PRODUCT PRESENTATION SERIES kva. MTU Onsite Energy Systems GmbH All rights reserved

Size: px
Start display at page:

Download "PRODUCT PRESENTATION SERIES kva. MTU Onsite Energy Systems GmbH All rights reserved"

Transcription

1 PRODUCT PRESENTATION SERIES kva MTU Onsite Energy Systems GmbH All rights reserved

2 TODAY S AGENDA 01. Philosophy 02. Product Family Concept 03. Product Overview 04. Diesel Generator Set Ratings 05. Main Components 06. Peripheral Components 07. Summary Page 2 / MTU Onsite Energy Systems GmbH / 12/16/2013 MTU Onsite Energy Systems GmbH All rights reserved

3 01 PHILOSOPHY MTU ONSITE ENERGY SERIES 4000 GENSETS Page 3 / MTU Onsite Energy Systems GmbH MTU Onsite / 12/16/2013 Energy Systems GmbH MTU Onsite Energy Systems GmbH All/ rights All rights reserved reserved

4 PHILOSOPHY. Our job: Vision: Strategy: Providing reliable power for all customer applications under all environmental conditions We at Tognum set the standard as the preferred partner for the best solutions in power and propulsion. Maintaining leadership in product innovation. Broadening application and customer portfolio. Custom-made products. Integrating system and service offerings. Just like MTU engines, our gensets are: proven reliability exceptionally economical have outstanding load acceptance characteristics have outstanding load factors in all application groups designed for easy maintenance Page 4 / MTU Onsite Energy Systems GmbH / 12/16/2013

5 02 Product Family Concept Page 5 / MTU Onsite Energy Systems GmbH MTU Onsite / 12/16/2013 Energy Systems GmbH MTU Onsite Energy Systems GmbH All/ rights All rights reserved reserved

6 PRODUCT FAMILY CONCEPT. TARGET. Harmonization of our product design across all global MTU Onsite Energy locations Harmonization of our product design across all MTU Onsite Energy product series Harmonization of our product design to our customers requirements Page 6 / MTU Onsite Energy Systems GmbH / 12/16/2013

7 PRODUCT FAMILY CONCEPT. ACHIEVEMENTS. Significant enhancement of standard options Improved system integration ability Improved overall product quality Easier customization of the genset Page 7 / MTU Onsite Energy Systems GmbH / 12/16/2013

8 03 PRODUCT OVERVIEW Page 8 / MTU Onsite Energy Systems GmbH MTU Onsite / 12/16/2013 Energy Systems GmbH MTU Onsite Energy Systems GmbH All/ rights All rights reserved reserved

9 PRODUCT OVERVIEW. STANDARD SCOPE OF SUPPLY. Optimization Fuel consumption optimized TA-Luft optimized NEA optimized Generator Marathon generator Winding RTDs Base Frame Welded design Resilient engine and generator mounting Control Panel Control variant 1+ (cabinet without controller) Air Intake Standard dry air filter Fuel System Fuel main filter Starting / Charging Electric starter (24 VDC / 2x 9kW) Voltages 400V Page 9 / MTU Onsite Energy Systems GmbH / 12/16/2013

10 PRODUCT OVERVIEW. STANDARD SCOPE OF SUPPLY. Certification / Standards Technical Documentation Engine-generator set engine-generator set standard factory acceptance testing Applicable Performance class G3 BS-4999 VDE 0530 ISO 8528 NFPA 110 Generator IEC NEMA MG 1-22 Radio interference level N Operation and Maintenance Manual Product information (functional description) Operation, troubleshooting and maintenance instructions Tools list Fluids and Lubricants Specification Quick Reference Guide Engine DIN ISO 3046 SAEJ 1995 / J1349 Page 10 / MTU Onsite Energy Systems GmbH / 12/16/2013

11 PRODUCT OVERVIEW. OPTIONAL SCOPE OF SUPPLY. Voltages 380V, 415V 11kV Generator Oversized Marathon generator Medium voltage Marathon generator Leroy Somer generator (low & medium voltage) Bearing temperature sensor Anti condensation heaters (Standard for MV) Differential protection CT s Starting / Charging Starter battery Battery rack Battery charger (battery charging alternator is no longer part of our scope of supply) Cooling System Mechanical radiator (40 C & 50 C*) Electrical driven radiator (40 C & 50 C) Piping between engine and radiator incl. flexible hoses Jacket water heater Radiator front protection Lubrication System Lube oil extraction pump * 50 C mechanical driven radiator is not available for genset models with 20V4000G63L engine Page 11 / MTU Onsite Energy Systems GmbH / 12/16/2013

12 PRODUCT OVERVIEW. OPTIONAL SCOPE OF SUPPLY. Fuel System Fuel pre filter Fuel pre filter with water separator and water level sensor Fuel pre filter switchable with water separator and water level sensor Fuel return cooler integrated into radiator Fuel return cooler (loose delivery) Exhaust System Silencer Silencer for use w/o Y-pipe Silencer for use with Y-pipe Air Intake Heavy duty air filters 10 db(a) 12V, 16V models - 30 db(a) 12V, 16V models All models 40 db(a) 12V, 16V models 20V models Y-pipe Exhaust bellows with connecting flange Page 12 / MTU Onsite Energy Systems GmbH / 12/16/2013

13 PRODUCT OVERVIEW. OPTIONAL SCOPE OF SUPPLY. Control Panel Basler controller Deif controller Island operation (Control Variant 2) Automatic Mains Failure (AMF) operation to be combined with Automatic Transfer Switch (ATS) (Control Variant 3a) Automatic Mains Failure (AMF) operation to be combined with electrical interlocked circuit breakers (Control Variant 3b) Circuit Breaker Manual operated circuit- breaker IEC 3/4 pole Electrical operated circuit- breaker IEC 3/4 pole Automatic transfer switch Circuit breakers as stand-alone solution Island parallel operation (Control Variant 4) Automatic Mains Failure (AMF) operation with mains restoration synchronization (Control Variant 5) Mains parallel operation of a single genset (Control Variant 6) Mains parallel operation of multiple gensets (Control Variant 7) Page 13 / MTU Onsite Energy Systems GmbH / 12/16/2013

