1 > Alpha Industrial Power Total Power Solutions by ALPHA INDUSTRIAL POWER

2

3 Alpha Industrial Power > Alpha Power Alpha Industrial Power had been an established power systems integrator and supplier of DC and battery systems for more than 20 years. At Alpha Industrial Power, we continue to implement innovative ideas and advanced technologies, with a focus on providing systems with greater flexibility, added reliability and lower overall costs. Our capabilities extend from feasibility analysis to design, installation and service: a turnkey system solution. Today, with numerous projects installed around the world, Alpha continues to focus on providing the most reliable, innovative and energy efficient industrial powering solutions. > Innovation Alpha Industrial solutions are used anywhere there is a need for clean, reliable, uninterrupted power. Our strength comes from our years of experience and engineering expertise in developing unique systems for specific applications, technologies and regions. Our capabilities extend from feasibility analysis to engineering, design, installation of DC power, AC UPS, generators and renewable energy systems, including on-site project management. Our product line includes: AC Systems UPS Systems and Inverters for industrial utilities and other critical applications. DC Systems Power systems including charger modules, distribution and batteries for critical applications. NiCad Batteries Offering pocket plate vented or low-maintenance design, in clear or translucent cases. Lead Acid Batteries 20-year flooded or valve regulated type, with capacities ranging from 20 to 3000AH. Renewable Energy Solar Power and Hybrid Power Systems for telecom, telemetry, cellular and other remote sites. Enclosures Indoor and outdoor enclosures to house and protect AC or DC equipment. Installation and Services The Alpha Group of companies offers nationwide engineering and installation of DC power, AC UPS, generators and renewable energy systems, including on-site project management. > Sustainability Energy efficiency is a critical component of powering any system. More than that, it makes economic sense. Alpha s next generation High Performance powering systems enable operators to focus on energy efficiency while assuring unprecedented reliability, extended battery runtimes and increased flexibility. > Collaboration Working with customers on solving their powering challenges makes us successful, and hundreds of dedicated Alpha engineers, technicians, craftspeople and field specialists share this focus. Our highly motivated and talented people create proactive solutions that help shape the future of the industry and Alpha itself - an organization where people and power come together.

4

5 Table of Contents > Engineered AC Systems 5-11 Alpha Astra Series 6 MX Series 11 > Integrated DC Systems 13 > Chargers Spectra Charger 16 Cordex 3.3kW System 18 P45 Battery Charger 19 > Nickel Cadmium Batteries NiCad Clear Case 22 NiCad Translucent Case 25 NiCad Range Lomain 31 > Flooded Lead Acid Batteries AlphaCell OPzS 36 AlphaCell OGi 37 AlphaCell SMU-HR 38 AlphaCell SMU-F 39 AlphaCell SMU-C 40 AlphaCell SMU-M 42 > Battery Rack Systems 45 > Specialized Systems 47 > Selecting A System 49 3 Table of Contents

6

7 Engineered AC Systems Alpha Industrial Power products deploy advanced power electronics technology, providing an output range from 5 to 650kVA (parallel redundancy). Our UPS systems are designed and manufactured to meet specialized applications to ensure reliable protection of critical loads in hospitals, utilities, telecommunications and other applications. In addition to our range of standard Uninterruptible Power Supplies (UPS), Alpha Industrial Power designs ASTRA customized systems (e.g. rectifiers, inverters, UPS) to meet customer specifications. These products are commonly used in power plants, petrochemical plants, gas and oil pipelines, railways, subways, offshore platforms and cruise ships. Alpha Industrial Power application engineers will work with you to develop a system to meet your powering needs. > Our systems feature: Dual microprocessor-controlled units Online system double conversion Output isolating transformers Input-output insulation (operating from inverter) Manual bypass Low harmonic distortion reflected to the mains Automatic battery tests every month Power factor corrected rectifier input Temperature-compensated rectifier High crest factor Capability of supplying distorted loads, containing output voltage distortion Parallel redundant configuration of up to 6 units RS 232 to RS 485 serial interfaces, SNMP, control software for Windows Instantaneous high overload capability High MTBF (> h) and low MTTR (<0.5h) High efficiency starting at 25% of load Compact and easy installation and maintenance Front accessibility User-friendly diagnostics 5 Engineered AC Systems Custom UPS AC UPS Novus Micro

8 Alpha Astra Series Industrial Grade UPS System > A complete AC and DC power backup system > State-of-the-art IGBT technology and ergonomics > True online double conversion UPS provides high power quality and reliability > Monitoring panel provides all the necessary information > Ideal for Thermal Power Plants, Petrochemical Plants, Steel Works and other mission critical applications AUTOLUX 20 to 200kVA mprocessor Controlled voltage regulator for lighting control application Astra Industrial AC and DC Power systems are engineered to supply clean continuous power in conditions ranging from everyday power fluctuations to catastrophic power failure. Applications include: Thermal Power Plants Petrochemical Plants and Steel Works 6 Engineered AC Systems Systems are designed with state-of-the-art IGBT technology and ergonomics, providing a complete AC and DC power backup system. True online double conversion Uninterruptible Power Supplies (UPS) provide high power quality and reliability. The LCD monitoring panel provides all necessary information on an easy to understand front mimic panel. Ideal applications for Alpha Industrial Power systems include thermal power plants, petrochemical plants, steel-works, naval civil applications, naval military applications, off-shore platforms, energy control, civil installations and railway infrastructure. 100kVA 3Ph. UPS ENELPOWER Power stations ITALY 110/220Vdc Rectifiers 30kVA 1Ph. Inverter GENERAL ELECTRIC Port Talbot UK Naval Civil Applications 110Vdc Rectifiers 30kVA 1Ph. Inverters IRASCO Refineries Iran 3500A Rectifiers PIRELLI Steel Chord Plants Off-Shore Platforms 250kVA 115Vac 3Ph. UPS LITTON Cruise Ships USA 24Vdc Rectifiers 24Vdc Stabilizers SASP OFFSHORE ENG. Clara Complex Adriatic Sea 160kVA Frequency converters TIRRENIA and MINOAN Ferries Italy/Greece 10kVA UPS Systems SAIPEM SAIPEM 7000 Drilling Ship

9 Alpha Astra Series Industrial Grade UPS System > Power range: 120/240Vdc 65 to 1100A > Full digital control > Open code software: system engineering adapts the basic C code to the application through a userfriendly interface (no programming skills required) > Adaptable to all input voltages > Frequency (50 and 60Hz) self-adapting > Adaptable to all output voltages and currents > Automatic battery recharge (UI-DIN41733, I1 I2 U, U1 U2 I) > Manual battery recharge Alpha Astra Series RCN 120 and 240Vdc 65A 125A 225A 350A Electrical Input Voltage: 380/400/415Vac, ±15%, 3Wires (other voltage on request) Input Frequency: 50+60Hz, ±5Hz Input Short Circuit Current (@ 400Vac, IEC Standard): 10kA rms (others on request) 120Vdc Max Input Power Vin=400V, Load 100%: 12.8kVA 24.6kVA 44.3kVA 68.9kVA 240Vdc Max Input Power Vin=400V, Load 100%: 25.6kVA 49.2kVA 88.6kVA 138kVA Max Input Power Nominal Load (THD%): 27%, 12% with 12 pulses bridge with electronic sharing (on request) or with input THD filter (on request) Input Power Factor (With nominal voltage, 100% load): 0.75 (without manual charge) 120Vdc Nominal Output Voltage: 120Vdc ( ) 240Vdc Nominal Output Voltage: 240Vdc ( ) Floating V/Cell for lead battery (adjustable), V/Cell for NiCad battery (adjustable) Output Voltage Boost V/Cell for lead battery (adjustable), V/Cell for NiCad battery (adjustable) (Vac): Equalizing Up to 2.7 V/Cell for lead battery, up to 1.7 V/Cell for NiCad battery (manual charge) Forced boost push button (on request), Thermal compensation for sealed lead battery (on request) Output Ripple: 2%rms (1%rms on request) Overload Capability: 110% for 20min / 120% for 10sec Battery Recharging System: DIN IU with ammetric discrimination for vented lead acid and NiCad battery Heat Nominal Load and Voltage (120Vdc): 0.6kW, 34BTU/min 1.13kW, 64BTU/min 2.03kW, 116BTU/min 3.15kW, 180BTU/min Heat Nominal Load and Voltage (240Vdc): 1.2kW, 68BTU/min 2.25kW, 128BTU/min 4.06kW, 231BTU/min 6.3kW, 359BTU/min Parallelability: Units decoupled by diodes with natural load sharing (on request) 7 Engineered AC Systems 120Vdc Efficiency: 25%, 50%, 75%, 100% 68, 83, 88, 93 69, 84, 89, 93 70, 84, 90, 93 70, 85, 90, Vdc Efficiency: 25%, 50%, 75%, 100% 68, 83, 88, 93 69, 84, 89, 93 70, 85, 90, 94 72, 86, 91, 94 Cable Wiring: Insulation 450/750V Uo/U, 70 to 160 C, CEI 20-22, IEC (450/750V Uo/U, 90 to 250 C, CEI 20-22, CEI 20-38, IEC on request) Flat cables for low voltage signals between PCBs are used Environmental Acoustic Noise Level: <60dBA (according EN 50091) <62dBA (according EN 50091) EMI: EN (CE Label) Restricted Operating Temperature: -10 to 40 C / 14 to 104 F Storage Temperature: -20 to 70 C / -4 to 158 F Relative Humidity: 0 to 95% non-condensing Ventilation: Forced for rectifier bridge (redundant on request) Elevation (mt. above sea level): <2000 (derating -0.05% / mt) Mechanical Protection Degree (IEC529): IP 20 (other on request) Painting Color and Type: RAL 7035 (Gray), 60µm, 40 gloss (others on request) Dimensions 120Vdc L x W x H (in/mm): 23.8 x 24.2 x 70.9 / 605 x 615 x x 24.2 x 82.7 / 805 x 615 x 2100 Weight 120Vdc (lb/kg): / / / / 800 Dimensions 240Vdc L x W x H (in/mm): 24.2 x 24.2 x 70.9 / 615 x 615 x x 24.2 x 82.7 / 805 x 615 x x 32.1 x 82.7 / 805 x 815 x 2100 Weight 240Vdc (lb/kg): / / / / 900 Input/Output Cable Connection: Bottom side (top side on request) Transport: Base provided for forklift handling (lifting belts and load balancing hooks available - on request) Transport Mechanical Stress: EN Restricted Installation (in/mm): 7.9 / 200 from wall (less on request), 11.8 / 300 from ceiling, air inlet from the front, air outlet from the top and rear sides Accessibility: Front and rear (not rear access - on request with cabinet extension)

10 Alpha Astra Series Industrial Grade UPS System > Power range: 5 to 3600kVA > Full digital control > Open code software: system engineering adapts the basic C code to the application through a userfriendly interface (no programming skills required) > Adaptable to all input DC standard voltages > Adaptable to all output AC standard voltages > Parallelable up to 6 units > LCD Front Panel + S232 + Free Contact Interface > Compatible with the main communication standards > Compliant to the main industrial standards 8 Engineered AC Systems Alpha Astra Series ITN 120Vdc 10kVA 20kVA 30kVA 60kVA 100kVA 150kVA Electrical Input Voltage: 120Vdc nominal value, min to max range 95 to 170 Nominal Output Power (P.F. 0.8, P.F. 1): 10kVA, 8kW 20kVA, 16kW 30kVA, 24kW 60kVA, 48kW 100kVA, 80kW 150kVA, 120kW Nominal Output Voltage: 380/400/415Vac (adjustable ±5%) 3PH + N 4 wires (208 or 440 on request) Nominal Output Current (P.F. 0.8, P.F. 1): 14.5A, 11.6A 29A, 23.2A 43.3A, 34.7A 87A, 70A 145A, 116A 217A, 174A Output Harmonic Distorsion (THD): <3% linear load, <6% non linear load (75% N.P. and CF 3:1) Overload Capability Inverter 110% Pn for 2h, 125% Pn for 10, 150% ln for 10, 200% ln for 100ms (PF=0.8): Bypass 150% Pn continuous duty, 200% Pn for 10, 2000% Pn for 1 cycle Bypass Protection By fuses Short Circuit Protection: Current Inverter 200% ln for the first 100ms (AC current limit for distribution fuses intervention) 125% ln for 5 s (according with EN ) Limitation Output Frequency: Nominal 50/60Hz (selectable), inverter sync with mains ±2Hz (selectable) Voltage Static Stability: ±2% Dynamic Stability (50%, 100%) : ±5% with ±2% within 2 cycles, ±8% (±5% on request) with ±2% within 3 cycles Efficiency (25%, 50%, 75%, 100%): 81, 83, 85, 85 82, 84, 85, 86 82, 86, 87, 87 83, 86, 87, 87 Heat Nominal Load and Voltage: Hot Standby: Parallelability: Automatic Static Bypass: Bypass Range Voltage Accepted For Commutation: Frequency 1.41kW, 80BTU/min 2.60kW, 148BTU/min 3.59kW, 204BTU/min 7.17kW, 408BTU/min 2 units max Up to 6 units with electronic sharing Electronic Thyristor Switch Nominal output voltage ±10% (others on request) Nominal output frequency ±2Hz (adjustable) 11.9kW, 680BTU/min Transfer: Sensing and transfer time Cycle, Commutation time 500µs Retransfer: 0 s (controlled), automatic or manual (selectable), block on mains after 6 commutations in 120sec Manual Bypass: With electronic security and without interruption Cable Wiring: 450/750V Uo/u, 70 to 160 C, CEI 20/22, IEC (450/750V Uo/u, 90 to 250 C, CEI 20-22, CEI 20-38, IEC on request) Flat cables for low voltage signals between PCBs are used Environmental Acoustic Noise Level: <62dBA (according EN 50091) <65dBA (according to EN 50091) EMI: EN (CE Label) Restricted Operating Temperature: -10 to 40 C / 14 to 104 F (for T <0 C data can not be readable due to freezing of LCD) Storage Temperature: -20 to 70 C / -4 to 158 F Relative Humidity: 0 to 95% non-condensing Ventilation: Forced (forced redundant on request) Elevation (mt. above sea level): <1000 Power Derating For Elevation: >1000 mt (a.s.l.) 0.05% / mt Mechanical Protection Degree (IEC529): IP 20 (other on request) Painting Color and Type: RAL 7035 (Gray), 60µm, 40 gloss (others on request) Dimensions L x W x H (in/mm): 23.8 x 24.2 x 70.9 / 605 x 615 x x 24.2 x 85.7 / 805 x 615 x x 36 x 82.7 / 805 x 915 x x 63 x 82.7 / 805 x 1600 x kW, 1020BTU/min 35.6 x 70.9 x 82.7 / 905 x 1800 x 2100 Weight (lb/kg): / / / / / / 1080 Input/Output Cable Connection: Bottom side (top side on request) Transport: Base provided for forklift handling (lifting belts and load balancing hooks available - on request) Transport Mechanical Stress: EN Restricted Installation (in/mm): 7.9 / 200 from wall (less on request), 11.8 / 300 from ceiling, air inlet from the front, air outlet from the top and rear Accessibility: Front and rear (not rear access - on request with cabinet extension)

