Thermodynamic Properties of DuPont ISCEON MO59 (R-417A)

Size: px
Start display at page:

Download "Thermodynamic Properties of DuPont ISCEON MO59 (R-417A)"

Transcription

1 DuPont ISCEON 9 Series REFRIGERANTS Technical Information Thermodynamic Properties of DuPont ISCEON MO59 (R-417A) SI Units

2

3 Thermodynamic Properties of DuPont ISCEON MO59 (R-417A) Refrigerant (R-125/R-134a/R /50/0/3.4% by weight) SI Units Tables of the thermodynamic properties of ISCEON MO59 (R-417A) have been developed and are presented here. This information is based on values calculated using the NIST REFPROP Database (McLinden, M.O., Klein, S.A., Lemmon, E.W., and Peskin, A.P., NIST Standard Reference Database 23, NIST thermodynamic and transport properties of refrigerants and refrigerant mixtures REFPROP version 7.0, Standard Reference Data Program, National Institute of Standards and Technology, 2005). Units P = Pressure in kpa (absolute) T = Temperature in Celsius V f = Fluid (liquid) specific volume in cubic Meters per kilogram V g = Vapour (gas) specific volume in cubic Meters per kilogram d f = Density of saturated vapour in kilograms per cubic meter d g = Density of saturated liquid in kilograms per cubic meter h = Enthalpy (kj/kg) s = Entropy (kj/kg. K) Reference points for Enthalpy and Entropy: h f = 200 kj/kg at 0 s f = 1 kj/kg. K at 0 Physical Properties Chemical Formula CHF 2 CF 3 /CH 2 FCF 3 /CH 3 CH 2 CH 2 CH 3 (46.6/50.0/3.4% by weight) Molecular mass Boiling Point At one atmosphere Critical Temperature Critical Pressure kpa 1

4 Table 1 DuPont ISCEON MO59 (R-417A) Saturation Properties Temperature Table PRESSURE (kpa) v f VOLUME (m 3 /kg) v g d f DENSITY (kg/m 3 ) d g h f ENTHALPY (kj/kg) LATENT h fg h g s f ENTROPY (kj/k kg) s g

5 Table 1 (continued) DuPont ISCEON MO59 (R-417A) Saturation Properties Temperature Table PRESSURE (kpa) v f VOLUME (m 3 /kg) v g d f DENSITY (kg/m 3 ) d g h f ENTHALPY (kj/kg) LATENT h fg h g s f ENTROPY (kj/k kg) s g

6 Table 1 (continued) DuPont ISCEON MO59 (R-417A) Saturation Properties Temperature Table PRESSURE (kpa) v f VOLUME (m 3 /kg) v g d f DENSITY (kg/m 3 ) d g h f ENTHALPY (kj/kg) LATENT h fg h g s f ENTROPY (kj/k kg) s g

7 Table 1 (continued) DuPont ISCEON MO59 (R-417A) Saturation Properties Temperature Table PRESSURE (kpa) v f VOLUME (m 3 /kg) v g d f DENSITY (kg/m 3 ) d g h f ENTHALPY (kj/kg) LATENT h fg h g s f ENTROPY (kj/k kg) s g

8 Table 2 DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) ( 73.05) ( 63.10) ( 56.68) ( 51.83) (1.5458) (325.8) (1.7154) (0.8071) (332.1) (1.6925) (0.5519) (336.2) (1.6805) (0.4215) (339.2) (1.6726) ( 47.87) ( 44.51) ( 41.57) ( 38.95) (0.3419) (341.7) (1.6668) (0.2881) (343.9) (1.6624) (0.2493) (345.7) (1.6588) (0.2199) (347.4) (1.6558)

9 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) ( 36.58) ( 34.40) ( 34.13) ( 32.39) V H S V H S V H S V H S (0.1968) (348.8) (1.6533) (0.1782) (350.2) (1.6511) (0.1760) (350.4) (1.6509) (0.1629) (351.5) (1.6493) ( 30.53) ( 28.77) ( 27.13) (_25.57) (0.1500) (352.6) (1.6476) (0.1391) (353.7) (1.6461) (0.1297) (354.7) (1.6448) (0.1215) (355.7) (1.6436)

10 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) ( 24.09) ( 22.68) ( ) ( 20.04) ( ) (356.6) ( ) (0.1078) (357.5) ( ) (0.1021) (358.3 ) ( ) (0.0970) (359.1) ( ) ( 18.80) ( 17.61) ( 16.46) ( 15.36) (0.0924) (359.8) (1.6390) (0.0882) (360.5) (1.6383) (0.0843) (361.2) (1.6376) (0.0808) (361.9) (1.637)

11 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) ( 14.28) ( 13.25) ( 12.24) ( 11.26) (0.0776) (362.5) (1.6364) (0.0746) (363.1) (1.6358) (0.0719) (363.7) (1.6353) (0.0693) (364.3) (1.6348) ( 10.31) ( 9.39) ( 8.49) ( 7.61) (0.0669) (364.9) (1.6343) (0.0647) (365.4) (1.6339) (0.0626) (365.9) (1.6335) (0.0606) (366.4) (1.6331)

12 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) ( 6.75) ( 5.92) ( 5.10) ( 4.30) V H S V H S V H S V H S (0.0588) (366.9) (1.6327) (0.0571) (367.4) (1.6324) (0.0555) (367.9) (1.632) (0.0539) (368.4) (1.6317) ( 3.52) (1.63) ( 2.01) ( 1.27) (0.0525) (368.8) (1.6314) (0.0517) (369.2) (1.6311) (0.0498) (369.7) (1.6308) (0.0485) (370.1) (1.6305)

13 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) ( 0.55) (1.19) (2.86) (4.46) (0.0470) (370.5) (1.6303) (0.0446) (371.5) (1.6297) (0.0422) (372.4) (1.6291) (0.0400) (373.3) (1.6286) (5.99) (7.47) (8.90) (10.28) (0.0380) (374.1) (1.6281) (0.0362) (374.9) (1.6277) (0.0346) (375.7) (1.6272) (0.0331) (376.4) (1.6268)

14 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) (10.28) (12.90) (14.16) (15.37) (0.0331) (376.4) (1.6268) (0.0304) (377.8) (1.6261) (0.0292) (378.5) (1.6258) (0.0281) (379.1) (1.6255) (16.56) (17.71) (18.84) (19.93) (0.0271) (379.7) (1.6252) (0.0262) (380.3) (1.6249) (0.0253) (380.8) (1.6246) (0.0244) (381.4) (1.6243)

