icountbs icountbs Bottle Sampler Manual

Size: px
Start display at page:

Download "icountbs icountbs Bottle Sampler Manual"

Transcription

1 icountbs GB icountbs Bottle Sampler Manual DD _EN Rev 2012, Parker Hannifin Manufacturing (UK) Ltd

2 Contents About this manual... 3 Overview...3 Symbol glossary...4 Safety information...4 Laser information...5 Battery Information...5 Exclusion of liability...6 Conditions for safe use...6 Product registration...6 EC declaration of conformity...7 Product identification labels...8 Introduction... 9 Principles of operation...9 Servicing and calibration...9 Benefits...10 Product features...11 Operator panel...11 Mounting...11 Dimensions...12 Pneumatic/hydraulic circuit...12 Technical specifications...13 Default settings...14 Test Set-up and System Settings screens...15 Battery charging status icons...16 Contamination Standards...17 Setting up Using the Touch Screen...18 Electrical connections...18 Connecting/Disconnecting...19 Fluid connections...20 Connecting/Disconnecting...20 Remove the hose fittings...21 Printer paper installation...22 Getting started icountbs setup...24 icountbs registration...26 Setting time and date...29 Language setting...31 Preparation guidelines for testing...32 The effect of system conditions...32 Fluid sample extraction...32 Sample handling and preparation...33 Testing Inserting and removing sample bottles...34 Create new Test Sample Bottle Name...36 Sample testing...39 Viewing/Exporting test results...44 Test results (Filtering)...47 Importing Test results data...49 Reference Ordering information...51 Accessory Part Numbers...52 Fitting a replacement door seal...55 Parts required...55 Tools required...55 Procedure...55 Recalibration and servicing...57 Verification fluid...57 Li-ion batteries: Transport by Air Parker Hannifin Manufacturing (UK) Ltd

3 About this manual Overview Parker Hannifin s icountbs is the latest in laser particle counting technology. This mineral oil or aviation fuel contamination counter has been designed to provide accurate measurement results, providing high standards of performance and product quality. Its primary use is for laboratory conditions but is adaptable to allow its transport from one area to another with minimal testing disruption. With its Innovative touch screen technology, integrated battery power source and secure safe operating parameters, the new icountbs will deliver the performance characteristics by meeting accredited US Standards and achieving full ISO Certification to the latest ISO Medium Test Dust standards. The unit can be used in both on-line and off-line systems. The on-board power supply and integrated battery allows the icountbs to be taken to places that laboratory equipment has never gone before. Easy access wake-up switch High resolution touch screen Integrated printer Robust outer panel design Safety features Integrated battery Integrated stylus icountbs Bottle Sampler Manual 3

4 Symbol glossary The following symbols are used in this manual. WARNING Warning notices are used in this publication to emphasize that hazardous voltages, currents, temperatures, or other conditions that could cause personal injury exist in this equipment or may be associated with its use. A Warning notice is used in situations where inattention or misuse could cause personal injury. CAUTION A Caution notice is used in situations where inattention or misuse could cause damage to the equipment. If the equipment is used in a manner not specified by the manufacturer, the protection/performance may be impaired. CHECK Notes merely call attention to information that is especially significant to understanding and operating the equipment. You may need to check the orientation or tightness of connections, for example. SAFETY EQUIPMENT Some operations require special attention to safety, such as the use of safety glasses. Contact your local Parker Hannifin sales office if you have any concerns. SERVICE/REPAIR Any servicing or repair work must be carried out by a Parker-approved service centre. Contact your local Parker Hannifin sales office for recalibration services. WARNING A red band around a picture or instruction is used to emphasize that particular care is required to avoid the danger of personal injury or other hazard. CAUTION A yellow band around a picture or instruction is used to emphasize that particular care is required in carrying out the instruction. Examples are checking that plugs are keyed (i.e. correctly polarized) before they are fully inserted, or that hoses are fitted carefully so they do not leak. Safety information Please read the operating instructions before use and refer to this Handbook whenever appropriate during use. Before operating the icountbs ensure all electrical connections, hoses and fittings are securely fitted to the appropriate standards. Check all hoses and fittings for wear and or damage. If replacements are required please order new parts using the Accessory Part Numbers on the Ordering Information section (page 52). Replace any loose or leaking hoses immediately. WARNING: High pressure oil or fuel systems can present a danger of serious personal injury. 4 Parker Hannifin Manufacturing (UK) Ltd

5 Laser information This product contains an infrared 5mW laser. Any dismantling of the product may result in dangerous exposure to laser radiation. The following information about the laser is located on the side panel of the product. WARNING: Users are not required to access the laser radiation source and should never do so. Battery Information This product contains a 14.8V 10Ah 7A Li-ion Polymer battery pack. WARNING : If it is necessary to access the battery compartment, please take necessary precautions. If in doubt, please contact Parker Hannifin for advice. CAUTION: Disconnect from Mains supply before accessing the battery compartment. Do not dismantle, short circuit or modify batteries in any way. Do not charge the battery outside of the icountbs product. Do not power on the icountbs without the battery fitted and connected. This Parker product has been shipped in accordance to IAATA Guidance for Lithium ion batteries in equipment. (Ref : ICAO Technical Instruction for the Safe Transport of Dangerous Goods by Air and the 52nd Edition (2010) off the IATA Dangerous Goods Regulations (DGR).) The product packing should be labelled with a notice of the following type: ATENCIÓN Batería de Ion-Litio NO CARGAR NI TRANSPORTAR LA BATERÍA SI ESTÁ DAÑADA Para más información Teléfono 0044 (0) icountbs Bottle Sampler Manual 5

6 Exclusion of liability Parker has made every endeavour to ensure the accuracy of the content of this document, however errors cannot be ruled out. Consequently, we accept no liability for such errors as may exist or for any damage or loss whatsoever which may arise as a result of such errors. All details are subject to technical modifications. Technical specifications are subject to change without notice. Conditions for safe use To ensure compliance with the certification, users are NOT permitted to open the unit under any circumstances. Doing so will invalidate the unit s calibration and it would NOT subsequently be suitable for calibrated use. Product registration NOTE: Registering your product online at allows us to offer a speedy response time should you have a Warranty claim or other difficulty within the first 12 months of purchase. NOTE: Do not dispose of the original packaging, as this is required to return the icountbs to the Condition Monitoring Service Centre safely for recalibration and servicing. 6 Parker Hannifin Manufacturing (UK) Ltd

7 EC declaration of conformity icountbs Bottle Sampler Manual 7

8 Product identification labels On the back panel On the side panel KEY Part number reference Serial number Date of manufacture (D.O.M.) Country of manufacture Refer to handbook Waste electrical and electronic equipment (WEEE) directive. End-of-life disposal is the responsibility of the user Name and address of manufacturer Conformity marking of product by notified body Laser warning 8 Parker Hannifin Manufacturing (UK) Ltd

9 Introduction Parker Hannifin s icountbs represents the most up-to-date technology in solid particle contamination analysis. The icountbs is a compact, durable, lightweight integrated laserbased particle detector module that provides a cost-effective solution to fluid management and contamination control. Principles of operation The icountbs measures particle contamination via a sample bottle or on line. The sampling interval can be defined by the user so that measurements may be taken as often as required. In contrast to other Parker particle counters (such as the CM20, LCM20, ACM20 or MCM20), the icountbs allows you to set the volume of the test sample and the number of measurements taken for each bottle sample. The results are reported immediately, but also stored in the unit s internal memory and may be downloaded later for analysis by third-party applications (such as Microsoft Excel). The icountbs has high levels of controlled accuracy, stability and sensitivity. Servicing and calibration Please refer to the Parker Hannifin Quality and Servicing booklet (FDCB272UK), supplied on CD. NOTE: Any servicing or repair work must be carried out by a Parker approved service centre. Contact your local Parker Hannifin Sales Company for recalibration details. The recommended period between recalibration is 12 months. NOTE: Do not dispose of the original packaging, as this is required to return the icountbs to the Condition Monitoring Service Centre safely for recalibration and servicing. icountbs Bottle Sampler Manual 9

10 Benefits Independent monitoring of system contamination trends Calibration by recognised on-line principles confirmed by relevant International Organization for Standardization (ISO) procedures Reporting codes indicate contamination levels to the following Contamination Standards: MTD ACFTD ISO 4406 : 1999 ISO 4406 : 1987 NAS 1638 ISO 4406 : 1991 AS4059 (Differential) NAS 1638 AS4059 (Cumulative) Jet Fuel AS4059 (Differential) AS4059 (Cumulative) GOST : 2001 Six fixed channel size analysis displayed Selectable test sample sizes 10, 20, 30, 40, 50, 60, 80 and 100ml Selectable Flush Sample Sizes 10, 15, 20, 25, 50 and 100ml Selectable number of samples taken in one time (dependant on the size of the volume and flush sizes selected) 1, 2, 3, 4 or 5 tests A low-cost solution to prolonging fluid life and reducing machine downtime Mineral fluid / Fuel-compatible construction Percentage saturation reporting (for the moisture sensor option) Testing capability of up to 500 continuous tests (override auto warning option available) Data exporting method to USB (in XML format) Modular design for easy servicing On-board high quality pump and motor configuration High resolution colour touch-screen panel with built in stylus Integrated printer (selectable on/off feature) Self-diagnostic software Power-saving Sleep mode with integrated Wake up / power button On- and off-line pressure capability: see the Ordering Information section (page 52) for available options. Integration package into the Parker MiniLab Environment: see the Ordering Information section (page 52) for available options. 10 Parker Hannifin Manufacturing (UK) Ltd