11 Alpha Astra Series Industrial Grade UPS System > Power range: 5 to 3600kVA > Full digital control > Open code software: system engineering adapts the basic C code to the application through a userfriendly interface (no programming skills required) Alpha Astra Series IMN 120Vdc/115Vac/230Vac 10kVA 20kVA 30kVA 60kVA Electrical Input Voltage: 120Vdc nominal value, min to max range 95 to 170 Nominal Output Power (P.F. 0.8, P.F. 1): 10kVA, 8kW 20kVA, 16kW 30kVA, 24kW 60kVA, 48kW Nominal Output Voltage: 115/120Vac (adjustable ±5%) 1PH, 2 wires Nominal Output Current (P.F. 0.8, P.F. 1): 87A, 69.6A 174A, 139A 260A, 208A 521A, 417A Output Harmonic Distorsion (THD): <3% linear load, <6% non linear load (75% N.P. and CF 3:1) Overload Capability Inverter 110% Pn for 2h, 125% Pn for 10, 150% ln for 10, 200% ln for 100ms (PF=0.8): Bypass 150% Pn continuous duty, 200% Pn for 10, 2000% Pn for 1 cycle Bypass Protection By fuses Short Circuit Protection: Current Inverter 200% ln for the first 100ms (AC current limit for distribution fuses intervention) 125% ln for 4.8 s (according with EN ) Limitation Output Frequency: Nominal 50/60Hz (selectable), inverter sync with mains ±2Hz (selectable) Voltage Static Stability: ±1.5% Dynamic Stability (50%, 100%): ±5% with ±2% within 2 cycles, ±8% (±5% on request) with ±2% within 2 cycles Efficiency (25%, 50%, 75%, 100%) : 75, 79, 82, 83 76, 80, 82, 84 80, 82, 83, 85 80, 82, 86, 87 Heat Nominal Load and Voltage: 1.63kW, 92.7BTU/min 3.05kW, 173BTU/min 4.23kW, 240BTU/min 7.17kW, 408BTU/min Hot Standby: 2 units max Parallelability: Up to 6 units with electronic sharing Automatic Static Bypass: Electronic Thyristor Switch Bypass Range Voltage Nominal output voltage ±10% (others on request) Accepted For Commutation: Frequency Nominal output frequency ±2Hz (adjustable) Transfer: Sensing and transfer time Cycle, Commutation time 500µs Retransfer: 0 s (controlled), automatic or manual (selectable), block on mains after 6 commutations in 120sec Manual Bypass: With electronic security and without interruption Cable Wiring: 450/750V Uo/U, 70 to 160 C, CEI 20-22, IEC (450/750V Uo/U, 90 to 250 C, CEI 20-22, CEI 20-38, IEC on request) Flat cables for low voltage signals between PCBs are used 9 Engineered AC Systems Environmental Acoustic Noise Level: <62dBA (according EN 50091) <65dBA (according EN 50091) EMI: EN (CE Label) Restricted Operating Temperature: -10 to 40 C / 14 to 104 F (for T <0 C data can not be readable due to freezing of LCD) Storage Temperature: -20 to 70 C / -4 to 158 F Relative Humidity: 0 to 95% non-condensing Ventilation: Forced (forced redundant on request) Elevation (mt. above sea level): <1000 Power Derating For Elevation: >1000 mt (a.s.l.) 0.05% / mt Mechanical Protection Degree (IEC529): IP 20 (other on request) Painting Color and Type: RAL 7035 (Gray), 60µm, 40 gloss (others on request) Dimensions L x W x H (in/mm): 23.8 x 24.2 x 70.9 / 605 x 615 x x 32.1 x 82.7 / 805 x 815 x x 36 x 82.7 / 905 x 915 x 2100 Weight (lb/kg): / / / / 670 Input/Output Cable Connection: Bottom side (top side on request) Transport: Base provided for forklift handling (lifting belts and load balancing hooks available - on request) Transport Mechanical Stress: EN Restricted Installation (in/mm): 7.9 / 200 from wall (less on request), 11.8 / 300 from ceiling, air inlet from the front, air outlet from the top and rear Accessibility: Front and rear (not rear access - on request with cabinet extension)

12 Alpha Astra Series Industrial Grade UPS System > Adaptable to all input DC standard voltages > Adaptable to all output AC standard voltages > Parallelable up to 6 units > LCD Front Panel + S232 + Free Contact Interface > Compatible with the main communication standards > Compliant to the main industrial standards Alpha Astra Series IMN 240Vdc/115Vac/230Vac 10kVA 20kVA 60kVA 115kVA Electrical Input Voltage: 240Vdc nominal value, min to max range 190 to 330 Nominal Output Power (P.F. 0.8, P.F. 1): 10kVA, 8kW 20kVA, 16kW 60kVA, 48kW 115kVA, 92kW 10 Engineered AC Systems Nominal Output Voltage: 115/120Vac (adjustable ±5%) 1PH, 2 wires Nominal Output Current (P.F. 0.8, P.F. 1): 87A, 69.6A 174A, 139A 521A, 417A 1000A, 800A Output Harmonic Distorsion (THD): <3% linear load, <6% non linear load (75% N.P. and CF 3:1) Overload Capability Inverter 110% Pn for 2h, 125% Pn for 10, 150% ln for 10, 200% ln for 100ms (PF=0.8): Bypass 150% Pn continuous duty, 200% Pn for 10, 2000% Pn for 1 cycle Bypass Protection By fuses Short Circuit Protection: Current Inverter Limitation 200% ln for the first 100ms (AC current limit for distribution fuses intervention) 125% ln for 4.8 s (according with EN ) Output Frequency: Nominal 50/60Hz (selectable), inverter sync with mains ±2Hz (selectable) Voltage Static Stability: ±1.5% Dynamic Stability (50%, 100%): ±5% with ±2% within 2 cycles, ±8% (±5% on request) with ±2% within 2 cycles Efficiency (25%, 50%, 75%, 100%) : 80, 81, 82, 84 80, 81, 83, 85 82, 84, 86, 88 83, 85, 87, 89 Heat Nominal Load and Voltage: 1.4kW, 79.6BTU/min 2.8kW, 159BTU/min 6.5kW, 370BTU/min 11.4kW, 648BTU/min Hot Standby: 2 units max Parallelability: Up to 6 units with electronic sharing Automatic Static Bypass: Electronic Thyristor Switch Bypass Range Voltage Nominal output voltage ±10% (others on request) Accepted For Commutation: Frequency Nominal output frequency ±2Hz (adjustable) Transfer: Sensing and transfer time Cycle, Commutation time 500µs Retransfer: 0 s (controlled), automatic or manual (selectable), block on mains after 6 commutations in 120sec Manual Bypass: With electronic security and without interruption Cable Wiring: 450/750V Uo/U, 70 to 160 C, CEI 20-22, IEC (450/750V Uo/U, 90 to 250 C, CEI 20-22, CEI 20-38, IEC on request) Flat cables for low voltage signals between PCBs are used Environmental Acoustic Noise Level: <62dBA (according EN 50091) <65dBA (according EN 50091) EMI: EN (CE Label) Restricted Operating Temperature: -10 to 40 C / 14 to 104 F (for T <0 C data can not be readable due to freezing of LCD) Storage Temperature: -20 to 70 C / -4 to 158 F Relative Humidity: 0 to 95% non-condensing Ventilation: Forced (forced redundant on request) Elevation (mt. above sea level): <1000 Power Derating For Elevation: >1000 mt (a.s.l.) 0.05% /mt Mechanical Protection Degree (IEC529): IP 20 (other on request) Painting Color and Type: RAL 7035 (Gray), 60µm, 40 gloss (others on request) Dimensions L x W x H (in/mm): 23.8 x 24.2 x 70.9 / 605 x 615 x x 36 x 82.7 / 905 x 915 x 2100 Weight (lb/kg): / / / / 780 Input/Output Cable Connection: Bottom side (top side on request) Transport: Base provided for forklift handling (lifting belts and load balancing hooks available - on request) Transport Mechanical Stress: EN Restricted Installation (in/mm): 7.9 / 200 from wall (less on request), 11.8 / 300 from ceiling, air inlet from the front, air outlet from the top and rear Accessibility: Front and rear (not rear access - on request with cabinet extension)

13 MX Series Rack Mount Power Inverter > Truly redundant N+1 power inverter > Offers the cleanest true sine wave power available > Hotswappable for easy service and maintenance > Extremely lightweight and compact design MX Series - Standard Features General Specifications Models: 12V 24V 32V 48V 66V 108V Waveform: Sinusoidal Sinusoidal Sinusoidal Sinusoidal Sinusoidal Sinusoidal Line Regulation: 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% Load Regulation: 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% Distortion: 1.5% 1.5% 1.5% 1.5% 1.5% 1.5% Frequency: Nominal Nominal Nominal Nominal Nominal Nominal Input Power Voltage: 12V 24V 32V 48V 66V 108V Minimum: /94 System: Maximum: Efficiency 100%): 85% 87% 87% 87% 88% 88% Efficiency 33.3%): 87% 89% 89% 89% 90% 90% Output Power Continuous Power: 1000W 1000W 1000W 1000W 1000W 1000W Surge Power: 2200W 2200W 2200W 2200W 2200W 2200W No Load Power: 20W 20W 20W 20W 20W 20W Output Voltage: 230/117/100V 230/117/100V 230/117/100V 230/117/100V 230/117/100V 230/117/100V Output Current: 4.3/8.6/10 4.3/8.6/10 4.3/8.6/10 4.3/8.6/10 4.3/8.6/10 4.3/8.6/10 Mechanical Dimensions L x W x H (in/mm): 15 x 7 x 7 / 381 x 178 x x 9.97 x 7 / 381 x 253 x x 19 x 7 / 381 x 483 x x 23 x 7 / 381 x 584 x x 23 x 7 / 381 x 584 x 178 Protection Circuitry Over Voltage: Shutoff at maximum input voltage per input conditions Under Voltage: Shutoff at minimum input voltage per input conditions Thermal: 105 C / 221 F internal warning alarm at 5 C / 41 F before shutoff Output Short: Unit shuts off: Circuit breaker protected and electronically limited Environmental Temperature: -25 to 40 C / -13 to 104 F full power, derate at 20% per 10 C / 50 F above 40 C / 104 F Humidity: 5 to 95% non-condensing Elevation: -60 to 3000m / -200 to 10000ft without derating Audible Noise: Less than 45dBA Cooling: 1kW thermostatically controlled forced air Finish: Polyurethane base paint Warranty: One full year parts and labor 15 x 23 x 7 / 381 x 584 x Engineered AC Systems

14

15 Integrated DC Systems Through the integration of our battery systems, battery chargers and AC UPS systems, Alpha Industrial Power is able to provide industrial power solutions for telecommunications, electrical utilities, petrochemical and other large-scale applications. > Battery Systems Because batteries are such a critical link in providing reliable power solutions, Alpha Industrial Power offers a large selection of batteries incorporating several different battery technologies each optimized for specific commercial and industrial applications. Exclusive internal design, unique casing options and extensive testing contribute to industry-leading field performance and extended service life. > Battery Chargers Alpha Industrial Power has addressed the power industry s demand for individually customized, robust and durable industrial microprocessor-controlled battery chargers. More than two decades of aggressive research and development has yielded a charger line that provides complete integration, remote monitoring and enhanced power reliability. > DC Distribution DC Power plants provide clean, consistent power for communications applications. They allow complete control over the entire power system within one single, easy-to-use environment by combining the capabilities of distribution, advanced microprocessor-based supervision and modular rectifiers in a seamless integrated package. 13 Integrated DC Systems

