConceptpowerTM Modular kVA

ConceptpowerTM Modular kVA TECHNICAL SPECIFICATIONS ConceptpowerTM Modular 10-15-20-30-40kVA Uninterruptible Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI Classic-Line 10-40kVA Gemini-Line 10-30kVA

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE

More information

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual Table of Contents 1. Important Safety Information. 1 1-1 General Safety Precautions 1 1-2 Battery Precautions..... 2 2. Features... 3 2-1

More information

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA Appliances 420-00300-02 PC TV Light Electricfan Table Of Contents GENERAL PRECAUTIONS... 1 PERSONNEL PRECAUTIONS... 1 INTRODUCTION...

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Battery 12V battery system 24V battery system Type Type Code Bulk Floating Bulk Floating Vented 01 14.3 V 13.2 V 28.6 V 26.4 V Sealed 02 14.3 V

More information

Solar Charge Controller

Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Type Battery Type Code SC-600W MPPT Bulk Voltage Floating Voltage Vented 01 28.6 V 26.4 V Sealed 02 28.6 V 26.8 V Gel 03 28.6 V 27.4 V NiCd 04 28.6

More information

OD10 10A Outdoor Solar Charge Controller

OD10 10A Outdoor Solar Charge Controller OD10 10A Outdoor Solar Charge Controller CHC-OD12-10 User s Manual Page 1 of 14 windynation Revision 2 Table of Contents 1.1 Features...3 1.2 Safety Information...4 1.3 Specifications...4 1.3.1 Electrical

More information

Technical Specifications of Solar PCUs

Technical Specifications of Solar PCUs Solar PCU RATING 100VA 500VA 600VA 600VA/1KVA 2KVA 3KVA 4KVA 5KVA 6KVA 10KVA 10KVA PV CHARGE CONTROLLER RATING 100Wp 500Wp 600Wp 600Wp/1kWp 2kWp 3kWp 4kWp 5kWp 6kWp 10kWp 10kWp Model No. PCU1H24 PCU5H24

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging

More information

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Match 19 GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19 UPS. Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

PureSine 150/300 Pure Sine Wave Inverter User s Manual

PureSine 150/300 Pure Sine Wave Inverter User s Manual PureSine 150/300 Pure Sine Wave Inverter User s Manual 1. Important Safety Instructions WARNING! Before you install and use your Inverter, please read and follow these safety instructions. 1-1. General

More information

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function. User Manual Design Features: 1. PFC function. except BC-1215HT / BC-2407HT 2. LCD remote control. BC-1215HT / BC-2407HT 3. Battery temperature sensor function. 4. Tri-LED color indicator for different

More information

Low Frequency Inverter. User Manual

Low Frequency Inverter. User Manual Pure Sine Wave 220-240V 50-60Hz Low Frequency Inverter User Manual For LK/LW series Power Star inverters only, models: LK2000, LK2000-24, LK3000, LK3000-24, LK3000-48, LK6000-24, LK6000-48 1. Safety precautions

More information

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP

More information

CX-SERIES ADVANCED BATTERY CHARGER

CX-SERIES ADVANCED BATTERY CHARGER CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...

More information

PANcharge1k Battery Charger User's Manual

PANcharge1k Battery Charger User's Manual PANcharge1k Battery Charger User's Manual Ver.1.00E Table of Contents 1. Important Safety Instructions... 3 1-1 General Safety Precautions... 3 1-2 Battery Precautions... 3 1-3 Electromagnetic Disturbance...

More information

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER User Manual 1KVA-5KVA INVERTER / CHARGER Version: 1.7 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A. AKSA Power Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main

More information

General Precautions. Personnel Precautions

General Precautions. Personnel Precautions USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH

More information

TECHNICAL DATA SHEET LAD/CYCLER16KW

TECHNICAL DATA SHEET LAD/CYCLER16KW Devices suitable for the discharge and recharge (controlled) of batteries of various types. Possibility to perform automatic charge and discharge cycles (desulphation). Indispensable in the management

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5

More information

AC CONVERTER / BATTERY CHARGER

AC CONVERTER / BATTERY CHARGER AC CONVERTER / BATTERY CHARGER User s Manual MODEL #: CON120AC12/24VDC Listed to UL 458 and CSA 22.2 NO. 107.1 Standards Contents INTRODUCTION... 3 Important Safety Instructions... 3 1. General Description...

