Orbi 3, G3, G4 Index X (Orbi-3) Performance curve Dimensional information Sectional view & parts list Operation and maintenance manual
|
|
- Cuthbert Dorsey
- 6 years ago
- Views:
Transcription
1 T E C H N I C A L D A T A Orbi 3, G3, G4 Index X (Orbi-3) Performance curve Dimensional information Sectional view & parts list Operation and maintenance manual X (Orbi-G3) Performance curve Dimensional information Sectional view & parts list Operation and maintenance manual X (Orbi-G4) Performance curve Dimensional information Sectional view & parts list Operation and maintenance manual Options available for all models Sanitary fitting BSP threads
2 OPERATION AND MAINTENANCE INSTRUCTIONS ORBI SERIES TANKCLEANERS IMPORTANT: Read all instructions in this manual before operating. As a result of Sellers Cleaning Systems constant product improvement program, product changes may occur. As such, Sellers Cleaning Systems reserves the right to change product without prior written notification. SELLERS CLEANING SYSTEMS 420 THIRD ST PIQUA, OH PH: (937) FAX: (937) sellersclean@cranepumps.com FORM NO A
3 GENERAL The SELLERS "ORBI-3" & "ORBI-G3" "ORBI-G4" are hydraulically driven rotating heads with nozzles ejecting streams of liquid for spanning internal tank surfaces to be cleaned, sanitized, treated, or rinsed. The Orbi-3 nozzles are driven through a 360 path simultaneously random in BOTH the vertical and horizontal plane. The Orbi-G3 model incorporates a set of bevel gears to provide a complete 360 indexing path in both planes, the index pattern of 4 will repeat every 45 revolutions. Both of these units are specifically designed for 3" openings, care must be exercised during insertion and retraction of this unit because of the nozzle swing span The Orbi-G4 incorporates 2 nozzle heads thus 4 nozzles, and is designed for 3.75" openings. The units may be installed on a permanent basis (C.I.P.). Many types of fluids, sanitizers, detergents solvents and caustics may be used through this unit to assist it's cleaning effectiveness. (Please note caution below) The cleaning effectiveness of any unit is proportional to all the applicable variables, such as volume, pressure, chemicals, impingement, drainage, soils, etc. The unit will only operate properly when mounted in the vertical position (suspended or inverted) and can clean almost any type of contained area within its range. Caution: If chemicals, hazardous materials, operations, and equipment are used in conjunction with this cleaning equipment, it is the responsibility of the user to establish appropriate associated safety and health practices. Prior to application, the user must consult and determine the applicability of regulatory (federal, state, local and facility) safety and environmental agency limitations. MODELS Orbi = Orbi-3; Base Standard Model,.234 Nozzles, PSI, GPM LP = Orbi-3LP; Base for Low Pressure,.234 Nozzles, PSI, 7-14 GPM B = Orbi-3B; Base Modification for.203 Nozzles, PSI, GPM C = Orbi-3C; Base Modification for.172 Nozzles, PSI, 8-18 GPM D = Orbi-3D; Base Modification for.125 Nozzles, PSI, 7-13 GPM Orbi-G = Orbi-G3; Geared Base Model,.234 Nozzles, PSI, GPM LP = Orbi-G3; Geared Based LP for.234 Nozzles, PSI, GPM C = Orbi-G3C; Geared Base Mod. for,.172 Nozzles, PSI, GPM CLP = Orbi-G3CLP; Geared Base LP for,.172 Nozzles, PSI, GPM Orbi-G C = Orbi-G4C; Geared Duplex std, (4).172 Nozzles, PSI, GPM CLP = Orbi-G4CLP; Geared Duplex low pressure, (4).172 Nozzles, PSI, GPM B = Orbi-GB; Geared Duplex mod (4).125 Nozzles, PSI, GPM BLP = Orbi-GBLP; Geared Duplex low pressure (4).125 Nozzles, PSI, GPM D = Orbi-G4D; Geared Duplex, (4).125 Nozzles, PSI, GPM DLP = Orbi-G4D; Geared Duplex low pressure, (4).125 Nozzles, PSI, 8-14 GPM MATERIALS The "Orbi" is made of 316 (UNS S31600) stainless steel with the exceptions of the shaft bushings, which are made of Teflon, the nozzle body bushings, which are Gardur (UHMW-PE) and the roll pin and retaining rings which are 420C and 15-7PH stainless steel respectively.. No lubricants are required. 2
4 CONSTRUCTION Referring to drawing , or , the unit consists of two basic components; the drive, comprising of the body, motor, rotor, and shaft; and the nozzle head, comprising of the nozzle body, bushings, nozzles, and elbow shaft. These unit's construction does not require lubrication of any kind for operation. ROTATION The liquid enters the inlet cap (1) and then flows through the oblique and bypass holes in the motor (2) causing a swirling motion in the liquid. This swirling liquid goes down the outside of the vertical shaft (5) past the 6 tooth rotor (3) imparting rotation to the rotor and thus the vertical shaft. The liquid flows through the elbow shaft into the nozzle body (7), to be distributed out each off-set nozzle (12). The rotational speed of these units can be regulated through the use of various motor bypass plugs, which influences the fluid