1 Keatec Energy Catalogue 2018 Telecommunications Keatec Energy designs, manufactures, installs and services DC and AC uninterruptible power solutions for Telecommunication, Commercial Information Technology (IT), Public Safety and Industrial clients across the Americas.

2 Tle o on en e ol e e ol e e onolle o e hel e o e l n e ol n ee nlone n ee ll ell o e oo e e on Te n l ee ee h on ee ee e n en n e ee n e on o o e e ee e p n eo n e e e en e e Telephone le n hooo e o n e n n e no ol n e e o e o Telephone ee ene o le ee ene o

3 RECTIFIER MODULE NESPACE Series Rectifer Module 2 kw 42 A 48 Vdc NESPACE Rectifier Modules deliver outstanding reliability and world-leading power density. Ideally suited for 48V telecom and other applications where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Power density 1.41 W/cm 3 Wide input voltage range Vac 1ph Output Voltage vs Output Current Io (A) High operating temperature range Operating -40 to +75 C, full power -40 to +55 C Vo (Vdc) High reliability Efficient thermal design and self-protection features ensure high reliability Hot swappable Output Power vs Input Voltage 2000 > Excellent EMC performance Low interference and low susceptibility Po (W) 800 > Worldwide certifications UL and CE 0 > Vi (Vac) 285 > 297 keatecenergy.com

4 RECTIFIER MODULE NESPACE Series Rectifer Module 2 kw 42 A 48 Vdc SPECIFICATIONS AC Input Nominal voltage 230 Vac 1ph Range Vac 1ph Frequency 45~66 Hz Inrush 20 A at nominal input, full load Efficiency Up to 96% Power factor >0.99 at 50% load or more Protection Under and over voltage Mains fuse in both lines DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Protection 54.0 Vdc Vdc 2000 W at >176 Vac input 1262 W at 120 Vac input 800 W at 85 Vac input 37 A at 54V, input >176 Vac 23 A at 54V, input 120 Vac 14.8 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <250 mv, p-p, <20 mv rms Overvoltage at 59Vdc (recycle input to reset) Power de-rating Thermal shutdown General Specifications Cooling MTBF Acoustic noise Operating temperature Storage temp Humidity Single fan (front to back airflow) >350,000 hours <55 dba (at nominal input and full load, ambient <40 C) -40 to +75 C (-40 to +55 C full load, de-rated above 55 C) -40 to +85 C 95% non-condensing H x W x L mm 41.0 (1U) x x Weight kg 2.18 Monitoring and NESPACE KA Monitoring Control Unit control Communication CAN Bus protocol Standards Safety IEC , UL EMC EN Class A (emission) IEC (electrostatic discharge) IEC (radiated immunity) IEC (fast transients) IEC (surge immunity) IEC (conducted immunity) IEC (voltage dips) IEC (voltage interruptions) IEC (fluctuations & flicker) Certification UL, CE, CB Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS NESPACE Series Rectifier Module 2kW 42A 48Vdc English

5 RECTIFIER MODULE NESPACE Series Rectifer Module 3 kw 62 A 48 Vdc NESPACE Rectifier Modules deliver outstanding reliability and world-leading power density. Ideally suited for 48V telecom and other applications where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and high power density Max efficiency 96% Power density 2.11 W/cm 3 Wide input voltage range Vac 1ph Output Voltage vs Output Current Io (A) High operating temperature range Operating -40 to +75 C, full power -40 to +45 C Vo (Vdc) High reliability Efficient thermal design and self-protection features ensure high reliability Hot swappable Output Power vs Input Voltage 3000 > Excellent EMC performance Low interference and low susceptibility Po (W) 1300 > Worldwide certifications UL and CE 0 > Vi (Vac) 285 > 297 keatecenergy.com

6 RECTIFIER MODULE NESPACE Series Rectifer Module 3 kw 62 A 48 Vdc SPECIFICATION AC Input Nominal voltage 230 Vac 1ph Range Vac 1ph Frequency 45~66 Hz Inrush 25 A at nominal input, full load Efficiency Up to 96% Power factor > 0.99 at 50% load or more Protection Under and over voltage mains fuse in both lines DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Overvoltage protection 54.0 Vdc Vdc 3000 W at >176 Vac input 1954 W at 120 Vac input 1300 W at 85 Vac input 55.5 A at 54V, input >176 Vac 36.2 A at 54V, input 120 Vac 24.1 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <300 mv, p-p, <20 mv rms Overvoltage at 59 Vdc (recycle input to reset) Power de-rating Thermal shutdown General Specifications Cooling MTBF Acoustic noise Operating temperature Storage temperature Humidity Single fan (front to back airflow) >450,000 hours <55 dba (at nominal input and full load, ambient <40 C) -40 to +75 C (-40 to +45 C full load, de-rated above 45 C) -40 to +85 C 95% non-condensing H x W x L mm 41.0 (1U) x x Weight kg 2.30 Monitoring and Control Communication protocol NESPACE KA Monitoring Control Unit CAN Bus Standards Safety IEC , UL EMC Certification EN Class A (emission) IEC (electrostatic discharge) IEC (radiated immunity) IEC (fast transients) IEC (surge immunity) IEC (conducted immunity) IEC (voltage dips) IEC (voltage interruptions) IEC (fluctuations & flicker) UL, CE, CB Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS NESPACE Series Rectifier Module 3kW 62A 48Vdc English

7 RECTIFIER MODULE NESPACE Series Rectifer Module Monitoring Control Unit KA NESPACE Monitoring and Control Unit KA enables remote monitoring and control over systems integrating NESPACE Rectifier Modules. FEATURES Faceplate display and control LCD screen, LEDs and four button interface Remote monitoring and control Monitoring and control of up to 32 NESPACE rectifier modules RS232, SNMPv1, SNMPv2c, Modbus Battery management Temperature compensated charging, boost, equalize and current settings, capacity test System management Input and output alarms, low voltage disconnects (LLVD, BLVD) Excellent EMC performance Low interference and low susceptibility Worldwide certifications CE, UL (pending) keatecenergy.com

8 RECTIFIER MODULE NESPACE Series Rectifer Module Monitoring Control Unit KA SPECIFICATION Functions System control and monitoring Battery management Compatible rectifiers Remote Monitoring and Control External communication Control up to 32 rectifiers LVD functions Configurable alarms and settings Event log (1000 entries) Password management Temperature compensation Low voltage disconnect Capacity test Charge current limit Boost and equalize charge settings Nespace Digital Rectifiers RS232, TCP/IP, Ethernet, SNMPv1, SNMPv2, Modbus General Specifications Cooling Convection MTBF > 250,000 hrs Operating temperature - 40 to 75 o C Storage temperature - 40 to 80 o C Humidity (operating) 0 to 90% non-condensing Altitude 2,000 m H x W x L(mm) 41 (1U) x 108 x Weight kg 0.3 Standards Certification CE, UL (pending) Features DC input range Vdc Montoring AC input voltage DC output voltage Load current Battery current Battery cabinet temperature Individula module status Battery cell voltages Digital input alarms Up to 8 Digital outputs Up to 8, dry contact (8) LVD BLVD, LLVD Interface LCD, LED, buttons (4) Languages English Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS NESPACE Series Rectifier Module Monitoring Control KA English

9 RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 4 kw 83 A 48 Vdc with Distribution NESPACE Series Rectifier Modules in power shelf system with front DC fuse protection, rear DC load connections, dry contact alarms, and a monitoring and control module. Ideally suited for 48V telecom power plants where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Two rectifiers up to 4 kw total output Wide input voltage range Vac 1Ph High operating temperature range Operating -40 to +75 C, full power -40 to +55 C Advanced battery management Temperature compensated charging Boost, equalize and DC current settings Battery capacity test Flexible, scalable and reliable Hot swappable rectifier modules Front access to 15x DC output fuses Rear access to 15x DC output ports and 15x ground ports Rear access to 6x dry contact alarms RS232 port TCP/IP Ethernet port keatecenergy.com

10 RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 4 kw 83 A 48 Vdc with Distribution keatecenergy.com

11 SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 4 kw 83 A 48 Vdc with Distribution AC Input 4kW Power Shelf (2 x 2kW) AC Supply 1 Phase 3 Wire Nominal Voltage 230 Vac Range Vac Frequency 47~63 Hz Efficiency Up to 96% DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Protection Vdc Vdc 4,000 W at >176 Vac input 2,524 W at 120 Vac input 1,600 W at 85 Vac input 74 A at 54V, input >176 Vac 46 A at 54V, input 120 Vac 29.6 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <250 mv, p-p Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution DC output 15 DC ground 15 Dry contact alarms 6 General Specifications Modules NESPACE 2 kw, NESPACE Monitoring Control Unit KA Communication RS232 for PC, TCP/IP Cooling Forced air Shelf H x W x L mm 44.4 (19 1U) x 446 x 408 Temperature Operating -10 to +75 C, derating of 2 kw module above C / Storage -40 to +85 C Altitude < 3000 M Humidity 95% non-condensing Standards: Shelf (pending) Standards: Rectifier UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 4kW 83A 48V with Distribution English

