Upblast Spun Aluminum Exhausters
|
|
- Deirdre Woods
- 5 years ago
- Views:
Transcription
1 MARCH 2015 Upblast pun Aluminum Exhausters DUB Direct & BRM Belt Drive eries Canarm certifies that the BRM & DUB eries shown herein are licensed to bear the AMCA eal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publications 211 & 311and comply with the requirements of the AMCA Certified Ratings Programme. WARRANTY Canarm Air Moving Products are guaranteed for a period of one year against manufacturing defects in material and workmanship when operating under normal conditions. Liability is limited to the replacement of defective parts. Labour and transportation costs are not included. If a replacement is warranted the following MUT be provided: 1. Model of equipment 2. Date of manufacture 3. Original invoice reference number(s) CANARM LTD. Corporate Office / HVAC Manufacturing Facility 2157 Parkedale Ave., PO Box 367 Brockville, ON N4B 2Z3 Canada Tel: Fax: hvacsales@canarm.ca
2 T BRM-13 Max RPM Motor: Max HP - 1/2 Max Frame - 56T CFM 0" P 0.25" P 0.5" P 0.75" P 1" P 1.25" P RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP BRM-15 Max RPM Motor: Max HP - 1 Max Frame - 145T CFM 0" P 0.25" P 0.5" P 0.75" P 1" P 1.25" P 1.5" P 1.75" P 2" P I CONVERION FACTOR: CFM x = L/s P x = kpa UBJECT TO CHANGE WITHOUT NOTICE
3 T BRM-18 Max RPM Motor: Max HP - 2 Max Frame - 145T CFM 0" P 0.25" P 0.5" P 0.75" P 1" P 1.25" P 1.5" P 1.75" P 2" P BRM-24 Max RPM Motor: Max HP - 5 Max Frame - 182T CFM 0" P 0.25" P 0.5" P 0.75" P 1" P 1.25" P 1.5" P 1.75" P 2" P UBJECT TO CHANGE WITHOUT NOTICE
4 T BRM-30 Max RPM Motor: Max HP - 5 Max Frame - 182T CFM 0" P 0.25" P 0.5" P 0.75" P 1" P 1.25" P 1.5" P 1.75" P 2" P 2.25" P 2.5" P RPM ONE BHP RPM ONE BHP UBJECT TO CHANGE WITHOUT NOTICE
5 T How to elect a Direct Drive Blower 1. Locate your system characteristics (CFM & P) on the chart with the blower performance curves. 2. Move up the system curve to intersect the closest blower performance curve. That is the performance (CFM & P) that the blower will provide at full speed. 3. Note the CFM. 4. The speed reduction required to operate at the desired CFM is 1 less the ratio of the full speed CFM to the desired CFM. Example: Required in. W.G. (ref. DUB-12 to DUB-30 curves) 1. Locate in. W.G. on the chart (pt. 1). 2. Move up the chart, parallel to the system curves (follow the arrow), to intersect the 1st blower curve (DUB-30). The intersection point, (pt. 2), in W.G. is the performance that the DUB-30 will deliver at full RPM. 3. To deliver the desired 1000 CFM, using the speed controller, reduce the RPM to attain the required 1000 CFM. In this case, the required reduction is 1 - (required CFM / full speed CFM) = 1 - (1000/1175) = 15%. DUB-12 Max RPM Motor: 1/7 HP CFM 0" P 0.125" P 0.25" P 0.375" P 0.5" P 0.625" P RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP (ee above) DUB-30 Max RPM Motor: 1/4 HP CFM 0" P 0.125" P 0.25" P 0.375" P 0.5" P 0.625" P 0.75" P 1" P 1.25" P UBJECT TO CHANGE WITHOUT NOTICE
6 T DUB-33 Max RPM Motor: 1/3 HP CFM 0" P 0.125" P 0.25" P 0.375" P 0.5" P 0.625" P 0.75" P.875" P 1" P 1.125" P 1.25" P RPM ONE BHP RPM ONE BHP DUB-50 Max RPM Motor: 1/2 HP CFM 0" P 0.25" P 0.5" P 0.75" P 1" P 1.25" P 1.5" P 1.75" P RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP RPM ONE BHP DUB-85 Max RPM Motor: 3/4 HP CFM 0" P 0.25" P 0.5" P 0.75" P 1" P 1.25" P 1.5" P 1.75" P 2" P Performance shown is for installation Type A; Free Inlet, Free Outlet. UBJECT TO CHANGE WITHOUT NOTICE
7
200, 9200 & 9200-VIB SERIES
DUCT VENTILATION 200 SERIES Indoor Applications, Insulated or Non-Insulated 9200 SERIES Heavy duty, Insulated Indoor or Outdoor Applications SUBJECT TO CHANGE WITHOUT NOTICE - 04/7 Optional motor, drive
More informationØ5/16" HOLES FOR FASTENING TO CURB
SIDE INTKE SUPPLY UNIT / SIDE INTKE GLVNIZED SUPPLY UNIT OPERTION INSTRUCTIONS ND PRTS MNUL SIS SERIES MODELS: SIS-9, SIS-10, SIS-12, SIS-15, SIS-18, SIS-20 SIG SERIES MODEL: SIG-9, SIG-10, SIG-12, SIG-15
More informationINSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS
SPUN ALUMINUM EXHAUSTER OPERATION INSTRUCTIONS AND PARTS MANUAL READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions
More informationCentrifugal Cabinet Fans Model BCF Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or
More informationJet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY
Jet Fans Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY All Leader Fan products are guaranteed to be free from defects of workmanship or material and to function satisfactorily when properly
More informationPropeller Hooded Roof Fans
Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH
INSTALLATION INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH The purpose of this manual is to aid in the proper installation and operation of the fans. These
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS
INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended
More informationAir Measuring Products AMD AMS IAQ
Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the
More informationCentrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan
Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency
More informationBDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T
DIDW CENTRIFUGAL FAN with Backward Wheel BDB 0 BDB 0 is DIDW centrifugal fan with high efficiency nonoverloading backward curved impeller. The wheel of BDB 0 is made of cold rolled sheet steel with polyester
More informationVDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS
VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS SECTION 11 OPTIONAL ACCESSORIES VXDAF filter sections are insulated and supplied with 1 framed aluminum mesh filter.
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the
More informationLINEA Low Discharge Roof Exhausters
LINEA Low Discharge Roof Exhausters TECHNICAL SPECIFICATIONS BULLETIN LF18 PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION
More informationInsulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.
R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and
More informationTubular Centrifugal Fans
Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,
More informationCentrifugal Filtered Supply Fans
Centrifugal Filtered Supply Fans Model KSF Application/Construction Options/Accessories Construction Features Performance/Dimensions NFPA96 Installation/Common TXB Series Restaurant Exhauster Additional
More informationSTATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS
STATIONARY LOUVERS 14 15 STATIONARY LOUVER STATIONARY LOUVER SSL - 100 SSL SERIES SSL SERIES [SSL - 100, SSL - 110, SSL - 120] Air Performance Pressure Drop SSL - 100 Stationary Louver is a weather louver
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP
INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP The purpose of this manual is to aid in the proper installation and operation of the fans.
More informationInsulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)
R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced
More informationInsulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel
Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and
More informationAMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty
MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading
More informationforward curved inline duct blowers
Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)
More informationBulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS
Bulletin BCF 10 DESIGN 10A BACKWARD INCLINED WHEELS Proven Reliability in Industrial Environments and Corrosive Atmospheres Design 10A s with Backward Inclined Wheels Chicago s Design 10A is a rugged multi-purpose
More informationThermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed
Application The is a low leakage thermally insulated damper with extruded airfoil blades. features broken blade which minimized the transfer of thermal energy and reduce condensation. It s also IECC (International
More informationFan Efficiency Grades and System Effect and Their Effects on HVAC Systems
Fan Efficiency Grades and System Effect and Their Effects on HVAC Systems Matt Spink, P.E. Greenheck Fan Corporation Learning Objectives Understanding Fan Efficiency Grades (FEG) Selection of fans within
More informationMODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN
R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial
More informationMODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER
MODEL CWD MODEL FEATURES Exhaust air up to 3,360 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationMODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS
Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except
More informationThermal Isolation. Break
Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade will minimize the transfer of thermal energy and reduces condensation.it
More informationMODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN
R BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and
More informationTwin City Fan & Blower
Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationK SERIES SIDEWALL PROPELLER FANS
K SERIES S Models LWBK/LMBK and LRBK/LNBK K SERIES S The Carnes Sidewall Propeller Fan series Models LW/LM and LR/LN have been designed for quiet and efficient air flow performance with the lowest possible
More informationAMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options
Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes
More informationUTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.
UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most
More informationCentrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...
More informationAMD-33 Air Measuring Station with VCD-33 Control Damper
Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
More informationMODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS
Model FF Model FFC MODEL FF FEATURES Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation Speed
More informationTURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV
TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the
More informationYour Clean Air Source!