15 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) (21.00) (23.07) (25.05) (26.94) (0.0237) (381.9) (1.624) (0.0222) (382.9) (1.6235) (0.0209) (383.8) (1.623) (0.0198) (384.7) (1.6225) (28.77) (32.22) (35.44) (38.47) (0.0187) (385.5) (1.6220) (0.0169) (387.0) (1.6210) (0.0154) (388.3) (1.6199) (0.0141) (389.4) (1.6189)

16 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) (41.32) (44.03) (46.60) (49.06) (0.0130) (390.4) (1.6178) (0.0120) (391.3) (1.6167) (0.0111) (392.1) (1.6155) (0.0104) (392.7) (1.6142) (51.40) (53.65) (55.81) (59.89) (0.0097) (393.3) (1.6128) (0.0091) (393.8) (1.6114) (0.0085) (394.1) (1.6098) (0.0075) (394.6) (1.6064)

17 Table 2 (continued) DuPont ISCEON MO59 (R-417A) Superheated Vapour Constant Pressure Tables V = Volume in m 3 /kg H = Enthalpy in kj/kg S = Entropy in kj/kg K (Saturation Properties in parentheses) (63.69) (67.25) (70.58) (73.72) (0.0067) (394.7) (1.6024) (0.0060) (394.4) (1.5978) (0.0053) (393.7) (1.5924) (0.0047) (392.4) (1.586) (76.69) (79.47) (82.09) V H S V H S V H S ( ) (390.6) (1.5781) (0.0037) (387.8) (1.5680) (0.0032) (383.6) (1.5540)

18 16

19

20 For Further Information: (800) DuPont Fluorochemicals Wilmington, DE Europe DuPont de Nemours International S.A. 2 Chemin du Pavillon P.O. Box 50 CH-1218 Le Grand-Saconnex Geneva, Switzerland Canada DuPont Canada, Inc. P.O. Box 2200, Streetsville Mississauga, Ontario Canada L5M 2H3 (905) DuPont México, S.A. de C.V. Homero 206 Col. Chapultepec Morales C.P México, D.F South America DuPont do Brasil S.A. Alameda Itapecuru, 506 Alphaville Barueri São Paulo, Brazil DuPont Argentina S.A. Casilla Correo 1888 Correo Central 1000 Buenos Aires, Argentina Asia Pacific Philippines DuPont Fareast Inc Philippines 19th floor Gt Tower International 6815 Ayala Avcorner Hv Costast Makati City Philippines Thailand DuPont (Thailand) Co.,Ltd 6-7th Floor, M. Thai Tower, All Seasons Place, 87 Wireless Road, Lumpini, Phatumwan Bangkok Thailand Lapee Thempongpattana thempongpattana.lapee@tha.dupont.com Malaysia DuPont Malaysia Sdn Bhd 6th Floor, Bangunan Samudera, No.1 Jalan Kontraktor U1/14 Sek U1, Hicom-Glenmarie Industrial Park Shah Alam Selangor Nicholas Leong Nicholas.Leong@mys.dupont.com Singapore DuPont Company (Singapore) Pte Ltd 1 HarbourFront Place #11-01 HarbourFront Tower One Singapore Shawn Wang / Jenny Chua shawn.wang@chn.dupont.com jenny.chua@sgp.dupont.com Indonesia PT DuPont Indonesia Menara Mulia 5th Floor Jl Jend. Gatot Subroto Kav Jakarta Indonesia Taiwan DuPont Taiwan Ltd. 13Fl., No. 167, Tun Hwa N. Rd., Taipei Taiwan, R. O. C Jackie Wu jackie.wu@twn.dupont.com India E I DuPont India Private Ltd DLF Cyber Greens, Tower C 7th Floor Sector 25A, DLF City Phase III Gurgaon INDIA Mr. Upal Roy Upal.Roy@ind.dupont.com in.dupont.com Korea DuPont(Korea) Inc. 4th Floor, Asia Tower #726, Yeoksam-dong, Kangnam-Ku Seoul, Korea Jae Young Park jae-young.park@kor.dupont.com Hong Kong DuPont China Limited 26/F., Tower 6, Gateway Canton Road Tsimsha tsui HongKong Tim Leung Tim-S.T.Leung@hkg.DuPont.com Australia/New Zealand DuPont (Australia) Ltd 168 Walker street North Sydney PO Box 930 North Sydney Sydney NSW John McCormack john.mccormack@aus.dupont.com China DuPont China Holding Co.,Ltd. 15th Floor, Shui On Plaza, 333 Huai Hai Road (Central) Shanghai Stacy Wang stacy.wang@chn.dupont.com Copyright 2005 DuPont or its affiliates. All rights reserved. The DuPont Oval Logo, DuPont, The miracles of science, and ISCEON, are registered trademarks or trademarks of E. I. du Pont de Nemours and Company or its affiliates. (1/06) RWJ353 Printed in U.S.A. Reorder No.: K-15291

Boiling Point at One Atmosphere C Critical Temperature 74.9 C

Boiling Point at One Atmosphere C Critical Temperature 74.9 C Opteon XP44 Refrigerant Thermodynamic Properties of Opteon XP44 (R-452A) SI Units Physical Properties Molecular Weight 103.5 g/mole Boiling Point at One Atmosphere -47.0 C Critical Temperature 74.9 C Critical

More information

Boiling Point at One Atmosphere C Critical Temperature 81.5 C

Boiling Point at One Atmosphere C Critical Temperature 81.5 C Opteon XP40 Refrigerant Thermodynamic Properties of Opteon XP40 (R-449A) SI Units Physical Properties Molecular Weight 87.2 g/mole Boiling Point at One Atmosphere -46.0 C Critical Temperature 81.5 C Critical

More information

Boiling Point at One Atmosphere C Critical Temperature 96.5 C

Boiling Point at One Atmosphere C Critical Temperature 96.5 C Opteon XP10 Refrigerant Thermodynamic Properties of Opteon XP10 (R-513A) SI Units Physical Properties Molecular Weight 108.4 g/mole Boiling Point at One Atmosphere -29.2 C Critical Temperature 96.5 C Critical

More information

Boiling Point at One Atmosphere 29.1 C Critical Temperature C. Critical Density kg/m 3

Boiling Point at One Atmosphere 29.1 C Critical Temperature C. Critical Density kg/m 3 Opteon XP30 Refrigerant Thermodynamic Properties of Opteon XP30 (R-514A) SI Units Physical Properties Molecular Weight 139.6 lb/lb-mole Boiling Point at One Atmosphere 29.1 C Critical erature 178.1 C Critical

More information

Thermodynamic Properties of DuPont ISCEON MO99

Thermodynamic Properties of DuPont ISCEON MO99 DuPont ISCEON REFRIGERANTS Technical Information Thermodynamic Properties of DuPont ISCEON MO99 SI Units Thermodynamic Properties of DuPont ISCEON MO99 SI Units Physical Properties Refrigerant Classification

More information

Thermodynamic Properties of

Thermodynamic Properties of DuPont Opteon yf REFRIGERANT Technical Information Thermodynamic Properties of DuPont Opteon yf SI Units Physical Properties Refrigerant Classification Molecular Weight HFO 114.04 g/mol Boiling Point at

More information

Thermodynamic Properties of Opteon XP40 (R-449A) Engineering (I/P) Units. Boiling Point at One Atmosphere F Critical Temperature 178.