12 RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 6 kw 125 A 48 Vdc with Bulk Distribution NESPACE Series Rectifier Modules in power shelf system with rear DC bulk output connection, dry contact alarms, digitial inputs, and a monitoring and control module. Ideally suited for 48V telecom power plants where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Three rectifiers up to 6 kw total output Wide input voltage range Vac 1Ph High operating temperature range Operating -40 to +75 C, full power -40 to +55 C Advanced battery management Temperature compensated charging Boost, equalize and current settings Battery capacity test Flexible, scalable and reliable Hot swappable rectifier modules Rear access to bulk DC output and DC ground Rear access to 6x dry contact alarm ports Rear access to 4 digital input ports RS232 port TCP/IP Ethernet port keatecenergy.com

13 RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 6 kw 125 A 48 Vdc with Bulk Distribution keatecenergy.com

14 SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 6 kw 125 A 48 Vdc with Bulk Distribution AC Input 6kW Power Shelf (3 x 2kW) AC Supply 1 Phase 3 Wire Nominal Voltage 230 Vac Range Vac Frequency 47~63 Hz Efficiency Up to 96% DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Protection Vdc Vdc 6000 W at >176 Vac input 3,786 W at 120 Vac input 2,400 W at 85 Vac input 111 A at 54V, input >176 Vac 69 A at 54V, input 120 Vac 44.4 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <250 mv, p-p Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution DC output 1 DC ground 1 Dry contact alarms 6 Digital inputs 4 General Specifications Modules NESPACE 2 kw, NESPACE Monitoring Control Unit KA Communication RS232 for PC, TCP/IP Cooling Forced air Shelf H x W x L mm 44.4 (19 1U) x 446 x 408 Temperature Operating -10 to +75 C, derating of 2 kw module above C / Storage -40 to +85 C Altitude < 3000 M Humidity 95% non-condensing Standards: Shelf (pending) Standards: Rectifier UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 6kW 125A 48V with Bulk Distribution English

15 RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 9 kw 187 A 48 Vdc with Distribution NESPACE Series Rectifier Modules in power shelf system with input and output alarms, battery low voltage disconnection, DC load distribution, and a monitoring and control module. Ideally suited for 48V telecom power plants where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Three rectifiers up to 9 kw total output Wide input voltage range Vac 1Ph High operating temperature range Operating -40 to +75 C, full power -40 to +45 C Advanced battery management Temperature compensated charging Boost, equalize and current settings Battery capacity test Flexible, scalable and reliable Hot swappable rectifier modules Two battery breaker postions 125A battery low voltage disconnect Four load distribution breaker postions Six input alarm ports Six output alarm ports TCP/IP Ethernet port keatecenergy.com

16 RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 9 kw 187 A 48 Vdc with Distribution keatecenergy.com

17 SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 9 kw 187 A 48 Vdc with Distribution AC Input 9kW Power Shelf (3 x 3kW) AC Supply 1 Phase 3 Wire or 3 Phase 4 wire Nominal Voltage 230 Vac Range Vac Frequency 47~63 Hz Efficiency Up to 96% DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Protection Vdc Vdc 9000 W at >176 Vac input 5,862 W at 120 Vac input 3,900 W at 85 Vac input A at 54V, input >176 Vac 108.6A at 54V, input 120 Vac 72.3 A at 54V, input 85 Vac + 0.5% Max over entire input range + 0.5% Max over entire load range <300 mv, p-p Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution Battery breakers 2 x 100A BLVD 125 A DC load breakers 2 x 20A, 30A, 50A Input EXT alarm ports 6 Output HW alarm ports 6 DC output points 9 Battery input points 2 x NEG -, 2 x POS + General Specifications Modules NESPACE 3 kw, NESPACE Monitoring Control Unit KA Communication RS232 for PC, TCP/IP, GUI, SNMP Cooling Forced air Shelf H x W x L mm 88.8 (19 2U) x x 402 Temperature Operating -10 to +75 C, derating of 3 kw module above C / Storage -40 to +85 C Altitude < 3000 M Humidity 95% non-condensing Standards: Shelf (pending) Standards: Rectifier UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 9kW 187A 48V with Distribution English

18 RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 12 kw 250 A 48 Vdc with Distribution NESPACE Series Rectifier Modules in power shelf system with input and output alarms, battery low voltage disconnection, DC load distribution, and a monitoring and control module. Ideally suited for 48V telecom power plants where wide input voltage ranges and high operating temperatures are required. FEATURES High efficiency and power density Max efficiency 96% Four rectifiers up to 12 kw total output Wide input voltage range Vac 1Ph High operating temperature range Operating -40 to +75 C, full power -40 to +45 C Advanced battery management Temperature compensated charging Boost, equalize and current settings Battery capacity test Flexible, scalable and reliable Hot swappable rectifier modules AC input surge suppression Ground current sensing with surge suppression LVLD with surge suppression and up to nine DC MCBs LBVD with two battery MCBs Four DC priority MCBs Eight input alarm ports Eight output alarm ports TCP/IP Ethernet port RS232 keatecenergy.com

19 RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 12 kw 250 A 48 Vdc with Distribution keatecenergy.com

20 SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Shelf 12 kw 250 A 48 Vdc with Distribution AC Input 12kW Power Shelf (4 x 3kW) AC Supply 1 Phase 3 Wire Nominal Voltage 230 Vac Range Vac Frequency 47~63 Hz Efficiency Up to 96% DC Output Nominal voltage Range Output power Output current Line regulation Load regulation Ripple and noise Rectifier self protection Vdc Vdc 12,000 W at >176 Vac input 7,816 W at 120 Vac input 5,200 W at 85 Vac input A at 54V, input >176 Vac A at 54V, input 120 Vac 96.4 A at 54V, input 85 Vac + 0.5% Max over entire input range + 1.0% Max over entire load range <300 mv, p-p Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution AC input protection SPD 20KA Ground protection SPD 6.5KA LVBD (MCB) 260A (2 x 100A) LLVD (MCB) 200A with SPD 40KA (3 x 25A, 1 x 32A, 4 x 63A, 1 x open) DC priority MCB 3 x 10A, 1 x 16A Input alarm ports 8 Output alarm ports 8 General Specifications Modules NESPACE 3 kw, NESPACE Monitoring Control Unit KA Communication RS232, TCP/IP, SNMP Cooling Forced air Shelf H x W x L mm x 482 x (19 5U) Temperature Operating -40 to +75 C, derating of 3 kw module above C / Storage -40 to +80 C Altitude < 2000 M Humidity 95% non-condensing Standards: Shelf (pending) Standards: Rectifier UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 12kW 250A 48V with Distribution English

21 RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc NESPACE Series Rectifier Modules in power plant system with individual AC input to rectifiers. Monitoring with input and output alarms, and battery low voltage disconnection. AC Input and DC output surge suppression. Ideally suited for 48V telecom power plants. FEATURES High efficiency Max efficiency 96% Advanced battery management Temperature compensated charging Boost, equalize and current settings Flexible, scalable and reliable Dual racks with 55x 3kW rectifiers N+1 redundancy design Individual AC power input per rectifier Hot swappable rectifier modules 1250A battery breakers 1500A battery low voltage disconnects AC and DC surge suppression DC battery bypass Six input alarm ports Six output alarm ports TCP/IP Ethernet port keatecenergy.com

22 RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

23 RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

24 RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

25 RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

26 RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc keatecenergy.com

27 SPECIFICATIONS RECTIFIER POWER SYSTEM NESPACE Series Power Plant 165 kw 3438 A 48 Vdc AC Input 165kW Power Plant (55 x 3kW) AC Supply 3 Phase 4 Wire 380Vca Nominal Voltage 380 Vac Range 305 ~ 514 Vac Frequency 45~66 Hz Efficiency Up to 96% DC Output Nominal voltage Vdc Range Vdc Output current A at 54 Vdc Line regulation + 0.5% Max Load regulation + 1.0% Max Over current 101 ~ 110% Ripple and noise <300 mv p-p, <2 mvrms Protection Overvoltage at 59 Vdc, thermal shutdown, battery temperature compensation Distribution AC surge suppression 40 kva per rack AC input breaker 225 A 3 P+N per rack Battery bypass Manual bypass switch (on, off, auto) Battery fuse 4 x 1250 A BLVD relay 2 x 1500 A DC load fuse 3 x 1250 A DC bus bar - 48 Vdc 1500 SQ (bus-bar, ground) Input alarm ports 6 Output alarm ports 6 DC surge suppression 6.5 kva per rack General Specifications Modules Communication Cooling H x W x L mm Temperature Altitude Humidity Standards: Rack Standards: Rectifier NESPACE 3 kw, NESPACE Monitoring Control Unit KA RS232 for PC (GUI), TCP/IP, SNMP Forced air 2000 x 1200 x 700 per rack (master, slave) Operating -10 to +50 C, derating of 3 kw module above C / Storage -40 to +80 C < 2000 M 90% non-condensing (pending) UL, CE Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Nespace Series Power Shelf 165kW 3438A 48V English

28 MODULAR INVERTER TM 250S Modular Inverter kva 120 Vac 48 Vdc TM250S Modular Inverter series is a high frequency design with compact size and high power density. Ideally suited for 48V telecom and other applications where operation in high temperatures and N+1 redundancy is required. FEATURES High efficiency and high power density Efficiency up to 87% High power density 3U module High operating temperature range Operating range -20 to +40 C High reliability N+1 redundant Hot swappable Parallel operation DC-AC isolation Dynamic respons time to <20 ms Systems with 1.0, 1.5, 1.6 kva modules STM (max 6.4 kva) with TJ20 Monitor and Bypass Switch XTM (max 12.8 kva) with TJ21 Monitor Module HTM (max 12.8 kva 1 Phase) with TJ10 Monitor and STS HTM (max 38.4 kva 3 Phase) with TJ30 Monitor and STS keatecenergy.com

