Installation, Operation and Maintenance Instructions

Size: px
Start display at page:

Download "Installation, Operation and Maintenance Instructions"

Transcription

1 English Installation, Operation and Maintenance Instructions TR Muncher MPA547/3

2

3 Spares & Service Contact Details Mono UK Spares +44 (0) (direct line 8.15 am 5.00 pm) Service +44 (0) (direct line 8.15 am 5.00 pm) Service +44 (0) (24 hrs) Mono Australia Telephone Facsimile Melbourne (03) (03) Sydney (02) (02) Brisbane (07) (07) Adelaide (08) (08) Perth (08) (08) Darwin (08) (08) Tasmania (03) (03) Mono New Zealand Spares & Service +64 (0) Monoflo USA Spares & Service Mono China Monoflo South America Spares & Service Telephone Facsimile Beijing +86 (0) (0) Shanghai +86 (0) (0) Spares & Service

4

5 Tools For servicing and maintenance work on the Muncher the following tools are recommended. SB Muncher; Metric Hexagon Keys - Range 6mm-8mm Metric Spanners - Range 10mm-36mm Torque Wrench Series A Muncher; Metric Hexagon Keys - Range 6mm-8mm Metric Spanners - Range 10mm-36mm Torque Wrench Series F Muncher; Metric Hexagon Keys - Range 6mm-8mm Metric Spanners - Range 10mm-36mm Torque Wrench Mono Locknut Key - Item No.s MQ F06A 9750, CF F06A 9755 and MM F06A 9760 TR Muncher; Metric Hexagon Keys - Range 6mm-14mm Metric Spanners - Range 10mm-36mm Torque Wrench Series R Muncher; Metric Hexagon Keys - Range 5mm-14mm Metric Spanners - Range 10mm-36mm Torque Wrench All equipment should be in good working condition with no signs of excessive wear. Tools

6 ATEX Warning Statements GRINDERS Due to the nature and design of grinding and macerating equipment it is possible that certain objects may enter the cutters, from the process stream, with the potential to cause sparking or jamming of the cutter assembly. All electrical equipment, including control and safety devices, should be suitably rated for the environment in to which they are installed. Where there may be a risk of an accumulation of explosive gases or dust non-sparking tools should be used for installation and maintenance. Where a grinder unit is to be installed in a potentially explosive atmosphere ensure that this has been specified at the time of purchase and that the equipment has been supplied accordingly and displays an ATEX nameplate or is supplied with a certificate of conformity. If there is any doubt as to the suitability of the equipment please contact Mono Pumps Limited before commencing with installation and commissioning. Process liquids or fluids should be kept within specified temperature limits otherwise the surface of grinder or system components may become an ignition source due to temperature rises. Where the process liquid temperature is less that 90ºC the maximum surface temperature will not exceed 90ºC provided the grinder is installed, operated and maintained in accordance with this manual. Where the process fluid temperature exceeds 90ºC the maximum surface temperature will be equal to the maximum process fluid temperature. Cavities that could allow the accumulation of explosive gases, such as under guards, should where possible, be designed out of the system. Where this is not possible they should be fully purged before any work is carried out on the grinder or system. To minimise the risk of sparking or temperature rises due to mechanical or electrical overload the following control and safety devices should be fitted. A control system that will shut the grinder down if the motor current or temperature exceed specified limits or a jam of the cutter stack occurs. This may include a system that reverses the machine in order to clear any such jam. An isolator switch that will disconnect all electrical supply to the motor and ancillary electrical equipment and be capable of being locked in the off position. All control and safety devices should be fitted, operated and maintained in accordance with the manufacturer s instructions. It is important that the grinder rotates in the correct direction to give an efficient grinding operation. This must be checked on installation and commissioning and after any maintenance has been carried out. Failure to observe this may lead to mechanical or electrical overload. When fitting drives, couplings, and guards to a grinder unit it is essential that these are correctly fitted, aligned and adjusted in accordance with the O&M instructions. Failure to do so may result in sparking due to unintended mechanical contact or temperature rises due to mechanical or electrical overload. Electrical installation and maintenance work should only be carried out by suitably qualified and competent persons and must be in accordance with relevant electrical regulations. Mechanical seals should be suitably rated for the environment. The seal and any associated equipment, such as a flushing system, must be installed, operated and maintained in accordance with the manufacturer s instructions. ATEX - Page 1 of 2 Reference - MPA547/3

7 ATEX Warning Statements Where a packed gland seal is fitted this must be correctly fitted and adjusted. This type of seal relies on the process liquid to cool the shaft and packing rings so a constant drip of liquid from the gland section is required. Where this is undesirable an alternative seal type should be fitted. Failure to operate or maintain the grinder and ancillary equipment in line with the manufacturer s instructions may lead to premature and potentially dangerous failure of components. Regular inspection, and where necessary replacement, of bearings, seals, other wearing parts and lubrication is essential. The grinder and its components have been designed to ensure safe operation within the guidelines covered by legislation. Accordingly Mono Pumps Limited have declared the machine safe to use for the duty specified as defined by the Declaration of Incorporation or Conformity that is issued with this instruction manual. The use of replacement parts that are not manufactured by or approved by Mono Pumps Limited may affect the safe operation of the grinder and it may therefore become a safety hazard to both operators and other equipment. In these circumstances the Declaration provided will become invalid. The guarantee referenced on the Terms and Conditions of Sale will also be invalidated. ATEX - Page 2 of 2 Reference - MPA547/3

8 Introduction TR Muncher This information and all the information contained herein, are the exclusive property of Mono Pumps Ltd, and contain information of a proprietary nature. It is provided for the sole purpose of transmitting the information contained to the designated recipient. This information is to be used only as specified in the instrument of transmittal. It is not to be reproduced, copied in whole, or in part, nor is information it contains to be disclosed in any manner without the written consent of Mono Pumps Ltd. Its use for any other reason than the specified shall be a violation of the agreement with the recipient concerning the legal rights of Mono Pumps Ltd. Mono Pumps Ltd reserves the right to make changes, which may obsolete certain parts of this manual. The manual gives a guide to the operation and maintenance of the TR Muncher given that all Health and Safety and good engineering practices are observed. The information below is for contract No. supplied. and gives the duty for which the equipment is Introduction

