INSTALLATION, OPERATION & MAINTENANCE MANUAL BLOWN FILM COOLER BERG

Size: px
Start display at page:

Download "INSTALLATION, OPERATION & MAINTENANCE MANUAL BLOWN FILM COOLER BERG"

Transcription

1 INSTALLATION, OPERATION & MAINTENANCE MANUAL BLOWN FILM COOLER BERG

2 For 24 hour service inquiries, Please call (416) BERG SERIES BLOWN FILM COOLER Page 2

3 BLOWN FILM COOLER INSTALLATION, OPERATION & MAINTENANCE MANUAL CONTENTS Section Description 1.0 Introduction 2.0 Uncrating 3.0 Location 4.0 Installation 5.0 Installation-Check 6.0 Start-Up 7.0 Operation 8.0 Not applicable to this equipment 9.0 Not applicable to this equipment 10.0 Troubleshooting 11.0 Maintenance 12.0 Recommended Spare Parts List 13.0 Warranty 14.0 Component Specifications BERG SERIES BLOWN FILM COOLER Page 3

4 1.0.0 INTRODUCTION On behalf of everyone at Berg Chilling Systems, thank you for purchasing this equipment. With over 35 years experience in developing and implementing customized Process Cooling solutions for customers around the world, we firmly believe that our equipment is second to none and that the solution provided for you in this equipment has been engineered and manufactured using only the highest quality, state of the art components, to give trouble free service with a minimum of maintenance. Our commitment to your satisfaction is extended through our Parts and Labour warranty as outlined at the back of this manual. It is in everyone s best interest if you read this manual thoroughly and where applicable, familiarize yourself with the checklists and tips contained here, and adhere to the safety and maintenance schedules outlined. Proper care and attention to maintenance and operating procedures will ensure an extended service life and minimum downtime of your equipment Your unit is self-protected by a series of safety controls integrated in the control system. These have been finely set to obtain both adequate protection and optimum efficiency from your unit Before you start to install your unit, we urge you to carefully read through and digest this literature to familiarize yourself with its contents. BERG SERIES BLOWN FILM COOLER Page 4

5 2.0.0 UNCRATING AND CHECKING UNIT FOR DAMAGE Remove packaging material and examine unit for shipping damages. The consignee is responsible for making claims to the transportation agent and any damage should be reported immediately Also report any damage to BERG. BERG SERIES BLOWN FILM COOLER Page 5

6 3.0.0 LOCATION OF UNIT It is recommended that the blown film cooler be located horizontally to allow for proper drainage (see Figure 1) The tank assembly must be located inside a building that is heated (minimum room temperature of 50ºF) during the winter months Adequate clearance is necessary for the removal of the filter(s) and/or the cooling coil from the blown film cooler housing (see figure 3) The unit should be located close to the air ring and clearance should be allowed for necessary ductwork and hoses. Figure 1: Drain Connection BERG SERIES BLOWN FILM COOLER Page 6

7 4.0.0 INSTALLATION The unit should be firmly fastened to the floor (or to some part of the steel structure forming the tower) Make the water connections from the portable chiller, central chilling system, or from city water. The BERG unit comes with a gate valve at the inlet and a ball valve at the outlet Maintain full line sizes for both supply and return lines unless the lines are extremely long Connect the existing fan to the blown film cooler air inlet. Connect the blown film cooler air outlet to the air ring through a proper distribution of header and hoses A 1 FPT drain connection is provided at the bottom of the housing. A P-Trap or a condensate trap must be installed to remove the condensate that collects during cooling. The P-Trap must be high enough to form a proper seal (see Figure 1) It is recommended that the discharge hose and air distribution system, including the air ring, be insulated. This is to obtain optimum efficiency and to prevent condensation on the cold surfaces. The chilled fluid lines should also be insulated. Before proceeding with the insulation, check the system for water and air leaks. BERG SERIES BLOWN FILM COOLER Page 7

8 4.6.0 Supply and return piping should be adequately sized to minimize pressure losses. The following chart can be used as a guideline for selecting pipe sizes. PIPE DIAMETER (inches) MAX. FLOW RATE (usgpm) 3/ / / / These capacities are based on Sch40 black pipe with an approximate pressure loss of 10 ft. per 100 ft. of pipe length For pipe runs 200 ft. or longer, it may be necessary to oversize the pipe. Check with your BERG representative. BERG SERIES BLOWN FILM COOLER Page 8

9 5.0.0 INSTALLATION CHECK Your installation is now complete. Do not switch unit on. Make a complete visual check of unit for damage sustained during installation Check all terminal screws in control panel making sure they are tight Check all Inlet and discharge piping connections making sure they are watertight and leak proof You are now ready for start up. BERG SERIES BLOWN FILM COOLER Page 9

10 6.0.0 START-UP PROCEDURE Inspect all pipe connections for proper fit Check that all pipe supports are secure Check all electrical connections to ensure they are tight Verify that the line voltage agrees with the voltage on the electrical nameplate Make sure that the blown film cooler s water supply and return valves are open Make sure that the chiller or chiller system is in operation. BERG SERIES BLOWN FILM COOLER Page 10

11 7.0.0 OPERATING INSTRUCTIONS Manual Operation Where a separate chiller is used, adjust the chiller temperature until the required air temperature is achieved (usually 5ºFlower). For example, if the required air temperature is 55ºF, the chiller should be adjusted to provide 50ºF water Where a central system is used, and it is not possible to adjust the temperature of the fluid, it will be necessary to throttle the flow by adjusting the ball valve at the coil outlet Automatic Operation If possible, operate the chiller at 5ºF lower than the required air temperature. This will provide maximum efficiency. Do not operate with a solution temperature lower than 32ºF. At this temperature, the condensate will begin to freeze on the coil. This will cause a drop in capacity, an increase in velocity, moisture carry-over, a reduction in airflow, and eventually a frozen coil would result Allow the unit to reach equilibrium conditions. If required, adjust the three-way valve. Refer to attached instruction book Allow the unit to reach equilibrium conditions again. Adjust again as needed To raise the control point, turn from left to right. To lower the control point, turn from right to left. The figures on the scale are for reference and represent the approximate location of the set point within the range. BERG SERIES BLOWN FILM COOLER Page 11