29 MODULAR INVERTER TM 250S Modular Inverter kva 120 Vac 48 Vdc SPECIFICATIONS AC Output Nominal 120 Vac +2% Range 110, 115, 120 Vac adjustable Frequency Hz +0.1 Hz Power 1.0 kva (TM 251S) 1.5 kva (TM 252S) 1.6 kva (TM 252S VA) Power factor 0.8 Efficiency up to 87% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Dynamic <20 ms response Overload capacity 125%, 10 min 150%, 1 min Connectors Terminal block DC Input Nominal 48 Vdc (-18% to +25%) General Specifications Display LED On/off Cooling Operating temp Full load Islolation Standards Safety EMC Fault, load% Front switch Forced air -20 to +40 C (-4 to +104 F) 1500 V rms EN EN55022 Systems with 1.0, 1.5, 1.6 kva modules STM Max 6.4 kva with TJ20 Monitor and Bypass Switch XTM Max 12.8 kva with TJ21 Monitor Module HTM Max 12.8 kva 1 Phase with TJ10 Monitor and STS HTM Max 38.4 kva 3 Phase with TJ30 Monitor and STS Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TM 250S Modular Inverter kva 120 Vac 48 Vdc English

30 MODULAR INVERTER TM 250S Modular Inverter kva 230 Vac 48 Vdc TM250S Modular Inverter series is a high frequency design with compact size and high power density. Ideally suited for 48V telecom and other applications where operation in high temperatures and N+1 redundancy is required. FEATURES High efficiency and high power density Efficiency up to 88% High power density 3U module High operating temperature range Operating range -20 to +40 C High reliability N+1 redundant Hot swappable Parallel operation DC-AC isolation Dynamic respons time to <20 ms Systems with 1.0, 1.5, 2.0 kva modules STM (max 6.0 kva) with TJ20 Monitor and Bypass Switch XTM (max 16 kva) with TJ21 Monitor Module HTM (max 16 kva 1 Phase) with TJ10 Monitor and STS HTM (max 48 kva 3 Phase) with TJ30 Monitor and STS keatecenergy.com

31 MODULAR INVERTER TM 250S Modular Inverter kva 230 Vac 48 Vdc SPECIFICATIONS AC Output Nominal 230 Vac +2% Range 220, 230, 240 Vac adjustable Frequency Hz +0.1 Hz Power 1.0 kva (TM 251S) 1.5 kva (TM 252S) 2.0 kva (TM 253S) Power factor 0.8 Efficiency up to 88% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Dynamic 20 ms response Overload capacity 125%, 10 min 150%, 1 min Connectors Terminal block DC Input Nominal 48 Vdc (-18 to +25%) General Specifications Display LED On/off Cooling Operating temp Full load Islolation Standards Safety EMC Fault, load% Front switch Forced air -20 to +40 C (-4 to +104 F) 1500 V rms EN EN55022 Systems with 1.0, 1.5, 2.0 kva modules STM Max 6.0 kva with TJ20 Monitor and Bypass Switch XTM Max 16 kva with TJ21 Monitor Module HTM Max 16 kva 1 Phase with TJ10 Monitor and STS HTM Max 48 kva 3 Phase with TJ30 Monitor and STS Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TM 250S Modular Inverter 1-2kVA 230 Vac 48 Vdc English

32 DIGITAL INVERTERS TP 600M Series Standalone Inverter 500 VA - 1 kva 120 Vac 24 Vdc TP 600M Series inverter is a high frequency design with compact size and high power density. Ideally suited for 24V telecom and other applications where high operating temperatures are required. FEATURES High efficiency and high power density Efficiency up to 87% High power density in 1U, 2U, 19 size High operating temperature range Operating range -20 to +60 C, full power up to +40 C High reliability DC-AC isolation Transfer time to 5-8 ms Flexible Standby design with an integrated utility bypass Selectable AC or DC working mode priority RS232 or RS485 communication port, four dry contacts Certification CE Options Models with LCD keatecenergy.com

33 DIGITAL INVERTERS TP 600M Series Standalone Inverter 500 VA - 1 kva 120 Vac 24 Vdc SPECIFICATIONS AC Output Nominal 100, 110, 120, 127 Vac +2% Frequency Hz +0.1 Hz Nominal (model) 500 VA (605M) 1000 VA (610M) Power factor 0.8 Efficiency up to 87% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Transfer time 5-8 ms Dynamic response < 30 ms Overload capacity 125%, 10 sec 110%, 10 min AC Input Nominal 100/110/120/127 Vac +2% Range -25% + 20% Vac Frequency Hz +10% General Specifications Display LED Mode, fault, battery capacity, load% Alarms Dry contacts (4) Communication RS232 or RS485 (optional) Cooling Forced air Enclosure IP20 Operating temp -20 to +60 C, full power up to +40 C Humidity <95% Islolation 1500 V rms Dimensions H x W x L mm Weight 44 x 436 x 319 (605M) (19, 1U) 88 x 436 x 256 (610M) (19, 2U) 6 kg (605M) 6 kg (610M) Standards Electrical safety EN EMC EN DC Input Nominal 24 Vdc (-17 to +25%) Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TP 610M Series Standalone Inverter 500VA-1kVA 120Vac 24Vdc English

34 DIGITAL INVERTERS TP 600M Series Standalone Inverter 500 VA - 1 kva 230 Vac 24 Vdc TP 600M Series inverter is a high frequency design with compact size and high power density. Ideally suited for 24V telecom and other applications where high operating temperatures are required. FEATURES High efficiency and high power density Efficiency up to 88% High power density in 1U, 2U, 19 size High operating temperature range Operating range -20 to +60 C, full power up to +40 C High reliability DC-AC isolation Transfer time to 5-8 ms Flexible Standby design with an integrated utility bypass Selectable AC or DC working mode priority RS232 or RS485 communication port, four dry contacts Certification CE Options Models with LCD keatecenergy.com

35 DIGITAL INVERTERS TP 600M Series Standalone Inverter 500 VA - 1 kva 230 Vac 24 Vdc SPECIFICATIONS AC Output Nominal 208, 220, 230, 240 Vac +2% Frequency Hz +0.1 Hz Nominal (model) 500 VA (605M) PF VA (610M) PF 0.8 Efficiency up to 88% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Transfer time 5-8 ms Dynamic response < 30 ms Overload capacity 125%, 10 sec 110%, 10 min AC Input Nominal 208/220/230/240 Vac Range -25% +20% Vac Frequency Hz +10% General Specifications Display LED Mode, fault, battery capacity, load% Alarms Dry contacts (4) Communication RS232 or RS485 (optional) Cooling Forced air Enclosure IP20 Operating temp -20 to +60 C, full power up to +40 C Humidity <95% Islolation 1500 V rms Dimensions H x W x L mm Weight Standards Electrical safety IEC EMC EN x 436 x 319 (605M) (19, 1U) 88 x 436 x 256 (610M) (19, 2U) 6 kg (605M) 6 kg (610M) DC Input Nominal 24 Vdc (-17 to +25%) Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TP 610M Series Standalone Inverter 500VA-1kVA 230Vax 24Vdc English

36 DIGITAL INVERTERS TP 600S Series Standalone Inverter 500 VA - 3 kva 120 Vac 48 Vdc TP 600S series inverter is a high frequency design with compact size and high power density. Ideally suited for 48V telecom and other applications where high operating temperatures are required. FEATURES High efficiency and high power density Efficiency up to 87% High power density in 1U, 2U, 19 size High operating temperature range Operating range -20 to +60 C, full power up to +40 C High reliability DC-AC isolation Transfer time to 5-8 ms Flexible Standby design with an integrated utility bypass Selectable AC or DC working mode priority RS232 or RS485 communication port, four dry contacts Certification CE Options Models with LCD keatecenergy.com

37 DIGITAL INVERTERS TP 600S Series Standalone Inverter 500 VA - 3 kva 120 Vac 48 Vdc SPECIFICATIONS AC Output Nominal 100, 110, 120, 127 Vac +2% Frequency Hz +0.1 Hz Nominal (model) 500 VA (605S) 1000 VA (610S) 2000 VA (620S) 3000 VA (630S) Power factor 0.8 Efficiency up to 87% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Transfer time 5-8 ms Dynamic response < 30 ms Overload capacity 125%, 10 sec 110%, 10 min AC Input Nominal 100/110/120/127 Vac +2% Range -25% + 20% Vac Frequency Hz +10% General Specifications Display LED Mode, fault, battery capacity, load% Alarms Dry contacts (4) Communication RS232 or RS485 (optional) Cooling Forced air Enclosure IP20 Operating temp -20 to +60 C, full power up to +40 C Humidity <95% Islolation 1500 V rms Dimensions H x W x L mm Weight 44 x 436 x 319 (605S, 610S) (19, 1U) 88 x 436 x 256 (620S) (19, 2U) 88 x 436 x 321 (630S) (19, 2U) 6 kg (605S) 6 kg (610S) 6 kg (620S) 12 kg (630S) Standards Electrical safety EN EMC EN DC Input Nominal 48 Vdc (-17 to +25%) LVD 40 Vdc Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TP 610S Series Standalone Inverter 500VA-3kVA 120Vac 48Vdc English