14 04 RATINGS Page 14 / MTU Onsite Energy Systems MTU GmbH Onsite / 12/16/2013 Energy Systems GmbH MTU Onsite Energy Systems GmbH All/ rights All rights reserved reserved

15 RATINGS. POWER RATINGS DEFINITION OF MTU OE. Power declaration for genset (ISO ) MTU Ratings Emergency Standby Power (ESP) Maximum power during a variable electrical power sequence Operating hours per year: 200 Load factor: < 70% Standby power (3D) Operating hours per year: 500 Load factor: < 85% Prime Power (PRP) Maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load Operating hours per year: unrestricted Load factor: < 70% Prime power (3B) Operating hours per year: unrestricted Load factor: < 75% Page 15 / MTU Onsite Energy Systems GmbH / 12/16/2013

16 RATING RANGE. 3B. Genset Model Engine Fuel consumption optimized 3B Rating in kva* 40 C / 400m (NEA: 40 C / 100m) TA-Luft optimized NEA optimized DP1500D5S 12V 4000G DP1650D5S 12V 4000G DP1800D5S 12V 4000G DP2000D5S 16V 4000G DP2250D5S 16V 4000G DP2500D5S 20V 4000G DP2800D5S 20V 4000G DP3000D5S 20V 4000G63L * Ratings refer to Marathon generators and different voltages from 380V to 11kV. Ratings range covers the radiator options (mechanical radiator and electrical driven radiator) and generator options (oversized, derating optimized and medium voltage. Page 16 / MTU Onsite Energy Systems GmbH / 12/16/2013

17 RATING RANGE. 3D. Genset Model Engine Fuel consumption optimized 3D Rating in kva* 40 C / 400m (NEA: 40 C / 100m) TA-Luft optimized NEA optimized DS1650D5S 12V 4000G DS1750D5S 12V 4000G DS2000D5S 12V 4000G DS2250D5S 16V 4000G DS2500D5S 16V 4000G DS2650D5S 20V 4000G DS3100D5S 20V 4000G DS3200D5S 20V 4000G63L * Ratings refer to Marathon generators and different voltages from 380V to 11kV. Ratings range covers the radiator options (mechanical radiator and electrical driven radiator) and generator options (oversized, derating optimized and medium voltage. Page 17 / MTU Onsite Energy Systems GmbH / 12/16/2013

18 05 MAIN COMPONENTS Page 18 / MTU Onsite Energy Systems MTU GmbH Onsite / 12/16/2013 Energy Systems GmbH MTU Onsite Energy Systems GmbH All/ rights All rights reserved reserved

19 MTU SERIES 4000 ENGINE. TECHNICAL DATA. MTU Series 4000 engine: Main technical data Bore: Stroke: Displacement per cylinder: Injection system: 170 mm 210 mm 4.77 l Common rail Compression ratio: 16.5 Turbocharging: Single stage Compression ratio: 16.5 Exhaust system: Electronic: Cooling system: dry ADEC (Advanced Diesel Engine Controller) Smart Connect SAM (Service Application Module) Separate dual-circuit cooling Page 19 / MTU Onsite Energy Systems GmbH / 12/16/2013

20 MTU SERIES 4000 ENGINE. KEY BENEFITS. Best in class Fuel Economy High efficient common rail injection system Injection pressure up to 1800 bar MTU 16V4000G23 CAT 3516 BTA Cummins QSK 60-G4 Perkins TRG2 PRP Rating [kwm] 1,798 1,755 1,730 1,774 Fuel 100% load [g/kwh] Fuel 75% load [g/kwh] Page 20 / MTU Onsite Energy Systems GmbH / 12/16/2013

21 MTU SERIES 4000 ENGINE. KEY BENEFITS. Best in Class Transient Response Frequency and voltage deviations according to performance class G3 as per ISO % load acceptance according to NFPA 110 Higher displacement of MTU engine lower turbo boost pressure necessary better transient performance Load acceptance of MTU engine: >70% (depending on on-site engine conditions) Load acceptance of competitor engines: regularly <70% (depending on on-site engine conditions) Page 21 / MTU Onsite Energy Systems GmbH / 12/16/2013

22 MTU SERIES 4000 ENGINE. KEY BENEFITS. Proven Reliability Low vibration characteristics less stress on engine and peripheral components High reliability due to high displacement engine concept in comparison to competitors lower mean effective pressure less stress on engine Long time before overhaul (TBO): exceeding 30,000 hours in continuous applications MTU 16V4000G23 CAT 3516 B TA Cummins QSK 60-G4 Perkins TRG2 PRP Rating [kwm] 1,798 1,755 1,730 1,774 Cylinders Displacement [liters] Page 22 / MTU Onsite Energy Systems GmbH / 12/16/2013

23 MTU SERIES 4000 ENGINE. KEY BENEFITS. Highest Load Factors Prime Power 75% average load factor Emergency Standby Power 85% average load factor Higher load factors in comparison to competitors higher available power MTU 16V4000G23 CAT 3516 B TA Cummins QSK 60-G4 PRP Rating [kwm] 1,798 1,755 1,730 PRP Load Factor 75% 70% 70% Average available power [kwm] 1,349 1,229 1,211 Page 23 / MTU Onsite Energy Systems GmbH / 12/16/2013

24 MTU SERIES 4000 ENGINE. KEY BENEFITS. Outstanding De-rating Behaviour ADEC engine controller with Engine Site Condition Management System (ESCM) Higher availability of power for each application and site condition Full power up to 40 C and site altitude of 400m above sea level Page 24 / MTU Onsite Energy Systems GmbH / 12/16/2013