12 8.0 THIS SECTION IS BLANK. BERG SERIES BLOWN FILM COOLER Page 12

13 9.0 THIS SECTION IS BLANK. BERG SERIES BLOWN FILM COOLER Page 13

14 10.0 THIS SECTION IS BLANK. BERG SERIES BLOWN FILM COOLER Page 14

15 12.0 Recommended Spare Parts List BERG SERIES BLOWN FILM COOLER Page 15

16 Limited Warranty Berg Chilling Systems Inc. ( Berg ) warrants to Buyer that upon delivery to Buyer the Products purchased hereunder shall conform to the applicable Seller s specifications as provided in the quotation. Except as are contained herein, Berg makes no warranties, conditions, guarantees or representations relating to the Products, express or implied, statutory or otherwise. The Seller warrants all Products it manufactures to be free from defects in workmanship and material when used under conditions recommended by us. The Seller s obligation under the warranty is limited to repair or replace or otherwise make good, at our factory, any parts which, within one year after date of shipment of equipment of our manufacture to the original purchaser, after being returned to us with transportation prepaid, and upon our examination, shall disclose to our satisfaction to have been defective. The Seller neither assures, nor authorizes any other persons to assume for us, any liability in connection with the sales of our equipment except under the conditions of this warranty. The warranty does not cover any field (on site) labour charges for replacement of parts, adjustment, repairs, or any other work done. This warranty shall not apply to any Product or apparatus which in our opinion has been subject to misuse, negligence, or pressures in excess of limits recommended by us, or which have been repaired or altered outside Berg s factory or which have had the serial number(s) removed or defaced. This warranty does not cover refrigerant gas, nor does it cover any apparatus damaged from freezing of water or heat transfer fluid. Replacement or repair of defective material will be EX WORKS our factory, and will assume any used portion of this warranty. All defective parts become the property of Berg and must be returned within fifteen (15) days of the replacement date, transportation prepaid, as advised by Berg, to become eligible for replacement under this warranty. Warranty Claim Forms, found in the Product Owner s Manual, must accompany all warranty claims and parts returns or this warranty shall not apply. Berg is not responsible for any sales, use, excise, duty or any other applicable taxes associated with the replacement of parts under this warranty. This warranty is only effective with all the terms and conditions of the Product quote being met, and it is understood that time is of the essence in this agreement. Repair or replacement of products not of our manufacture will be limited to the warranty of the manufacturers of such products. Seller shall transfer to Buyer whatever transferable warranties and indemnities Seller receives from the manufacturers of any subcomponents of the Products, if any, including any transferable warranties and indemnities in respect of patent infringement. See the Product Service Labour Policies in your Product Owner s Manual for possible extensions to this Warranty. This is an expressed warranty of merchantability and or fitness for a particular purpose; all other implied warranties and any liabilities not based upon contract are hereby disclaimed and excluded by this warranty. In accordance with Section 7 of our Standard Terms and Conditions of Sale, under no circumstances shall Berg Chilling Systems Inc. be liable for loss of prospective or speculative profits, or special, indirect, incidental, or consequential damages. This warranty is a part of the Standard Terms and Conditions of Sale of Berg Chilling Systems Inc. BERG SERIES BLOWN FILM COOLER Page 16

17 Service Labour Policy Berg s Service Labour Policy extends the One (1) Year Limited Warranty to include labour on a limited basis, to the original purchaser only (see the Limited Labour Allowance Schedule in your Product Owner s Manual for allowable service hours). Berg will provide a Service Technician or reimburse the Buyer in accordance with this Policy, to diagnose the problem, repair or replace or otherwise make good, any part of equipment of our manufacture, which within one year after the date of shipment to a destination within Canada or continental United States of America ( the Territory ), and upon our examination, shall disclose to our satisfaction to have been defective. If the Product or equipment is located outside the Territory, our limited warranty only, ex works our factory, shall apply for one year from the date of shipping (see Standard Terms and Conditions of Sale). Berg neither assures, nor authorizes any other persons to assume for us, any liability in connection with the sale of our equipment except under the conditions of this Policy. This Service Labour Policy does not apply to Temperature Control Units (TCU s). The Service Labour Policy does not cover any field (on site) labour charges during overtime hours (5:00pm to 8:00am or during weekends and holidays) nor does it cover charges, labour or otherwise, associated with travel and accommodation, adjustments and maintenance, or work done outside of Canada and continental USA. Any cost differential for overtime labour charges will be the responsibility of the Buyer. Service Labour rates applied to the Limited Labour Allowance Schedule, will be the mean rate, as determined by Berg, of the equipment destination service area. This Policy is voided and shall not apply if in our opinion, the Product has been subject to misuse, negligence, or pressures in excess of limits recommended by Berg, or which have been repaired or altered outside Berg s factory or authorization or which have had the serial number(s) removed or defaced. This Policy does not cover refrigerant gas or any labour associated with its evacuation or replacement nor does it cover any Product or apparatus maintenance or any apparatus damaged from freezing of water or heat transfer fluid. Any work determined to be associated with the above will be the responsibility of the Buyer. Berg is not responsible for any sales, use, excise, duty or any other applicable taxes associated with the replacement of parts or labour under this Policy. This Policy is only effective with all the terms and conditions of our quote being met, and it is understood that time is of the essence in this agreement. This Policy is not transferable. All Service Policy Labour must be authorized by Berg prior to any work being performed and must have a Berg Purchase Order issued specifically for the work. Warranty and Service Labour Claim Forms, found in the Product Owner s Manual, must accompany all Service and Warranty claims and parts returns or this Policy shall not apply. All defective parts become the property of Berg and must be returned within fifteen (15) days of the failure, transportation prepaid, as advised by Berg, to become eligible for replacement under this policy. Products not of our manufacture do not qualify for this Service Labour Policy, and will be limited to the warranty of the manufacturers of such Products. This Policy is a part of the Standard Terms and Conditions of Sale of Berg Chilling Systems Inc. BERG SERIES BLOWN FILM COOLER Page 17

18 Warranty Claim Procedure Labour warranty, will only be allowed in those situations where defects have occurred as a direct result of factory workmanship or defects in materials. Claim Procedures: Consult the Factory immediately of any problems you are having with your equipment. Phone or fax If required Berg will supply contact information for the local authorized Berg Service Contractor in your area; or if you wish you can use your own contractor, provided he is licensed and qualified as required by local governing authorities and it is agreed upon by Berg. After the contractor has arrived on site and determined the cause of the problem; the contractor must consult with the factory before proceeding with any repairs. Once you have had your equipment repaired, complete the Warranty Claim Form. All claims must be submitted on the Warranty Claim Form found in the owners manual. A signed service report from the Contractor detailing all work performed and an invoice copy must accompany the Warranty Claim Form. Claims must be faxed to Berg Service no later than 15 days after the failure has occurred. Claims in excess of the Limited Labour Allowance Schedule may not be processed. Berg reserves the right to adjust and/or refuse any claims that appear excessive or fails to meet the Claims Procedure. No claims will be processed if defective parts are not returned to Berg prepaid. Use the Limited Labour Allowance Schedule [found in the owners manual] as a guide to calculate the amount Berg will reimburse for required repairs on equipment found to be defective. The schedule shows the maximum man-hours, which will be reimbursed at the normal hourly rate of $54.00/Hr. Berg will not pay for: Labour at overtime or premium rates Labour in excess of the Limited Labour Schedule Service charges, mileage, travel expenses of any kind Miscellaneous materials Freight Taxes or any special fees BERG SERIES BLOWN FILM COOLER Page 18

19 Service Labour Claim Procedures Using the Limited Labour Allowance Schedule [above] as a guide to calculate the amount Berg will reimburse for required repairs to equipment found to be defective. This schedule shows the maximum man-hours, which will be reimbursed at the normal hourly rate of $54.00/Hr. Labour warranty, will only be allowed in those situations where defects have occurred as a direct result of factory workmanship or materials. Claim Procedures: All claims must be submitted on Berg s Warranty Claim Form. Claim forms are found in the equipment owners manual or can be supplied upon request. If a contractor is used to make the repairs, a signed service report and a company invoice must accompany the Warranty Claim Form. Claims must be faxed to Berg Service no later than 15 days after the failure has occurred. Claims in excess of the Limited Labour Allowance Schedule will not be processed. BERG SERIES BLOWN FILM COOLER Page 19

20 Warranty Claim Form Fax to: Berg Service Dept Claim #: Date: Claim Submitted By: Company: Address: Job Name: Address: Phone #: Phone #: Fax #: Fax #: Berg Model #: Date of Failure: Voltage: Serial #: Date of Original Start-Up: Details of Failure Describe the nature of the failure. Part Number(s) [if applicable] Quantity Cost for Repairs Requesting: Repair Replace Reimbursement Other Total: To qualify for Limited Labour Warranty, you must include a signed service report and a copy of the contractor s invoice. Attached: Yes: No: Do not write below this line. Date Form Received: Warranty Claim Form Being Handled By: Note: All defective parts must be returned prepaid and within 15 days of the failure date. No credit will be issued if the defective parts are not returned prepaid and within the specified time allowed. BERG SERIES BLOWN FILM COOLER Page 20

