2 2 Fox Controls reserves the right to make modifications and gives no guarantee of the accuracy of the information contained herein.
3 Catalog Index Part Number Description Page # FC-UB Pockets 6 FC-UP Posts 8 FC-DG Fences 10 FC-DG Gates 12 FC-SB Slide Bolts 14 FC-SB Slide Bolt Model Number Key 25 FC-DV Hand Safety Enabling Device 26 FC-ESTOP Emergency E-Stop 28
4 4 Industrial Barrier Guards Design Features Designed to meet and exceed the requirements of regualtory standards: Occupational Safety and Health Administration (OSHA) American National Standards Institute (ANSI) B11.19 Robotic Industries Association (RIA) R15.06 American Society of Mechanical Engineers (ASME) B15.1 European Standard EN953 Rugged steel solution withstands abusive conditions Various insert options reduce exposure to harsh environments Pocketed modular design makes machine servicing easy while maintaining the structural integrity of the guarding solution Designed to be compatible with all industrial safety devices Standard sizes make design and installation simple
5 5 Application Examples Guarding moving parts of a hazardous machine Controlling entry to an automated work cell and limiting access to hazardous machines Protecting from in-running nip points of a conveyor
6 6 FC-UB Modular Pocket Features Reliable, heavy-duty solution to hardguarding industrial applications Designed specifically for industrial environments Pocketed modular design for easy installation Modularity of posts and pockets make servicing machine simple Optional alignment system recommended for use on irregular factory floors and around entry gates Applications Limit access to hazardous machines Control entry to automated work cells Guard moving parts of machines Prevent access to robot cells Protect from in-going nip points of conveyors and machinery Contain thrown or ejected parts
7 7 FC-UB Modular Pocket Dimensions Width At Base 6 Square Height Standard Floor Mounting Holes Threaded Alignment Holes Post Mounting Holes 5.00
8 8 FC-UP Universal Post Features Reliable, heavy-duty solution to hardguarding industrial applications Designed specifically for industrial environments Pocketed modular design for easy installation Modularity of posts and pockets make servicing machine simple Standard and Custom sizes available Black end caps standard Applications Limit access to hazardous machines Control entry to automated work cells Guard moving parts of machines Prevent access to robot cells Protect from in-going nip points of conveyors and machinery Contain thrown or ejected parts 11N026 Rippburger Rd. Elgin, IL P: F:
9 9 FC-UP Dimensions Width Standard 2.50 x 2.50 Height Standard 72 & 96 Custom Available upon request Technical Data Frame Material Color Stee l OSHA Safety Yellow Available Mounting Options Fence Field Post Corner Post T-Post 2.50 For mounting field fence in straight runs For mounting field fence at right angles For mounting field fence at 3-way or inside corners 2.50 Fence Mounting Holes Universal Post Height Gate Devices Swing Post Latch Post Universal Post For swing gate mounting (hinge side) For gate switch mounting (open side) For mounting devices (ie. safety light curtains, mirrors, etc.) [NOTE: Does not come pre-drilled for devices] Pocket Mounting Holes
10 10 FC-DG Fence Features Reliable, heavy-duty solution to hardguarding industrial applications Designed specifically for industrial environments Pocketed modular design for easy installation Modularity of posts and pockets make servicing machine simple Standard and Custom sizes available Flat black mesh for easy visibility of protected area Other inserts available for shields Applications Limit access to hazardous machines Control entry to automated work cells Guard moving parts of machines Prevent access to robot cells Protect from in-going nip points of conveyors and machinery Contain thrown or ejected parts, hazardous substances (coolants, oils), noise and radiation (weld flash)