11 Product features Operator panel Integrated power supply and battery source On-board printer High resolution touch-screen with stylus KEY Power/Wake Up switch Printer access Stylus in holder Front door High resolution touch-screen KEY Power/Wake Up switch Printer access Stylus in holder Front door High resolution touch-screen Battery compartment USB connections A and B Main On/Off switch 9 Ventilation fan (DO NOT BLOCK) Mounting Best practice mounting orientation is to have the unit placed on a stable surface with easy access to the controls and touch-screen. CAUTION: Care should be taken not to drop or shock the units this type of damage may effect product performance and is not covered by warranty. Storage of unit should be dry conditions and with the test chamber door open. Contact Parker Hannifin if you require further advice installing the icountbs in your system icountbs Bottle Sampler Manual 11

12 Dimensions Dimensions are given in mm (inches) (20.7) (15.5) (16) 194 (7.6) (8.2) Pneumatic/hydraulic circuit 12 Parker Hannifin Manufacturing (UK) Ltd

13 Technical specifications Feature Principle of operation Dimensions (typical) Mass Unit environmental working temperature and humidity Unit environmental storage temperature and humidity Moisture sensor calibration Moisture sensor stability Specification Laser diode optical detection of actual particulates H 530mm x W 210mm x D 410mm Approx 18kg +5 C to +40 C ( 41 F to +104 F) 20 85% RH (tested at 30 C (86 F), non-condensing) +5 C to +40 C ( 41 F to +104 F) 10 90% RH (tested at 30 C (86 F), non-condensing) ±5% RH (over a compensated temperature range of +10ºC to +80ºC (+50ºF to +176ºF) ±0.2% RH typical at 50% RH in one year International codes ISO 7 to 21, NAS 0 to 12 Contamination standards Channel sizes Refer to Parker Guide to Contamination Standards (DD ) on CD ACFTD : ISO 4406:1987; ISO 4406:1991; NAS 1638; AS4509E (Diff); AS4509E (Cum); GOST : 2001 MTD : ISO 4406:1999; NAS 1638; AS4509E (Diff); AS4509E (Cum) Channel Sizes: MTD µm(c) ISO 4406:1999 NAS 1638 AS4059E (Diff) AS4059E (Cum) Jet Fuel > >4 >4 > >6 >6 > >14 >14 > >21 >21 > >38 >25 >70 >70 >70 >70 >30 Channel Sizes: ACFTD µm ISO 4406:1987 NAS 1638 AS4059E (Diff) AS4059E (Cum) GOST 17216:2001 > >2 >2 5 > >5 >5 10 > >15 >10 25 > >25 >25 50 > >50 > >100 >100 >100 >100 > Calibration Recalibration Fluid compatibility Fluid management Viscosity range ACFTD : fully traceable to gravimetric first principles MTD : via a certified primary ISO automatic particle detector using ISO principles, with particle distribution reporting to ISO 4406:1996 Contact Parker Hannifin Manufacturing (UK) Ltd for advice Mineral-based oils and petroleum-based fuel. Contact Parker Hannifin Manufacturing (UK) Ltd for advice on other fluid compatibility Selectable on screen between 10 to 100ml 1 to 300cSt icountbs Bottle Sampler Manual 13

14 Feature Working pressure Flow range through icountbs Specification 3 bar maximum input pressure, if used on-line. Contact Parker Hannifin Manufacturing (UK) Ltd for further advice Test: 60ml/min Connection interface (On Line) INLET: 6mm push-fit, DRAIN: 4mm push-fit (ACC6NN031) see page 54 Fluid operating temperature (Oil) Fluid operating temperature (Fuel) +5 C to +80 C (+41 F to 176 F) -20 C to +70 C (-4 F to 158 F) Sample bottle size Parker Standard Bottle 250ml for use in icountbs (ACC6NW001 for 2-bottle pack; ACC6NW002 for 50-bottle pack) see page 53 Flush sample size Memory storage Selectable option within the icountbs Software: 10ml to 100ml 500 tests (Integrated Warning Level) Printer Thermal dot line printer paper (ACC6NW005) see page 53 Battery type Polymer Lithium Ion Battery pack (ACC6NW032) see page 54 Power requirements Integrated supply into the icountbs unit Certification EC Declaration of Conformity see page 7 Default settings Parameter Value Bottle name [Blank] Standard ISO 4406 : 1999 Flush Volume 10ml Samples 1 Volume Sample 100ml Auto Print Don t print Date Format DD / MM / YYYY Time Format 24-hour clock Date Default date leaving factory Time Default time leaving factory Language English Delete memory when full No Delete test file when exported No 14 Parker Hannifin Manufacturing (UK) Ltd

15 Test Set-up and System Settings screens KEY TEST SET-UP SCREEN Current Test number Battery charging status (see page 16) Turn off unit Start a new test Browse all previous tests System Settings for all other functions: Date/Time Screen calibration Registration Language selection System Information User Configuration Help Update software (Parker only) Calibration check (Parker only) Default setting reset (see page 14) Return to last screen displayed KEY SYSTEM SETTINGS SCREEN Battery charging status (see page 16) System Information screen Setting Date and Time screen User Configuration Test Set-up screen (see page 37) Parker use only Registration setting (see page 26) Language setting (see page 31) icountbs Bottle Sampler Manual 15

16 Battery charging status icons Icon Indicates Comment No battery fitted Battery should be fitted at ALL times in the unit. Do NOT disconnect the battery without discussing with Parker Hannifin Manufacturing (UK) Ltd Full charge Battery topped as required to maintain close to full charge (>95%) Slow charge (>80%) Fast charge (<80%) Charging fault Battery fault or charging circuit fault 100% charge 100 Tests (Shop Air) / 64 Tests (Battery) 80% charge 86 Tests (Shop Air) / 56 Tests (Battery) 60% charge 74 Tests (Shop Air) / 51 Tests (Battery) 40% charge 56 Tests (Shop Air) / 37 Tests (Battery) 20% charge 41 Tests (Shop Air) / 26 Tests (Battery) 10% charge 20 Tests (Shop Air) / 11 Tests (Battery) <10% (flashing) 6 Tests (Shop Air) / 4 Tests (Battery) 2% (flashing) 4 Minutes of testing remaining (Shop Air) / 7 minutes of testing remaining (Battery) Note : A warning message is given on screen. If you encounter any problems with the battery, please refer to Battery Information on page 5, or contact Parker Hannifin Manufacturing (UK) Ltd. 16 Parker Hannifin Manufacturing (UK) Ltd

17 Contamination Standards See the Parker Guide to Contamination Standards (DD ) available on your CD. This publication makes available industry-recognized cleanliness specifications for both hydraulic fluid and fuel samples. icountbs Bottle Sampler Manual 17

18 Setting up Using the Touch Screen The icountbs is operated via the touch screen on the front of the product. You can choose features touching the required icons on the screen with your finger or a stylus. A stylus is housed in the front of the icountbs case. CAUTION: Do not use a sharp or pointed implement, as this may damage the touch screen. To clean the screen, a clean lint-free cloth is recommended to prevent static build up when cleaning the icountbs touch screen. If needed you may use a small amount of screen cleaning fluid sprayed directly onto the cloth and then applied to the touch screen. If you need further advice please contact Parker Hannifin. NOTE: Screen shots shown in this manual are to help you navigate the menu system. Electrical connections The Parker supplied power cables can only be used with the icountbs product. ACC6NW023 ACC6NW024 ACC6NW025 CAUTION: The electrical supply and charge usage and validity only valid when using the Parker Supplied Power Supply Cable (ACC6NW ). The electrical power adaptor should only be used in dry environments 18 Parker Hannifin Manufacturing (UK) Ltd

19 Connecting/Disconnecting 1 2 Ensure the power switch is in the OFF position. 3 4 Check the plug is fully located Turn on power to charge battery Battery charging status on front panel and by flashing green LED on power switch See Battery charging status icons on page 16 To disconnect, reverse the steps 4 to 2 icountbs Bottle Sampler Manual 19