38 DIGITAL INVERTERS TP 600S Series Standalone Inverter 500 VA - 5 kva 230 Vac 48 Vdc TP 600S Series inverter is a high frequency design with compact size and high power density. Ideally suited for 48V telecom and other applications where high operating temperatures are required. FEATURES High efficiency and high power density Efficiency up to 88% High power density in 1U, 2U, 19 size High operating temperature range Operating range -20 to +60 C, full power up to +40 C High reliability DC-AC isolation Transfer time to 5-8 ms Flexible Standby design with an integrated utility bypass Selectable AC or DC working mode priority RS232 or RS485 communication port, four dry contacts Certification CE Options Models with LCD keatecenergy.com

39 DIGITAL INVERTERS TP 600S Series Standalone Inverter 500 VA - 5 kva 230 Vac 48 Vdc SPECIFICATIONS AC Output Nominal 208, 220, 230, 240 Vac +2% Frequency Hz +0.1 Hz Nominal (model) 500 VA (605S) PF VA (610S) PF VA (620S) PF VA (630S) PF VA (640S) PF VA (650S) PF 0.7 Efficiency up to 88% THD < 3% linear load, < 5% non-linear load Crest factor 3:1 Transfer time 5-8 ms Dynamic response < 30 ms Overload capacity 125%, 10 sec 110%, 10 min AC Input Nominal 208/220/230/240 Vac Range -25% +20% Vac Frequency Hz +10% DC Input Nominal 48 Vdc (-17 to +25%) LVD 40 Vdc General Specifications Display LED Mode, fault, battery capacity, load% Alarms Dry contacts (4) Communication RS232 or RS485 (optional) Cooling Forced air Enclosure IP20 Operating temp -20 to +60 C, full power up to +40 C Humidity <95% Islolation 1500 V rms Dimensions H x W x L mm Weight Standards Electrical safety IEC EMC EN x 436 x 319 (605S, 610S) (19, 1U) 88 x 436 x 256 (620S) (19, 2U) 88 x 436 x 321 (630S, 640S) (19, 2U) 88 x 436 x 390 (650S) (19, 2U) 6 kg (605S) 6 kg (610S) 6 kg (620S) 12 kg (630S) 15 kg (640S) 15 kg (650S) Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS TP 610S Series Standalone Inverter 500VA-5kVA 230Vac 48Vdc English

40 SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Rectifier KLTE A 54 Vdc 220 Vac Outdoor Rectifier for 4G and LTE mobile networks. FEATURES High efficiency Efficiency up to 90% Wide input voltage range Vac 1ph High operating temperature range Operating -30 to +50 C Reliable convection cooling Standards UL, CE, NEBS Level 3 Optional - Outdoor Battery Cabinet IP55 enclosure Wall mount Pull out battery racks Battery breaker 20A Lock and key security keatecenergy.com

41 SPECIFICATIONS AC Input Nominal 220 Vac 1ph Range Vac Frequency 47~63 Hz Inrush 20 A at nominal input (max cold start) Current 4 A at nominal input (max continuous) Leakage 3.5 ma at 264 Vac Efficiency Up to 90% Input protection Double pole 10 A fuse / 250 Vac Undervoltage Overvoltage DC Output Nominal voltage Adjustment range Output current Line regulation 53.3 Vdc Vdc 13 A max + 0.5% Max over entire input range Load regulation + 0.5% Max Temperature + 0.5% Max regulation Ripple and noise <250 mv, p-p, (10 Hz - 14 MHz) Over current % Output projection Overvoltage < 59 Vdc (recycle input to reset) thermal shutdown battery temperature compensation SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Rectifier KLTE A 54 Vdc 220 Vac General Specifications MTBF 150,000 hours Operating temp -30 to +50 C Storage temp -40 to +85 C Humidity 10-90% non-condensing Cooling Convection cooling Environment NEBS Level 3 Altitude 3,000 m H x W x L 150 x 280 x 110 mm Weight 5 kg Communication High signal indicates DC is within regulation Interface RS485, TCP/IP Standards Electrical safety IEC , UL EMC EN Class A (conducted) IEC (electrostatic discharge) IEC (radiated immunity) IEC (fast transients) IEC (surge immunity) IEC (conducted immunity) IEC (voltage dips) IEC (voltage interruptions) IEC (fluctuations & flicker) Harmonics EN Class D Certification UL, CE LVD CB Optional - Battery Cabinet Environment IP55 Shelf Pull out shelf (2) Configuraton 4 x 12V 12Ah batteries Battery breaker 20A Security Lock and key H x W x L 370 x 260 x 220 mm Weight 25 kg with batteries Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Small Cell Power Series Outdoor Rectifier KTLE A 54Vdc 220Vac English

42 SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Power Cabinet DORS 430K 30 A 54 Vdc 220 Vac Small Cell Power Series Outdoor Power Cabinet for 4G and LTE mobile networks. Wall mounted IP 55 cabinet with battery shelf and outdoor rectifier. FEATURES High efficiency Efficiency up to 90% Wide input voltage range Vac 1Ph High operating temperature range Operating -30 to +50 C Reliable convection cooling Compact Outdoor Cabinet Wall mount IP 55 enclosure Shelf space for 4 x 18 Ah batteries AC utility outlet keatecenergy.com

43 SPECIFICATIONS SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Power Cabinet DORS 430K 30 A 54 Vdc 220 Vac AC Input Nominal 220 Vac 1 ph Range Vac Frequency 57~63 Hz Inrush 50 A at nominal input (max cold start) Leakage 3.0 ma at 220 Vac Efficiency Up to 90% Input protection Double pole 15 A fuse / 250 Vac Undervoltage Overvoltage DC Output Nominal voltage 53.3 Vdc Adjustment range Vdc Output current 30 A max Line regulation + 1.0% Max over entire input range Load regulation + 1.0% Max Temperature + 1.0% Max regulation Ripple and noise <250 mv, p-p, (10 Hz - 14 MHz) Over current % Output projection Overvoltage < 57.5 Vdc (recycle input to reset) thermal shutdown battery temperature compensation Battery Configuration General Specifications MTBF Operating temp Storage temp Humidity Cooling Altitude Enclosure H x W x L Interface 4 x 12V 18 AH (not included) 100,000 hours -30 to +50 C -40 to +75 C 10-90% non-condensing Convection cooling 2,000 m 645 x 400 x 245 mm GUI, input dry contact, alarm Standards Electrical safety IEC , UL EMC EN Class A (conducted) IEC (electrostatic discharge) IEC (radiated immunity) IEC (fast transients) IEC (surge immunity) IEC (conducted immunity) IEC (voltage dips) IEC (voltage interruptions) Harmonics EN Class D Enclosure IP 55 Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Small Cell Power Series Outdoor Power Cabinet DORS430K 30A 54Vdc 220Vac English

44 SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Power Cabinet KLTE-430D 30 A 54 Vdc 220 Vac Small Cell Power Series Outdoor Power Cabinet for 4G and LTE mobile networks. Wall or Pole mounted IP 65 cabinet with outdoor rectifier. External battery optional. FEATURES High efficiency Efficiency up to 90% Wide input voltage range Vac 1ph High operating temperature range Operating -30 to +50 C Reliable convection cooling Compact Outdoor Cabinet Wall or poll mount IP65 AC utility outlet Monitoring Full feature status and alarms Dry contact alarm LED alarm indicators Worldwide certifications UL, CE and NEBS Level 3 keatecenergy.com

45 SPECIFICATIONS SMALL CELL POWER SYSTEM Small Cell Power Series Outdoor Power Cabinet KLTE-430D 30 A 54 Vdc 220 Vac AC Input Nominal 220 Vac 1 ph Range Vac Frequency 47~63 Hz Inrush 20 A at nominal input (max cold start) Current 10 A at nominal input (max continuous) Leakage 3.5 ma at 264 Vac Efficiency Up to 90% Input protection Double pole 15 A fuse / 250 Vac Undervoltage Overvoltage DC Output Nominal voltage Adjustment range Output current Line regulation 53.3 Vdc Vdc 30 A max + 0.5% Max over entire input range Load regulation + 0.5% Max Temperature + 0.5% Max regulation Ripple and noise <250 mv, p-p, (10 Hz - 14 MHz) Over current % Output projection Overvoltage < 59 Vdc (recycle input to reset) Thermal shutdown Battery temperature compensation Battery Configuration General Specifications MTBF Operating temp Storage temp Humidity Cooling Altitude Rectifier H x W x L Communication Interface External (not included) 150,000 hours -30 to +50 C -40 to +85 C 10-90% non-condensing Convection cooling 3,000 m 362 x 250 x 232 mm High signal indicates DC is within regulation RS485, TCP/IP, Dry Contact Alarm Standards Electrical safety IEC , UL EMC EN Class A (conducted) IEC (electrostatic discharge) IEC (radiated immunity) IEC (fast transients) IEC (surge immunity) IEC (conducted immunity) IEC (voltage dips) IEC (voltage interruptions) IEC (fluctuations & flicker) Harmonics EN Class D Environment NEBS Level 3 Certification UL, CE LVD, CB Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Small Cell Power Series Outdoor Power Cabinet KTLE 430D 30A 54Vdc 220Vac English

