Controller Specification Sheet

Size: px
Start display at page:

Download "Controller Specification Sheet"

Transcription

1 Controller Specification Sheet MC9320AXXXBX Proportional Inhibitor Dosing, Conductivity Bleed Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol Controllers are microprocessor based units specifically designed for a wide range of water treatment control and monitoring options. PULSAtrol 9000 units offer ease of installation as the controller and standard flow assembly housing all the relevant sensors and flow switches is supplied pre-mounted on a polypropylene backboard. MC9320AXXXBX is designed to dose inhibitor, on a timed or proportional basis, control bleed via conductivity control and control the addition of an oxidising biocide via Redox control. The unit also has spare timers available to be utilised as required. For example, a secondary non-oxidising biocide can be dosed on a 28 day cycle with up to 24 hour bleed lockout and pre-bleed. The controller allows the optimum dosage regime to be maintained in a cooling tower. The standard unit has a number of upgrade options to enable it to perform additional functions. Key Features Microprocessor based for accurate and reliable control Modular flow assembly with flow switch, quick release sensors and sample port mounted on a polyethylene panel Convenient keypad menu access, display contrast adjustment and Hand/Off/Auto relay control Self charging capacitor to maintain time and history for up to two weeks in the event of power loss to the controller DIN connections for conductivity sensor Panel mounted assembly for ease of installation Modular hardware and software for easy access and servicing IP65 High Impact Resistant PVC enclosure for protection against harsh environments Publication WTP/Ptrol/MC9320/03/08

2 Operation The treated water conductivity and Redox is continuously monitored by the integral cells in the Controller flow assembly which also incorporates a flow switch. The flow switch ensures that all the following controls are only activated when there is flow through the assembly. The ranges of the controller are; 0 to 1000 mv Redox and a selectable range for conductivity between 0 to 500, 2000, 5000, 10,000 and 20,000 microsiemen/cm. Factory setting is 5000 µs/cm. The Set point will be either Rising or Falling. Rising or Falling relates to the natural tendency of the treated water. For the Redox level the Set Point (factory set at 400 mv) will be Falling and oxidising biocide will be dosed when the set point is reached. For conductivity the required Set Point (factory set at 1500 µs/cm) will be Rising. This is because in a cooling tower the concentration of the circulating water will tend to rise and without any blowdown will continue to rise. The Redox control has a limit timer assigned to it. Blowdown Control The correct level of cooling water concentration is maintained by conductivity control. When the set point is reached the solenoid blowdown valve is opened. The solenoid valve will continue to be activated until the level falls below the set point by the Differential (factory set at 100 µs/cm). Then the solenoid valve will close. This is to prevent chattering of the output relay about the set point. Redox Control Redox "Falling" Set Point Redox Control Time The correct level of oxidising biocide within the cooling water system is maintained by Redox control Conductivity Dosage De-activated Dosage Activated "Rising" Set Point Conductivity Control Blowdown Activated Blow dow n De-activated Time High Alarm Differential Set Point Low Alarm High Alarm Set Point Differential Low Alarm As the treated water loses oxidising biocide reserve the Redox level will fall and without any dosage of oxidising biocide the reserve will continue to fall. When the Redox set point is reached the Redox limit timer will either open a solenoid valve on the inlet to a bromine dispenser or start metering pump(s) to inject the oxidising biocide reactant(s) - dependant on method of chemical addition being employed. The solenoid valve or metering pump(s) will continue to be activated until the level rises above the set point by the Differential (adjustable, factory set at 50 mv) then the control device(s) will be switched off. This is to prevent chattering of the output relay about the set point. However, if the Redox output is activated for the period set in the Redox limit timer (adjustable in 1 minute increments up to 23 hours 59 minutes, factory set at 1 hour 30 minutes) but the set point has not been satisfied then activation will be cut off and unit will go into alarm until it is re-set The system will also re-start if treated water condition is satisfied - e.g. if the water is manually dosed to adjust Redox level and satisfy the set point.