diversion to provide additional speed, reference the trouble shooting section and the drawing parts list for additional information and location. THROUGHPUT The amount of liquid going through a "Orbi" is proportional to the pressure applied. Increasing the pressure will increase the throughput. For specific information refer to the flow curve. Please note the operating pressure range. CLEANING/WETTING RADII The cleaning and wetting distances are a function of rotational speed and liquid pressure applied. The slower the unit rotates and the higher the pressure applied, the greater the distances. The Orbi-3 s maximum wetting radius is about 15 ft (4.6 m) with an effective cleaning radius of 10 ft (3.1 m). The Orbi-G3 s maximum wetting radius is about 22 ft. (6.7 m) with an effective cleaning radius of 15 ft. (4.6m), but actual results will also depend on the type and condition of soils to be removed. SUPPLY SOLUTION PRESSURE The minimum amount of liquid that will satisfactorily run the "Orbi" is about 7 GPM (1.6 M^3/hr) at 30 PSI (2 BAR) and the maximum is about 40 GPM (9.1 M^3/hr) at 300 PSI (20.7 BAR). The Sellers B-Jets will supply the mid-range of these parameters for a single unit depending the model. If there is more than one unit in the system the BX or BZ Jets can supply hot solutions for up to 4 units, provided adequate steam is available. For information on SELLERS INJECTORS (Jets) refer to the separate sections. INSTALLATION The "Orbi" is very easy to install as it has a single female pipe thread connection. It may be installed on a tripod, suspended from a pipe, manhole cover. In all installations a suitable strainer should be used (such as a 20 Mesh "Y" strainer) to prevent dirt or scale from clogging the waterways or openings. Warning: In closed tanks, provisions should be made for adequate venting during operation to allow the escape of any gases or volatile vapors which may be produced during operation. This will also prevent the tank from collapsing due to vacuum formation, which can be caused by a cold rinse cycle in a warm tank. 3
5 OPERATION To start the unit, turn on the fluid. An in-line valve is advised for a slow build-up of liquid pressure in the unit to prevent "water hammer". To stop the unit, turn off the liquid. The unit should always be handled carefully. If the unit is dropped or maltreated it may cause internal damage to the drive pod assembly, which in turn can affect the performance of the unit. If handled properly the unit will perform well and provide dependable service. OPERATION & SPECIFICATION SHEET Refer to drawing , or for assembly and parts list. Pipe Connection 3/4" Female NPSC Operating Pressure Range (Based on Models) PSI ( BAR) Maximum Operating Temperature 250 F (121 C) Flow Capacity (Based on Models) 7-40 GPM ( M^3/hr) Head Rotation Speed (Orbi-3) RPM Head Rotation Speed (Orbi-G3 & Orbi-G4) RPM * Effective Cleaning/Wetting Radius To 15 ft maximum (4.6 m) Nozzle quantity & orifice diameter (Std Models) 2 x.234" ( 5.8mm) Nozzle quantity & orifice diameter (Orbi-G4) 4 x.172" ( 5.8mm) Overall Head Length x Body Diameter 6 1/4" x 2 1/32" (159mm x 51.5mm) Installation Hole diameter (Orbi-3 & -G3) 3" ( 76 mm) Installation Hole diameter (Orbi-G4) 3.75" ( 89 mm) Approximate Weight (Orbi-3 & -G3) 2 lbs (.9 kgs) Approximate Weight (Orbi-G4) 3 lbs (1.4kgs) Materials of Construction 316 Stainless Steel, Teflon & UHMW-PE ** Recommended Solution Strainer (not included) 20 Mesh (1/32" openings) * Depends on type and conditions of soils to be removed ** Required for most applications to prevent fouling or plugging of the unit from foreign material, i.e., scale, grit, and soils in solution. Additional strainers and/or finer mesh screens may be required depending upon the amount, nature, and size of foreign materials in solution. NOTE: Consult Sellers where operating conditions are not covered in the above specifications. TROUBLE SHOOTING Due to the simplicity of the unit, very few problems should occur. If any trouble should arise, the following steps may be taken: Refer to the drawing , , or A. Check units for external damage, look for evidence of mishandling that may have damaged shafts, bearings, or alignment. B. If the nozzle body fails to rotate and no liquid passes: 1. Check for liquid pressure and volume at the unit. 2. Check strainer for filter blockage. 3. Remove nozzles and check for obstructions. 4. While nozzles are off, recheck for flow through the nozzle body. C. If the unit fails to rotate and sufficient liquid passes: 1. Check for freedom of rotation, by hand, in the vertical and rotational axis. 2. If the unit is free, insert a motor bypass plug. The motor bypass plug port is located in the top center of the motor. The purpose of the plug is to divert the pressurized fluid to the side drive holes of the motor, thus providing more driving power to overcome any frictional build-up that may occur after extended use. There 4
