DA-GEN Dryden Aqua Generator

Size: px
Start display at page:

Download "DA-GEN Dryden Aqua Generator"

Transcription

1 DA-GEN Dryden Aqua Generator USER MANUAL DESCRIPTION The DA-GEN is an innovative water treatment system and additional an intelligent pool controller. The DA-GEN combines Hydrolysis with Electrolysis with a low mineral content. The Hydrolysis produces free radicals and other oxygen compounds like ozone, peroxide and persulfate. All these oxidants destroy organic substances and pathogens in the water. Free radicals are the strongest oxidants we know. They oxidise and decompose in a few seconds. To guarantee a safe residual disinfection the DA-GEN produces a very small amount of chlorine. In combination with DAISY we need a very low mineral content of to kg MgCl or 0. to. kg NaCl per m. The DA-GEN also controls all your pool equipment centrally. Thanks to WiFi you can check and control your pool system /. Control panel Cell Connection cell Flow detector Main 0V connection ON/OFF switch 0-0 V Amp fuse for panel and cell Amp fuse relays Cell Flow detector Cell connector Cell housing Flow/gas detector (internal) SYSTEM INSTALLATION A Electrical consumption Use of a Amp time delay circuit breaker is recommended for private devices and a A breaker for public devices. In case of sharing the power supply with other devices please consult a technician in order to dimension a correct installation. B Product Maximum consumption Product Maximum consumption 9 DA-GEN DA-GEN DA-GEN 90 W 0W W DA-GEN 0 DA-GEN 0 DA-GEN W 00 W 0 W 0 To Earth C DA-GEN 0 0 W Private Public Variable Rate Pump * Filtration control by external timer Filtration mode: Manual/ON A External pump controller* Flow switch B C Filter with AFM Filter pump APF dosing pump ph dosing pump 0 V Control Panel Free chlorine Measuring cell Cell (always in vertical position if installed without flow switch) ph probe Redox probe or conductivity probe (Optional) 9 0 ph injection ph-minus container (not included) Besgo valve (not included) WiFi module * Filtration control by internal timer LINKS TO FILTER PUMP Filtration mode: See section - Filtration of the Installation manual 0 V

2 INITIAL WATER ADJUSTMENTS Water adjustments Adjust the alkalinity between 00 and 00 ppm. Adjust the ph between.0 and.. Adjust the chlorine between 0. and 0. ppm. Adding activator/salt to the water We recommend to addition of to kg magnesium chloride or kg of normal salt per m of water. The TDS should be at around 00. Add the magnesium chloride or salt directly to your swimming pool water or in the balance tank and let the system run. The system will operate without problems with salt concentrations from g/l to 0 g/l. In outdoor pools it is necessary to use ACO. MAINTENANCE Cleaning the titanium cell If necessary, carry out a monthly visual inspection. To clean the cell: Remove the cell from its support (after turning the filtration system off and closing the necessary valves). Place the cell for no more than 0 minutes in % hydrochloric acid (l of acid for each 0l of water). Once the incrustations have softened remove with a hose to complete cleaning the cell. DO NOT USE METALLIC OR SHARP OBJECTS TO REMOVE INCRUSTATIONS. Scratching the edges or surface of the cell will make it vulnerable to chemicals, deteriorate the cell and invalidate the guarantee. Monthly checks SALT CONCENTRATION: ~00 ppm TDS TITANIUM CELL: Visual inspection to detect incrustations. General maintenance The pool must be vacuumed as usual and the skimmers emptied whenever necessary. FILTER BACKWASHING: Once every week for to minutes should be sufficient (providing the filter pressure does not exceed bar, in which case a filter clean may be necessary). VERY IMPORTANT: Make sure the cell is off while cleaning the filter. If the system controls the filtration pump, use the option filter cleaning of the programmed filtration mode. See section Filtration / Filter Cleaning of the General Installation Guide. DOSING PUMPS: Check regularly to ensure that the container contains liquid to prevent the dosing pump from running dry. ph / Redox / CONDUCTIVITY PROBES: The probes must be cleaned and recalibrated every to months. To clean the probe insert in distilled water (clear liquid). After each clean the probes must be re-calibrated. Also: the probes should never dry out and must be kept wet if stored (when emptying the pool for winterising, make sure to store the probe head in water).

