1 AC UPS for Marine and Oil & Gas Applications YOUR POWER IN SAFE HANDS

2 AC UPS for Marine and Oil & Gas Applications The Secure Power range from Dale Power Solutions Contents 1 Introduction 2 The Erskine UP7000 AC UPS System 4 UPS Battery Capacity Testing 6 Safety & Maintainability 8 User Interface 9 Special Solutions 10 Specifications 11 Configurations 12 About Dale Keeping the power flowing.

3 The Erskine UP7000 AC UPS System Regen allows safer battery capacity tests Features 3 Range 5kVA to 500kVA 3 Custom solutions to meet the demanding requirements of major Marine and Oil & Gas and client specifications 3 Single or dual / parallel configurations 3 Galvanic isolation 3 High overload capability 01

4 AC UPS for Marine and Oil & Gas Applications The UP7000 raises the standard for secure power to critical controls and safety systems Reliability Proven and robust electronic controls of the UPS ensure the level of reliability and availability demanded. If required, dual or parallel configurations are available for the most critical applications. Power system friendly With near unity power factor and sinusoidal current drawn from the AC supply, the UP7000 pulse width modulated IGBT rectifier is the obvious choice to minimise harmonics and other power quality issues. Outstanding cost savings As the UP7000 can perform fully controlled battery discharge tests without the requirement of sending specialist trained engineers and suitable load banks to site, the lifetime operating cost savings can be significant with reduced personnel on board and their associated logistics. Special solutions To meet dedicated requirements and specifications of global offshore Marine and Oil & Gas clients, the AC secure power system is custom designed and configured. Custom designed systems can be configured from a comprehensive range of options available. Inherently safer design The UPS can perform a fully controlled discharge test of its battery with no need for maintenance personnel accessing potentially live circuits. Battery discharge energy is safely regenerated back onto the AC supply so eliminating potentially hazardous manual battery testing with load banks. User friendly With a large TFT colour touch screen operator panel the user interface provides immediate access to all important measured UPS operating values while the flow of power through the UPS is displayed on a multi-coloured mimic. Maintainability The UP7000 has been designed to allow safe and efficient servicing with all elements of the equipment readily accessible and properly shrouded. Regenerative capacity test simplifies maintenance, enhances safety and eases scheduling around ongoing operations. 02

5 MAINTENANCE BYPASS STATIC SWITCH BYPASS SUPPLY IGBT CHARGER INVERTER UPS AC OUTPUT AC INPUT SUPPLY ISOLATION TRANSFORMER ISOLATION TRANSFORMER BATTERY Elements of the UPS The UPS is configured from five main elements: Battery, IGBT rectifier, IGBT inverter, static bypass and maintenance bypass. The UPS output is controlled by an electronic static switch While in normal mode of operation, the inverter output supplies the load. Under fault or extreme overload conditions the fully rated static switch will transfer to the bypass supply to provide the maximum current for fault protection device clearance. The Maintenance Bypass provides the capability to isolate the static elements of the UPS and power the load from the bypass supply during UPS maintenance. Energy storage is provided by the battery The battery is generally of lead acid or nickel cadmium type as dictated by the application requirements. The battery autonomy is sized to the requirement of the UPS load including any design factors that may be required. The inverter generates a sinusoidal AC output from the DC bus The AC waveform has high static and dynamic regulation to cope with changing load conditions. A high overload ability maximises the load fault protection device clearance capability of the inverter feeding distribution breakers or fuses. IGBT power modules Both the rectifier and the inverter are based on pulse width modulated IGBT power modules providing high dynamic response and superior power quality with low harmonics. As required by Marine and Oil & Gas clients specifications, transformers are included in both the rectifier input and the inverter output to provide full galvanic isolation between the UPS battery, the AC supply and the AC output. The pulse width modulated IGBT rectifier operates in two modes: While in normal operation, the IGBT rectifier converts the AC mains supply to a regulated DC bus from which the battery is charged and inverter powered. The IGBT rectifier pulse width modulation operates with near unity input power factor and imposes minimal harmonics on the AC mains supply. While performing battery capacity testing, the IGBT rectifier operates as a grid synchronised inverter, taking current from the DC bus and regenerating the energy back onto the AC mains supply. The level of DC current regenerated is automatically controlled to achieve the required battery discharge test without requiring load banks