20 Fluid connections The icountbs Is fitted with venting ports on the rear panel and the unit is supplied with two hoses (Vapour Release 4mm ACC6NW010 and Oil Drain 6mm ACC6NW009). CAUTION: The correct connection method and safety standards should be applied when fitting the icountbs vapour release and oil drain. If there is any leakage of oil around the vapour release or oil drain please clean with an appropriate lint free cloth and cleaning materials. Please refer to the operator manual or contact Parker Hannifin for advice Connecting/Disconnecting 1 2 Locate hoses. Note that the colour of the hoses supplied may vary. 3 4 Remove the blanking plugs (ACC6NN033) by pressing down on the connector sleeve and pull out the plug. Store the plugs carefully and replace them once testing is complete, to avoid leakage and external contamination. Connect the VAPOUR RELEASE (Ø 4mm) hose. Check that hose is firmly located 5 Connect DRAIN (Ø 6mm) hose. Check that hose is firmly located. Insert the 4mm and 6mm hose into bottle. To avoid spillage try to keep the bottle upright when using the icountbs. 20 Parker Hannifin Manufacturing (UK) Ltd

21 Remove the hose fittings 1 2 Switch off the POWER switch before removing the hoses. The power light may still flash if connected to a mains supply. To remove the VAPOUR RELEASE (Ø 4mm) hose, press down the connector sleeve and pull the hose out. There may be a small fluid leakage here. 3 4 To remove DRAIN (Ø 6mm) hose, press down the connector sleeve and pull the hose out. To avoid fluid leaking after use, fit the blanking plugs (ACC6NN033) icountbs Bottle Sampler Manual 21

22 Printer paper installation The icountbs has an internal printer which uses a thermal printer paper reel (ACC6NW005). CAUTION: Replace the printer roll (ACC6NW005) carefully. Please refer to the operator manual or contact Parker Hannifin for advice. 1 2 End of roll change paper Remove the printer cover 3 4 Remove the empty roller Insert empty roller into the new paper roll (ACC6NW005) 5 6 Press to open printer roller Feed the new paper roll through the printer 7 8 Seat the roller in printer Thread the paper roll through the printer. It should look like this. 22 Parker Hannifin Manufacturing (UK) Ltd

23 9 bk Close the printer clip The paper is shown correctly loaded bl bm Feed paper through the cover Locate the cover in icountbs unit bn click! Close the cover icountbs Bottle Sampler Manual 23

24 Getting started GB icountbs setup The icountbs is supplied with an integral touch-screen and stylus. CAUTION: Do not use any sharp items on the touch screen as this may damage the product and is not covered by any warranty. If in doubt please refer to the operator manual or contact Parker Hannifin for advice. See Electrical connections pages See Fluid connections (if applicable) pages Turn on unit 3 4 Panel button illuminates (flashes when charging) Locate stylus (ACC6NW031) Remove stylus 24 Parker Hannifin Manufacturing (UK) Ltd

25 A set of green indicators show a diagnostic test PASS A red indicator shows a possible fault condition. NOTE: If a fault indicator is illuminated, please contact Parker Hannifin Manufacturing (UK) Ltd for advice. Language selection screen NOTE: Other languages may be available; please contact Parker Hannifin Manufacturing (UK) Ltd for advice. icountbs Bottle Sampler Manual 25

26 icountbs registration 1 2 Go to parker.com/unlock to obtain registration code by entering product serial number Product Registration screen 3 4 Use the stylus to click on the registration key entry box Enter the product Registration Key and press Enter 26 Parker Hannifin Manufacturing (UK) Ltd

27 5 6 If registration is skipped, the unit automatically goes to the Test Set-up screen. NOTE: The unit may be locked until the product is registered. Please contact Parker Hannifin Manufacturing (UK) Ltd for advice. Press Reg Now. Unit returns to home screen 7 8 Register as soon as possible from the System Settings page and repeat steps 1 to 5 Once registered, the Registration icon is removed. View System Info screen for confirmation icountbs Bottle Sampler Manual 27

28 9 Registration is shown on the System Information screen 28 Parker Hannifin Manufacturing (UK) Ltd

29 Setting time and date IcountBS allows you to reconfigure the date and time so you can maintain accurate information on your test results. 1 2 From the System Settings screen, select Date & Time Select Date Format 3 4 Select one of the date formats from the drop-down list Select a date from the calendar icountbs Bottle Sampler Manual 29

30 5 6 Select a Time Format Update Time; hours and minutes are set separately 30 Parker Hannifin Manufacturing (UK) Ltd

31 Language setting IcountBS allows you to reconfigure the language settings if needed. 1 2 Go to System Settings; select Language Press a flag button to select the interface language. Note that language availability may change. Please contact Parker Hannifin Manufacturing (UK) Ltd for advice. 3 The unit returns to System Settings icountbs Bottle Sampler Manual 31

32 Preparation guidelines for testing The icountbs has been designed to reduce to a minimum effects that can make condition monitoring inaccurate or unreliable by eliminating many of the variables associated with contamination monitoring. Variation caused by different amounts of entrapped gas is suppressed by pressurising the sample with cleaned air. The analysis tube is supplied with an accurate amount of oil, through a fixed displacement pumping system, and the test method is closely controlled, removing other variables which could occur with bottle sampling. Unfortunately, there are other factors that are beyond the ability of the measuring device to control. These external factors, if carefully considered, can be controlled within strict limits so that sampling errors are minimized. These are categorised as: The effect of system conditions Fluid sample extraction Sample handling and preparation. In most instances, the adoption of simple controlled procedures will result in reliable trend monitoring. The effect of system conditions SYSTEM FLOW RATE Samples are best taken from a point in the system where the flow is turbulent (i.e. with a Reynolds Number greater than 4000). The turbulent flow creates a mixing action. Where the flow is streamlined or laminar, larger particulate may tend to settle toward the lower pipe surface and not be sampled. SYSTEM CONDITION CHANGES Changes in the system operating condition, flow, temperature, pressure or vibration can result in previously sedimented contaminant being retained into the flowing oil. It is also possible that these changes may cause partially contaminated filter elements to shed particulates into the system. Samples should therefore be extracted when the system is in a steady state condition: the result is less likely to be distorted by contaminant peaks. TAKING A SAMPLE Extract a sample while the system is operating under consistently controlled conditions. Adopt a consistent technique. Spill off at least 200ml of fluid to flush the sampling port of residual contaminant. Leave the bottle capped until you are ready to extract the sample. Fill the bottle to approximately 80% and cap immediately after extracting the sample. Fluid sample extraction FLOW RATE Variations in the sampling flow rate may affect the result from bottle samples. The flow rate through a sampling port from an operating hydraulic system will vary according to the system pressure, the port restriction and fluid viscosity. For accurate trend monitoring, it is necessary to maintain these conditions consistently when extracting Bottle Samples. SAMPLING VALVES There are a number of proprietary sampling valves available, which adhere to good theoretical principles. However, their high cost and precision is probably unnecessary for trend monitoring. SAMPLING POINTS Sampling points should enable extraction of a sample without changing the system s condition. Fine control needle valves are not desirable, as they have a tendency to silt up under some operating conditions, causing the distribution of contaminants in the fluid to be changed. The sampling port should however be protected to maintain cleanliness and thoroughly flushed before collecting the sample for analysis. 32 Parker Hannifin Manufacturing (UK) Ltd

33 Sample handling and preparation BOTTLE CLEANLINESS Bottles should have sealing screw caps, with both parts cleaned to a suitable level in accordance with ISO3722. Standard Parker Hannifin bottles (ACC6NW001 (2-pack) and ACC6NW002 (50-pack)) are supplied clean to ISO 13/11 or better in a Class 10,000 Clean Room. The bottle should remain capped until the time of sample filling and be re-capped immediately afterwards. SAMPLE MIXING Sedimentation of contaminant in a sample will occur, the rate of which is dependent upon both the fluid and particle characteristics. Visually check the fluid sample for any large particles before testing by holding up to a light source. If you can see large contaminants, you may want to reconsider if the sample is suitable for testing by the icountbs. Other methods of sample agitation have not been provided, as they are likely to inconsistently distort the analysis of results. Where facilities are available, mixing can be achieved using paint shakers and/or an ultrasonic bath. Take care when using ultrasonic baths to avoid distortion of the result by prolonged use, which could cause the breakdown of contaminants. Bottle samples can be sufficiently stirred by swirling and tumbling by hand, end-over-end. Samples should be analysed, without delay, once agitated. NOTE: Air bubbles are counted as contamination and may affect test results. High viscosity fluids may take longer to degas. For further information, please contact Parker Hannifin Manufacturing (UK) Ltd. RESULTS The first result from a bottle sample should be disregarded, as it could be distorted by fluid from a previous sample. Samples from different parts of a system will give different results. Consideration should be given to what monitoring is desired and where to extract samples from for trend monitoring to be performed. Ensure that there is a minimum of 30ml of sample fluid left in the bottle at the end of the test to avoid any air being drawn into the icountbs system. If this minimum level has not been maintained, please flush through with a new sample of at least 50ml. NOTE: If there is a spillage of test fluids in the chamber, please clean the icountbs with a clean lint-free cloth, with any appropriate cleaning fluids being applied to the cloth. It is important that whatever practices you adopt, you must perform them consistently. icountbs Bottle Sampler Manual 33