46 VRLA AND AGM BATTERY GENERAL FEATURES Valve Regulated - Sealed Construction Valve regulated lead acid and AGM batteries are rechargeable and designed for safe, trouble free operation in any position. Ease of Shipment Can be shipped by sea, road or air without special handling and packaging precautions due to their sealed construction. Maintenance Free Operation No need to check the specific gravity of the electrolyte. No requirement to refill electrolyte or add water during normal operation. Cycle or Float Service Suitable for either cycling or floating service Heavy Duty Grids Heavy duty calcium-tin alloy grids extend service life. Compact Design A high power-to-weight ratio battery. Low Self Discharge Lead calcium grids minimize capacity loss during long periods of storage time at room temperature. Wide Operating Temperature Performance over a broad range of ambient temperatures. Impact Resistant Case Impact resistant and non-conductive plastic case. CONSTRUCTION

47 PRINCIPLE OPERATION OF VALVE REGULATED LEAD ACID BATTERY Positive Plate. Negative Plate. Net. PbO2+SO4-+4H + +2e-=PbSO4+H2O - Pb+SO4 +4H + +2e-=PbSO4+H2O - PbO2+2SO4 + 4H + + Pb =2PbSO4+2H2O The gassing and water loss reactions are as follows: Positive Plate. Negative Plate. Net. H2O=2H + +1/2O2+2e - 2H + +2e - = H2 H2O=H2+1/2O2 Note that the gassing reaction generally occurs when the battery is almost totally charged. In the valve regulated battery water loss must be avoided by limiting the escape of hydrogen and oxygen from the battery. Therefore the battery design supports the recombination of the oxygen formed at the positive plate with the hydrogen formed at the negative plate as follows. Negative a. Negative b. Net Negative. Pb+1/2O2+H2SO4=PbSO4 +H2O PbSO4+2H + +2e - =Pb +H2SO4 1/2O2+2H + +2e - =H2O The virtually eliminates the production of free hydrogen at the negative plate during recombination. However it is necessary to ensure that correct charging voltages are used because the construction provides a means of recombining the internally generated hydrogen and oxygen, and suppresses the evolution of hydrogen gas to limit the consumption of water from the electrolyte. Therefore the battery requires no addition of water during its normal life time. Valve regulated batteries are sealed with the exception of a valve that opens when excess pressure builds up inside the battery. The valve automatically reseals itself. The recombination of charge gases is accomplished by allowing oxygen produced at the positive plate to pass through the separator material to the negative plates where the recombination reaction occurs. The valve controls the internal process of the battery to optimize the efficiency of the recombination reaction and minimize the possible expense of electrolyte. NOMINAL CAPACITY The capacity of a battery is the available amount of electrical energy which can be obtained from a fully charged cell. The capacity of a cell is expressed in ampere hours (AH), which is a current-time product. The capacity value is dependent upon the discharge current, the temperature during discharge, the final cutoff voltage and the general history. The nominal capacity of a battery is measured at the 10 hour or 20 hour rate at 25 to a cut-off voltage of 1.75 volts per cell. STORAGE During storage, batteries gradually lose their capacity due to their self-discharge. The self-discharge rate is low and is typically less than 3% per month at 25. Although the self-discharge rate is low, specific precautions must be taken against the battery over self-discharging itself when in storage or not in use. Precautions Against Over Self-discharge a. The batteries should be stored in a clean, cool and dry place b. Storage place should not be affected by sources of radiant heat such as sun, heating units, radiators or steam pipes c. The recommendable storage temperature: 10~20 d. The recommendable storage humidity is as low as possible Charge AdviceStorage Temperature Charging Interval 20 or less 9 months 20~30 6 months 30~40 3 months

48 Temperature above 40 should be avoided. After long term storage, all batteries deliver less than the rated capacity. Full capacity will be obtained after several charge/discharge cycles. For the longest life a battery should be fully charged before being put into storage. Self-Discharge Characteristics Open Circuit Voltage and Remaining Capacity (32 Capacity Retentionratio (%) 40 ( (86 20 (68 5 (41 10 (50 Battery Volts ( ) Storage Time (Months) Capacity (25 ) BATTERY DISCHARGING The capacity of a battery is the available amount of electrical energy which can be obtained from a fully charged cell. The capacity of a battery is expressed in amperehours(ah),which is a current-time product. The capacity value is dependent upon the discharge current, the temperature during discharge, the final cut-off voltage and the general history. The nominal capacity of an battery is measured at the 10 hour or 20 hour rate according to types at 25 to a cut-off voltage of 1.80 volts or 1.75 volts per cell. Battery Selection The battery discharge curve may be utilised in battery selection. However it is suggested that a review is made of the data sheet for each battery size or the chart showing the actual ampere hour capacity of each battery size at various discharge times. Temperature Effect on discharge Capacity The discharge capacity varies according to the temperature during discharge. At low temperature the discharge capacity decreases and at high temperature it increases. the temperature effects on the discharge capacity at various discharge current rates are shown in the graph. Final Acceptable Discharge Voltages The battery cut-off voltage is the volts per cell to which a battery may be discharged safely to maximise battery life, this value is specified according to the actual discharge load and run time. As a rule of thumb, high amp loads and short run times will tolerate a lower cut off voltage, whereas a low amp long run time discharge will require a higher cut off voltage. Terminalv oltage (V) Capacity (%) Discharge Characteristic Curve 3C 2C Discharge current 1C 0.6C Discharge time Cut off Volts/Cell 3CA CA CA CA CA CA C 0.05C 0.27C 0.10C Rating the Capacity at 25 Temperature

49 CHARGING CHARACTERISTICS The characteristics of charging by constant voltage (recommended) are shown in the graph. Standby Use Cycle Use Charge Method Cyclic Operation Float Operation Refresh Charge During Storage 2.40~2.45vpc 2.25~2.30vpc 2.40~2.45vpc Constant Voltage Initial current Initial current Initial current 0.3CA or less 0.3CA or less 0.3CA or less Constant Current Charging current approximately 0.1 CA. Charge time control is also recommended otherwise an overcharge can occur. Not applicable Charging current: approximately 0.1CA Charging Method Ambient Temperature: 25 Note: ensurethe voltage is set correctly. A voltage set too high will increase the corrosion of the positive plates and shorten battery life. A voltage set too low will lead to sulphation of the plates causing loss of capacity and ultimately shortening the life of the battery. BATTERY LIFE Cyclic Use Cycle life is very dependent on the depth of discharge which the battery experiences during each cycle. The number of cycles relating to the depth of discharge is shown in the graph. Effect of Temperature on Charging Voltage Within the normal operating parameters of 20 ~30 voltage compensation for operating temperature may not be necessary. However, to maximise the life of the battery, temperature compensation for operating temperatures outside this temperature range should be considered. Charging voltage compensation for battery temperature: Capacity (%) 100% D.O.D 50% D.O.D 30% D.O.D 1.Float operation: Vt=V-0.003(t-25) 2.Cyclic operation: Vt=V-0.005(t-25) (V=Charging voltage at 25, t=temperature,vt=charging voltage at t ) Number of cycles

50 Floating Use Float use life is very dependent on the temperature at which the battery is float charged. The float life is very long at low temperature (10~20 )but at higher temperature the float life is shortened. Life (Years) Temperature TERMINAL DATA F1 F2 B1 B2 M M M M M M M

51 6-FMH-100 FMH Series For Front Terminal 6-FMH-100 Specifications Nominal Voltage Rated Capacity (20 hour rate) Total Height (with terminals) Dimensions Height length width Weight Characteristics Capacity 77 (25 ) Internal Resistance Capacity affected by Temperature (20hour rate) Self-Discharge 77 (25 ) Max. Discharge Current 77 (25 ) Terminal Charge Cycle (Constant Voltage) Float 12V 100Ah inches(286mm) inches(286mm) inches(395mm) 4.33 inches(110mm) Approx Pound(32.3kg) 20 hour rate (5.0A) 100 Ah 10 hour rate (9.2A) 92 Ah 5 hour rate (16.0A) 80 Ah 1hour rate (60.0A) 60 Ah 15Minute Rate (164A) 41 Ah Full charged Battery 77 (25 ) 4.5 MΩ 104 (40 ) 102% 77 (25 ) 100% 32 (0 ) 85% 5 (-15 ) 65% Capacity after 3 month storage 91% Capacity after 6 month storage 81% Capacity after 12 month storage 60% 800A(5S) M6 Initial Charging Current less than 30A Voltage 14.4~14.7 V / 77 (25 ) Voltage 13.5~13.8V / 77 (25 ) Constant Current Discharge Discharge Curves 77 (25 ) Discharge time Relationship between charge voltage and temperature F.V/Time 5Min 10Min 15Min 30Min 60Min 2H 3H 4H 5H 10H 20H Terminalv oltage (V) (V/6V) (V/12V) (V/CELL) C 1C 0.59C 0.56C CYCLE USE STAND BY USE Ambient temperature ( ) 0.16C 0.09C 0.092C0.05C 0.05C Constant Power Discharge (WATTS PER CELL@25 Cut off voltage V/cell 5min 10min 15min 30min 45min 1h 2h 3h 5h 10h 24h