11 11 FC-DG Dimensions Width Standard 36 (Post Pitch Center to Center) Custom From 4.0 to 45.5 Width (Center to Center) Fence Height Standard 72 & 96 Custom Available upon request Sweep Standard 7 Custom From 1 to 12 Technical Data Frame Material Color Insert Material Options Wire Mesh Opening Material Color 1-1/2 x 1-1/2 x 3/16 Angled Steel OSHA Safety Yellow 2 x 2 Square or 1 x 1 Square dia. steel Flat Black Height Sweep Note: Posts and Pockets sold separately Shielding Material 1/8 Lexan Margard (Splatter Containment) 1-1/4 Lexan Lexgard (Ballistic Containment) Amber Weld Guard (Weldflash Protection) 2 Noise Guard (Noise Abatement)
12 12 FC-DG Features Reliable, heavy-duty solution to hardguarding industrial applications Swing Gate Designed specifically for industrial environments Pocketed modular design for easy installation Modularity of posts and pockets make servicing machine simple Standard and Custom sizes available Flat black mesh for easy visibility of protected area Orange frame color for easy identification of entry / exit points to machine cells Rugged slide bolt design reduces misalignment and protects gateswitch devices from abuse Applications Limit access to hazardous machines Control entry to automated work cells Guard moving parts of machines Prevent access to robot cells Protect from in-going nip points of conveyors and machinery Contain thrown or ejected parts, hazardous substances (coolants, oils), noise and radiation (weld flash)
13 13 FC-DG Dimensions Width Height Standard 36 (Post Pitch Center to Center) Custom From 4.0 to 45.5 Standard 72 & 96 Custom Available upon request Sweep Standard 7 Custom From 1 to 12 Height Slide Bolt Assembly (Not included) Width (Center to Center) Swing Gate Technical Data Frame Material 1-1/2 x 1-1/2 x 3/16 Angled Steel Color OSHA Orange Insert Material Options Wire Mesh Opening 2 x 2 Square or 1 x 1 Square Material dia. steel Color Flat Black Sweep Note: Posts and Pockets sold separately Gate Open Shielding Material 1/8 Lexan Margard (Splatter Containment) 1-1/4 Lexan Lexgard (Ballistic Containment) Amber Weld Guard (Weldflash Protection) 2 Noise Guard (Noise Abatement) Gate Closed
14 14 FC-SB Slide Bolts Features Durable, heavy-duty solution to interface safety gateswitches with industrial hardguarding applications Designed specifically for industrial environments Built to protect and extend the life of safety gatswitches by aligning actuator before engaging Built in handle for easy use Actuator secured using tamper-proof hardware Hardened steel tongue aligns door before actuating the safety device Lock Open feature prevents system from being reset with personnel inside Actuator retracts to prevent damage or injury Designed to function with any commercially available safety gateswitch
15 15 FC-SB Slide Bolts Hardened steel tongue engages before the actuator, alingning the door and preventing damage to the gateswitch device Built in handle for easy use Actuator secured to assembly with tamperproof hardware Actuator retracts to prevent damage and injury to personnel Lock Open feature accomodates up to three personal locks to prevent safety system from being reset with personnel inside
16 16 FC-SB TX Solenoid Gate Switch FC-SB-ETX Slide Bolts
17 17 FC-SB TZ Solenoid Gate Switch FC-SB-ETZ Slide Bolts
18 18 FC-SB Slide Bolts NZ Gate Switch FC-SB-ENZ
19 19 FC-SB Slide Bolts STI TL8012-S Solenoid Gate Switch FC-SB-S8012
20 20 FC-SB Fortress AutoLok Solenoid Gate Switch FC-SB-FAL Slide Bolts
21 21 FC-SB Fortress AutoStop Gate Switch FC-SB-FAS Slide Bolts
22 22 FC-SB Honeywell GK Solenoid Gate Switch FC-SB-HGK Slide Bolts
23 23 FC-SB Slide Bolts Guard Master TLS-GD2 Solenoid Gate Switch FC-SB-GMTLS
24 24 FC-SB Banner SI-LS42 Solenoid Gate Switch FC-SB-BLS Slide Bolts
25 25 FC-SB Slide Bolt Model Number Key - SB - ETX - L - A - C Slide Bolts VOLTAGE (Optional - Only Required with Switch) A 110 VAC D 24 VDC DIRECTION L Left Hand R Right Hand CONNECTOR OPTION (Optional - Only Required with Switch) C Connector prewired for use with Safe-T-Station N No Connector SWITCH TYPE Brand Model Locking ETX Euchner TX Yes ETZ Euchner TZ Yes ENZ Euchner NZ No S8012 STI TL8012-S Yes FAL Fortress AutoLok Yes FAS Fortress AutoStop No FA1S1 Fortress AKA-SKA Yes HGK Honeywell GK Yes GMTLS Guard Master TLS-GD2 Yes BLS Banner SI-LS42 Yes BQM Banner SI-QM100 Yes