3 TROUBLESHOOTING Blank display Check if ON/OFF switch is illuminated. Check the connection wire between display and motherboard. Check the. A fuse of the device it could have tripped due to overload. Check the power supply 0V/0Hz. If the problem persists contact TECHNICAL SERVICE Excess of chlorine in the water Lower electrolysis cell intensity. If your system includes automatic Redox control, check the Redox setpoint value. Reduce it by 0 to 00 mv. If your system includes free chlorine measurment, adjust the setpoint value. Check redox probe and calibrate it if necessary. Electrolysis does not reach the setpoint value Low water temperature. Check the salt concentration (TDS) in water. Check the cell status (it may be incrusted or calcified). Clean the cell according to the instructions in section. Clean the flow detector situated in the cell housing. Check that the titanium cell is not worn out (remember that the cell is guaranteed for,000 hours, approx. - years of summer usage). Titanium cell incrusted in less than month Very hard waters with a high ph and total alkalinity: balance water adjusting ph and total alkalinity. Check to ensure that the system automatically changes polarity approximately every 00 minutes. Consult with our technical service to consider accelerating the polarity change (auto-cleaning). WARNING: Accelerating the polarity change decreases the cell life (,000 hours) proportionally. Reduce the ph set point to.0 Free chlorine level doesn t reach the setpoint value Increase the filtration hours to hours Increase the electrolysis level. Check the salt concentraion (TDS) in the water. Setpoint value app. 00 ppm. In an outdoor pool: Add ACO to the water. Check if the reagents in test kit are in date. Check if the temperature or number of users has risen. Alarm AL and ph dosing pump stopped The maximum dosing time (standard 00 min.) is accomplished and the acid dosing pump stops in order to avoid the acidification of the water. To delete the message and to restart the metering press ESC ( ). Do the following verifications in order to preclude errors on the device: Verify if the ph probe reading is correct (if not, calibrate the probe or substitute it with a new one); Verify if the acid/base reservoir is full and if the dosing pump is working correctly; Verify the variable speed of the dosing pump. Electrolysis display shows FLOW Check flow detector cable. Clean for incrustations of the flow detector at the top of the cell housing. Check to see if system is free of air (probe must always be submerged). Rust on metallic components in the pool Metallic elements lack standardised earth connection. Contact an electrician to solve the problem. Rusted components are not stainless steel (minimum /VA/.). The salt concentration (TDS) is too high. Polarity reaches maximum intensity, but polarity (auto clean) does not reach maximum intensity If the salt concentration is correct (- kg/m MgCl or kg/m NaCl): The cell is reaching its end of life. As of this moment check the intensity every -0 days. When polarity does not reach medium intensity, we recommend substituting the cell for a new one if it happens during the summer period. If it happens during winter, change the cell before the next summer period. WARNING Keep chemical levels in pool as instructed in this manual. CLEANING FILTER Very Important: Make sure the cell is off while cleaning/backwashing the filter. If the system controls the filtration pump, use the option filter cleaning of the programmed filtration mode. See section Filtration / Filter Cleaning of the General Installation Guide. VERY IMPORTANT Remember that the system needs some time to adapt to your pool and that you will have to increase chemical levels for the first days. EARTHING All metallic components in the pool such as lamps, ladders, heat exchangers, drains or similar elements within m from the pool (0 feet) must be connected to an earth with resistance of less than Ohms. If using heat exchangers, we recommend that they be made of titanium. SECURITY To avoid accidents, children should not handle this product unless supervised by an adult. Children should be supervised at all times when in or near a spa, pool or jacuzzi. HANDLING AND DOSING DANGEROUS CHEMICALS Chemicals should be handled with extreme caution. When preparing acid, always add acid to water, never add water to acid, because very dangerous gases may be produced.

4 DA-GEN Dryden Aqua Generator INSTALLATION MANUAL. CONTROL PANEL ELECTRICAL CONNECTIONS Conductivity probe yellow transparent Cover & Chlorine probe detector FL (rotameter) black brown blue Flow switch FL & ph-minus deposit level TANK & Temperature probe red yellow black 0-0 V max.. A CONNECT ALL THE SENSORS CAREFULLY, A BAD CONNECTION MAY CAUSE IRREPARABLE DAMAGE TO THE DEVICE DRY CONTACT 9 0 Free chlorine red black redox ph Variable speed pump slow medium fast common Device control SLAVE brown blue Connection remote display* Connection WIFI module red yellow green black *IF connecting display s on the device, remember not to connect the remote display in this communication channel. Use the Extern channel instead. N L A A ph ph dosing pump & AUX Dosing pump flocculation APF AUX Besgo backwash valve & FILTER PUMP Filtration control & LIGHT Lighting control 9 & 0 AUX & AUX Heating control &. MAIN SCREEN Heating ON/OFF Status of the auxiliary relays Current time Production intensity in % Automatic measurements: ph/redox/ free chlorine/conductivity (according to options) Statusb of filtration relay (see section - Filtration) man aut hea smt int bst Manual Automatic Heating Smart Intelligent Boost :0 º hydrolysis / electrolysis Cover Pol 00 gr/h % LOW Cu/Ag ionization Pr on Pol 0 ma Pol measures man off ph. OFF.0 AL Rx 00 OFF mv FL AL Cl.00 FL ppm FL TANK man off Water temperature Cover Production automatically reduced to the % selected (see display.) Pol Polarity / Pol Polarity --- Waiting time Flow Low Filtration stopped due to lack of water flow Lack of conductivity or salt / low water temperature / scale on cell / exhausted cell (check working hours) Pol Polarity / Pol Polarity. Maximum ph Setpoint (if using ph-minus) ON/OFF Function of ph dosing pump AL Maximum dosing time exceeded ( to reset the alarm).0 Setpoint ph minimum (if using ph-plus) ON/OFF Status of the chlorine pump FL Flow alarm 00 Minimum RedOx Setpoint AL Maximum dosing time exceeded ( to reset the alarm).00 Free Chlorine Minimum Setpoint FL Flow alarm / FL Error rotameter Cl AL Maximum dosing time exceeded ( to reset the alarm) TANK Chemical tank low level Communication display mother board red indicates communication error Status of lighting relay man Manual / aut Automatic PLUS key Modify value/selection MINUS key Modify value/selection OK key Select/confirm UP key Navigation up DOWN key Navigation down RETURN/ESCAPE key