3 Inhibitor and Non Oxidising Biocide Control PULSAtrol MC9300 Controllers utilise the concept of tagable timers. Tagable timers offer much greater flexibility as they can be used to control any output device such as a metering pump or a solenoid valve in a wide number of alternative methods. In the MC9320AXXXBX Controller four tagable timers are available to operate the required output devices. Actuation can be by any one of the following modes; Limit; or lockout timer. If this timer is utilised, typically the inhibitor pump is actuated simultaneously with blowdown as controlled by the conductivity reading. In this mode the timer limits the length of time the metering pump can run during any single blowdown cycle. This safeguards against overdosing should blockage occur in the blowdown line for example. The timer is adjustable in one minute increments up to 23 hours and 59 minutes with an elapsed time display. Percent; also referred to as a cycle timer. The timer runs continuously on an adjustable time cycle, such as ten minutes, with the output being activated for an adjustable percentage of the time cycle. The timer is adjustable in increments up to 100% and the cycle time is adjustable from one to 120 minutes. Pulse with accumulator; also referred to as water meter or reset timer. This timer is the one normally used to control inhibitor dosing and accepts pulses from a water meter to actuate the inhibitor metering pump. The timer has an adjustable feed time (Run Time) in one second increments up to 59 minutes and 59 seconds with an elapsed time display. It has a built in accumulator that can count pulses up to 255 before activating the out put with an elapsed pulse counter. Also incorporated into the timer is a pulse totaliser that keeps an on-going count of the number of pulses received by the timer. Percent post blowdown; this timer is adjustable in one percent increments up to 100% of the blowdown time. The timer keeps track of the total blowdown time and activates the inhibitor metering pump when the blowdown deactivates for the percent of the total blowdown time set. The minimum feed time will be one minute.

4 28 day biocide timer with blowdown lockout and pre-blowdown is incorporated in the controller. This provides the ability to dose a biocide on a 28 day programme cycle via four individual programs with a wide range of day and week setting combinations. The dosage duration for the biocide metering pumps is adjustable in one minute increments up to 23 hours 59 minutes. (factory set at 1 hour 30 minutes). The time when actuation occurs can be varied as follows; Biocide Settings Month Week Day * No Month * No Week 4 th Week Sunday Thursday Odd Month 1 st Week Even Week Monday Friday Even Month 2 nd Week Odd Week Tuesday Saturday Every Month 3 rd Week Every Week Wednesday Every Day * If these options are selected, no biocide addition will occur. Blowdown Lock-Out; to ensure biocides are allowed their optimum contact time, blowdown can be prevented from occurring for an adjustable period after biocide dosage has ceased. The lockout time starts when biocide dosage is activated and is adjustable in one minute increments up to 23 hours 59 minutes (factory set at zero). Lock-out is common to all four biocide programs. Pre-Blowdown; the pre-blowdown function of this controller allows for the user to pre-blowdown in advance of the blowdown lock-out. This is to reduce the possibility of scaling due to increased levels of conductivity occurring during the blowdown lock-out period. Pre-blowdown is programmed to occur for a programmed length of time or until a pre-set conductivity limit is reached. The duration time is adjustable in one minute increments and is common to all four biocide programmes. Slaving Relays In addition to the above control options, each relay can be slaved to any other relay or combination of relays such that the slave relay actuation will follow exactly the actuation of the relay or relays it is slaved to. This enables more than one output device to be controlled in response to each input signal. Cables Certain cables are supplied with the controller and flow assembly mounted on the backboard. Sensor cables. All sensor cables are cut to the length required for installation into the provided flow assembly. Flow Switch cables. All flow switch cables are cut to length required for installation into the provided flow assembly. Communications cables. If the communications option is included, a 3 metre cable with a DIN connection on one end for plugging into the controller and a standard RJ-45 connection on the other end is supplied. If the communications option includes the modem, an RJ-45 to RJ-11 adaptor is supplied for connecting into a standard telephone jack.