26 Hand Safety Enabling Devices LEDs Momentary Pushbuttons 3 position Trigger switch These Hand Safety Enabling Devices come with a trigger mounted 3- position switch, which meets the requirements of ANSI B , Section The Enabling Device can be used to activate a Bypass Mode in the Safety Circuit. Green and red L ED s indicate switch position per ANSI B , Section The green LED is illum inated when the switch is in the cent er position, the red when it is not. The Enabling Device has front mounted momentary pushbuttons to allow machine jogging while in a bypass mode of operation. Part # FC-DV-ED8P-C-2B Description Enabling Device w/ 8 Pin Connector & 2 Pushbuttons
27 Hand Safety Enabling Device -DV Technical Data Fox Controls Hand Safety Enabling Device FC-DV-ED8P-C-2B Connector Detail
28 28 Emergency Stop FC-ESTOP-20 Features: Emergency Enclosure Self Contained Category 4 Safety Control System Only Requires 120 VAC Supply Interfaces with your existing Motor Starter 11N026 Rippburger Rd. Elgin, IL P: F:
29 FC-ESTOP-20 Emergency Stop 11N026 Rippburger Rd. Elgin, IL P: F:
GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch
Series Dual Entry Solenoid Key Operated Safety Interlock Switch FEATURES Solenoid power to lock or power to unlock Side or top key entry Separate switches for key position and solenoid status Available
More informationHinge Wing Safety Interlock Switches
Hinge Wing Safety Interlock Switches SI-HG80 Series Safety Interlock Switches Encapsulated in a Load-Bearing Hinge Inline QD Fitting Right-Angle QD Fitting Features Safety switch is integrated and encapsulated
More informationData Sheet. AmLok.
Data Sheet AmLok options: amgard safety gate switch solutions consist of a range of Control interlocks. The control Interlocks are split into gate switches (Stops) and solenoid Interlocks (Loks). Combining
More informationABB JOKAB SAFETY Products. Material handling industries Machine safeguarding products
ABB JOKAB SAFETY Products Material handling industries Machine safeguarding products Safety solutions for material handling Continuous operation and sustainability The costs associated with downtime in
More informationCAUTION CM-SE CM-S21 CM-S41
CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and
More informationSafety Door Switches. Contents. Selection Guide F-2. Tongue Switches D4NS F-6 T5009 & T F-14 T4012 F-20 T4016 F-20 T2008 F-21 D4GS-N F-26
Safety Door Switches Contents Selection Guide F-2 Tongue Switches D4NS F-6 T5009 & T5009-6 F-14 T4012 F-20 T4016 F-20 T2008 F-21 D4GS-N F-26 Guardlocking Switches D4SL-N F-27 D4NL F-45 TL4019 F-55 TL4024
More informationRETRO SOLUTIONS PRODUCT CATALOG
RETRO SOLUTIONS PRODUCT CATALOG 4634 S. Presa Street, San Antonio, TX 78223 Phone 210-533-1231 Fax 210-533-2211 www.southernfolger.com See who we are. See all we do. T A B L E O F C O N T E N T S RETRO
More informationHinge Wing Safety Interlock Switches
SI-HG80 Series Safety Interlock Switches encapsulated in a load-bearing hinge Safety switch is integrated and encapsulated into a load-bearing hinge, providing a high degree of protection from intentional
More informationRETRO SOLUTIONS PRODUCT CATALOG
RETRO SOLUTIONS PRODUCT CATALOG 4634 S. Presa Street, San Antonio, TX 78223 Phone 210-533-1231 Fax 210-533-2211 www.southernfolger.com See who we are. See all we do. T A B L E O F C O N T E N T S RETRO
More informationpg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept
pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept pg. 3 TS-6 & TS-16 Mini Sensing Edges Low profile with high sensitivity Immediate activation,
More informationHinge Wing Safety Interlock Switches
Datasheet SI-HG80 Series Safety Interlock Switches Encapsulated in a Load-bearing Hinge Safety switch is integrated and encapsulated into a load-bearing hinge, providing a high degree of protection from
More informationHeavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version
OLYM-S24D-C24D The Olympus 4HD is a heavy duty solenoid controlled access lock available with either a stainless steel tongue actuator or a heavy duty handle. The Olympus 4HD is capable of supporting Category
More informationSystem Benefits. Index. Style 840The amazingly versatile woven wire partition. The Style 840 Solution
Style 840The amazingly versatile woven wire partition. Style 840 System Benefits.........1 Panels & Posts.................2 Hinged Doors..................3 Doors & Windows...............4 Ceilings and