5 . HYDROLYSIS / ELECTROLYSIS Hydrolysis/Electrolysis: Programming of hydrolysis or electrolysis functions (according to model).. Level: Hydrolysis - Desired disinfection production (%).. Salinity: Measuring g/l of salt in water. See section 9 - Salinity.. Boost: Filtration during h at max intensity. Automatic return to programmed filtration mode. During the boost period the redox control can be deactivated.. Mode: If the device has Free Chlorine and redox probes, choose the parameter that controls the cell s chlorine generation.. Cover: connection of automatic cover. See section 0 - Cover.. MEASUREMENTS / SETPOINTS.... Measurements: Adjustment of setpoints and measuring probes.. Setpoints for each measurement.. Setpoints settings: Ideal setpoints for each of the parameters. The default values are: ph:.0-.; redox: mv; free chlorine: ppm; conductivity: ~ 000. MEASUREMENTS / ph Calibration Optional ph control Metering and control of the ph of the water.... Calibration of ph probe: Recommended every month during the usage season.. Calibration with buffers (buffer solutions ph / ph0 / neutral): Follow the instructions in steps that appear in the display (screen. corresponds to step ). ph... Manual calibration: Allows manual adjustment of the probes only recommended to correct small deviations in the readings.. Without removing the probe from the water, use the plus/minus keys to adjust the reading so it matches your reference value (photometer or other measurement).. MEASUREMENTS / redox Calibration The redox value advises us of the oxidation/reduction potential and is used to determine the sterility of the water. The parameters or setpoints are the minimum/maximum accepted redox levels before the titanium cell is connected/disconnected. Adjusting the ideal redox level (setpoint) is the last step in the system start up sequence. Remember to check the redox set-point every - months and/or if the water parameters change (ph/temperature/conductivity). Optional RedOX control Metering and control of the redox as check value of the free chlorine Calibration of the redox probe: Recommended every months during usage season..0 Calibration with buffer (buffer solution mv): Follow the instructions in steps that appear in the display (screen. corresponds to step ). redox... Manual calibration: Allows adjustment of the probes to decimal point (without buffers) only recommended to correct small deviations in the readings.. Without removing the probe from the water, use the plus/minus keys to adjust the reading so it matches the reference values (photometer or other measurements).

6 . MEASUREMENTS / Free Chlorine calibration Optional Free Chlorine control Metering and control in ppm of the free chlorine of the water..... Calibration of the Free Chlorine probe: Recommended every month during usage season.. Calibration with buffer (photometer DPD): Follow the instructions in steps that appear in the display.. Step of - Calibrate Cl at 0 ppm (offset): Close the water flow through the probe and wait until the reading is less than 0,0 ppm. Wait for to 0 min. Press OK when the reading is close to 0. Free Chlorine probe red black Chlorine probe detector FL (rotameter) black brown blue If using a Variable Speed Pump, calibrate the probe using the most common filtration speed Step of - Calibrate Cl: Increase the water flow until it reaches 0-00 litres/hour. Wait until there is a stable ppm reading. Wait for to 0 min. Press OK when the reading is stable.. Step of - Establish the real ppm values with the plus/minus keys according to your DPD (free chlorine) analysis result..9 Step of - If this screen is not shown repeat the calibration process.. Manual calibration: Open the water flow and set the flowmeter (rotameter) to the correct flowrate (0-00l/h). Wait until the current level is stable. With the plus/minus keys, manually set the water chlorine level (use a manual DPD test kit). Press OK when the DPD value is correct on the display (target measurement).. MEASUREMENTS / Conductivity calibration... Optional Conductivity probe. Calibration of the Conductivity probe: Recommended every month during usage season. Metering and control of the conductivity of the water in. Calibration with buffer (buffer solution µs/ MicroSiemens. 0 µs/ neutro): Follow the instructions in steps that appear in the display (screen. corresponds to step ). Conductivity probe yellow transparent... Manual calibration: Allows adjustment of the probes to decimal point (without buffers) only recommended to correct small deviations in the readings.. Without removing the probe from the water, use the plus/minus keys to adjust the reading so it matches your reference value (photometer or other measurement).. MEASUREMENTS / Temperature calibration Optional Temperature A temperature probe is necessary to activate the filtration modes: heating, intelligent, smart. Temperature probe red yellow black... Temperature calibration: To set the difference between the measured value of the probe and the actual temperature, use the plus/minus and up/down keys. Set to the actual temperature of the probe and press OK.. FILTRATION / Manual mode 0-0 V max.. A DRY CONTACT 9 0 Setup and connection of a Variable Speed Pump, see section - Variable Speed Pump N A L A FILTER PUMP Filtration control &... Filtration: Configuration control of the filter pump. To set, select Filtration and confirm by pressing OK. The mode selection is done in Mode line with the plus/minus keys.. Manual: Manually turns ON/OFF the filtration process. No timing or additional functions. The State (Status) line indicates whether the filtration pump is ON. See section Filter Cleaning below.