5 Additional Equipment Requirements The MC9320AXXXBX Controller is a stand alone unit. To operate as a complete system the following equipment must be in place either existing or supplied in addition to the controller. Dosage Pumps The number of dosage pumps required will be dependant on the exact water treatment programme being employed. One pump will be required for the inhibitor. If liquid oxidising biocide is being employed, one or two pumps will be required dependant on then type of oxidising biocide. If nonoxidising biocides are being utilised, one pump for each chemical will be required. Care must be taken to ensure that the pumps are capable of delivering the chemical requirements specified by the controller. Chemical Storage Treatment chemicals will normally be stored in a chemical storage tank. Dosage can be from the container that the chemical is supplied in, but it should be ensured that a means of monitoring usage is available. Solenoid Valve A normally closed solenoid valve will be required for bleed control. If a solid oxidising biocide is being employed, a solenoid valve on the inlet to the dispenser will be required. Impulse Water Meter An impulse water meter will be required, for the cooling tower make up line, to monitor the rate of make up flow into the cooling tower. The K factor, i.e. the volume of water passing through the water meter between impulses generated, will depend on the individual operating parameters. Cables Depending on the options included in the relevant controller, certain cables are supplied separately to order. Water Meters All water meters inputs are available from a single DIN on the controller. When you order a cable for water meters, one end is terminated with the mating DIN for connecting to the controller. The cable is 8-conductor twisted pair. The other end of the cable has no terminals. Colourcoded stripped leads are available for wiring to your specific water meter. Analogue (4-20mA) Outputs All 4-20 ma outputs are available from a single DIN on the controller. When you order a cable for 4-20mA outputs, one end is terminated with the mating DIN for connecting to the controller. The cable is 8-conductor twisted pair. The other end of the cable has no terminals. Colour-coded stripped leads are available for wiring to your analogue output device. Volt-free contact Alarm All volt-free contact alarm outputs are available from a single DIN on the controller. When you order cable for volt-free contact alarms, one end is terminated with the mating DIN for connecting to the controller. The cable is 8-conductor twisted pair. The other end of the cable has no terminals. Colour-coded stripped leads are available for wiring to your alarm input. Options The MC9320AXXXBX is the standard control unit to perform the tasks defined above. If additional features are required, the following options are available at additional cost. Two 4-20 ma recorder outputs are available to drive chart recorders to provide hard copy of the measured Conductivity and Redox readings. Spanish, German or French language displays The PULSAworks communications package can be employed to provide remote or local accountability.

6 Specification Feature MC9320AXXXBX MC9320 Four tagable timers, two water meter totalisers user configured as either a volt-free contact or hall effect, alarm output relay, volt free contact alarm output, conductivity and Redox control with sensors and flow switch mounted in a flow assembly. Controller and flow assembly mounted on a polythene backboard. A Conduit which signifies cable gland connections on base of controller. X No ph settings X English. Varying the 9 th Digit calls up Default language options. A = Spanish, B = German, C = French No remote communications. Varying the 10 th Digit calls up additional cost Communications options. X A = Serial line communications including software. B = Internal modem communications including software. B CE approval X Standard panel with flow assembly Power input 90 to /60 Hz 100 VA Control Output Line 600 VA Display 8 line,64 x 128 Pixels Dot Matrix, Back Lit Graphics Display Electronic Environment to + 52 o C, 100% Humidity Shipping Weight of Backboard, Controller and Flow Assembly (kg) 9.2 Maximum Backboard Width (mm) Maximum Backboard Height (mm) 330.2

7 Cooling Tower Alarm Controller Heat Exchanger Circulating Pump Drain Chemical 1 Inhibitor *Chemical 2 Bromine Reactant A *Chemical 3 Bromine Reactant B Chemical 4 Alternative Biocide Make Up Water Schematic Illustrating Typical Installation Arrangement for PULSAtrol MC9320AXXXBX Inhibitor, Conductivity Bleed and Dual Biocide Dosage Controller - Cooling Tower Application Water Meter Dosage Pumps Union Flow Switch Y Strainer Redox Probe Conductivity Probe Input Power Not all items shown will be present in every application *Note; Method of bromination may be via a solid dispenser, in which case the two dosing pumps are replaced by a solenoid valve on the inlet to a bromine dispenser. Alternatively, the liquid oxidising biocide may be a single chemical, in which case only one pump would be employed. Solenoid Valve Y Strainer