9 Index SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION 9 SECTION 10 INSTALLATION START-UP PROCEDURE DISMANTLING AND ASSEMBLY ADVICE WIRING DIAGRAM DRAWING REF. No.'s / TORQUE DATA ASSEMBLY / RE-ASSEMBLY ADVICE AND STACKING ARRANGEMENT DISMANTLING AND ASSEMBLY DIAGRAMS EXPLODED VIEWS SECTIONAL ARRANGEMENTS GENERAL ARRANGEMENTS LIFTING AND GUARDING DIAGRAMS MONO PRODUCTS EC Declaration as defined by Machinery Directive 98/37/EC. EC Declaration of Incorporation This declaration is only valid when the machinery has been supplied without drive unit. In this case, the machinery meets the requirements of the said directive and is intended for incorporation into other machinery or for assembly with other machinery in order to constitute relevant machinery as defined by the said directive including any amendments, which are valid at the time of supply. IMPORTANT This machinery must not be put into service until the relevant machinery into which it is to be incorporated has been declared in conformity to the said directive. This declaration is only valid when the machinery has been installed, operated and maintained in accordance with these instructions and safety guidelines contained within as well as instructions supplied for equipment assembled with or intended for use with this equipment. The following harmonised standards are applicable: BS EN 809 BS EN ISO Parts 1 & 2 EC Declaration of Conformity This declaration is only valid when the machinery has been supplied with drive unit. In this case the machinery meets the requirements of the said directive including any amendments which are valid at the time of supply. IMPORTANT This declaration is only valid when the machinery has been installed, operated and maintained in accordance with these instructions and safety guidelines contained within as well as instructions supplied for equipment assembled with or intended for use with this equipment. Mr G.D. Thomas, Chief Engineer Index

10 Installation, Operation & Maintenance Instructions 1.0 INSTALLATION 1.1 INSTALLATION & SAFETY RECOMMENDATIONS In common with other items of process plant a Muncher must be installed correctly to ensure satisfactory and safe operation. The Muncher must also be maintained to a suitable standard. Following these recommendations will ensure that the safety of personnel and satisfactory operation of the Muncher is achieved OPERATING PRINCIPLE The Muncher The Muncher is a slow speed, high torque grinder designed to operate in the water, waste and biowaste industries. All Munchers have two shafts operating at differential speeds. Each shaft is fitted with identical interleaving cutters and spacers. 1.2 GENERAL When handling harmful or objectionable materials, adequate ventilation must be provided in order to disperse dangerous concentrations of vapours. It is recommended that wherever possible, Mono Munchers should be installed with provision for adequate lighting, thus ensuring that effective maintenance can be carried out in satisfactory conditions. With certain product materials, a hosing down facility with adequate draining will simplify maintenance and prolong the life of the Muncher components. 1.3 SYSTEM DESIGN AND INSTALLATION At the system design stage, consideration must be given to the provision of filler plugs, and the installation of non-return and/or isolating valves where applicable. Series 'F' AND 'H' Munchers are horizontal dry waste machines and must be fixed rigidly and horizontally either to the ground, or to a rigid system. TR Pipeline models are designed for horizontal installation only. Series 'A', SB and R open channel models do not require fixing to the ground and can be supported either by the concrete channel or by steel supports bolted to the concrete channel walls. Pipework to and from the unit should be independently supported and not rely on the Muncher as a means of support. Wherever possible when installed in a vertical pipe system the Muncher unit should be independently supported. 1.4 HANDLING Lift Correctly During installation and maintenance, attention must be paid to the safe handling of all items. Where a Muncher or its components weigh in excess of 20kg (45Ib) it is recommended that suitable lifting tackle should be used to ensure that personal injury or damage to components does not occur. A weight table is included at the end of this section. Lifting illustrations are contained in this document -Section 8. NOTE DO NOT ATTEMPT TO LIFT MUNCHER USING ONLY ONE LIFTING LUG. EXTREME CAUTION SHOULD BE OBSERVED FOR PERSONNEL SAFETY WHEN LIFTING HEAVY OBJECTS. 1.5 STORAGE Munchers are despatched from our factory with the cutter chamber sprayed with a moisture repellent coating and ready for immediate installation and operation. Should the machine be stored or left stationary for any length of time it is recommended that the cutter bank is re-sprayed with anti-rust lubricant and that the shafts are rotated monthly. Removing the motor cowl and turning the fan by hand is the easiest way to rotate the shafts. Failure to do this may result in a higher frequency of reversals and in extreme cases the machine to seize due to the tight running clearances of the individual cutting elements during commissioning and initial start-up. The starter panel if supplied should be stored in a controlled dry environment to prevent moisture build-up causing corrosion of contactors and other metallic components. Series 'A', SB and R pipeline models can be installed at any attitude. Section 1, Page 1

11 Installation, Operation & Maintenance Instructions See manufacturer instructions for motor/gearbox/drive and panel storage procedures. NOTE: The Muncher must be protected by a PLC control unit set up to the correct operating philosophy. Only PLC s supplied or approved by Mono Pumps Limited should be used. Failure to observe this requirement may cause premature machine failure and could invalidate the warranty of the machine. It is also important that the PLC be correctly wired into the panel. Please refer to Wiring Diagram Section 4, Page 1. IMMEDIATELY PRIOR TO INSTALLATION AND STARTING Before installing the Muncher please ensure that all plugs and inspection plates are replaced. 1.6 ELECTRICAL Electrical connection should only be made using equipment suitable for both rating and environment. Where any doubts exist regarding the suitability of equipment. Mono Pumps Limited should be consulted before proceeding. Earthing points will be provided on electric drives (if supplied) and it is essential that these are correctly connected. The electrical installation should include appropriate isolating equipment to ensure that the unit is safe to work on. 1.7 GENERAL SAFETY Guards must be used GREAT CARE MUST BE TAKEN TO PROTECT ALL ELECTRICAL EQUIPMENT FROM SPLASHING WHEN HOSING DOWN. WHERE MONO PUMPS LIMITED HAVE SUPPLIED A BASIC MUNCHER THE ONUS IS ON THE USER TO FIT ADEQUATE GUARDS IN COMPLIANCE WITH THE REQUIREMENTS OF THE RELEVANT REGULATIONS. All nuts and bolts, securing flanges and base mounting fixtures must be checked for tightness before operation. When commissioning the plant, all joints in the system must be checked thoroughly for leakage. GUARDS Guards must be used NOTE: NEVER inspect or work on or near the cutter chamber without first isolating and locking the machine. In the interests of safety, and in accordance with relevant legislation, all guards must be replaced after necessary adjustments have been made. It is strongly recommended that a Series 'F' or 'H' horizontal dry Muncher system should incorporate: - a) A steel (or similar) feed hopper with a minimum base to top height of 1.0 metre or a minimum height of 1.5 metres from floor level. b) A steel (or similar) lower delivery chute, which is inaccessible without tools. c) A protective grid mounted over the Muncher and conveyor system, especially where overhead walkways are present. d) Emergency stop buttons positioned within easy reach of all operating staff. The recommended extent of enclosure is illustrated in this document - Section WARNING /CONTROL DEVICE Prior to operating the Muncher, if any warning or control devices are fitted these must be set in accordance with their specific instructions NOISE LEVELS The noise sound pressure level will not exceed 70dB at one metre distance from the Muncher. This is based on a typical installation and does not necessarily include noise from other sources or any contribution from building reverberation. 1.8 EXPLOSIVE PRODUCTS/ HAZARDOUS ATMOSPHERES In certain instances the product being treated may well be of a hazardous nature. In these installations consideration must be given to provide suitable protection and appropriate warnings to safeguard personnel and plant. If, when starting, the Muncher does not appear to operate correctly, the plant must be shut down immediately and the cause of the malfunction established before operations are recommenced. Section 1, Page 2