7 . FILTRATION / Automatic mode.. Automatic (or with timer): In this mode the filtration is switched in accordance with a timer that allow adjustment of timing of the start and end of the filtration cycle. Timers always operate daily, in cycles of hours. To set the ON/OFF times (up to possible programmable times), select with the up/down keys in the timer line you want to change (- ). The plus/minus keys open the selected start time field. Set the time with plus/minus keys. Scroll with the up key to the minute field and set it up with plus/minus keys. To confirm press OK and to cancel press return/escape. To set the OFF timer, proceed accordingly. See Filter Cleaning section below.. FILTRATION / Smart mode.. Smart*: This mode uses the automatic or timer mode, with its filtration intervals, as a basis. It adjusts the filtration time in function of water temperature. For this reason temperature set points are provided: Between the maximum and minimum temperatures the filtration times will climb linearly and will be governed by the timer. Below the minimum temperature the filtration time will be reduced to minutes, which is the minimum working time. Use the plus/minus keys to set the desired minimum and maximum temperatures. There is an option to activate the antifreeze mode in which the filtration will start if the water temperature falls below C. To set the ON/OFF times (up to possible programmable time), follow the instructions of the Automatic Mode. See Filter Cleaning section below. * Note: Mode only visible if the option to use temperature probe and/or heating is activated in the Installer Menu.. FILTRATION / Heating mode.. Timed heating with option of chilling*: This mode operates in a similar way to the automatic mode, but it also includes an option to work on a relay to control the temperature. The desired temperature is set in this menu, and the system works with a hysteresis of degree (example: the setting temperature is C, the system will activate itself when the temperature drops below C and will not stop before it reaches C). Use the plus/minus keys to set the desired temperatures and ON/OFF for the Heating. Clima OFF: The heating only works within the set filtration periods. Clima ON: Keeps the filtration working when the filtration period is finished if the water temperature is below the temperature set point. When the temperature set point is reached the filtration and the heating will stop and will not switch on again until the next programmed filtration period. To set the ON/OFF times (up to possible programmable times), follow the instructions of the Automatic Mode. See Filter Cleaning section below. * Note: This mode is only visible if the option to use the temperature probe and/or heating is activated in the Installer Menu.. FILTRATION / Intelligent mode.. Intelligent*: In this mode the user has working parameters to guarantee the desired water temperature with minimum filtration hours: Select the desired water temperature and the minimum filtration time (minimum of hours and maximum of hours). The device divides the selected minimum filtration time into fragments which start up every hours. If one of these fragments finishes, without the temperature reaching the desired level, the filtration/heating continues until the desired temperature is reached. In order to keep the filtration-electricity-cost to a minimum, this additional filtration time is subtracted from the subsequent minimum filtration time fragments. The first 0 minutes of each fragment will not be subtracted. Example (see diagram): Minimum temperature = C and minimum filtration time = hours. The desired water temperature and the minimum filtration time is set with the plus/minus keys. See Filter Cleaning section below. ON OFF 0h 0 min h ºC ºC ºC ºC ºC h h h h h h h 9h 0h h h h h h h h h 9h 0h h h h h INTELLIGENT MODE DIAGRAM * Note: This mode is only visible if the option to use the temperature probe and/or heating is activated in the Installer Menu.. FILTRATION / Automatic backwash.. Backwash Mode with Besgo Valve: If the system is equipped with an automatic backwash valve from Besgo, use the follwing settings. A shut down of the pump is not necessary with a Besgo valve. Use AUX! Mode: Choose Auto Start: Choose starting time Interval: Set backwash time in seconds (Recommendation: min. 0 seconds with AFM, min. 00 seconds with Sand) Freq.: Choose frequency (Recommendation: weekly)

8 . LIGHTING 0-0 V max.. A DRY CONTACT Lighting. Manual Mode (ON/OFF).. Automatic Mode: Switches lights ON/OFF according to timer settings. The timers can be configured with frequency: Daily; Every days; Every days; Every days; Every days; Weekly; Every weeks; Every weeks; Every weeks. LIGHT Lighting control 9 & 0... LED spotlight: In case of installallation of LED lights in the pool, use this menu to programme the lighting.. From this menu you can change the color of the lights in the pool. Select the length of tme in seconds in Pulse length and then press Next Program option to apply the pulse. Refer to your LED spotlight manual to set its different colors.. AUXILIARY RELAYS 0-0 V max.. A DRY CONTACT Auxiliary relays:. It is possible to control up to extra auxiliary relays (water features, fountains, automatic irrigation systems, built-in cleaning systems, air pumps for spas, garden lighting, etc.). This menu displays the relays that are still available for use on your device and allow their configuration.. Manual mode (ON/OFF). AUX & APF dosing pump AUX & AUX & Automatic backwash valve (Besgo) AUX Heating control & The auxiliary relays are configured by default. If you want to reassign the relays for other accessories, you must access the Service Menu. Contact your authorised installer Automatic mode: ON/OFF according to a timer that adjusts the start and end of the program. The timers can be configured with a frequency: Daily; Every days; Every days; Every days; Every days; Weekly; Every weeks; Every weeks; Every weeks.. Timer mode: Working time is programmed in minutes. Each time the key on the front panel in relation to the relay is pressed, it will start up for and run for the programmed time. This function is recommended for timing of air pumps for spas.. Rename relays: It is posible to rename each auxiliary relay to suit the use you want to assign. By pressing the plus/minus keys, a pop-up keyboard will appear. Scroll up and down with the up/down keys and left to right with the plus/minus keys. To select a letter press the OK.. SYSTEM SETTINGS Setting of preferred language.. Setting of day and current time.. Setting of the intensity of the display lighting (0-00%) and programming its ON/OFF time Sound: Programming of the system to emit sound for the functions: Keyboard (keys); Notices (pop-up message); Alarms (working alarm); Filtration (start of filtration).. Password: Allows protection of access to the user s menu by activating a password. To enter your password press a combination of keys and the system will memorise them. If you forget the password, there is a master password. Ask your installer/provider x. Cell hours: The system memorises the operation times of the different modules.. System info: Information about the available software version of the TFT display and the power module. It also shows the ID node which is necessary for configuration of the of system s WiFi connection.