8

Cooling Tower Control & Dosing Bleed, Inhibitor, Timed Biocide, ORP

Cooling Tower Control & Dosing Bleed, Inhibitor, Timed Biocide, ORP DIGI-AB2RX2A-P DIGI-AB2RX2A-P-CABG DIGI-AB2RX2A-P-X/3S DIGI-AB2RX2A-P-X/3S-CABG DIGI-A2RX2A-P DIGI-A2RX2A-P-CABG DIGICHEM -ORP-XP2 Controller with Inhibitor, Non-oxidising Biocide & Chlorine Peristaltic

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information

Dosage Pumps - Installation Guide

Dosage Pumps - Installation Guide and Dosage Pumps - Installation Guide To be read in conjunction with schematics on pages 4, 5 and 6. Location The metering pump should be located in an area that allows convenient access to both the chemical

More information

Manual & Automatic Chemical Control

Manual & Automatic Chemical Control Manual & Automatic Chemical Control Contents Etatron Dosing About Etatron Manual Chemical & Essence Dosing 02-03 02-03 04-07 B-V Peristaltic Pumps 04-05 PKX MA/AL Solenoid Pump 06-07 Manual Chemical Dosing

More information

Excel AD Electromagnetic dosing pump

Excel AD Electromagnetic dosing pump Flow rate Up to 7.6 l/h Pressure Up to 17.3 bar Liquid ends Acrylic, stainless steel, PP, PVC, PVDF, designed for viscous products, designed for degassing products LCD user interface with display of the

More information

TECHNICAL DATA. Measurement and control range: Control function: Control outputs: Display resolution: Housing: Ambient temperature:

TECHNICAL DATA. Measurement and control range: Control function: Control outputs: Display resolution: Housing: Ambient temperature: Revised: 1st January 2011 The DSR is a combination controller for the measuring values ph and redox. The disinfecting power of oxidizing disinfectants (e.g. chlorine, bromine) can be measured and controlled

More information

Technical instructions VisioLON - InterLON

Technical instructions VisioLON - InterLON CERAMIC HEATING EN Technical instructions VisioLON - InterLON Nr 05000635/0 Heating control module for SBM radiant heaters. Specifically designed for gas heating system in industrial, commercial and livestock

More information

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller An IDEX Water & Wastewater Business pulsafeeder.com Boiler Programmable Boiler Controller Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets that we serve. Leading

More information

REVISION HISTORY REVISION HISTORY

REVISION HISTORY REVISION HISTORY FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

Oxiperm 164 D for 30 to 2000 g/h

Oxiperm 164 D for 30 to 2000 g/h GRUNDFOS alldos product information Oxiperm 164 D for 30 to 2000 g/h Preparation of chlorine dioxide from diluted solutions Measurements Measurements Standard system Front installation system 164-xxxDFI

More information

Level and Flow Measurement. Sludge Finder 2

Level and Flow Measurement. Sludge Finder 2 Level and Flow Measurement Sludge Finder 2 Sludge Finder 2 Sludge Finder 2 Is a proven effective sludge blanket interface monitor in both waste water and industrial applications. Sludge Finder 2 provides

More information

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide Introduction: Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide The NCC-002 is capable of controlling two stages of progressive nitrous and fuel. If the NCC-002 is configured only for nitrous,

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

Oxiperm 164 C for 150 to 2500 g/h

Oxiperm 164 C for 150 to 2500 g/h GRUNDFOS alldos product information Oxiperm 164 C for 150 to 2500 g/h Preparation of chlorine dioxide from concentrated solutions Measurements Measurements A G C1 C B M H E F C2 C K L NaClO 2 H O 2 HCl

More information

Manual and Automatic Chemical Control

Manual and Automatic Chemical Control Manual and Automatic Chemical Control Contents Contents About Etatron Manual Chemical and Essence Dosing B-V Peristaltic Pumps B-V Peristaltic Pump Dimensions PKX MA/AL Solenoid Pump PKX Dimensions (wall

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

Updated: October 2012

Updated: October 2012 T: (630) 794-5100 EMERGENCY POWER FUEL SYSTEMS Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com Updated: October 2012 The information