21 LIMITED LABOUR ALLOWANCE SCHEDULE DESCRIPTION OF FAILED COMPONENT SIZE IN HP MAX. ALLOWANCE MAN HOURS REPAIR REPLACE Compressor 3-10 HP HP HP Over 40 HP Leaks All 2 2 Electrical Wiring, Controls, Microprocessors Refrigerant Valves or Components All 1 2 All 1 2 Motors and Up /2 4 Pumps All 2 3 MAX. ALLOWABLE MAN HOURS Diagnostic 1 Miscellaneous 1 BERG SERIES BLOWN FILM COOLER Page 21

22 SERIAL PLATE & EQUIPMENT IDENTIFICATION A serial plate like the one shown below has been affixed to the apparatus, and it gives the following information: (example of Serial Plate) Whenever using this manual, check first that the serial number on the inside cover is identical to that on the serial plate of the equipment. In all correspondence with BERG, please refer to the manufacturing serial number, for true identification of the equipment. Whenever contacting BERG, be sure to state the manufacturing serial no.(s), and model no.(s). BERG SERIES BLOWN FILM COOLER Page 22

23 PRESSURE BLOWERS TYPE HP PRESSURE BLOWERS FANs 977, 125, Product/Technical Bulletin 7150 Issue Date 1295 A WORD ABOUT SAFETY The above WARNING decal appears on all nyb fans. Air moving equipment involves electrical wiring, moving parts, sound, and air velocity or pressure which can create safety hazards if the equipment is not properly installed, operated and maintained. To minimize this danger, follow these instructions as well as the additional instructions and warnings on the equipment itself. All installers, operators and maintenance personnel should study AMCA Publication 410, Recommended Safety Practices for Air Moving Devices, which is included as part of every shipment. Additional copies can be obtained by writing to New York Blower Company, 7660 Quincy St., Willowbrook, IL ELECTRICAL DISCONNECTS Every motor driven fan should have an independent disconnect switch to isolate the unit from the electrical supply. It should be near the fan and must be capable of being locked by maintenance personnel while servicing the unit, in accordance with OSHA procedures. MOVING PARTS All moving parts must have guards to protect personnel. Safety requirements vary, so the number and type of guards needed to meet company, local and OSHA standards must be determined and specified by the user. Never start a fan without having all safety guards installed. Check regularly for damaged or missing guards and do not operate any fan with guards removed. Fans can also become dangerous because of potential windmilling, even though all electrical power is disconnected. Always block the rotating assembly before working on any moving parts. BERG SERIES BLOWN FILM COOLER Page 23

24 SOUND Some fans can generate sound that could be hazardous to exposed personnel. It is the responsibility of the system designer and user to determine sound levels of the system, the degree of personnel exposure, and to comply with applicable safety requirements to protect personnel from excessive noise. Consult nyb for fan sound power level ratings. AIR PRESSURE AND SUCTION In addition to the normal dangers of rotating machinery, fans present another hazard from the suction created at the fan inlet. This suction can draw materials into the fan where they become high velocity projectiles at the outlet. It can also be extremely dangerous to persons in close proximity to the inlet, as the forces involved can overcome the strength of most individuals. Inlets and outlets that are not ducted should be screened to prevent entry and discharge of solid objects. ACCESS DOORS The above DANGER decal is placed on all nyb cleanout doors. These doors, as well as access doors to the duct system, should never be opened while the fan is in operation. Serious injury could result from the effects of air pressure or suction. Bolted doors must have the door nuts or fasteners securely tightened to prevent accidental or unauthorized opening. RECEIVING AND INSPECTION The fan and accessories should be inspected on receipt for any shipping damage. Turn the wheel by hand to see that it rotates freely and does not bind, If dampers or shutters are provided, check these accessories for free operation of all moving parts. FOB. factory shipping terms require that the receiver be responsible for inspecting the equipment upon arrival. Note damage or shortages on the Bill of Lading and file any claims for damage or loss in transit. nyb will assist the customer as much as possible; however, claims must be originated at the point of delivery. HANDLING AND STORAGE Fans should be lifted by the base, mounting supports, or lifting eyes only. Never lift a fan by the wheel, shaft, motor, motor bracket, housing inlet, outlet, or any fan part not designed for lifting. A spreader should always be used to avoid damage. On a direct drive Arrangement 8 fan, lifting holes are provided in the motor base to assist in handling the fan assembly. These lifting holes should be used in conjunction with the lifting eyes when lifting and positioning the fan onto its foundation. A heavy round steel bar or appropriate fixture can be passed through the lifting holes to simplify attachment of the lifting device. Be sure to follow all local safety codes when moving heavy equipment. BERG SERIES BLOWN FILM COOLER Page 24

25 Whenever possible, fans and accessories should be stored in a clean, dry location to prevent rust and corrosion of steel components. If outdoor storage is necessary, protection should be provided. Cover the inlet and outlet to prevent the accumulation of dirt and moisture in the housing. Cover motors with waterproof material. Refer to the bearing section for further storage instructions. Check shutters for free operation and lubricate moving parts prior to storage. Inspect the stored unit periodically. Rotate the wheel by hand every two weeks to redistribute grease on internal bearing parts. FAN INSTALLATION nyb wheels are dynamically balanced when fabricated. Complete assembled fans are test run at operating speeds to check the entire assembly for conformance to nyb vibration limits. Nevertheless, all units must be adequately supported for smooth operation. Ductwork or stacks should be independently supported as excess weight may distort the fan housing and cause contact between moving parts. Where vibration isolators are used, consult the nyb certified drawing for proper location and adjustment. Slab-Mounted Units A correctly designed and level concrete foundation provides the best means of installing floor-mounted fans. The mass of the base must maintain the fan/driver alignment, absorb normal vibration, and resist lateral loads. The overall dimensions of the concrete base should extend at least six inches beyond the base of the fan. The weight of the slab should be two to three times the weight of the rotating assembly, including the motor. The foundation requires firmly anchored fasteners such as the anchor bolts shown in Figure 1. Move the fan to the mounting location and lower it over the anchor bolts, leveling the fan with shims around the bolts. Fasten the fan securely. When grout is used, shim the fan at least 3/4-inch from the concrete base. (See Figure 1.) When isolation is used, check the nyb certified drawing for installation instructions. Elevated Units When an elevated or suspended structural steel platform is used, it must have sufficient bracing to support the unit load and prevent side sway. The platform should be of welded construction to maintain permanent alignment of all members. BERG SERIES BLOWN FILM COOLER Page 25