12 Installation, Operation & Maintenance Instructions 1.9 LUBRICATION The gearmotor(s) is supplied with the correct type and quantity of lubricant in the gearbox but should be checked before use. For further data see separate information supplied by manufacturer. Series 'F' and 'H' bearings and rotary shaft seals are lubricated via greasing points on each bearing housing. The correct quantity of grease is reached when excess can be seen around the outer lipseal. Other models have sealed for life bearings that do not require maintenance. Gears should be inspected periodically to see if grease replenishment is necessary, and if so, grease should be added via the grease nipple until the housing is two thirds full. Only use recommended lubricant shown below for Muncher shaft gears, bearings and rotary seals. BP Energrease LC2 (-30 C to 180 C). At the following intervals, bearings, gears and seal assembly inspection should take place along with lubricant replenishment; Series 'F', 'H', R - 7,500 hrs Series 'A', SB, TR - 10,000 hrs PIPELINE MUNCHERS SHOULD BE ISOLATED BY CLOSING LINE VALVES PRIOR TO SERVICING. Under tropical or other arduous conditions, however, more frequent lubrication may be necessary. It is therefore advisable to establish a suitable maintenance schedule or periodic inspection to match service conditions. Section 1, Page 3

13 Weights Muncher Type Gear Unit / Class M/C Size (kw) Weight (kg) Series A Series F Series H SB TR R CA202AA 241 CA203AA 251 CA205AA 276 IP CA206AA 286 CA210AA 351 CA215AA 400 CA202AB 254 CA203AB 264 CA205AB 284 IP CA206AB 294 CA210AB 369 CA215AB 439 CA202AC 265 CA203AC 275 CA205AC 295 IP CA206AC 305 CA210AC 380 CA215AC 450 CF306RJS7B Nord IP55 CF310RMS7B2 7.5 & CH CH09 Nord IP55 11 & 15 /15 & CH Pipeline CB201 Channel CB201A CT203C CT203D CT203E CT205F CT205G IP55 IP55 IP55 IP67 & 68 IP55 IP55 IP55 IP55 IP / / / / / CR145A IP Section 1, Page 4

14 Installation, Operation & Maintenance Instructions 2.0 START-UP PROCEDURE W By the nature of the equipment and its operating environment the Muncher can be an extremely dangerous machine. It is vital that operators are conversant with these Operation and Maintenance Instructions prior to working with the machine. here applicable: 1) Check the foundation bolts are secure once the machine is installed in its correct operating position. 10) Start the feed system to the machine. Care should be taken not to overburden the machine. Adjust feed to maintain only the smallest practical reservoir of material in cutter banks. 11) After a further 10 minutes of running, stop the machine, switch off and lock the main isolator. Check the tightness of all securing bolts. Recheck every 500 hours of operating time. 12) Check the tightness of all cables and connections. Re-check every 500 hours of operating time. Guards must be used 2) Check the gearbox lubricant, remove the plug and fit the air vent to prevent gearbox pressurisation. Not applicable to submersible drive units. 3) Check all electrical connections for continuity and earthing and that installation is in accordance with relevant regulations and circuit diagrams. 4) If a feed hopper is fitted, check that it is secure and installed correctly, and that no personnel can gain access to the moving parts of the machine. 5) Always ensure that machine is guarded in accordance with PD5304: 2000 Safety of Machinery requirements before any attempt is made to operate. 6) On start-up check the direction of rotation of the cutters. The cutters should rotate towards the centre when viewed from the inlet side. 13) Observe manufacturers guidelines with regard to gearbox lubricant initial renewal and subsequent intervals. 14) In the event of machine overload (jam), the controller is programmed to activate the following procedure:- i) Momentarily reverse rotation to clear the condition, then return to normal operation. ii) If overload re-occurs within 60 seconds, reverse rotation to clear the condition, then return to normal operation. iii) If a third overload occurs within 60 seconds of the first, machine shutdown in reverse mode and energise alarm circuit. 15) After machine shutdown, isolate and lock off. Inspect machine, removing any obstruction and press the "RESET" button. 16) The machine can now be re-started as 9) above. NOTE: If it is necessary to remove any inspection cover to observe the action EXTREME CARE should be observed when carrying out this procedure. 7) Check that the Muncher stops when "STOP" button(s) are activated. NOTE: NEVER inspect or work on or near the cutter chamber without first isolating and locking the machine. 8) Check for reverse rotation of cutters when "REVERSE" button is activated. 9) Start up the machine. On initial start-up, allow machine to run for approximately 45 minutes. Section 2, Page 1

15 Installation, Operation & Maintenance Instructions 3.0 DISMANTLING AND ASSEMBLY Section 3 contains the steps to dismantle and reassemble the Muncher. All fastenings must be tightened securely and where identified the appropriate torque figures should be used. 3.1 USE OF ITEMS NOT APPROVED OR MANUFACTURED BY MONO PUMPS LIMITED The Muncher and its components have been designed to ensure that the machine will operate safely within the guidelines covered by the legislation. As a consequence Mono Pumps Limited have declared the machine safe to use for the duty specified as defined by the Declaration of Incorporation or Conformity that is issued with this Instruction Manual. The use of replacement items that are not approved by or manufactured by Mono Pumps Limited may affect the safe operation of the machine and it may therefore become a safety hazard to both operators and other equipment. In these instances the Declaration provided will therefore become invalid. The guarantee referenced in the Terms and Conditions of Sale will also be invalidated if replacement items are used that are not approved or manufactured by Mono Pumps Limited. 3.2 DISMANTLING ADVICE (Refer to specified drawings). 3.3 CLEANING / INSPECTION 1) Steam clean and disinfect all parts of the Muncher excluding motor, seal assemblies, gear drive unit and bearings. 2) Remove any gasket material from joint faces. 3) Housings should be cleaned thoroughly. 4) Inspect all parts for excessive wear and replace if necessary. 5) Sealed bearings cannot be re-greased, replace if necessary. 6) Check and if necessary replace the internal 'O'- rings, lipseals and mechanical seals. 7) Inspect gears for wear and damage and replace if necessary. 8) All cutters and spacers must be clean and free from cracks or excessive wear. 9) Shafts should be clean and any burrs filed off for easier stacking. Inspect shafts for excessive wear of hexagonal portion. Replace if necessary. 3.4 REASSEMBLY ADVICE 1) Lubricate all bores, shafts and seals on reassembly. 2) Lubricate gears on re-assembly with the specified lubricant. 3) Reconnect wiring at motor(s) terminal box(es) using tag leads for identification. 4) Re-open system isolation valves. 5) On completion of assembly, run through the 'initial start-up' procedure in section 2. CAUTION: When servicing the Muncher, be certain that the mains isolator is off and padlocked. Serious injury could result from accidental start-up. 1) Disconnect wiring at motor(s) terminal box(es) and tag leads for identification. 2) Pipeline models - Isolate the Muncher pipeline by closing line valves before and after the machine. 3) If necessary, the Muncher may be completely removed from installation using the recommended lifting equipment. 4) Pipeline models - Replace the pull back assembly with the maintenance period screen (MPS) if required. 5) When dismantling cutters and spacers, take careful note of the position and orientation of each component. Section 3, Page 1