34 Testing GB Inserting and removing sample bottles 1 2 Pull to open door Ensure the door latch is clear of front 3 4 Chamber ready for sample Insert bottle holding drip tray in one hand, bottle in other and tilted at a slight angle. 34 Parker Hannifin Manufacturing (UK) Ltd

35 5 6 Ensure that the bottle is located centrally around the dip tube: the bottle should look like this. Bring door front to latch 7 Push door fully (click); the door should sit flush. You are now ready to test. icountbs Bottle Sampler Manual 35

36 Create new Test Sample Bottle Name You can create your own bottle sample names saving you time later on when performing tests. NOTE: Please contact Parker Hannifin Manufacturing (UK) Ltd if you need advice. 1 2 From the System Settings screen, select User Config for the main Test Set-up screen Click on Bottle Name text box for a list of bottle names 3 4 A drop-down list shows the bottle names currently in memory. To enter a new bottle name, click Enter Name Add a new bottle name prefix then click on the text box 36 Parker Hannifin Manufacturing (UK) Ltd

37 5 6 Type Bottle Name Prefix; press Enter Click on text box; press Add. 7 8 New bottle name prefix is added to the Prefix list Name order priority: highlight the name and press Up icountbs Bottle Sampler Manual 37

38 9 bk Name is moved up the list. Press Down to reverse the priority bl bm The main Test Set-up screen shows your new priority Your new name is selected To delete a bottle name, highlight the line and press Delete. Tick boxes give the option to delete old test data as memory becomes full, or to delete test data after it has been exported to USB memory (see page 46). The Home button returns you to the Test Set-up screen. bn CAUTION: Data is lost once Delete button is clicked 38 Parker Hannifin Manufacturing (UK) Ltd

39 Sample testing CAUTION: Please refer to the operator manual or contact Parker Hannifin Manufacturing (UK) Ltd for advice. See Electrical connections pages See Fluid connections (if applicable) pages See icountbs product setup page 24 See Preparation guidelines for testing pages and Inserting and removing sample bottles pages Test Set-up main screen Select your Bottle Name. See page 37 to set up new bottle names icountbs Bottle Sampler Manual 39

40 3 4 Select Standard Set Flush Volume 5 6 Set Number of Samples Set Volume per Sample 40 Parker Hannifin Manufacturing (UK) Ltd

41 7 8 Indicate if auto printing of results is required Set Start Test 9 bk Pressurising = stage of testing Total progress = progress of each test If you abort the test this warning screen is displayed icountbs Bottle Sampler Manual 41

42 bl bm Results screen: Summary codes for bottle Results screen: Total count values for bottle bn bo Results screen: Count values for bottle with Print option Results screen: If required, view your results using another reporting standard by selecting one from the drop-down list 42 Parker Hannifin Manufacturing (UK) Ltd

43 bp Results screen: Browse all your tests icountbs Bottle Sampler Manual 43

44 Viewing/Exporting test results 1 2 Select Browse Tests from the main Test Set-up screen List of Saved Tests is shown 3 4 Select individual results and show date. You can double-click the test name to view that test result. Click Browse Tests to view more test results 44 Parker Hannifin Manufacturing (UK) Ltd

45 5 6 Export results: Highlight the test result(s) you would like to export using the stylus Plug the USB in the back of the IcountBS 7 8 See page 50 Importing Test results data to import your XML results into a spreadsheet program. Press Export. The Export Complete message confirms a successful export icountbs Bottle Sampler Manual 45

46 9 CAUTION: Data is lost once Delete button is clicked To delete results, highlight the test result(s) for deletion using the stylus and select Delete. A warning is displayed before deletion. 46 Parker Hannifin Manufacturing (UK) Ltd

47 Test results (Filtering) 1 2 Browse results; select Filter Filtering Options page 3 4 Sort Results by Date order Select the order of sorting for showing results icountbs Bottle Sampler Manual 47

48 5 6 Filter Results by Date within a date range Filter Results by Prefix name Parker Hannifin Manufacturing (UK) Ltd

49 Importing Test results data You can import the test results from the bottle sampler into a spreadsheet. CAUTION: The example shown is for Microsoft Excel however there is other spreadsheet software available please contact Parker Hannifin Manufacturing (UK) Ltd for any advice. 1 2 Plug USB drive from IcountBS into your PC Open your PC spreadsheet program (for example Microsoft Excel) 3 Locate your data file; click Open 4 5 Open XML, check radio button to open As an XML table; click OK Check the box if required; click OK icountbs Bottle Sampler Manual 49

50 6 The test results from the icountbs have been imported into the spreadsheet 50 Parker Hannifin Manufacturing (UK) Ltd

51 Reference Ordering information The icountbs is supplied with the following items: Two 2 x 250ml Sample bottle kit Vapor / Waste Bottle 4mm and 6mm Blanking plugs Push-fit Quick release Air Line adapter CD manual Either UK, US or EUR Power Lead Spare Printer Roll Stylus Pen Battery with battery compartment panel Drip Tray. Key Version Options Region Part number IBS Ver 2 3 MS/Online 000 EUR IBS3000EUR IBS Ver 2 3 MS/Online 000 UK IBS3000UK IBS Ver 2 3 MS/Online 000 USA IBS3000USA IBS Ver 2 3 MS 100 EUR IBS3100EUR IBS Ver 2 3 MS 100 UK IBS3100UK IBS Ver 2 3 MS 100 USA IBS3100USA IBS Ver 2 3 Fuel 100F* EUR IBS3100FEUR NOTE: *For IBS3100 or IBS3100F (Fuel) product options, please contact Parker Hannifin Manufacturing (UK) Ltd before ordering. icountbs Bottle Sampler Manual 51

52 Accessory Part Numbers Description Power pack (UK 2m cable) Part number ACC6NW023 Power pack (US 2m cable) ACC6NW024 Power pack (EUR 2m cable) ACC6NW ml Sample bottle kit (x2) ACC6NW001 2 Bottles 250ml Sample bottle kit (x50) ACC6NW Bottles Vapour / waste bottle ACC6NW003 Printer paper reel ACC6NW Parker Hannifin Manufacturing (UK) Ltd

53 Description Door Seal Kit Part number ACC6NW016 Parker Transit Packaging Case ACC6NW020 On-line kit icountbs2 manual CD Please contact Parker Hannifin Manufacturing (UK) Ltd for specific details. ACC6NW022 ACC6NW026 Battery compartment panel ACC6NW027 Drip tray ACC6NW028 Replacement packing box and inserts ACC6NW030 Stylus pen ACC6NW031 icountbs Bottle Sampler Manual 53

54 Description Battery pack Part number ACC6NW032 Parker USB pen drive ACC6NW033 Low Pressure Hoses (4mm and 6mm), 1.5m ACC6NN031 Blanking plugs (4mm and 6mm) ACC6NN033 Verification Fluid SERMISC Parker Hannifin Manufacturing (UK) Ltd

55 Fitting a replacement door seal Parts required ACC6NW016 Door Seal Kit Tools required Isopropanol (also known as IPA, isopropyl alcohol, propan-2-ol) Silicone grease compound Small brush Torch Gloves (latex or similar). Procedure 1 2 Open door and remove door seal. Use isopropanol to clean the inside of the channel and the inside of the door, removing all traces of silicone grease. Using a syringe, apply silicone grease compound to the base of the channel. DO NOT apply this to the side walls of the channel. Use a brush to apply this evenly over the entire base of the channel. icountbs Bottle Sampler Manual 55

56 3 4 Insert the new O-ring from the top. Ensure that it is fitted so that the moulding split line is not on a mating face. Apply a small amount of silicone grease to a gloved thumb and feed the O-ring in evenly. Coat the whole of the O-ring evenly and then close the door. Using the torch, inspect the inner face of the door to ensure that there is an even witness mark on the machined surface. Any gaps that are present will be paths for air to escape. It may be necessary to re-fit the O-ring to get a good seal. 56 Parker Hannifin Manufacturing (UK) Ltd

57 Recalibration and servicing Parker recommends: Re-calibration every 12 months Servicing every 12 months CAUTION: Please contact Parker Hannifin Manufacturing (UK) Ltd if you require further advice on how to have your unit Calibrated or Serviced. Please do not dispose of the packing and return the IcountBS in its original case for any service, calibration or warranty claims. Verification fluid CAUTION: A verification of the icountbs can be carried out using specially dosed samples of oil (Accessory Part Number SERMISC049). Please contact Parker Hannifin Manufacturing (UK) Ltd if you require further advice. Li-ion batteries: Transport by Air WARNING: Please refer to your country/customs shipping terms and conditions for the safe transport of Li-ion batteries. Refer to IATA transport guidelines. (Ref : ICAO Technical Instruction for the Safe Transport of Dangerous Goods by Air, and the 52nd Edition (2010) of the IATA Dangerous Goods Regulations (DGR).) icountbs Bottle Sampler Manual 57