26 V-BELT DRIVE Installation 1. Remove all foreign material from the fan and motor shafts. Coat shafts with machine oil for easier mounting. Mount the belt guard backplate at this time if partial installation is required prior to sheave mounting. 2. Mount sheaves on shafts after checking sheave bores and bushings for nicks or burrs. Avoid using force. If resistance is encountered, lightly polish the shaft with emery cloth until the sheave slides on freely. Tighten tapered bushing bolts sequentially so that equal torque is applied to each. 3. Adjust the motor on its base to a position closest to the fan shaft. Install belts by working each one over the sheave grooves until all are in position. Never pry the belts into place. On nyb packaged fans, sufficient motor adjustment is provided for easy installation of the proper size belts. 4. Adjust sheaves and the motor shaft angle so that the sheave faces are in the same plane. Check this by placing a straightedge across the face of the sheaves. Any gap between the edge and sheave faces indicates misalignment. Important: This method is only valid when the width of the surface between the belt edge and the sheave face is the same for both sheaves. When they are not equal, or when using adjustable-pitch sheaves, adjust so that all belts have approximately equal tension. Both shafts should be at the right angles to the center belt. Belt Tensioning 1. Check belt tension with a tensioning gage and adjust using the motor slide base. Excess tension shortens bearing life while insufficient tension shortens belt life, can reduce fan performance and may cause vibration. The lowest allowable tension is that which prevents slippage under full load. Belts may slip during start-up, but slipping should stop as soon as the fan reaches full speed. For more precise tensioning methods, consult the drive manufacturer s literature. 2. Recheck setscrews, rotate the drive by hand and check for rubbing, then complete the installation of the belt guard. 3. Belts tend to stretch somewhat after installation. Recheck tension after several days of operation. Check sheave alignment as well as setscrew and/or bushing bolt tightness. COUPLING Coupling alignment should be checked after installation and prior to start up. Alignment is set at the factory, but shipping, handling, and installation can cause misalignment. Also check for proper coupling lubrication. For details on lubrication and for alignment tolerances on the particular coupling supplied, see the manufacturer s installation and maintenance supplement in the shipping envelope. Installation Most nyb fans are shipped with the coupling installed. In cases where the drive is assembled after shipping, install the coupling as follows: 1. Remove all foreign material from fan and motor shafts and coat with machine oil for easy mounting of coupling halves. 2. Mount the coupling halves on each shaft, setting the gap between the faces specified by the manufacturer. Avoid using force. If mounting difficulty is encountered, lightly polish the shaft with emery cloth until the halves slide on freely. BERG SERIES BLOWN FILM COOLER Page 26

27 Alignment 1. Align the coupling to within the manufacturer s limits for parallel and angular misalignment (see Figure 2). A dial indicator or laser can also be used for alignment where greater precision is desired. Adjustments should be made by moving the motor to change shaft angle, and by the use of foot shims to change motor shaft height. Do not move the fan shaft or bearing. 2. When correctly aligned, install the flexible element and tighten all fasteners in the coupling and motor base. Lubricate the coupling if necessary. 3. Recheck alignment and gap after a short period of operation, and recheck the tightness of all fasteners in the coupling assembly. START-UP Safe operation and maintenance includes the selection and use of appropriate safety accessories for the specific installation. This is the responsibility of the system designer and requires consideration of equipment location and accessibility as well as adjacent components. All safety accessories must be installed properly prior to start-up. Safe operating speed is a function of system temperature and wheel design. Do not under any circumstances exceed the maximum safe fan speed published in the nyb engineering supplement, which is available from your nyb field sales representative. BERG SERIES BLOWN FILM COOLER Page 27

28 Procedure 1. If the drive components are not supplied by nyb, verify with the manufacturer that the starting torque is adequate for the speed and inertia of the fan. 2. Inspect the installation prior to starting the fan. Check for any loose items or debris that could be drawn into the fan or dislodged by the fan discharge. Check the interior of the fan as well. Turn the wheel by hand to check for binding. 3. Check drive installation and belt tension. 4. Check the tightness of all setscrews, nuts and bolts. When furnished, tighten hub setscrews with the wheel oriented so that the setscrew is positioned underneath the shaft. 5. Install all remaining safety devices and guards. Verify that the supply voltage is correct and wire the motor. Bump the starter to check for proper wheel rotation. 6. Use extreme caution when testing the fan with ducting disconnected. Apply power and check for unusual sounds or excessive vibration. If either exists, see the section on Common Fan Problems. To avoid motor overload, do not run the fan for more than a few seconds if ductwork is not fully installed. On larger fans, normal operating speed may not be obtained without motor overload unless ductwork is attached. Check for correct fan speed and complete installation. Ductwork and guards must be fully installed for safety. 7. Setscrews should be rechecked after a few minutes, eight hours and two weeks of operation (see Tables 1 & 2 for correct tightening torques). NOTE: Shut the fan down immediately if there is any sudden increase in fan vibration. Table 1 WHEEL SETSCREW TORQUES Setscrew Size Diameter (in.) Carbon Steel Setscrew Torque* Lb. in. Lb. ft. ½ / ¾ * Stainless Steel setscrews are not hardened and should not be tightened to more than ½ the values shown. BERG SERIES BLOWN FILM COOLER Page 28

29 Table 2 BEARING SETSCREW TORQUE, lb. in. Setscrew Diameter Manufacturer Link-Belt Sealmaster SKF McGill Dodge ¼ / Note: Split pillow block bearings are fixed to the shaft with tapered sleeves and generally do not have setscrews. FAN MAINTENANCE nyb fans are manufactured to high standards with quality materials and components. Proper maintenance will ensure a long and trouble-free service life. Do not attempt any maintenance on a fan unless the electrical supply has been completely disconnected and locked. In many cases, a fan can windmill despite removal of all electrical power. The rotating assembly should be blocked securely before attempting maintenance of any kind. The key to good fan maintenance is regular and systematic inspection of all fan parts. Inspection frequency is determined by the severity of the application and local conditions. Strict adherence to an inspection schedule is essential. Regular fan maintenance should include the following: 1. Check the fan wheel for any wear or corrosion, as either can cause catastrophic failures. Check also for the buildup of material which can cause unbalance resulting in vibration, bearing wear and serious safety hazards. Clean or replace the wheel as required. 2. Check the V-belt drive for proper alignment and tension (see section on V-belt drives). If belts are worn, replace them as a set, matched to within manufacturer s tolerances. Lubricate the coupling of direct-drive units and check for alignment (see section on couplings). 3. Lubricate the bearings, but do not over lubricate (see the bearing section for detailed specifications). 4. Ceramic-felt shaft seals require no maintenance, although worn seals should be replaced. When lip-type shaft seals are provided, lubricate them with NEVER-SEEZ or other anti-seize compound. 5. During any routine maintenance, all setscrews and bolts should be checked for tightness. See the table for correct torques. 6. When installing a new wheel, the proper wheel-to-inlet clearance must be maintained (see Figure 3). WHEEL BALANCE Airstreams containing particulate or chemicals can cause abrasion or corrosion of the fan parts. This wear is often uneven and can lead to significant wheel unbalance over time. When such wear is discovered, a decision must be made as to whether to rebalance or replace the wheel. The soundness of all parts should be determined if the original thickness of components is reduced. Be sure there is no hidden structural damage. The airstream components should also be cleaned to remove any build-up of foreign material. Specialized equipment can be used to rebalance a cleaned wheel that is considered structurally sound. Balance weights should be rigidly attached at a point that will not interfere with the housing nor disrupt airflow. Remember that centrifugal forces can be extremely high at the outer radius of a fan wheel. Welding is the preferred method of balance weight attachment. Be sure to ground the welder directly to the fan wheel. Otherwise, the welding current could pass through the fan bearings and damage them. BERG SERIES BLOWN FILM COOLER Page 29

