Connecting External Battery Cabinet(s) to the UNITY/I 9910-UPS

Size: px
Start display at page:

Download "Connecting External Battery Cabinet(s) to the UNITY/I 9910-UPS"

Transcription

1 Connecting External Battery Cabinet(s) to the UNITY/I 9910-UPS IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS Tools required (use insulated tools): UNITY/I User Manual (IBM Document Number SC ) UNITY/I Installation Manual (IBM Document Number SC ) 1/4-inch and 7/16-inch nutdriver or wrench, Wire cutters and Phillips screwdriver Personal safety equipment as required by local code SAFETY INFORMATION Follow these important safety instructions when installing external battery cabinets. CAUTION Full voltage and current are always present at the battery terminals. Keep unauthorized personnel away from batteries. The batteries used in this system can produce dangerous voltages, extremely high currents and a risk of electric shock. They may cause severe injury if the terminals are shorted together or to ground (earth). Be extremely careful to avoid contacting battery terminals during battery installation. Do not touch uninsulated battery terminals. A qualified service person who is familiar with battery systems and required precautions must service the batteries. Batteries must be replaced with Best Power battery number BAT-0065 or equivalent. Best Power batteries come with a two-year warranty. Using batteries not supplied by Best Power invalidates any Best Power service agreement. Section 100: Identifying Your Unit : Stabilizer Bracket...4 Section 200: Standard UNITY/I UPS Models : Attaching the Ground Cable : Connecting the External Batteries for Standard UNITY/I UPS : Connecting Multiple Battery Cabinets...6 Section 300: Custom-fit UNITY/I UPS Models : Attaching the Ground Cable : Connecting the External Batteries for Custom-fit UNITY/I UPS : Connecting Multiple External Battery Cabinets...8 Section 400: Starting the UNITY/I UPS...8 Section 500: Setting the UNITY/I Parameters...9 Appendix A: Additional Parameter Tables...11 MLS-0393B Copyright , Best Power. All Rights Reserved.

2 CAUTION 1. Batteries contain caustic acids and toxic materials and can rupture or leak if mistreated. Released electrolyte is harmful to the skin and eyes. It may be toxic. Wear protective clothing and eye wear. Remove rings and metal wristwatches or other jewelry. Do not carry metal objects in your pockets; these objects could fall into the battery cabinet or UPS. Disconnect battery cabinets from each other before servicing. 2. Tools must be insulated so that they will not short battery terminals. Do not allow a tool to short a battery terminal to another battery terminal or to the cabinet. Do not lay tools or metal parts on top of the batteries. 3. The battery cabinet s chassis (ground or earth) must be connected to the UPS chassis (ground to earth). Ground additional battery cabinets to each other. (See the grounding instructions in this document.) 4. If you are replacing batteries or repairing battery connections, shut off the UPS, and remove both AC and DC input power. Follow the procedures for shutting down power found in the UNITY/I User Manual. For information on battery replacement, call Best Power s Worldwide Service or your local Best Power office. The UNITY/I weighs from 215 lbs/98 kg to 490 lbs/222 kg (with standard batteries) depending on model. External battery cabinets weigh 305 lbs/139 kg (with batteries). See Section 500 in the UNITY/I User Manual for UPS weights and dimensions. Make sure that you are prepared for the weights before you unload or move the UPS or battery cabinets. The temperature should be below 77 F (25 C) for the best battery performance. Batteries will be less efficient at temperatures below 65 F (18 C), and high temperatures will reduce battery life. Typically, at about 95 F (35 C), battery life will be one-half of what it would be at a normal temperature of 77 F (25 C). At about 113 F (45 C), battery life will be one-fourth of normal. Make sure that heaters, sunlight, air conditioners, or outside air vents are not directed toward the batteries. These can make temperatures within battery strings vary, which can cause differences in the batteries voltages. Eventually, this could affect battery performance. Use the Same Number and Type of Battery. To ensure continued superior performance of your UPS and to maintain proper battery charger operation, you must replace the batteries in the UPS or its battery cabinets with the same number of batteries. These batteries must be the same type as the original batteries: valve-regulated, low-maintenance. The replacement batteries should have the same voltage and ampere-hour rating as the original batteries. Any battery used with this UPS shall comply with the applicable requirements for batteries in the standard for emergency lighting and power equipment, UL 924. The installation must conform to national and local codes. Do You Need to Remove Ground from the Battery Terminal? If your local or national code requires you to ground either battery terminal, remove the connection from the terminal to ground (earth) before you service the batteries. If any battery terminal is inadvertently grounded, remove the source of the ground. Contacting any part of a grounded battery can cause a risk of electric shock. An electric shock will be less likely if you disconnect the ground connection before you service the batteries. Dispose of batteries properly. Assume that old batteries are fully charged. Use the same precautions you would use when handling a new battery. Do not dispose of battery or batteries in a fire. The battery may explode. Batteries contain lead. Many state and local governments have regulations for disposing of batteries. Page 2