16 Wiring Diagram Note: Other language versions may be available on request. Please contact Mono Pumps. Section 4, Page 1

17 Drawing Reference Numbers DRG.REF P101 P102 P103 P104 P105 P106 P107 DESCRIPTION BEARING HOUSING DATUM TUBE MAIN BODY MUNCHER NAMEPLATE TOP COVER PLATE SEAL RETAINING PLATE MAIN BODY GASKET INSPECTION COVER GASKET CUTTER DRIVE SHAFT DRIVEN SHAFT SPACER SHAFT ENDCAP SEAL RETAINING WASHER INSPECTION COVER DRIVE GEAR DRIVEN GEAR M8x55 HEX SOCKET CAP SCREW M8 SPRING WASHER M8x30 HEX SOCKET CAP SCREW M8 SPRING WASHER M12x50 HEX SOCKET CAP SCREW M12 SPRING WASHER INTERNAL CIRCLIP-90mm DRG.REF. P108 P109 P110 P111 P112 P113 P114 P115 P116 P117 P118 P119 P120 P121 P122 P123 P124 P400 P401 P402 P500 P501 P502 P503 DESCRIPTION EXTERNAL CIRCLIP-55mm RECT PAR KEY - 16x10x47 LIPSEAL - 50x65x8 10x25 DOWEL 8x25 DOWEL BEARING - 50x90x20 MECH SEAL -60mm M16x45 HEX SOCKET CAP SCREW M16 SPRING WASHER M16x45 HEX SOCKET CAP SCREW - L.H. M16 SPRING WASHER M12x25 HEX HEAD SCREW M12 SPRING WASHER WARNING LABEL No. 0 x 3/16" HD DRIVE SCREW No. 0 x 3/16" HD DRIVE SCREW 1/8" GREASE NIPPLE SEAL PLATE BOLT SEAL PLATE WASHER SEAL PLATE SPRING WASHER RECT PAR KEY - 14x9x105 M12 x 30 HEX HEAD SCREW M12 SPRING WASHER M20 EYEBOLT IMPORTANT NOTE: - THE DRAWING REFERENCES SHOWN GIVE THE DESCRIPTION OF ALL THE PARTS DETAILED ON THE SECTIONAL DRAWINGS IN THIS SECTION OF THE BOOK. THEREFORE SOME OF THE REFERENCES MAY NOT BE SHOWN ON ANY ONE. Torque Tightening Table for Fasteners DESCRIPTION THREAD SIZE PART No.(s) TOP COVER PLATE BOLT TOP COVER PLATE BOLT BEARING HOUSING BOLT DRIVESHAFT BOLT DRIVEN SHAFT BOLT SEAL PLATE BOLT INSPECTION COVER BOLT MOTOR MOUNT BOLT M8x1.25 M8x1.25 M12x1.75 M16x2 M16x2 (L.H.) M12x1.75 M16x2 M12x1.75 P101 P103 P105 P115 P117 P119 P400 P501 MAX. TIGHTENING TORQUE Nm lbf.ft Torque tolerances are +/- 5% of stated values. Assembly/Re-Assembly Advice 1. Use anti-seize compound on shafts. 2. Ensure correct orientation of bearing housing drain holes. 3. When viewed from drain holes side, driveshaft is to the right. 4. Where necessary use jacking screw holes to remove difficult components. 5. Observe the cutter stacking table guidelines below. CUTTER STACKING TABLE MODEL / DRIVE SHAFT DRIVEN SHAFT TOOTH WIDTH CUTTERS SPACERS START TOP FINISH BOTTOM CUTTERS SPACERS START TOP FINISH BOTTOM CT203-W A CUTTER CUTTER SPACER SPACER CT203-W B SPACER CUTTER CUTTER SPACER CT205-W A CUTTER CUTTER SPACER SPACER CT205-W B SPACER CUTTER CUTTER SPACER Section 4, Page 2

18 Stacking Arrangement T (x21) T (x22) T000 25*0 (x22) T000 35*0 (x21) T000 25*0 (x20) T000 35*0 (x23) T (x2) T mm Throat, 5.5mm Cutters T (x2) with Bottom Support T T Bearing T (x20) T (x23) 300mm Throat, 5.5mm Cutters Section 4, Page 4

19 Stacking Arrangement 300mm Throat, 8mm Cutters T mm Throat, 8mm Cutters with Bottom Support Bearing T000 25*1 (x15) T000 35*1 (x15) T000 25*1 (x15) T000 35*1 (x15) T000 25*1 (x14) T000 35*0 (x16) T (x2) T T000 25*1 (x14) T000 35*0 (x16) T (x2) T Section 4, Page 5

20 Stacking Arrangement 500mm Throat, 5.5mm Cutters T T (x35) T (x36) T (x36) T (x35) T (x2) Section 4, Page 6

21 Stacking Arrangement 500mm Throat, 5.5mm Cutters with Bottom Support Bearing T T (x34) T (x37) T (x34) T (x37) T (x2) T Section 4, Page 7

22 Stacking Arrangement T (x2) T T T (x25) T (x25) T (x25) T (x25) T (x24) T (x26) T (x24) T (x26) 500mm Throat, 8mm Cutters 500mm Throat, 8mm Cutters T (x2) with Bottom Support T Bearing Section 4, Page 8