30 WHEEL-INLET CLEARANCE BEARINGS Storage Any stored bearing can be damaged by condensation caused by temperature variations. Therefore, nyb fan bearings are filled with grease at the factory to exclude air and moisture. Such protection is adequate for shipment and subsequent immediate installation. For long term or outdoor storage, mounted bearings should be regreased and wrapped with plastic for protection. Rotate the fan wheel by hand at least every two weeks to redistribute grease on internal bearing parts. Each month the bearings should be purged with new grease to remove condensation, since even a filled bearing can accumulate moisture. Use caution when purging, as excessive pressure can damage the seals. Rotate the shaft while slowly adding grease. Operation Check the setscrew torque before start-up (see table for correct values). Since bearings are completely filled with grease at the factory, they may run at an elevated temperature during initial operation. Surface temperatures may reach 180 F. and grease may bleed from the bearing seals. This is normal and no attempt should be made to replace lost grease. Bearing surface temperatures will decrease when the internal grease quantity reaches a normal operating level. Relubrication should follow the recommended schedule. Lubrication Use the table for relubrication scheduling according to operating speed and shaft diameter. Bearings should be lubricated with a premium quality lithium-based grease conforming to NLGI Grade 2. Examples are: Mobil - Mobilith AW2 Chevron - Amolith #2 Texaco - Premium RB Shell - Alvania #2 These greases are for bearing surface temperatures of 40 F. to 180 F, For surface temperatures of 181 F. to 230 F. use Mobilith SHC220. Do not use high temperature greases, as many are not formulated to be compatible with fan bearings. BERG SERIES BLOWN FILM COOLER Page 30

31 Add grease to the bearing while running the fan or rotating the shaft by hand. Be sure all guards are in place if lubrication is performed while the fan is operating. Add just enough grease to cause a slight purging at the seals. Except on split pillow blocks. Completely filled bearings will run hotter until a sufficient amount of grease is purged out of the seals. Split pillow block bearings (Link-Belt P-LB6800 & P-LB6900, SKF SAF 22500, Dodge SAF-XT) should be cleaned and repacked at approximately every eighth lubrication interval. This requires removal of the bearing cap. Clean out old grease and repack the bearing with fresh grease. Pack the bearing fully and fill the housing reservoir to the bottom of the shaft on both sides of the bearing. Replace the bearing cap, being careful not to mix caps as they are not interchangeable from one bearing to another. Do not over lubricate. NOTE: 1. These are general recommendations only; specific manufacturer s recommendations may vary slightly. 2. Assumes clean environment, -20 F. to 120 F. a. Consult The New York Blower Company for operation below -20 F. ambient. b. Ambient temperatures greater than 120 F. will shorten bearing life. c. Under extremely dirty conditions, lubricate more frequently. 3. Assumes horizontal mounting configuration. For vertically mounted applications, lubricate twice as frequently. BERG SERIES BLOWN FILM COOLER Page 31

32 COMMON FAN PROBLEMS Excessive Vibration A common complaint regarding industrial fans is excessive vibration. nyb is careful to ensure that each unit is precisely balanced prior to shipment; however, there are many other causes of vibration including: 4. Loose mounting bolts, setscrews, bearings or couplings. 5. Misalignment or excessive wear of couplings or bearings. 6. Misaligned or unbalanced motor. 7. Bent shaft due to mishandling or material impact. 8. Accumulation of foreign material on the wheel. 9. Excessive wear or erosion of the wheel. 10. Excessive system pressure or restriction of airflow due to closed dampers. 11. Inadequate structural support, mounting procedures or materials. 12. Externally transmitted vibration. Inadequate Performance 1. Incorrect testing procedures or calculations. 2. Fan running too slowly. 3. Fan wheel rotating in wrong direction or installed backwards on shaft. 4. Wheel not properly centered relative to inlet cone. 5. Damaged or incorrectly installed cut off sheet or diverter. 6. Poor system design, closed dampers, air leaks, clogged filters, or coils. 7. Obstructions or sharp elbows near inlets. 8. Sharp deflection of airstream at fan outlet. Excessive Noise 1. Fan operating near stall due to incorrect system design or installation. 2. Vibration originating elsewhere in the system. 3. System resonance or pulsation. 4. Improper location or orientation of fan intake and discharge. 5. Inadequate or faulty design of supporting structures. 6. Nearby sound reflecting surfaces. 7. Loose accessories or components. 8. Loose drive belts. 9. Worn bearings. Premature Component Failure 1. Prolonged or major vibration. 2. Inadequate or improper maintenance. 3. Abrasive or corrosive elements in the airstream or surrounding environment. 4. Misalignment or physical damage to rotating components or bearings. 5. Bearing failure from incorrect or contaminated lubricant or grounding through the bearings while arc welding. 6. Excessive fan speed. 7. Extreme ambient or airstream temperatures. 8. Improper belt tension. 9. Improper tightening of wheel setscrews. BERG SERIES BLOWN FILM COOLER Page 32

33 REPLACEMENT PARTS It is recommended that only factory-supplied replacement parts be used. nyb fan parts are built to be fully compatible with the original fan, using specific alloys and tolerances. These parts carry a standard nyb warranty. When ordering replacement parts, specify the part name, nyb shop and control number, fan size, type, rotation (viewed from drive end), arrangement and bearing size or bore. Most of this information is on the metal nameplate attached to the fan base. For assistance in selecting replacement parts, contact your local nyb representative or visit: Example: Part required: Wheel/shaft assembly Shop/control number: B Fan description: Size 2206A10 Pressure Blower Rotation: Clockwise Arrangement: 4 Suggested replacement parts include: Wheel Component parts: Damper Shaft Motor Bearings* Coupling* Shaft Seal* Sheaves* V-Belts* For Arrangement 1/8 fan only. BERG SERIES BLOWN FILM COOLER Page 33

34 BERG SERIES BLOWN FILM COOLER Page 34

IM-210 INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS HOODED ROOF VENTILATORS UPBLAST ROOF VENTILATORS AIR PRESSURE AND SUCTION A WORD ABOUT SAFETY

IM-210 INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS HOODED ROOF VENTILATORS UPBLAST ROOF VENTILATORS AIR PRESSURE AND SUCTION A WORD ABOUT SAFETY INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS IM-210 HOODED ROOF VENTILATORS UPBLAST ROOF VENTILATORS A WORD ABOUT SAFETY Air moving equipment involves electrical wiring, moving parts, sound, and air

More information

IM-230 AIR KITS INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS

IM-230 AIR KITS INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS IM-30 AIR KITS SOUND Some fans can generate sound that could be hazardous to exposed personnel. It is the responsibility of the system designer and user

More information

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY Jet Fans Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY All Leader Fan products are guaranteed to be free from defects of workmanship or material and to function satisfactorily when properly

More information

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting Electrical wiring and connections should be done

More information

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting Electrical wiring and connections should be

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP The purpose of this manual is to aid in the proper installation and operation of the fans.