6 AC UPS for Marine and Oil & Gas Applications UPS Battery Capacity Testing Traditional UPS Battery Capacity Testing using load banks presents a range of issues which are particularly challenging in critical remote offshore applications. Energy Flow Traditional Battery Capacity testing Specialised Technician Intervention Required: 3 Switch UPS to Bypass 3 Isolate battery 3 Hook up trailing cable to load bank MAINTENANCE BYPASS Critical loads are not supported by battery during the test BYPASS SUPPLY RECTIFIER SUPPLY RECTIFIER INVERTER PLANT LOAD OFF-LINE STATIC BYPASS Battery energy converted to heat HVAC design must cope with TRAILING CABLE BATTERY LOAD BANK Operational Constraints Operations and maintenance must coordinate the battery test around any operational constraints and other work scopes. Logistics The load bank must be shipped offshore well in advance of the planned work, incurring rental costs and presenting a burden on logistics. Personnel Specialist trained and certified test engineers must be mobilised to site. This may require occupying valuable helicopter seats and offshore accommodation needed by other key personnel. Compromise Load In order to test the battery, the UPS will usually be switched to bypass or one half of dual redundant system disabled, compromising UPS availability and therefore critical plant load security during the test. HVAC Temporary ventilation may be required if the existing HVAC has not been designed to handle the heat output of the load bank. Live Working The engineer must isolate the battery and connect trailing cables to the load bank, manually configure the load bank for the required current and commence the discharge test, an inherently hazardous process on live equipment. 04

7 Regenerative UPS Battery Capacity Testing addresses these issues as the IGBT based rectifier/charger recovers the energy by regenerating current to the power grid. Energy Flow REGEN Battery Capacity testing Specialised Technician Not Required: 3 Do not switch UPS to Bypass 3 Do not isolate battery 3 Does not require trailing cable and load bank MAINTENANCE BYPASS BYPASS SUPPLY RECTIFIER SUPPLY RECTIFIER INVERTER PLANT LOAD Controlled regenerative power returned into AC supply ON-LINE Constant power or constant current battery discharge maintained regardless of plant load variations STATIC BYPASS Plant AC load maintained by battery and on-line inverter throughout the test Minimal compromise to load security BATTERY No increase in HVAC loading True on-line regen battery test The UPS does not get switched to maintenance bypass therefore critical plant loads remain supported by the battery and inverter which remain on line throughout the test. After the required capacity has been drawn from the battery and the DC voltage remains above the minimum value, the test is successful, the battery test data is stored in memory and the rectifier reverts to normal charge operation. Key safety and cost benefits: 3 Reduced need for live working 3 Fewer engineer-days on site 3 Less compromise to critical loads 3 Greater flexibility when to test 3 Logistics of load banks gone 3 HVAC issues avoided 3 Battery testing simplified Programmed battery test current is maintained by controlling energy fed back into the network while load current continues to be delivered through the inverter. Load banks are not required. Multiple scenarios are configurable with either constant current or constant power discharge while the test duration can be time-controlled, Ah-controlled or kwh-controlled. If necessary, the capacity test can also be programmed without energy recovery to the network. 05

8 AC UPS for Marine and Oil & Gas Applications Safety & Maintainability Features The UP7000 range of industrial AC UPS secure power systems meet the restricted access requirements to BS EN :2008. Accessibility of the UPS is ensured with ready access to power switching and control modules which are readily serviceable from front of the UPS without requiring removal of adjacent modules. Guarding minimises the risk during maintenance of unintentional bridging by conductive materials that might be present and circuits at hazardous voltages are located or guarded to make contact unlikely. The terminals are fully shrouded to protect against accidental contact. Electrical segregation provided between sections (rectifier, bypass, battery and inverter) to enable maintenance to be undertaken safely. Separate parts of the system can be isolated for maintenance without disrupting the load. Back feed is precluded and no shock hazard exists at the input terminals after interruption of the input power. The UPS is designed to cope with input voltage depressions and transients and non-linear loads that could be expected in Marine and Oil & Gas applications. Bypass static switching device is fully rated for both continuous and short circuit duties when it may be required to clear a load fault. 10ms 1000% In is provided as standard with the option of 1000ms 400% In available if requested. Maintenance bypass switch enables isolation of the static transfer switch from the bypass source and connects the output directly to the bypass source without interruption of the load power. High availability levels required for supporting high integrity control and safety systems is achieved by dual parallel redundant UPS. The individual rectifiers, bypasses and inverters all have independent control systems to make a single point of failure unlikely. In the event of a component failure, only one inverter will shut down. 06