More information

Solar Controller / Battery Charger User s Manual

Solar Controller / Battery Charger User s Manual Solar Controller / Battery Charger User s Manual 1 Congratulations! You have made an excellent choice by purchasing this high quality KORR PWM solar controller which has been manufactured to the highest

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

400W Solar Charger Maximum Power Point Tracker

400W Solar Charger Maximum Power Point Tracker MPPT2-2P Page of 8 This revolutionary maximum power point tracker solar charger was designed using the technology that won GSL Electronics the prestigious 2008 EDN Innovation award. A simple, compact and

More information

GSM Series MPPT PV Controller. Version 1.0. Manual

GSM Series MPPT PV Controller. Version 1.0. Manual GSM Series MPPT PV Controller Version 1.0 Manual 1 Introduction GSM series PV controller is a high-performance Buck solar power equipment, using MPPT (Maximum Power Point Tracking) algorithm makes full

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

BATTERY CHARGERS FAN COOLED HIGH FREQUENCY CHARGERS UP 30% ENERGY SAVINGS! HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 TECHNICAL PECIFICATIONS

BATTERY CHARGERS FAN COOLED HIGH FREQUENCY CHARGERS UP 30% ENERGY SAVINGS! HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 TECHNICAL PECIFICATIONS HIGH FREQUENCY CHARGERS HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 UP 30% ENERGY SAVINGS! FAN COOLED TECHNICAL PECIFICATIONS Main input 230VAC ±10% 50-60Hz High frequency single-phase battery charger

More information

AUE-AUD-AU2E AU2D-AUED

AUE-AUD-AU2E AU2D-AUED AUE-AUD-AU2E AU2D-AUED EN12845 Fire Pump Stations Designation of AUE 120 / 100 - N 80-250/75 + DJ MV 708 AUE: One electric main pump + jockey 120: Rated Flow (m 3 /h) 100: Rated Pressure (Hm) N 80-250/75:

More information

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product Overview...

More information

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS Intelligent Battery System GmbH Seestrasse 24, CH-3600 Thun, Schweiz Tel: +41 33 221 06 16 Fax: +41 33 221 06 17 E-Mail: info@ibs-tech.ch Ultra Sine Inverter (US) Generation 4 (G4) User Guide IBS-USG4_en_v2.0.3.doc

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

VX-ST VORTEX. Submersible pumps in stainless steel. PERFORMANCE RANGE Flow rate up to 650 l/min (39 m³/h) Head up to 15 m

VX-ST VORTEX. Submersible pumps in stainless steel. PERFORMANCE RANGE Flow rate up to 650 l/min (39 m³/h) Head up to 15 m VX-ST Submersible pumps in stainless steel VORTEX Sewage water Domestic use Civil use Industrial use PERFORMANCE RANGE Flow rate up to 60 l/min (9 m³/h) Head up to m APPLICATION LIMITS m maximum immersion

More information

User Manual WT Combi-S Pure Sinus Wave Inverter

User Manual WT Combi-S Pure Sinus Wave Inverter User Manual WT Combi-S Pure Sinus Wave Inverter Contents 1. Important Safety information 1.1. Safety Information part 1 1.2. Safety information part 2 2. General Features 2.1. Product overview 3. Connection

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY Safety Read the following user manual carefully before use to prevent damage to the charger and to protect yourself and others. Keep this user

More information

CLEAR WASTE WATER - RAINWATER

CLEAR WASTE WATER - RAINWATER AR Accumulation and lifting stations Domestic use Agricultural use Civil use PERFORMANCE RANGE 50 Hz n= 2900 min -1 0 50 100 150 200 g.p.m. 0 50 100 150 mp g.p.m. 45 feet 40 125 35 Head H (metres) 4 30

More information

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL 7 Stage Automatic Smart Battery Charger Desulphuration& Maintainer (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1

More information

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger User manual Solar Hybrid 1-5KVA Uninterruptible Power Supply / Charger All rights reserved. The information in this document is subject to change without notice. Thank you for purchasing this series UPS.

More information

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1 IMPORTANT

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

400W / 600W / 1000W / 1500W DIY Wind Turbine

400W / 600W / 1000W / 1500W DIY Wind Turbine 400W / 600W / 1000W / 1500W DIY Wind Turbine Not for 400W Producing power at remote sites Where the utility grid is not available Hybrid system Combination of solar & wind power Low-Power applications

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency AVR Protection Compact

More information

K10. Technical Sheet

K10. Technical Sheet K10 Technical Sheet 2 Inverter + Charge Controller K10 1 Photovoltaic Modules Stand Alone Technical Sheet Electric Diagram 3 Technical Characteristics Contacts Battery Pack K10: Electric Diagram Inverter

More information

K50. Technical Sheet

K50. Technical Sheet K50 Technical Sheet 2 Inverter + Charge Controller + K50 1 Photovoltaic Modules Stand Alone Technical Sheet Electric Diagram 3 Technical Characteristics Contacts Battery Pack K50: Electric Diagram Inverter

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line design means zero transfer time

More information

Mobility. Energy. Anytime. Anywhere.