More information

CENTRIFUGAL FANS 312 SOUTH HWY. 73, PO BOX 398 FALLS CITY, NE Revision Date 08/29/2017 1

CENTRIFUGAL FANS 312 SOUTH HWY. 73, PO BOX 398 FALLS CITY, NE Revision Date 08/29/2017 1 CENTRIFUGAL FANS Direct Drive Aeration Series C2000, C2200, C2700, C3000, C3300 High Speed Direct Drive CH-2000, CH-2200, CH-2400, CH-2700, CH-3000 Low Speed Direct Drive CL-2000, CL-2200, CL-2400, CL-2700,

More information

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST TUBE AXIAL DUCT FANS INDUSTRIAL PROPELLER FANS INDUSTRIAL ROOF EXHAUSTERS HEAVY DUTY MAN/PRODUCT COOLERS WARNING BY ACCEPTANCE OF THIS MERCHANDISE,

More information

TSL and QSL Inline Centrifugal and Mixed Flow Fans

TSL and QSL Inline Centrifugal and Mixed Flow Fans TSL and QSL Inline Centrifugal and Mixed Flow Fans INSTALLATION, OPERATION & MAINTENANCE MANUAL ES-89 September 07 Throughout this manual, there are a number of HAZARD S that must be read and adhered to

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended

More information

NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel

NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel NSGV SERIES AF PRESSURE BLOWER I, O & M MANUAL NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel RECEIVING AND INSPECTION All shipments are F.O.B. factory, Decatur, Illinois. It is, therefore,

More information

MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS

MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS READ AND SAVE THESE INSTRUCTIONS 9668-D Heinrich Hertz Drive, San Diego, CA 92154 PH: 619-946-1224 MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS SHIPPING INSPECTION Romlair Model VBO-HV & VBO fans are

More information

BCFS Belt Driven Centrifugal Filtered Supply Fans

BCFS Belt Driven Centrifugal Filtered Supply Fans BCFS Belt Driven Centrifugal Filtered Supply Fans INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-4300 August 2014 Throughout this manual, there are a number of HAZARD S that must be read and adhered to

More information

HA/HAB Fiberglass Wall Mount Ventilators

HA/HAB Fiberglass Wall Mount Ventilators HA/HAB Fiberglass Wall Mount Ventilators INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-3100 August 2015 Throughout this manual, there are a number of HAZARD S that must be read and adhered to in order

More information

Series Base mounted pump. Installation and operating instructions

Series Base mounted pump. Installation and operating instructions Series 4030 Installation and File No: 40.80 Date: june 25, 2015 Supersedes: 40.80 Date: october 10, 2009 contents General 4 Inspection 4 Installation - Series 4030 base mounted Pump 4 1.0 Location 4 2.0

More information

MODEL CLS Centrifugal Filtered Supply Fans

MODEL CLS Centrifugal Filtered Supply Fans READ AND SAVE THESE INSTRUCTIONS 9668 Heinrich Hertz Dr # D, San Diego, CA 92154 PH. 619-946-12 MODEL CLS Centrifugal Filtered Supply Fans INSTALLATION AND MAINTENANCE INSTRUCTIONS This publication contains

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN Bulletin 62-January-20-09 ROOF UPBLAST & SIDEWALL CENTRIFUGAL FIBERGLASS EXHAUST FAN INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN The M.K. Plastics catalog on the above corrosion resistant

More information

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting Electrical wiring

More information

Operation and Maintenance Manual. Series BI Centrifugal Blowers

Operation and Maintenance Manual. Series BI Centrifugal Blowers Operation and Maintenance Manual Series BI Centrifugal Blowers This publication contains the installation, operation and maintenance instructions for standard units of the Monoxivent Series BI-Centrifugal

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual PN 47 Models XUEB - Series 00 and 200 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

User s Manual D-Series Blowers and Exhausters

User s Manual D-Series Blowers and Exhausters User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1

More information

NATIONAL TURBINE CORPORATION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

NATIONAL TURBINE CORPORATION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS NATIONAL TURBINE CORPORATION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS MILLENNIUM SERIES MULTISTAGE CENTRIFUGAL BLOWERS AND EXHAUSTERS NATIONAL TURBINE CORPORATION 374 NORTHERN LIGHTS DRIVE

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Part #469003 Model Vektor -H Installation Operation and Maintenance Manual for Vektor-H Laboratory Exhaust System Receiving Greenheck model Vektor-H fans are thoroughly

More information

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual Direct Drive Sidewall Propeller Fans (Exhaust and Supply) READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is

More information

WELDING FUME EXHAUSTERS & ARMS

WELDING FUME EXHAUSTERS & ARMS WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND

More information

D-Series Blowers and Exhausters

D-Series Blowers and Exhausters Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC

More information

Installation Manual DIAPHRAGM WELL TANK

Installation Manual DIAPHRAGM WELL TANK Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH INSTALLATION INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH The purpose of this manual is to aid in the proper installation and operation of the fans. These

More information

HOOD EXHAUST OR SUPPLY PROPELLER FAN

HOOD EXHAUST OR SUPPLY PROPELLER FAN jtantay 08/10/10 HOOD EXHAUST OR SUPPLY PROPELLER FAN D x D 1 C x C 1 A x A 1 B HINGE BELT DRIVE 0.5 E SECURITY LOCK B1 SHUTTER (Optional) 1 B THROAT SIZE A x A 2 2 CUSTOM CURB (Optional) WOOD OR INSULATION

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Part #455308 Model SWB - Series 100, 200 and 300 Models SFB and SFD Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting

More information

Tubular Centrifugal Inline Fans TCN

Tubular Centrifugal Inline Fans TCN Operation and Maintenance Manual Tubular Centrifugal Inline Fans TCN MONOXIVENT - SOURCE CAPTURE SYSTEMS 0 Mill St., Rock Island, IL 0-0- - info@monoxivent.com monoxivent.com TCN Tubular Centrifugal Inline

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL CNW DHK PVK

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL CNW DHK PVK FRP Centrifugal & Inline Fans Bulletin 90-01- NOV2002 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This publication contains the installation, operation and maintenance instructions for the following

More information

IMPORTANT! READ BEFORE PROCEEDING! PHR Axial Flow Hooded Roof Ventilators

IMPORTANT! READ BEFORE PROCEEDING! PHR Axial Flow Hooded Roof Ventilators PHR Axial Flow Hooded Roof Ventilators OPERATION & MAINTENANCE Revised: 08/24/15 IMPORTANT! READ BEFORE PROCEEDING! The information contained herein is, to the best of our knowledge, accurate and applicable

More information

EZ-Stacker Air Stripper

EZ-Stacker Air Stripper EZ-Stacker Air Stripper Operation & Maintenance Manual P/N 95166 4/10/13 P.O. Box 3726 Ann Arbor, MI 48106-3726 USA 1-800-624-2026 Fax (734) 995-1170 info@qedenv.com www.qedenv.com QED Environmental Systems

More information

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material

More information

Model CWD Installation, Operation, and Maintenance Manual

Model CWD Installation, Operation, and Maintenance Manual Model CWD Installation, Operation, and Maintenance Manual Direct Drive Centrifugal Sidewall Exhausters READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and

More information

SERIES PC INSTRUCTION AND OPERATION MANUAL

SERIES PC INSTRUCTION AND OPERATION MANUAL MEGGA SERIES PC INSTRUCTION AND OPERATION MANUAL Models PCT and PCF Close-coupled and frame-mounted single-stage horizontal end-suction pumps. WARNING: Read this manual before installing or operating this

More information

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS SPUN ALUMINUM EXHAUSTER OPERATION INSTRUCTIONS AND PARTS MANUAL READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions

More information

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4- 4 (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants. DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants. FEATURES Pilot operated characterized Modulating Plug

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

Air Curtain. Installation, Operating and Maintenance Instructions

Air Curtain. Installation, Operating and Maintenance Instructions Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE

More information

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual Operating Instructions & Parts Manual EN Hazardous Location Direct-Drive Exhaust Fans Models 10D996 thru 10D999, 10E001 thru 10E007, 10E009 thru 10E020, 32ZN53 and 32ZN54 474904 PLEASE READ AND SAVE THESE

More information

INSTALLATION, OPERATION, & MAINTENANCE FOR CAR-MON EXHAUST FANS SERIES CMB, SL, & BXi

INSTALLATION, OPERATION, & MAINTENANCE FOR CAR-MON EXHAUST FANS SERIES CMB, SL, & BXi MOTOR WIRING GUIDES If the motor on your fan does not match any of the wiring diagrams supplied, you may contact the factory or the motor manufacturer directly. All of the motor companies can be reached

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Please read this manual completely before installing or operating this unit! BAGR7 Blue Air reserves

More information

Models eged/egsd. Installation, Operation, and Maintenance Manual. Direct Drive Sidewall Propeller Fans (Exhaust and Supply)

Models eged/egsd. Installation, Operation, and Maintenance Manual. Direct Drive Sidewall Propeller Fans (Exhaust and Supply) Models eged/egsd Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation of fans manufactured by JencoFan.