3 Section 100: Identifying Your Unit External battery cabinet installation will vary depending on the type of UNITY/I UPS you have. Figure 1 shows a standard UNITY/I, and Figure 2 shows a UNITY/I with an external battery connector wired directly into the terminal block. Differences in the installation steps will be called out using Standard for models like Figure 1 and Custom-fit for models like Figure 2. Your receptacle panel may be different. Figure 1: Standard UNITY/I Figure 2: Custom-fit UNITY/I a. Make sure the keyswitch inside the front door of the UPS is turned to Off. Plug in the UPS to establish a ground connection. If you have a hardwired unit, see Section 206 of the UNITY/I User Manual (IBM Document Number SC ) for proper shutdown procedures. b. Place the battery cabinet(s) next to the UPS (see Figure 3). Leave at least 4-inches (100 mm) at the top, rear and sides of the battery cabinet(s) and 36-inches at the front of the battery cabinet(s) for ventilation. Best Power recommends a 36-inch (910 mm) service clearance on the right side of the battery cabinet(s). Figure 3: UNITY/I UPS and Battery Cabinets Page 3

4 101: Stabilizer Bracket a. Installation of the stabilizer bracket is required to meet TÜV requirements, per standards EN and EN b. Place the battery cabinet near its permanent location. You will need access to the back of the unit. The battery cabinet is easier to move before the stabilizer bracket is attached. c. Place the stabilizer bracket flat against the back panel of the battery cabinet. The base of the stabilizer bracket will rest on the floor. Figure 4: Stabilizer Bracket d. Use the bolts that came with your battery cabinet to secure the bracket to the back of the battery cabinet (see Figure 4). e. Repeat for additional battery cabinets. Section 200: Standard UNITY/I UPS Models See Section 300 for Custom-fit UNITY/I Models. 201: Attaching the Ground Cable a. The ground cable (green) is tie-wrapped with the DC cables on the back of the battery cabinet. Use a wire cutter to cut the section of tie-wrap that is threaded through the ring connector attached to the end of the ground cable. (See Figure 5). Battery Cabinet Be careful not to cut the cables. Do not cut any of the other tie-wraps. b. Pull the DC box out of the back of the battery cabinet (see Figure 6 on the next page). Remove the packing material from behind the DC box. Figure 5: Tie-wrap c. Remove the bolt that is labeled with the ground symbol from the back of the UPS (see Figure 6 on the next page). d. Put the bolt you removed from the UPS into the grounding cable s ring connector. Use the bolt to attach the ground cable to the UPS (see Figure 6 on the next page). e. If you have more than one battery cabinet, connect the ground cable of the second battery cabinet to the bolt on the first battery cabinet. Repeat for additional battery cabinets (see Figure 8 on page 6). Page 4

5 Battery Cabinet Standard UNITY/I Remove the DC box Attach the Ground Cable Figure 6: Attaching the Ground Cable to Standard UNITY/I models 202: Connecting the External Batteries for Standard UNITY/I UPS See Section 302 for Custom-fit UNITY/I models. a. Remove the two screws holding the metal plate to the back of the UPS (see Figure 7). You may discard these screws. b. Insert the DC box you removed in step 201-b into the back of the UPS (see Figure 7). Use the metal plate from the back of the UPS to cover this opening on the battery cabinet. Battery Cabinet Standard UNITY/I DC Box Remove this metal plate and insert the DC box into the UPS. Figure 7: Connecting the DC Box to the Standard UNITY/I UPS Page 5

6 c. If your UPS has only one external battery cabinet, attach the metal plate you removed from the UPS in step 202-a to the back of the battery cabinet where you removed the DC box in step 201-b (see Figure 7). Use the two screws attached at the base of the opening where you removed the DC box. You are now finished connecting one external battery cabinet; go to Section : Connecting Multiple Battery Cabinets a. If your UPS has more than one external battery cabinet, put the DC box from the second battery cabinet into the connector on the back of the first battery cabinet as shown. Attach the grounding cable from the second battery cabinet to the grounding bolt on the first battery cabinet. Additional battery cabinets are daisy-chained together in the same manner. (See Figure 8.) b. You are now finished connecting multiple battery cabinets to the UPS; go the Section 400. Battery Cabinet #3 Battery Cabinet #2 Battery Cabinet #1 Standard UNITY/I Figure 8: Connecting Multiple Battery Cabinets to Standard UNITY/I UPS Section 300: Custom-fit UNITY/I UPS Models See Section 200 for Standard UNITY/I Models 301: Attaching the Ground Cable a. The ground cable (green) is tie-wrapped with the DC cables on the back of the UPS. Use a wire cutter to cut the section of tie-wrap that is threaded through the ring connector attached to the end of the ground cable. Be careful not to cut the cables. Do not cut any of the other tie-wraps. For the Custom-fit UNITY/I UPS Models, do NOT use the green ground cable that is tiewrapped with the DC cables on the back of the battery cabinet. b. Remove the bolt labeled with the ground symbol from the back of the battery cabinet (see Figure 9 on the next page). c. Put the bolt you removed from the battery cabinet into the ring connector at the end of the UPS grounding cable. Use the bolt to attach the grounding cable to the battery cabinet (see Figure 9 on the next page). Page 6