6 are 2 standard sized plugs included with every unit, a drilled plug with a orifice, which will provide an incremental speed increase and a solid plug, which diverts all the fluid thus giving the fastest rotation If the unit now rotates, the problem is minor friction. If the unit still does not rotate, check for: a. Contamination in the unit. b. Wear of the Teflon and Gardur parts: the bushings, washers, and the rotor. c. Galling and straightness of the shafts. Replace all defective parts. No lubrication! SERVICING-DISASSEMBLY A. Refer to drawing , or Unscrew inlet cap (1) and remove motor (2) from body (4). 2. Hold elbow shaft (9) and unscrew rotor (3) and vertical shaft (5). 3. Push out bushing (6) and washer (14) from body (4). 4. Unscrew cap (10) from elbow shaft (9). 5. Remove nozzle body (7) from elbow shaft (9). 6. Unscrew nozzles (12) from nozzle body (7). 8. Remove rings (11) from body and pull out bushings (8). 9. Orbi-G3, G4 only, remove snap ring (15) and pull off gear (16). SERVICING-ASSEMBLY A. Refer to drawing , or Orbi-G3, G4 place gear (16) over body (4) until pin engages locating pin (17) and install ring (15). 2. Press bushing and washer (6) and (14) into body (4). 3. Screw shaft (5) to elbow shaft (9). 4. Screw rotor (3) onto shaft (5). 5. Insert motor (2) in body (4). 6. Install inlet cap (1) into the body. 7. Assemble bushings (8) into nozzle body (7). 8. Assemble retaining rings (11) into nozzle body (7). 9. Screw nozzles (12) into nozzle body (7). 10. Assemble nozzle body (7) onto elbow shaft (9) and tighten cap (10), tighten with wrench. 5
7 PARTS FOR "Orbi-3" ( ) & Orbi-G3 ( ) & Orbi-G4 ( ) PART NO. REFERENCE NO. DESCRIPTION 1 (3, G3, G4) Cap, Inlet 2 (3) Motor, Water, 2 Drv. Holes (G3, G4) Motor, Water, 4 Thrd. Drv. Holes 3 (3, G3, G4) SS Rotor, 6T-SS 4 (3) Body, Main (G3, G4) Body, Main altered for Gear 5 (3) Shaft, Vertical, 1.69 Lg. (G3, G4) Shaft, Vertical, 1.75 Lg. **6 (3, G3) Bushing-TFE (G4) Bushing-TFE 7 (3) Body, Nozzle (G3, G4) Body, Geared, Nozzle **8 (3, G3, G4) Bushing, Nzl Body 9 (3) Shaft, Elbow, 4 Hole (G3) Shaft, Elbow, 12 Hole (G4) Shaft, Elbow, Duplex 10 (3, G3, G4) Cap, Shaft **11 (3, G3, G4) Ring, Retaining 12 (3, G3) AA Nozzle, 15/64" (.234 ) (3) BA Nozzle, 13/64" (.203 ) (3, G3, G4) CA Nozzle, 11/64" (.172 ) (3, G4) DA Nozzle, 1/8" (.125 ) (NOTE: ** Vane, Stream Straightener are used on all nozzles) 13 (3, G3, G4) Motor Bypass & Motor Drive Plugs ** Solid A Orifice B Orifice.09 ** C Orifice D Orifice E Orifice.16 **14 (3) Washer, TFE (G3, G4) G Washer, UHMW-PE 6
8 15 (G3, G4) Ring, Retaining 16 (G3, G4) Gear, Bevel 17 (G3, G4) Pin, Roll, (G3) E Orifice.156 (G4) D Orifice.140 * Recommended spare parts ** Plugs supplied with unit 7
9 LIMITED WARRANTY We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in material and workmanship under normal use and service for the following time periods, when installed and maintained in accordance with our instructions. Pump Products: One (1) year from date of installation or (24) twenty-four months from date of shipment, whichever occurs first. Cleaning Products: Six (6) months from date of installation or twelve (12) months from date of shipment, whichever occurs first. As used herein, the ultimate consumer is defined as the purchaser who first uses the product after its initial installation or, in the case of product designed for nonpermanent installation, the first owner who used the product. It is the purchaser s or any sub-vendee s obligation to make known to the ultimate consumer the terms and conditions of this warranty. This warranty gives you specific legal rights, and there may also be other rights which vary from state to state. In the event the product is covered by the Federal Consumer Product Warranties Law (1) the duration of any implied warranties associated with the product by virtue of said law is limited to the same duration as stated herein, (2) this warranty is a LIMITED WARRANTY, and (3) no claims of any nature whatsoever shall be made against us, until the ultimate consumer, his successor, or assigns, notifies us in writing of the defect, and delivers the product and/or defective part (s) freight prepaid to our factory or nearest authorized service station. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply. THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT TO ANY PRODUCT SHALL BE TO REPLACE OR REPAIR AT OUR ELECTION, F.O.B. POINT OF MANUFACTURE OR AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE NO FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE, OR OTHERWISE. Unless expressly stated otherwise, guarantees in the nature of performance specifications furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us, if any, are subject to laboratory tests corrected for field performance. Any additional guarantees, in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative. Due to inaccuracies in field testing, if a conflict arises between the results of field testing conducted by or for user, and laboratory tests corrected for field performance, the latter shall control. Components or accessories supplied by us but manufactured by others are warranted only to the extent of and by the terms and conditions of the original manufacturer s warranty. RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN. This warranty shall not apply when damage is caused by (a) improper installation, (b) improper voltage, (c) lightning, (d) sand or other abrasive material, (e) scale or corrosion build-up due to excessive chemical content. Any modification of the original equipment will also void the warranty. We will not be responsible for loss, damage, or labor cost due to interruption of service caused by defective parts. Neither will we accept charges incurred by others without our prior written approval. This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice and/or our specific recommendations. The purchaser is responsible for communication of all necessary information regarding the application and use of the product. UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR ANY OTHER DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN MATERIAL AND/OR WORKMANSHIP AND/OR DAMAGE OR DELAYS IN SHIPMENT. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, without our prior written approval. If any litigation is commenced between the parties hereto for the enforcement of any rights hereunder, the successful party in subject litigation shall be entitled to receive from the unsuccessful party all costs incurred in connection therewith, including a reasonable amount for attorney s fees. YOUR ACCEPTANCE OF ANY GOODS SUPPLIED BY US, OR ON OUR BEHALF, SHALL, WITHOUT LIMITATION CONSTITUTE ACCEPTANCE OF ALL TERMS AND CONDITIONS STATED ABOVE. 420 Third St. P.O. Box 603 Piqua, Ohio Ph: (937) Fax: sellersclean@cranepumps.com
10
11
12
13
14
15
16
17
18
ASTech. Tank Man Index. 2 Nozzle Tank Man Performance curve Dimensional information Sectional view & parts list Operation and maintenance manual
ASTech APPLIED SPRAY TECHNOLOGY Tank Man Index 2 Nozzle Tank Man Performance curve Dimensional information Sectional view & parts list Operation and maintenance manual 3 Nozzle Tank Man Performance curve
More informationINSTALLATION AND OPERATION MANUAL. Condensate Return Systems - Series: GV
INSTALLATION AND OPERATION MANUAL Condensate Return Systems - Series: GV WARNING! The receiver tank is NOT a pressure vessel. It MUST be vented to atmoshere to prevent pressure buildup. Any internal pressure
More informationSUBMERSIBLE GRINDER PUMPS: MOTORS: FLOWS to 135 USGPM HEADS to 350 FT TDH SEMI-OPEN, MULTI-VANE, IMPELLER DUPLEX STAINLESS STEEL GRINDING MECHANISM
SUBMERSIBLE GRINDER PUMPS: DRY PIT WET PIT PORTABLE MOTORS: 2-POLE: 7.5-19 HP 4-POLE: 7.5 HP 230V-460V-575V/3PH/60HZ FLOWS to 135 USGPM HEADS to 350 FT TDH SEMI-OPEN, MULTI-VANE, IMPELLER DUPLEX STAINLESS
More informationINSTALLATION AND OPERATION MANUAL. In-Line Centrifugal Pumps - Series: GB
C A L L 1-866-670-0533 O R D E R O N L I N E www.burkspumpcatalog.com INSTALLATION AND OPERATION MANUAL In-Line Centrifugal Pumps - Series: GB IMPORTANT! Read all instructions in this manual before operating
More informationTERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)
TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for
More informationPortable Utillity Submersible Pump Model: UT17-1/6 Hp, 120 Volt, 60Hz, 1Ph
BARNES Portable Utillity Submersible Pump Model: UT17-1/6 Hp, 120 Volt, 60Hz, 1Ph SPECIFICATIONS DISCHARGE... 3/4 G.H.T. Male, Vertical LIQUID TEMPERATURE... 77 F (25 C) Continuous MOTOR HOUSING... Thermoplastic
More informationHR-20P Pneumatically Controlled Pressure Regulator
HR-20P Pneumatically Controlled Pressure Regulator Instruction and Service Manual Hydroplex Corporation 230 West Gloria Switch Rd. Lafayette, LA 70507 337-233-0626 www.hydroplexpumps.com I. General Instructions
More informationWatts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions
Watts Series CSM-61 Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 4, 5, 65 and 8mm) Installation Instructions IS-CSM-61-L Watts Measurement/Balancing Valves are available
More informationSTAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications
STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications Manufactured in ISO9000:2000 Facility Manufactured to ASTM/ASME A182/SA182 Items conform
More informationDual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev
Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How
More informationOperating and Maintenance Instructions
1500 Tube Leak Test Gun - Vacuum Tube & Pipe Cleaners Tube Testers Tube Plugs Tube Removal Tube Installation Operating and Maintenance Instructions www.elliott-tool.com Table Of Contents Introduction...