9 Green LEDs (ON). WIFI SETTINGS.... Connection WIFI module red yellow green black.9.0 Once the WiFi module is connected to the network with both lights ON, enter in Access the Register option and enter all the data requested. The unit ID node can be found on your device (see section. System Settings - screens. &.). Upon completion of the process, you will have total control of your pool, will be able change parameters such as setpoints, filtration hours and turn ON/ OFF any auxiliary relays.... Internet: Once the WiFi module is connected, restart the unit. The internet option will appear in the settings menu.. WiFi: Select WiFi to scan the available networks accessible to the module. The search will be done automatically.. Select the desired network accessible to the WiFi module.. Enter the password in the pop-up keyboard. Scroll up and down with the up/down keys and left to right with the plus/ minus keys. To select a letter press OK..9 Configuration: For a more detailed configuration enter this menu or contact your installer.. Status: Check the status of your connection.. Test connection: Check that your connection has been successfully established. 9. SALINITY* 0. COVER Salinity: The device shows a measurement of the concentration of salt in the water in g/l, as well as the date and water temperature at the time of the last reading. 9. To acknowledge this measurement, press OK in Salinity in the Electrolysis/ Hydrolysis menu (the process takes between and minutes - display 9.). You can calibrate the system measurement using a external salinity meter (display 9.). 9. If you do not have a temperature probe, enter the value manually for greater accuracy. The salinity measurement is influenced by many factors, like the water temperature or the ph. Remenber to do the adjustment every - months. * Attention: Option only available on some models. Cover &. FLOW SWITCH Optional Flow switch Mechanical security flow switch. Stops the hydrolysis/electrolysis and the dosing pumps if there is no water flow. Flow switch FL & Cover: Connection of automatic cover. 0. There will be a percentage reduction in chlorine production, when the pool cover is closed. When the cover is closed it is not necessary for the system to run at 00%. This function, regulates the optimum level of chlorine generation. It is possible to add an external flow switch to the system. Connect as shown in the image and contact your installer for activation. The titanium cell includes a gas flow sensor, you can combine both for better control. Acid reservoir level TANK &. LEVEL SENSOR (Tank) A level sensor can be connected to the device for control of the available volume chemical reservoirs that the system uses. The installer/ provider should be contacte to activate the sensor. This ensures that the dosing pumps never run out of product thereby avoiding potential damage.. VARIABLE SPEED PUMP 0-0 V max.. A POTENTIALFREIE KONTAKTE Variable Speed Pump: To install a Variable Speed Pump contact your installer.. -. After connecting the pump, each filtration period can be assigned a different speed F: fast, M: medium and S: slow. N A L A FILTER PUMP Filtration control & Variable Speed Pump slow medium fast common..... Filter cleaning: To backwash the filter with a Variable Speed Pump, the fastest speed should be used. Dryden Aqua, 0-0

DA-GEN Dryden Aqua Generator

DA-GEN Dryden Aqua Generator DA-GEN Dryden Aqua Generator USER MANUAL DESCRIPTION The DA-GEN is an innovative water treatment system and additional an intelligent pool controller. The DA-GEN combines Hydrolysis with Electrolysis with

More information

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list OPERATOR'S MANUAL Automatic Genset Controller, AGC-4 Display readings Push-button functions handling Log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

English Version 1.0. Manual. AS Control 2

English Version 1.0. Manual. AS Control 2 2014 English Version 1.0 Manual With the purchase of the (ASC 2), you have an innovative, micro-processor operated switchbox which can efficiently control your swimming pool installation, with ease of

More information

OnCommand Troubleshooting Guide Hayward Industries

OnCommand Troubleshooting Guide Hayward Industries OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters

More information

Control and automatic dosing

Control and automatic dosing Control and automatic dosing For public and residential pools Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control Dosing through automatic

More information

Operating manual. ph / mv controller type M8832N

Operating manual. ph / mv controller type M8832N Mostec AG Mess- und Regeltechnik Lausenerstr. 13A CH-4410 Liestal / Switzerland Tel. 061/921 40 90 Fax 061/921 40 83 Operating manual ph / mv controller type M8832N Description of the «leak proof housing»

More information

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11 Wallbox Commander User Guide 1/11 Welcome to Wallbox Congratulations on your purchase of the revolutionary electric vehicle charging system designed with cuttingedge technology to satisfy your daily needs.

More information

SPEEDRIVE INSTRUCTIONS MANUAL

SPEEDRIVE INSTRUCTIONS MANUAL EN SPEEDRIVE INSTRUCTIONS MANUAL Safety warning. The following symbols shown beside a paragraph represent danger warnings associated to the failure to comply with the corresponding instructions. DANGER!

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

TABLE OF CONTENTS. Firmware Version

TABLE OF CONTENTS. Firmware Version TABLE OF CONTENTS Firmware Version...1 Environmental Conditions...1 Electrical Specifications...1 Warnings...2 Section A: Programming the Controller...3 A 1: The Program Menu...3 A 1.1: Entering the Program

More information

REVISION HISTORY REVISION HISTORY

REVISION HISTORY REVISION HISTORY FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and

More information

AUTOMATIC DOSING SYSTEMS & SALT ELECTROLYSIS

AUTOMATIC DOSING SYSTEMS & SALT ELECTROLYSIS AUTOMATIC DOSING SYSTEMS & SALT ELECTROLYSIS Crystal-clear, clean and hygienic pool water for pure enjoyment of swimming in your pool: high demands are placed on water treatment in the pool, for which

More information

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0 APP EOLE4 Applicable to program versions TAC5 Version DT 2.8.2 & DG 2.7.0 2 THE APP EOLE4 INTERFACE This interface can be used on Android, IOS and PC. Download the app from the App Store/Google Play or

More information

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE MANUAL (DOMESTIC & INTERNATIONAL) SERVICE MANUAL (DOMESTIC & INTERNATIONAL) DUAL TECHNOLOGY FINISHER MODEL 1960 & 1980 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone:

More information

POOL PILOT SOFT TOUCH OPERATING, TROUBLESHOOTING AND TECHNICAL CHEAT SHEET

POOL PILOT SOFT TOUCH OPERATING, TROUBLESHOOTING AND TECHNICAL CHEAT SHEET POOL PILOT SOFT TOUCH OPERATING, TROUBLESHOOTING AND TECHNICAL CHEAT SHEET NORMAL OPERATING MODE OF SOFT TOUCH 1. Output Lights will pulsate to indicate Chlorine production. a. There are 7 lights to indicate

More information

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Operations Manual Automated Fuel Maintenance System FTI-10A & 20A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 07/15/2015 Rev E Fuel Technologies

More information

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102*

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102* User Guide ECL Apex 10 *087R9745* *vijem102* Installation and configuration VI.JE.M1.02 Danfoss 11/2004 DH-SMT VI.JE.M1.02 Danfoss 11/2004 DH-SMT ECL Apex 10 VI.JE.M1.02 Danfoss 11/2004 DH-SMT VI.JE.M1.02