Thermodynamic Properties of Opteon XP40 (R-449A) Engineering (I/P) Units. Boiling Point at One Atmosphere F Critical Temperature 178. Opteon XP40 Refrigerant Thermodynamic Properties of Opteon XP40 (R-449A) Engineering (I/P) Units Physical Properties Molecular Weight 87.2 lb/lb-mole Boiling Point at One Atmosphere -50.8 F Critical Temperature

More information

Boiling Point at One Atmosphere F Critical Temperature F

Boiling Point at One Atmosphere F Critical Temperature F Opteon XP44 Refrigerant Thermodynamic Properties of Opteon XP44 (R-452A) Engineering (I/P) Units Physical Properties Molecular Weight 103.5 lb/lb-mole Boiling Point at One Atmosphere -52.7 F Critical Temperature

More information

Opteon XP40. Thermodynamic Properties

Opteon XP40. Thermodynamic Properties Thermodynamic Properties This bulletin presents thermodynamic data for (R-449A), a non-flammable, low GWP hydrofluoro-olefin based refrigerant. (R-449A) is a near azeotrope blend of HFC-32/HFC-125/HFO-1234yf/HFC-134a.

More information

HCFC-123. Thermodynamic Properties of. (2,2 dichloro-1,1,1-trifluoroethane) T-123 ENG. Technical Information

HCFC-123. Thermodynamic Properties of. (2,2 dichloro-1,1,1-trifluoroethane) T-123 ENG. Technical Information Technical Information D U P O N T T-123 ENG SUVA REFRIGERANTS TM Thermodynamic Properties of HCFC-123 (2,2 dichloro-1,1,1-trifluoroethane) Du Pont Product Names: SUVA 123 Refrigerant f Thermodynamic Properties

More information

Technical Information. T-HP62 SI f. Suva refrigerants. Thermodynamic Properties of Suva HP62. Refrigerant [R-404A (44/52/4]

Technical Information. T-HP62 SI f. Suva refrigerants. Thermodynamic Properties of Suva HP62. Refrigerant [R-404A (44/52/4] Technical Information T-HP62 SI f Suva refrigerants Thermodynamic Properties of Suva HP62 Refrigerant [R-404A (44/52/4] Thermodynamic Properties of SUVA HP62 Refrigerant SI Units New tables of the thermodynamic

More information

Thermodynamic Properties of SUVA MP66 Refrigerant (R-401B) Technical Information T-MP66- SI. DuPont Fluorochemicals

Thermodynamic Properties of SUVA MP66 Refrigerant (R-401B) Technical Information T-MP66- SI. DuPont Fluorochemicals DuPont Fluorochemicals Technical Information T-MP66- SI Technical Information Technical Information Thermodynamic Properties of SUVA MP66 Refrigerant (R-401B) Thermodynamic Properties of Suva MP66 Refrigerant

More information

Theoretical and Experimental Study of an Oil-Free Scroll Vapor Expander

Theoretical and Experimental Study of an Oil-Free Scroll Vapor Expander Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Theoretical and Experimental Study of an Oil-Free Scroll Vapor Expander Bernard Aoun

More information

TEST REPORT #18. Compressor Calorimeter Test of Refrigerants R-134a, N-13a and ARM-42a

TEST REPORT #18. Compressor Calorimeter Test of Refrigerants R-134a, N-13a and ARM-42a Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #18 Compressor Calorimeter Test of Refrigerants R-134a, N-13a

More information

GYANMANJARI INSTITUTE OF TECHNOLOGY (GMIT) SUBJECT: ELEMENTS OF MECHANICAL ENGINEERING Assignment Ch 1

GYANMANJARI INSTITUTE OF TECHNOLOGY (GMIT) SUBJECT: ELEMENTS OF MECHANICAL ENGINEERING Assignment Ch 1 1. 3. GYANMANJARI INSTITUTE OF TECHNOLOGY (GMIT) Assignment Ch 1 A steel ball having mass of 10 kg and a specific heat of 460 J/kg K is heated from 50 o C to 200 o C. Determine the heat required. In a

More information

AHRI Standard 1371 (SI) 2017 Standard for Performance Rating of Electronic Expansion Valves

AHRI Standard 1371 (SI) 2017 Standard for Performance Rating of Electronic Expansion Valves AHRI Standard 1371 (SI) 2017 Standard for Performance Rating of Electronic Expansion Valves IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of

More information

Noble Group of Institutions, Junagadh. Faculty of Engineering Department of Mechanical Engineering

Noble Group of Institutions, Junagadh. Faculty of Engineering Department of Mechanical Engineering Semester:1 st Subject: Elements of Mechanical Engineering (2110006) Faculty: Mr. Ishan Bhatt Year: 2017-18 Class: Comp. & IT Ele TUTORIAL 1 INTRODUCTION Q.1 Define: Force, Work, Pressure, Energy, Heat

More information

VETRI VINAYAHA COLLEGE OF ENGINEERING AND TECHNOLOGY DEPARTMENT OF MECHANICAL ENGINEERING ME6404 THERMAL ENGINEERING

VETRI VINAYAHA COLLEGE OF ENGINEERING AND TECHNOLOGY DEPARTMENT OF MECHANICAL ENGINEERING ME6404 THERMAL ENGINEERING VETRI VINAYAHA COLLEGE OF ENGINEERING AND TECHNOLOGY DEPARTMENT OF MECHANICAL ENGINEERING ME6404 THERMAL ENGINEERING UNIT I - GAS POWER CYCLES 1. What is a thermodynamic cycle? Thermodynamic cycle is defined

More information

Air Cylinders Drive System Full Stroke Time & Stroke End Velocity. How to Read the Graph

Air Cylinders Drive System Full Stroke Time & Stroke End Velocity. How to Read the Graph 1-1 Best Pneumatics Air Cylinders Drive System Full Time & End Velocity How to Read the Graph This graph shows the full stroke time and stroke end velocity when a cylinder drive system is composed of the

More information

Hours / 100 Marks Seat No.