58 Parker Worldwide AE UAE, Dubai Tel: parker.me@parker.com AR Argentina, Buenos Aires Tel: AT Austria, Wiener Neustadt Tel: +43 (0) parker.austria@parker.com AT Eastern Europe, Wiener Neustadt Tel: +43 (0) parker.easteurope@parker.com AU Australia, Castle Hill Tel: +61 (0) AZ Azerbaijan, Baku Tel: parker.azerbaijan@parker.com BE/LU Belgium, Nivelles Tel: +32 (0) parker.belgium@parker.com BR Brazil, Cachoeirinha RS Tel: BY Belarus, Minsk Tel: parker.belarus@parker.com CA Canada, Milton, Ontario Tel: CH Switzerland, Etoy Tel: +41 (0) parker.switzerland@parker.com CN China, Shanghai Tel: CZ Czech Republic, Klecany Tel: parker.czechrepublic@parker.com DE Germany, Kaarst Tel: +49 (0) parker.germany@parker.com DK Denmark, Ballerup Tel: parker.denmark@parker.com ES Spain, Madrid Tel: parker.spain@parker.com FI Finland, Vantaa Tel: +358 (0) parker.finland@parker.com FR France, Contamine s/arve Tel: +33 (0) parker.france@parker.com GR Greece, Athens Tel: parker.greece@parker.com HK Hong Kong Tel: HU Hungary, Budapest Tel: parker.hungary@parker.com IE Ireland, Dublin Tel: +353 (0) parker.ireland@parker.com IN India, Mumbai Tel: IT Italy, Corsico (MI) Tel: parker.italy@parker.com JP Japan, Fujisawa Tel: +(81) KR South Korea, Seoul Tel: KZ Kazakhstan, Almaty Tel: parker.easteurope@parker.com LV Latvia, Riga Tel: parker.latvia@parker.com MX Mexico, Apodaca Tel: MY Malaysia, Subang Jaya Tel: NL The Netherlands, Oldenzaal Tel: +31 (0) parker.nl@parker.com NO Norway, Ski Tel: parker.norway@parker.com NZ New Zealand, Mt Wellington Tel: PL Poland, Warsaw Tel: +48 (0) parker.poland@parker.com PT Portugal, Leca da Palmeira Tel: parker.portugal@parker.com RO Romania, Bucharest Tel: parker.romania@parker.com RU Russia, Moscow Tel: parker.russia@parker.com SE Sweden, Spånga Tel: +46 (0) parker.sweden@parker.com SG Singapore Tel: SK Slovakia, Banská Bystrica Tel: parker.slovakia@parker.com SL Slovenia, Novo Mesto Tel: parker.slovenia@parker.com TH Thailand, Bangkok Tel: TR Turkey, Istanbul Tel: parker.turkey@parker.com TW Taiwan, Taipei Tel: UA Ukraine, Kiev Tel parker.ukraine@parker.com UK United Kingdom, Warwick Tel: +44 (0) parker.uk@parker.com US USA, Cleveland Tel: VE Venezuela, Caracas Tel: ZA South Africa, Kempton Park Tel: +27 (0) parker.southafrica@parker.com European Product Information Centre (24-hour) Freephone: (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) 2012 Parker Hannifin Corporation. All rights reserved. DD _EN Rev

Parflare ECO. Mobile Flaring Machine for Triple-Lok Hydraulic Fittings

Parflare ECO. Mobile Flaring Machine for Triple-Lok Hydraulic Fittings 37 Parflare ECO Mobile Flaring Machine for Triple-Lok Hydraulic Fittings It s also a piggy bank! Parflare ECO Economical. Simple. Safe. A full-fledged Triple-Lok fitting flaring machine at an economical

More information

Miniature Cartridge Valves Diameter 7, 15 & 21mm

Miniature Cartridge Valves Diameter 7, 15 & 21mm Miniature Cartridge Valves Diameter 7, 15 & 21mm C7, C15 & C21 Series C7, C15 & C21 Series Product Description These 2 & 3 way cartridge valves offer the most compact solution with a fast response time

More information

VV6 Auxiliary Valves

VV6 Auxiliary Valves Shuttle Valve Subject to alteration without prior notice. The curves and diagrams in this catalogue are typical examples only. While the contents of the catalogue are updated continuously, the validity

More information

The smart replacement for the Pall SRT UE Element Series

The smart replacement for the Pall SRT UE Element Series The smart replacement for the Pall SRT UE Element Series The smart move Now there s a smarter replacement for Pall SRT UE series elements: The Par Fit SmaRT1 series. The result of engineering investment

More information

Drive Controlled Power Units Variable Speed Drive Solutions with Energy Savings

Drive Controlled Power Units Variable Speed Drive Solutions with Energy Savings Drive Controlled Power Units Variable Speed Drive Solutions with Energy Savings Experience Hefty Energy Savings in a Simple Package An unregulated pump motor running at maximum speed is a blatant waste

More information

Accumulator Stations Overview. Accumulator and Cooler Division Europe

Accumulator Stations Overview. Accumulator and Cooler Division Europe Accumulator Stations Overview Accumulator and Cooler Division Europe Description: Accumulator module 3 x 20 Litre pressure line accumulators 2 x 4 Litre return line accumulators Fitted with pilot operated

More information

Push buttons and Visual indicators

Push buttons and Visual indicators Push buttons and Visual indicators Catalogue PDE2587TCUK June 2010 WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,

More information

PS1 Modular Interface Valve

PS1 Modular Interface Valve PS1 Modular Interface Valve PDE2626TCUK October 2009 Important! Before carrying out any service work, ensure that the valve and manifold have been vented. Remove the primary supply air hose to ensure total

More information

10MFP 10MFP Filtration Trolley with icountpd

10MFP 10MFP Filtration Trolley with icountpd 10MFP GB 10MFP Filtration Trolley with icountpd DD0000031_EN Rev- 2012, Parker Hannifin Manufacturing (UK) Ltd www.parker.com/hfde Contents Overview...3 Exclusion of Liability...3 Conditions for safe use...3

More information

Pulsation Dampers Stainless Steel. up to 690 bar range

Pulsation Dampers Stainless Steel. up to 690 bar range Pulsation Dampers Stainless Steel up to 690 bar range HY10-4020-DS/UK Features and Dimensions Design Features and Benefits 1 Shell CE certified in accordance with the PED (97/23/EC) where applicable. Manufactured

More information

Rotary Actuators. PV Series - Vane type

Rotary Actuators. PV Series - Vane type aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Rotary Actuators PV Series - Vane type Catalogue PDE2648TCUK February

More information

Push buttons and Visual indicators. Catalogue PDE2587TCUK September w w w. a r a p n e u m a t i k. p l. Autoryzowany dystrybutor Parker:

Push buttons and Visual indicators. Catalogue PDE2587TCUK September w w w. a r a p n e u m a t i k. p l. Autoryzowany dystrybutor Parker: Push buttons and Visual indicators Catalogue PDE2587TCUK September 2014 Autoryzowany dystrybutor Parker: 53-012 Wrocław ul. Wyścigowa 38 tel. 71 364 72 82 fax 71 364 72 83 w w w. a r a p n e u m a t i

More information

From Serial Number: 07PHG1001 to Date. Hydrogen Gas Generator. H2PEM-100 / H2PEM-165 / H2PEM-260 / H2PEM-510 Parts Manual

From Serial Number: 07PHG1001 to Date. Hydrogen Gas Generator. H2PEM-100 / H2PEM-165 / H2PEM-260 / H2PEM-510 Parts Manual From Serial Number: 07PHG1001 to Date Hydrogen Gas H2PEM-100 / H2PEM-165 / H2PEM-260 / H2PEM-510 Parts Manual Introduction This manual identifies the kits available for both preventative maintenance and

More information

Distribution Manifolds. for Process Instrumentation

Distribution Manifolds. for Process Instrumentation Distribution Manifolds for Process Instrumentation Contents Page 3 Hi-Pro Distribution Manifold Page 4 Hi-Pro Air Header Manifold Page 5 H Series Distribution Manifold Page 6 & 7 Part numbering WARNING

More information

IQAN-LC6-X05 Input Devices. Electronic Control Systems

IQAN-LC6-X05 Input Devices. Electronic Control Systems IQAN-LC6-X05 Input Devices Application The IQAN-LC6-X05 is a mini-coordinate joystick that incorporates ergonomic design with ruggedness, functionality, light weight and high flexibility for mobile market