More information

Series Base mounted pump. Installation and operating instructions

Series Base mounted pump. Installation and operating instructions Series 4030 Installation and File No: 40.80 Date: december 12, 2016 Supersedes: 40.80 Date: july 27, 2016 contents General 4 Inspection 4 Installation - Series 4030 base mounted Pump 4 1.0 Location 4

More information

Compressor Clutch Replacement Procedure

Compressor Clutch Replacement Procedure P-1411 819-0361 Compressor Clutch Replacement Procedure Installation Instructions World Clutch with Unidamp Armature for Ford FX-15 and FS-10 Compressors and all Denso Models with 30mm bearing fit. Keep

More information

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES Document No: ICM-IOM Date: 0411 PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting

More information

Compressor Clutch Replacement Procedure

Compressor Clutch Replacement Procedure Clutch Replacement Procedure P-1401-WE 819-0316 Installation Instructions An Altra Industrial Motion Company Warner Replacement Clutches for the following compressors: Denso 6E171 10P15 6P148 6C17 Ford

More information

AC Electric Capstan Owner s Manual Installation and Operating Instructions

AC Electric Capstan Owner s Manual Installation and Operating Instructions AC Electric Capstan Owner s Manual Installation and Operating Instructions Model: HD2000-1A34-F-01 Serial Number: 123456 VAC _ Ø Hz Line Size: 1/2 CAUTION The final determination as to the suitability

More information

Spare Parts, Instruction and Maintenance Manual for SPANCO Model 301 Jib Cranes

Spare Parts, Instruction and Maintenance Manual for SPANCO Model 301 Jib Cranes Manual No. 103-0007 REV. 6/10 Spare Parts, Instruction and Maintenance Manual for SPANCO Model 301 Jib Cranes ISO 9001 REGISTERED SPANCO, Inc. 2 TABLE OF CONTENTS Forward... 4 Installation... 4-6 Maintenance...

More information

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK 2 20 BOS BUTTERFLY VALVES 2 20" BOS BUTTERFLY VALVES Instruction D10459 October 2013 2-20 BOS Butterfly Valves Instructions These instructions provide information about BOS Butterfly Valves. They are for use by personnel who are

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems Fuel Oil Transfer System THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED SYSTEM IS OF THE HIGHEST QUALITY AND DESIGN. TO OBTAIN

More information

RolsplicerTM. Maintenance Manual And Illustrated Parts List

RolsplicerTM. Maintenance Manual And Illustrated Parts List RolsplicerTM Maintenance Manual And Illustrated Parts List List of Illustrations Figure Page. Rolsplicer 3 2. Roller Adjustment 4 3. Rolsplicer 6 4. Lid Hold Down Assembly 8 5. Automatic Lid Speed Adjustment

More information

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com

More information

DELHOIST DOUBLE ACTING TELESCOPIC CYLINDERS Stoney Rise Road (P.O. Box 20), Devonport, Tasmania 7310

DELHOIST DOUBLE ACTING TELESCOPIC CYLINDERS Stoney Rise Road (P.O. Box 20), Devonport, Tasmania 7310 DELHOIST DOUBLE ACTING TELESCOPIC CYLINDERS 171-199 Stoney Rise Road (P.O. Box 20), Devonport, Tasmania 7310 Ph. (03) 6424 5711 Fax. (03) 6424 6983 E-mail sales@dh.au.com Internet: www.dh.au.com - CONTENTS

More information

TONS. Before each shift: Before operating: Before initial operation of hoist:

TONS. Before each shift: Before operating: Before initial operation of hoist: LEVER HOIST 0.25 9 TONS Manual Notice It is the responsibility of the owner/user to install, inspect, test, maintain, and operate these lever hoists in accordance with ASME B30.21, Safety Standard for

More information

MetroPrime 22MPC Self-Priming Centrifugal Pump

MetroPrime 22MPC Self-Priming Centrifugal Pump Page 1 of 6 prevent priming or reduce pump capacity. OPERATION The 22 MPC-Metropolitan Pump is a self-priming centrifugal pump and only requires priming prior to its initial start. The pump will retain

More information

SDBDe, STXDe, ered* Installation, Operation, and Maintenance Manual INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

SDBDe, STXDe, ered* Installation, Operation, and Maintenance Manual INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS SDBDe, STXDe, ered* Installation, Operation, and Maintenance Manual INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS *Model ered was discontinued on June 1, 2016 and replaced by Model

More information

Installation and Maintenance Manual for SPANCO A Series Aluminum Gantry Cranes

Installation and Maintenance Manual for SPANCO A Series Aluminum Gantry Cranes Manual No. 103-0008 REV. 6/11 Installation and Maintenance Manual for SPANCO A Series Aluminum Gantry Cranes ISO 9001 REGISTERED SPANCO, Inc. 2 TABLE OF CONTENTS Warnings... 3 Installation... 4 Maintenance...

More information

INSTALLATION AND MAINTENANCE MANUAL

INSTALLATION AND MAINTENANCE MANUAL TYPE 2 PTO INSTALLATION AND MAINTENANCE MANUAL P.O. Box 8148 Wichita Falls, Texas 76307 1600 Fisher Rd. Wichita Falls, Texas 76305 Phone: (940) 7611971 Fax: (940) 7611989 www.wptpower.com email: info@wptpower.com

More information

Skilled Air for Industry. Bran Finisher. Operators Manual

Skilled Air for Industry. Bran Finisher. Operators Manual Skilled Air for Industry Bran Finisher Operators Manual 1. Introduction When you purchased your Kice Bran & Shorts Finisher, you bought a machine that has proven its reliability based on hundreds of installations

More information

Air Actuated Hydraulic Bottle Jack on Wheels

Air Actuated Hydraulic Bottle Jack on Wheels Operating Instructions & Parts Manual Air Actuated Hydraulic Bottle Jack on Wheels Model Number 18127 18207 Capacity 12 Ton 20 Ton Shinn Fu Co. of America, Inc. 2002 10939 N. Pomona Avenue Kansas City,

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual. p.t.o. Slip clutch 65517 Installation Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com Read

More information

IMPORTANT! READ BEFORE PROCEEDING! PAF Axial Propeller Fans

IMPORTANT! READ BEFORE PROCEEDING! PAF Axial Propeller Fans PAF Axial Propeller Fans OPERATION & MAINTENANCE Revised: 08/24/15 MODELS PAFM / PAFH MODEL PAFL MODEL PAFC MODEL PAFB MODEL PAFP IMPORTANT! READ BEFORE PROCEEDING! The information contained herein is,

More information

FIGURE 310A & 311A 3-PIECE BALL VALVE

FIGURE 310A & 311A 3-PIECE BALL VALVE INTRODUCTION This instruction manual includes installation, operation and maintenance information for the figure 310A, 310ASW, 311A, and 311ASW 3-piece 1000CWP, threaded end (NPT) or socket weld end (SW)

More information

Powered Airette: Axial Flow Hooded Roof Ventilators: Direct & Belt Drive

Powered Airette: Axial Flow Hooded Roof Ventilators: Direct & Belt Drive Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