More information

Marsh McBirney Flo-Dar

Marsh McBirney Flo-Dar Marsh McBirney Flo-Dar Accurate Flow Measurement Flo-Dar TM provides the user with highly accurate flow measurements under a wide range of flows and site conditions. By measuring the velocity of the fluid

More information

OS3050 OS3051. Controller for reverse osmosis plants. Instruction manual. Softwareversion 3.04

OS3050 OS3051. Controller for reverse osmosis plants. Instruction manual. Softwareversion 3.04 OS3050 OS3051 Controller for reverse osmosis plants Instruction manual Softwareversion 3.04 Contents Overview... 1 "PRODUCTION" mode... 1 "STANDBY" mode... 2 "RINSE" Mode... 2 "MAINTENANCE" Mode... 3 "STANDBY

More information

Installation and Operations Manual

Installation and Operations Manual Excalibur Water Systems 2.0 HIGH CAPACITY SUPER FLOW SERIES DUPLEX WATER SOFTENER Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com 2.0 High

More information

MC-Balance product information

MC-Balance product information MC-Balance product information Color in Control Postal address Physical address Phone/Fax E-mail/Internet P.O. Box 3016 8600 DA Sneek Koperslagersstraat 31 8601 WL Sneek Ph: +31 (0) 515 570020 info@movacolor.com

More information

Product information. MIRA-P Poultry computer

Product information. MIRA-P Poultry computer Product information Hotraco Agri BV Stationsstraat 142 5963 AC Hegelsom, The Netherlands Tel +31 (0)77 3275020 Fax +31 (0)77 3275021 info@hotraco.com www.hotraco.com MIRA-P Poultry computer Poultry computer

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment Tekna Solenoid driven dosing pumps Your Choice, Our Commitment 02 Solutions for Water & Industry Five times the Flexibility A single outer casing contains 5 different models with flow rates ranging from

More information

WARRANTY...1 NOTICE INTRODUCTION USE...8

WARRANTY...1 NOTICE INTRODUCTION USE...8 Contents WARRANTY...1 NOTICE...2 1 INTRODUCTION...3 1.1 ABOUT...3 1.2 UNPACKING...3 1.3 INCLUDED ITEMS...4 1.4 COMPONENTS...4 2 USE...8 2.1 POWER ON...8 2.2 SETTINGS...9 2.2.1 Setup Wizard...9 2.2.2 Set

More information

PCSCL1-HC1 Chlorine Dosing System With Free Chlorine Analyser & Dosing Pump

PCSCL1-HC1 Chlorine Dosing System With Free Chlorine Analyser & Dosing Pump 550mm PCSCL1-HC1 Chlorine Dosing System With Free Chlorine Analyser & Dosing Pump The AQUA Chlorine Dosing System is a fully engineered measurement and dosing control package for the chlorination of water

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR LAROX PERISTALTIC PUMPS FOR METERING The innovative Larox Peristaltic Pumps for Metering (LPP-M) set a new industry standard for peristaltic pump technology.

More information

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS. User manual Manual version: 2.4 dated 27/02/08 Program code: FLSTDmMCDE LEGGI

More information

3D TRASAR Automation - Boiler Blowdown Equipment

3D TRASAR Automation - Boiler Blowdown Equipment 3D TRASAR Automation - Boiler Blowdown Equipment Reduces water and fuel costs by eliminating excessive blowdown Provides better program control and boiler reliability by maintaining boiler TDS at the optimum

More information

MATRIX LLC LEVEL CONTROL PANEL

MATRIX LLC LEVEL CONTROL PANEL MATRIX LLC LEVEL CONTROL PANEL Installation Operation Maintenance Manual 1-26-09 REV-0.3 1 INDEX Introduction. 3 Product Configurations..... 4 I/O Descriptions. 8 Operation o Intercooler, Accumulator,

More information

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches MiG2 TIME SWITCHES 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches The MiG2 series of timers are programmable 365-day time-switches, incorporating: Multiple switching times per day Single and block

More information

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the

More information

CENTRIFEEDER ELECTRONICS

CENTRIFEEDER ELECTRONICS CENTRIFEEDER ELECTRONICS FOR USE WITH CENTRIFEEDER with Integrated Vibratory Control REV 08/13 ADDENDUM VERSION 6.22 SOFTWARE Copyright 2011 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE

More information

SOLENOID DRIVEN DOSING PUMPS MX series

SOLENOID DRIVEN DOSING PUMPS MX series SOLENOID DRIVEN DOSING PUMPS MX series www.fwtsystems.it INTRODUCING MX SERIES FWT is pleased to introduce MX solenoid driven dosing pumps, a new series which will enable to widen the product range covering

More information

Manual. Series 2EZ. Installation Maintenance Repair Manual

Manual. Series 2EZ. Installation Maintenance Repair Manual Manual Series 2EZ Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES Touchscreen PLS and Graphical Operator Interface in One Unit Five Screen Sizes Available: 5" Color, 6" Monochrome, 8" Color, 9" Monochrome

More information

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP ProMinent Modular design allows selection of the features you need Three diaphragm sizes

More information

PowerView PV380-R2 Mechanical Configuration

PowerView PV380-R2 Mechanical Configuration PowerView PV380-R2 Mechanical Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety directive

More information

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual Page 2 CK and EQ Manual CK and EQ Manual Page 3 Table of Contents CK Front Cover and Drive Assembly...4 OEM General Programming

More information

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP Product Information Stepper Motor-driven Diaphragm Dosing Pump Reliable dosing of chemicals Stepper motor driven diaphragm pumps are particularly suitable for highly accurate, reproducible industrial dosing

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers D4a Metering Pumps with built-in proportional controllers A series of solenoid-driven metering pumps with built-in ph controller, oxidation-reduction potential (Redox) controller or chlorine controller.

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

engineered to order solutions

engineered to order solutions DM-Series engineered to order solutions for Transformer Bushing and Partial Discharge (PD) Monitoring Features & Benefits Bushing Monitoring Partial Discharge Monitoring Optional Thermal Modelling with

More information

Maxima. Base mounted solenoid driven dosing pumps. Your Choice, Our Commitment

Maxima. Base mounted solenoid driven dosing pumps. Your Choice, Our Commitment Maxima Base mounted solenoid driven dosing pumps Your Choice, Our Commitment 02 Solutions for Water & Industry Maxima Flexibility Maxima is a base mounted solenoid driven dosing pump that features new

More information

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS AutoDoseTM Programmable Dispensers From Lyn Distributing Models 1060, 1065, 1070, 1075, 1080 & 1085: Operation & Maintenance AutoDose TM programmable dispensers are battery operated peristaltic pumping

More information

GS2 Series - Introduction

GS2 Series - Introduction GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase

More information

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE SRC STEAM RESET CONTROL An Outdoor Reset Control for Sub-Atmosphere Steam Systems Heat-Timer s theory of steam reset heating is as follows: Pulse the valve open to a limited valve position, very slowly

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT

DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT FEATURES Automatic mains failure, Engine control, Gas engine support, Generator protection, Built in alarms and warnings, 3 phase mains voltage inputs

More information

ECLIPSE Laundry Dispenser Controller

ECLIPSE Laundry Dispenser Controller ECLIPSE Laundry Dispenser Controller Reference Manual Programming and Operation Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com Please check online

More information

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics Cryogenic Liquid Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics A Versatile Level Measurement System... A Variety of Liquids Nitrogen

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH EN SolidFlow Product Information Monitoring of Solids SWR engineering Messtechnik GmbH Using SolidFlow is a sensor especially developed for measuring the flow rate of solids conveyed in metallic ducts.