25 GENERATORS. OVERVIEW. General: Main supplier: Marathon Second supplier: Leroy Somer Leroy Somer Generators will be integrated as Release to Offer (RtO) Generators will be shown in price list Generators can be configured in IPAS Option is not 100% designed longer lead times Voltage Marathon Leroy Somer 380V / 400V / 415V RtO 380V / 400V / 415V Oversized 11kV RtO - Standard Option - Customized RtO Release to Offer Page 25 / MTU Onsite Energy Systems GmbH / 12/16/2013

26 MARATHON GENERATOR. STANDARD FEATURES. Low Voltage Alternator: Single-bearing Double bearing and rubber coupling for gensets with 20V4000 engine Damper cage/winding Disc coupling Brushless, self exiting, self regulating PMG excitation Digital voltage regulator 250% short circuit capability Heavy duty shielded ball bearings (min. life of 40,000 h), regreasable Ingress Protection: IP23 Insulation class H Anti-condensation heaters for gensets with 20V4000 engine Winding temperature sensors* Radio interference level N High load acceptance and low voltage dip Standard * In combination with Basler controller the analogue expansion module is required for the monitoring of the winding temperature. Page 26 / MTU Onsite Energy Systems GmbH / 12/16/2013

27 MARATHON GENERATOR. STANDARD FEATURES. Medium Voltage Alternator: Double bearing and rubber coupling for gensets Full amortisseur winding Disc coupling Brushless, self exiting, self regulating PMG excitation Digital voltage regulator 250% short circuit capability Heavy duty shielded ball bearings (min. life of 40,000 h), regreasable Ingress Protection: IP23 Insulation class H Temperature rise class F Anti-condensation heaters Winding temperature sensors* Radio interference level N High load acceptance and low voltage dip Option * In combination with Basler controller the analogue expansion module is required for the monitoring of the winding temperature. Page 27 / MTU Onsite Energy Systems GmbH / 12/16/2013

28 LEROY SOMER GENERATOR. STANDARD FEATURES. Low Voltage Alternator: Single-bearing Double bearing and rubber coupling for gensets with 20V4000 engine 2/3 pitch Disc coupling Brushless, self exiting, self regulating AREP / PMG excitation Analogue voltage regulator 300% short circuit capability Winding protection for tropical environments Regreasable bearings Ingress Protection: IP23 Insulation class H Anti-condensation heaters for gensets with 20V4000 engine Winding temperature sensors* Radio interference level N High load acceptance and low voltage dip * In combination with Basler controller the analogue expansion module is required for the monitoring of the winding temperature. Option Page 28 / MTU Onsite Energy Systems GmbH / 12/16/2013

29 LEROY SOMER GENERATOR. STANDARD FEATURES. Medium Voltage Alternator: Double bearing and rubber coupling for gensets 2/3 pitch winding Disc coupling Brushless, self exiting, self regulating AREP / PMG excitation Digital voltage regulator 300% short circuit capability Winding protection for tropical environments Regreasable bearings Ingress Protection: IP23 Insulation class H Temperature rise class H Anti-condensation heaters Winding temperature sensors* Radio interference level N High load acceptance and low voltage dip * In combination with Basler controller the analogue expansion module is required for the monitoring of the winding temperature. Option Page 29 / MTU Onsite Energy Systems GmbH / 12/16/2013

30 LOW VOLTAGE GENERATOR. COMPARISON. Feature Marathon Leroy Somer Bearings Single bearing (12V & 16V) Double bearing (20V) Single bearing (12V & 16V) Double bearing (20V) Bearings design regreasable regreasable Insulation class H H Winding pitch 2/3 2/3 Winding insulation standard tropical Winding RTDs Included in standard scope of supply* Included in standard scope of supply* Voltage regulation digital Analog; digital (optional) Short-circuit current 5 sec 250% 300% Excitation PMG AREP Ingress protection IP23 IP23 Anti condensation heater Optional Standard for 20V Optional Standard for 20V * In combination with Basler controller the analogue expansion module is required for the monitoring of the winding temperature. Page 30 / MTU Onsite Energy Systems GmbH / 12/16/2013

31 GENERATORS. BENEFITS. Two alternator brands available Higher flexibility to react on tender specifications and customer requirements Marathon as first alternator brand supplies their alternator in a special MTU design PMG excitation as standard for Marathon alternators Improved transient performance Constant power supply to the AVR regardless of the generator s terminal voltage (no influence of transient output voltage dips) No need for field flashing Manufactured in the US Leroy Somer as second alternator brand Premium product with premium image Manufactured in the EU (EUR1 qualified) Page 31 / MTU Onsite Energy Systems GmbH / 12/16/2013

32 BASE FRAME. FEATURES & BENEFITS. Standard 12V V 4000 Components with same position for all cylinder variants 20V 4000 Welded base frame design most rigid design also during transportation and on-site installation. Same position of main components and interfaces Simplified system integration Less height in comparison to actual Series 4000 base frame more feasable integration into containers or buildings, easier transport. Page 32 / MTU Onsite Energy Systems GmbH / 12/16/2013

33 CONTROL PANEL OVERVIEW Controller Brands: Two controller brands as standard option available: Basler Deif Common Features: Engine monitoring and protection. Alternator monitoring and protection Featuring all necessary functions for protection Featuring all necessary functions for indication Clear text display Programmable In- and Outputs Circuit breaker control Page 33 / MTU Onsite Energy Systems GmbH / 12/16/2013

34 PRE-WIRED CONTROL CABINET. VARIANT 1+. Features: Standard Fully pre-wired control cabinet without controller Control cabinet has the same dimensions as for control versions with controller. Dimensions: 1000 x 600 x 250 mm Benefits: Easy customization of different controller types and brands Standardized customer interface Page 34 / MTU Onsite Energy Systems GmbH / 12/16/2013

35 ISLAND OPERATION. VARIANT 2. Option Features: Control cabinet incl. controller for island operation. Genset is always connected on a deenergised network. No Automatic Mains Failure (AMF) operation No parallel operation Page 35 / MTU Onsite Energy Systems GmbH / 12/16/2013