7 Battery Cabinet Custom-fit UNITY/I DC Box Ground cable from Custom-fit UNITY/I connected to bolt on battery cabinet. Figure 9: Attaching the Ground Cable to Custom-fit UNITY/I Models 302: Connecting the External Batteries for Custom-fit UNITY/I UPS a. Pull the DC box out of the back of the battery cabinet. (See Figure 9.) Remove the packing material from behind the DC box. b. Attach the DC box to the battery connector that hangs from your UPS. (See Figure 10.) c. If your UPS has only one external battery cabinet, attach the metal plate included with these instructions (Best Power part number CAB-1086) to the back of the battery cabinet where you removed the DC box. (See Figure 10.) Use the two screws attached at the base of the opening where you removed the DC box. You are now finished connecting one external battery cabinet; go to Section 400. Battery Cabinet Custom-fit UNITY/I Use the metal plate included with these instructions to cover this opening on the battery cabinet. DC Box Remove this rubber cover and insert the DC box into the external battery connector. Figure 10: Connecting the DC Box to the Custom-fit UNITY/I UPS Page 7

8 303: Connecting Multiple External Battery Cabinets a. If your UPS has more than one external battery cabinet, put the DC box from the second battery cabinet into the connector on the back of the first battery cabinet. The ground cable from the DC box of the second battery cabinet is attached to the grounding bolt on the first battery cabinet. Additional battery cabinets are daisy-chained together in the same manner. (See Figure 10.) b. Attach the metal plate included with these instructions (Best Power part number CAB-1086) to the back of the last battery cabinet where you removed the DC box. Use the two screws attached at the base of the opening where you removed the DC box. You are now finished connecting multiple external battery cabinets; go the Section 400. Battery Cabinet #3 Battery Cabinet #2 Battery Cabinet #1 Custom-fit UNITY/I Figure 11: Connecting Multiple Battery Cabinets to Custom-fit UNITY/I UPS Section 400: Starting the UNITY/I UPS a. Hold down the Precharge switch on the front of the battery cabinet for five seconds. (See Figure 12.) b. Insert the key into the main DC switch on the front of the battery cabinet. Turn it clockwise, then pull the switch out, toward yourself. The ON-LINE LED will light on the battery cabinet. c. Turn the keyswitch inside the front door of the UPS to AUTO. The yellow BATTERY light will turn on briefly, then the green LINE light will turn on. Precharge Switch Keyswitch Figure 12: Battery Pack Front Panel If the red ALARM light is on: See Section 204 in the UNITY/I User Manual (IBM Document Number SC ) before continuing. Do not continue until the green LINE light has come on. If this is the initial installation of a hardwired unit, turn to the Voltage and Phase Check section in the UNITY/I Installation Manual (IBM Document Number SC ). Then, continue with Section 500 of this document to set the UPS parameters for increased battery capacity. Page 8

9 Section 500: Setting the UNITY/I Parameters Because the UNITY/I UPS is operating with increased battery capacity, three UPS parameters must be set: P-55 (Battery Capacity), P-57 (Runtime Constant 1), and P-58 (Runtime Constant 2). If you have more than one external battery cabinet, or if your UPS does not have internal batteries, see the tables in Appendix A to find the correct parameter value. To set these parameters: a. Determine the model number of the UPS and battery cabinet(s). The model number of the UPS is on the label by the keyswitch on the front of the UPS. The model number of the battery cabinet(s) is on a label by the power cable on the back of the battery cabinet. b. Determine if your UNITY/I UPS has standard internal batteries. c. Simultaneously hold down the [CANCEL] and [RUNTIME] keys for two seconds. Release the keys when the display shows P-00. Then, press [CANCEL]. The display will read 0. d. Enter the password Use the [%LOAD] key to increase the display to If you scroll past the number, use the [VOUT] key to decrease the value. e. Press [RUNTIME] to enter the password. The display should show 2. If the display is inactive (no keys are pressed) for five minutes, the password reverts back to level 0 and you must re-enter the password. f. Press [CANCEL] to return to the parameter number display (P-XX). The [CANCEL] key allows you to toggle between the parameter number and parameter value. g. Use the [%LOAD] to step to the parameter that you wish to change (P-55, P-57, or P-58). Use the [VOUT] key if you need to decrease the number. Then, press [CANCEL] to display the parameter value. See Tables 1-3 to determine the correct setting for Parameters 55, 57, and 58. Tables 1-3 are for units with internal batteries and one external battery cabinet. Press [%LOAD] to increase the setting, [VOUT] to decrease the setting. h. To enter the new value, press [RUNTIME]. The UPS beeps to indicate that the new value has been entered. If you do not wish to save a change that you have made, press [VLINE] and the value will remain at its original setting. i. To change the remaining parameters, repeat steps f - h. j. To escape parameter mode, press [VLINE] twice. Page 9

10 Table 1: Parameter 55 (Battery Capacity) Battery Cabinet UT3K UT5K EBPUT2W EBPUT3W Table 2: Parameter 57 (K1) Battery Cabinet UT3K UT5K EBPUT2W EBPUT3W Table 3: Parameter 58 (K2)* Battery Cabinet UT3K UT5K EBPUT2W EBPUT3W 2EEA 1770 * Parameter 58 is represented as a hexadecimal number. Page 10