More information

R & D SPECIALTIES ROTROL I USER'S MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL R & D SPECIALTIES ROTROL I USER'S MANUAL TABLE OF CONTENTS INTRODUCTION...2 SPECIFICATIONS...2 CONTROLS AND INDICATORS...3 TIME DELAYS...4 INSTALLATION...5 SYSTEM OPERATION...9 TROUBLESHOOTING...13 OPTIONAL

More information

Power at the service of water

Power at the service of water INSTRUCTIONS AND USER MANUAL POOLeasy ph POOLeasy Rx Power at the service of water Table of contents 1. WARNINGS AND TIPS... 1 1.1 - GUARANTEE AND WARNING... 1 1.1.1 General equipment... 1 1.1.2 Warranty

More information

WARRANTY...1 NOTICE INTRODUCTION USE...8

WARRANTY...1 NOTICE INTRODUCTION USE...8 Contents WARRANTY...1 NOTICE...2 1 INTRODUCTION...3 1.1 ABOUT...3 1.2 UNPACKING...3 1.3 INCLUDED ITEMS...4 1.4 COMPONENTS...4 2 USE...8 2.1 POWER ON...8 2.2 SETTINGS...9 2.2.1 Setup Wizard...9 2.2.2 Set

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

SOLENOID DRIVEN DOSING PUMPS MX series

SOLENOID DRIVEN DOSING PUMPS MX series SOLENOID DRIVEN DOSING PUMPS MX series www.fwtsystems.it INTRODUCING MX SERIES FWT is pleased to introduce MX solenoid driven dosing pumps, a new series which will enable to widen the product range covering

More information

AGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7.

AGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7. Page 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Index Aguapure 100 2 Aguapure 200 2 Lara APS 3 P-Pump 4 Aspendose 5 Tank for chemical 6 Tank with mixer 6 Glass Sensor 7 AguaCon 8 Poolsaver Tetra 10 System

More information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside

More information

Service Manual BLACK DIAMOND SERVICE MANUAL. V.160 November

Service Manual BLACK DIAMOND SERVICE MANUAL. V.160 November BLACK DIAMOND SERVICE MANUAL V.160 November 2011 www.montrealchargeur.com www.battelec.ca www.doctorfleet.com Page 1/30 1. SAFETY PRECAUTIONS 1 Before to start using the Black Diamond Charger, read these

More information

Inlet Controller SB3500 USER'S MANUAL

Inlet Controller SB3500 USER'S MANUAL Inlet Controller USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject to change without notice

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16 User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...

More information

The measurements module provides the following engine features information:

The measurements module provides the following engine features information: 1. INTRODUCTION The CEM6 control board is a monitoring network signal and monitoring and control generator feeding device. The device consists of 2 different modules: - Visualization module. The visualization

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

EGT-100 Operations and Installation Manual

EGT-100 Operations and Installation Manual Page 1 of 11 All specification subject to change 2002-2005 EGT-100 Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual with any

More information

INSTALLER MANUAL USER MANUAL. Contents

INSTALLER MANUAL USER MANUAL. Contents Installation & user manual two way Contents INSTALLER MANUAL Important information General 1. Technical data 2. Description Installation: 1. Positioning the unit 2. Connection. 3. Parts description. 4.

More information

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Subject Underhood G System Error Codes and Symptoms System or Parts affected System or Parts affected Index Underhood70G (V90Gxxx) System or Parts affected... 1 Overview... 1 Identifying your System... 1 Retrieving Logged Error Messages... 1 Error Messages... 3 Error Message Table...

More information

Temperature Controller OVATION 214 User's Guide

Temperature Controller OVATION 214 User's Guide Temperature Controller User's Guide Read this guide carefully before using the controller. 890-00045 rev.00 TABLE OF CONTENTS Page TABLE OF CONTENTS... 2 PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE

More information

OS3050 OS3051. Controller for reverse osmosis plants. Instruction manual. Softwareversion 3.04

OS3050 OS3051. Controller for reverse osmosis plants. Instruction manual. Softwareversion 3.04 OS3050 OS3051 Controller for reverse osmosis plants Instruction manual Softwareversion 3.04 Contents Overview... 1 "PRODUCTION" mode... 1 "STANDBY" mode... 2 "RINSE" Mode... 2 "MAINTENANCE" Mode... 3 "STANDBY

More information

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F www.motor-pump-ventilation.com SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F Owner s manual Main features An all-in-one control and protection unit for any pump. Multicontrol. Vigilec

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

Eminox Electronic Service Indicator

Eminox Electronic Service Indicator ESI Installation and Instruction Manual Eminox Electronic Service Indicator I n s t a l l a t i o n a n d I n s t r u c t i o n M a n u a l LITM004 ESI Installation and Instruction Manual Section Title

More information

DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT

DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT FEATURES Automatic mains failure, Engine control, Gas engine support, Generator protection, Built in alarms and warnings, 3 phase mains voltage inputs

More information

L5000Plus. Programming Guide

L5000Plus. Programming Guide Page 1 of 34 JDE1955 IssB s6 July 2009 Contents Safety.. 3 L5000Plus Programmer Keys 4 Passwords.. 4 L5000Plus Programming Access Levels 4 Operator Level Access 4 Technician Level Access 8 Programmer Level

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output

More information

JConn Inv. PID Controller Instruction Manual

JConn Inv. PID Controller Instruction Manual JConn Inv. PID Controller Instruction Manual This information is specific to the Mypin TA4 based controller sold by JConn Inv. but it should work for most TA4 types - within limits. Table of Contents 1.