More informationProtecting People, Industry and Productivity
Protecting People, Industry and Productivity Modular Gate Switches amgards40 Modular Gate Switches amgards40 is the latest range of safety interlock switches from Fortress Interlocks. Manufactured in 316
More informationUniversal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:
SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 70 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control
More informationElectric Lock Part List
When the length of your gate is more than 1.5 meters, we recommend installing an Electric Lock. An electric lock provides extra security and stability to your gate system. The lock provides extra protection
More informationHeavy-Duty Safety Interlock Switch with Guard Door Locking
C R US Conforms to EN1088, EN60947--1, EN292, EN60204-1 UL and C-UL listed TL8018- Heavy-Duty Safety Interlock Switch with uard Door Locking High locking force of,00 N (1,236 lb.) locks guard door shut
More informationIDEM Solenoid Interlock Safety Switches
KLP/KLM/KL3-SS Series Housing Solenoid locking, tongue (key) interlock operated Power to unlock 90 degree adjustable head One (KLP) or three (KLM, KL3-SS) 1/2 in. female NPT conduit opening 30mm mounting
More informationD o o r I n t e r l o c k s
D o o r I n t e r l o c k s HST 03_08 EN Haake Technik GmbH - Master Esch 72-48691 Vreden Germany - Tel. +49-0 25 64-39 65-0 - Fax +49-0 25 64-39 65-90 C O N T E N T S B R I E F D E S C R I P T I O N Brief
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Mats and Area Guarding UM Series UM or full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Universal Safety Mat System
More information29 CFR 1910, Subpart O
1 29 CFR 1910, Subpart O 2 3 All parts of the machine which move while the machine is working can cause mechanical hazards. These can include reciprocating, rotating, and transverse moving parts, as well
More informationPower Contactor with Mirror Contacts
LLAME SN COSTO Force-Guided Relays Power Contactor with Mirror Contacts Contents Selection Guide 2 Force-Guided Relays G7SA G7S- -E 3 8 Power Contactor with Mirror Contacts J7KNA-AR G7Z 11 15 1 LLAME SN
More informationUniversal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:
SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 78 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control
More informationMA Series rotary tower automatic Stretch Wrapping Systems
MA Series rotary tower automatic Stretch Wrapping Systems The MA-X is Orion s flagship automatic. The MA-X offers customers the highest speeds and most robust frame design for years of reliable and economical
More informationPneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves
Quic-Pics Catalogue Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Contents: Product Line Overviews 2 Manually Operated Valves 5 Pushbuttons 6 Toggle Switch 8 Knob
More information// TORKLIFT T2 DOUBLE PANTOGRAPH
TorkLift T2 Heavy Duty Scissor Lifts Premium Lift Quality & Durability The TorkLift family is Autoquip's premium series of work station hydraulic lifts. With five times the number of life cycles as competitive
More informationSafety Interlock Switches
Interlock Switches Interlock Switches Selection and Application of Switches..... 186 Flat Pack Style Switches................... 191 Limit Switch Style Switches................. 199 Locking Style Switches....................
More informationFlashing Arrow Panel - 615/815 T/Y
Flashing Arrow Panel - 615/815 T/Y All LED 15-Lamp Portable Flashing Arrow Panel Product Specifications American Signal Company FAP X 15 Page 1 of 8 6/11/17 2755 Bankers Industrial Drive Atlanta, GA 30360
More informationVEHICLE AND PEDESTRIAN CONTROL
VEHICLE AND PEDESTRIAN CONTROL Jacksons design and manufacture a wide range of gates in steel, timber or a combination of both to safe guard the continued security of any installation. Regardless of the
More informationFOLGER ADAM PRICE LIST
FOLGER ADAM PRICE LIST Effective 02/15/2013 INDEX Handing of Locks and Mounting... 2-5 Key Identification Charts... 6-7 Keys, Cylinders and Accessories... 8-9 10 Series and Accessories (Mechanical)...