11 Appendix A: Additional Parameter Tables If you have more than one external battery cabinet, or if your UPS does not have internal batteries, use the following tables to determine the correct parameter settings for your system. If there are more than three battery cabinets in a system, parameters will have to be calculated individually; call Best Power s Worldwide Service for more information. Use Table A to add up the amp-hours of each battery cabinet along with the amp-hours of the internal batteries to arrive at the total amp-hours for the system. For example, a UT5K with internal batteries, and two EBPUT2W battery cabinets would have a system amp-hour of: = 165A h. After determining the system amp-hours, set parameter 55 (Battery capacity) to this value. For information on setting battery parameters, see Section 500 of this document. You can use this value with the following tables to determine the values for parameters 57 (K1) and 58 (K2). Tables B and C correspond to particular UPS models. The system amp-hours are in the first column. The row shows the values to input for P-57 and P-58. Table A: Battery Amp-hours for UNITY/I 9910-UPS Models Model Number UT3K without internal batteries UT3K with standard batteries UT5K without internal batteries UT5K with standard batteries EBPUT2W EBPUT3W Battery A h Page 11

12 To determine P-57 and P-58 for the previous example (a UT5K with internal batteries and two EBPUT2W battery cabinets), use Table C for the UT5K with 33A h batteries. Find the system A h (165) in the first column. The row shows the value for P-57 is 1.00; the value for P-58 is Parameter 58 is shown as a hexadecimal number. If your unit has software v v.1.03, call Best Power s Worldwide Service for information on converting hexadecimal to decimal notation. Table B: UT3K with 33A h batteries or no internal batteries System A h P-57 P EEA Table C: UT5K with 33 h batteries or no internal batteries System A h P-57 P D B0 Page 12

Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450

Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450 Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450 PAT 609 P February 1, 1993 This PAT describes how to replace the battery in Patriot SPS 250, SPS 300, and SPS 450 units. Replacing the

More information

Replacing the Batteries in the Fortress LI 660

Replacing the Batteries in the Fortress LI 660 Replacing the Batteries in the Fortress LI 660 This FTS describes how to replace the batteries in Fortress LI 660 units. Batteries should be replaced by a qualified technician. If you have any questions

More information

Illuminator System Series CM

Illuminator System Series CM Illuminator System Series CM.5 kw 2.0 kw Installation Guide 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500 Fax: (610) 868-8686 Service: (610) 868-5400 www.myerspowerproducts.com

More information

Illuminator System Series CIII

Illuminator System Series CIII Illuminator System Series CIII 4.8 kw 16.7 kw Installation Guide 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500 Fax: (610) 868-8686 Service: (610) 868-5400 www.myerspowerproducts.com

More information

Installation And Operation Instructions

Installation And Operation Instructions Installation And Operation Instructions For PS Series Mini-Inverter Power Systems Models: PS-55-LP, PS-110-HP, PS-110-LP, PS-220-HP Surface (-S), Recessed (-R) and Ceiling T-Grid (-T) Mounted Versions

More information

Installation And Operation Instructions

Installation And Operation Instructions Installation And Operation Instructions For MPS Series Micro-Inverter Power Sytems Lead Calcium Battery Models: MPS-32 and MPS-55 Nickel Cadmium Battery Models: MPS-20 and MPS-35 Surface (-S), Recessed

More information

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva Start UP Guide Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

U N I T Y / Three-Phase Uninterruptible Power Systems UT3120, UT3160, UT Hz

U N I T Y / Three-Phase Uninterruptible Power Systems UT3120, UT3160, UT Hz U N I T Y / I TM Three-Phase Uninterruptible Power Systems UT10, UT160, UT0 60 Hz Planning and Installation Manual LTM-056A Copyright 1995, Best Power Technology, Inc. IMPORTANT SAFETY INSTRUCTIONS SAVE

More information

Installation And Operation Instructions

Installation And Operation Instructions Installation And Operation Instructions For LPS Series Micro Inverter Power Systems Lead Calcium Battery Models: LPS32 and LPS55 Nickel Cadmium Battery Models: LPS20 and LPS35 Surface (-S), Recessed (-R)

More information

Installation Instructions and User Manual For

Installation Instructions and User Manual For Installation Instructions and User Manual For Inverter Power Systems 1.0-17.5 KVA READ AND FOLLOW ALL SAFETY INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, you should always follow

More information

Installation Instructions and User Manual For. 100 Watt Inverter Power System

Installation Instructions and User Manual For. 100 Watt Inverter Power System Installation Instructions and User Manual For 100 Watt Inverter Power System Installation Instructions and User Manual For LiteGear 100 Watt Inverter Power System Warning: THIS PRODUCT CONTAINS CHEMICALS

More information

U N I T Y / Three-Phase Uninterruptible Power Systems UT310, UT315, UT320, UT Hz

U N I T Y / Three-Phase Uninterruptible Power Systems UT310, UT315, UT320, UT Hz U N I T Y / I Three-Phase Uninterruptible Power Systems UT10, UT15, UT0, UT0 60 Hz Planning and Installation Manual LTS-071D Copyright 1995, Best Power Technology, Incorporated IMPORTANT SAFETY INSTRUCTIONS

More information

LMI Watt Models

LMI Watt Models LMI 300-600 Watt Models Service Questions Call: 800-451-9423 INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed,

More information

Safety and General Information

Safety and General Information Safety and General Information Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety

More information

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY ELI-S-600 120 Volt ELI SERIES EMERGENCY LIGHTING INVERTERS Installation and Operation Instructions! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,

More information

Powerware Vdc Extended Battery Cabinet User s Guide.