Mobility. Energy. Anytime. Anywhere. Mobility Energy. Anytime. Anywhere. INDEX Introduction 3 The Impulse II charger 4 Impulse II mobility charger 6 About Victron Energy 7 2 Energy. Anytime. Anywhere. Introduction Mobility and independence

More information

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications. LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications. In case of mains or unit failure the DC UPS function enables

More information

MSB kw

MSB kw Rotary Screw Compressor MSB 11 - - 1 - - kw GB Rotary Screw Compressor MSB MSB range is a modern and aesthetically designed belt driven oil lubricated screw compressor offering a wide choice of variants,

More information

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3 User Manual 5KVA/5KW INVERTER / CHARGER Version: 1.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters

More information

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array. EN Appendix Manual IMPORTANT Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array. Use for 24V battery system only 24V (72 cells) solar panel array. BlueSolar

More information

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This

More information

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter. OWNER S MANUAL DP AUDIO Model No. DN350 12 Volt DC to 115 Volt AC 150 WATT 300WATT HIGH SURGE POWER INVERTER Please read installation and operation instruction before using this Power inverter. Contents

More information

Solar Inverter Manual

Solar Inverter Manual Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage

More information

Application. Battery. Public Grid GS HYBRID INVERTER

Application. Battery. Public Grid GS HYBRID INVERTER GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for

More information

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,

More information

Solar PCU/Inverter 1 KVA to 100 KVA

Solar PCU/Inverter 1 KVA to 100 KVA Solar PCU/Inverter 1 KVA to 100 KVA Megatech Brand The unlimited source of energy. www.consulindia.com Company Profile Consul was founded in 1981 and has over 30 years of experience in power backup and

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41

More information

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS REMOTE LOCATIONS COMMERCIAL VEHICLES RV/MARINE BACKUP POWER Do you need reliable AC power in a vehicle, remote location or for emergency backup?

More information

INSTRUCTION MANUAL CAUTION

INSTRUCTION MANUAL CAUTION FILE: IM_091-128-12E-40-115 Rev B., 2-16-2006 INSTRUCTION MANUAL AUTO CHARGE ODY q AUTOMATIC BATTERY CHARGER MODEL #091-128-12E-40-115 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the

More information

DC TO AC POWER INVERTER USER INSTRUCTION MANUAL. Applicable for: FTS800/FTS1000/FTS1500

DC TO AC POWER INVERTER USER INSTRUCTION MANUAL. Applicable for: FTS800/FTS1000/FTS1500 DC TO AC POWER INVERTER USER INSTRUCTION MANUAL Applicable for: FTS800/FTS1000/FTS1500 Description Power Inverters are products which change direct current (DC) electricity to alternating current (AC)

More information

SOLAR OFF-GRID MPPT PCU ESM3K/48, ESM5K/96, ESM7K5/120, ESM10K/120

SOLAR OFF-GRID MPPT PCU ESM3K/48, ESM5K/96, ESM7K5/120, ESM10K/120 SOLAR OFF-GRID MPPT PCU ESM3K/48, ESM5K/96, ESM7K5/120, ESM10K/120 LCD Advanced MPPT Technology Pure sine wave output LCD screen for user convenience Highest efficiency in its class Temperature compensated

More information

MPPT5012A-DUO-BT MPPT5025A-DUO-BT

MPPT5012A-DUO-BT MPPT5025A-DUO-BT MPPT Dual batterysolar controller User Manual MPPT5012A-DUO-BT MPPT5025A-DUO-BT Thank you very much for buying our product,please read thoroughly before using the prouuct Description of Functions 1. Increased

More information

Intelligent Solar Charge Controller. User's Manual. Please read this manual carefully before you use this product

Intelligent Solar Charge Controller. User's Manual. Please read this manual carefully before you use this product Intelligent Solar Charge Controller User's Manual Please read this manual carefully before you use this product Catalogue 1. Product Introduction...2 2. Installation...3 3. Operation...4 4. Common Fault

More information

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

User Manual Back-UPS BX650CI-MS 230 Vac with AVR User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety

More information

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

INVERTER/CHARGERS Off-Grid Power Solutions

INVERTER/CHARGERS Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS Off-Grid Power Solutions REMOTE LOCATIONS RV/MARINE COMMERCIAL VEHICLES BACKUP POWER www.samlexamerica.com Do you need reliable AC power in a vehicle, remote location

More information

Mass Sine 24/10000 Mass Sine 24/15000

Mass Sine 24/10000 Mass Sine 24/15000 USERS- AND INSTALLATION MANUAL Mass Sine 24/10000 Mass Sine 24/15000 Modular high power inverter system MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands ENGLISH: PAGE 1 Tel.: +31-20-342

More information

User Manual of Battery Charger

User Manual of Battery Charger User Manual of Battery Charger Zhejiang GBS Energy Co., Ltd. 2009 Welcome to use our GBS series Intelligence Battery Charger. Please read this manual before using the instrument. Also please keep this

More information