16

17 Chargers Alpha s industrial battery chargers feature a 30-year design life and incorporate digital and power electronics technologies for added efficiency and reliability. The unique SCR rectifier with a double wound isolation transformer and microprocessor provides regulated DC output and currentlimiting capabilities. Our switched mode rectifier/charger provides the best in output regulation and low-noise operation with a compact footprint. > Spectra Single Phase Charger The Alpha Spectra Industrial Battery Charger incorporates the latest digital and power electronics technologies, making it one of the most reliable battery chargers available. The unique SCR rectifier with a double wound isolation transformer provides precisely regulated DC output and current-limiting capabilities. Three different output-filtering configurations are available to match powering requirements. Operates to UL, CSA and EMI standards. Made in the USA. > Cordex 3.3kW, 1 to 3 Phase Charger The Cordex 3.3kW high voltage integrated power system provides the best in efficiency and reliability and meets the power requirements for a variety of system applications. This system is specifically designed to recharge all types of stationary batteries for large utility, petrochemical and industrial uses. The Cordex 3.3kW is a compact 7RU integrated system, with up to three Cordex 1.1kW rectifiers in a 19" shelf available for rack or wall mounting. Local and remote setup, adjustment and control are simple single-step processes via the Cordex CXC touch screen system controller or via ethernet on a standard web browser. Battery management and data logging are standard system features. > P45 Battery Charger The P45 Battery Charger System s various filtering levels are available to match output requirements. Typical MTBF is 100,000 hours and typical MTTR is less than one hour. The charger s graphic interface, with its user-definable controls and alarm set-points, allows for quick and versatile customization. Operates to UL, CE, CSA and EMC standards. 15 Chargers

18 Spectra Charger SCR Automatic Battery Charger > Industrial-grade battery charger > Microprocessor control and digital display > Universal control boards and control disable for tamper-free operation > Online adjustment 16 Chargers Spectra Charger Specifications Electrical AC Input Voltage: 120, 208 or 240V +10%, -12% Phase: 1 Frequency: Power Factor: Efficiency: DC Output Voltage: Current: Continuous Rating: Voltage Regulation: Transient Response: Electrical Noise: Mechanical Dimensions S1 L x W x H (in/mm): Dimensions S2 L x W x H (in/mm): Dimensions S3 L x W x H (in/mm): Enclosure: Environmental 50 or 60Hz ±3Hz 0.8 typical full load 80 to 90% at 50 to 100% load 24, 48 or 130Vdc nominal 6, 12, 20, 25 or 50ADC 110% rated current at max equalize voltage at 50 C / 122 F ±.25% for line, load and temperature <±6% with 20 to 100% step load with battery connected 30m v r m s/32bdrnc weighted maximum on filtered versions (battery eliminator) <2%vrms for 130Vdc output <1%v r ms for 48Vdc output x 19 x 17.5 / 425 x 483 x x 19 x / 425 x 483 x x 19 x 35 / 425 x 483 x 889 NEMA 1 (Standard) Temperature: 0 to 40 C / 32 to 105 F Elevation: Humidity: 1000m / 3000ft without derating 0 to 95% non-condensing Standard Features LCD display High DC voltage shutdown Charger pause 0 to 60 min Push button mode selection Reverse polarity protection AC and DC surge suppressors Sprinkler resistant ventilation Wire protection on field connections UL listed Floor mount legs Stackable enclosure Summary alarm contact relay Summary alarm buzzer AC H/L voltage alarm and AC fail indication H/L DC voltage alarm AC input and DC output circuit breakers Control panel and circuit breakers recessed Bottom/Side cable entry AC, DC, float and equalize indicator lights Field programmable with security levels Compression terminal strip for field wiring Optional Features DC ouput filter Conformal seal on electronic boards Battery eliminator filter Anti-fungus coating Input lightning arrestor Special AC input voltage Remote control panel 19" or 23" relay rack mounting Parallel charging Remote DC voltage sensor Cabinet heater Special AC power connections Local or remote voltage sensor Remote temperature compensation Individual alarm relay contact board (alarm input/output board) CONTROL PANEL W/LED DISPLAY H AC KNOCKOUTS THIS SIDE & BOTTOM DC & SENSOR KNOCKOUTS THIS SIDE & BOTTOM D AC CIRCUIT BREAKER DC CIRCUIT BREAKER W

19 Spectra Charger SCR Automatic Battery Charger > Modular construction for easy maintenance and replacement > Battery eliminator option for use as a DC source without batteries > UL listed and CSA label Spectra Charger ST Series Rating Table Output Voltage 24Vdc 48Vdc 130Vdc Float Voltage Range Equalize Voltage Range 24Vdc to 30Vdc 48Vdc to 60Vdc 120Vdc to 150Vdc ST Model Number Configuration DC Ampere Rating 6A 12A 18A 20A 25A 50A AC Input AC Input Amperes (Nominal): 5A 4A 3A 7A 5A 5A 12A 8A 8A 12A 8A 8A 14A 10A 10A 30A 22A 22A AC Input Circuit Breaker: 10A 10A 10A 10A 10A 10A 15A 15A 10A 15A 15A 10A 20A 15A 10A 40A 30A 30A DC Output Circuit Breaker: 15A 15A 15A 30A 30A 30A 40A 40A 40A 40A 40A 40A 60A 60A 60A 90A 90A 90A Cabinet Style: S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S3 S3 S3 Shipping Weight (lb): AC Input Amperes (Nominal): 7A 5A 5A 14A 10A 10A 23A 14A 15A 23A 14A 15A 28A 17A 20A 54A 27A 27A AC Input Circuit Breaker: 10A 10A 10A 20A 10A 10A 30A 20A 15A 30A 20A 15A 30A 25A 20A 70A 40A 40A DC Output Circuit Breaker: 15A 15A 15A 30A 30A 30A 50A 40A 50A 50A 50A 50A 60A 60A 60A 90A 90A 90A Cabinet Style: S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S3 S3 S3 Shipping Weight (lb): AC Input Amperes (Nominal): 14A 11A 8A 27A 17A 15A 45A 26A 22A 45A 24A 22A 56A 32A 27A n/a 68A 50A AC Input Circuit Breaker: 20A 15A 15A 40A 30A 25A 60A 40A 30A 60A 40A 30A 70A 60A 40A n/a 90A 70A DC Output Circuit Breaker: 15A 15A 15A 25A 25A 25A 40A 40A 40A 40A 40A 40A 60A 60A 60A n/a 90A 90A Cabinet Style: S1 S1 S1 S1 S1 S1 S2 S2 S2 S2 S2 S2 S2 S2 S2 n/a S3 S3 Shipping Weight (lb): n/a ST A B C D E F G H I J K If a space has no option selected a zero must be inserted. 17 Chargers Box ST Description A 1 1 Phase B C D E 0 1 F 0 1 Nominal DC Output Voltage 24Vdc 48Vdc 130Vdc Nominal DC Output Current 6ADC 12ADC 18ADC 20ADC 25ADC* 50ADC* Input Voltage (not UL listed) 240 Filtering Unfiltered Filtered / Eliminator Relays No Relays Individual Alarm Relay Contact Board Note: Charger with 208Vac input does not yet have UL/CSA approval. Box ST Description G H 0 1 I J K Remote sensing Not supplied Remote control panel Remote temperature compensation Remote DC voltage sensing Lines 1 and 2 Lines 1 and 3 Lines 2 and 3 Lines 1, 2 and 3 Lightning arrestor Not supplied Included Charging Not supplied Parallel charging Series charging Special treatments Nothing Fungus proofing Conformal seal on electronic DC board Option 1 and 2 Other options Nothing Lockable enclosure door 19" Rack 6" from front 23" Rack 6" from front Lines 1 and 4 Lines 1 and 5

20 Cordex 3.3kW System 125V Switch Mode Charger > 26.4A system capacity > Cordex 125V to 1.1kW modular rectifiers > AC input 208 to 240Vac > DC output 90 to 160Vdc > Front accessible for rack or wall mounting > Ethernet and SNMP communications 18 Chargers Cordex - Intergrated System Specifications Electrical Input Voltage: Phase: 1 or 3 Frequency: 208 to 240Vac 45 to 66Hz Current: System 125Vdc (max. 33A) Power Factor: Efficiency: Output Voltage: Current: >0.99 (input current) >93% (50 to 100% load) 90 to 160Vdc Load Regulation: Static <+0.5% Line Regulation: Static <+0.1% Transient Response: Wide Band Noise: Insulation: Mechanical Charger Enclosure: Dimensions L x W x H (in/mm): 8.8A per 125Vdc, up to 3 modules per shelf <+2% for 10 to 100% load step. 10min recovery time. <10mvrms <80mV pk to pk 2.5kVac Input-Earth, 3kVac Input-Output, 2kVac Output-Earth, 0.5kVac Signals-Earth Wall or rack mount 11.9 x 17.1 x 12.2 / 302 x 434 x 309 Weight (lb/kg): / Enclosure: NEMA 1 (charcoal finish) User Interface Features GUI: Display: Controls: LED Indicators: Audio: Language: Communication Ports RS-232 (DB-9): CAN OUT (RJ-12 offset): RS-485 (RJ-12 offset): Ethernet (RJ-45): Use Internet Explorer browser to access embedded GUI through Ethernet port or RS-232 craft port Full graphic LCD, 160 x 160 pixels, with backlight and contrast adjustment LCD touch screen with virtual alphanumeric keyboards System OK Green, Minor alarm Yellow, Major alarm Red Built in speaker for alarms and popup messages Multi language support including Chinese characters Craft port on front panel for local PC connection CAN communication BUSS to optional smart peripheral modules For future service options 10/100 Base T with half/full duplex Alarms Output: Input: GFD: SNMP: Data Logging Daily Statistics: Event Log: Battery Log: Control Functions: DC Output Panel: AC Input: Single Phase Three Phase Environmental Operating Temperature: Extended Temperature Humidity: Cooling: Heat Dissipation: Standards Safety: EMC: 6 potential free form C contacts 4 digital inputs * Rectifier module not included in system weight ** Not a service entrance Ground fault detect SNMP agent provides real-time system status to the network management software Minimum, maximum and average on input channels, with date and time stamp battery current, rectifier current, and AC mains voltage for last 90 days On all events such as alarms, power on, any change of state of the digital inputs, or other miscellaneous events Battery health history on last 20 discharges, time of discharge, and battery capacity Automatic, scheduled (periodic) or manual equalize Automatically terminated equalize charge Battery current terminate equalize Dynamic charge current control Battery capacity and runtime prediction Auto or manual battery test 2 x 2 Pole, 32A breakers (10KAIC) with alarm monitoring 1 x 2-pole 10KAIC (30KAIC option) 1 x 3-pole delta connection 10KAIC 1 x 3-pole wye connection 10KAIC -40 to 50 C / -40 to 122 F Rectifier derated to 65 C / 149 F 0 to 95% non-condensing Natural convection <900BTU per hour/system UL rd editions, CSA C22.2,No rd edition, EN 60950, CE ICES-003 Class A, FCC Part 15, Class A, FCC Part 68, EN Class AA (CISPR 22), EN ESD, EN Radiated Immunity, EN EFRT/Burst, EN Conducted Immunity

21 P45 Battery Charger Automatic Battery Charger > Microprocessor control > Provides regulated DC output and current limiting capabilities > Graphical interface > Wide temperature range: 0 to 50 C / 32 to 122 F > Approved for UL, CE, CSA and EMC standards P45 Series Single-Phase Charger Model: Input Output Voltage (Vac) Frequency (Hz) Voltage (Vdc) Current (A) P45X1012YYYZZZWWWW 120 to to to 999 P45X1024YYYZZZWWWW 120 to to to 999 P45X1036YYYZZZWWWW 120 to to to 999 P45X1048YYYZZZWWWW 120 to to to 999 P45X1072YYYZZZWWWW 120 to to to 999 P45X1125YYYZZZWWWW 120 to to to 999 P45X1144YYYZZZWWWW 120 to to to 999 P45X1240YYYZZZWWWW 120 to to to 999 Note: X: AC output ripple filtering levels as per NEMA PE5: 30mV/100mV/1% and 2% + customized. YYY: Charger Output Current (005 to 999) ZZZ: Input Voltage - Single Phase (120/208/220/230/240/380/400/415/480/600) Input Voltage - Three Phase (208/380/400/415/480/600) WWWW: Charger Optional Feature Codes Standard Features Metering and Timing: 0.5% accuracy DC voltage and current metering Remaining and elapsed equalize time Control Modes: Manual float/equalize toggle Control Adjustments: Float and equalize voltage Current limit Equalize period 0 to100 hours Float period 0 to100 days Equalize mode termination based on voltage, time and/or low DC volts event(s) Indicating LEDs: AC On green LED Common alarm flashing red LED Alarm Menu Indications: Charger failure based on low volts and low output DC current High DC volts Low DC volts Positive ground fault Negative ground fault AC fail Alarm Menu Functions (password protected): Adjustable alarm time delay Indications latch Alarm relays latch Alarm acknowledgment Alarm levels adjustment LED, LCD and relay test Remote indications: All alarms are wired to a common voltage free N.O. and N.C. dry contacts P45 Series Three-Phase Charger Model: Input Output Voltage (Vac) Frequency (Hz) Voltage (Vdc) Current (A) P45X3012YYYZZZWWWW 208 to to to 999 P45X3024YYYZZZWWWW 208 to to to 999 P45X3036YYYZZZWWWW 208 to to to 999 P45X3048YYYZZZWWWW 208 to to to 999 P45X3072YYYZZZWWWW 208 to to to 999 P45X3125YYYZZZWWWW 208 to to to 999 P45X3144YYYZZZWWWW 208 to to to 999 P45X3240YYYZZZWWWW 208 to to to 999 P45X3380YYYZZZWWWW 208 to to to 999 P45X3480YYYZZZWWWW 208 to to to 999 P45X3600YYYZZZWWWW 208 to to to 999 Optional Features Individual alarms form C contacts RS 232/485 communication ports Modbus on serial ports SNMP interface DC circuit breaker Negative temperature compensation 0.2%/ C Battery circuit breaker Distribution panel High capacity interrupting current CBs High temperature alarm and shut-down High volts shutdown via AC breaker trip AC input volts, amps and frequency readings High and low AC input voltage alarm High ripple alarm Power factor correction to 0.95 lagging Tropicalization Remote voltage sensing terminals Remote shutdown and equalize control Audible alarm Manual voltage control Input harmonic filter to comply with CE 50Hz or 400Hz input frequency Low DC volts load disconnect (load shedding) End of discharge alarm Negative slope for equal load sharing Battery discharging alarm Battery high temperature alarm and shutdown Battery ammeter and voltmeter Ampere-hour meter reading battery capacity % or AH DC distribution panel Oversized cabinets to fit batteries in separate compartments Special paint and NEMA / IP protection Seismic design Fungus proofing and tropicalization Special wiring 19 Chargers