Powerware Vdc Extended Battery Cabinet User s Guide. Powerware 9125 48 Vdc Extended Battery Cabinet User s Guide www.powerware.com FCC Part 15 Class A EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

Electrical Installation

Electrical Installation Electrical Installation Symmetra LX Tower UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

INSTALLATION & USER S GUIDE

INSTALLATION & USER S GUIDE INSTALLATION & USER S GUIDE NEMA 3R OUTDOOR EMERGENCY LIGHTING CENTRAL INVERTER 3KW 8KW SINGLE PHASE 4KW 8KW THREE PHASE 44 South Commerce Way, Bethlehem, PA 18017 18005265088 (610) 8683500 Fax: (610)

More information

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3 Atlantic Battery Systems 1065 Market Street Paterson, NJ 07513 Phone: (800) 875-0073 Fax: (973) 523-2344 sales@atbatsys.com www.atbatsys.com SOS1 SOS2 SOS SERIES Spares On Site Battery Cabinet Installation

More information

MODEL ELC-12/40-CVM-D BATTERY CHARGER

MODEL ELC-12/40-CVM-D BATTERY CHARGER NATIONAL RAILWAY SUPPLY MODEL ELC-12/40-CVM-D BATTERY CHARGER Installing, Operating and Service Instructions for the ELC-12/40-CVM-D Solid State Charger PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING

More information

Extended Battery Cabinet for Nfinity

Extended Battery Cabinet for Nfinity POWER PROTECTION Extended Battery Cabinet for Nfinity USER MANUAL TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................... 1 ELECTROMAGNETIC COMPATIBILITY.......................................

More information

Installation, Maintenance and Warranty Flat Plate Battery

Installation, Maintenance and Warranty Flat Plate Battery Installation, Maintenance and Warranty Flat Plate Battery Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or

More information

Foreword

Foreword Foreword Content 1. Summary 2. Safety instruction Safety Symbol Indication Attention Static discharge sensitive Electric shock Dangerous Indicate risk of serious injury or death or seriously damage the

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

INSTALLATION & USER S GUIDE

INSTALLATION & USER S GUIDE INSTALLATION & USER S GUIDE 1000W - 2800W SINGLE PHASE Series EM EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500

More information

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL 755-00020-DL 5/17/2017 2 755-00020-OEM R01 TABLE OF CONTENTS 1. Important Information About This Manual... 4 1.1 Manual Symbols...

More information

Installation Instructions and User Manual For

Installation Instructions and User Manual For Installation Instructions and User Manual For For 125VA/110W & 250VA/220W Mini-Inverter Power Systems ls: LG125S Surface Mounted Version LG125R Recessed Wall Mounted Version LG125T Recessed Ceiling T-Grid

More information

Galaxy VM. Battery Breaker Box Installation 09/

Galaxy VM. Battery Breaker Box Installation 09/ Galaxy VM Battery Breaker Box Installation 09/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred

More information

MODEL ELC-12/60-D BATTERY CHARGER

MODEL ELC-12/60-D BATTERY CHARGER *32198* NATIONAL RAILWAY SUPPLY Installing, Operating and Service Instructions for the 12/60 Solid State Charger MODEL ELC-12/60-D BATTERY CHARGER PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS

More information

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved. ENGLISH Installation and user manual SC 00 SC 70 SC 000 SC 00 SC 00G SC 70G SC 00G Copyright 03 EATON All rights reserved. Service and support: Call your local service representative Page IMPORTANT SAFETY

More information

Vehicle battery BATTERY WARNING SYMBOLS BATTERY CARE

Vehicle battery BATTERY WARNING SYMBOLS BATTERY CARE Vehicle battery BATTERY WARNING SYMBOLS On the battery label, the warning signs are as follows: BATTERY CARE No smoking, no naked flames, no sparks. The battery may emit explosive gas. Keep away from children

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input 208-240 Vac Output 208-120 Vac User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

Smart Charger 12-24V 60A, 1600W

Smart Charger 12-24V 60A, 1600W Smart Charger 12-24V 60A, 1600W Installation and User Manual Advanced Battery Chargers Table of contents Important SC 60A General SC60A 2 General 2 Installation 3 Operations 4 Safety Instructions 5 Troubleshooting

More information

CP900EPFCLCD User s Manual K

CP900EPFCLCD User s Manual K CP900EPFCLCD User s Manual K01-0000190-00 IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation

More information

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries RS-2046 Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries FOLLOW MANUFACTURER S PUBLISHED INSTRUCTIONS WHEN INSTALLING, CHARGING AND SERVICING BATTERIES.

More information

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Eclipse Plus VA UPS and Surge Suppressor User s Manual Eclipse Plus 250 250VA UPS and Surge Suppressor User s Manual Compact UPS/Surge Suppressor for Home Office or Small Office Use www.mgeups.com Notes Contents Thank You!.....................................................