23 Dismantling & Assembly Diagrams Section 5, Page 1

24 Dismantling & Assembly Diagrams Section 5, Page 2

25 Dismantling & Assembly Diagrams Section 5, Page 3

26 Dismantling & Assembly Diagrams Section 5, Page 4

27 Dismantling & Assembly Diagrams Section 5, Page 5

28 Dismantling & Assembly Diagrams Section 5, Page 6

29 Dismantling & Assembly Diagrams Section 5, Page 7

30 Dismantling & Assembly Diagrams Section 5, Page 8

31 Dismantling & Assembly Diagrams Section 5, Page 9

32 Dismantling & Assembly Diagrams Section 5, Page 10

33 Dismantling & Assembly Diagrams Section 5, Page 11

34 Dismantling & Assembly Diagrams ROTATION Section 5, Page 12

35 Exploded Views P501 P502 P110 P103 P104 P101 P P113 P107 P P120 P P114 P124 P105 P106 P P503 P500 P109 P400 P401 P P P400 P401 P402 Section 6, Page 1

36 Exploded Views P109 P500 P P118 P116 P117 P115 Section 6, Page 2

37 Sectional Arrangement C C 1100 P103* P104 B P500 P503 P111 P101* P102 P113 P124 P P114 P400* P P C-C - SECTION THROUGH DRIVESHAFT B P400* P401 P402 INSPECTION COVER DETAILS P110 P107 P112 P P119* P P117* P118 P115* 3650 P116 B-B - ALIGNED SECTION THROUGH SHAFTS Drawing Number T Section 7, Page 1

38 K General Arrangement 542 I E A C 'L' HOLES Ø'M' ON A 'N' PCD O 4-HOLES Ø18 D J G H B F DIMS. IN mm MODEL No. kw A B C D E F G H I J K L M N O Wt. Kg CT203C CT203D CT203E CT205F CT205G CT203C CT203D CT203E CT205F CT205G FLANGES DRILLED TO BS 4504 PN16 Section 8, Page 1 Drawing Number T

39 Lifting & Guarding Diagrams Section 9, Page 1

40 Mono Products Progressing Cavity (P.C.) Pumps E Range Up to 420m³/h, 72 bar Merlin Ind. Range Up to 60m³/h, 10 bar LF Range Up to 600l/h, 12 bar Monobloc Compact Range Up to 225m³/h, 24 bar W Range Up to 215m³/h, 48 bar S Range Up to 60m³/h, 12 bar B/G/M Range Up to 3m³/h, 5 bar Solar Pumps Up to 5.8m³/h, 12 bar Section 6, Page 1

41 Mono Products Grinder / Screens / Extractor Packages Mutrator Up to 15m³/h Discreen Up to 13,400m³/h Compact Munchpump Up to 25m³/h Screw Extraction Package Up to 13,900m³/h Macerator Up to 15m³/h Grifter Up to 4m³/h Muncher Family Up to 650m³/h Section 10, Page 2

42

43 Europe Mono Pumps Ltd, Martin Street, Audenshaw Manchester, M34 5JA, England T E. D.M.I EST, 56, rue du Pont Rebeuville, France T E. dmi-est@dmi-est.fr Americas Monoflo Inc., Fisher Road Houston, Texas 77041, USA T E. inquire@monoflo.com Monoflo S.A., Ing Huergo 2239 (1842) Monte Grande Pcia. de Buenos Aires, Argentina T /50 E. info@monoflo.com.ar Monoflo Canada, rd Ave Alberta, Lloydminster T9V2T2, Canada T: E: info@monoflo.com.ar Asia Mono Pumps Ltd, No. 500 YaGang Road Lujia Village, Malu, Jiading District Shanghai , P.R. China T E. monoshanghai@nov.com Australasia Mono Pumps (Australia) Pty Ltd Lower Dandenong Road Mordialloc, Victoria 3195, Australia T E. ozsales@mono-pumps.com Mono Pumps (New Zealand) Ltd Fremlin Place, Avondale Auckland, 1026, New Zealand T E. info@mono-pumps.co.nz Melbourne T F Sydney T F Brisbane T F Adelaide T F Perth T F Darwin T F Kalgoorlie T F Christchurch NZ T F Mono Pumps Limited December 2009 Literature reference: MPA547/3 Mono is a registered trademark of Mono Pumps Limited. seepex is a registered trademark of seepex Seeberger GmbH + Co. NEMO, NM and NE are registered trademarks of Erich Netzsch GmbH & Co Holding KG. NETZSCH is a registered trademark of NETZSCH Mohnopumpen GmbH. Mono Pumps Limited is not an authorised distributor of parts and services for the products of Seeberger GmbH, Allweiler, NETZSCH Mohnopumpen GmbH, PCM, Robbins & Myers or Orbit and Mono Pumps Limited products are not associated with, endorsed by, or sponsored or manufactured by these companies. Produced on recycled paper

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions TR Muncher WD127/18 Rev 14, April 2013 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct line

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and Maintenance Instructions Solar Pressure Systems MPA581/5 Contents Warranty 3 Warranty Statement 3 Introduction 4 System Overview 4 Intended Use 4 Warnings 4 Selection

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and Maintenance Instructions Macerator MPA518/2 ATEX Warning Statements GRINDERS Due to the nature and design of grinding and macerating equipment it is possible that certain

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions Series A Muncher WD001 Rev 6, October 2009 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and Maintenance Instructions Series A Muncher WD001/0 Rev 6, October 009 Spares & Service Contact Details Mono UK Spares +44 (0)161 14 80 (direct line 8.15 am 5.00 pm) E-mail

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions Macerator WD064/8 Rev 5, December 2009 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct line

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and Maintenance Instructions Mono PowerPak Generator Interface for Mono Solar Water Pumping Systems MPA591/5 Contents Warranty 5 Introduction 6 Features 6 Product Coding

More information

Innovative suction chamber design

Innovative suction chamber design EZstrip Range Innovative suction chamber design What can you do in 21/2 minutes? Mono first began manufacturing progressing cavity pumps in 1935 and have continued to engineer industry-leading pump ranges

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and Maintenance Instructions LF Range MPA536/3 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct line 8.15 am 5.00 pm) E-mail spares@mono-pumps.com

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and Maintenance Instructions ASP Surface Pump MPA551/4 Contents Warranty Statement 4 Features 5 Introduction 5 System Overview 5 Warnings 5 Intended use 5 Specifications

More information

Waste Water Solutions

Waste Water Solutions Waste Water Solutions Mono is a leading name in the design, manufacture and supply of progressing cavity pumps, parts, grinders, screens and packaged solutions, worldwide. We have 7 international sites

More information

1127_MuncherAm:28146_MuncherUK16ppR10 15/4/08 14:17 Page 1 Muncher Family

1127_MuncherAm:28146_MuncherUK16ppR10 15/4/08 14:17 Page 1 Muncher Family Muncher Family Introduction Time and time again The Muncher Family proves to be the most economical solution to a problem many of our customers previously thought impossible to solve. protection of submersible

More information

Features & Benefits. A competitively priced progressing cavity pump, with a compact construction and maximum performance characteristics.