22

23 Nickel Cadmium Batteries Available as pocket plate vented or low-maintenance design in robust clear or translucent case, nickel cadmium batteries offer a versatile and reliable power source in the most extreme conditions. > Clear Case Features High performance pocket plate type alkaline storage battery 25-year, field-proven design Easily visible electrolyte level and plate condition Strong impact-resistant clear case protects against shocks and vibrations Wide operating temperature range from 25 to 50 C / 13 to 122 F 5-year full warranty plus 15-year pro-rated > Translucent Case Features High performance nickel cadmium storage battery 20-year design life 5-year full warranty plus 15-year pro-rated > Lomain Features Excellent resistance against electrical and mechanical stress No risk of terminal decomposition or sudden failure due to plate construction 21 Extremely long watering cycles 20-year design life in stationary cycling operations 5-year full warranty plus 15-year pro-rated NiCad Batteries

24 NiCad Clear Case Nickel Cadmium Alkaline Battery > High performance alkaline storage battery > Cells do not emit any corrosive fumes and can be placed near delicate electrical equipment > Strong impact-resistant container protects against shocks and vibrations NiCad Clear Case Nickel Cadmium Clear Case Battery Feature Summary HDV very high rate HDH high rate HDM medium rate HDS long rate Standard Warranty: 5yr full plus 15yr prorated 5yr full plus 15yr prorated 5yr full plus 15yr prorated 5yr full plus 15yr prorated Service Life: 20yr 20yr 20yr 20yr Range of Capacity: 10 to 450AH 10 to 700AH 10 to 1000AH 10 to 1000AH Time of Discharge: 1 sec to 1 hr 1 sec to 10 hrs 1 sec to 10 hrs 1 sec to 10 hrs Operating Temperature: -40 to 55 C / -40 to 131 F -40 to 55 C / -40 to 131 F -40 to 55 C / -40 to 131 F -40 to 55 C / -40 to 131 F Terminal Type: Threaded nickel plated post Threaded nickel plated post Threaded nickel plated post Threaded nickel plated post 22 NiCad Batteries HDV Mechanical Specifications Cell Type Vented Dimensions- L x W x H (in/mm) Weight (lb/kg) Electrolyte (lb/kg) HDV 10P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.7 HDV 20P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.7 HDV 30P: 3 x 5.6 x 11.1 / 76 x 143 x / / 1.3 HDV 40P: 3 x 5.6 x 11.1 / 76 x 143 x / / 1 HDV 50P: 3.9 x 5.7 x 11.1 / 100 x 145 x / / 1.4 HDV 60P: 3.9 x 5.7 x 11.1 / 100 x 145 x / / 1.2 HDV 80P: 6.7 x 4.7 x 14.6 / 170 x 120 x / / 2.8 HDV 100P: 6.7 x 4.7 x 14.6 / 170 x 120 x / / 2.4 HDV 120P: 6.7 x 7.7 x 14.6 / 170 x 195 x / / 5.3 HDV 150P: 6.7 x 7.7 x 14.6 / 170 x 195 x / / 4.6 HDV 200P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 7.6 HDV 250P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 6.4 HDV 300P: 6.7 x 15.4 x 14.6 / 170 x 390 x / / 9.4 HDV 350P: 6.7 x 15.4 x 14.6 / 170 x 390 x / / 8.6 HDV 400P: 6.7 x 20.3 x 14.6 / 170 x 515 x / / 13 HDV 450P: 6.7 x 20.3 x 14.6 / 170 x 515 x / / 12 HDV Discharge Current To Final Voltage 0.85V/Cell at 25 C / 77 F Type C5 Seconds Minutes (AH 1.1V) HDV 10P: HDV 20P: HDV 30P: HDV 40P: HDV 50P: HDV 60P: HDV 80P: HDV 100P: HDV 120P: HDV 150P: HDV 200P: HDV 250P: HDV 300P: HDV 350P: HDV 400P: HDV 450P:

25 NiCad Clear Case Nickel Cadmium Alkaline Battery > Wide operating temperature range from -40 to 55 C / -40 to 131 F > 20-year proven design life > 5-year full plus 15-year pro-rated Nickel Cadmium Clear Case Battery HDH Mechanical Specifications Cell Type Vented Dimensions- L x W x H (in/mm) Weight (lb/kg) Electrolyte (lb/kg) HDH 10P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.9 HDH 20P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.9 HDH 30P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.7 HDH 40P: 3 x 5.6 x 10.5 / 76 x 143 x / / 1.2 HDH 50P: 3 x 5.6 x 10.5 / 76 x 143 x / / 1.1 HDH 60P: 3.9 x 5.7 x 10.9 / 100 x 145 x / / 1.6 HDH 80P: 3.9 x 5.7 x 10.9 / 100 x 145 x / / 1.3 HDH 100P: 4.7 x 6.7 x 14.6 / 120 x 170 x / / 3.2 HDH 120P: 4.7 x 6.7 x 14.6 / 120 x 170 x / / 2.9 HDH 150P: 4.7 x 6.7 x 14.6 / 120 x 170 x / / 2.6 HDH 200P: 6.7 x 7.7 x 14.6 / 170 x 195 x / / 5.2 HDH 250P: 6.7 x 7.7 x 14.6 / 170 x 195 x / / 4.4 HDH 300P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 7.8 HDH 350P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 7.2 HDH 400P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 6.7 HDH 450P: 6.7 x 15.4 x 14.6 / 170 x 390 x / / 10 HDH 500P: 6.7 x 15.4 x 14.6 / 170 x 390 x / / 9.5 HDH 600P: 6.7 x 20.3 x 14.6 / 170 x 515 x / / 13 HDH 700P: 6.7 x 20.3 x 14.6 / 170 x 515 x / / 12 HDH Discharge Current To Final Voltage 1V/Cell at 25 C / 77 F C5 (AH Seconds Minutes Type 1.10V) HDH 10P: HDH 20P: HDH 30P: HDH 40P: HDH 50P: HDH 60P: HDH 80P: HDH 100P: HDH 120P: HDH 150P: HDH 200P: HDH 250P: HDH 300P: HDH 350P: HDH 400P: HDH 450P: HDH 500P: HDH 600P: HDH 700P: * Performance tables to other end voltages available upon request 23 NiCad Batteries

26 NiCad Clear Case Nickel Cadmium Alkaline Battery 24 NiCad Batteries Nickel Cadmium Clear Case Battery HDM Mechanical Specifications Cell Type Vented Dimensions- L x W x H (in/mm) Weight (lb/kg) Electrolyte (lb/kg) HDM 10P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.9 HDM 20P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.9 HDM 30P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.8 HDM 40P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.7 HDM 50P: 3 x 5.6 x 10.5 / 76 x 143 x / / 1.2 HDM 60P: 3 x 5.6 x 10.5 / 76 x 143 x / / 1.1 HDM 80P: 3.9 x 5.7 x 10.6 / 100 x 145 x / / 1.6 HDM 100P: 4.7 x 6.7 x 14.6 / 120 x 170 x / / 3.4 HDM 120P: 4.7 x 6.7 x 14.6 / 120 x 170 x / / 3.3 HDM 150P: 4.7 x 6.7 x 14.6 / 120 x 170 x / / 3 HDM 200P: 6.7 x 7.7 x 14.6 / 170 x 195 x / / 5.7 HDM 250P: 6.7 x 7.7 x 14.6 / 170 x 195 x / / 5.2 HDM 300P: 6.7 x 7.7 x 14.6 / 170 x 195 x / / 4.7 HDM 350P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 8.5 HDM 400P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 8 HDM 450P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 7.5 HDM 500P: 6.7 x 15.4 x 14.6 / 170 x 390 x / / 11 HDM 600P: 6.7 x 15.4 x 14.6 / 170 x 390 x / / 10 HDM 700P: 6.7 x 20.3 x 14.6 / 170 x 515 x / / 15 HDM 800P: 6.7 x 20.3 x 14.6 / 170 x 515 x / / 14 HDM 900P: 6.7 x 20.3 x 14.6 / 170 x 515 x / / 13 HDM 1000P: 6.7 x 20.3 x 14.6 / 170 x 515 x / / 12 HDM Discharge Current To Final Voltage 1V/Cell at 25 C / 77 F Type C5 (AH 1.10V) 1 min 30 min 1 hr 1.5 hr 3 hr 5 hr HDM 10P: HDM 20P: HDM 30P: HDM 40P: HDM 50P: HDM 60P: HDM 80P: HDM 100P: HDM 120P: HDM 150P: HDM 200P: HDM 250P: HDM 300P: HDM 350P: HDM 400P: HDM 450P: HDM 500P: HDM 600P: Nickel Cadmium Clear Case Battery HDS Mechanical Specifications Cell Type Vented Dimensions- L x W x H (in/mm) Weight (lb/kg) Electrolyte (lb/kg) HDS 10P: 1.9 x 3 x 10.5 / 48.5 x 76.5 x / / 0.3 HDS 20P: 1.9 x 3 x 10.5 / 48.5 x 76.5 x / / 0.3 HDS 30P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.9 HDS 40P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.8 HDS 50P: 2 x 5.6 x 10.7 / 52 x 143 x / / 0.7 HDS 60P: 3 x 5.6 x 10.4 / 76 x 143 x / / 1.2 HDS 80P: 3 x 5.6 x 10.4 / 76 x 143 x / / 1.1 HDS 100P: 3.9 x 5.6 x 10.6 / 100 x 145 x / / 1.5 HDS 120P: 4.7 x 5.7 x 14.6 / 120 x 170 x / / 3.4 HDS 150P: 4.7 x 5.7 x 14.6 / 120 x 170 x / / 3.2 HDS 200P: 4.7 x 5.7 x 14.6 / 120 x 170 x / / 2.8 HDS 250P: 6.7 x 7.6 x 14.6 / 170 x 195 x / / 5.4 HDS 300P: 6.7 x 7.6 x 14.6 / 170 x 195 x / / 5 HDS 350P: 6.7 x 7.6 x 14.6 / 170 x 195 x / / 4.6 HDS 400P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 8.2 HDS 450P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 7.8 HDS 500P: 6.7 x 11.2 x 14.6 / 170 x 285 x / / 7 HDS 600P: 6.7 x 15.3 x 14.6 / 170 x 390 x / / 10.3 HDS 700P: 6.7 x 15.3 x 14.6 / 170 x 390 x / / 9.5 HDS 800P: 6.7 x 15.3 x 14.6 / 170 x 390 x / / 8.7 HDS 900P: 6.7 x 20.2 x 14.6 / 170 x 515 x / / 13 HDS 1000P: 6.7 x 20.2 x 14.6 / 170 x 515 x / / 12 HDS Discharge Current To Final Voltage 1V/Cell at 25 C / 77 F Type C5 (AH 1.10V) 30 min 1 hr 3 hr 5 hr 8 hr 10 hr HDS 10P: HDS 20P: HDS 30P: HDS 40P: HDS 50P: HDS 60P: HDS 80P: HDS 100P: HDS 120P: HDS 150P: HDS 200P: HDS 250P: HDS 300P: HDS 350P: HDS 400P: HDS 450P: HDS 500P: HDS 600P: HDS 700P: HDS 800P: HDS 900P: HDS 1000P: * Performance tables to other end voltages available upon request

27 NiCad Translucent Case Vented Nickel Cadmium Alkaline Battery > Three battery ranges designed for different discharge ranges: KH/P Range (High) 1 sec to 90 min KM/P Range (Medium) 5 min to 5 hrs KL/P Range (Long) 1 to 10 hrs Vented Nickel Cadmium Translucent Case Battery General Specifications Models: KH/P high rate KM/P medium rate KL/P rate Standard Warranty: 5 yr full plus 15 yr prorated 5 yr full plus 15 yr prorated 5 yr full plus 15 yr prorated Service Life: 20 yr 20 yr 20 yr Range of Capacity: 10 to 800AH 11 to 1250AH 11 to 1500AH Time of Discharge: 1sec to 90min 5min to 5hrs 1 to 10hrs Operating Temperature: -40 to 55 C / -40 to 131 F -40 to 55 C / -40 to 131 F -40 to 55 C / -40 to 131 F Terminal Type: Threaded nickel plated post Threaded nickel plated post Threaded nickel plated post KH Mechanical Specifications Type Nominal Capacity (AH) Dimensions- L x W x H (in/mm) Terminal (Nut, Screw) Terminal Size Total Weight (lb/kg) KH 10P: x 3.3 x 10.1 / 46 x 85 x 257 N 2 x M / 1.6 KH 20P: x 3.3 x 10.1 / 46 x 85 x 257 N 2 x M / 1.9 KH 30P: x 5.3 x 14.2 / 53 x 134 x 360 S 2 x M 8 9 / 4.1 KH 40P: x 5.3 x 14.2 / 53 x 134 x 360 S 2 x M / 4.4 KH 50P: x 5.3 x 14.2 / 53 x 134 x 360 S 2 x M 8 10 / 4.6 KH 65P: x 5.3 x 14.2 / 69 x 134 x 360 S 2 x M / 6.1 KH 80P: x 5.3 x 14.2 / 69 x 134 x 360 S 2 x M / 6.6 KH 100P: x 5.3 x 14.2 / 104 x 134 x 360 S 2 x M / 8.8 KH 125P: x 5.3 x 14.2 / 104 x 134 x 360 S 2 x M / 9.7 KH 150P: x 6.5 x 14.2 / 108 x 164 x 360 S 4 x M / 11.9 KH 185P: x 6.5 x 14.2 / 164 x 158 x 360 S 4 x M / 15.6 KH 200P: x 6.5 x 14.2 / 164 x 158 x 360 S 4 x M 8 35 / 16.2 KH 235P: x 6.5 x 14.2 / 164 x 158 x 360 S 4 x M / 17.1 KH 250P: x 6.5 x 14.2 / 164 x 158 x 360 S 4 x M / 17.4 KH 280P: x 9.7 x 14.2 / 176 x 246 x 360 S 4 x M / 23.7 KH 300P: x 9.7 x 14.2 / 176 x 246 x 360 S 4 x M / 24.2 KH 320P: x 9.7 x 14.2 / 176 x 246 x 360 S 4 x M / 24.6 KH 360P: x 14.5 x 14.2 / 176 x 368 x 360 S 6 x M / 33.9 KH 390P: x 14.5 x 14.2 / 176 x 368 x 360 S 6 x M / 34.7 KH 420P: x 14.5 x 14.2 / 176 x 368 x 360 S 6 x M / 35.4 KH 450P: x 14.5 x 14.2 / 176 x 368 x 360 S 6 x M / 36.3 KH 480P: x 14.5 x 14.2 / 176 x 368 x 360 S 6 x M / 37 KH 520P: x 17.6 x 14.2 / 176 x 448 x 360 S 8 x M / 44.7 KH 560P: x 17.6 x 14.2 / 176 x 448 x 360 S 8 x M / 45.9 KH 600P: x 17.6 x 14.2 / 176 x 448 x 360 S 8 x M / 47 KH 640P: x 17.6 x 14.2 / 176 x 448 x 360 S 8 x M / 48.1 KH 700P: x 22 x 14.2 / 176 x 558 x 360 S 10 x M / 57.2 KH 750P: x 22 x 14.2 / 176 x 558 x 360 S 10 x M / 58.6 KH 850P: x 22 x 14.2 / 176 x 558 x 360 S 10 x M / NiCad Batteries