More informationAn Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches
An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety
More informationSpecification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers
Specification Guide for RMVAC Direct Replacement AC Medium Voltage Circuit Breakers Table of Contents 1.0 General Work Scope... 3 2.0 Standards... 3 3.0 Supplier Qualifications... 4 4.0 Circuit Breaker
More informationTorkLift T1 Heavy Duty Scissor Lift Tables Premium Lift Quality & Durability
TorkLift T1 Heavy Duty Scissor Lift Tables Premium Lift Quality & Durability The TorkLift family is Autoquip's premium series of work station hydraulic lifts. With five times the number of life cycles
More informationSpecifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply
Safety Guard Locking Atlas 5 General 1-2-Opto-electronics 3-Interlock Logic Description The Atlas 5 is a positive-mode, tongue-operated guard-locking interlock switch that locks a machine guard closed
More informationNHP SAFETY REFERENCE GUIDE
4 NHP SAFETY REFERENCE GUIDE CONTENTS SAFETY TECHNOLOGY Risk Reduction Options Permanent Fixed Guard 4-02 Interlocked Guard: 4-03 Limit Switches 4-08 Presence Sensing Technology 4-09 Safety Laser Scanners
More informationTechnical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19
1 echnical data echnical data, 1 0 3 1 104 7 90 Interlock with protection against incorrect locking hermoplastic enclosure contacts Manual release, emergency exit or emergency release Long life Double
More informationHeavy-Duty Hinge-Operated Safety Interlock Switch (Pneumatic) Cam limits guard door opening to 5 degrees before safety contacts are opened.
Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 Description PHP6009 Heavy-Duty Hinge-Operated Safety Interlock Switch (Pneumatic) The PHP6009 is similar to the conventional HP6009 except that it gives
More informationFortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting
More informationSolenoid interlock AZM 200 The non-contact interlock.
Solenoid interlock AZM 200 The non-contact interlock. Solenoid interlock AZM 200 The non-contact Solenoid interlocks demand accurate alignment of actuator and device. This requirement is met on new machinery.
More informationMachine Fencing Solutions
Machine Fencing Solutions automation & robotics Design & Installation Engineering 2013 catalogue Buy online at: www.stodec.com skill, quality and experience It s one thing to be a world leader It s quite
More informationELECTRO-MECHANICAL MINIATURE SEALED. Long life Solder or PC terminals PanelsealedtoIP67
PUSHBUTTON SWITCHES ELECTRO-MECHANICAL MINIATURE SEALED SERIES 48EM: ACTUAL SIZE FLEX-TECH MINIATURE SEALED PUSHBUTTON SWITCHES This rugged multi-option sealed pushbutton series offers the utmost in choices
More informationDatasheet. Electrical Switching / Locking
- Standard, Power to Lock,ASi, Un-Monitored and Individual Safety Circuits + Extended Solenoid Controlled Body is used to manage activities by means of a solenoid control element. There are five basic
More informationSafety Padlocks. The ultimate lockout lock.