More informationOwner s Manual GLASSLINED PUMP TANK
Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that
More informationINSTALLATION AND OPERATION MANUAL. Self-Priming Centrifugal Pumps
C A L L 1-866 -670-0533 OR D E R O N L I NE www.burkspumpcatalog.com INSTALLATION AND OPERATION MANUAL Self-Priming Centrifugal Pumps Series WT For Water and Other 1.00 S.G. Fluids Series WPT For Perchlorethylene
More informationPENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material
More informationGen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB
Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB P-273-8 819-0531 Installation Instructions Vented Enclosed Version Optional An Altra Industrial Motion Company Warner Electric s
More informationFemale Plug. connecting to Fuel Quantity
**Ag Diesel Solutions recommends replacing the Transorb/Suppressor Diode before the installation of this module*** Red wire = 12V Constant power. Male Plug connecting to Fuel Quantity Valve Black wire
More informationWATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S
WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S 466 S. SKYLANE DR. DURANGO, COLORADO 81303 970-259-2869 PHONE 970-259-2868 FAX www.stoneagetools.com
More informationCompressor Clutch Replacement Procedure
Clutch Replacement Procedure P-1401-WE 819-0316 Installation Instructions An Altra Industrial Motion Company Warner Replacement Clutches for the following compressors: Denso 6E171 10P15 6P148 6C17 Ford
More informationInstallation & Operating Instructions for Zone Valve Boxes & Ball Valves
V Series Zone Valve Box EV Series Zone Valve Box Ball Valve Page 1 of 9 Introduction The Powerex ball valves and zone valve boxes are cleaned for use with oxygen. Each valve is tested for leakage in both
More informationINSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL BB15-12 12 Volt 1500 Watt Barnes Backup Systems IMPORTANT! Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant
More informationElectrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180
Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180 P-273-8-WE 819-0531 Installation Instructions Vented Enclosed Version Optional Warner Electric s MBFB series of Electrically
More informationManufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1
STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com
More information30100 Module Installation Guide L
30100 Module Installation Guide 1997-2006 12.0L Mack Engines Up to 30% HP Gain 10-20% Fuel Savings AgDieselSolutions.com 1997-2006 Mack 12.0L Engine Module +12 volts red wire. Ground black wire Injector
More informationTurbine Submersible Pumps
www.hydroflopumps.com Investment Cast Stainless Steel Impellers Turbine Submersible Pumps Hydroflo Pumps USA, Inc. 18 Loblolly Pine Blvd. Fairview, Tennessee 362 Phone: 615-799-9662 Fax: 615-799-5654 Hydroflo
More information20250 Module Installation Guide
20250 Module Installation Guide 2013.5-2017 RAM 6.7L Cummins Up to 90HP Gain 1-3 MPG Fuel Savings AgDieselSolutions.com Adjustable switch connector Power +12 volts (Red wire) & Ground (Black wire) Injector
More informationMercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions
1999-2006 Mercedes MBE 906/926 6.4L & 7.2L Engine Module Part # 15000 Installation Instructions 15000_revC 1999-2006 Mercedes 6.4L & 7.2L Engine Module +12 volts red wire. Ground black wire Injector Terminals
More informationAPCO ASR-400/450 SEWAGE AIR RELEASE VALVES
APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage
More informationSubmersible Waterfall Pump 1200 Gallons Per Hour
ITEM # LL1200 Submersible Waterfall Pump 1200 Gallons Per Hour REMINDER CALL 1-888-412-6001 EFORE RETURNING TO STORE. PACKAGE CONTENTS Questions, problems, missing parts? efore returning to your retailer,
More informationCU6703 Module Installation Guide
Up to 30% More Horsepower 10-20% Fuel Savings Cummins 6.7L Tier III Engines CU6703 Module Installation Guide AgDieselSolutions.com MAP sensor male and female connectors. Power and Ground wires. Module
More informationPVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables
PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria
More informationCustomer Support
Portable auxiliary air tanks owner's Manual aux05 aux05a aux10 WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581 TAbLe OF CONTeNTS INTROduCTION IntroductIon Important Safety InStructIonS components
More informationNor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves
Instructions Safety Messages These instructions are intended for personnel who are responsible for installation, operation and maintenance of your DeZURIK Actuator. All safety messages in the instructions
More informationUniversal Bevel Drives Service Manual
Engineering Service Bulletin #SB241202 Universal Bevel Drives Service Manual Cautions Following are some general cautions. All personnel shall use safe and sound practices and take all necessary precautionary
More information15100 Module Installation Guide Mercedes EPA07 w/dpf
15100 Module Installation Guide 2007-2009 Mercedes EPA07 w/dpf 7.2L Engines Up to 30% HP Gain 10-20% Fuel Savings AgDieselSolutions.com 2007-2009 Mercedes 7.2L Engine Module +12 volts red wire. Ground
More informationDeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators
AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators Instructions D11033 August 2013 Instructions These instructions provide information about AFR3 Filter Regulators. They are for use by personnel
More informationSeries: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps
INSTALLATION MANUAL Series: 1/12HP, 5000 RPM, 60 Hz ISP No: - 6/09 General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information
More informationDAP-625S and DAP-875S
AIR CHAMP PRODUCTS DAP-625S and DAP-875S (i) FORM NO. L-20078-B-0501 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject
More informationCummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200
1994-2003 Cummins N14 Celect & Celect Plus Engine Module For Agricultural Applications Only Part # 31200 31200_revA Adjustable Switch Agricultural Cummins N14 Engine Module Power and Ground terminals Timing
More informationInstallation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of
More informationALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase
ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL AL- Model Number Date Code / Serial Number Date of Purchase LIMITED WARRANTY ALITA warrants to the original retail consumer purchaser ( Customer ) that
More informationUtility Controller Hand Air Operated
Utility Controller Hand Air Operated P-1395 819-0288 Installation Instructions Introduction The Warner Electric air/manual Utility Controller combines manual and automatic (air) actuation for the operation
More informationInstruction Manual for Operation & Maintenance
Instruction Manual for Operation & Maintenance BigSprinkler.com 15250 Sunshine Rd. Yukon, OK. 73099 1-855-805-7901 Introduction Thank you for purchasing a ReelGreen RG25 Traveling Sprinkler System. Please
More informationAMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016
AMES 2016 Price List Backflow Prevention Products and Repair Kits and Parts Effective February 29, 2016 All prices supersede previous issues, are temporary and subject to change without notice. AmesFireWater.com
More informationERD Electrically Released Brakes
ERD Electrically Released Brakes P-229 819-0453 Installation Instructions Warner Electric s ERD series spring set, electrically released brakes are designed to hold a load when the power to the brake is
More informationNatural Fiber Planter Fountain
Natural iber Planter ountain REMINDER CALL 1-888-755-5641 BEORE RETURNING TO STORE. PACKAGE CONTENTS Questions, problems, missing parts? Before returning to your retailer, call our customer service department
More informationElgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704
Elgin Hydraulic Clutch-Brake ECB-20, Product Number 96225 FORM NO. L-20283-F-070 1 FORM NO. L-20283-F-070 In accordance with Nexen s established policy of constant product improvement, the specifications
More informationMODEL 200 MULTI-JET FLOW METER
MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Technical Toll-Free: 877.722.4631 Sales Toll-Free: 800.235.1638
More informationFranklin Fueling Systems
Submersible Pumping and Fuel Management Systems Limited Warranty - FE Petro and INCON Fueling Systems Limited Warranties. 90-Day Warranty Coverage (Applicable Only to Tank Gauge Software, OEM Equipment
More informationElectrically Released Motor Brake Module for EM-MBFB and EUM-MBFB
Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB P-1337-WE 819-0314 Installation Instructions An Altra Industrial Motion Company Warner Electric s MBFB series of Electrically Released
More informationCompressor Clutch Replacement Procedure
P-1411 819-0361 Compressor Clutch Replacement Procedure Installation Instructions World Clutch with Unidamp Armature for Ford FX-15 and FS-10 Compressors and all Denso Models with 30mm bearing fit. Keep
More informationLUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type
INSTRUCTIONS-PARTS LIST 306 460 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. E Supercedes D Detachable-type LUBRICATOR GUN 10,000 psi (700 bar)
More informationSHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)
SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS) GENERAL SHAW-BOX Rigid Mount I-Beam Trolleys are designed
More informationGM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com
21700 Module Installation Guide 2017 GM 6.6L Duramax *L5P* Up to 90HP Gain 1-3 MPG Fuel Savings AgDieselSolutions.com Adjustable Switch Female Fuel Pressure Sensor Connector Male Fuel Pressure Sensor Connector
More informationWARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN
WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter
More informationCaution. Do not operate your Micro Rain traveler without a serious overview of this manual. Keep children and unauthorized people away from traveler
Thank you for purchasing a Micro Rain MR25 traveling sprinkler system. Please read this manual carefully before operation in order to become familiar with all components and their function. Safety is the
More informationStormPro BA Series Sump Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More informationTHE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.