28 NiCad Translucent Case Vented Nickel Cadmium Alkaline Battery > High-performance nickel cadmium storage battery > 20-year design life > 5-year full warranty plus 15-year pro-rated 26 NiCad Batteries Vented Nickel Cadmium Translucent Case Battery KH Discharge Current To Final Voltage 1V/Cell at 25 C / 77 F Type C5 (AH 1.10V) 1sec 5sec 10sec 30sec 1min 5min 10min 15min 30min 60min 90min KH 10P: KH 20P: KH 30P: KH 40P: KH 50P: KH 65P: KH 80P: KH 100P: KH 125P: KH 150P: KH 185P: KH 200P: KH 235P: KH 250P: KH 280P: KH 300P: KH 320P: KH 360P: KH 390P: KH 420P: KH 450P: KH 480P: KH 520P: KH 560P: KH 600P: KH 640P: KH 700P: KH 750P: KH 800P: * Performance tables to other end voltages available upon request

29 NiCad Translucent Case Vented Nickel Cadmium Alkaline Battery Nickel Cadmium Translucent Battery KM Mechanical Specifications Type Nominal Capacity (AH) Dimensions- L x W x H (in/mm) Terminal (Nut, Screw) Terminal Size Total Weight (lb/kg) Weight w/out electrolyte KM 11P/N: x 3.3 x 6.6 / 46 x 85 x 167 N 2 x M / / 0.71 KM 18P/N: x 3.3 x 9.3 / 46 x 85 x 237 N 2 x M / / 1.04 KM 24P/N: x 3.3 x 9.3 / 46 x 85 x 237 N 2 x M / / 1.12 KM 30P/N: x 3.3 x 9.3 / 46 x 85 x 237 N 2 x M / / 1.27 KM 40P/N: x 3.3 x 9.3 / 85 x 85 x 237 N 2 x M / / 1.8 KM 48P/N: x 3.3 x 9.3 / 85 x 85 x 237 N 2 x M / / 2.05 KM 55P/N: x 3.3 x 9.3 / 85 x 85 x 237 N 2 x M / / 2.3 KM 65P/N: 65 2 x 5.3 x 14.3 / 53 x 134 x 364 S 2 x M / / 3.56 KM 75P/N: 75 2 x 5.3 x 14.3 / 53 x 134 x 364 S 2 x M 8 11 / / 3.78 KM 90P/N: x 5.3 x 14.3 / 69 x 134 x 364 S 2 x M / / 4.36 KM 110P/N: x 5.3 x 14.3 / 69 x 134 x 364 S 2 x M / / 4.94 KM 125P/N: x 6.5 x 14.3 / 70 x 164 x 364 S 2 x M 8 17 / / 5.61 KM 140P/N: x 6.5 x 14.3 / 70 x 164 x 364 S 2 x M / / 6.04 KM 160P/N: x 6.5 x 14.3 / 108 x 164 x 364 S 2 x M / / 6.92 KM 185P/N: x 6.5 x 14.3 / 108 x 164 x 364 S 2 x M 8 24 / / 7.5 KM 205P/N: x 6.5 x 14.3 / 108 x 164 x 364 S 2 x M / / 8.27 KM 225P/N: x 6.5 x 14.3 / 108 x 164 x 364 S 2 x M / / 8.82 KM 250P/N: x 6.5 x 14.3 / 108 x 164 x 364 S 2 x M 8 27 / / 9.62 KM 270P/N: x 6.2 x 14.3 / 164 x 158 x 364 S 2 x M / / 11.2 KM 300P/N: x 6.2 x 14.3 / 164 x 158 x 364 S 2 x M / / 11.5 KM 320P/N: x 6.2 x 14.3 / 164 x 158 x 364 S 2 x M / / 12.2 KM 340P/N: x 6.2 x 14.3 / 164 x 158 x 364 S 2 x M / / 13 KM 355P/N: x 6.2 x 14.3 / 164 x 158 x 364 S 2 x M / / 13.7 KM 380P/N: x 6.2 x 14.3 / 164 x 158 x 364 S 2 x M / / 32 KM 400P/N: x 6.2 x 14.3 / 164 x 158 x 364 S 2 x M / / 15.1 KM 450P/N: x 9.7 x 15 / 176 x 246 x 382 S 4 x M / / 20 KM 500P/N: x 9.7 x 15 / 176 x 246 x 382 S 4 x M / / 21.2 KM 550P/N: x 9.7 x 15 / 176 x 246 x 382 S 4 x M / / 22.4 KM 600P/N: x 14.5 x 15 / 176 x 368 x 382 S 6 x M / / 27 KM 675P/N: x 14.5 x 15 / 176 x 368 x 382 S 6 x M / / 29.5 KM 750P/N: x 14.5 x 15 / 176 x 368 x 382 S 6 x M / / 32 KM 1000P/N: x 17.6 x 15 / 176 x 448 x 382 S 8 x M / / 42.8 KM 1250P/N: x 22 x 15 / 176 x 558 x 382 S 10 x M / / NiCad Batteries

30 NiCad Translucent Case Vented Nickel Cadmium Alkaline Battery 28 NiCad Batteries Nickel Cadmium Translucent Case Battery KM Discharge Current To Final Voltage 1.15V/Cell at 25 C / 77 F Type 5min 10min 15min 20min 30min 1hr 1.5hr 2hr 3hr 4hr 5hr KM 11P/N: KM 18P/N: KM 24P/N: KM 30P/N: KM 40P/N: KM 48P/N: KM 55P/N: KM 65P/N: KM 75P/N: KM 90P/N: KM 110P/N: KM 125P/N: KM 140P/N: KM 160P/N: KM 185P/N: KM 205P/N: KM 225P/N: KM 250P/N: KM 270P/N: KM 300P/N: KM 320P/N: KM 340P/N: KM 355P/N: KM 380P/N: KM 400P/N: KM 450P/N: KM 500P/N: KM 550P/N: KM 600P/N: KM 675P/N: KM 750P/N: KM 1000P/N: KM 1250P/N: * Performance tables to other end voltages available upon request Nickel Cadmium Translucent Case Battery KM Discharge Current To Final Voltage 1.10V/Cell at 25 C / 77 F Type 5min 10min 15min 20min 30min 1hr 1.5hr 2hr 3hr 4hr 5hr KM 11P/N: KM 18P/N: KM 24P/N: KM 30P/N: KM 40P/N: KM 48P/N: KM 55P/N: KM 65P/N: KM 75P/N: KM 90P/N: KM 110P/N: KM 125P/N: KM 140P/N: KM 160P/N: KM 185P/N: KM 205P/N: KM 225P/N: KM 250P/N: KM 270P/N: KM 300P/N: KM 320P/N: KM 340P/N: KM 355P/N: KM 380P/N: KM 400P/N: KM 450P/N: KM 500P/N: KM 550P/N: KM 600P/N: KM 675P/N: KM 750P/N: KM 1000P/N: KM 1250P/N:

31 NiCad Translucent Case Vented Nickel Cadmium Alkaline Battery Nickel Cadmium Translucent Case Battery KM Discharge Current To Final voltage 1.05V/Cell at 25 C / 77 F Type 5min 10min 15min 20min 30min 1hr 1.5hr 2hr 3hr 4hr 5hr KM 11P/N: KM 18P/N: KM 24P/N: KM 30P/N: KM 40P/N: KM 48P/N: KM 55P/N: KM 65P/N: KM 75P/N: KM 90P/N: KM 110P/N: KM 125P/N: KM 140P/N: KM 160P/N: KM 185P/N: KM 205P/N: KM 225P/N: KM 250P/N: KM 270P/N: KM 300P/N: KM 320P/N: KM 340P/N: KM 355P/N: KM 380P/N: KM 400P/N: KM 450P/N: KM 500P/N: KM 550P/N: KM 600P/N: KM 675P/N: KM 750P/N: KM 1000P/N: KM 1250P/N: Nickel Cadmium Translucent Case Battery KM Discharge Current To Final voltage 1V/Cell at 25 C / 77 F Type 5min 10min 15min 20min 30min 1hr 1.5hr 2hr 3hr 4hr 5hr KM 11P/N: KM 18P/N: KM 24P/N: KM 30P/N: KM 40P/N: KM 48P/N: KM 55P/N: KM 65P/N: KM 75P/N: KM 90P/N: KM 110P/N: KM 125P/N: KM 140P/N: KM 160P/N: KM 185P/N: KM 205P/N: KM 225P/N: KM 250P/N: KM 270P/N: KM 300P/N: KM 320P/N: KM 340P/N: KM 355P/N: KM 380P/N: KM 400P/N: KM 450P/N: KM 500P/N: KM 550P/N: KM 600P/N: KM 675P/N: KM 750P/N: KM 1000P/N: KM 1250P/N: NiCad Batteries

32 NiCad Translucent Case Vented Nickel Cadmium Alkaline Battery 30 NiCad Batteries Vented Nickel Cadmium Translucent Case Battery KL Mechanical Specifications Type Rated Capacity (AH) Dimension- L x W x H (in/mm) Terminal (Nut, Screw) Terminal Size Weight (lb/kg) KL 11P: x 3.3 x 10.1 / 46 x 85 x 257 N 2 x M / 1.3 KL 18P: x 3.3 x 10.1 / 46 x 85 x 257 N 2 x M / 1.4 KL 24P: x 3.3 x 10.1 / 46 x 85 x 257 N 2 x M / 1.5 KL 30P: x 3.3 x 10.1 / 46 x 85 x 257 N 2 x M / 1.64 KL 40P: x 3.3 x 10.1 / 85 x 85 x 257 N 2 x M 10 6 / 2.7 KL 45P: x 3.3 x 10.1 / 85 x 85 x 257 N 2 x M / 2.8 KL 55P: x 3.3 x 10.1 / 85 x 85 x 257 N 2 x M / 2.8 KL 65P: x 3.3 x 10.1 / 85 x 85 x 257 N 2 x M / 3 KL 80P: x 5.3 x 15.5 / 69 x 134 x 394 N 2 x M / 5.3 KL 100P: x 5.3 x 15.5 / 69 x 134 x 394 N 2 x M / 5.6 KL 120P: x 5.3 x 15.5 / 69 x 134 x 394 N 2 x M / 5.7 KL 140P: x 5.3 x 15.5 / 69 x 134 x 394 N 2 x M / 6.1 KL 150P: x 6.5 x 15.5 / 70 x 164 x 394 N 2 x M / 7.1 KL 160P: x 6.5 x 15.5 / 108 x 164 x 394 N 2 x M / 9.8 KL 185P: x 6.5 x 15.5 / 108 x 164 x 394 N 2 x M / 10 KL 200P: x 6.5 x 15.5 / 108 x 164 x 394 N 2 x M / 10.4 KL 230P: x 6.5 x 15.5 / 108 x 164 x 394 N 2 x M / 10.8 KL 270P: x 6.5 x 15.5 / 108 x 164 x 394 N 2 x M / 11.3 KL 300P: x 6.5 x 15.5 / 108 x 164 x 394 N 2 x M / 11.7 KL 340P: x 6.5 x 15.4 / 158 x 164 x 392 S 2 x M / 16.6 KL 370P: x 6.5 x 15.4 / 158 x 164 x 392 S 2 x M / 17.1 KL 400P: x 6.5 x 15.4 / 158 x 164 x 392 S 2 x M / 17.7 KL 435P: x 6.5 x 15.4 / 158 x 164 x 392 S 2 x M / 18.2 KL 470P: x 6.5 x 15.4 / 158 x 164 x 392 S 2 x M / 18.8 KL 520P: x 9.7 x 16.1 / 176 x 246 x 408 S 4 x M / 26.7 KL 560P: x 9.7 x 16.1 / 176 x 246 x 408 S 4 x M / 27.2 KL 625P: x 9.7 x 16.1 / 176 x 246 x 408 S 4 x M / 28.3 KL 650P: x 14.5 x 16.1 / 176 x 368 x 408 S 6 x M / 37 KL 740P: x 14.5 x 16.1 / 176 x 368 x 408 S 6 x M / 38.6 KL 840P: x 14.5 x 16.1 / 176 x 368 x 408 S 6 x M / 40.6 KL 1000P: x 17.6 x 16.1 / 176 x 448 x 408 S 8 x M / 52.5 KL 1250P: x 22 x 16.1 / 176 x 558 x 408 S 8 x M / 62 KL 1500P: x 22 x 16.1 / 176 x 558 x 408 S 8 x M / 66.4 KL Discharge Current To Final Voltage 1V/Cell at 25 C / 77 F Type C5 (AH 1.10V) 1 hr 3 hr 5 hr 8 hr 10 hr KL 11P: KL 18P: KL 24P: KL 30P: KL 40P: KL 45P: KL 55P: KL 65P: KL 80P: KL 100P: KL 120P: KL 140P: KL 150P: KL 160P: KL 185P: KL 200P: KL 230P: Type C5 (AH 1.10V) 1 hr 3 hr 5 hr 8 hr 10 hr KL 270P: KL 315P: KL 340P: KL 370P: KL 400P: KL 435P: KL 470P: KL 520P: KL 560P: KL 600P: KL 650P: KL 740P: KL 840P: KL 1000P: KL 1250P: KL 1500P: * Performance tables to other end voltages available upon request