52 FMH Series For Front Terminal 6-FMH-100 Temperature above 40C should be avoided. After long term storage, the battery capacity will be less than the rated capacity. Full capacity will be achieved after several charge/discharge cycles. For the longest life, the battery should be fully charged before storage. Cycle service life in relation to depth of discharge Constant voltage charge characteristic Charged Volume Current Voltage (%) ( CA) (V) 140 (0.25CA,25 ) Capacity (%) 100% D.O.D D.O.D 50% D.O.D 30% D.O.D CHARGED VOLUME CHARGE VOLTAGE CHARGE CURRENT Number of cycles Charge time(hours) Self-Discharge Characteristics Relationship of OCV and Residual Capacity % (25 ) 0 (32 Capacity (%) 5 (41 10 (50 Residual Capacity ( ) 40 ( (86 20 (68 Storage Time (Months) Temperature effects on capacity Capacity (25 ) Temperature effects float life Capacity (%) CA: Rated Capacity at 25 Life (Years) 6-FMH-100 Temperature Temperature

53 6-FMH-150 FMH Series For Front Terminal 6-FMH-150 Specifications Nominal Voltage Rated Capacity (20 hour rate) Total Height (with terminals) Dimensions Height length width Weight Characteristics Capacity 77 (25 ) Internal Resistance Capacity affected by Temperature (20hour rate) Self-Discharge 77 (25 ) Max. Discharge Current 77 (25 ) Terminal Charge (Constant Voltage) Cycle Float 12V 150Ah inches(288mm) inches(288mm) inches(551mm) 4.33 inches(110mm) Approx.101 Pound(45.9kg) 20 hour rate (7.5A) 150 Ah 10 hour rate (13.8A) 138 Ah 5 hour rate (24.0A) 120 Ah 1hour rate (90.0A) 90 Ah 15Minute Rate (246A) 61.5 Ah Full charged Battery 77 (25 ) 4.0 MΩ 104 (40 ) 102% 77 (25 ) 100% 32 (0 ) 85% 5 (-15 ) 65% Capacity after 3 month storage 91% Capacity after 6 month storage 81% Capacity after 12 month storage 60% 1000A(5S) M6 Initial Charging Current less than 45A Voltage 14.4~14.7 V / 77 (25 ) Voltage 13.5~13.8V / 77 (25 ) Constant Current Discharge Discharge Curves 77 (25 ) Discharge time Relationship between charge voltage and temperature F.V/Time 5Min 10Min 15Min 30Min 60Min 2H 3H 4H 5H 10H 20H Terminalv oltage (V) (V/6V) (V/12V) (V/CELL) C 1C 0.59C 0.56C CYCLE USE STAND BY USE Ambient temperature ( ) 0.16C 0.09C 0.092C0.05C 0.05C Constant Power Discharge (WATTS PER CELL@25 Cut off voltage V/cell 5min 10min 15min 30min 45min 1h 2h 3h 5h 10h 24h

54 FMH Series For Front Terminal 6-FMH-150 Temperature above 40C should be avoided. After long term storage, the battery capacity will be less than the rated capacity. Full capacity will be achieved after several charge/discharge cycles. For the longest life, the battery should be fully charged before storage. Cycle service life in relation to depth of discharge Constant voltage charge characteristic Charged Volume Current Voltage (%) ( CA) (V) 140 (0.25CA,25 ) Capacity (%) 100% D.O.D D.O.D 50% D.O.D 30% D.O.D CHARGED VOLUME CHARGE VOLTAGE CHARGE CURRENT Number of cycles Charge time(hours) Self-Discharge Characteristics Relationship of OCV and Residual Capacity % (25 ) 0 (32 Capacity (%) 5 (41 10 (50 Residual Capacity ( ) 40 ( (86 20 (68 Storage Time (Months) Temperature effects on capacity Capacity (25 ) Temperature effects float life Capacity (%) CA: Rated Capacity at 25 Life (Years) 6-FMH-150 Temperature Temperature

55 6-GFMH-180 FMH Series For Front Terminal 6-GFMH-180 Specifications Nominal Voltage Rated Capacity (10 hour rate) Total Height (with terminals) Dimensions Height length width Weight 12V 180Ah 12.4 inches(320mm) 12.4 inches(320mm) 21.5 inches(546mm) 4.92 inches(125mm) Approx Pound(53kg) Discharge Curves 77 (25 ) Terminalv oltage (V) C 1C 0.59C 0.56C 0.16C 0.09C 0.092C0.05C 0.05C Characteristics Capacity 77 (25) Internal Resistance Capacity affected by Temperature (20hour rate) Self-Discharge 77 (25) Max. Discharge Current 77 (25) Terminal Charge Cycle (Constant Voltage) Float 20 hour rate (9.0A) 180Ah 10 hour rate (16.5A) 165Ah 5 hour rate (28.8A) 144Ah 1hour rate (101A) 101Ah 15Minute Rate (295A) 73.8Ah Full charged Battery 77 (25) 4mΩ 104 (40) 102% 77 (25) 100% 32 (0) 85% 5 (-15) 65% Capacity after 3 month storage 91% Capacity after 6 month storage 81% Capacity after 12 month storage 60% 1050A(5S) M8 Initial Charging Current less than 54A Voltage 14.4~14.7 V / 77 (25) Voltage 13.5~13.8V / 77 (25) Relationship between charge voltage and temperature (V/6V) (V/12V) (V/CELL) Discharge time CYCLE USE STAND BY USE Ambient temperature () Constant Current Discharge 6-GFMH Constant Power Discharge (WATTS PER CELL@

56 FMH Series For Front Terminal 6-GFMH-180 Temperature above 40C should be avoided. After long term storage, the battery capacity will be less than the rated capacity. Full capacity will be achieved after several charge/discharge cycles. For the longest life, the battery should be fully charged before storage. Cycle service life in relation to depth of discharge Constant voltage charge characteristic Charged Volume Current Voltage (%) ( CA) (V) 140 (0.25CA,25 ) Capacity (%) 100% D.O.D D.O.D 50% D.O.D 30% D.O.D CHARGED VOLUME CHARGE VOLTAGE CHARGE CURRENT Number of cycles Charge time(hours) Self-Discharge Characteristics Relationship of OCV and Residual Capacity % (25 ) 0 (32 ) Capacity (%) 5 (41 ) 10 (50 ) Residual Capacity ( ) 40 (104 ) 30 (86 ) 20 (68 ) Storage Time (Months) Temperature effects on capacity Capacity (25 ) Temperature effects float life Capacity (%) CA: Rated Capacity at 25 Life (Years) GFMH-180 Temperature Temperature

57 BATTERY NiCd Battery Te hnolo FEATURES ominal. Ah ated at C5 ( C) M - esigned for Medium discharge rate of 0.5 t A.5 t A L - esigned for a discharge rate lower than 0.5 t A State-of-the-art automated manufacturing ensures consistency and reliability. icd batteries have a service life much longer than that of Lead Acid batteries, which suffer from lead plate shedding and internal corrosion. icd batteries are widely used for outdoor applications because they operate reliably at temperatures up to + 0 C. keatecenergy.com

58 BATTERY KGL Series NiCd Gas Recombination Battery Maintenance free KGL Series Ni- Cd rechargeable batteries use negative oxygen recombination technology and gas recombination vent plugs. State-of-the-art automated manufacturing ensures consistency and reliability. Designed for a discharge rate lower than 0.5 I t A FEATURES Ah Rated at C5 (20 +/- 5 o C) Nominal 1.2 V Long Life Ultra-low water consumption due to high gas recombination efficiency and vent plug technology Pocket plates and internal frames made of steel do not react with the electrolyte Service life can exceed 25 years with virtually no internal corrosion 2,000 cycles with at most a single replacement of electrolyte Operation at Extreme Temperatures -40 C to +60 C Top Quality Materials Plates - horizontal pockets of double perforated steel strips Separator is polypropylene fiber Nickel plated steel terminals Translucent plastic container Easy Handling Maintenance free Top access terminals Flip top vent caps keatecenergy.com

59 SPECIFICATIONS BATTERY KGL Series NiCd Gas Recombination Battery Model C5 Rated Capacity Ah Nominal Voltage Dimensions H x W xl mm Weight kg Terminals Threading Container Material KGL x 134 x x M10 PP KGL x 134 x x M10 PP KGL x 134 x M16 PP KGL x 134 x M16 PP KGL x 134 x M16 PP KGL x 141 x M10 PP KGL x 141 x M10 PP KGL x 141 x M10 PP KGL x 165 x M20 PP KGL x 171 x M20 PP KGL x 171 x M20 PP KGL x 170 x M20 PP KGL x 170 x M20 PP KGL x 276 x x M16 PP KGL x 276 x x M16 PP KGL x 276 x x M16 PP KGL x 291 x x M20 MBS KGL x 291 x x M20 MBS Compliance IEC Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS KGL Series NiCd Gas Recombination Battery English

60 BATTERY KGM Series NiCd Gas Recombination Battery Maintenance free KGM Series Ni- Cd rechargeable batteries use negative oxygen recombination technology and gas recombination vent plugs. State-of-the-art automated manufacturing ensures consistency and reliability. Designed for a medium discharge rate of 0.5 I t A ~ 3.5 I t A FEATURES Ah Rated at C5 (20 +/- 5 o C) Nominal 1.2 V Long Life Ultra-low water consumption due to high gas recombination efficiency and vent plug technology Pocket plates and internal frames made of steel do not react with the electrolyte Service life can exceed 25 years with virtually no internal corrosion 2,000 cycles with at most a single replacement of electrolyte Operation at Extreme Temperatures -40 C to +60 C Top Quality Materials Plates - horizontal pockets of double perforated steel strips Separator is polypropylene fiber Nickel plated steel terminals Translucent plastic container Easy Handling Maintenance free Top access terminals Flip top vent caps keatecenergy.com