BradyID.com/lockouttagout Safety. The ultimate lockout lock. Actual size of Brady s Compact Safety Padlock PADLOCK OVERVIEW A written plan and comprehensive training program are foundational to a successful
More information// COMPACT LIFT. The Original Compact Lift Table. Features and Benefits
The Original Compact Lift Table Designed to support smaller lift projects with capacities large enough to get the job done right, Autoquip offers the original Compact lift table. With five times the number
More informationNEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry
NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls
More informationPanduit.com
Cones Barriers & Barricades 1 Cone Top Warning Signs Cones Temporarily and quickly direct facility traffic. Slips into top of any standard, flexible traffic cone Rugged, 0.060" plastic Same message both
More informationCutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter
Operation, and Maintenance of the Instruction Bulletin Read and understand these instructions before attempting any installation, operation, or maintenance of the. This equipment shall be installed and
More informationSWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES SENSING BUMPERS INTERFACE CONTROLLERS LIGHT CURTAINS CUSTOM DESIGNS
Celebrating 50 Years of Excellence A full spectrum of sensing and signaling products for protection, detection, and safety 1957 In Safety and Sensing 2007 SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES
More informationActuator (DM-F Shown) DM1-CLIN-F
Product Data Sheet DM4-CLIN-F page 1 of 5 DM & DMS Door Module with multiple access locks Description The DM and DMS (full stainless steel version) are robust, modular access interlocks suitable for use
More informationHeavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version
OLYM-S24D-C24D The Olympus 4HD is a heavy duty solenoid controlled access lock available with either a stainless steel tongue actuator or a heavy duty handle. The Olympus 4HD is capable of supporting Category
More informationSafety enclosures Normal atmospheres steel enclosure from 50 to 1600 A
Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function
More informationCable (Rope) Pull Switches Lifeline 4
Emergency Stop Devices Description The cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. The is the only
More information1010A DEADLOCK DOOR MOUNTED FOR SMALL SWINGING DOORS APPLICATION: FUNCTION: CRAFTMASTER HARDWARE CO., INC
DOOR MOUNTED FOR SMALL Maximum security. 1010A-1: KEYED ONE SIDE 1010A-2: KEYED BOTH SIDES For small swinging doors on access panels, plumbing chases, control cabinets, etc. FUNCTION: Key activated locking
More information1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches
. Product Description Eaton s LS-Titan safety interlock switches have been specifically designed for monitoring the position of protective guards, such as doors, flaps, hoods and grilles. All switches
More informationHeavy Duty Industrial Foot Switches
P-1303 819-0523 Heavy Duty Industrial Foot Switches Installation Instructions Failure to follow these instructions may result in product damage, equipment damage, and serious or fatal injury to personnel.
More informationAPEM. LPI series. Tactile pushbutton switches with large actuator. Ø 35 mm actuator
APEM LPI series Front or rear mounting Illuminated or non-illuminated Flexibility of marking Meeting the requirements of EN81-70 Ø 35 mm actuator Distinctive features and applications Common features
More informationCompact Rope-Activated Emergency Stop Switch. DIN mounting pattern for a globally recognized mounting configuration
C R US Conforms to EN418, EN292, EN0947-5-1, EN50041, BS504, ISO1850 UL and C-UL listed ER4020 Compact Rope-Activated Emergency Stop Switch Compact size allows this switch to be used on smaller machines
More information3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT
Safety Guard Locking 440G-MT General 1-2-Opto-electronics 3-Interlock Logic Description The 440G-MT solenoid switch is a positive mode, tongue operated guard locking interlock switch that locks a machine
More informationTechnical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module
The following specification defines the minimum requirements for the supply of motor operated valve actuators with a field communication bus system for remote control. The complete system shall consist
More informationDIOSH Day Peoria, Illinois March 1, :50-2:40pm
DIOSH Day Peoria, Illinois March 1, 2017 1:50-2:40pm OSHA 1910.212 General requirements (a) (1) protect operator & other employees in the machine area from hazards Machine Safeguarding Overview Roger Harrison
More informationJay-El Mark 15 P/N 10732
Jay-El Mark 5 P/N 07 JAY-EL 07 JAY-EL MARK 5 P/N 07 ILLUMINATED SWITCH MEETS REQUIREMENTS OF MIL-S-885 Catalog No. 00G -0 For more information, contact our sales team at 0.5.700 or hmisales@ducommun.com
More informationMotorized Electric Latch Retraction
; SECTION I: OVERVIEW 1. Description The Corbin Russwin MELR Electric Latch Retraction (ELR), refer to Figure 1, works with ED4000 & ED5000 Series exit devices to provide remote-controlled latch retraction
More informationTRAFFIC AND PARKING SYSTEMS SPIKES, BARRIER GATES AND COMPONENTS
TRAFFIC AND PARKING SYSTEMS SPIKES, BARRIER GATES AND COMPONENTS Your comprehensive product offering for traffic and parking applications. TRAFFIC AND PARKING SYSTEMS PRODUCT LINE SPIKES, BARRIER GATES
More informationModified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges
Phone: 800-348-1097 www.aeipaintbooths.com Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges Thank you for the opportunity to work with you on your paint booth project. Below
More informationFortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state
More informationENCLOSURES. WEATHER PROTECTIVE and SOUND ATTENUATED. three levels of sound attenuation. D40-6 to D200-2 D40-6s to D100-6S.