33 NiCad Range Lomain Extreme Low Maintenance > Nickel cadmium storage battery > Exceptionally long lifetime minimizes maintenance > 20-year design life Nickel Cadmium Range Lomain General Specifications Model: KGL KGM Standard Warranty: 5yr full plus 15yr prorated 5yr full plus 15yr prorated Service Life: 20yr 20yr Range of Capacity: 12 to 1390AH 11 to 1250AH Recommended Discharge Time: 1 to 100 hrs 30 to 120 min Operating Temperature: -30 to 45 C / -22 to 113 F -30 to 45 C / -22 to 113 F Terminal Type: Threaded nickel plated post Threaded nickel plated post Float Charge 1.42V/cell 1.42V/cell Boot Charge 1.45V/cell 1.45V/cell Current Limitation 0.1 la 0.1 la KGM/P Mechanical Specifications Type Dimensions- L x W x H (in/mm) Weight (lb/kg) KGM 11P: 1.8 x 3.3 x 7.3 / 46 x / 1 KGM 18P: 1.8 x 3.3 x 9.5 / 46 x 85 x / 1.3 KGM 24P: 1.8 x 3.3 x 9.5 / 46 x 85 x / 1.6 KGM 30P: 1.8 x 3.3 x 9.5 / 46 x 85 x / 1.7 KGM 40P: 3.3 x 3.3 x 9.5 / 85 x 85 x / 2.8 KGM 48P: 3.3 x 3.3 x 9.5 / 85 x 85 x / 2.8 KGM 55P: 3.3 x 3.3 x 9.5 / 85 x 85 x / 3 KGM 65P: 2.1 x 5.3 x 15.4 / 53 x 134 x / 4.9 KGM 75P: 2.1 x 5.3 x 15.4 / 53 x 134 x / 5 KGM 90P: 2.7 x 5.3 x 15.4 / 69 x 134 x / 6.2 KGM 110P: 2.7 x 5.3 x 15.4 / 69 x 134 x / 6.5 KGM 125P: 2.8 x 6.5 x 15.4 / 70 x 164 x / 7.7 KGM 140P: 2.8 x 6.5 x 15.4 / 70 x 164 x / 7.8 KGM 160P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 10.6 KGM 185P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 10.9 KGM 205P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 11.2 KGM 225P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 11.6 KGM 250P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 12.2 KGM 270P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 16.3 KGM 300P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 16.5 KGM 320P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 17 KGM 340P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 17.5 KGM 355P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 18 KGM 380P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 18.5 KGM 400P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 18.9 KGM 450P: 6.9 x 9.7 x 16.1 / 176 x 246 x / 27.3 KGM 500P: 6.9 x 9.7 x 16.1 / 176 x 246 x / 28.3 KGM 550P: 6.9 x 9.7 x 16.1 / 176 x 246 x / 29.3 KGM 600P: 6.9 x 14.5 x 16.1 / 176 x 368 x / 40.7 KGM 675P: 6.9 x 14.5 x 16.1 / 176 x 368 x / 41.9 KGM 750P: 6.9 x 14.5 x 16.1 / 176 x 368 x / 43.1 KGM 1000P: 6.9 x 17.6 x 16.1 / 176 x 448 x / 56 KGM 1250P: 6.9 x 17.6 x 16.1 / 176 x 448 x / 68.9 KGL/P Mechanical Specifications Type Dimensions- L x W x H (in/mm) Weight (lb/kg) KGL 12P: 1.8 x 3.3 x 7.3 / 46 x / 1 KGL 20P: 1.8 x 3.3 x 9.5 / 46 x 85 x / 1.5 KGL 25P: 1.8 x 3.3 x 9.5 / 46 x 85 x / 1.5 KGL 35P: 1.8 x 3.3 x 9.5 / 46 x 85 x / 1.6 KGL 45P: 3.3 x 3.3 x 9.5 / 85 x 85 x / 2.7 KGL 50P: 3.3 x 3.3 x 9.5 / 85 x 85 x / 2.8 KGL 60P: 3.3 x 3.3 x 15.4 / 85 x 85 x / 3 KGL 70P: 2.1 x 5.3 x 15.4 / 53 x 134 x / 4.9 KGL 80P: 2.1 x 5.3 x 15.4 / 53 x 134 x / 5 KGL 100P: 2.7 x 5.3 x 15.4 / 69 x 134 x / 6.2 KGL 120P: 2.7 x 5.3 x 15.4 / 69 x 134 x / 6.5 KGL 135P: 2.8 x 6.5 x 15.4 / 70 x 164 x / 7.7 KGL 155P: 2.8 x 6.5 x 15.4 / 70 x 164 x / 7.8 KGL 175P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 10.6 KGL 205P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 10.9 KGL 225P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 11.2 KGL 245P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 11.6 KGL 275P: 4.3 x 6.5 x 15.4 / 108 x 164 x / 12.2 KGL 300P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 16.3 KGL 330P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 16.5 KGL 350P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 17 KGL 375P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 17.5 KGL 390P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 18 KGL 420P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 18.5 KGL 440P: 6.5 x 6.2 x 15.4 / 164 x 158 x / 18.9 KGL 500P: 6.9 x 9.7 x 16.1 / 176 x 246 x / 27.3 KGL 555P: 6.9 x 9.7 x 16.1 / 176 x 246 x / 28.3 KGL 610P: 6.9 x 9.7 x 16.1 / 176 x 246 x / 29.3 KGL 665P: 6.9 x 14.5 x 16.1 / 176 x 368 x / 40.7 KGL 750P: 6.9 x 14.5 x 16.1 / 176 x 368 x / 41.9 KGL 835P: 6.9 x 14.5 x 16.1 / 176 x 368 x / 43.1 KGL 1110P: 6.9 x 17.6 x 16.1 / 176 x 448 x / 56 KGL 1390P: 6.9 x 22 x 16.1 / 176 x 558 x / NiCad Batteries

34 NiCad Range Lomain Extreme Low Maintenance > Low pressure flame arresting vent > Pocket plate design > 5-year full warranty plus 15-year pro-rated 32 NiCad Batteries Nickel Cadmium Range Lomain KGL/P Discharge Current (A) to End Voltage 1VPC at 25 C / 77 F Fully Charged Type 5min 10min 20min 30min 1hr 1.5hr 2hr 3hr 4hr 5hr 6hr 7hr 8hr 9hr 10hr KGL 12P: KGL 20P: KGL 25P: KGL 35P: KGL 45P: KGL 50P: KGL 60P: KGL 70P: KGL 80P: KGL 100P: KGL 120P: KGL 135P: KGL 155P: KGL 175P: KGL 205P: KGL 225P: KGL 245P: KGL 275P: KGL 300P: KGL 330P: KGL 350P: KGL 375P: KGL 390P: KGL 420P: KGL 440P: KGL 500P: KGL 555P: KGL 610P: KGL 665P: KGL 750P: KGL 835P: KGL 1110P: KGL 1390P:

35 NiCad Range Lomain Extreme Low Maintenance > Two battery ranges designed for different discharge ranges: KGL/P: Low discharge rates over long periods of time KGM/P: Both high and low discharge rates for combination loads Nickel Cadmium Range Lomain KGM/P Discharge Current (A) to End Voltage 1VPC at 25 C / 77 F Fully Charged Type 5min 10min 20min 30min 1hr 1.5hr 2hr 3hr 5hr 6hr 7hr 8hr 9hr 10hr KGM 11P: KGM 18P: KGM 24P: KGM 30P: KGM 40P: KGM 48P: KGM 55P: KGM 65P: KGM 75P: KGM 90P: KGM 110P: KGM 125P: KGM 140P: KGM 160P: KGM 185P: KGM 205P: KGM 225P: KGM 250P: KGM 270P: KGM 300P: KGM 320P: KGM 340P: KGM 355P: KGM 380P: KGM 400P: KGM 450P: KGM 500P: KGM 550P: KGM 600P: KGM 675P: KGM 750P: KGM 1000P: KGM 1250P: NiCad Batteries

36

37 Flooded Lead Acid Batteries > Flooded Tubular OPzS Type OPzS Stationary Lead Acid Batteries are designed to provide battery power for deep cycling applications in the telecommunication, utility, communication and transportation industries. Due to the extremely low levels of selfdischarge, they are also suitable for photovoltaic applications. OPzS batteries have a proven long life, low water consumption and a low selfdischarge rate. A unique tubular positive plate design prevents potential escape of active materials during operation, and the containers are extremely resistant to chemical influences and mechanical damage. Manufactured in accordance with DIN and ISO standards. Detail of tubular positive plate > AlphaCell OGi The AlphaCell OGi battery is designed to provide battery power for critical applications. The flooded lead acid battery, with its low level of self-discharge, makes it ideal for back up power applications in the telecommunication, utility and transportation industries. The transparent, impact-resistant container allows the user to easily observe electrolyte levels, as the batteries require minimal topping throughout their lifecycle. The AlphaCell OGi batteries are approved to DIN 40737, IEC and VDE 0510 standards. > AlphaCell SMU-HR The AlphaCell SMU-HR, with Absorbed Glass Mat (AGM) technology, is a high discharge rate VRLA battery specifically designed for UPS, power generation and switchgear applications. Low calcium grid alloy reduces gassing to extend battery life. This high rate discharge cycle battery is available in 12V ranging from 9 to 150AH. > AlphaCell SMU-F The AlphaCell SMU-F battery has front access terminals and is specifically designed for telecommunications applications. With Absorbed Glass Mat (AGM) technology, the SMU-F is a highly reliable, versatile and cost effective VRLA battery. This high performance and long life battery is available in 12V ranging from 50 to 170AH. 35 Flooded Lead Acid Batteries > AlphaCell SMU-C The AlphaCell SMU-C range (deep cycle) is designed for superior performance of high power output and excellent deep cycle life for energy applications. > AlphaCell SMU-M Offered in a full range of 20-year design life flooded or valve regulated type, with capacities ranging from 20 to 3000AH.

38 AlphaCell OPzS Stationary Flooded Tubular Lead Acid Battery > Power range: 12V from 50 to 150AH 6V from 200 to 300AH 2V from 100 to 3000AH > Ideal for backup power, security systems, telecommunications and other deep cycle applications AlphaCell OPzS Models AlphaCell OPzS 2V AlphaCell OPzS 6V AlphaCell OPzS 12V 36 Standard Warranty: 5yr full plus 15yr prorated 5yr full plus 15yr prorated 5yr full plus 15yr prorated Service Life: >20yr >20yr >20yr Battery Type: Flooded lead acid Flooded lead acid Flooded lead acid Range of Capacity: 100 to 3000AH 200 to 300AH 50 to 150AH Time of Discharge: 10min to 8hrs 10min to 8hrs 10min to 8hrs Heat Resistant: Moderate Moderate Moderate Operating Temperature: -20 to 55 C / -4 to 131 F -20 to 55 C / -4 to 131 F -20 to 55 C / -4 to 131 F Terminal Type: Threaded copper insert Threaded copper insert Threaded copper insert Mechanical Amperes to Final Voltage of 1.75VPC at 20 C / 68 F Flooded Lead Acid Batteries Type Dimensions- L x W x H (in/mm) Weight w/acid (lb/kg) 1 OPzS 12 50: 10.5 x 8 x 15 / 272 x 205 x / 37 2 OPzS : 10.5 x 8 x 15 / 272 x 205 x / 53 3 OPzS : 15 x 8 x 15 / 380 x 205 x / 76 4 OPzS 6 200: 10.5 x 8 x 15 / 272 x 205 x / 48 5 OPzS 6 250: 15 x 8 x 15 / 380 x 205 x / 65 6 OPzS 6 300: 15 x 8 x 15 / 380 x 205 x / 73 2 OPzS 2 100: 4 x 8 x 14.5 / 103 x 206 x / 10 3 OPzS 2 150: 4 x 8 x 14.5 / 103 x 206 x / 16 4 OPzS 2 200: 4 x 8 x 14.5 / 103 x 206 x / 18 5 OPzS 2 250: 4.5 x 8 x 14.5 / 124 x 206 x / 22 6 OPzS 2 300: 5.5 x 8 x 14.5 / 145 x 206 x / 26 5 OPzS 2 350: 4.5 x 8 x 19 / 124 x 206 x / 29 6 OPzS 2 420: 5.5 x 8 x 19 / 145 x 206 x / 34 7 OPzS 2 490: 6.5 x 8 x 19 / 166 x 206 x / 39 6 OPzS 2 600: 5.5 x 8 x 26 / 145 x 206 x / 50 8 OPzS 2 800: 7.5 x 835 x 26 / 191 x 210 x / OPzS : 9 x 8.2 x 26 / 233 x 210 x / OPzS : 11 x 8.2 x 26 / 275 x 210 x / OPzS : 11 x 8.2 x 32 / 275 x 210 x / OPzS : 15.5 x 8.3 x 31 / 397 x 212 x / OPzS : 19 x 8.3 x 31 / 487 x 212 x / OPzS : 22.5 x 8.3 x 31 / 576 x 212 x / 240 Minutes Hours Type OPzS12 50: OPzS12 100: OPzS : OPzS 6 200: OPzS 6 250: OPzS 6 300: OPzS 2 100: OPzS 2 150: OPzS 2 200: OPzS 2 250: OPzS 2 300: OPzS 2 350: OPzS 2 420: OPzS 2 490: OPzS 2 600: OPzS 2 800: OPzS : OPzS : OPzS : OPzS : OPzS : OPzS : H H L W