Hours / 100 Marks Seat No. 17529 14115 3 Hours / 100 Seat No. Instructions (1) All Questions are Compulsory. (2) Answer each next main Question on a new page. (3) Illustrate your answers with neat sketches wherever necessary. (4)

More information

International Conference on Advances in Energy, Environment and Chemical Engineering (AEECE-2015)

International Conference on Advances in Energy, Environment and Chemical Engineering (AEECE-2015) International Conference on Advances in Energy, Environment and Chemical Engineering (AEECE-2015) Supercritical CO2 Cycle System Optimization of Marine Diesel Engine Waste Heat Recovery Shengya Hou 1,

More information

ME2301 THERMAL ENGINEERING L T P C OBJECTIVE:

ME2301 THERMAL ENGINEERING L T P C OBJECTIVE: ME2301 THERMAL ENGINEERING L T P C 3 1 0 4 OBJECTIVE: To integrate the concepts, laws and methodologies from the first course in thermo dynamics into analysis of cyclic processes To apply the thermodynamic

More information

TEST REPORT #29. Compressor Calorimeter Test of R- 404A Alternative Refrigerant DR-7 in Reciprocating Compressors

TEST REPORT #29. Compressor Calorimeter Test of R- 404A Alternative Refrigerant DR-7 in Reciprocating Compressors Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #29 Compressor Calorimeter Test of R- 4A Alternative Refrigerant

More information

EME MCQ QUESTION BANK

EME MCQ QUESTION BANK EME MCQ QUESTION BANK 1. Work is considered positive when a) Work is done on the system b) work is done by the system c) both a and b d) none of the above 2. A source of energy is known as renewable source

More information

TEST REPORT #50. Compressor Calorimeter Test of Refrigerant Blend DR-3 in a R-404A Reciprocating Compressor

TEST REPORT #50. Compressor Calorimeter Test of Refrigerant Blend DR-3 in a R-404A Reciprocating Compressor Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT # Compressor Calorimeter Test of Refrigerant Blend DR-3 in a

More information

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING. Question Bank. UNIT-I THERMODYNAMIC CYCLES Part-A (2 Marks)

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING. Question Bank. UNIT-I THERMODYNAMIC CYCLES Part-A (2 Marks) KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING Question Bank Sub. Code/Name: ME1351 - THERMAL ENGINEERING Year/Sem: III/VI 1. What is a thermodynamic cycle? UNIT-I THERMODYNAMIC CYCLES

More information

Low NOx Combustion of DME by Exhaust Gas Recirculation under the High Pressure

Low NOx Combustion of DME by Exhaust Gas Recirculation under the High Pressure 35 7 th Asia DME Conference November 16-18, 011 Niigata Toki Messe Convention Center, Niigata, Japan Low Combustion of DME by Exhaust Gas Recirculation under the High Pressure *Hiroaki TAKEUCHI Mamoru

More information

THERMINOL LT. heat transfer fluid. Wide temperature range, liquid/vapor phase fluid to 315 C. (--103 to 600 F)

THERMINOL LT. heat transfer fluid. Wide temperature range, liquid/vapor phase fluid to 315 C. (--103 to 600 F) THERMINOL LT heat transfer fluid Wide temperature range, liquid/vapor phase fluid --75 to 315 C (--103 to 600 F) THERMINOL LT heat transfer fluid Normal boiling pt. temp., 358 Max. bulk use temp., 600

More information

Calculation of Kv value Medium Saturated Liquids steam RECOMMENDED FLOW VELOCITIES AT THE INLET OF VALVE, FOR THE SIZING OF NOMINAL PIPE SIZE :

Calculation of Kv value Medium Saturated Liquids steam RECOMMENDED FLOW VELOCITIES AT THE INLET OF VALVE, FOR THE SIZING OF NOMINAL PIPE SIZE : DT SHEET FOR CONTROL VLVES VLVE SIZING The valve sizing is based on the calculation of the Kv coefficient. The Kv represents the quantity of water, expressed in cubic meters (m3) at 15ºC, that flows through

More information

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid

More information

Elements of Mechanical Engineering (EME) QUESTIONS

Elements of Mechanical Engineering (EME) QUESTIONS QUESTIONS 1) In First angle projection method (a) Plan comes above elevation (b) Plan comes below elevation (c) Plan comes besides elevation (d) Plan is on the left hand side. (2) Where LHSV in third angle

More information

05 Marks (c) Sketch and explain Lancashire Boiler.

05 Marks (c) Sketch and explain Lancashire Boiler. Model question paper No.1 1. Answer any FIVE full questions choosing at least two questions from part A & two questions from part B 2. Use of steam tables is permitted 1. (a) Discuss briefly the different

More information

THERMINOL 62. heat transfer fluid. High performance under low-pressure applications. -23 to 325 C. (--9 to 620 F)

THERMINOL 62. heat transfer fluid. High performance under low-pressure applications. -23 to 325 C. (--9 to 620 F) THERMINOL 62 heat transfer fluid High performance under low-pressure applications -23 to 325 C (--9 to 620 F) THERMINOL 62 heat transfer fluid Min. use temp., 9 Max. bulk use temp., 620 Physical and chemical

More information

Capacity Charts. Direct Spring Acting Safety Relief Valves for Air, Gas, Liquid, and Steam Service

Capacity Charts. Direct Spring Acting Safety Relief Valves for Air, Gas, Liquid, and Steam Service Direct Spring Acting Safety Relief Valves for Air, Gas, Liquid, and Steam Service About Reyco Valve Division The Reyco line of direct spring acting pressure relief valves utilizes sound engineering principles

More information

Klea 410A Engineers Tables SI Units

Klea 410A Engineers Tables SI Units Klea 410A Engineers Tables SI Units 1. Introduction The following tables provide practical information to help you design or set up refrigeration systems using Klea 410A. We've tried to make the layout

More information

Air Cylinders Drive System Full Stroke Time & Stroke End Velocity. How to Read the Graph

Air Cylinders Drive System Full Stroke Time & Stroke End Velocity. How to Read the Graph 1 Best Pneumatics Air Cylinders Drive System Full Time & End Velocity How to Read the Graph This graph shows the full stroke time and stroke end velocity when a cylinder drive system is composed of the

More information

THERMINOL 55. heat transfer fluid. Efficient, reliable mediumtemperature-range. -28 to 290 C. (--18 to 550 F)

THERMINOL 55. heat transfer fluid. Efficient, reliable mediumtemperature-range. -28 to 290 C. (--18 to 550 F) THERMINOL 55 heat transfer fluid Efficient, reliable mediumtemperature-range fluid -28 to 290 C (--18 to 550 F) THERMINOL 55 heat transfer fluid Max. extended use temp, 600 Max. bulk use temp., 550 Physical