9 Serial communications and diagnostics The UPS has the capability for connection to an Integrated Control and Safety System via fibre optic link, Modbus RS485, Profibus or Ethernet TCP/IP for remote network or web monitoring. The condition of individual sections including rectifier, inverter, and where included, battery monitoring system, is continuously monitored. Alarms and events can be logged. All measured values as displayed on the TFT screen are available over the serial link to enable trending of information including operating load and environmental conditions. Protection of the inverter Is achieved without relying on software control. The inverter power modules hardware inherently limits current under load fault conditions using on board hardware based protection. To allow discrimination of distribution protective devices, inverter short circuit capability up to 150% is standard with higher ratings available if requested. Electrostatically shielded full isolation transformers are provided on the input, bypass and output to allow independent grounding of the load and to provide protection against primary power surges and lightning transients in accordance with BS EN Distribution boards are designed to meet individual project requirements and comprise either fused switch disconnects, or circuit breakers. Selective coordination ensures faults on the outgoing ways can be cleared when operating on the inverter. The switching devices provide isolation in accordance with BS EN

10 AC UPS for Marine and Oil & Gas Applications User Interface The UPS user interface provides indication of measured UPS operating values. The settings can be changed and operating mode selected. Display measurements and features: 3 AC voltage, current and frequency of each power section and UPS output 3 Temperature of each power section 3 Battery voltage, current and Ah discharged 3 Rectifier and inverter DC currents 3 Comprehensive indication of alarms and status indications. 3 Event history capable of recording the previous 512 events 3 Access to UPS settings via a three level password system protecting the UPS configuration against unauthorised changes. The flow of power through the UPS is displayed on a multi-coloured mimic display with colour coded symbols. Measured values are displayed alongside the associated measurement points. 08

11 Special Solutions To meet dedicated client requirements and specifications the AC secure power system is custom designed and configured. Custom designed systems can be configured from a comprehensive range of options available. Typical options: System 3 Dual and parallel redundant schemes 3 Increased rectifier ratings for larger batteries 3 Different battery technologies 3 Charging temperature compensation 3 Bypass isolation transformers 3 Automatic voltage regulators 3 Charger and battery isolation 3 Customer specific distribution isolators, circuit breakers or fuses CONSTRUCTION 3 Battery enclosures or stands 3 Battery Fuse boxes or Ex breakers with ESD trips 3 Anti-condensation heaters 3 Panel lighting 3 Top or bottom cable entry 3 Custom paint specification 3 Increased enclosure ingress protection ratings 3 Larger enclosure sizes for more complex solutions ALARMS & COMMUNICATION 3 Remote communications 3 Analogue metering 3 Configurable remote alarms 3 Earth fault monitoring 3 Battery impedance 3 Battery voltage imbalance 3 Individual cell monitoring of cell voltage, impedance and temperature 09

12 AC UPS for Marine and Oil & Gas Applications Specifications Standard OptionS Comments AC Input Supply phase & voltage 380, 400, 415, Other on 400VAC +/- 10% request Supply wiring Three phase 4 wire Three phase with protective earth 3 wire Supply Frequency 50Hz +/- 5% 60Hz +/-5% Supply Power Factor 0.99 At full load at minimum load Supply current distortion 5% THDi At full load AC Output Phases 1-phase, 3-phase, 2-wire neutral with protective earth Output Voltage 220, 230, 240, 380, 400, 415, 254 VAC (1ph) 440 VAC (3ph) Output kva 5kVA to 120kVA 10kVA to 500kVA Up to 8 units can be operated in parallel Output Static voltage regulation +/- 1% 0-100% load variation Performance Dynamic voltage regulation +/- 4% 100% load step, 4ms recovery to within static limits Overload capability 150% for 1 minute Greater on request 125% for 10 minutes Greater on request 110% for 20 minutes Greater on request Short circuit capability 200% for 5 Sec Greater on request to EN pt 1 Waveform Distortion Sinusoidal <3% with linear load Crest factor (load current) <2.3 <3.0 Frequency 50Hz +/- 0.1% 60Hz +/-0.1% Load power factor range 0 lag to 0 lead Output power de-rated if power factor deviates from 0.8 lag General Operating temperature range -10 C to +40 C Storage temperature range Operating altitude -20 C to +70 C 0 to 1000m Operating humidity 10% to 90% RH Non condensing Tropicalisation Tropicalised PCB's. Safety BS EN EMC BS EN Enclosure Noise Level At 1M < 50 to 70 db(a) Depends on rating IP Rating IP31 IP41 or IP42 Cooling Natural or power module assisted Dependant on rating and load Dual Power Plant Fans Fans Supervision Terminals for Inter Enclosure Wiring Door Locks Padlockable Door Stays ACH Control by thermostat as standard, hygrostat optional Gland Plate Eye Bolts Cable Entry Bottom Top Option for top cable entry through top of bypass panel only Wiring Idents Wiring Crimps Earth Bus Bar Labels External labels screw fixed Document Wallet Cabinet Lamp Rear Door Access LSZH Cabling Enclosure finish RAL7035 Other on request Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. 10