39 AlphaCell OGi Stationary Flat Plate Flooded Lead Acid Battery > Power ranges from: 12V from 25 to 150AH 6V from 175 to 300AH 2V from 600 to 900AH > Wide operating temperature range from -20 to 55 C / -4 to 131 F > 20-year design life AlphaCell OGi 12, 6 and 2V Specifications Standard Warranty: Battery Type: Range of Capacity: 3yr full plus 17yr prorated Stationary flooded lead acid 25 to 900AH Recommended Float Voltage: 20 C / 68 F Operational Temperature: 25 C / 77 F Terminal Type: Positive Electrode: Negative Electrode: Threaded copper insert Round-grid plate with circular bars available with low antimony Flat plate with long life expander and available with low antimony Separation: Microporous separator Electrolyte: Specific gravity of 1.24 ±0.01kg/l at 20 C Container: High impact, transparent SAN Lid: SAN in dark grey color Mechanical Type 1 OGi 12 25: 2 OGi 12 50: 3 OGi 12 75: 4 OGi : 5 OGi : 6 OGi : 7 OGi 6 175: 8 OGi 6 200: 9 OGi 6 225: 10 OGi 6 250: 11 OGi 6 275: 12 OGi 6 300: 24 OGi 2 600: 30 OGi 2 750: 36 OGi 2 900: Dimensions - L x W x H (in/mm) 10.7 x 8.1 x 14.8 / 272 x 205 x x 8.1 x 14.8 / 272 x 205 x x 8.1 x 14.8 / 272 x 205 x x 8.1 x 14.8 / 272 x 205 x x 8.1 x 14.8 / 380 x 205 x x 8.1 x 14.8 / 380 x 205 x x 8.1 x 14.8 / 272 x 205 x x 8.1 x 14.8 / 272 x 205 x x 8.1 x 14.8 / 380 x 205 x x 8.1 x 14.8 / 380 x 205 x x 8.1 x 14.8 / 380 x 205 x x 8.1 x 14.8 / 380 x 205 x x 10.7 x 14.8 / 205 x 272 x x 15 x 14.8 / 205 x 380 x x 15 x 14.8 / 205 x 380 x 375 Wt. (lb/kg) Batt w/electrolyte 72.8 / / / / 10.9 Wt. (lb/kg) electrolyte only 108 / / / / / / / / / / / / / / / / / / / / / / / / / / 16 Amperes to Final Voltage of 1.75VPC at 20 C / 68 F Minutes Type OGi 12 25: OGi 12 50: OGi 12 75: OGi : OGi : OGi : OGi 6 175: OGi 6 200: OGi 6 225: OGi 6 250: OGi 6 275: OGi 6 300: OGi 2 600: OGi 2 750: OGi 2 900: Amperes to Final Voltage of 1.75VPC at 20 C / 68 F Hours Type OGi 12 25: OGi 12 50: OGi 12 75: OGi : OGi : OGi : OGi 6 175: OGi 6 200: OGi 6 225: OGi 6 250: OGi 6 275: OGi 6 300: OGi 2 600: OGi 2 750: OGi 2 900: Flooded Lead Acid Batteries

40 AlphaCell SMU-HR High Rate Discharge VRLA Battery > Power range available in 12V from 9 to 150AH > Optimized grid for high-power density > Upright, side or end mounting > Thermally-welded case eliminates leakage > Optional flame retardant ABS casing to UL94-VO > 10-year design life > 2-year full warranty 38 Valve-Regulated Batteries AlphaCell SMU-HR Specifications Standard Warranty: 2yr full plus 8yr pro-rated Battery Type: Valve regulated lead acid Range of Capacity: 9 to 150AH Recommended Float Voltage: 20 C / 68 F Operating Temperature: 25 C / 77 F Terminal Type: Threaded copper insert Optional: UL 94 VO flame retardant casing Mechanical Type Dimensions- L x W x H (in/mm) Weight (lb/kg) Stud Hole Size (mm) SMU-HR 12 9: 5.9 x 2.6 x 3.7 / 151 x 65 x / (snap on) SMU-HR 12 18: 7.1 x 3 x 6.6 / 181 x 77 x / (flag terminal) SMU-HR 12 35: 7.8 x 5.2 x 6.8 / 197 x 132 x / (flag terminal) SMU-HR 12 55: 9 x 5.5 x 7.9 / 228 x 139 x / SMU-HR 12 75: 10.3 x 6.8 x 7.9 / 261 x 173 x / 26 6 SMU-HR 12 90: 12 x 6.6 x 8.2 / 305 x 168 x / SMU-HR : 13.4 x 6.8 x 8.4 / 341 x 173 x / 34 8 SMU-HR : 13.4 x 6.8 x 11.1 / 341 x 172 x / (flag terminal) Amps to 1.75 Final Volts Per Cell at 25 C / 77 F Type 5min 10min 15min 30min 1hr 3hr 5hr 8hr 10hr 20hr SMU-HR 12 9: SMU-HR 12 18: SMU-HR 12 35: SMU-HR 12 55: SMU-HR 12 75: SMU-HR 12 90: SMU-HR : SMU-HR :

41 AlphaCell SMU-F Front Access VRLA Battery > Power range from 50 to 170AH > Strong corrosion-resistant grid design > Deep cycle capability > Deep cycle discharge recovery > Optional rugged flame-retardant casing to UL94-VO > 3-year full warranty AlphaCell SMU-F Specifications Standard Warranty: 3yr full plus 12yr pro-rated Battery Type: Valve regulated lead acid Range of Capacity: 50 to 170AH Recommended Float Voltage: 20 C / 68 F Operating Temperature: -15 to 40 C / 5 to 104 F Terminal Type: Threaded copper insert front terminal adapter 39 Mechanical Type Dimensions- L x W x H (in/mm) Weight (lb/kg) Top Access Stud Hole Size (mm) Front Access Stud Size (mm) SMU-F FR: 15.4 x 4.1 x 8.9 / 390 x 105 x / SMU-F FR: 21.9 x 4.1 x 8.9 / 558 x 105 x / SMU-F FR: 15.6 x 4.1 x 10.6 / 395 x 105 x / SMU-F FR: 20.1 x 4.3 x 9.4 / 511 x 110 x / SMU-F FR: 21.9 x 4.9 x 10.6 / 558 x 125 x / SMU-F FR: 21.9 x 4.9 x 11.1 / 558 x 124 x / Amps to 1.75 Final Volts Per Cell at 25 C / 77 F Type 5min 15min 30min 1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 12hr 20hr 24hr SMU-F FR: SMU-F FR: SMU-F FR: SMU-F FR: SMU-F FR: SMU-F FR: Valve-Regulated Batteries

42 AlphaCell SMU-C Deep Cycle VRLA Battery > Power ranges available: 6V from 4.5 to 12AH; 12V from 4.5 to 200AH > Strong corrosion-resistant grid design > Rugged flame-retardant ABS casing to UL94 - VO AlphaCell SMU-C Specifications Standard Warranty: Battery Type: Range of Capacity: Recommended Float Voltage: 3yr full plus 7yr prorated Valve-regulated lead acid 4.5 to 200AH 6V = V (-10mV/ C) 12V = V (-20mV/ C) Operating Temperature: 25 C / 77 F Mechanical Type Nominal Voltage Nominal Capacity (20hr) Dimensions- L x W x H (in/mm) Weight (lb/kg) Terminal 40 Valve-Regulated Batteries SMU-C 6 4.5: 6V 4.5AH 2.8 x 1.9 x 4 / 70 x 47 x / 0.8 A SMU-C 6-7: 6V 8AH 5.9 x 1.3 x 3.7 / 151 x 34 x / 94 A SMU-C 6-12: 6V 13.2AH 5.9 x 2 x 3.7 / 151 x 50 x / 1.9 A SMU-C : 12V 4.5AH 3.5 x 2.8 x 4 / 90 x 70 x / 1.7 A SMU-C 12-7: 12V 8AH 5.9 x 2.6 x 3.7 / 151 x 65 x / 2.6 A SMU-C 12-12: 12V 13.2AH 5.9 x 3.9 x 3.7 / 151 x 98 x / 4 B SMU-C 12-14: 12V 14AH 5.9 x 3.9 x 3.7 / 151 x 98 x / 4.2 B SMU-C 12-18: 12V 20AH 7.1 x 3 x 6.6 / 181 x 77 x / 6 C SMU-C 12-26: 12V 28AH 6.9 x 6.5 x 4.9 / 175 x 166 x / 8.9 C SMU-C 12-28: 12V 28AH 6.5 x 5 x 6.9 / x / 8.5 C SMU-C 12-30: 12V 30AH 6.6 x 5 x 6.8 / 167 x 126 x / 10.2 C SMU-C 12-35: 12V 35AH 7.7 x 5.1 x 6.3 / 195 x 130 x / 10.5 D SMU-C 12-40: 12V 40AH 7.8 x 6.5 x 6.7 / 197 x 165 x / 13.7 E SMU-C 12-55: 12V 56AH 9 x 5.4 x 8.1 / 229 x 138 x / 17 F SMU-C 12-65: 12V 66AH 14 x 6.6 x 7.1 / 355 x 167 x / 22.7 G SMU-C 12-75: 12V 76AH 10.2 x 6.6 x 8.2 / 258 x 168 x / 23 F SMU-C 12-90: 12V 92AH 12 x 6.6 x 8.2 / 305 x 168 x / 30 F SMU-C : 12V 102AH 13 x 6.8 x 8.5 / 330 x 172 x / 31 L SMU-C : 12V 122AH 15.9 x 6.9 x 8.2 / 405 x 175 x / 38 H SMU-C : 12V 136AH 13.4 x 6.8 x 11.2 / 341 x 172 x / 42.5 M SMU-C : 12V 154AH 19.1 x 6.8 x 9.5 / 485 x 172 x / 45 J SMU-C : 12V 202AH 20.6 x 9.6 x 8.6 / 522 x 243 x / 61 K

43 AlphaCell SMU-C Deep Cycle VRLA Battery > 10+ year design life > 3-year, 100% full warranty > Applications: UPS, medical equipment, control system AlphaCell SMU-C Terminal Configurations Terminal A Terminal B Terminals C.D.E.F.G.H.J.K Terminals L, M 4.75mm(.187inch) 0.8mm(.031inch) 6.35mm(.250inch) 0.8mm(.031inch) A E C A B 6.35mm(.250inch) 3.15mm(.124inch) 6.35mm(.250inch) 3.15mm(.124inch) B D C Terminal Type A (in/mm) B (in/mm) C (in/mm) D (in/mm) E (in/mm) C 0.55 / / / / / 5.5 D 0.59 / / / / / 5.5 E 0.65 / / / / / 6.4 F 0.71 / / / / / 7.8 G 0.71 / / / / / 6.5 H 1.02 / / / / / 8.8 J 1.02 / / / / / 8.7 K 1.02 / / / / / 9.5 L 0.79 / / / M 0.79 / / / SMU-C Discharge Current 25 C /77 F to 1.75VPC) SMU-C Discharge Power 25 C /77 F to 1.75VPC) Minutes Hour(s) Minutes Hour(s) Type Type SMU-C 6 4.5: SMU-C 6 4.5: SMU-C 6-7: SMU-C 6-7: SMU-C 6-12: SMU-C 6-12: SMU-C : SMU-C : SMU-C 12-7: SMU-C 12-7: SMU-C 12-12: SMU-C 12-12: SMU-C 12-14: SMU-C 12-14: SMU-C 12-18: SMU-C 12-18: SMU-C 12-26: SMU-C 12-26: SMU-C 12-28: SMU-C 12-28: SMU-C 12-30: SMU-C 12-30: SMU-C 12-35: SMU-C 12-35: SMU-C 12-40: SMU-C 12-40: SMU-C 12-55: SMU-C 12-55: SMU-C 12-65: SMU-C 12-65: SMU-C 12-75: SMU-C 12-75: SMU-C 12-90: SMU-C 12-90: SMU-C : SMU-C : SMU-C : SMU-C : SMU-C : SMU-C : SMU-C : SMU-C : SMU-C : SMU-C : Valve-Regulated Batteries

44 AlphaCell SMU-M Modular Sealed Lead Acid Battery > Power range available in 2V from 200 to 2000AH > Modular unit structure allows for minimal footprint > Insulated cell terminals allow easy maintenance and replacement AlphaCell SMU-M Specifications Standard Warranty: 2yr full plus 16yr pro-rated Service Life: 18yr design life Battery Type: Valve-regulated lead acid Range of Capacity: 100 to 2000AH Recommended Float Voltage: 20 C / 68 F Operating Temperature: 25 C / 77 F Terminal Type: Threaded copper insert Height Width Length 42 Valve-Regulated Batteries Mechanical Type Dimensions- L x W x H (in/mm) Weight (lb/kg) Stud Hole Size (mm) SMU-M FR: 3.7 x 7.2 x 14.2 / 94.5 x 184 x / SMU-M FR: 4.8 x 7.2 x 14.2 / 123 x 184 x / 19 8 SMU-M FR: 6.5 x 7.2 x 14.2 / 166 x 184 x / 26 8 SMU-M FR: 7.7 x 7.2 x 14.2 / x 184 x / 31 8 SMU-M FR: 8.8 x 7.2 x 14.2 / 223 x 184 x / 37 8 SMU-M FR: 6.1 x 9 x 21.9 / 154 x 229 x / 52 8 SMU-M FR: 7.3 x 9 x 21.9 / 186 x 229 x / 62 8 SMU-M FR: 13.7 x 9.2 x 21.9 / 349 x 233 x / 21 8