More information

Installation and Operation Manual Nickel Iron MG300 Battery

Installation and Operation Manual Nickel Iron MG300 Battery Installation and Operation Manual Nickel Iron MG300 Battery Effective: July 2015 Nickel Iron MG300 Battery MG300 Encell Technology, Inc. Effective Date: July 2015 Encell Technology, Inc. NOTE: Photographs

More information

PR1000ELCD / PR1500ELCD User s Manual

PR1000ELCD / PR1500ELCD User s Manual PR1000ELCD / PR1500ELCD User s Manual K01-0000235-00 IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instructions. Please read and follow all instructions carefully during installation

More information

Rotary - TR/TRT/T5C - Installation

Rotary - TR/TRT/T5C - Installation Haas Technical Documentation Rotary - TR/TRT/T5C - Installation AD0005 Rev K Applies to machines built from: January, 2007 Scan code to get the latest version of this document Translation Available Rotary

More information

Uninterruptible Power Supply

Uninterruptible Power Supply AC/DC Din Rail UPS System Single Phase Input, Single Phase Output Uninterruptible Power Supply 600VA UPS System AC/DC Din Rail Mount Line Interactive (PWM): 600VA User Manual M1201_Din_Rail_AC-DC_600VA_Manual

More information

RAPID ROLLER OPERATOR S MANUAL. L&C ENTERPRISES - U.S.A, Inc N.75 Drive, Escanaba, MI OWNER S NAME MODEL

RAPID ROLLER OPERATOR S MANUAL. L&C ENTERPRISES - U.S.A, Inc N.75 Drive, Escanaba, MI OWNER S NAME MODEL RAPID ROLLER OPERATOR S MANUAL OWNER S NAME MODEL SERIAL NUMBER DATE OF PURCHASE L&C ENTERPRISES - U.S.A, Inc. 6652 N.75 Drive, Escanaba, MI 49829 906-786-1008 1-866-786-1009 LIMITED WARRANTY L&C Enterprises-USA,

More information

Battery Unit BHM60PC/BHM100PC Instruction Manual

Battery Unit BHM60PC/BHM100PC Instruction Manual Battery Unit BHM60PC/BHM100PC Instruction Manual For the use of UPS BH60PCW/BH100PCW This manual contains important information regarding the safe use of the BHM60PC/BHM100PC for the Backup Power Supply

More information

BR62 Battery Rack Installation, Operation, & Maintenance Manual

BR62 Battery Rack Installation, Operation, & Maintenance Manual BR62 Battery Rack Installation, Operation, & Maintenance Manual 8/28/2012 2 755-00046 R02 Copyright 2012 C&C Power, Inc. All rights reserved. C&C Power, Inc. 395 Mission Street Carol Stream, IL 60188 www.ccpower.com

More information

AIS and 40 kva 400 V. Site Preparation and Installation Manual

AIS and 40 kva 400 V. Site Preparation and Installation Manual AIS 3100 20 and 40 kva 400 V Site Preparation and Installation Manual www.apc.com AIS 3100 20 and 40 kva 400 V Site Preparation and Installation Manual www.apc.com IMPORTANT SAFETY INSTRUCTIONS SAVE THESE

More information

USER MANUAL. Uninterruptible power supply MODEL: 53965,

USER MANUAL. Uninterruptible power supply MODEL: 53965, USER MANUAL Uninterruptible power supply MODEL: 53965, 53966 www.qoltec.com Please check if the package contains: - UPS unit - Power cable (1 x SCHUKO) 1.2 m - User manual This UPS provides comprehensive

More information

BRAVER UPS. (Uninterruptible Power System) User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

Installation Power Management Unit Battery Cables and Battery Harness

Installation Power Management Unit Battery Cables and Battery Harness Installation Power Management Unit Battery Cables and Battery Harness Important Safety Messages SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation

More information

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply www.eaton.com/dxups USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply CONTENTS 1.Brief introduction 1 1.1 System and model description 1 1.2 Description of commonly used symbols

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP MOTIVE POWER BATTERIES

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP MOTIVE POWER BATTERIES PLEASE READ BEFORE PLACING BATTERIES IN SERVICE THESE INSTRUCTIONS TO BE SHIPPED WITH BATTERY AND TO BE DELIVERED TO USER INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP MOTIVE POWER BATTERIES

More information

PAC 600 PAC 800 PAC 800 comfort

PAC 600 PAC 800 PAC 800 comfort PAC 600 PAC 800 PAC 800 comfort Installation and User Manual Advanced Battery Chargers Table of contents POWERFINN PAC 600/800...2 General... 2 Installation...3 Operations... 4 Safety Instructions... 5

More information

BATTERY REPLACEMENT GUIDE

BATTERY REPLACEMENT GUIDE BATTERY REPLACEMENT GUIDE Uninterruptible Power Supply Models: SG2K-1T, SG2K-2T FALCONElectric Inc., 5116 Azusa Canyon Rd., Irwindale, California 91706, (626) 962-7770, Fax 626-962-7720, Email: sales@falconups.com

More information

SENS DC PowerCab 120 Installation, Operation, & Maintenance Manual

SENS DC PowerCab 120 Installation, Operation, & Maintenance Manual Installation, Operation, & Maintenance Manual Stored Energy Systems Packaged By: 1840 Industrial Circle C&C Power, Inc. Longmont, Co 80501 395 Mission Street www.sens-usa.com Carol Stream, IL 60188 Technical