More information

Liquefied Petroleum Gas. Liquefied. Petroleum Gas. Product Reference Manual - Section 5 - Liquefied Petroleum Gas

Liquefied Petroleum Gas. Liquefied. Petroleum Gas. Product Reference Manual - Section 5 - Liquefied Petroleum Gas Liquefied Petroleum Product Reference Manual - Section - 1 LPG 2 - Handigas 6 - Handipack 7 - Forklift (Autogas) 8 - Propane (C 3 H 8 ) 8 - Handigas Dumpy (Mini Bulk) 9 - Handigas Bulk 9 - Propane Bulk

More information

CAMERON HYDRAULIC DATA

CAMERON HYDRAULIC DATA CAMERON HYDRAULIC DATA Preface to the Twentieth Edition The Book is a Flowserve Corporation publication and, as in the previous nineteen editions, is published as an aid to engineers involved with the

More information

SAFE - ANSI / -TC / -TCP / -TCS

SAFE - ANSI / -TC / -TCP / -TCS SAFE - ANSI / -TC / -TCP / -TCS Safety valves Angle pattern safety valve 1 to 6 ARI-SAFE-ANSI ASME Code Section VIII-Division 1. UV-stamp NB-stamp Type-test approved acc. to TRD and AD2000-A2 Direct loaded

More information

THERMINOL 54. heat transfer fluid. Efficient, reliable mediumtemperature-range. 28 to 280 C. (- 18 to 540 F)

THERMINOL 54. heat transfer fluid. Efficient, reliable mediumtemperature-range. 28 to 280 C. (- 18 to 540 F) THERMINOL 54 heat transfer fluid Efficient, reliable mediumtemperature-range fluid 28 to 280 C (- 18 to 540 F) THERMINOL 54 heat transfer fluid Max. bulk use temp., 540 Physical and chemical characteristics

More information

Retrofit Guidelines for DuPont ISCEON MO79 (R-422A) Refrigerant

Retrofit Guidelines for DuPont ISCEON MO79 (R-422A) Refrigerant DuPont ISCEON 9 Series REFRIGERANTS Technical Information ART- 44 (MO79-EU) Retrofit Guidelines for DuPont ISCEON MO79 (R-422A) Refrigerant Retrofit Guidelines for DuPont ISCEON MO79 Refrigerant Table

More information

DEPARTMENT OF MECHANICAL ENGINEERING Question Bank ME THERMAL ENGINEERING. Part-A (2 Marks)

DEPARTMENT OF MECHANICAL ENGINEERING Question Bank ME THERMAL ENGINEERING. Part-A (2 Marks) DEPARTMENT OF MECHANICAL ENGINEERING Question Bank ME1351 - THERMAL ENGINEERING UNIT I GAS POWER CYCLES Part-A (2 Marks) 1. What is a thermodynamic cycle? 2. What is meant by air standard cycle? 3.. Name

More information

The performance of diesel engine using diesel oil and dme mixture fuels

The performance of diesel engine using diesel oil and dme mixture fuels International Research Journal on Engineering Vol. 2(2), pp. 019-027, February, 2014 Available online at http://www.apexjournal.org 2014 Apex Journal International Full Length Research The performance

More information

TEST REPORT #49. Compressor Calorimeter Test of Refrigerant Blend HDR110 in a R-404A Reciprocating Compressor

TEST REPORT #49. Compressor Calorimeter Test of Refrigerant Blend HDR110 in a R-404A Reciprocating Compressor Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #49 Compressor Calorimeter Test of Refrigerant Blend HDR110

More information

Supercritical Organic Rankine Cycle yields useful power and emissions benefits

Supercritical Organic Rankine Cycle yields useful power and emissions benefits Supercritical Organic Rankine Cycle yields useful power and emissions benefits John Buckingham, CEng FIMechE BMT Defence Services Limited, UK Sean McCracken, Granite Power Limited, Australia SYNOPSIS The

More information

Interstate Chemical Company Hermitage, PA INTERCOOL BIO-GREEN A NEW FULLY INHIBITED HEAT TRANSFER FLUID MADE FROM A RENEWABLE ENERGY SOURCE

Interstate Chemical Company Hermitage, PA INTERCOOL BIO-GREEN A NEW FULLY INHIBITED HEAT TRANSFER FLUID MADE FROM A RENEWABLE ENERGY SOURCE Interstate Chemical Company Hermitage, PA INTERCOOL BIO-GREEN A NEW FULLY INHIBITED HEAT TRANSFER FLUID MADE FROM A RENEWABLE ENERGY SOURCE INTERCOOL BIO-GREEN A A Green Heat Transfer Fluid Intercool Bio-Green

More information

DEPARTMENT OF MECHANICAL ENGINEERING ME ENGINEERING THERMODYNAMICS TWO MARKS QUESTION AND ANSWER

DEPARTMENT OF MECHANICAL ENGINEERING ME ENGINEERING THERMODYNAMICS TWO MARKS QUESTION AND ANSWER DEPARTMENT OF MECHANICAL ENGINEERING ME 6301- ENGINEERING THERMODYNAMICS TWO MARKS QUESTION AND ANSWER 1. Define the term thermal engineering. Ans: Thermal engineering is the science that deals with the

More information

2.61 Internal Combustion Engine Final Examination. Open book. Note that Problems 1 &2 carry 20 points each; Problems 3 &4 carry 10 points each.

2.61 Internal Combustion Engine Final Examination. Open book. Note that Problems 1 &2 carry 20 points each; Problems 3 &4 carry 10 points each. 2.61 Internal Combustion Engine Final Examination Open book. Note that Problems 1 &2 carry 20 points each; Problems 3 &4 carry 10 points each. Problem 1 (20 points) Ethanol has been introduced as the bio-fuel

More information

CHEMISTRY 135. Biodiesel Production and Analysis

CHEMISTRY 135. Biodiesel Production and Analysis CHEMISTRY 135 General Chemistry II Biodiesel Production and Analysis The energy content of biodiesel can be roughly estimated with a simple laboratory apparatus. What features of biodiesel make it an attractive

More information

(a) then mean effective pressure and the indicated power for each end ; (b) the total indicated power : [16]

(a) then mean effective pressure and the indicated power for each end ; (b) the total indicated power : [16] Code No: R05220304 Set No. 1 II B.Tech II Semester Regular Examinations, Apr/May 2007 THERMAL ENGINEERING-I ( Common to Mechanical Engineering and Automobile Engineering) Time: 3 hours Max Marks: 80 Answer