More information

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008 Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM IV Gas Turbine Flow Monitor Operation / Installation

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 2180 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many

More information

SOLENOID DRIVEN DOSING PUMPS

SOLENOID DRIVEN DOSING PUMPS MAIN COMMON FEATURES SOLENOID DRIVEN DOSING PUMPS LIQUID ENDS Power supply: 230 Vac (±10 / 15%) / 1 phase / 50/60 Hz WETTED PARTS STANDARD conf. Available conf. Reproducibility under standard conditions:

More information

MPA Chassis for Multi-Probe Magnetic Transducers

MPA Chassis for Multi-Probe Magnetic Transducers DESCRIPTION: TYPICAL APPLICATIONS: The MPA chassis is utilized for multi-probe SENIS Magnetic Field-to-Voltage Transducer system with any of SENIS Hall Probes. Characterization and quality control of permanent

More information

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Dioxide 1 GRUNDFOS ALLDOS DISINFECTION

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Dioxide 1 GRUNDFOS ALLDOS DISINFECTION GRUNDFOS ALLDOS DISINFECTION ALLDOS DISINFECTION SYSTEMS with Chlorine Dioxide 1 GRUNDFOS ALLDOS DISINFECTION Content Page Oxiperm 164 D 5 to 2000 g/h for diluted chemicals 8 13 5 7 3 6 9 1 10 2 5 4 Oxiperm

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Operations Manual Automated Fuel Maintenance System FTI-10A & 20A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 07/15/2015 Rev E Fuel Technologies

More information

Laboratory Room Controller

Laboratory Room Controller Technical Specification Sheet Rev. 5, April, 2001 Laboratory Room Controller Description The APOGEE Automation System Laboratory Room Controller (LRC) provides Direct Control (DDC) for laboratory space

More information

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps Overview: gamma/ L Ideal for applications requiring automation, large turndown and/or feed verification (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) Capacity

More information

ECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller. Version 3.5

ECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller. Version 3.5 ECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller Version 3.5 1 Change History: Feb 01, 2005 Mar 16, 2005 May 22, 2005 May 9, 2006 By request from CCS,

More information

INSTRUCTION AND USE MANUAL

INSTRUCTION AND USE MANUAL CONTROL UNITS FOR ENGINE CONTROL AND PROTECTION TYPE CEP-090 INSTRUCTION AND USE MANUAL It is equipped with display to show the INSTRUMENTS: - hour-meter - fuel level indicator - tachometer - battery voltmeter

More information

2006/2007 Product Catalog. The World s Leading SOLAR Controllers

2006/2007 Product Catalog. The World s Leading SOLAR Controllers 2006/2007 Product Catalog The World s Leading SOLAR Controllers OUR COMPANY Morningstar Corporation, founded in 1993, is the world s leading supplier of photovoltaic (PV) controllers. In 2005 we shipped

More information

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS Online data sheet S71 E 1217512 S7 S71 E 1217512 S7 A B C D E F C US Detailed technical data Technical specifications Description Ordering information Type Part no. S71 E 1217512 1217512 Other models and

More information

ADJUSTABLE FREQUENCY CRANE CONTROLS

ADJUSTABLE FREQUENCY CRANE CONTROLS IMPULSE G+ MINI ADJUSTABLE FREQUENCY CRANE CONTROLS The IMPULSEG+ Mini from Magnetek continues our history of providing the most reliable and cost-effective adjustable frequency crane controls available.

More information

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions GRUNDFOS DATA BOOKLET Oxiperm OCD-164 30 to 2000 g/h Preparation of chlorine dioxide from diluted solutions Oxiperm OCD-164 Table of contents 1. General 3 Oxiperm OCD-164 3 Applications 3 No chance for

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

DKG-509 AUTOMATIC MAINS FAILURE UNIT

DKG-509 AUTOMATIC MAINS FAILURE UNIT DKG-509 AUTOMATIC MAINS FAILURE UNIT CANBUS AND MPU VERSIONS DESCRIPTION The controller is a comprehensive AMF unit for single genset standby or dual genset mutual standby operations. The unit is available

More information

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement Data sheet DS/ZMT/LO EN Rev. J ZMT & ZFG Superior technology and quality from the world leader in oxygen measurement Integral reference-air supply option avoids necessity for additional equipment Dual

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication

More information

For reliable control of small, large or multi-system-type lubrication systems

For reliable control of small, large or multi-system-type lubrication systems LMC 301 controller For reliable control of small, large or multi-system-type lubrication systems Models 86500, 86501 Models 86502, 86503 Designed for use with pumps that have no internal controller, the