More information

Installation Guide Smart-UPS On-Line Replacement Battery Module APCRBC140/APCRBC140J

Installation Guide Smart-UPS On-Line Replacement Battery Module APCRBC140/APCRBC140J Installation Guide Smart-UPS On-Line Replacement Battery Module APCRBC140/APCRBC140J Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install, operate,

More information

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810 5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8 Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9

More information

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL U P S Uninterruptible Power System Line-Interactive Network UPS 800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N OPERATING & MAINTENANCE INSTRUCTIONS 1206 SPECIFICATIONS Supply Voltage 230 Max Charge (Amps) 60 (cont) Max Boost (Amps) 400 Boost/Charge (Volts)

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 800 1100 2000 3000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 /

More information

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation

More information

Pulsar Evolution 2200/3000/3000 XL

Pulsar Evolution 2200/3000/3000 XL www.mgeups.com Pulsar Evolution 2200/3000/3000 XL Installation and user manual MGE UPS Systems 1660 Scenic Avenue Costa Mesa, CA 92626 (714) 557-1636 For service call 1-800-438-7373 www.mgeups.com IMPORTANT

More information

Rechargeable Garden Fountain

Rechargeable Garden Fountain Rechargeable Garden Fountain LLC Yeiser Research & Development Worldwide Patents Pending, YRD LLC PLEASE READ FIRST BEFORE RETURNING If you have any questions regarding assembly, parts or operating use.

More information

Spectron Industrial Series

Spectron Industrial Series 1300650 1300654 1300666 1300754 1300823 1300886 Table B Constant Value per Voltage System Wire Size (Maximum Voltage Drop 5%) System 6 Volt 12 Volt 24 Volt Wire Size #12 #10 #8 #6 #12 #10 #8 #6 #10 #12

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP AND TUBULAR-LM FAST CHARGE MOTIVE POWER BATTERIES

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP AND TUBULAR-LM FAST CHARGE MOTIVE POWER BATTERIES PLEASE READ THESE INSTRUCTIONS BEFORE PLACING BATTERIES INTO SERVICE. THESE INSTRUCTIONS MUST BE SHIPPED WITH THE BATTERY AND MUST BE DELIVERED TO THE USER. INSTALLATION AND OPERATING INSTRUCTIONS FOR

More information

Self-Testing Industrial Series

Self-Testing Industrial Series Series: AS-I (Maint.-Free) Self-Testing Industrial Series Emergency Lighting Equipment Instructions for INSTALLATION OPERATION SERVICE SPECIFICATIONS 1300650 1300654 1300666 1300754 1300823 1300886 Hubbell

More information

ES750 Battery-powered Cable Cutter

ES750 Battery-powered Cable Cutter INSTRUCTION MANUAL ES750 Battery-powered Cable Cutter 45380 with 120 V Charger 45381 with 220 V Charger Read and understand all of the instructions and safety information in this manual before operating

More information

Single-Point Watering Kit User s Guide

Single-Point Watering Kit User s Guide Single-Point Watering Kit User s Guide Contents 01 Kit Contents...................................3 02 Safety Instructions and Warnings.........................4 03 General Information and Precautions.......................

More information

USER MANUAL English / Español

USER MANUAL English / Español UPStation GXT LRT TM Battery Cabinet for use with the 1800-3000 VA UPS Units USER MANUAL English / Español IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself. Opening

More information

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Match 19 GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19 UPS. Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS Pump Sentry Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS The Pump Sentry is an innovative power station designed to operate your pump during a power outage. When properly installed, it will provide

More information

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS HEAVY DUTY BATTERY BOOSTERS / CHARGERS MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS 0707 Thank you for purchasing this CLARKE Battery Charger. These units are suitable for charging and

More information

Installing the CO 2 Cryogenic Oven Cooling Kit

Installing the CO 2 Cryogenic Oven Cooling Kit Installing the CO 2 Cryogenic Oven Cooling Kit Agilent 6850 Series II Network GC System Accessory G2625B This kit contains: Description Chassis 1 Chassis Cover 1 Ship kit: 1 Cooling coil 1 Coil bracket

More information

SEAUPS-III Uninterruptible Power Conditioning System. System Manual

SEAUPS-III Uninterruptible Power Conditioning System. System Manual SEAUPS-III Uninterruptible Power Conditioning System System Manual N9246 Hwy 80 South, Suite 7, Necedah, WI 54646 Tel: 608-565-5877 Fax: 608-565-5879 Email: sales@lpc-ups.com Website: www.lpc-ups.com BILS-10012

More information

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Eaton 9170 + Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4 USER S MANUAL ON-LINE 1K/2K/3KVA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. UPS OPERATION...... 12 6. TROUBLE

More information

Bulletin 1609 Industrial Uninterruptible Power Supply (Cat 1609-D)

Bulletin 1609 Industrial Uninterruptible Power Supply (Cat 1609-D) Installation Instructions Bulletin 1609 Industrial Uninterruptible Power Supply (Cat 1609-D) ATTENTION: Please read and save these instructions. This manual contains important instructions for the Bulletin