Series 909 Reduced Pressure Zone Backflow Preventers Sizes: 3 /4" 2" (20 50mm) Installation Service Repair Kits Maintenance No. 1 1 2" shown Patent Number 4,241,752 IMPORTANT: Inquire with governing authorities
More informationDeZURIK 2 20" BOS BUTTERFLY VALVES
2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are
More informationOpen Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Open Display Merchandiser Installation and Operation Manual Please read this manual completely
More informationSeries 2100 Operating Instructions
Series 2100 Operating Instructions Installation Instructions Visit the link below or scan the QR code to watch a detailed installation video: http://triteqlock.com/fresh After the lock, temperature probe,
More informationCrescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS
Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS Reference Manual FM-300 Series Copyright 2005 Nova Controls, Inc. P/N 20-08195-00 Rev. B i ii 1 Description Overview The FM-300 series Flush Manifold
More informationPremium Pond Pump 330 Gallons Per Hour
Premium Pond 330 Gallons Per Hour REMINDER CALL 1-888-755-4497 BEFORE RETURNING TO STORE. MODEL #PDP330 Questions, problems, missing parts? Before returning to your retailer, call our customer service
More informationSingle-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)
Single-Position Detent Clutch DC Series (i) FORM NO. L-2017-A-001 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject
More informationJDCR2000 Module Installation Guide
Up to 30% More Horsepower 10-20% Fuel Savings John Deere 4.5L, 8.1L & 9.0L Tier III Denso Common Rail Engines JDCR2000 Module Installation Guide AgDieselSolutions.com FEMALE FUEL PRESSURE CONNECTOR (FPC)
More informationPVI 60KW, PVI 82KW, PVI 95KW
PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy
More informationINSTALLATION MANUAL & START UP Control Panel
BARNES INSTALLATION MANUAL & START UP Control Panel IMPORTANT! Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program,
More informationReference Manual FM-200 Series
Flush Manifold A/P FOR LIQUID LAUNDRY SUPPLY SYSTEMS Reference Manual FM-200 Series Copyright 2004 Nova Controls, Inc. P/N 20-07941-00 Rev. C i P/N 20-07941-00 Rev. C ii P/N 20-07941-00 Rev. C 1 Description
More informationMODEL 200 MULTI-JET FLOW METER
MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155
More informationPrice List. Backfl ow Prevention Products, Repair Kits, and Parts. Effective July 2, AmesFireWater.com 2018 AMES FIRE & WATERWORKS PRICE LIST
2018 AMES FIRE & WATERWORKS PRICE LIST Price List Backfl ow Prevention Products, Repair Kits, and Parts Effective July 2, 2018 All prices supersede previous issues, are temporary and subject to change
More informationDRAIN WATER TEMPERING KIT
INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR FOR USE WITH SH(X) GAS FIRED HUMIDIFIER OUTDOOR MODELS CANADIAN HEAD OFFICE AND FACTORY 1401 HASTINGS CRES. SE CALGARY, ALBERTA T2G 4C8 Ph: (403) 287
More informationMODEL 900 IMPELLER-TYPE FLOW METER
MODEL 900 IMPELLER-TYPE FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155
More informationBC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO
MEX (55) 5 6 QRO (44) 95 7 60 MTY () 54 0 BC Brake Caliper (i) FORM NO. L-0066-B-040 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this
More informationInstallation Instructions
85-4592 rev. 08 02-18 Installation Instructions Thank you for purchasing our sway bar kit. Please read through these instructions before installation. Auxiliary Rear Anti-Sway Bar Kit for Ford F53 part
More informationGA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)
INSTALLATION, OPERATION AND MAINTENANCE MANUAL LUDLOW SERIES FIGURE 350-W 3 to 30 Lever & Weight Air-Cushioned Swing Check Valves TABLE OF CONTENTS Introduction. 1 Description of Operation... 1 Receiving
More informationINSTALLATION MANUAL Basement GENIE
BARNES INSTALLATION MANUAL Basement GENIE Series: BGB BGBSE411 BGBSEV412 IMPORTANT! Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product
More informationOMNI GEAR TRACTOR POWERED IMPLEMENT GEARDRIVES
TRACTOR POWERED IMPLEMENT GEARDRIVES PHD-15 Series 1750 lb.-in. 198 Nm. Ratios: 3:1 Tapered, Ball, Needle Oil Cap: 25 oz. (0.7 L) 26 lbs. (11.8 kg) Power: 15 hp 11 kw Post Hole Digger Drives PHD-25 Series
More informationSGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement
SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement This Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement (the Agreement ) is entered
More informationContainer Fountain Kit with LED Light
Container Fountain Kit with LED Light REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS Questions, problems, missing parts? Before returning to your retailer, call our customer service
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )
012 Mech 07.11 OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More information60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60
60 PSI Boost Gauge For Product Numbers: MT-DV01_60, MT-WDV01_60 Red: 12v Constant (un-switched) Source (+) Orange: 12v Dimmer (switched) Source (+) (optional) White: 12v Ignition (switched) Source (+)