Features & Benefits. A competitively priced progressing cavity pump, with a compact construction and maximum performance characteristics. Compact C Range Sludge pumping Features & Benefits Capacity up to 225m 3 /h Pressure up to 24 bar Temperature -10 C up to 100 C Typical applications include: Domestic and industrial effluents Hydrated

More information

Widethroat W Range W ᓔষ

Widethroat W Range W ᓔষ Widethroat W Range W The Widethroat W Range W The Mono Pedigree Mono have been at the forefront of progressing cavity pump design since 1935. With the experience gained from over 70 years we are able to

More information

Cake Pump Maintenance Made Easy!

Cake Pump Maintenance Made Easy! EZstrip Cake Pump Innovative feed chamber design Cake Pump Maintenance Made Easy! Following the successful launch of the revolutionary EZstrip progressing cavity pump, NOV Mono has developed another innovation

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions MS Range OMMP/013/01 Rev 5, December 2009 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and MPA586/2 Index PAGE: 1 SECTION 1: BLACKMONT MUNCHER CONTROL BOX PAGE 1.1 Introduction 2 1.2 Operation 2 1.3 Standard Features 3 1.4 Options 3 1.5 Muncher Control Part

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and Maintenance Instructions ASP Surface Pump MPA551/5 Contents Warranty Statement 4 Features 5 Introduction 5 System Overview 5 Warnings 5 Intended use 5 Specifications

More information

Product Dimensions MODEL MODEL

Product Dimensions MODEL MODEL Helios Range Wine pumping Features & Benefits Capacity up to 180m 3 /h Pressure up to 24 bar Temperature -10 C up to 100 C esigned specifically for hygienic applications, including shear sensitive or delicate

More information

Waste Water Solutions

Waste Water Solutions Waste Water Solutions Mono is a leading name in the design, manufacture and supply of progressing cavity pumps, parts, grinders, screens and packaged solutions, worldwide. We have 7 international sites

More information

Artificial Lift. Production Automation

Artificial Lift. Production Automation Artificial Lift Production Automation NOV Monoflo is a leading name in the design, manufacture and supply of progressing cavity pumps, grinders, screens and packaged solutions worldwide. We have 8 international

More information

Waste Water Solutions

Waste Water Solutions Waste Water Solutions Mono is a leading name in the design, manufacture and supply of progressing cavity pumps, parts, grinders, screens and packaged solutions, worldwide. We have 7 international sites

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions G Range OMMP/012/01 Rev 6, December 2009 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct line

More information

9085_MonoPUmpsLFRangeA4_8pp 18/1/13 14:24 Page 1 LF Range

9085_MonoPUmpsLFRangeA4_8pp 18/1/13 14:24 Page 1 LF Range LF Range Low Flow Pumps for Dosing Accuracy, Reliability, Simplicity The Mono Pedigree Mono have been at the forefront of progressing cavity pump design since 1935. With the experience gained from over

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions Epsilon Range Size E1XB and below OMMP/034/01 Rev 8, December 2009 Spares & Service Contact Details Mono UK Spares +44

More information

EZstrip Transfer Pump

EZstrip Transfer Pump EZstrip Transfer Pump Pump Challenge Traditional progressing cavity (PC) pump maintenance requires full removal from the pipe work to replace the pump s rotor, stator, and connecting rod assembly. This

More information

11265_MONO_UK_Muncher_16pp 21/03/2014 2:56 pm Page 1 MuncherTM Family

11265_MONO_UK_Muncher_16pp 21/03/2014 2:56 pm Page 1 MuncherTM Family Muncher Family TM Introduction Time and time again The Muncher Family proves to be the most economical solution to a problem many of our customers previously thought impossible to solve. protection of

More information

Agricultural Water Pumping Systems

Agricultural Water Pumping Systems Agricultural Water Pumping Systems CP Pump Features & Benefits Ideal for drawing water from wells, dams, creeks or shallow bores The materials of construction provide a high resistance to alkalis, organic

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions MS Range OMMP/013/01 Rev 9, April 2015 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct line

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions W Range OMMP/008/01 Rev 5, December 2009 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct line

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions Epsilon Range E14A - E1BK single stage, two stage & K build OMMP/034/03 Rev 8, December 2009 Spares & Service Contact

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Installation, Operation and Maintenance Instructions Sun-Ray SRX Solar Water Pumping Systems MPA582/2 Contents Warranty 4 Warranty Statement 4 Introduction 5 Intended Use 5 System Overview 5 Warnings

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions Compact EZ Strip Range OMMP/042/01 Rev 12, April 2013 Spares & Service Contact Details Mono UK Spares E-mail Service E-mail

More information

Installation, Operating and Maintenance Instructions

Installation, Operating and Maintenance Instructions 310190012001 EN 03.2017 1411-00 Installation, Operating and Maintenance Instructions www.sulzer.com 4 Installation, Operating and Maintenance Instructions (Original Instructions) Table of contents 1

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions Compact Range OMMP/032/01 Rev 11, December 2009 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380 (direct

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions Large 2-3 Geometry Compact Pumps (APP Project) MPA622 Spares & Service Contact Details Mono UK Spares +44 (0)161 214 2380

More information

Installation Instructions. Install Hubs Set Spacing Install Element FINISHED BORE INTERFERENCE FIT. Step 1 - HUB INSTALLATION

Installation Instructions. Install Hubs Set Spacing Install Element FINISHED BORE INTERFERENCE FIT. Step 1 - HUB INSTALLATION Instruction Manual for Baldor Dodge Raptor Spacer Couplings These instructions must be read thoroughly before installing or operating this product. Video walkthroughs of each installation procedure are

More information

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions English Original Instructions Installation, Operation and Maintenance Instructions EZstrip Cake Pump - Mono OMMP/044/01 Spares & Service Contact Details UK Spares E-mail Service E-mail Service +44 (0)161

More information

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23

Operating Instructions: Hand-operated, PTFE-lined butterfly valves, Series 22/23 0 Introduction These instructions are intended to assist users of BRAY PTFE-lined butterfly valves, Series 22/23 in fitting, operating and servicing valves. Risks may arise and the manufacturer's warranty