36 AUTOMATIC MAINS FAILURE OPERATION. VARIANT 3A. Option Features: Automatic Mains Failure Operation (AMF) Controller with mains failure detection. Mains In case of a mains failure the genset will start automatically. Operation with automatic transfer switch (ATS) with own control unit that will switch over between mains and genset. Switchover with a short interruption of the supply. No parallel operation. GCB for Generator protection required Page 36 / MTU Onsite Energy Systems GmbH / 12/16/2013

37 AUTOMATIC MAINS FAILURE OPERATION. VARIANT 3B. Option Features: Automatic Mains Failure Operation (AMF) Controller with mains failure detection. In case of a mains failure the genset will start automatically. Operation with two electrically interlocked circuit breakers that are controlled by the genset. Switchover with a short interruption of the supply. No parallel operation Page 37 / MTU Onsite Energy Systems GmbH / 12/16/2013

38 Das Bild k ann ISLAND PARALLEL OPERATION. VARIANT 4. Option Features: Island parallel operation of multiple gensets in a network without mains connection After a remote start signal the gensets start, synchronize and switch on automatically. Load sharing Communication via CAN-Bus Page 38 / MTU Onsite Energy Systems GmbH / 12/16/2013

39 Das Bild k ann SINGLE GENSET MAINS PARALLEL OPERATION. VARIANT 5 & 6. Option Features (V5): Consumer MCB GB bus voltage sensing Automatic mains failure operation of a single genset. Controller with mains failure detection. In case of a mains failure the genset will start automatically. Switchover with a short interruption of the supply in case of a mains failure. When the mains restores the genset will synchronize to the mains for a short time Switchover without interruption of supply when the mains comes back Features (V6): G Mains Permanent mains parallel operation of a single genset. Peak shaving Page 39 / MTU Onsite Energy Systems GmbH / 12/16/2013

40 Das Bild k ann MULTIPLE GENSET MAINS PARALLEL OPERATION. VARIANT 7. Features: Option Permanent mains parallel operation of multiple gensets. The group of gensets will synchronize between each other. Load sharing between the gensets. Depending on the power demand the single gensets will start automatically if required. Page 40 / MTU Onsite Energy Systems GmbH / 12/16/2013

41 Das Bild k ann CONTROL PANEL BENEFITS The control panel can be installed on both sides of the base frame. Easy adaption to multiple installation situations. Two different controller brands as standard option available: Basler Deif Improved fit to customer requirements and tender specifications. High variety of controller specific options available. Easy customization to other controller brands due to standardized interface (variant 1+) Page 41 / MTU Onsite Energy Systems GmbH / 12/16/2013

42 Das Bild k ann CONTROL PANEL APPLICATIONS: BASLER & DEIF Application Basler Variant 1+ - Variant 2 Basler 2020 Deif AGC-4 Variant 3a Basler 2020 Deif AGC-4 Variant 3b Basler 2020 Deif AGC-4 Variant 4 Basler 2020 Deif AGC-4 Variant 5 Basler 2020 Deif AGC-4 Variant 6 Basler 2020 Deif AGC-4 Variant 7 - Deif AGC-4 Page 42 / MTU Onsite Energy Systems GmbH / 12/16/2013 Deif

43 Das Bild k ann CONTROL PANEL COMPARISON: BASLER & DEIF Feature Basler Deif Phase monitoring 3 phases for generator and mains 3 phases for generator and mains No. of generator sets in parallel operation Additional in-and outputs via expansion modules fully integrated in controler only for monitoring Remote control panel for complete genset control and monitoring Remote panel Page 43 / MTU Onsite Energy Systems GmbH / 12/16/2013

44 Das Bild k ann CIRCUIT BREAKERS FEATURES & BENEFITS Features: Manual & electrical actuated circuit breakers 3/4 pole Stand-alone design Optional cable connections GCB to generator in various lengths Benefits: Higher flexibility for system integration into containers and buildings. Circuit breaker can be placed on either side of the genset Circuit breaker can be placed in different distances to the genset Simplified customization of the genset Stand-alone is a manufacturer neutral concept No dependency between alternator and circuit breaker design No influence on other design features of the genset Page 44 / MTU Onsite Energy Systems GmbH / 12/16/2013 Option

45 Das Bild k ann 06 PERIPHERAL COMPONENTS MTU Onsite Energy Systems GmbH Page 45 / MTU Onsite Energy Systems GmbH / 12/16/2013 All/ rights reserved MTU Onsite Energy Systems GmbH All rights reserved

46 Das Bild k ann BATTERIES. FEATURES & BENEFITS. Technical Features: Lead acid batteries Complete harness Base frame mounted battery brackets Benefits: Battery bracket covers the top of the battery operation and maintenance staff may use the battery brackets as step Batteries are placed at the same position of the base frame for all cylinder variants Page 46 / MTU Onsite Energy Systems GmbH / 12/16/2013 Option

47 Das Bild k ann BATTERIE CHARGER. FEATURES & BENEFITS. Technical Features: Option AC input: 180 ~ 264VAC 130% peak load capacity Output voltage: 27.6VDC Output current: 40A UI charging characteristic Benefits: Standard option (mounted in control cabinet) even if the genset is delivered without controller less efforts for the customer because a battery charger is necessary for almost every control panel Standard scope is reduced by the battery charging alternator Increased genset efficiency Lead-Acid-Battery charging alternators are not suitable for NiCad-batteries Page 47 / MTU Onsite Energy Systems GmbH / 12/16/2013

48 Das Bild k ann JACKET WATER HEATER. FEATURES & BENEFITS. Technical Features: 3-phase system, 380V 415V Flow rate: 38 litre/min Adjustable thermostat from 32 C to 55 C Benefits: Uniform engine heating due to forced circulation of the coolant (more efficient heating than thermo siphon tank heaters) Extended hose life and reduced heater maintenance due to reduced outlet temperature Improved engine start-up Controls for automatic operation included Minimal material, space, and time for mounting due to compact design Page 48 / MTU Onsite Energy Systems GmbH / 12/16/2013 Option