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

GLF iprotect Series. Size 2 & 3 Tanktop Mounted Return Line Filters. Max. 800 l/min - 10 bar

GLF iprotect Series. Size 2 & 3 Tanktop Mounted Return Line Filters. Max. 800 l/min - 10 bar GLF iprotect Series Max. l/min - bar A compact, cost effective low pressure filter solution Designed with the iprotect patented filtration technology. The Parker GLF iprotect is designed to provide high

More information

Transair: Advanced pipe systems for Industrial Fluids

Transair: Advanced pipe systems for Industrial Fluids aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Transair: Advanced pipe systems for Industrial Fluids New 168mm diameter

More information

SNAPP Mobile Fuel Filter. Racor Filter Division Europe

SNAPP Mobile Fuel Filter. Racor Filter Division Europe SNAPP Mobile Fuel Filter Racor Filter Division Europe Now, getting the fuel filtration you need in a SNAPP. SNAPP. The fuel filter change that changes everything. The world turns to Racor for filtration

More information

Parflex SCR Literature

Parflex SCR Literature Parflex SCR Literature Parflex SCR Assemblies Electrically Heated aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Parflex

More information

ORIGA Stop Cylinders. ORIGA simply the first

ORIGA Stop Cylinders. ORIGA simply the first ORIGA ORIGA simply the first Pneumatic Pneumatic stop cylinders with hydraulic industrial shock absorbers for soft, rebound-free stopping of a conveyed load. Pneumatic Soft, rebound-free stopping of a

More information

Page 1. Version /2012 FDCB806UK

Page 1. Version /2012 FDCB806UK Version 1.0 05/2012 FDCB806UK Page 1 Page 2 Standard Kit Confirmation ParSmart and data cable Batteries Instruction and certificate Weather protector Rechargeable battery packs LCM20 Case Printer reel

More information

Global Mobile Systems Engineering

Global Mobile Systems Engineering Global Mobile Systems Engineering Motion Control Technology Center How we help you compete: Global Mobile Systems Engineering Intelligent motion control for mobile equipment Energy efficiency Utilization

More information

Carbon Dioxide Polishers PC02/0 - PC02/3 and MPLUS MPLUS Parts Manual. Original Language

Carbon Dioxide Polishers PC02/0 - PC02/3 and MPLUS MPLUS Parts Manual. Original Language Carbon Dioxide Polishers PC02/0 - PC02/3 and MPLUS4000 - MPLUS10000 Parts Manual EN Original Language Introduction This manual identifies the kits available for both preventative maintenance and unforeseen

More information

SBA Accumulator Safety Blocks. For working pressures up to 350 Bar (5075 psi)

SBA Accumulator Safety Blocks. For working pressures up to 350 Bar (5075 psi) SBA Accumulator Safety Blocks For working pressures up to 350 Bar (5075 psi) Contents Contents Page Introduction... 3 Technical Data... 4 Flow Data... 6 Pressure Relief Valve... 6 Manual and Electrical

More information

Precision Technology. ZP200 Series Screw Driven Lifting Table

Precision Technology. ZP200 Series Screw Driven Lifting Table Precision Technology ZP200 Series Screw Driven Lifting Table Parker Facility in Offenburg, Germany Manufacturing and Service for Precision Components in Europe 2 Precision Automation Applications and industries

More information

Compact EHA. Electro-hydraulic linear actuators for high power density applications

Compact EHA. Electro-hydraulic linear actuators for high power density applications Electro-hydraulic linear actuators for high power density applications Catalogue HY7-131/UK Introduction, Features and Benefits Catalogue HY7-131/UK Specification Introducing... The new from Parker delivers

More information

Legris Blowgun Range A Large Selection to Suit all Applications

Legris Blowgun Range A Large Selection to Suit all Applications aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding egris Blowgun Range A arge Selection to Suit all Applications ow Pressure

More information

Thrust Cylinders. Series C0D and C0P

Thrust Cylinders. Series C0D and C0P aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Thrust Cylinders Series C0D and C0P Catalogue PDE2563TCUK pril 2008

More information

Piston Accumulators. ACP Series (up to 275 bar)

Piston Accumulators. ACP Series (up to 275 bar) ACP Series (up to 275 bar) Introduction and Features Benefits Benefits Key Advantages of an ACP Series Piston Accumulator: High-strength crimped construction provides long, reliable service life Small

More information

Air Saver Unit. An environmentally friendly solution to reducing air consumption.

Air Saver Unit. An environmentally friendly solution to reducing air consumption. aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding An environmentally friendly solution to reducing air consumption. Catalogue

More information

ADEX. Miniature Directional Control Valves

ADEX. Miniature Directional Control Valves ADEX Miniature Directional Control Valves January 2010 Summary Page Presentation 3 Adex valves overview 4-5 / Series characteristics 6 R/R Series valves order codes 7 R/R Series manifolds order codes 8

More information

Air Oil Coolers. LAC with AC Motor for Industrial Use

Air Oil Coolers. LAC with AC Motor for Industrial Use Air Oil Coolers LAC with AC Motor for Industrial Use The Olaer Group is part of Parker Hannifin since July 1st, 2012. With manufacturing and sales in 14 countries in North America, Asia and Europe, the

More information

Connection Solutions. for Food Machinery and Process Applications. Instant Fittings, Tubing, Function Fittings, Couplers, Accessories

Connection Solutions. for Food Machinery and Process Applications. Instant Fittings, Tubing, Function Fittings, Couplers, Accessories aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Connection Solutions for Food Machinery and Process Applications Instant

More information

Compact EHA. Electro-Hydraulic Actuators for high power density applications. King Of Valve Co.,Ltd.

Compact EHA. Electro-Hydraulic Actuators for high power density applications. King Of Valve Co.,Ltd. for high power density applications Catalog HY22-311D 3/11 Introduction, Features and Benefits Introducing... The new from Parker delivers powerful, reliable linear movement. is a fully self-contained

More information

Compact EHA. Electro-Hydraulic Actuators for high power density applications

Compact EHA. Electro-Hydraulic Actuators for high power density applications for high power density applications Catalog HY22-311D 3/11 Introduction, Features and Benefits Introducing... The new from Parker delivers powerful, reliable linear movement. is a fully self-contained

More information

Energy Efficiency in Hydraulics. Potential savings with valve-controlled linear actuators

Energy Efficiency in Hydraulics. Potential savings with valve-controlled linear actuators Energy Efficiency in Hydraulics Potential savings with valve-controlled linear actuators Note This document and other information from Parker Hannifin GmbH & Co. KG, its subsidiaries, sales offices and

More information

AC30V series Pump Control Application

AC30V series Pump Control Application AC30V series Pump Control Application HA502134U001 Issue 1 Technical Manual aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

More information

Fluid property sensor

Fluid property sensor Fluid property sensor Continuously validation of fluid quality Modern mobile equipment calls for a hydraulic fluid ensuring profitable and reliable operation Description: The FPS is a novel fluid property

More information

Materials Handling. Dedicated Products, Systems and Solutions

Materials Handling. Dedicated Products, Systems and Solutions Materials Handling Dedicated Products, Systems and Solutions Materials Handling Machine Subsystems Dedicated products and system solutions by Parker Cab Engine 2 Chassis CONTROLLABILITY Smarter More flexible

More information

AC30V series Pump Control Application (US units)

AC30V series Pump Control Application (US units) AC30V series Pump Control Application (US units) HA502134U005 Issue 1 Technical Manual aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control

More information

Hi-Pro Ball Valve for High Performance Process Isolation

Hi-Pro Ball Valve for High Performance Process Isolation Hi-Pro Ball Valve for High Performance Process Isolation Catalog 419-HBV Hi-Pro Ball Valve for up to 1, psi/689 bar operations Product Description These high performance two piece bi-directional Ball Valves

More information

EO2-FORM F3 and PRO22 WorkCenter

EO2-FORM F3 and PRO22 WorkCenter Parker Worldwide AE UAE, Dubai Tel: +971 4 8127100 parker.me@parker.com FR France, Contamine s/arve Tel: +33 (0)4 50 25 80 25 parker.france@parker.com RO Romania, Bucharest Tel: +40 21 252 1382 parker.romania@parker.com

More information

Five Hoses. Two Fittings. One Solution. GLOBALCORE. The world s first high-performance, cohesive hose and fitting system.