More information

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions 3579049/14 IM-P357-29 CTLS Issue 14 PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions PN9100 PN9200 1. Safety information 2. General product information PN9300 3. Installation

More information

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour 1.0 Introduction The Nuaire Axus range of Long Cased Axial Flow Fans are produced in sixteen case sizes from 315mm dia. to 1600mm dia. with duties up to 65m3/s. Impellers are manufactured in aluminium

More information

M Series Condensate Recovery Unit

M Series Condensate Recovery Unit 0898050/3 IM-P089-29 ST Issue 3 M Series Condensate Recovery Unit Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Wiring diagram

More information

Operation Manual Cobra 1 Automatic Spray Gun

Operation Manual Cobra 1 Automatic Spray Gun SB-E-2-CBA1 ISS.06 Operation Manual Cobra 1 Automatic Spray Gun E P 1 12 1 Operation Manual Cobra 1 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this

More information

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun EN SB-E-2-CBA1 ISS.13 Operation Manual Cobra 1 Automatic Spray Gun Operation Manual Cobra 1 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this equipment

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05 Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E-2-790 ISS.05 Operation Manual FLG5 Gravity-feed Spray Gun Important Read and follow all instructions and Safety Precautions before using this equipment

More information

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01 PrintPRO Universal Contents Overview 1 01 02 03 Overview of your extraction system (front) Overview of your extraction system (back) Overview of the Control Panel Safety Instructions 2 01 Important safety

More information

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Installation Instructions

Installation Instructions Installation Instructions Durametallic Double CRO Dual single coil spring friction drive for applications with water lubrication properties 1 Equipment Check 1.1 Follow plant safety regulations prior to

More information

BLACKMER BYPASS VALVES

BLACKMER BYPASS VALVES BLACKMER BYPASS VALVES INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EBSRAY MODEL: RV18 RV18CBS2, RV18CBS3, RV18VRS10, RV18VRS14, RV18VRS19 967020 INSTRUCTIONS NO. 551-E00 Section Effective Replaces

More information

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16 USER INSTRUCTIONS NAF Setball SF Ball Sector Valves FCD NFENIM4156-00 A4 09/16 Installation Operation Maintenance Experience In Motion Contents SAFETY 3 1 General 3 2 Lifting 4 3 Receiving Inspection 4

More information

DC Master 24/ A

DC Master 24/ A USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015

More information

Condensate Drain Valve AK 45. Original Installation Instructions English

Condensate Drain Valve AK 45. Original Installation Instructions English Condensate Drain Valve AK 45 EN English Original Installation Instructions 810467-03 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure

More information

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump Installation, Operating, Maintenance and Safety Instructions JABSCO 53040 & 5304-Series 40 SIZE UTILITY Pump TO OBTAIN THE BEST PERFORMANCE FROM YOUR JABSCO PUMP PLEASE READ THESE INSTRUCTIONS CAREFULLY

More information

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin INDUSTRY PROCESS AND AUTOMATION SOLUTIONS Technical Bulletin Guidelines for selection of planetary gear units of the 300- INDUSTRIAL series for installation in hazardous areas, classified by Directive

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION 770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the

More information

E Range Heavy Duty Pumps. Benchmark for Reliability

E Range Heavy Duty Pumps. Benchmark for Reliability MONOFLO National Oilwell Varco E Range Heavy Duty Pumps Benchmark for Reliability E Range Pumps Models E032 and below 1. Rotors manufactured in-house to ensure quality standard and exotic materials to

More information

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance. 1. Storage LARSEN & TOUBRO LIMITED Page 1 of 5 1.1. All valves are to be stored in fully open position, in order to protect the sphere surface and soft valve seats. 1.2. Before shipping, the inlet and

More information

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS Address all communications and shipments to: FEDERAL SIGNAL CORPORATION Industrial Systems Group 2645 Federal

More information

N G 3 S p r i n g B r a k e s

N G 3 S p r i n g B r a k e s C o m m e r c i a l V e h i c l e S y s t e m s P r o d u c t M a n u a l N G 3 S p r i n g B r a k e s R ationalised Units for S-Cam Applications P r o d u c t M a n u a l Disclaimer The information contained

More information

PRECISION UK Ltd DUPLEX AGSS PLANT

PRECISION UK Ltd DUPLEX AGSS PLANT DUPLEX AGSS PLANT Contents Page Section Page Product Description General 3 AGSS Plant 3 AGSS Remote Switch 3 Operation General 4 Safety General 5 Installation General 5 Mechanical 5 Electrical 7 Wiring

More information

SB ISS.04. Operation Manual AGMDPRO Automatic Spray Gun

SB ISS.04. Operation Manual AGMDPRO Automatic Spray Gun EN SB-2-991 ISS.04 Operation Manual AGMDPRO Automatic Spray Gun Table of Contents Topic Page Specification and Materials of Construction 3 EC Declaration of Conformity 3 Safety Precautions 4 Model Part

More information

GT-200 GATE VALVES PN16, Screwed end

GT-200 GATE VALVES PN16, Screwed end Document No. : MD-QO-04-281 Date : 2009/07 /17 Version : 1.0 GT-200 GATE VALVES PN16, Screwed end USER MANUAL Modentic Industrial Corporation 14F-1,No.57Taya Rd.,Taichung,Taiwan,R.O.C. Email:modentic@ms9.hinet.net

More information

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes User Guide IM/TORBAR-EN Rev. D Torbar The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement, gas and liquid

More information

250L Cartridge Dual Seal

250L Cartridge Dual Seal INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 250L Cartridge Dual Seal Installation, Operation and Maintenance Instructions TABLE OF CONTENTS 1.0 Cautions...2 2.0 Transport and Storage...2 3.0 Description...2

More information

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 770

More information

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15 USER INSTRUCTIONS NAF Trunnball DL Ball Valves FCD NFENIM4168-01-A4 01/15 Installation Operation Maintenance Experience In Motion Contents SAFETY 3 1 General 3 2 Lifting 4 3 Receiving Inspection 4 4 Installation

More information

IP 900 W/KS & IP 900 D/KS

IP 900 W/KS & IP 900 D/KS B W/KS & D/KS Installation and operating instructions We reserve the right to make modifications in the interest of technical development (4) 15975178 GB 04/05 1 pplication reas The submersible waste-water

More information

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual RIGID PENDANT Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K.,

More information

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471 GE Oil & Gas 73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471 Instruction Manual GE Data Classification: Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC

More information

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual Bray/ VAAS Knife Gate Valve 760/762/765/766/767/768 Series Table of Contents Definition of Terms 1 Safety Instructions 1 Introduction 2 Unpacking 2 Storage 2 Installation 3 Commissioning 3 Cylinder-Operated