More information

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. XPC-EBP64 User & Installation Manual www.xpcc.com 2015. All rights reserved. (Rev 9/28/15) Table of Contents Introduction...5 Product Description...5 Extended Battery Pack Configurations...6 Safety Information...7

More information

IMPORTANT SAFEGUARDS

IMPORTANT SAFEGUARDS INSTRUCTION MANUAL NON-INTERRUPTIBLE AC INVERTER SYSTEM MODEL EAC FTM 350 FOR EMERGENCY LIGHTING POWER IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed,

More information

MP V 8A Electronic Smart Charger. Instruction and Information Manual

MP V 8A Electronic Smart Charger. Instruction and Information Manual MP7428 12V 8A Electronic Smart Charger Instruction and Information Manual In order to ensure correct and safe usage of your battery charger, you should read these instructions carefully. Please retain

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

POWERWARE User s Guide VA.

POWERWARE User s Guide VA. POWERWARE 3110 300 700 VA User s Guide www.powerware.com FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant

More information

INSTANT JUMPSTARTING POWER USER MANUAL. Copyright PowerStation, LLC All rights reserved MODEL: PS1100

INSTANT JUMPSTARTING POWER USER MANUAL. Copyright PowerStation, LLC All rights reserved MODEL: PS1100 INSTANT JUMPSTARTING POWER USER MANUAL Copyright PowerStation, LLC All rights reserved MODEL: PS1100 CONTENTS Warning Info 1 2 Introduction 3 Features 3 Getting to know your PS1100 4 5 Operation 6 Charging

More information

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1 Unit Installation and Service Manual A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping

More information

QPET, QPETXU Battery Chargers

QPET, QPETXU Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QPET, QPETXU Battery Chargers INTRODUCTION: The QPET line of chargers are designed for general purpose deep cycle batteries. They are an electronically

More information

Battery Capacity Analyzer

Battery Capacity Analyzer Battery Capacity Analyzer Owners Manual Aircraft Lead Acid Batteries P/N BC3000-0003 (ES1020) Rev. C REMEMBER: 1. LEAD ACID BATTERIES ARE THIRSTY. Always check electrolyte level using an aircraft quality

More information

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L GES L-Series Single Phase Input, Single Phase Output Uninterruptible Power Supply USER MANUAL Version 1.4 GES-801L, GES-102L, GES-152L, GES-202L, GES-302L Line Interactive (True Sine Wave): 800VA, 1000VA,

More information

OBE, OBEXU, ON BOARD Battery Chargers

OBE, OBEXU, ON BOARD Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBE, OBEXU, ON BOARD Battery Chargers INTRODUCTION: These chargers are designed for the permanent installation on battery powered vehicles

More information

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1 JUMP STARTER MODEL NO: JSM350 PART NO: 6239010 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS1117-ISS 1 INTRODUCTION Thank you for purchasing this CLARKE product. Please read this manual

More information

VRLA Batteries. Battery Installation And Start up Guide

VRLA Batteries. Battery Installation And Start up Guide TECHNICAL MANUAL 41-7525 VRLA Batteries 26-206 Ampere-Hour Capacity Battery Installation And Start up Guide (For Rack Mounted Systems) 41-7525/0514/CD www.cdtechno.com Table of Contents 12V VRLA Battery

More information

Limousin II User Manual

Limousin II User Manual Limousin II User Manual 600VA Uninterruptible Power Supply Single Phase Input, Single Phase Output M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc SAVE THESE SAFETY INSTRUCTIONS 1. This manual contains

More information

SP6. Automatic Battery Charger. Model

SP6. Automatic Battery Charger. Model Model SP6 Automatic Battery Charger OWNERS MANUAL PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE. This manual will explain how to use the charger safely and effectively. Please read and follow

More information

Technical Publications AWP. Operator's Manual. Fourth Edition, First Printing Part No

Technical Publications AWP. Operator's Manual. Fourth Edition, First Printing Part No Technical Publications AWP Operator's Manual Fourth Edition, First Printing Part No. 424 Operator s Manual Fourth Edition Important Read, understand and obey these safety rules and operating instructions

More information

OBAE, OBAEXU, ON BOARD Battery Chargers

OBAE, OBAEXU, ON BOARD Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S OBAE, OBAEXU, ON BOARD Battery Chargers INTRODUCTION: The OBAE line of chargers are designed for the permanent installation on battery powered

More information

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System USER MANUAL Blazer Vista 1000/1400/2000 Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for model Blazer Vista 1000/1400/2000

More information

USER MANUAL. GS Series Hybrid Inverter

USER MANUAL. GS Series Hybrid Inverter USER MANUAL GS Series Hybrid Inverter CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 IMPORTANT SAFETY INSTRUCTIONS... 1 General Precautions... 1 Personal Precautions... 2 INSTALLATION... 3 Unpacking

More information

AGM Series. Installation Manual AGM Series Modular Battery Systems

AGM Series. Installation Manual AGM Series Modular Battery Systems Installation Manual Modular Battery Systems Installation Manual Modular Battery Systems IMPORTANT! Read safety information first See Safety, Storage, Operating and Maintenance Manual The installation

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2

More information