Direct Drive Your Clean Air Source! HIGH QUALITY... HIGH FFICINCY... VRSATILITY stablished in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial
More informationAir Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV
Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one
More informationBelt Drive Centrifugal Roof Exhauster Model PV
Belt Drive Centrifugal Roof Exhauster Model PV Model PV belt drive fans are centrifugal power roof ventilators designed for exhausting clean air. Capacities up to 40,608 CFM and up to 2 inch static pressure.
More informationTURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE
TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.
More informationVCD-23 Low Leakage CONTROL DAMPER
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.
More informationINDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS
INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with
More informationFADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.
January 2008 FADE0108 Fantech, Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA
More informationBaked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)
Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure
More informationCBI JET SERIES. Corrosive. Backward. Inclined. Special Design for: ! Research Centers. ! Laboratory Hood Exhaust. ! Industrial Fume Exhaust
CBI JET SERIES Corrosive Backward Inclined Special Design for:! Research Centers! Laboratory Hood Exhaust! Industrial Fume Exhaust! Waste Water Treatment! Roof or Duct Mounted CBI JET Series Characteristics
More informationMixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data
Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8
More informationBELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City
More informationThe Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP
The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed
More informationBulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A
Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Quieter, More Efficient Airfoil Fans for Commercial and Light Industrial Applications Design 10A Fans with Airfoil Wheels Fourteen Sizes to 80" Volumes
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company
More informationAir Measuring Products. AMS Thermal Dispersion Pressure Differential
Air Measuring Products AMS Thermal Dispersion Pressure Differential August 2014 1 Airflow Measuring Technologies Greenheck airflow measuring products are available with either differential pressure based
More informationCONSTRUCTION FEATURES AND OPTIONS
MODEL SQD & esqd MODEL FEATURES Exhaust air up to 2,8 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION
More informationPhoenix Manufacturing, Inc E. Roeser Rd. Phoenix, AZ phoenixmanufacturing.com
3655 E. Roeser Rd. Phoenix, AZ 85040 phoenixmanufacturing.com 602-437-1034 MODELS: SPECIFICATION DATA INDUSTRIAL AEROCOOL 12 & 8 MODELS ID/IS 500 w/ WS080 or WS100 or WS144 ID/IS 601 w/ WS080 or WS100
More informationAXCL. Inline Bifurcated Fiberglass Centrifugal Blower. Other Quality Corrosion Resistant Fans Available from M.K. Plastics Corporation: ABOUT...
AXCL FRP FANS AXCL Inline Bifurcated Fiberglass Centrifugal Blower We are pleased to provide you with this Engineering brochure for the AXCL Inline Bifurcated Centrifugal Fiberglass Blower. This information
More informationSPECIFICATIONS & SUBMITTAL DATA
SPECIFICATIONS & SUBMITTAL DATA The commercial Industrial Series by Aerocool cools better and requires less maintenance than conventional Aspen coolers. Aerocool Industrial Evaporative Coolers Feature:
More informationPERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN
PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN HVI PERFORMANCE ELECTRICAL & WEIGHT 6" Duct 0.1 Ps - Static Pressure (inh2o) 0.25 Ps Sound (Sones) Power (Watts) Efficacy (CFM/Watt) Volts
More informationCENTREX INLINER Centrifugal Inline Fans
CENTREX INLINER Centrifugal Inline Fans TECHNICAL SPECIFICATIONS BULLETIN SX8 PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION
More informationInline and Roof Mounted Fans
CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive
More informationTwin City Fan & Blower
BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE
More informationBulletin REXJR05 CENTREX REX JR. Model: REXJR Direct Drive Centrifugal Inline Fans
Bulletin REXJR05 CENTREX REX JR. Model: REXJR Direct Drive Centrifugal Inline Fans Centrifugal Inline Fans Introduction CERTIFIED RATINGS Centrifugal Inline Fans PennBarry certifies that the Centrex REX
More informationHazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual
Operating Instructions & Parts Manual EN Hazardous Location Direct-Drive Exhaust Fans Models 10D996 thru 10D999, 10E001 thru 10E007, 10E009 thru 10E020, 32ZN53 and 32ZN54 474904 PLEASE READ AND SAVE THESE
More informationHCD-230 Industrial Control Damper
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationMODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS
MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as restrooms,
More informationType VA Vanax Fans. Models VA, VAD, & VAB
Type VA Vanax Fans Models VA, VAD, & VAB Type VA Direct Drive Model VA Sizes 6 through 10 207 to 1,811 CFM Static Pressure to 1-1/2 Type VAB Belt Drive Model VAB Sizes 12 through 48 1,004 to 47,176 CFM
More informationCentrifugal Spun Aluminum Products
Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview
More informationSPECIFICATIONS & SUBMITTAL DATA
SPECIFICATIONS & SUBMITTAL DATA The commercial Industrial Series by Aerocool cools better and requires less maintenance than conventional Aspen coolers. Aerocool Industrial Evaporative Coolers Feature:
More informationMODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS
MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive
More informationCentrifugal Spun Aluminum Products
Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview
More informationDirect Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast
Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall Roof Downblast Models LPD & RED LPD Applications/Construction LPD Performance/Dimensions RED Applications/Construction RED Performance/Dimensions
More informationZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS
ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive
More informationLDV / LDVQ 5000 AIR VOLUME CONTROL VALVE INSTALLATION MANUAL. Date: 02 / 10 Reference # : F-36. w w w. p r i c e - h v a c. c o m
LDV / LDVQ 5000 AIR VOLUME CONTROL VALVE Date: 02 / 10 Reference # : F-36 General Description The LDV/LDVQ 5000 is supplied with the duct, damper, and sensor constructed of Type 316 stainless steel. The
More informationMODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN
TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside
More informationVCD-23. Flange Options. Size Limitations
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators
More informationMODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS
R MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as
More informationSeries TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction
DIRECT DRIVEN Series TDA Construction Double flanged casing is produced in mild steel or galvanised steel, available in short and long cased. The impeller having manually adjustable pitch blades is made
More informationBelt Drive Propeller Fans. Catalog GS Series Catalog HC Series JANUARY I j(1
Belt Drive Propeller Fans Catalog GS Series Catalog HC Series JANUARY 2000 I I j(1 Quietaire GS Series Fans GS SERIES FEATURES QUALITY CONSTRUCTION GS Series fans have rugged, unitized construction with
More informationModel VCD-20 3V CONTROL DAMPER
R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium
More informationYour Clean Air Source!
Direct Drive Your Clean Air Source! HIGH QUALITY... HIGH FFICINCY... VRSATILITY stablished in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial
More informationModel VCD-43 Extruded Airfoil Blade Control Damper
Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure
More informationMODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE
BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit
More informationINLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK
INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the
More informationFRP Fans: CLUB Series Performance and Technical Information
FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field
More informationsidewall propeller fans L 1.07 models lc, l2 & l3 january 2007 belt drive - exhaust & supply three levels of construction
R SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Jenco, Div. of Soler & Palau Ventilation Group, certifies that the models shown herein are licensed to bear the AMCA Seal. The
More informationID-141x 12-Gauge Hat Channel Industrial Damper
ID-141x 12-Gauge Hat Channel Industrial Damper Product Bulletin Code No. LIT-12011355 Issued June 12, 2013 Supersedes March 13, 2012 Since 1905, Johnson Controls has developed and refined air control products
More informationModel VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.
Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted
More informationRM-1200 Slim Round Control Damper
RM-1200 Slim Round Control Damper Product Bulletin Code No. LIT-12011358 Issued June 16, 2008 Since 1905, Johnson Controls has developed and refined air control products by providing the highest quality
More informationIndustry best 5 year fan housing warranty, 1 year motor warranty
MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2
More informationCEILING & INLINE/CABINET VENTILATORS
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 MARCH 2018 CEILING & INLINE VENTILATORS OVERVIEW T I TL T-Series
More informationMODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER
MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading
More informationPropeller Fan BE Series
Propeller Fan BE Series ENCLOSED BELT DRIVEN WALL EXHAUST FAN THESE LOW PRESSURE BELT DRIVEN FANS ARE IDEALLY SUITED FOR VENTILATION OF UNDERGROUND GARAGES OF APARTMENT BUILDINGS, WAREHOUSES, PUBLIC BUILDINGS,
More informationCentrifugal Spun Aluminum Products
Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview
More informationModel SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation
Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control
More informationMODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS
S CSF & LSF Model CSF Hooded Design FEATURES Supply air to over 13,000 CFM in static pressure capabilities to 2 w.g. Heavy-galvanized construction Belt drives permit easy performance adjustments when needed
More informationTURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series
TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 March 2018 CEILING & INLINE VENTILATORS Overview T I TL Twin City Fan & Blower s T-Series Ceiling and TL-Series
More information