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany PTFE-lined Rotary plug valves Series 23e, with packing with lever for 90 operation with worm gear

More information

EH Mechanical Booster Pumps

EH Mechanical Booster Pumps A301-51-880 Issue J Instruction Manual EH Mechanical Booster Pumps Edwards High Vacuum International Manor Royal, Crawley, West Sussex, RH10 2LW, UK Telephone: (01293) 528844 Fax: (01293) 533453 Telex:

More information

IMPORTANT INSTRUCTIONS FOR OPERATION & MAINTENANCE OF

IMPORTANT INSTRUCTIONS FOR OPERATION & MAINTENANCE OF IMPORTANT INSTRUCTIONS FOR OPERATION & MAINTENANCE OF CONVEYORS EASIKIT 300 EASIKIT 450 EASIKIT 600, 900, 1200 & 1500 The manufacturer does not accept responsibility for any loss, damage to other equipment,

More information

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions 1170650/3 IM-P117-17 ST Issue 3 MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions 1 General safety information 2 General product information

More information

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual www.sameng.co.za (011) 823 4250 Proud Manufacturers of SAMCO Pumps Contents INTRODUCTION 3 LOCATION OF UNIT 3 INSTALLATION

More information

JABSCO & Series 1½ 80 SIZE UTILITY Pump

JABSCO & Series 1½ 80 SIZE UTILITY Pump DOC271/98/01 Installation, Operating, Maintenance & Safety Instructions for JABSCO 53080 & 53081-Series 1½ 80 SIZE UTILITY Pump TO OBTAIN THE BEST PERFORMANCE FROM YOUR JABSCO PUMP PLEASE READ THESE INSTRUCTIONS

More information

VEM motors Thurm GmbH

VEM motors Thurm GmbH VEM motors Thurm GmbH Installation, Operating and Maintenance Instructions Single-Phase Squirrel-Cage Induction Motors, Standard Version March 2005 1. General To avoid damage to the motors and equipment

More information

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE   Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT TECHNOLOGIES ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT Enjoy the peace of mind ESS-ESD PRODUCT CATALOGUE CORE VALUES PEACE OF MIND EFFICIENCY FAIRNESS RESPONSIBILITY CUSTOMER ORIENTATION GROWING DEVELOPED

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

HILLSTONE DC LOAD BANK

HILLSTONE DC LOAD BANK OPERATING MANUAL for HILLSTONE DC LOAD BANK Type ref. HLD 240 480 100 Serial No. M36771 ISSUE 1 1 CONTENTS Introduction page 3 Safety Considerations page 3 Connecting procedure page 4 Operating instructions

More information

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2562179B REV. B 818 Printed in USA 2013-2018 Federal Signal Corporation. All rights reserved. Limited Warranty

More information

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions 4034450/9 IM-P403-15 AB Issue 9 BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions 1. Safety information 2. Application 3. Technical data 4. Operation 5. Installation 6. Rotating

More information

Operation Manual BINKS 460 Automatic Spray Gun

Operation Manual BINKS 460 Automatic Spray Gun SB-E-2-150 ISS.01 Operation Manual BINKS 460 Automatic Spray Gun E P 1 12 1 Operation Manual 460 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this equipment

More information

Label Information: FPS75 FPS80 Cranking Warning Label

Label Information: FPS75 FPS80 Cranking Warning Label FLAMEPROOF STARTER MOTOR FPS75 & FPS80 PRODUCT DATA SHEET: PDS 7117 -ISSUE 4 DESCRIPTION FPS75 & FPS80 starter motors are suitable for Zone 1 hazardous areas where explosive gases occur (ATEX directive

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

Pressure and Temperature Switches

Pressure and Temperature Switches Pressure and Temperature Switches Model 4140 Typical applications Suitable for industrial and marine applications Providing protection and safety of: --Diesel engines --Compressors --Pumps --Transmissions

More information

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS VARIFUEL2 140-65 MAINTENANCE AND REPAIR INSTRUCTIONS MOTORTECH Gas Regulation P/N 01.50.008-140-65-EN Rev. 06/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and reproduction

More information

HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE

HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE Ref: WCOI.041 Date: June 2015 Issue: 4 Page Description CONTENTS 1 Introduction Training Requirements 2 General Safety 3 C-RAD Wrench Models Covered

More information

Fisher 2052 Diaphragm Rotary Actuator

Fisher 2052 Diaphragm Rotary Actuator Instruction Manual 2052 Actuator Fisher 2052 Diaphragm Rotary Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 4 Installation... 4 Actuator Mounting and Changing

More information

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES TABLE OF CONTENTS GENERAL SERIES 854(TYPICAL EXPLODED VIEW) COMPONENT LIST INTRODUCTION TO AVK/GLENFIELD SERIES

More information

COMPABLOC. Cb Cb Cb 1504 Installation and maintenance. These instructions should be given to the end user GN

COMPABLOC. Cb Cb Cb 1504 Installation and maintenance. These instructions should be given to the end user GN Réf. 3092-4.33 / a - 2.99 8 7 32 08 67 32 84 68 96 These instructions should be given to the end user 4 80 64 70 30 3 3 39 8 44 66 92 2 4 3 3 309 42 COMPABLOC - Installation and maintenance GN 0090 INSTALLATION

More information

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS VARIFUEL2 200-120 MAINTENANCE AND REPAIR INSTRUCTIONS MOTORTECH Gas Regulation P/N 01.50.008-200-120-EN Rev. 06/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and reproduction

More information

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS PRODUCT SERVICE MANUAL BK6DHZ(C)-250, 275, 312 and 400 PUMPS WARNING This manual, and the GENERAL INSTRUCTION MANUAL, SRM00046, should be read thoroughly prior to pump installation, operation or maintenance.

More information

HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: , , , ,

HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: , , , , HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: 7631700, 7631705, 7631710, 7631715, 7631720 OPERATION & MAINTENANCE INSTRUCTIONS LS0316 INTRODUCTION Thank you for purchasing this CLARKE

More information

IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds

More information

Yarway Que - Temp Desuperheater Standard-/heavy Duty Installation and maintenance Instructions

Yarway Que - Temp Desuperheater Standard-/heavy Duty Installation and maintenance Instructions Before installation these instructions must be fully read and understood Model 33 / 43 Installation of the Que - Temp Desuperheater Model 13 / 23 Before installation, check the Que - Temp Desuperheater

More information

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Date of Issue: 04 August 2010 Page 1 of 27 QF 80: Issue 2 WARNING! BEFORE ANY INSTALLATION AND MAINTENANCE WORK CAN COMMENCE ENSURE THE VALVE AND SURROUNDING

More information