More information

INSTRUCTION MANUAL. Handy Polaris

INSTRUCTION MANUAL. Handy Polaris INSTRUCTION MANUAL Handy Polaris **This page is left blank** Table of Contents 1 General... 4 2 Setup... 5 2.1 Calibrate... 5 2.2 Set Salinity... 5 2.3 User Interface...5 2.3.1 Language...5 2.3.2 Temperature

More information

Instruction & Owner s Manual

Instruction & Owner s Manual Instruction & Owner s Manual Table of Contents Page Installation - Plumbing of Chamber 3 Installation - Electronic Control Box 3-4 Transformer Connection 115VDC or 230VDC 4-5 Instructions for use with

More information

TABLE OF CONTENTS INTRODUCTION.3 WARRANTY INFORMATION 4 SAFETY INFORMATION 5 PREPARING YOUR WATER BEFORE INSTALLATION 6

TABLE OF CONTENTS INTRODUCTION.3 WARRANTY INFORMATION 4 SAFETY INFORMATION 5 PREPARING YOUR WATER BEFORE INSTALLATION 6 USER S GUIDE TABLE OF CONTENTS INTRODUCTION.3 WARRANTY INFORMATION 4 SAFETY INFORMATION 5 PREPARING YOUR WATER BEFORE INSTALLATION 6 TOOLS AND PARTS REQUIRED FOR INSTALLATION 7 INSTALLING YOUR SYSTEM PLUMBING..8-9

More information

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL E13 TEMPERATURE PROBE FAILURE E16 HIGH LIMIT 1 EXCEEDED A. TEMP Probe reading out of range. B. Bad Connection. C. Problem with the temperatur e measuring circuitry including the probe. High limit temperature

More information

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2 Fuel Level FL1 Revision#2.0, 28/11/2014 For firmware version 1.2 FL1 - User s manual Page intentionally left blank SECTIONS MECHANICAL INSTALLATION ELECTRICAL INSTALLATION OPERATING INSTRUCTIONS INSTRUMENT

More information

Installation and Operating Instructions. Solar System Controller ISC3030

Installation and Operating Instructions. Solar System Controller ISC3030 Installation and Operating Instructions Solar System Controller ISC3030 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s of the

More information

Do isolate the power supply from other high power systems such as Stereos and Alarms

Do isolate the power supply from other high power systems such as Stereos and Alarms Thank you for purchasing a Smart Ride Air Management System, AIRBAGIT.COM s premier flagship product. This system will meet all of your custom and utility needs and will provide you years of trouble free

More information

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER CD100 Series SINGLE COLUMN CARD DISPENSER Operators Manual Contents 1 Specifications...1 2 Installation...2 2.1 Unpacking and inspection...2 2.2 Installation...2 2.3 Electrical Connections...2 2.4 Initial

More information

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES User Manual SPREADER SYSTEM Proportional three function 12 INPUTS 3 interrupt digital inputs. 3 digital inputs for engine control (alternator, accelerator, oil alarm). 1 digital input for tachometer (squared,

More information

TROUBLESHOOTING TP. Index

TROUBLESHOOTING TP. Index TROUBLESHOOTING TP Index E1 POWER CUT DETECTED... 2 E2 LOCK ERROR... 3 E3 DRAINAGE FAILURE / WATER IN TUB... 6 E4 MAXIMUM WATER LEVEL REACHED... 6 E5 FAULT WATER INLET... 6 E6 HEATING FAULT... 6 E7 MAXIMUM

More information

Marin Control Digital

Marin Control Digital Operation Manual Marin Control Digital Digital Meter for the measurement of Temperature, salinity and specific gravity in saltwater aquariums. Short instructions: ON OFF : Is used to turn the power on

More information

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01 SI AT A22 English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings Safety and use instructions LifeSpeed iq TM - 3-phase chargers ENGLISH SAFETY INSTRUCTIONS GOALS OF THIS MANUAL This manual is aimed at any authorized personnel wanting to use a 3-phase LifeSpeed iq TM

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

FL-100-R (109) Operations and Installation Manual

FL-100-R (109) Operations and Installation Manual Page 1 of 23 All specification subject to change 2002-2005 FL-100-R (109) Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual

More information

ChlorSM Series SALINE CHLORINATOR. Installation, Operation, and Maintenance Manual

ChlorSM Series SALINE CHLORINATOR. Installation, Operation, and Maintenance Manual ChlorSM Series SALINE CHLORINATOR Installation, Operation, and Maintenance Manual TABLE OF CONTENTS 1.0 DESCRIPTION 3 1.1 General Information 3 1.2 Principals of Operation 3 1.3 General Specifications

More information

Instruction of connection and programming of the VECTOR controller

Instruction of connection and programming of the VECTOR controller Instruction of connection and programming of the VECTOR controller 1. Connection of wiring 1.1.VECTOR Connection diagram Fig. 1 VECTOR Diagram of connection to the vehicle wiring. 1.2.Connection of wiring

More information

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03 SI AT A22 English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter Part #: 9047 Table of Contents: Table of Contents 2 Intelli-Feed TM User Interface 3 Equipment Diagnostic Indicators

More information

TABLE OF CONTENTS 1 - GENERAL...3

TABLE OF CONTENTS 1 - GENERAL...3 Instructions for use I TABLE OF CONTENTS Page 1 - GENERAL...3 1.1 - GENERAL SAFETY REGULATIONS...3 1.1.1 - STANDARD SAFETY DEVICES...3 1.2 - FIELD OF APPLICATION...3 1.3 - OVERALL DIMENSIONS...3 1.4- TECHNICAL

More information

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual Page 2 CK and EQ Manual CK and EQ Manual Page 3 Table of Contents CK Front Cover and Drive Assembly...4 OEM General Programming

More information

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus: 1.0 Introduction: This probe is designed to provide an additional help to automotive technicians in trouble shooting of electrical circuits problems in the car. Apart from using the normal multi tester,

More information

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy: π H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count counting scale 1-800-295-5510 uline.com 1-800-295-5510 GENERAL INFORMATION Avoid placing the scale in locations that may hurt accuracy: 1. Temperature

More information

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down 24V to 12V DC-DC Converter has a programmable 12.0 to 15.0V output in