More information

Guardian Steel Gear Shaft Coupling

Guardian Steel Gear Shaft Coupling Guardian Steel Gear Shaft Coupling P-8609-GC GUA-MRK-DOC-026 Service & Installation Instructions TABLE OF CONTENTS NOTICES AND WARNINGS PAGE 2 SECTION 1 COUPLING OVERVIEW PAGE 3 SECTION 2 TOOLS/MATERIALS

More information

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How

More information

OPERATING INSTRUCTIONS ZDX 1/12CS

OPERATING INSTRUCTIONS ZDX 1/12CS OPERATING INSTRUCTIONS ZDX 1/12CS www. sethco. com info@sethco.com INDEX Warranty 2 Safety Rules 3 Operating Instructio ns 4 General Description 4 Pre-installation 4 Pump Installation 4 Piping the Pump

More information

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE INTRODUCTION This instruction manual includes installation, operation and maintenance information for the figure 310AM, 310AMSW, and 311AM 3-piece 1000CWP, threaded end (NPT) or socket weld end (SW) ball

More information

Owner s Manual GLASSLINED PUMP TANK

Owner s Manual GLASSLINED PUMP TANK Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that

More information

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com I000-7000-D0447-A 4/7/05 1 SAFETY PRECAUTIONS CAUTION Please read this entire document prior to operating the gear drive. Gear drive failure and / or injury to operators may be caused by improper installation,

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

OPERATING INSTRUCTIONS ZDX 7-1/2AS

OPERATING INSTRUCTIONS ZDX 7-1/2AS OPERATING INSTRUCTIONS ZDX 7-1/2AS www. sethco. com info@sethco.com INDEX Warranty 2 Safety Rules 3 Operating Instructio ns 4 General Description 4 Pre-installation 4 Pump Installation 4 Piping the Pump

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96

More information

Emergency Smoke Control Centrifugal Roof Exhaust Fans

Emergency Smoke Control Centrifugal Roof Exhaust Fans IN THIS SECTION Emergency Smoke Control Centrifugal Roof Exhaust Fans HA~~ISAI~ SYSTEl\t1S, INC. Heat:ing &.-Air Condit:ioning Inst:allat:ion &,-Service -------- READ AND SAVE THESE INSTRUCTIONS [RGREENHECK

More information

ROTARY BRUSH CUTTERS THE LEADER OF THE PACK OWNER/OPERATOR SAFETY & INSTRUCTION MANUAL

ROTARY BRUSH CUTTERS THE LEADER OF THE PACK OWNER/OPERATOR SAFETY & INSTRUCTION MANUAL 72 M-AX ROTARY BRUSH CUTTERS THE LEADER OF THE PACK OWNER/OPERATOR SAFETY & INSTRUCTION MANUAL CONTENTS Page 1. Introduction..................................2 2. Safety Instructions...........................3-4

More information

Positive Displacement Pump

Positive Displacement Pump www.conairgroup.com U S E R G U I D E UGC028-1105 Positive Displacement Pump Models PD 3. 5, 7.5, 10, 15 and 25 Corporate Office: 724.584.5500 l Instant Access 24/7 (Parts and Service): 800.458.1960 l

More information

Installation and Parts Manual for SPANCO E Series Gantry Cranes

Installation and Parts Manual for SPANCO E Series Gantry Cranes Manual No. 103-0004 REV. 1/10 Installation and Parts Manual for SPANCO E Series Gantry Cranes ISO 9001 REGISTERED SPANCO, Inc. TABLE OF CONTENTS Warnings... 3 Assembly Instructions... 4 Serial Number Location...

More information

SERIES G3DB/AG3DB ELEVATOR

SERIES G3DB/AG3DB ELEVATOR TM INSTRUCTIONS AND PARTS LIST SERIES G3DB/AG3DB ELEVATOR WARNING This manual, and GENERAL INSTRUCTIONS MANUAL, CA-1, should be read thoroughly prior to pump installation, operation or maintenance. SRM00059

More information

Guardian Taper Grid Shaft Coupling

Guardian Taper Grid Shaft Coupling Guardian Taper Grid Shaft Coupling P-8608-GC GUA-MRK-DOC-025 Service & Installation Instructions TABLE OF CONTENTS NOTICES AND WARNINGS PAGE 2 SECTION 1 COUPLING OVERVIEW PAGE 3 SECTION 2 TOOLS/MATERIALS

More information

Portable Electric/Gas Compressor Operating Instructions

Portable Electric/Gas Compressor Operating Instructions Portable Electric/Gas Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 TABLE OF CONTENTS Safety

More information

Rig Master Power by Mobile Thermo Systems Inc.

Rig Master Power by Mobile Thermo Systems Inc. RigMaster Power Dealer Warranty Policy The Limited Warranty This limited warranty applies to the RigMaster Auxiliary Power Unit (RigMaster APU) which consists of the following components: 1. The generator

More information

20 Gauge Super-Speed. shoprpmachine

20 Gauge Super-Speed. shoprpmachine Operator tor s s manual 20 Gauge Super-Speed 1 WARRANTY Our guarantee on the products we manufacture is limited to repair or replacement without charge, of any part found to be defective in materials or

More information

WIND STOPPING 14 (WMI) AND WIND STOPPING 16 (WMH) INDUSTRIAL SERIES

WIND STOPPING 14 (WMI) AND WIND STOPPING 16 (WMH) INDUSTRIAL SERIES Document No: W-IOM Date: 01/13/16 WIND STOPPING 14 (WMI) AND WIND STOPPING 16 (WMH) INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully

More information

Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit

Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit 10552 The following instructions are intended for professional installers. Speedtech Performance assumes NO responsibility for the installation

More information

ered Installation, Operation, and Maintenance Manual Direct Drive sizes 6-15 Nonoverloading B.I. Wheel

ered Installation, Operation, and Maintenance Manual Direct Drive sizes 6-15 Nonoverloading B.I. Wheel ered Installation, Operation, and Maintenance Manual Direct Drive sizes 6-15 Nonoverloading B.I. Wheel INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Revised November 25,2014 INTRODUCTION:

More information

WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES

WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES Document No: BD-IOM Date: 01/13/16 WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

RED23305 Owner s Manual

RED23305 Owner s Manual RED23305 Owner s Manual 5 foot, 3-Point Mounted Snow Blower 270 West Park Avenue Huron, SD 57350 866-526-5682 Serial Number: Date of Purchase: Red Devil Snow Blower See Figure 1. 1. The Red Devil Snow

More information

SQI Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SQI Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL SQI Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL This publication contains the installation, operation and maintenance instructions for standard units of the SQI: Square

More information

25 GALLON PORTABLE OIL LIFT

25 GALLON PORTABLE OIL LIFT 25 GALLON PORTABLE OIL LIFT Model 92859 SET UP AND OPERATING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L. REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion KARAM A.L. www.alternatorstarter.com 1-888-515-2726 REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL

More information

BCRFS Belt Driven Centrifugal Filtered Supply Fans

BCRFS Belt Driven Centrifugal Filtered Supply Fans BCRFS Belt Driven Centrifugal Filtered Supply Fans INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-4310 August 2014 Throughout this manual, there are a number of HAZARD S that must be read and adhered

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL VIKING HELICAL GEAR REDUCERS A, B, AND C SIZES SECTION PAGE ISSUE

More information

SDBDe, STXDe, STXDeRHUL

SDBDe, STXDe, STXDeRHUL SDBDe, STXDe, STXDeRHUL Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation of fans manufactured

More information