49 Das Bild k ann LUBE OIL EXTRACTION PUMP FEATURES. Technical Features: Mechanical, semi rotary hand pump Vertical installation position, suction connection at bottom Alternative connection for extraction pump (switchable) Page 49 / MTU Onsite Energy Systems GmbH / 12/16/2013 Option

50 Das Bild k ann FUEL CONNECTION. FEATURES & BENEFITS. Technical Features: Fuel flow & return lines are mounted on base frame. Connections with valves. Benefits: Standardized customer interface, easier installation. Easy connection of external fuel tanks / systems. Page 50 / MTU Onsite Energy Systems GmbH / 12/16/2013 Option

51 Das Bild k ann FUEL PRE-FILTER WITH WATER SEPARATOR. FEATURES & BENEFITS. Technical Features: Model: SEPAR Single filter and switchable duplex filter avaialble. Water separator and fuel filter for light diesel fuel. 5-stage filtration (multi-stage centrifugal system). Water level sensor. Benefits: Fuel flow & return lines are mounted on base frame with. Most reliable water separator under harsh conditions. World-wide service network Compact design / High efficiency / Low flow restriction Long lifetime of filter element due to 5 stage filtration; the fuel runs through 4 filtration steps before it reach the filter element. Page 51 / MTU Onsite Energy Systems GmbH / 12/16/2013 Option

52 Das Bild k ann HEAVY DUTY AIR FILTER. FEATURES & BENEFITS. Technical Features: Two-stage engine air filter operating in medium to heavy dust conditions Proofed RadialSeal technology Filter insert and filter element combined Airflow: air inlet on side, outlet on end Horizontal installation Benefits: Complete genset mounted solution no additional efforts to add filters at the air inlets of containers or buildings Page 52 / MTU Onsite Energy Systems GmbH / 12/16/2013 Option

53 Das Bild k ann 07 SUMMARY MTU Onsite Energy Systems GmbH Page 53 / MTU Onsite Energy Systems GmbH / 12/16/2013 All/ rights reserved MTU Onsite Energy Systems GmbH All rights reserved

54 Das Bild k ann SERIES 4000 GENSET. SUMMARY. Significant enhancement of standard options Medium voltage alternators Oversized alternators Leroy Somer as second alternator brand Deif as second controller brand Control Variant 7 (mains parallel operation of multiple gensets) Mechanical driven radiator for 12V and 16V gensets Improved system integration ability Smaller base frame (height) smaller height for genset Same position for main components and interfaces at baseframe Control panel can be mounted on both sides of the genset Stand-alone circuit breaker Pre wired control cabinet (variant 1+) Page 54 / MTU Onsite Energy Systems GmbH / 12/16/2013

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2250 DIESEL GENERATOR SET MTU 16V4000 DS2250 380V 11 kv/50 Hz/Data Center Continuous Power/NEA (ORDE) Optimized MTU 16V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 12V4000 DS1750 DIESEL GENERATOR SET MTU 12V4000 DS1750 380V 11 kv/50 Hz/Standby Power/Fuel Consumption Optimized MTU 12V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product

More information

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET MTU 20V4000 DS3300 DIESEL GENERATOR SET MTU 20V4000 DS3300 380V 11 kv/50 Hz/Grid Stability Power/NEA (ORDE) Optimized MTU 20V4000G34F/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product

More information

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V4000 DS2500 DIESEL GENERATOR SET MTU 16V4000 DS2500 380V 11 kv/50 Hz/Data Center Continuous Power/TA-Luft Optimized MTU 16V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V4000 DS2500 DIESEL GENERATOR SET MTU 16V4000 DS2500 380V 11 kv/50 Hz/Standby Power/Fuel Consumption Optimized MTU 16V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product

More information

DIESEL GENERATOR SET MTU 12V4000 DS2250

DIESEL GENERATOR SET MTU 12V4000 DS2250 DIESEL GENERATOR SET MTU 12V4000 DS2250 380V 11 kv/50 Hz/Prime Power for Stationary Emergency/ Fuel Consumption Optimized/MTU 12V4000G34F/Water Charge Air Cooling Optional equipment and finishing shown.

More information

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS1650 DIESEL GENERATOR SET MTU 12V4000 DS1650 380V 11 kv/50 Hz/Prime Power for Stationary Emergency/NEA (ORDE) Optimized MTU 12V4000G14F/Water Charge Air Cooling Optional equipment and finishing shown. Standard

More information

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET DS01650D5S DIESEL GENERATOR SET DS01650D5S 380V 11 kv/50 Hz/Standby/NEA (ORDE) Optimized MTU 12V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits

More information

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 20V4000 DS4000 DIESEL GENERATOR SET MTU 20V4000 DS4000 11 kv/50 Hz/Prime Power for Stationary Emergency/Fuel Consumption Optimized MTU 20V4000G44LF/Water Charge Air Cooling Optional equipment and finishing shown. Standard

More information

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 16V2000 DS1000 DIESEL GENERATOR SET MTU 16V2000 DS1000 Prime Power: 910 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Low fuel

More information

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET DP03000D5S DIESEL GENERATOR SET DP03000D5S 380V 11 kv/50 Hz/Prime/TA-Luft Optimized MTU 20V4000G63L/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits

More information

DIESEL GENERATOR SET MTU 20V4000 DS3600

DIESEL GENERATOR SET MTU 20V4000 DS3600 DIESEL GENERATOR SET MTU 20V4000 DS3600 3.3-11 kv/50 Hz/Standby Power/NEA (ORDE) + Tier 2 Optimized MTU 20V4000G94F/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product

More information

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET DS03200D5S DIESEL GENERATOR SET DS03200D5S 380V 11 kv/50 Hz/Standby/Fuel Consumption Optimized MTU 20V4000G63L/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS

More information

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 16V2000 DS1100 DIESEL GENERATOR SET MTU 16V2000 DS1100 Standby Power: 1100 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Low

More information

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET DP01800D5S DIESEL GENERATOR SET DP01800D5S 380V 11 kv/50 Hz/Prime/Fuel Consumption Optimized MTU 12V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS //

More information

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 18V2000 DS1400 DIESEL GENERATOR SET MTU 18V2000 DS1400 Continuous Power: 1000 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Low

More information

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 16V2000 DS KVA DIESEL GENERATOR SET MTU 16V2000 DS1100 Data Center Continuous Power: 1000 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights //

More information

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET MTU 12V4000 DS2000 DIESEL GENERATOR SET MTU 12V4000 DS2000 380V 11 kv/50 Hz/Standby Power with overload/nea (ORDE) Optimized MTU 12V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS1650 DIESEL GENERATOR SET MTU 12V4000 DS1650 380V 11 kv/50 Hz/Grid Stability Power/Fuel Consumption Optimized MTU 12V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 20V4000 DS3100 DIESEL GENERATOR SET MTU 20V4000 DS3100 380V 11 kv/50 Hz/Standby Power/NEA (ORDE) Optimized MTU 20V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS

More information

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V4000 DS2500 DIESEL GENERATOR SET MTU 16V4000 DS2500 380V 11 kv/50 Hz/Standby Power with overload/ta-luft Optimized MTU 16V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 20V4000 DS2650 DIESEL GENERATOR SET MTU 20V4000 DS2650 380V 11 kv/50 Hz/Prime Power/TA-Luft Optimized MTU 20V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS

More information

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2250 DIESEL GENERATOR SET MTU 16V4000 DS2250 380V 11 kv/50 Hz/Standby Power/Fuel Consumption Optimized MTU 16V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT

More information

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2250 DIESEL GENERATOR SET MTU 16V4000 DS2250 380V 11 kv/50 Hz/Data Center Continuous Power/Fuel Consumption Optimized MTU 16V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard

More information

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 20V4000 DS3250 DIESEL GENERATOR SET MTU 20V4000 DS3250 Standby Power: 3250 KWel 13.8kV/60 Hz/Water Charge Air Cooling/Fuel Consumption Optimized Optional equipment and finishing shown. Standard may vary. Product Highlights

More information

PRODUCT PRESENTATION. MTU ONSITE ENERGY DIESEL GENERATOT SET kVA BASED SERIES MTU Onsite Energy GmbH All rights reserved

PRODUCT PRESENTATION. MTU ONSITE ENERGY DIESEL GENERATOT SET kVA BASED SERIES MTU Onsite Energy GmbH All rights reserved PRODUCT PRESENTATION MTU ONSITE ENERGY DIESEL GENERATOT SET 275 715kVA BASED SERIES 1600 MTU Onsite Energy GmbH All rights reserved AGENDA 01. Philosophy 02. Product Overview 03. Generator Set Ratings

More information

DIESEL GENERATOR SET MTU 10V1600 DS500

DIESEL GENERATOR SET MTU 10V1600 DS500 DIESEL GENERATOR SET MTU 10V1600 DS500 400 230 V/460 kva/50 Hz/Prime Power Series 1600 MTU 10V1600 Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Industry-leading

More information

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET MTU 12V1600 DS660 DIESEL GENERATOR SET MTU 12V1600 DS660 400 230 V/659 kva/50 Hz/Standby Power Series 1600 MTU 12V1600 Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Industry-leading

More information

POWER MODULE MTU 16V4000 DS2560

POWER MODULE MTU 16V4000 DS2560 POWER MODULE MTU 16V4000 DS2560 50 Hz: 1,912-2,560 kva/400v 60 Hz: 1,807-2,321 kwe/480v Optional equipment shown. Standard equipment may vary. Certifications and Standards // Emissions - Fuel optimized

More information

VIRTUS Diesel Gensets

VIRTUS Diesel Gensets VIRTUS Diesel Gensets DaimlerChrysler Off-Highway MTU Friedrichshafen GmbH 88040 Friedrichshafen Germany Phone +49 7541 90 87 73 Fax +49 7541 90 81 35 powergen@mtu-online.com www.mtu-online.com Detroit

More information

DIESEL GENERATOR SET DG00660D5

DIESEL GENERATOR SET DG00660D5 DIESEL GENERATOR SET DG00660D5 400 230 V/600 kva/50 Hz/Prime Series 1600 MTU 12V1600 Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Industry-leading average

More information

DIESEL GENERATOR SET MTU 4R0113 DS80

DIESEL GENERATOR SET MTU 4R0113 DS80 DIESEL GENERATOR SET 400 230 V/73 kva/50 Hz/Prime Power 400 230 V/80 kva/50 Hz/Standby Power IVECO NEF45 SM 2A Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits

More information

KVA KW KVA KW

KVA KW KVA KW ژنراتور : MTU موتور ديزل : MTU Standby Prime KVA KW KVA KW 990 792 900 720 ديزل ژنراتور ABYARAN Copyright 2014 - All Rights Reserved 1 موتور ديزل توليد كننده Manufacturer MTU مدل Model 16V2000G25TD تعداد

More information

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. FUEL/EMISSIONS STRATEGY Low fuel consumption SINGLE-SOURCE SUPPLIER Designed and built at Caterpillar ISO certified facilities

More information

Model NA 2 L

Model NA 2 L Model MP1500@6 2 L Frequency/Speed Voltage Prime Power Standby Power 50HZ/1500 RPM 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 230/400V 277/480V 1500 KVA 1200 KW 1500 KVA 1200 KW 1650 KVA 1320 KW 1650 KVA 1320

More information

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Specification sheet Diesel generator set QSK78 series engine 2750kVA - 3000kVA 50 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing optimum performance,

More information

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP) Standby Power: Standby power is defined as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering

More information

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 1500 ekw 1875 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

TPD2250H6.3 TECHNICAL DATA

TPD2250H6.3 TECHNICAL DATA TECHNICAL DATA DIESEL GENERATING SET TONTEK POWER LIMITED GREEN POWER SUPPLIER 50HZ www.tontekpower.com Page: 1/10 Specifications may change without Notice TPD2250H6.3 2250KVA/1800KW POWERED BY CUMMINS