More information

Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Model Rectifier Corporation

Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Model Rectifier Corporation Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Temperature sensor jack Sensor included Model Rectifier Corporation Please read this entire manual including all Safety Cautions,

More information

MP V 8A Electronic Smart Charger. Instruction and Information Manual

MP V 8A Electronic Smart Charger. Instruction and Information Manual MP7428 12V 8A Electronic Smart Charger Instruction and Information Manual In order to ensure correct and safe usage of your battery charger, you should read these instructions carefully. Please retain

More information

CADD -Solis VIP Ambulatory Infusion Pump Model 2120

CADD -Solis VIP Ambulatory Infusion Pump Model 2120 CADD -Solis VIP Ambulatory Infusion Pump Model 2120 Clinician Guide Contents I Description of the CADD -Solis VIP Pump... 4 Indications... 4 Pump Diagram... 5 Pump Descriptions... 5 Keypad... 6 I Pump

More information

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS Nano Nano 2 Nano Hybrid ITECH Creative Technology INDEX 1 INTRODUCTION... 2 1.1 Safety instructions... 2 2 EQUIPMENT... 2 3 USE... 4 3.1 Control panel...

More information

Controller Specification Sheet

Controller Specification Sheet Controller Specification Sheet MC9320AXXXBX Proportional Inhibitor Dosing, Conductivity Bleed Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol Controllers are microprocessor

More information

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER USER MANUAL βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER (OPTIONAL) CHARACTERISTICS LCD display: all systems parameters

More information

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i OPERATING MANUAL Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i Art. nr. 40200801 WHISPER POWER BV ENGLISH: PAGE 1 Kelvinlaan 82 9207 JB Drachten NEDERLANDS: PAGINA 41 Netherlands

More information

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J. EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4

More information

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE SRC STEAM RESET CONTROL An Outdoor Reset Control for Sub-Atmosphere Steam Systems Heat-Timer s theory of steam reset heating is as follows: Pulse the valve open to a limited valve position, very slowly

More information

Reverse Polarity MANUAL. Surechlor S3500

Reverse Polarity MANUAL. Surechlor S3500 Reverse Polarity MANUAL Surechlor S00 Surechlor S00 MANUAL Contents Installation Cell Power pack Off Peak Installation Connecting the Pool Pump Installation Layout Operation Chlorine Control LED Chlorine

More information

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE STANDARD FEATURES Automatic and manual start Multi genset synchronization (up to 8 gensets) Multi genset load sharing (up to 8 gensets) Both

More information

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor Product manual Oil Streak Sensor INTRODUCTION Oil streak sensors are designed to detect traces of oil travelling through air tubes, down to flows as low as 5mm 3 /min. The product utilizes a master and

More information

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This

More information

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS PCT plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS Ver. DESCRIPTION The PCT plus is a pressure controller for refrigeration plants that require control in their suction and discharge stages. With

More information

FP-100 Fuel Pressure and Ammeter Indicator Page 1 of 16. All specification subject to change Aerospace Logic Inc.

FP-100 Fuel Pressure and Ammeter Indicator Page 1 of 16. All specification subject to change Aerospace Logic Inc. Page 1 of 16 All specification subject to change 2002-2003 FP-100 Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual with any

More information

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING AUGUST, 2004 REV.A CURTIS TOLEDO OPERATOR S MANUAL SUPPLEMENT AF Series Compressors VS models with VFD WARNING Personal injury and/or equipment damage will result by failing to pay attention to the vital

More information

BKF Control Panel Instruction Manual for the Owners

BKF Control Panel Instruction Manual for the Owners 1 Contents 2 Exploitation and maintenance... 2 2.1 Control Panel (CP)... 2 2.1.1 Panel Operation... 2 2.1.2 Start Page... 2 2.1.3 Stands... 3 2.1.4 Osmosis... 3 2.1.5 Diagnostics... 4 2.1.6 Engine speed...

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power. Technical Information Gas Slide-In Range JGS8750ADB/S/W JGS8850ADB/Q/S/W Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS 400W SUBMERSIBLE PUMP WITH FOLDING BASE AND FLOAT SWITCH MODEL NO: PSV6A PART NO: 7230695 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE 400W Submersible

More information

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Water Specialist PR Control Valve Programming and Cover Drawing Manual Water Specialist PR Control Valve Programming and Cover Drawing Manual Page 2 PR Man u al PR Manual Page 3 Table of Contents PR Front Cover and Drive Assembly...4 OEM General Programming Instructions...5

More information

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White. MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM H7/1 Green : (-) 200mA Pulse H7 3 Pin H7/3 Blue : (-) 200mA Unlock White LED Indicator Valet Switch H6 2 Pin

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Rally computer 3 Rally computer 3.GPS *

Rally computer 3 Rally computer 3.GPS * Rally computer 3 Rally computer 3.GPS * User manual. Installation and configuration instructions. (with links to video instructions online at : www.rallycomputer.com ) * Content marked applies only to

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION... Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2

More information

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL Temperature Controller TC5+2V4SA Plus USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual Automated Fuel Maintenance System MODEL FTI-2.8 FUEL TECHNOLOGIES INTERNATIONAL 03/01/2011 Rev B - Fuel Technologies - FTI-2.8 OPERATIONS & MAINTENANCE CONTENTS Installation

More information

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

DVFP Series Variable Frequency Drive - Product Manual. pg. 1 pg. 1 Set Up Instructions for DVFP Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. Remove the system from the packaging. Make sure everything is included and

More information

Tracer VMA with AutoReg

Tracer VMA with AutoReg Tracer with AutoReg Flowmeter with Automatic Flow Regulation Operating Instructions RoHS Compliant General The Tracer Flowmeter with AutoReg provides: Analog Flow Output (Selectable 0 to 3.5V, 0 to 5V

More information