More information

MEB THERMAL ENGINEERING - I QUESTION BANK UNIT-I PART-A

MEB THERMAL ENGINEERING - I QUESTION BANK UNIT-I PART-A MEB 420 - THERMAL ENGINEERING - I QUESTION BANK UNIT-I Each question carries 1 mark. PART-A 1. Define temperature. 2. Define intensive property 3. Explain the term absolute zero of temperature 4. State

More information

THERMINOL 66. heat transfer fluid. Proven performance for high-temperature, low-pressure applications. -3 to 345 C. (27 to 650 F)

THERMINOL 66. heat transfer fluid. Proven performance for high-temperature, low-pressure applications. -3 to 345 C. (27 to 650 F) THERMINOL 66 heat transfer fluid Proven performance for high-temperature, low-pressure applications -3 to 345 C (27 to 650 F) THERMINOL 66 heat transfer fluid Min. use temp., 27 Max. bulk use temp., 650

More information

THERMINOL 75. heat transfer fluid. Ultrahigh temperature at low pressure. 80 to 385 C. (175 to 725 F)

THERMINOL 75. heat transfer fluid. Ultrahigh temperature at low pressure. 80 to 385 C. (175 to 725 F) THERMINOL 75 heat transfer fluid Ultrahigh temperature at low pressure 80 to 385 C (175 to 725 F) THERMINOL 75 heat transfer fluid Max. bulk use temp., 725 Physical and chemical characteristics Min. use

More information

KTM V-PORT CONTROL BALL VALVE FULL BORE AND REDUCED BORE

KTM V-PORT CONTROL BALL VALVE FULL BORE AND REDUCED BORE A rugged, long-life V-port control ball valve with excellent flow characteristics for various fluids including slurries and fibers FEATURES GENERAL APPLICATION Steam, liquids, gas or critical services

More information

Analysis of a Waste Heat Recovery System for a Gas Engine

Analysis of a Waste Heat Recovery System for a Gas Engine International Conference on Industrial Technology and Management Science (ITMS 2015) Analysis of a Waste Heat Recovery System for a Gas Engine Chen Bo North University of China, Taiyuan, China, 030051

More information

Honeywell Solstice yf Cool for all concerned

Honeywell Solstice yf Cool for all concerned Honeywell olstice yf Cool for all concerned HONEYWELL LOW GLOBAL WARMING POTENTIAL REFRIGERANT I THE COOL CHOICE olstice yf A Green olution to a Global Challenge Introduction tarting in 2011, automakers

More information

VXF53.. VVF53.. Acvatix Valves VVF..,VXF.. Basic Documentation. CE1P4030en Building Technologies

VXF53.. VVF53.. Acvatix Valves VVF..,VXF.. Basic Documentation. CE1P4030en Building Technologies VVF53.. VXF53.. Acvatix Valves VVF..,VXF.. Basic Documentation CE1P4030en 12.09.2011 Building Technologies Siemens Switzerland Ltd. Industry Sector Building Technologies Division Gubelstrasse 22 6301 Zug

More information

SIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR (AUTONOMOUS) QUESTION BANK UNIT I I.C ENGINES

SIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR (AUTONOMOUS) QUESTION BANK UNIT I I.C ENGINES SIDDHARTH INSTITUTE OF ENGINEERING & TECHNOLOGY :: PUTTUR UNIT I I.C ENGINES 1 (a) Explain any six types of classification of Internal Combustion engines. (6M) (b) With a neat sketch explain any three

More information

STEAM-ENGINE AND PROFESSOR OF MECHANISM AND APPLIED MECHANICS IN THE UNIVERSITY OF CAMBRIDGE. CAMBRIDGE: AT THE UNIVERSITY PRESS.

STEAM-ENGINE AND PROFESSOR OF MECHANISM AND APPLIED MECHANICS IN THE UNIVERSITY OF CAMBRIDGE. CAMBRIDGE: AT THE UNIVERSITY PRESS. THE STEAM-ENGINE AND OTHEE HEAT-ENGINES BY J. A. EWING, M.A., B.Sc, F.E.S., M.INST.C.E., PROFESSOR OF MECHANISM AND APPLIED MECHANICS IN THE UNIVERSITY OF CAMBRIDGE. CAMBRIDGE: AT THE UNIVERSITY PRESS.

More information

Effect of Lubricant-Refrigerant Mixture Properties on Compressor Efficiencies

Effect of Lubricant-Refrigerant Mixture Properties on Compressor Efficiencies Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 Effect of Lubricant-Refrigerant Mixture Properties on Compressor Efficiencies Scott

More information

Prediction of Physical Properties and Cetane Number of Diesel Fuels and the Effect of Aromatic Hydrocarbons on These Entities

Prediction of Physical Properties and Cetane Number of Diesel Fuels and the Effect of Aromatic Hydrocarbons on These Entities [Regular Paper] Prediction of Physical Properties and Cetane Number of Diesel Fuels and the Effect of Aromatic Hydrocarbons on These Entities (Received March 13, 1995) The gross heat of combustion and

More information

Please welcome for any correction or misprint in the entire manuscript and your valuable suggestions kindly mail us

Please welcome for any correction or misprint in the entire manuscript and your valuable suggestions kindly mail us Problems of Practices Of Basic and Applied Thermodynamics I. C. Engine Prepared By Brij Bhooshan Asst. Professor B. S. A. College of Engg. And Technology Mathura, Uttar Pradesh, (India) Supported By: Purvi

More information

Effect of Fuel, Compression ratios on Energetic and Exergetic efficiency of Spark Ignition (SI) Engine

Effect of Fuel, Compression ratios on Energetic and Exergetic efficiency of Spark Ignition (SI) Engine , July 4-6, 12, London, U.K. Effect of Fuel, s on Energetic and Exergetic efficiency of Spark Ignition (SI) Engine Munawar Nawab Karimi *, Sandeep Kumar Kamboj Abstract - In this study, the effect of the

More information

Biodiesel Production and Analysis

Biodiesel Production and Analysis Biodiesel Production and Analysis Introduction A key current focus in science and engineering is the development of technologies for generating and utilizing new sources of energy. Climate change, geopolitics,

More information

A HIGH PERFORMANCE LINEAR COMPRESSOR FOR CPU COOLING

A HIGH PERFORMANCE LINEAR COMPRESSOR FOR CPU COOLING Presented at the 16 th International Compressor Engineering Conference at Purdue. C23-3 A HIGH PERFORMANCE LINEAR COMPRESSOR FOR CPU COOLING Reuven Unger Shlomo Novotny Sunpower, Inc. Sun Microsystems

More information

THERMINOL RD. heat transfer fluid. Low-viscosity, medium-temperature fluid. -36 to 270 C. (--33 to 520 F)

THERMINOL RD. heat transfer fluid. Low-viscosity, medium-temperature fluid. -36 to 270 C. (--33 to 520 F) THERMINOL RD heat transfer fluid Low-viscosity, medium-temperature fluid -36 to 270 C (--33 to 520 F) THERMINOL RD heat transfer fluid Max. bulk use temp., 520 Physical and chemical characteristics Min.