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

DIG Corporation Irrigation product Specifications

DIG Corporation Irrigation product Specifications DIG Corporation Irrigation product Specifications SECTION 02810 Part 2 Products IRRIGATION SYSTEMS 2.1 Automatic Irrigation Controller [Light][Solar] Irrigation controllers shall be single, solid-state

More information

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320

More information

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems LMC 301 controller For reliable control of small, large or multi-system-type lubrication systems LMC 301-controlled systems can be configured to verify that lubricant is dispensed LMC 301 controller with

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Rain Command Manual. Version A03. November 8, 2001

Rain Command Manual. Version A03. November 8, 2001 Rain Command Manual Version A03 November 8, 2001 Dramm Corporation The RAIN COMMAND is a product of MICROFAN North America. 2000 North 18 th Street Manitowoc, WI 54220 MICROFAN North America is a joint

More information

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 REV F2.0 User's Manual Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 Table of Contents INTRODUCTION...4 Starting TOOLBOX Software... 5 MAIN MENU...6 System Setup... 6 Language... 7 Select

More information

RVD G2383en. Installation. - Compact station - Control cabinet (in the front, on the inner wall or on a

RVD G2383en. Installation. - Compact station - Control cabinet (in the front, on the inner wall or on a 4 319 2968 0 G2383en en Installation Instructions District heating controller for one heating circuit and d.h.w. RVD230 Installation Place of installation In a dry room, e.g. in the heat exchanger room

More information

Electromagnetic flowmeter. Descriptions. Specifications

Electromagnetic flowmeter. Descriptions. Specifications Descriptions The EFM Series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3 to 12 pipe in HVAC, municipal or industrial water, wastewater, pump stations and packaged

More information

ProMinent delta Solenoid Diaphragm Metering Pumps

ProMinent delta Solenoid Diaphragm Metering Pumps Overview: delta Ideal for applications requiring metering pump accuracy with minimal pulsation (see page 127 for spare parts and page 134 for control cables) Continuous or pulsating dosing Configurable

More information

RADIO FREQUENCY SYSTEMS

RADIO FREQUENCY SYSTEMS C14520.016-E.MU0 DOC.:10000008168-02 LAB4 DEHYDRATOR USER MANUAL 1 DRYING CHAMBER 2 HEATER 3 PUMP 4 AIR BACKWASHING HOLE 5 HUMIDITY PROBE 6 DIGITAL PRESSURE GAUGE 7 RELIEF VALVE 8 SHUT OFF VALVE 9 DRY

More information

Control and automatic dosing

Control and automatic dosing Control and automatic dosing For public and residential pools Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control Dosing through automatic

More information

TERMINATOR User Manual

TERMINATOR User Manual TERMINATOR User Manual TERMINATOR User Manual Table of Contents Section Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Introduction Safety Precautions Features and Benefits Overview of the

More information

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE

More information

QUANTUM LX CONTROL PANEL

QUANTUM LX CONTROL PANEL Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor

More information

Kompact. Solenoid driven dosing pumps. Your Choice, Our Commitment

Kompact. Solenoid driven dosing pumps. Your Choice, Our Commitment Kompact Solenoid driven dosing pumps Your Choice, Our Commitment 02 Solutions for Water & Industry Simply Kompact dosing Kompact is a simple and reliable range of micro-processor based wall mounted solenoid

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct

More information

ΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ

ΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ ΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ TI-P403-52 / 4033xxB 1/5 AB Issue 3 and Blowdown Controllers Compact unit for TDS control on large or small boilers. Wall or panel mounted versions. 4 digit LED display (ppm

More information

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps pk_2_071 pk_2_104 Overview: Sigma/ 3 Sigma/ 3 Basic Type (S3Ba) Sigma/ 3 Control Type (S3Ca) Ideal for applications requiring automation, large turndown and/or feed verification (see page 133 for spare

More information

DKG-109J AUTOMATIC MAINS FAILURE UNIT

DKG-109J AUTOMATIC MAINS FAILURE UNIT DKG-109J AUTOMATIC MAINS FAILURE UNIT CANBUS VERSION FEATURES True RMS measurements Automatic mains failure ECU control and monitoring through J1939 CAN J1939 ECU warnings displayed as text Various engine

More information