61 SPECIFICATIONS BATTERY KGM Series NiCd Gas Recombination Battery Model C5 Rated Capacity Ah Nominal Voltage Dimensions H x W xl mm Weight kg Terminals Threading Container Material KGM x 134 x M16 PP KGM x 134 x M16 PP KGM x 134 x M16 PP KGM x 141 x M16 PP KGM x 141 x M16 PP KGM x 141 x M16 PP KGM x 165 x M20 PP KGM x 165 x M20 PP KGM x 167 x M20 PP KGM x 167 x M20 PP KGM x 170 x M20 PP KGM x 200 x x M16 PP KGM x 200 x x M16 PP KGM x 278 x x M16 PP KGM x 291 x x M20 MBS KGM x 291 x x M20 MBS KGM x 291 x x M20 MBS KGM x 291 x x M20 MBS Compliance IEC Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS KGM Series NiCd Gas Recombination Battery English

62 BATTERY h on Battery Te hnolo FEATURES Maintenance free rack mounted Lion rechargeable batteries are ideal for Telecom applications. Lithium-ion (Lion) batteries deliver high power density, deep cycling capability and a service life much longer than that of Lead Acid batteries. Lion batteries also accept high charge currents and recharge very quickly. Unlike Lead Acid Batteries, Lion Battery packs precisely control the charging process through an on-board Battery Management System (BMS) that communicates with the charging device. Lion batteries are maintenance free and ultimately deliver the lowest total cost of ownership. Lion can be used for outdoor applications because they discharge reliably at temperatures up to +55 C and can be recharged at temperatures up to +40 C. State-of-the-art automated manufacturing ensures consistency and reliability. keatecenergy.com

63 BATTERY LBT Series LiFePo Battery 48 Vdc 50 Ah LBT Series maintenance free rack mounted Lithium-ion rechargeable batteries are ideal for Telecom applications. State-of-the-art automated manufacturing ensures consistency and reliability. Lifetime of up to 15 years, or 6,000 cycles 80% SoC. FEATURES Battery Management System (BMS) State of charge and health management PC management and monitoring software RS232 and RS485 communications Alarms Data storage Operation at Extreme Temperatures Charging 0 C to +50 C Discharging 0 C to +60 C Easy Handling Rack mount - 19 inch Height - 3U Parallel up to 15 batteries Options LCD display screen keatecenergy.com

64 SPECIFICATIONS BATTERY LBT Series LiFePo Battery 48 Vdc 50 Ah LBT 4850 Nominal voltage 51.2 Vdc Nominal capacity 50 Ah / 2.56 kwh (0.2 C, to 43.2 V, at 25 C) Charging cut-off voltage 58.4 Vdc Discharging cut-off voltage 40 Vdc Standard charging current 10 A Max charging 50 A Standard discharging current 10 A Max discharging current 50 A BMS power consumption < 1.5 W H x W x D mm x 480 x Weight kg 27 Discharging temperature 0 to +60 C Charging temperature 0 to +50 C Storage temperature 15 to 25 C Humidity < 80 % Environment IP 30 Protection Over-current, over-voltage, under-voltage, over-temperature, short-cicuit Parallel up to 15 Communications RS232, RS485 Monitoring PC Software (RS 485 or Modbus) Standards IEC 62619, IEC 21A/556CD, RoHS, UN/DOT 38.3, EN , EN , EN 55032, EN55024 Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec LBT Series LiFePo Battery 48V 50A English

65 BATTERY LBT Series LiFePo Battery 48 Vdc 100 Ah LBT Series maintenance free rack mounted Lithium-ion rechargeable batteries are ideal for Telecom applications. State-of-the-art automated manufacturing ensures consistency and reliability. Lifetime of up to 15 years, or 6,000 cycles 80% SoC. FEATURES Battery Management System (BMS) State of charge and health management PC management and monitoring software RS232 and RS485 communication Data storage Alarms Operation at Extreme Temperatures Charging 0 C to +50 C Discharging 0 C to +60 C Easy Handling Rack mount - 19 inch Height - 5U Parallel up to 15 batteries Options LCD display keatecenergy.com

66 SPECIFICATIONS BATTERY LBT Series LiFePo Battery 48 Vdc 100 Ah LBT Nominal voltage 51.2 Vdc Nominal capacity 100 Ah / 5.12 kwh (0.2 C, to 43.2 V, at 25 C) Charging cut-off voltage 58.4 Vdc Discharging cut-off voltage 40 Vdc Standard charging current 20 A Max charging 50 A Standard discharging current 20 A Max discharging current 50 A BMS power consumption < 1.5 W H x W x D mm x 480 x 385 Weight kg 48 Discharging temperature 0 to +60 C Charging temperature 0 to +50 C Storage temperature 15 to 25 C Humidity < 80 % Environment IP 30 Protection Over-current, over-voltage, under-voltage, over-temperature, short-cicuit Parallel up to 15 Communications RS232, RS485 Monitoring PC Software (RS 485 or Modbus) Standards IEC 62619, IEC 21A/556CD, RoHS, UN/DOT 38.3, EN , EN , EN 55032, EN55024 Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec LBT Series LiFePo Battery 48V 100A English

67 PROFESSIONAL SERVICES Preventative Maintenance - Batteries UPS runtime can be greatly reduced by a single degraded battery that adversely affects the performance of the entire string PROFESSIONAL SERVICES Battery state-of-health testing Discharge testing Temperature checks Inspection for leaks and corrosion Clean and tighten connections - UPS availability and performance improves when its supported by healthy batteries - Costly emergency repairs and lost business revenue are avoided when batteries are proactively replaced before a failure - Best practices are followed with the removal and recycling of spent batteries keatecenergy.com

68 PROFESSIONAL SERVICES Preventative Maintenance - Batteries Cycle life is very dependent on the depth of discharge which the battery experiences during each cycle. Float use life is very dependent on the temperature at which the battery is float charged. Float use life is longer at low temperatures (10~20 0 C) but at higher temperatures float use life is shortened. FACTORS AFFECTING BATTERY LIFE AND PERFORMANCE x - Charging at high or low voltage x - Low or excessive charge current x - High room temperatures x - Overcharging or undercharging x - Loose interconnections between batteries in the string x - Improper maintenance - Lead acid batteries lose capacity (runtime) based on age, usage and operating temperature. - Every time a battery is discharge, it shortens the remaining lifetime. - Typically lead acid batteries start to lose capacity and fail within 3-5 years. - Lead acid batteries are electrochemical devices that require regular checks and maintenance. - Discharging and charging of a lead acid battery is an electrochemical process that ultimately results in the destruction of the lead plates (shedding) and the degradation of the electrolyte liquid. - A high battery cell temperature indicates severe internal issues and that battery replacement is required. Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec Services - Preventative Maintenance - Batteries English

69 PROFESSIONAL SERVICES Integration of Power Solutions PROFESSIONAL SERVICES Site Audits, Needs Analysis and System Design Integration of DC Power Plant with Distribution Integration of AC UPS with Distribution Custom Outdoor Power System Enclosures Custom Indoor Battery Racks and Outdoor Enclosures - Free up key resources with delivery of a turnkey system - Accelerate your schedule by having systems manufactured in parallel with site works - Decrease rework and time spent at remote sites with pre-tested systems - Increase quality and finish with factory manufactured enclosures - Factory applied paint can extend the service lifetime of outdoor enclosures Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec Services - Integration of Power Solutions English keatecenergy.com

70 PROFESSIONAL SERVICES System Capacity and Performance Audit Businesses grow, technology changes, and eventually systems require upgrading or replacement PROFESSIONAL SERVICES System Capacity Audit Performance Review Upgrade Assessment Fault Cause Discovery Surge and Ground Protection Review Cooling System Review - Eliminate faults and performance issues causing downtime and lost revenue. - Cost-effectively extend the life of assets with an upgrade or expansion. - Enhance bottom line performance by enhancing system efficiency and reliability. - Restore system to full backup runtime with fresh batteries. Keatec Energy. All rights reserved. Keatec Energy reserves the right to change specifications without notice. DS Keatec Services - System Capacity and Performance Audit English keatecenergy.com

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 400/500 kw With eboost Technology TLE Series UPS 400/500 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power

More information

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

NetSure. 211 Series DC Power System

NetSure. 211 Series DC Power System NetSure 211 Series DC Power System NetSure 211 SERIES KEY FEATURES ysupports Ethernet, SNMP V2 & SNMP V3, ModBus and RS485 communication interfaces enables remote control and monitoring ynetsure rectifiers

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

Aurora Single Phase Emergency Lighting Inverters

Aurora Single Phase Emergency Lighting Inverters Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE

More information

TLE Series UPS 750/1000 kw With eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology TLE Series UPS 750/1000 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw MODULYS RM GP Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw 19 OBJECTIVES The aim of these specifications is to provide the information required to prepare the system and installation

More information

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw MODULYS RM GP Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw 9 OBJECTIVES The aim of these specifications is to provide the information required to prepare the system and installation