Five Hoses. Two Fittings. One Solution. GLOBALCORE. The world s first high-performance, cohesive hose and fitting system. Five s. Two Fittings. One Solution. GLOBALCORE The world s first high-performance, cohesive hose and fitting system. Five s. Two Fittings. One Solution... Providing a simple solution of robust hydraulic

More information

Service Catalogue. K-MT, KE-MT, KEN-MT, KEN Series. False economy, can cost you dearly! Heatless Adsorption Dryers

Service Catalogue. K-MT, KE-MT, KEN-MT, KEN Series. False economy, can cost you dearly! Heatless Adsorption Dryers Service Catalogue Heatless Adsorption Dryers K-MT, KE-MT, KEN-MT, KEN Series False economy, can cost you dearly! Those who follow a set of simple but effective maintenance rules carry out preventative

More information

Energy Efficiency in Hydraulics. Making savings with the differential cylinder

Energy Efficiency in Hydraulics. Making savings with the differential cylinder Energy Efficiency in Hydraulics Making saings with the differential cylinder Note This document and other information from Parker Hannifin GmbH & Co. KG, its subsidiaries, sales offices and authorized

More information

Five Hoses. Two Fittings. One Solution. GLOBALCORE. The world s first high-performance, cohesive hose and fitting system.

Five Hoses. Two Fittings. One Solution. GLOBALCORE. The world s first high-performance, cohesive hose and fitting system. Five s. Two Fittings. One Solution. GLOBALCORE The world s first high-performance, cohesive hose and fitting system. Five s. Two Fittings. One Solution... Providing a simple solution of robust hydraulic

More information

GR Screw pump. High performance pump series for industrial and marine applications

GR Screw pump. High performance pump series for industrial and marine applications GR Screw pump High performance pump series for industrial and marine applications The Olaer Group is part of Parker Hannifin since July 1st, 2012. With manufacturing and sales in 14 countries in North

More information

Lightraulics Hollow Piston Tie Rod

Lightraulics Hollow Piston Tie Rod Lightraulics Hollow Piston Tie Rod Cylinders For 700 bar working pressure Product Specifications Working pressure Retraction pressure Test pressure Stroke length Maximum piston speed Barrel material Piston

More information

Spare Parts List Series VP04 Pneumatic Remote Control Valve

Spare Parts List Series VP04 Pneumatic Remote Control Valve Pneumatic Remote Control Valve Publication No HY17-8820/UK July 2004 Conversion factors 1 kg = 2.2046 lb 1 N = 0.22481 lbf 1 bar = 14.04 psi 1 l = 0.21997 UK gallon 1 l = 0.26417 US gallon 1 cm = 0.061024

More information

Drive Controlled Pump Efficient Hydraulic Drives with a System

Drive Controlled Pump Efficient Hydraulic Drives with a System Drive Controlled Pump Efficient Hydraulic Drives with a System Hydraulic System Solutions are th When it comes to linear movements, the power density of hydraulic drives remains unrivaled. The job now

More information

Gear Pumps/Motors Series PGP/PGM 500

Gear Pumps/Motors Series PGP/PGM 500 Gear Pumps/Motors Series PGP/PGM 500 Express Delivery Program Note This document and other information from Parker Hannifin GmbH, its subsidiaries, sales offices and authorized distributors provide product

More information

Racor Filter Division Europe

Racor Filter Division Europe Racor Filter Division Europe Crankcase Ventilation Products and Solutions Features and Benefits Racor Crankcase Ventilation Pop-up indicator Closed CCV Only Pop-up style indicator that alerts of a bypass

More information

Micro-Moduflex. Pneumatic micro-valve modular islands. Edition : January 2008 / Catalogue no. PDE2588TCUK-ev

Micro-Moduflex. Pneumatic micro-valve modular islands. Edition : January 2008 / Catalogue no. PDE2588TCUK-ev Micro-Moduflex Pneumatic micro-valve modular islands Edition : January 2008 / Catalogue no. PDE2588TCUK-ev Micro-Moduf lex Valve System The Micro-Moduflex valve islands are an inovation in the field of

More information

PCL4 Remote Control. Hydraulic Proportional Remote Control Valve

PCL4 Remote Control. Hydraulic Proportional Remote Control Valve Remote Control Hydraulic Proportional Remote Control Valve Catalogue Information Catalogue layout This catalogue has been designed to give an overview of the series of valves and to make it easy for you

More information

ORIGA SYSTEM PLUS simply the first. for pneumatic and electric linear drive systems

ORIGA SYSTEM PLUS simply the first. for pneumatic and electric linear drive systems ORIGA SYSTEM PLUS simply the first for pneumatic and electric linear drive systems ORIGA SYSTEM PLUS pneumatic and electric The ORIGA SYSTEM PLUS is the heart of both standard series and special solutions.

More information

Parker Legris: Connecting You to the Best in Technology

Parker Legris: Connecting You to the Best in Technology Parker Legris: Connecting You to the Best in Technology Principle and Advantages of the Push-In Fitting The push-in fitting is the most intuitive way of connecting tubes to a fitting in order to create

More information

Proportional Pressure Regulation Lucifer Programmable EPP4 regulators High Pressure, 1" and 2" Comfort range. Basic /4 " /2 " Comfort.

Proportional Pressure Regulation Lucifer Programmable EPP4 regulators High Pressure, 1 and 2 Comfort range. Basic /4  /2  Comfort. aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Basic 1 /4 " 1 /2 " Comfort 1 /4 " 1 /2 " Comfort 1 " /2 HP 1 " 2 "

More information

Cylinder Solutions Standard & Custom

Cylinder Solutions Standard & Custom Cylinder Solutions Standard & Custom Parker Hannifin is the world s largest manufacturer of Hydraulic, Pneumatic, Electro-Hydraulic and Electric cylinders. With our global presence in 50 countries, we

More information

FTIR3 OIL ANALYSER. Fully compliant ASTM oil measurements in the field.

FTIR3 OIL ANALYSER. Fully compliant ASTM oil measurements in the field. FTIR3 OIL ANALYSER Fully compliant ASTM oil measurements in the field. FTIR3 OIL ANALYSER Comprehensive oil and lubricant monitoring for optimum performance Contaminated or degraded oil and lubricants

More information

Chit Chats clients save up to 70% on U.S. and international postage.

Chit Chats clients save up to 70% on U.S. and international postage. ONTARIO RATE CARD 2018 Prices are valid from January 21, 2018 Chit Chats clients save up to 70% on U.S. and international postage. Ship your package to the U.S. as if you were in the U.S. Packages under

More information

Cylinder Solutions Standard & Custom.

Cylinder Solutions Standard & Custom. Cylinder Solutions Standard & Custom Parker Hannifin is the world s largest manufacturer of Hydraulic, Pneumatic, Electro-Hydraulic and Electric cylinders. With our global presence in 50 countries, we

More information

Rail Hoses. The Hose Range for European Rail Transportation

Rail Hoses. The Hose Range for European Rail Transportation Rail Hoses The Hose Range for European Rail Transportation INNOVATION AND COMPLIANCE Parker is a certified and well-experienced partner with a global presence for the leading players of the rail industry.

More information

PE Series. Economical Planetary Gearheads

PE Series. Economical Planetary Gearheads PE Series Economical Planetary Gearheads WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND

More information

Urchin 7 cflag.ifas.ufl.edu Page 1 of 2 Standard View Export All Visits Permalink Geo Location Jul 1, 2015 - Jul 31, 2015 First Date 2015 Compare to Past Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

More information

Pneumatic Valves Viking Lite Series. G1/8 - G3/8 body ported

Pneumatic Valves Viking Lite Series. G1/8 - G3/8 body ported aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Pneumatic Valves Series G1/8 - G3/8 body ported Catalogue PDE2658TCUK

More information

Breathable Compressed Air Purifier BAM10 - BAM 70

Breathable Compressed Air Purifier BAM10 - BAM 70 Breathable Compressed Air Purifier BAM0 - BAM 70 Engineering Data Sheet Description Technical Specification Flow Data Model Stated flows are for operation at 7 bar g (00 psi g / 0.7 MPa g) with reference

More information

PVL-B2 Inline valves. Stackable and Stand-alone. PDE2682TCUK October

PVL-B2 Inline valves. Stackable and Stand-alone. PDE2682TCUK October PVL-B2 Inline valves Stackable and Stand-alone PDE2682TCUK October 2016 ul. Wyścigowa 38, 53-012 Wrocław tel. 71 364 72 82, ara@arapneumatik.pl www.arapneumatik.pl Important! Before carrying out any service

More information

Air Oil Coolers. LOC for Industrial Use

Air Oil Coolers. LOC for Industrial Use Air Oil Coolers LOC for Industrial Use The Olaer Group is part of Parker Hannifin since July 1st, 2012. With manufacturing and sales in 14 countries in North America, Asia and Europe, the Olaer Group expands

More information

Transair : The Original Aluminium Pipework System for Industrial Fluids

Transair : The Original Aluminium Pipework System for Industrial Fluids aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Transair : The Original Aluminium Pipework System for Industrial Fluids

More information

Piston Pumps Series P2 / P3 Variable Displacement

Piston Pumps Series P2 / P3 Variable Displacement Piston Pumps Series P2 / P3 Variable Displacement Catalogue HY11-2600/UK July 2003 Contents Series P2/P3 Description Technical information 3 Ordering code 4 Control options LA and LB 6 Control options