WEATHER PROTECTIVE and SOUND ATTENUATED ENCLOSURES three levels of sound attenuation D-6 to D200-2 D-6s to D100-6S Picture shown may not represent actual package. Features HIGHLY CORROSION RESISTANT CONSTRUCTION
More information3400 Series
3400 Series Hager 3400 Series Grade 1 lock is designed and engineered to withstand the most abusive environments. We ve categorized it extra heavy duty and you can rest assured that it has been tested
More informationEnclosures. Weather Protective and Sound Attenuated Enclosures D40-6 to D200-2 D40-6S to D100-8S. Features
s Weather Protective and Sound Attenuated s D40-6 to D-2 D40-6S to D100-8S Picture shown may not reflect actual configuration Features Highly Corrosion Resistant construction Stainless steel flush fitting
More informationSense7-series Non-contact coded safety switch
Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please
More informationAPOLLO Gate Operators, Inc.
APOLLO Gate Operators, Inc. Model 7200ETL Post Mounted Residential & Heavy Duty Commercial Slide Gate Operator INSTALLATION MANUAL 04/11 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications... 4 Pre-Installation
More informationZONE 09FENCING SECTION
ZONE FENCING De-fence is designed to comply with AS4024.1 when used as machinery guarding. Alternatively, its flexible design lends itself to many applications, including forklift separation and workplace
More informationOperating instructions Solenoid interlock AZM 161../.. 1. About this document. Content
Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides
More informationOperator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics
Table of Contents Emergency Cable Pull Switches Operator Interface Overview...4-2 LIfeline ope Tensioner System (LTS)...4-4 Lifeline 3...4-6 Lifeline 4...4-10 Lifeline 4 Stainless Steel...4-16 Enabling
More informationPress Brake Guarding * * * Press Brake Controls * * * Safety Light Curtains
Press Brake Guarding * * * Press Brake Controls * * * Safety Light Curtains Complies with OSHA, ANSI, UL, and CE Standards Part #28-033 Introduction The trend setting equipment contained within this machine
More informationMartin Tornado Retrofit Valve
Martin Tornado Retrofit Valve Go to Martin Tornado Retrofit Valve web page Martin Tornado Retrofit Valves Retrofit Internal and External Valve Air Cannons Internal Valve Air Cannon External Valve Air Cannon
More informationA01 SERIES PUSHBUTTON SWITCHES, ILLUMINATED OR NON-ILLUMINATED Panel cut-out.630" (16mm)
PUSHBUTTON SWITCHES, ILLUMINATED OR NON-ILLUMINATED A pushbutton assembly requires: Screen + Lamp (if illuminated) + Operator + Switchblock To order, select desired model numbers from tables below. Example:
More informationThe USAutomatic Electric Gate Lock Assembly works with most types of gates and mounting applications.
USAUTOMATIC ELECTRIC GATE LOCK Part Number 070510 Installation Manual The USAutomatic Electric Gate Lock works with an automatic gate operator to securely lock the gate into position without having to
More informationTotalPac 3 Deluge, Electric release Remote controlled system
(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a deluge system trim totally preassembled, pre-wired and factory tested. All electrical and
More informationGate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions
UGB4-KLT with Sliding Handle Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions UGB2-KLT Application: The UGB-KLT Gate Box (incorporating an RFID interlock switch) is designed to fit
More information6200 Series. Strikes for mortise or cylindrical devices. Features and benefits. Overview
6200 Series Strikes for mortise or cylindrical devices Overview Features and benefits Von Duprin electric strikes are known for their reliability, durability and security. The 6200 Series strikes are designed
More informationRETROFIT INSTALLATION
RETROFIT INSTALLATION Installation Instructions C0013536 Pallet Grip Q Series Semi-Automatic Machines Manufacture Date before July, 2010 1 RETROFIT INSTALLATION Table of Contents 1.0 Introduction... 3
More informationActuator Arm and Control Box Mounting
Actuator Arm and Control Box Mounting To wire this operator and complete the installation, refer to a specific control box Wiring/Owner s manual. 6002 Vehicular Swing Gate Operator 6002-065-Y-1-13 Copyright
More informationSeries D7 Pilot Devices
Series General Description... 2 Pushbuttons Non-Illuminated... 4 Illuminated... 12 Emergency Stop Operators Non-Illuminated... 20 Three Position... 22 Twist-to-Release... 24 Keyed... 26 Illuminated...