45 AlphaCell SMU-M Modular Sealed Lead Acid Battery > Strong corrosion resistant grid design > Rugged flame-retardant ABS casing to UL94-VO AlphaCell SMU-M AMPS To 1.75 Volts Per Cell At 25 C / 77 F Type 5 min 10 min 15 min 20 min 30 min 40 min 50 min 60 min 90 min SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: Type 2 hr 3 hr 4 hr 5 hr 6 hr 7 hr 8 hr 9 hr 10 hr 12 hr 24 hr SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: SMU-M FR: Valve-Regulated Batteries

46

47 Battery Rack Systems > Flexibility and versatility via modular design > All main rack components fabricated from powdercoated steel > Polyethylene powdercoating provides electrolyte protection and electrical insulation > Can be upgraded to meet zone 1-4 seismic requirements > Custom configurations available Front view, two-step battery rack AlphaRac battery racks are specifically designed for the industrial market and can accommodate stationary battery models of all types. These racks are flexible, strong, electrolyte-protected and easy to install. Engineered with a modular design of the utmost flexibility, they can be used with virtually any battery brand or model. When combined with optional components, AlphaRac systems can be upgraded to meet the Uniform Building Code for Seismic Zones 1-4. For unique battery system requirements, custom designed battery racks can be constructed. We maintain a large inventory of racks in stock, ready for immediate shipment. Applications include power generation facilities, substations, electrical utilities, transportation systems, communication networks and other enterprises with unique powering requirements. AlphaRac Battery Racks Durable Customizable Flexible Configurations 45 All primary components are polyethylene-coated steel (coating thickness 500µm) for strength, acid-resistance and electrical isolation. Part # 2P-2G-670H/700 Part # 2P-2G-670H/900-SE Part # 2G-470/600 AlphaRac battery racks can be designed to meet special applications or unusual installation requirements. Additional components are available to upgrade a standard AlphaRac to a seismic-rated system designed to meet the requirements of the Uniform Building Code for seismic zones 1-4. Adjustable Modular Economical AlphaRac battery racks are provided in a wide range of configurations. Rack variations include: One to six tiers Two to four step Two tier-two step to Two tier-four step. Battery Rack Systems Acid-resistant adjustable feet permit leveling up to 0.6 inches. Sliding rails allow fine tuning adjustments during installation. AlphaRac Model Number Description Part # 2G-470/700 Part # 2P-350/1400 Part # 2G-470/700 AlphaRac s modular design allows for system versatility and simplifies the process of ordering, installation and relocation. AlphaRac s modular construction permits the smallest possible rack configurations, helping to maximize space and minimize costs. xx - xx - xxx / xxxx (xx) Number of Tiers Number of Rows Depth (mm) Length (mm) Number of Battery Rows 1P = 1 Tier 2G = 2 Step These dimensions are determined by the (r2) = 2 Rows 2P = 2 Tier 3G = 3 Step rack design. (r3) = 3 Rows 3P = 3 Tier 4G = 4 Step (r4) = 4 Rows 4P = 4 Tier 5P = 5 Tier 6P = 6 Tier Model numbers are custom to the specific rack designs. For example, an AlphaRac battery rack with the model number: 2P-2G-670/1800, implies the rack has 2 tiers, 2 rows per tier, is 670mm deep and 1800mm long. Similarly, a battery rack with the model number 3P-500/600(r3) indicates 3 tiers, 500mm in depth, 600mm in length and 3 rows of batteries per tier. Seismic racks are noted with a seismic designator at the end of the model number.

48

49 Specialized Systems > Backup Power For Switchgear Equipment Because of the variation in powering needs and situations, switchgear design and modification packages are highly customized. Alpha Industrial Power s applications engineers work with you to design, build or modify a DC or AC backup system to meet your energy needs. > Energy Conversion Hybrid systems that incorporate photovoltaics, wind and specialized battery cells (energy storage) provide improved reliability. Hybrid power systems can generate power in two ways: by wind with built-in wind turbines and by sun via photovoltaic panels. These systems are ideal for things such as telecommunications, lighting and security applications. > Solar Power Systems (SPS) Alpha Energy Solar Power Systems derive energy from the sun to provide 12, 24 or 48 Volt electricity. The energy collected by the photovoltaic array supplies the necessary load while also storing energy in a bank of industrial-grade, maintenance-free, deep cycle batteries. The battery bank then powers the system after the sun goes down. > Hybrid Power Systems (HPS) Hybrid Power Systems incorporate multiple power generation sources to provide redundancy and ensure power in critical situations. By incorporating an AlphaGen generator, an HPS system is able to compensate for larger power load requirements and/or obstructed weather conditions, like cloud coverage or low sun exposure. > AC/DC Hybrid System The Hybrid Power Plant is ideal for telecommunications providers, security, military and pipeline companies who require the benefits and security of solar electricity in mission critical applications. These versatile Power Plants are highly configurable with diverse AC and DC input and output options. This means it is easy to custom-configure systems to include inverters, DC converters, breakers, alarms, batteries and solar controllers. > Custom Battery Racks and Cabinets To meet your unique design requirements, special racks and cabinets can be designed and incorporated, offering flexibility and versatility. 47 Specialized Systems

50

POWER kva

POWER kva TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power

More information

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC) TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

POWER kva

POWER kva +44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out) TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 400/500 kw With eboost Technology TLE Series UPS 400/500 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01

More information

Liebert. FP 50Z kva

Liebert. FP 50Z kva Liebert FP 50Z 5 250 kva Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at a lower cost when search and social

More information

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH

More information

Industrial Chargers and

Industrial Chargers and Industrial Chargers and DC Systems SPR - Single Phase Rectifier TPR - Three Phase Rectifier 12V 250V 5A 1000A Designed for all Industrial applications Oil & Gas, Petrochemicals Offshore, Onshore, Pipelines

More information

Aurora Single Phase Emergency Lighting Inverters

Aurora Single Phase Emergency Lighting Inverters Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

TLE Series UPS 750/1000 kw With eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology TLE Series UPS 750/1000 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER Evo Series battery charger designed with YOU in mind. Evo Series battery charger is a next generation SCR-based utility battery charger. This evolutionary

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series

More information

Technical Data Sheets

Technical Data Sheets Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

Illuminator Series CR NEMA 3R

Illuminator Series CR NEMA 3R Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva Power Safety Protect 8. Industrial UPS Protect 8.31 Single Phase output 10 kva 120 kva Protect 8.33 Three Phase output 10 kva 120 kva 400 V AC input 220 V DC The Building Block UPS Engineering is our Business

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT30K Highlights On-line double-conversion topology, VFI operation

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

MKN-DSP SERIES - THREE PHASE

MKN-DSP SERIES - THREE PHASE Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 200-250 - 300 PurePulse CE S3 TM SG Series 160 PurePulse CE S3 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous

More information

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting

More information

Industrial PFC UPS System

Industrial PFC UPS System Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 100 &120 PurePulse TM SG Series 60 & 80 PurePulse SGSE_060-120_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work Digital Energy Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems: TECHNICAL GUIDE SPECIFICATIONS Power-Lite Single Phase, (200 to 490 Watts) UL924 Central Lighting Inverter 1. SCOPE The Emergency Lighting Power System shall be a solid-state single phase unit designed

More information

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE DPP/DPP Digital Process INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE PROVIDING CONTINUITY OF ELECTRICAL POWER DPP/DPP DIGITAL PROCESS POWER Industrial Pulse Width Modulated

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

EVO AT SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41

More information

AME. Rectifier - Battery charger. Industrial applications: Key features:

AME. Rectifier - Battery charger. Industrial applications: Key features: Rectifier - Battery charger AME VRLA batteries, flooded battery or Ni/Cd with output voltage from 24, 48, 110, 220 Vdc up to 150A Industrial applications: Oil&Gas (Petrochemicals Offshore, Onshore, Pipelines);

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company imagination at work QUITO: Elia Liut N45-26 y Edmundo Chiriboga Telf:

More information

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

Master DIALOG INDUSTRY RANGE

Master DIALOG INDUSTRY RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs Emergency devices (lights/alarms) Electro-medical devices Telecommunication devices Industrial applications

More information

D Series: UPS UPTO - 300KVA - Three / Three Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction

More information

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP) Local Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Product Specifications

Product Specifications Product Specifications Guide Specification for FirstLine 10Kva, 15Kva, and 20Kva Three-Phase, On-Line Uninterruptible Power Supply 4-15-10 301 Gaddis blvd, Dayton, OH 45403, USA Telephone: (866) 261-2257,

More information

AT SERIES EVO BATTERY CHARGER

AT SERIES EVO BATTERY CHARGER AT SERIES EVO BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T hindlepowerinc.com 610-330-9000 AT Series evo. A battery charger designed with YOU in mind. AT Series evo is HindlePower s next generation

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT40K Highlights On-line double-conversion topology, VFI operation

More information

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP) LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

EMEX. Central Battery Systems Emergency Lighting

EMEX. Central Battery Systems Emergency Lighting EMEX Central Battery Systems Emergency Lighting 2 Table of Content General Presentation 3 & 4 Single Phase Systems 5 & 6 Three Phase Systems 7 & 8 Optional Features 9 User Interface and Display 10 What

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw DELPHYS GP Green Power 2.0 range 160 to 1000 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

Uninterruptible Power Systems

Uninterruptible Power Systems Sola 4K Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K Industrial UPS series eliminates a wider range of potential power problems

More information

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems. SENTRY HPS HM/HT provides maximum protection for vital mission-critical networks, security applications (electro-medical) and industrial applications thanks to its outstanding mechanical and electrical

More information

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance

More information

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical

More information

PowerPro three phase UPS technical data

PowerPro three phase UPS technical data PowerPro three phase UPS technical data General Specification Model RM/RT10 RM/RT15 RM/RT20 RT30 RT40 RT60 RT80 RT100 RT120 RT160 UPS type Power rating kva 10 15 20 30 40 60 80 100 120 160 kw 8 12 16 24

More information

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT20KX Highlights On-line double-conversion topology, VFI operation

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems EON Model EL3 Three Phase Centralized Emergency Lighting Inverter General Specification 10KW 33KW Systems 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements

More information

POWERTRONIX QUASAR 5-40 KVA

POWERTRONIX QUASAR 5-40 KVA POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251

More information

Technical data sheets

Technical data sheets GE Digital Energy Technical data sheets Digital Energy Uninterruptible Power Supply Series UPS 6-10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41

More information

Technical Specification SENTINEL PRO

Technical Specification SENTINEL PRO Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES

More information

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III 1. SCOPE A. The Central Lighting Inverter shall be a solid-state three phase system designed to provide

More information

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw MODULYS RM GP Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw 19 OBJECTIVES The aim of these specifications is to provide the information required to prepare the system and installation

More information

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw MODULYS RM GP Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw 9 OBJECTIVES The aim of these specifications is to provide the information required to prepare the system and installation

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

On-line, Single Phase, Double Conversion UPS

On-line, Single Phase, Double Conversion UPS V Series Standard Universal Tower/Rack Mount 1, 2, 3 kva On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven Digital Signal Processor (DSP) achieving high reliability, while

More information

POWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER

POWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER POWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER GENERAL SCOPE This guide provides technical information and specifications for OnLine Power s Power Wave 1 Central

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model UniStar III Series 1, 2, & 3kVA Tower Model On-line, Single-phase UPS System The UniStar III is a sophisticated yet affordable single phase, double conversion UPS system. It offers on-line technology and

More information

Master Plus kva

Master Plus kva Local Area Networks (LAN) ServerS Data Centers Telecommunication devices e-business (Servers Farms, ISP/ASP/POP) Industrial Processes Industrial PLCs Electromedical Devices Emergency Devices (lights/alarms)

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4 USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE

More information

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems EON Model EL3 Three Phase Centralized Emergency Lighting Inverter General Specification 40KW 55KW Systems 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements

More information

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Series. On-line, Single-phase Parallel Redundant UPS System.   6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM Series 6 and 10 kva Rack Mount On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set

More information

Crucial Power Products

Crucial Power Products TECHNICAL GUIDE SPECIFICATIONS WAVE RIDER 1 SINGLE-PHASE, (2.1 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER 1. GENERAL 1.1 SCOPE Crucial Power Products This guide provides technical information and specifications

More information

Keatec Energy Catalogue 2018 Telecommunications

Keatec Energy Catalogue 2018 Telecommunications Keatec Energy Catalogue 2018 Telecommunications Keatec Energy designs, manufactures, installs and services DC and AC uninterruptible power solutions for Telecommunication, Commercial Information Technology

More information

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass APC Smart-UPS VT, 24 kw / 30 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9

More information

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS MODEL NUMBER: S3M60KX Highlights Best-in-class footprint and power density minimize space requirements for up to 60kVA

More information

UPS Multi Sentry 10-20kVA

UPS Multi Sentry 10-20kVA The Multi Sentry series is ideal for protecting data centres and telecommunications systems, IT networks and critical systems in general, where the risks connected with poor energy supply can compromise

More information

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS Tender Paper TECHNICAL SPECIFICATIONS FOR 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS Contents 1. General 2. Tender submission requirements 3. Environmental

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality

More information