More information10 Year Limited Warranty
Power. On Your Terms. 10 Year Limited Warranty PHI 2.7 TM PHI 3.5 TM 60A SIMPLIPHI POWER, INC. REV020618 10 Year Limited Warranty: PHI 2.7 TM PHI 3.5 TM 60A 24V 48V Limited Pro-Rated Warranty Coverage
More informationA/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT
A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS Do not attempt to clean or inspect anything while the engine is running. Cleaning and inspection must be done by a certified mechanic. All A/C service must
More informationGen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180
Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180 P-273-4 819-0528 Installation Instructions Vented Enclosed Version Optional An Altra Industrial Motion Company Contents Mounting to a C-Face Motor........3
More informationPreassembled Clutch/Brake Module
Preassembled Clutch/Brake Module P-273-1-WE 819-0343 Installation Instructions An Altra Industrial Motion Company Contents MountingtoaMotor...3 Mounting to a Reducer.............3 Installing the Base Mount...........4
More informationPOWER GEAR SLIDE-OUT MANUAL
POWER GEAR SLIDE-OUT MANUAL Operation Guide FLUSH FLOOR SLIDE-OUT SYSTEM FOR AMERICAN COACH PRODUCTS 82-S0220-01 Rev. 1 AMERICAN COACH SLIDE-OUT MANUAL FLUSH FLOOR SYSTEM TABLE OF CONTENTS SECTION PAGE
More informationPremium Waterfall Pump 1200 Gallons Per Hour
Premium Waterfall 1200 Gallons Per Hour REMINDER CALL 1-888-755-4497 BEFORE RETURNING TO STORE. MODEL #PWP1200 Questions, problems, missing parts? Before returning to your retailer, call our customer service
More informationASSEMBLY OF TROLLEY TO HOIST
INSTRUCTIONS AND PARTS LIST RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS) GENERAL Yale Rigid Mount I-Beam Trolleys are designed especially for use on
More informationREAD THIS MANUAL CAREFULLY BEFORE USING THE PUMP
OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This
More informationMechanical Filter Pump Kit Up to 500 gallons
Mechanical Filter Pump Kit Up to 500 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. ITEM #FM002P Questions, problems, missing parts? Before returning to your retailer, call our customer
More informationProcedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub
Procedure to Install the New Autogap components in ER-15 and ER85 Brake with inverted P-30-1 819-0376 Installation & Operating Instructions Contents Introduction........................... Kit Parts List..........................
More informationAquaSense TM ZTS6200EV Series
AquaSense TM EV ZTS6200EV Series Automatic Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance, and Parts Manual Patented and Patents Pending ZTS6200EV Flushometer for Water
More informationService & Installation Instructions. An Altra Industrial Motion Company P WE Vented. Enclosed Version Optional
Gen 2 Electro-Module EM-50, EM-100, EM-180 Electrically Released Permanent Magnet Brake Module EM-50-20FBB, EM-100-20FBB, EM-180-20FBB EM-50-20FBC, EM-100-20FBC, EM-180-20FBC P-273-5-WE 819-0529 Service
More informationInstallation Instructions
Gen 2 Electro-Module EM-50, EM-100, EM-180 Electrically Released Permanent Magnet Brake Module EM-50-20FBB, EM-100-20FBB, EM-180-20FBB EM-50-20FBC, EM-100-20FBC, EM-180-20FBC P-273-5 819-0529 Installation
More informationAT Clutch Major Service Sizes 25, 55, 115
P-1404 819-0324 AT Clutch Major Service Sizes 25, 55, 115 Installation Instructions Contents Introduction............................ 2 Warranty....................... back cover Failure to follow these
More informationLevel Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions
Level Alert Model 2000 Multi-Switch Liquid Level Sensor Assembly and Installation Instructions Kit Form Each unit is provided in kit form with step-by-step instructions, making it extremely easy to custom
More informationActuLink ABS Module - ABS-MOD-400
Installation Instructions ActuLink ABS Module - ABS-MOD-400 For more information on the installation and operation of Tuson s towable ABS system, consult the installation and operations manuals for the
More informationElectromagnetic Particle Brakes Model: PRB-H
P-223-3 819-0370 Electromagnetic Particle Brakes Model: PRB-H Installation Instructions Table of Contents Introduction............................2 Installation Instructions....................3 Start
More informationFlo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide
Flo-Way R Solids Impact Flow Meter Measure Granular or Powdered Material Stand Alone or Connect to Other Devices for Blending Used by Successful Producers World-Wide Visit our website: www.beltwayscales.com
More informationCBC-160-1N and CBC-160-2N Clutch/Brake Controls
P-239-36 819-04 CBC-160-1N and Clutch/Brake Controls Installation Instructions An Altra Industrial Motion Company Contents Introduction...2 Specifications........................... 2 Installation...3
More informationINSTALLATION AND OPERATION MANUAL SELF-PRIMING CENTRIFUGAL PUMPS
Form No. 101720 REV. B 420 Third Street Piqua, Ohio 45356-0603 Phone: (937) 778-8947 Fax: (937) 773-7157 www.burkspumps.com INSTALLATION AND OPERATION MANUAL SELF-PRIMING CENTRIFUGAL PUMPS Models: 1-1/2"
More information