More information

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP) PRAMAC GBW 45 Item code: SB450TPAY00 Main features Standby : 36 kw power LTP Rated prime : 34 kw power (PRP) Rated : kw continuous power (COP) Phases : 3 Voltage : 400 V Frequency : 50 Hz Engine : Perkins

More information

DIESEL GENERATOR DATA SHEET

DIESEL GENERATOR DATA SHEET YANAN DIESEL GENERATOR Powered by MTU Model:YN3500MTU *Drawing above for illustration purposes only Ⅰ. GENERAL DATA Prime Power kw/kva 2540 3175 Standby Power kw/kva 2800 3500 Frequency Hz/rpm 60 1800

More information

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability,

More information

Technical specification

Technical specification Technical specification Stand-by Generator Sets TECHNICAL INFORMATION Standby Power KVA 2500 (ESP) KW 2180 Prime Power KVA 2281 (PRP) KW 1975 Mechanical structure Open skid on base frame Engine CUMMINS

More information

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data Réf. 3303 GB - 2.33 / e - 04.02 35 30 25 20 15 10 ALTERNATORS LSA 50.1-4 Pole Electrical and mechanical data ELECTRICAL DATA ALTERNATORS LSA 50.1-4P 50 Hz - 1500 r.p.m. Insulation class H Excitation system

More information

Diesel generator set QSK78 series engine

Diesel generator set QSK78 series engine Specification sheet Diesel generator set QSK78 series engine 1950 kw - 2500 kw Description Cummins commercial generator sets are fully integrated power generation systems providing optimum performance,

More information

Model MP150 W W

Model MP150 W W Model MP150 W MP169@6 W Frequency/Speed Voltage Prime Power Standby Power 50HZ/1500 RPM 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 230/400V 277/480V 142 KVA 113.6 KW 160 KVA 128 KW 169 KVA 135.2 KW 156.2 KVA

More information

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability,

More information

Diesel generator set QSK23 series engine

Diesel generator set QSK23 series engine Specification sheet Diesel generator set QSK23 series engine 600 kw - 800 kw Standby Description Cummins commercial generator sets are fully integrated power generation systems providing optimum performance,

More information

POWERBLOCK GENERATION SYSTEMS

POWERBLOCK GENERATION SYSTEMS Product Specifications POWERBLOCK GENERATION SYSTEMS EPA Tier 2/Tier 4 Final Certified PowerBlock Systems Ratings: 600 kw/750 kva to 3125 kw/3910 kva 208V to 480V at 60 Hz 2 Patented Design The PowerBlock

More information

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts DIESEL GENERATOR SET PRIME 400 ekw 500 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Rating Definitions and Conditions

Rating Definitions and Conditions Model MP2 200 W Frequency/Speed Voltage Prime Power Standby Power 50HZ/1500 RPM 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 230/400V 277/480V 200 KVA 160 KW 220 KVA 176 KW Features Image for illustration purposes

More information

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts DIESEL GENERATOR SET PRIME 1200 ekw 1500 kva Caterpillar is leading the power generation market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Rating Definitions and Conditions

Rating Definitions and Conditions Model Frequency/Speed Voltage Prime Power Standby Power MP13 S MP15@6 S 50HZ/1500 RPM 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 230V/400V 277V/480V 12.5 KVA 10 KW 13.5 KVA 10.8 KW 15 KVA 12 KW 13.75 KVA 11

More information

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts DIESEL GENERATOR SET STANDBY 3000 ekw 3750 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

Rating Definitions and Conditions

Rating Definitions and Conditions Model GM125 W NA Frequency/Speed Voltage Prime Power Standby Power 50HZ/1500 RPM 230/400V 60HZ/1800 RPM 60HZ/1800 RPM 277/480V 230/400V 125 KVA 100 KW NA NA NA NA 137.5 KVA 110 KW NA NA NA NA Features

More information

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 400 ekw 500 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty type, 6 cylinder, water cooled engine 55 C tropical type radiator

More information

Rating Definitions and Conditions

Rating Definitions and Conditions Model MP300 M Frequency/Speed Voltage Prime Power Standby Power 50HZ/1500 RPM 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 230/400V 277/480V 300 KVA 240 KW 330 KVA 264 KW Features Image for illustration purposes

More information

Powered by Cummins Model:YN-95C

Powered by Cummins Model:YN-95C Powered by Cummins Model:YN-95C *Drawing above for illustration purposes only Ⅰ. GENERAL DATA Standby Power kva/kw 95 76 Prime Power kva/kw 85 68 Frequency Hz/rpm 60 1800 Voltage V 220 127 Current A 223

More information

55 KW / 69 KVA POWERED by

55 KW / 69 KVA POWERED by 55 KW / 69 KVA POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment to

More information

Rating Definitions and Conditions

Rating Definitions and Conditions Model MP250 M NA Frequency/Speed Voltage 50HZ/1500 RPM 230/400V Prime Power Standby Power 60HZ/1800 RPM 60HZ/1800 RPM 230/400V 277/480V 250 KVA 200 KW NA NA NA NA 275 KVA 220 KW NA NA NA NA Features Image

More information

Rental Power 800 kw. Specification sheet. Description. Features. Options

Rental Power 800 kw. Specification sheet. Description. Features. Options Specification sheet Rental Power 800 kw Description This Cummins rental package is a fully integrated mobile power generation system, providing optimum performance, reliability, and versatility for standby

More information

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES DIESEL GENERATOR SET PRIME 800 ekw 1000 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET PRIME 220 ekw 275 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

CGT Stamford UCI 274 E1

CGT Stamford UCI 274 E1 PERKINS 1106A-70TAG1 CGT Stamford UCI 274 E1 Generator model: UP-P150S-50 50Hz 3-Phase Power Factor Cos Φ = 0.8 MODEL Standby Power(50Hz) Prime Power(50Hz) UP-P150S-50 118kW / 148kVA 108kW / 135kVA Key

More information

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK 2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK 574 kwm at 1500 rpm 598 kwm at 1800 rpm Economic Power Mechanically operated unit fuel injectors with electronic control combined with carefully matched