More informationIP69K Stainless Steel Safety Interlock Switches
IP69K Stainless Steel Safety Interlock Switches Designed specifically for Food Processing, Packaging, Pharmaceutical and Petro-Chemical industries Suitable for CIP Cleaning Fully Stainless Steel IP69K
More information56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions
SECTION I: OVERVIEW 1. Description The Sargent 56- prefix ELR works with 80 Series exit devices to provide remote-controlled latch retraction. It is compatible with the following prefixes: 53 - Latchbolt
More informationS Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES
Fault Indicators S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions Service Information S320-40-1 Contents Product Information...........................1 Safety Information............................2
More informationOperator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics
Table of Contents Emergency Operator Interface Overview...4-2 LIfeline ope Tensioner System (LTS)...4-4 Lifeline 3...4-6 Lifeline 4...4-10 Lifeline 4 Stainless Steel...4-16 Enabling Switches GripSwitch...4-24
More informationIntegral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation
C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model
More informationHeavy Duty Commercial Linear Gate Operator
MAX SUPER ARM 2300 Heavy Duty Commercial Linear Gate Operator Moves heavy gates up to 20 High traffic high wind Self-locking, Mag Lock unnecessary Overload clutch release on 3 ton impact MAX AC control
More informationMICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet
MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series DESCRIPTION MICRO SWITCH GKL/R Series switches are a heavy-duty key operated solenoid safety interlock switch incorporating a key trapping mechanism.
More informationBIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve
BIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve Go to BIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve web page MARTIN TORNADO Exhaust Valves Retrofit Internal
More informationElectrical Options Booklet. Table of Contents
*24228413* 24228413 Electrical Options Booklet Table of Contents EL Wiring... EL Troubleshooting... SD/EL 98/99 Cylinder Dogging... SS Wiring... 330, 350, RX-330 and RX-350 Push Bar Trim Mechanical Installation...
More informationAM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles
AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked
More informationGate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL
Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL 10-04-00 CONTENTS Safety Precautions... 2 Applications... 3 Pre-Installation Checklist...
More informationMartin Screen Vibrators
Martin Screen Vibrators Go to Martin Screen Vibrators web page Operator s Manual M3536 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION OF THE MATERIAL; USER
More informationRP100 Series. 2.4GHZ Extended Range. 32-bit Microprocessor. Radio Receiver Model: RP100 / RP / 10 Digital Output
Engineering & Manufacturing Solutions 2.4GHZ Extended Range RP100 Series Radio Receiver Model: RP100 / RP01000002 / 10 Digital Output Sealed To IP67 32-bit Microprocessor ISO 9001:2008 WITH DESIGN Certificate
More informationHazardous Factory Sealed Control Devices
Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot
More informationIntegral E-stop the lid-mounted E-stop button provides emergency stopping capability at the extreme end of the installation
C R US Conforms to EN418, EN292, ISO/IEC1850, EN0947-5-1 UL and C-UL listed ER019 Combination Rope and Push-Button Actuated Emergency Stop Switch Long rope spans of up to 75 m (24 ft.) for standard model
More informationARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI
II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,
More informationMachine & Process Safeguarding Solution Selection Guide
Machine & Process Safeguarding Solution Selection Guide 2015-2016»» Expert Area»» Light Curtains»» Laser Scanners»» Programmable Safety Systems»» Mats and Edges»» Door Switches»» Emergency Stop Devices»»
More information