More information

THERMINOL 68. heat transfer fluid. High-temperature, low-viscosity fluid. -26 to 360 C. ( 14 to 680 F)

THERMINOL 68. heat transfer fluid. High-temperature, low-viscosity fluid. -26 to 360 C. ( 14 to 680 F) THERMINOL 68 heat transfer fluid High-temperature, low-viscosity fluid -26 to 360 C ( 14 to 680 F) THERMINOL 68 heat transfer fluid Physical and chemical characteristics Therminol 68 fluid is designed

More information

Refrigerating Engineers & Technicians Association. Industrial Refrigeration 1 Final Examination for Course Credit Supplemental Materials Package

Refrigerating Engineers & Technicians Association. Industrial Refrigeration 1 Final Examination for Course Credit Supplemental Materials Package Refrigerating Engineers & Technicians Association Industrial Refrigeration 1 Final Examination for Course Credit Supplemental Materials Package - June 1, 2007-1 Commonly Used Refrigerants Refrigerant Number

More information

-5 F to 620 F. High Performance, Low-pressure Heat Transfer Fluid. Heat Transfer Fluid by Solutia. Technical Bulletin A +400 C +700 F +350 C

-5 F to 620 F. High Performance, Low-pressure Heat Transfer Fluid. Heat Transfer Fluid by Solutia. Technical Bulletin A +400 C +700 F +350 C 62 High Performance, Low-pressure Heat Transfer Fluid Heat Transfer Fluid by Solutia Technical Bulletin 7239731A 62-5 F to 620 F +400 C +350 C +300 C +250 C +200 C +150 C +100 C +50 C 0 C +700 F +600 F

More information

Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment

Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment AHRI Standard 1060 (I-P) 2011 Standard for Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does

More information

THERMINOL VP-3. heat transfer fluid. High-temperature, low-odor, vapor/liquid phase fluid. 2 to 330 C. (36 to 625 F)

THERMINOL VP-3. heat transfer fluid. High-temperature, low-odor, vapor/liquid phase fluid. 2 to 330 C. (36 to 625 F) THERMINOL VP-3 heat transfer fluid High-temperature, low-odor, vapor/liquid phase fluid 2 to 330 C (36 to 625 F) THERMINOL VP-3 heat transfer fluid Physical and chemical characteristics Therminol VP-3

More information

THERMINOL 72. heat transfer fluid. High temperature, excellent stability at medium pressure. -14 to 380 C. (7 to 715 F)

THERMINOL 72. heat transfer fluid. High temperature, excellent stability at medium pressure. -14 to 380 C. (7 to 715 F) THERMINOL 72 heat transfer fluid High temperature, excellent stability at medium pressure -14 to 380 C (7 to 715 F) THERMINOL 72 heat transfer fluid 225 Min. use temp., 7 800 Max. bulk use temp., 715 F

More information

Numerical Study on the Combustion and Emission Characteristics of Different Biodiesel Fuel Feedstocks and Blends Using OpenFOAM

Numerical Study on the Combustion and Emission Characteristics of Different Biodiesel Fuel Feedstocks and Blends Using OpenFOAM Numerical Study on the Combustion and Emission Characteristics of Different Biodiesel Fuel Feedstocks and Blends Using OpenFOAM Harun M. Ismail 1, Xinwei Cheng 1, Hoon Kiat Ng 1, Suyin Gan 1 and Tommaso

More information

HEAT EXCHANGER OVERVIEW

HEAT EXCHANGER OVERVIEW HEAT EXCHANGERS 1 PURPOSE A heat exchanger is an apparatus performing heat exchange between two or several fluids. It can carry out this task by: Segregating the fluids and making them exchange heat through

More information

CROSBY STYLE JB PRESSURE RELIEF VALVE

CROSBY STYLE JB PRESSURE RELIEF VALVE A large orifice pressure relief valve engineered to provide high quality, dependable overpressure protection for air, gas, vapor and steam applications FEATURES Ten size product range is the broadest available.

More information

Eliminator Liquid line filter driers, type DCL and DML

Eliminator Liquid line filter driers, type DCL and DML Eliminator Liquid line filter driers, type DCL and DML Flare connection Solder connection (copper) REFRIGERATION AND AIR CONDITIONING Technical leaflet Eliminator Liquid line filter driers, type DCL and

More information

Engineers Tables SI Units

Engineers Tables SI Units Engineers Tables SI Units 1. Introduction The following tables provide practical information to help you design or set up refrigeration systems using KLEA 407C. We've tried to make the layout as easy as

More information

Density Baume (% m/m) (kg/m 3 ) (lb/ft 3 ) (lb/ga) (degree) % (m/m) (kg/m 3 ) (lb/ft 3 ) (lb/ga) (degree)

Density Baume (% m/m) (kg/m 3 ) (lb/ft 3 ) (lb/ga) (degree) % (m/m) (kg/m 3 ) (lb/ft 3 ) (lb/ga) (degree) Appendix 779 List of Tables Table A.1 Density and Baume of Pure Sucrose Solutions Table A.2 Sucrose Solubility in Pure Sucrose Solutions Table A.3 Sucrose Solubility in Impure Sucrose Solutions Table A.4

More information

Blum Aventos HS User Guide.