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information

Industrial Chargers and

Industrial Chargers and Industrial Chargers and DC Systems SPR - Single Phase Rectifier TPR - Three Phase Rectifier 12V 250V 5A 1000A Designed for all Industrial applications Oil & Gas, Petrochemicals Offshore, Onshore, Pipelines

More information

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out) TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLESM_030-180_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power problems (spikes, surges

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

POWER kva

POWER kva TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

Technical Data Sheets

Technical Data Sheets Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

POWER kva

POWER kva +44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS magellan commercial UPS solutions Magellan Power Modular - Flexible UPS Commercial UPS Solutions 2 MPM3320-60kVA MPM3320-100kVA MPM3320-200kVA MPM3340-400kVA MPM3340-520kVA 2015 W www.magellan-power.com.au

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC) TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series

More information

QUEENSLAND URBAN UTILITIES

QUEENSLAND URBAN UTILITIES DOCUMENT NO : EQUIPMENT NO : PREPRED : CHECKED : PPROVED : SHEET NO : 1 of 6 GENERL 1 Battery Charger DCC Inverters 3 DCDC Converters 4 System Design Life (other than batteries) Years 5 Battery Design

More information

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen. Power Conversion Systems 2005/2006 Schaefer the Power to make it happen. Company profile workforce experience customer orientation flexibility reliability Schaefer Elektronik, founded in 1969, has grown

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT30K Highlights On-line double-conversion topology, VFI operation

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

Technical Specification SENTINEL PRO

Technical Specification SENTINEL PRO Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES

More information

Pure Lead-Tin Technology

Pure Lead-Tin Technology Pure Lead-Tin Technology Pure Lead-Tin technology offers many advantages which include: High overall efficiency High energy density Excellent high rate performance Excellent low temperature performance

More information

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work Digital Energy Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

Industrial Power Supplies

Industrial Power Supplies , Features Switch Mode Power Supplies for DIN-rail Mounting 6 Power Ranges with 2, 3, 6, 12, 20 and 24 A Current (24 VDC Models) Selectable 115/ 230 VAC Input Very low Ripple and Noise EMI complies with

More information

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Series. On-line, Single-phase Parallel Redundant UPS System.   6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM Series 6 and 10 kva Rack Mount On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set

More information

POWERTRONIX QUASAR 5-40 KVA

POWERTRONIX QUASAR 5-40 KVA POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 100 &120 PurePulse TM SG Series 60 & 80 PurePulse SGSE_060-120_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

PowerWave 33 Efficient power protection for today s IT and process-related work environments

PowerWave 33 Efficient power protection for today s IT and process-related work environments ARTICLE OR CHAPTER TITLE PowerWave 33 Efficient power protection for today s IT and process-related work environments Cooling fan UPS control panel Maintenance bypass isolator Input supply isolator Slot

More information

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet for industrial applications Product Data Sheet 720 W / 24 V On-board Battery Charger for industrial applications Features IP65 protection degree Battery selection via GUI, supporting all leading battery

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER Evo Series battery charger designed with YOU in mind. Evo Series battery charger is a next generation SCR-based utility battery charger. This evolutionary

More information

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL Local Area NETWORKS (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc Haze Battery Company Ltd Sealed Lead Acid 6 & 12 Volt Monobloc AGM Range CONSTRUCTION - AGM battery construction is as shown in the diagram below. The positive and negative grids are cast from a calcium

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

Uninterruptible Power Systems

Uninterruptible Power Systems Sola 4K Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K Industrial UPS series eliminates a wider range of potential power problems

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A) A Complete solution for small battery-backed dc instrument power systems. DATASHEET Supply 12Vdc 8A or 24Vdc 6A loads Ideal for RTU s, dataloggers, remote field instrumentation, alarm systems, etc. where

More information

X600. Technical Sheet

X600. Technical Sheet X600 Technical Sheet 2 Inverter + Charge Controller + X600 1 Photovoltaic Modules Stand Alone Technical Sheet Electric Diagram 3 Technical Characteristics Contacts X600: Electric Diagram 1 2 3 Photovoltaic

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 200-250 - 300 PurePulse CE S3 TM SG Series 160 PurePulse CE S3 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems 3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential

More information

EVO AT SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger

More information

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES RELIABLE SOLUTIONS in POWER ELECTRONICS RDAT SERIES Power Management Instruments BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES BATTERY CHARGER / DC RECTIFIER RDA / RDAT AUTOMATION

More information

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting

More information

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM Series 6 and 10 kva Tower On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set user

More information

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS RELIABLE SOLUTIONS in POWER ELECTRONICS Power Management Instruments DC Battery Charger / Automation Type Distributed by : nonstopower sdn bhd (822490-P) no. 78 & 80, jalan rimbunan raya, laman rimbunan,

More information

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...

More information

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc Haze Battery Company Ltd Sealed Lead Acid 6 & 12 Volt Monobloc AGM Range CONSTRUCTION - AGM battery construction is as shown in the diagram below. The positive and negative grids are cast from a calcium

More information

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification Conformity And Standard General safety requirements for UPS EMC requirements for UPS Table 1-1 Conformity and standard Normative reference

More information

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER Chassis Inverter power Rated input Rated output Battery pack Safeties Environment Others Input Voltage Lower Limit Input Voltage Upper Limit Power Input Current Output Voltage Output accuracy Transient

More information

CPS2000 Cabinet Power System

CPS2000 Cabinet Power System Input (Nominal): 90 Vac to 264 Vac (Autoranging) Output (Nominal): -48 Vdc (up to 28.8 A) and Optional 50 VA Ringing Generator The low-maintenance, outside-plant CPS2000 (Cabinet Power System) integrates

More information

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE DPP/DPP Digital Process INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE PROVIDING CONTINUITY OF ELECTRICAL POWER DPP/DPP DIGITAL PROCESS POWER Industrial Pulse Width Modulated

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

Illuminator Series CR NEMA 3R

Illuminator Series CR NEMA 3R Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the

More information

MTPi2000C - 80 KW (RANGE)

MTPi2000C - 80 KW (RANGE) MTPi2000C - 80 KW (RANGE) TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MTPi2000C - 80 kw system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipments with back up batteries.

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company imagination at work QUITO: Elia Liut N45-26 y Edmundo Chiriboga Telf:

More information

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ. 0-10V Dimmable FEATURES: AC Input 100~277VAC Built-in Active PFC Function Protection: SCP / OVP / OTP 24V Auxiliary Output 0-10V Dimming Control Dimming 1 ~ 100 Flicker Free High Operating Ambient Temp.:

More information

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V Sorensen XG Series / XTR Series 670 850 W 850 W, 1U Half Rack Programmable DC Power Supplies 6 600 V Highest Power Density Comprehensive Digital and Analog Interface Options Scalable, Multi-Unit Design

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT40K Highlights On-line double-conversion topology, VFI operation

More information

Haze Battery Company Ltd

Haze Battery Company Ltd Haze Battery Company Ltd Sealed Lead Acid 2 Volt Bloc Gelled Electrolyte Range CONSTRUCTION - Gel battery construction is as shown in the diagram. The positive and negative grids are cast from a calcium/tin

More information

AT SERIES EVO BATTERY CHARGER

AT SERIES EVO BATTERY CHARGER AT SERIES EVO BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T hindlepowerinc.com 610-330-9000 AT Series evo. A battery charger designed with YOU in mind. AT Series evo is HindlePower s next generation

More information

Technical data sheets

Technical data sheets GE Digital Energy Technical data sheets Digital Energy Uninterruptible Power Supply Series UPS 6-10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41

More information

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating ECP180 Series Low 1 Profile High Power Density 2.0 by 4.0 Footprint 120W Convection-cooled Rating 180W Force Cooled Rating Medical & ITE pprovals Class I and Class II pplications High Efficiency, up to

More information

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase Local Area Networks (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

FAT. FAT Battery Range FIAMM.COM

FAT. FAT Battery Range FIAMM.COM FAT FAT Battery Range FIAMM.COM FIAMM FAT RANGE OF VALVE REGULATED BATTERIES HAS BEEN DESIGNED FOR HIGH RELIABILITY AND SAFETY FRONT TERMINAL TELECOM INSTALLATIONS. MAIN APPLICATIONS: FAT BATTERY RANGE

More information

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw DELPHYS GP Green Power 2.0 range 160 to 1000 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

DC POWER SUPPLY SYSTEMS

DC POWER SUPPLY SYSTEMS DC POWER SUPPLY SYSTEMS double branch Rectifier - SCR type TITANIUM 2R-SCR PLUS SERIES TITANIUM 2R-SCR rectifier series belongs to the Double Branch category thus provided with two independent AC / DC

More information

KEPCO Will Point You In The Right Direction!

KEPCO Will Point You In The Right Direction! Looking For A High Power, Low Profile Power Supply? KEPCO Will Point You In The Right Direction! -9 AN ISO 900 COMPANY You'll Always Find What You Need At Kepco KLN Series Programmable Power Supply: 0W

More information

Security Plus Online Uninterruptible Power Supply

Security Plus Online Uninterruptible Power Supply Security Plus Online Uninterruptible Power Supply 1 2 GENERAL SAFETY INSTRUCTIONS Warnings in this manual appear in any of four ways: DANGER Danger- The danger symbol is a lightning bolt mark enclosed

More information