More information

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous Specification sheet Diesel generator set QSK78 series engine 2750kVA - 3000kVA 50 Hz Data Center Continuous Description This Cuins coercial generator set is a fully integrated power generation system,

More information

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration 3512C Generator Set Electric Power Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES DIESEL GENERATOR SET STANDBY Mission Critical Standby 1120 ekw 1400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability,

More information

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features MODEL Standby Power(50Hz) Prime Power(50Hz) Diesel Generating Set 520KW / 650KVA NA Standard Features General Features: Engine (CCEC Cummins KTA19-G8) Radiator 40 O C max, fans are driven by belt, with

More information

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) PRO60-2 (R96 EUIIIa Equivalent) 50/60 Hz Switchable Rating Prime Product 60 kva / 48 kwe KEY FEATURES Rental Ready Features 24 hour dual wall tankbase Forklift pockets Fully certified single point lifting

More information

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features MODEL Standby Power(50Hz) Prime Power(50Hz) 300KW / 375KVA 275KW / 344KVA Standard Features General Features: Engine (CCEC Cummins NTA855-G2A) Radiator 40 O C max, fans are driven by belt, with safety

More information

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM Diesel Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications

More information

60 Hz FEATURES. Exclusively from your Caterpillar dealer

60 Hz FEATURES. Exclusively from your Caterpillar dealer L P & N A T U R A L G A S G E N E R A T O R S E T S STANDBY PRIME 60 Hz 100 kw 80 kw Model Standby kw (kva) Prime kw (kva) Natural Natural G100F3 100 (125) 85 (106.3) G90F3S 90 (90) 80 (80) G100F3S 100

More information

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM Diesel Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications

More information

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure PRO100-2 (EUIIIa Compliant) 50/60 Hz Switchable Rating Prime Product 100 kva / 80 kwe KEY FEATURES Rental Ready Features Forklift pockets Fully certified single point lifting eye Integrated heavy duty

More information

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts Designed to match performance and output characteristics of Caterpillar diesel engines Two-thirds pitch minimizes harmonic distortion and facilitates parallel operation DIESEL GENERATOR SET PRIME 220 ekw

More information

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts DIESEL GENERATOR SET PRIME 808 ekw 1010 kva Caterpillar is leading the power generation market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

DIESEL GENERATOR SET FEATURES

DIESEL GENERATOR SET FEATURES IE DIESEL GENERATOR SET FEATURES PRIME 2000 ekw 2500 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability,

More information

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 550KVA Generator Set Specification. Ultra Silent, Extended Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM

More information

Diesel generator set QSK50 series engine

Diesel generator set QSK50 series engine Specification sheet Diesel generator set QSK50 series engine 1100 kw 1500 kw Description Cummins commercial generator sets are fully integrated power generation systems providing optimum performance, reliability

More information

GMR - 67P 67P 09/05/2016 GMR - 067P

GMR - 67P 67P 09/05/2016 GMR - 067P 67P GMR - 67P Generator engineered and designed to work in a wide variety of applications where temporary power supply is needed. Versatility, high efficiency, high structural resistance, high degree of

More information

Diesel Generating Set. Generator Ratings

Diesel Generating Set. Generator Ratings 128KW / 160KVA 112KW / 140KVA MODEL Standby Power(Hz) Prime Power(Hz) General Features: Engine (Cummins 6BTA 5.9-G2) Radiator C max, fans are driven by belt, with safety guard 24V charge alternator Alternator:

More information

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH Prime* Voltage kva kw kva 380-415 180 144 200 Standby* kw 160 Ampere 251 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model

More information

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards) Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications

More information

WPS100/S EP Series. Features:

WPS100/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

Voltage 220 to or 1800 RPM

Voltage 220 to or 1800 RPM A TA Diesel Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications

More information

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features MODEL Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA Standard Features General Features: Engine(DCEC Cummins 6CTA8.3-G2) Radiator 50 O C max, fans are driven by belt, with safety guard

More information

Diesel generator set QSK78 series engine

Diesel generator set QSK78 series engine Specification sheet Diesel generator set QSK78 series engine EPA emissions 2000 kw - 2750 kw Description Cummins commercial generator sets are fully integrated power generation systems providing optimum

More information

Diesel Generating Set

Diesel Generating Set MODEL Standby Power(50Hz) Prime Power(50Hz) 1320KW /1650KVA 1200KW /1500KVA Standard Features General Features: Engine ( Perkins 4012-46 TAG2A ) Radiator 50 O C max,fans are driven by belt, with safety

More information

PPU Diesel Power 50/60Hz Containerized Generator Set

PPU Diesel Power 50/60Hz Containerized Generator Set 50Hz at 0.8 Power Factor 380-400V 3-Phase Rated Voltage 60Hz at 0.8 Power Factor 480V 3-Phase Rated Voltage PRIME STANDBY 800kW/1,000kVA 880kW/1,100kVA GENERATOR SET PERFORMANCE Application A factory designed

More information

Diesel generator set QSK23 series engine

Diesel generator set QSK23 series engine Specification sheet Diesel generator set QSK23 series engine 545 kw - 725 kw 60 Hz Data Center Continuous Description Cummins commercial generator sets are fully integrated power generation systems providing

More information

WPS350/S EP Series. Features:

WPS350/S EP Series. Features: Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

WPS150/S EP Series. Features:

WPS150/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features MODEL Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA Standard Features General Features: Engine (CCEC Cummins KTA38-G4) Radiator 40 O C max, fans are driven by belt, with safety

More information

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 650 ekw 812 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,

More information

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET PRIME 591 ekw 739 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 880 ekw 1100 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

1 / Genset general description

1 / Genset general description Measures: L : 3950 mm H : 2400 mm W: 1550 mm H Weight: 4600kg W L Hz 50 Hz V 400/230 V Water cooled Diesel 1500 r.p.m Open skid Illustrative image. CE Conformity 1 / Genset general description Engine Alternator

More information