Blum Aventos HS User Guide. Blum Aventos HS User Guide. Introduction Overview The Blum Aventos HS Package from Solid Setup adds the Blum Aventos HS door Lift system to Cabinet Vision Solid and optional Servo drive. It provides drilling

More information

TEST REPORT #67. Compressor Calorimeter Test of Refrigerant ARM-25 in a R-404A Reciprocating Compressors

TEST REPORT #67. Compressor Calorimeter Test of Refrigerant ARM-25 in a R-404A Reciprocating Compressors Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #67 Compressor Calorimeter Test of Refrigerant ARM-25 in a R-404A

More information

Catalogue Refrigeration. Air conditioning. Heating. Renewable Energy

Catalogue Refrigeration. Air conditioning. Heating. Renewable Energy Catalogue 2011 Refrigeration. Air conditioning. Heating. Renewable Energy Dehon Group commitment Listen & Satisfy Our customers by taking care of their needs and by continuously improving our products

More information

Assignment-1 Introduction

Assignment-1 Introduction Assignment-1 Introduction 1. Compare S.I. engines with C.I engines. 2. Explain with the help of neat sketch, the working of a 2-stroke petrol engine. 3. Derive an equation of efficiency, work output and

More information

Performance and Operating Characteristics of a Novel Positive-Displacement Oil-Free CO2 Compressor

Performance and Operating Characteristics of a Novel Positive-Displacement Oil-Free CO2 Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 Performance and Operating Characteristics of a Novel Positive-Displacement Oil-Free

More information

A Guide to Conversions & Use of Railroad Tracks + Practice Set

A Guide to Conversions & Use of Railroad Tracks + Practice Set A Guide to Conversions & Use of Railroad Tracks + Practice Set Conversion FAQs Which unit is one? All conversion factors have two numbers and two units. One of the numbers is usually ONE and the other

More information

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS FUELS AND EFFECTS ON ENGINE EMISSIONS The Lecture Contains: Transport Fuels and Quality Requirements Fuel Hydrocarbons and Other Components Paraffins Cycloparaffins Olefins Aromatics Alcohols and Ethers

More information

Heat Exchanger Design

Heat Exchanger Design CH2407 Process Equipment Design II Heat Exchanger Design Dr. M. Subramanian Associate Professor Department of Chemical Engineering Sri Sivasubramaniya Nadar College of Engineering Kalavakkam 603 110, Kanchipuram

More information

SAFE - ANSI. Angle pattern safety valve 1 to 6 (DN 25 to 150) Safety valves ARI-SAFE-ANSI

SAFE - ANSI. Angle pattern safety valve 1 to 6 (DN 25 to 150) Safety valves ARI-SAFE-ANSI SAFE - ANSI Safety valves Angle pattern safety valve 1 to 6 (DN 25 to 150) ARI-SAFE-ANSI ASME Code Section VIII-Division 1. UV-stamp NB-stamp Type-test approved acc. to TRD and AD2000-A2 Direct loaded

More information

USO4CICV01/US04CICH02:

USO4CICV01/US04CICH02: Natubhai V. Patel College of Pure & Applied Sciences S. Y. B.Sc. Semester-4 Industrial chemistry/ IC (Vocational) USO4CICV0/US04CICH02: Chemical Plant Utilities UNIT 5 Internal combustion engine In an

More information

Specialties in Steam Flow Measurement

Specialties in Steam Flow Measurement Specialties in Steam Flow Measurement Flow Measurement in: Wet Steam: Only with severe limitations Water content cannot be measured from pressure and temperature because: Water content x is NO function

More information

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad INSTITUTE OF ERONUTIL ENGINEERING (utonomous) Dundigal, Hyderabad -500 043 MEHNIL ENGINEERING QUESTION BNK ourse Name : THERML ENGINEERING-I ourse ode : 40313 lass : II B. Tech II Semester Branch : Mechanical

More information

HYDROFLUORIC ACID FLUOROCARBONS AND PROCESS ECONOMICS PROGRAM. Report No. 89. November A private report by the MENLO PARK, CALIFORNIA

HYDROFLUORIC ACID FLUOROCARBONS AND PROCESS ECONOMICS PROGRAM. Report No. 89. November A private report by the MENLO PARK, CALIFORNIA Report No. 89 HYDROFLUORIC ACID FLUOROCARBONS AND by HAROLD W. SCHEELINE November 1973 A private report by the PROCESS ECONOMICS PROGRAM STANFORD RESEARCH INSTITUTE I I MENLO PARK, CALIFORNIA -. _ CONTENTS

More information

PERFORMANCE AND EMISSION CHARACTERISTICS OF A VARIABLE COMPRESSION SI ENGINE USING ETHANOL- GASOLINE BLENDS AS FUEL

PERFORMANCE AND EMISSION CHARACTERISTICS OF A VARIABLE COMPRESSION SI ENGINE USING ETHANOL- GASOLINE BLENDS AS FUEL Proceedings of the International Conference on Mechanical Engineering 2011 (ICME2011) 18-20 December 2011, Dhaka, Bangladesh ICME11-TH-001 PERFORMANCE AND EMISSION CHARACTERISTICS OF A VARIABLE COMPRESSION

More information

for Pressure Vessels,Steam Boiler etc. (2.0MPa)

for Pressure Vessels,Steam Boiler etc. (2.0MPa) ( FULL BORE TYPE ) for Pressure Vessels,Steam Boiler etc. (.0MPa) SPECIFICATIONS Model name Code name Cap type Applicable fluid Set pressure range Applicable temperature End connection Materials Valve

More information

Published in: Proceedings of the 55th International Conference on Simulation and Modelling (SIMS 2014)

Published in: Proceedings of the 55th International Conference on Simulation and Modelling (SIMS 2014) Aalborg Universitet Implementation of Exhaust Gas Recirculation for Double Stage Waste Heat Recovery System on Large Container Vessel Andreasen, Morten; Marissal, Matthieu; Sørensen, Kim; Condra, Thomas

More information

THERMINOL D-12. heat transfer fluid. Low-odor, FDA-grade, NSF-registered cooling/heating fluid. -94 to 230 C. (--137 to 450 F)

THERMINOL D-12. heat transfer fluid. Low-odor, FDA-grade, NSF-registered cooling/heating fluid. -94 to 230 C. (--137 to 450 F) THERMINOL D-12 heat transfer fluid Low-odor, FDA-grade, NSF-registered cooling/heating fluid -94 to 230 C (--137 to 450 F) THERMINOL D-12 heat transfer fluid Min. use temp., 137 225 Max. bulk use temp.,

More information

Industrial Chemical Standards Supplied by

Industrial Chemical Standards Supplied by Industrial Chemical Standards Supplied by jagschemes@live.com.au Standard Specification for Glycol Base Engine Coolant for Automobile and Light- Duty Service 1. Scope 1.1 This specification covers the

More information

Biodiesel Production and Analysis

Biodiesel Production and Analysis Biodiesel Production and Analysis Introduction A key current focus in science and engineering is the development of technologies for generating and utilizing new sources of energy. Climate change, geopolitics,

More information

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER A wide range of desuperheaters, pneumatic actuators, strainers to satisfy all specifications of the power, pulp and paper industry and process gas applications FEATURES Fabricated construction Special

More information

ME Thermal Engineering Question Bank

ME Thermal Engineering Question Bank ME2301 - Thermal Engineering Question Bank UNIT I GAS POWER CYCLES Otto, Diesel, Dual, Brayton cycles, Calculation of mean effective pressure, and air standard efficiency -Actual and theoretical PV diagram

More information