More information

Spare Parts List PCL4 01/02/04/05

Spare Parts List PCL4 01/02/04/05 PCL 01/02/0/0 Hydraulic Proportional Remote Control Valve Series Publication No HY17-13/UK April 200 Conversion factors 1 kg = 2.20 lb 1 N = 0.221 lbf 1 bar = 1.0 psi 1 l = 0.21997 UK gallon 1 l = 0.217

More information

Spare Parts List Series K170LS

Spare Parts List Series K170LS Spare Parts List Effective date: April 02, 2014 Supersedes: April 09, 2013 Spare Parts List This list of spare parts is designed to give you a good idea of the components included in the product range

More information

Rotary Actuators. Series VRS / VRA Sizes 32, 40, 50, 63, 80, 100 & 125mm Rotation 96 O, 186 O and 366 O

Rotary Actuators. Series VRS / VRA Sizes 32, 40, 50, 63, 80, 100 & 125mm Rotation 96 O, 186 O and 366 O aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Rotary Actuators Series VRS / VRA Sizes 32, 40, 50, 63, 80, 100 & 125mm

More information

Aviation Fuel Contamination Monitoring. ACM20 Lab Unit. Fluid condition monitoring

Aviation Fuel Contamination Monitoring. ACM20 Lab Unit. Fluid condition monitoring Aviation Fuel Contamination Monitoring ACM20 Lab Unit 61 Fluid condition monitoring Aviation Fuel Contamination Monitoring ACM20 Lab Unit Features & Benefits Test Time: 2 minutes Repeat Test Time: Every

More information

Pneumatic cylinders. Series PX - Ø25 to Ø125 mm According to NFE and CNOMO

Pneumatic cylinders. Series PX - Ø25 to Ø125 mm According to NFE and CNOMO aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Pneumatic cylinders Series PX - Ø25 to Ø125 mm According to NFE49-001

More information

638 Series. Servo Drive from 1 to 15 A.

638 Series. Servo Drive from 1 to 15 A. 638 Series Servo Drive from 1 to 15 A WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY

More information

NV Series. High Speed Servo Motor.

NV Series. High Speed Servo Motor. NV Series High Speed Servo Motor WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY

More information

TK Series. Frameless Servo Motor

TK Series. Frameless Servo Motor TK Series Frameless Servo Motor WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY

More information

Global ISO Valves for the Rail Industry. ISO , 2 and 3 sizes

Global ISO Valves for the Rail Industry. ISO , 2 and 3 sizes Global ISO Valves for the Rail Industry ISO 5599-1 1, 2 and 3 sizes Catalogue PDE2607TCUK. April 2009 Summary... Isomax Railway applications... ISO specification... Generalities... Flow... Material specification

More information

Distribution Manifolds For Process Instrumentation

Distribution Manifolds For Process Instrumentation Manifolds For Process Instrumentation WAIG FAILUE, IMPOPE SELECTIO O IMPOPE USE OF THE PODUCTS AD/O SYSTEMS DESCIBED HEEI O ELATED ITEMS CA CAUSE DEATH, PESOAL IJUY AD POPETY DAMAGE. This document and

More information

Hydraulic Global Overview

Hydraulic Global Overview aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Hydraulic Global Overview Products and Systems for Industrial, Mobile

More information

AC 650G Series General purpose high performance AC drives

AC 650G Series General purpose high performance AC drives AC 650G Series General purpose high performance AC drives Catalogue 0.25 kw - 110kW 2009 At Parker, we re guided by a relentless drive to help our customers become more productive and achieve higher levels

More information

Fork through-beam sensors

Fork through-beam sensors Fork throughbeam sensors Features Wide range of sizes: fork widths from 2 to 220 mm Metal housings Integrated evaluation unit Connection by means of S8 connector Degree of protection Adjustable sensitivity

More information

Fork through-beam sensors

Fork through-beam sensors Fork throughbeam sensors Features Wide range of sizes: fork widths from 2 to 220 mm Metal housings Integrated evaluation unit Connection by means of S8 connector Degree of protection Adjustable sensitivity

More information

Bladder Accumulators Industrial (Legacy) 207 bar to 420 bar range

Bladder Accumulators Industrial (Legacy) 207 bar to 420 bar range ladder ccumulators Industrial (Legacy) 07 bar to 0 bar range HY0-008-S/UK Features and imensions ladder ccumulators 07, 0, 5 & 0 bar esign Features and enefits C Shell Oil Service - seamless shell, designed

More information

Mobile Motor/Pump. Accessories

Mobile Motor/Pump. Accessories Mobile Motor/Pump ccessories Content Contents Page Speed sensor for F11/F12 and V12/V14... 3 BT brake valve for F12/T12 motors... 5 BW2/SX2 brake/relief valve... 8 BW2/SX2 brake/relief valve... 9 BW21/SX21

More information

Infographics on Electromobility (January 2019)

Infographics on Electromobility (January 2019) Infographics on Electromobility (January 2019) Publisher: BMW Group Corporate Communications Electromobility Last Update: 04.01.2019 Contact: presse@bmw.de ELECTROMOBILITY IN GERMANY. SHARE IN NEW REGISTRATIONS

More information

testing to perfection MultiTest-i Technical Datasheet

testing to perfection MultiTest-i Technical Datasheet testing to perfection MultiTest-i Technical Datasheet MultiTest 0.5-i, 1-i & 2.5-i 0.5 kn 1 kn 2.5 kn Height Width Depth Vertical Daylight* MultiTest 0.5-i 1710 mm (67.3) 290 mm (11.4) 414 mm (16.3) 1359

More information

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018 QUARTERS 2017-2018 June 14, 2018 CONTENTS BASEPROTOTAL BASEPROCARS BASEPROLCV BASEPROHCV BASEPROBC Summation of cars, LCVs, HCVs, heavy buses Cars LCVs HCVs Heavy buses Note: The production of cars and

More information

Vacuum technology Moduflex vacuum generator Peripheral module

Vacuum technology Moduflex vacuum generator Peripheral module Vacuum technology Moduflex generator Peripheral module Catalogue PDE2548SLUK-ev Moduflex generator Summary Page Applications... 3 Vacuum technology... 4 Order codes...5 Complete generators and stand alone

More information

Push-Buttons and Visual indicators. Catalogue PD0C00018UK02-ev

Push-Buttons and Visual indicators. Catalogue PD0C00018UK02-ev Push-Buttons and Visual indicators Catalogue PD0C00018UK02-ev WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL

More information

Power Rod. Actuators and components

Power Rod. Actuators and components Power Rod Actuators and components 192-576N2 January 26 : Actuators and components Contents : Actuators and components... 2 : Actuators and components... 3 Overview... 4 PRA25, PRC25... 8 with outrigger

More information

Hydraulic Power Units 108 Series

Hydraulic Power Units 108 Series Hydraulic Power Units 18 Series Catalogue HY17-131/UK March 3 Catalogue HY17-131/UK Content 18 Series Content Page 18 Series hydraulic power units... 3 Typical applications... 3 Ordering code... 4 Information

More information

High Flow Valve Actuation Range

High Flow Valve Actuation Range aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding High Flow Valve Actuation Range NAMUR Valves G1/" & G1/" Piped Valves

More information

UView Mini Transilluminator

UView Mini Transilluminator UView Mini Transilluminator Instruction Manual Catalog #166-0531 Hardware Instruction Manual The UView mini transilluminator is suitable for research use only. It must be used by specialized personnel

More information

MC Drives. Low Voltage Mobile Drives for Induction Motors 24 to 96 VDC

MC Drives. Low Voltage Mobile Drives for Induction Motors 24 to 96 VDC MC Drives Low Voltage Mobile Drives for Induction Motors 24 to 96 VDC WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE

More information

Hydraulic Motors M3B - M4* Denison Vane Technology, fixed displacement

Hydraulic Motors M3B - M4* Denison Vane Technology, fixed displacement Hydraulic Motors M3B - M4* Denison Vane Technology, fixed displacement General Series M3B - M4*, Denison Vane Motors GENERAL M3B M4C - M4SC M4D - M4SD M4E - M4SE M4DC - M4SDC General characteristics...

More information

FIRST FOR PORTABLE PARTICLE COUNTING

FIRST FOR PORTABLE PARTICLE COUNTING FIRST FOR PORTABLE PARTICLE COUNTING FS9V2-RH & FS9V2-RH-HP - particulate and relative humidity monitoring The FS9V2-RH Particle Pal displays live cleanliness readings for particulate (ISO/NAS/SAE) and

More information

Tyre Filling. Nitrogen Tyre Inflator Range

Tyre Filling. Nitrogen Tyre Inflator Range Tyre Filling Nitrogen Tyre Inflator Range Air in tyres The air we breathe consists largely of nitrogen, oxygen and water. The oxygen and water contained in compressed air have a negative impact on tyres.