13 Configurations Standard Option Comments System Single Dual (2 x Single) Parallel Redundant Rectifier Type IGBT Standard dual rectifier & inverter, single bypass Other configurations available Rectifier Input Circuit Breaker MCCB With thermal & magnetic protection Padlockable in both positions Input Transformer Isolating With taps to suit different input voltage options Input soft start Limits input inrush current to transformer and rectifier Input On/Off Switch On TFT Display DC Earth Fault Boost Charge Facility For Ni-Cad batteries only. Disabled for VRLA batteries Diesel Generator Bypass/Static Switch Bypass Static Switch Location Depends on rating Bypass Enclosure Enables isolation of remainder of system for maintenance Bypass Transformer Phase-Neutral, Phase-Neutral or Arrangement of phases and without bypass Phase-Phase, with taps to suit application transformer bypass transformer input and output voltages Voltage Stabiliser Bypass Input Circuit Breaker MCCB Thermal & magnetic protection. Padlockable in both positions Bypass Switch MCCB type isolator 3 way rotary Padlockable in all positions Bypass Static Switch Fast Acting Fuse Link Fit link when fuse not in circuit Input Protection Overload Condition % 10ms Battery Battery Protection Internal MCCB Internal MCCB Type isolator interfaced with external device. (Exd if required) Vent Fan Fail Boost Inhibit NTC Reverse polarity protection Regen Battery Test Voltage Depression Battery Test Battery Load Test Terminals Battery Bus Tie Black Start Facility Manual Auto Blocking Diode Inverter Type IGBT PWM 1ph IGBT PWM 3ph Padlockable in both positions Can be interfaced with ESD signal. Output Isolating Transformer With taps to suit different input voltage options AC Earth Fault Input On/Off Switch On TFT Display UPS Output Load Switch Crest Factor <2.3 <3.0 Overload Condition 1 150% 1min Greater on request Overload Condition 2 125% 10 min Greater on request Overload Condition 3 110% 20 min Greater on request Short circuit capability 200% for 5 Sec Greater on request to EN pt 1 Options Remote contacts Load on Inverter Load on Bypass Battery Discharging Battery Low Volts Bypass Mains Failure Common UPS Alarm Optional 8-way relay card relay card with configurable contact assignment Serial Interfaces Choice of SNMP, Modbus RS485, Profibus, Ethernet TCP/IP, Fibre AC Distribution Specific requirements to be confirmed per project: e.g. Double or Triple Pole MCB's Bus Tie, MCB Common Trip Incomer Switch 11

14 AC UPS for Marine and Oil & Gas Applications Dale Power Solutions Delivering secure back-up power across the globe Established since 1935, Dale Power Solutions has become a global leader in bringing technology and engineering together to create innovative solutions, protecting critical power supplies for customers through our standby power systems. With an annual turnover in excess of 30million, it is through Dale Power Solutions commitment to excellence, combined with our mission to deliver outstanding client service has earned Dale Power Solutions its prestigious reputation it enjoys today as one of the world's most trusted providers of standby power solutions. Dale Power Solutions provides a comprehensive and bespoke design capability service to our customers, taking initial concepts through design, project management, manufacturing, installation and commissioning processes, followed by complete maintenance and servicing on a worldwide basis to more than 8,000 generators and UPS systems. Our professional structure, financial strength and the necessary quality assurance, health and safety, and product accreditations meet the demands of the world's most discerning clients. These accreditations include: Proud of our pedigree proud to be your partner. 12

15 AC UPS for Marine and Oil & Gas applications Critical power continuity guaranteed

16 Dale Power Solutions Ltd Head Office, Factory 1, Scarborough Salter Road Eastfield Industrial Estate Scarborough North Yorkshire YO11 3DU Tel : produced by adverset media solutions limited Factory 2, Filey Tel : Aberdeen BRANCH Tel: London CITY BRANCH Tel: Middle EasT BRANCH Tel: Your power in safe hands

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

Liebert. FP 50Z kva

Liebert. FP 50Z kva Liebert FP 50Z 5 250 kva Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at a lower cost when search and social

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

Industrial PFC UPS System

Industrial PFC UPS System Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41

More information

D Series: UPS UPTO - 300KVA - Three / Three Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction

More information

Industrial Chargers and

Industrial Chargers and Industrial Chargers and DC Systems SPR - Single Phase Rectifier TPR - Three Phase Rectifier 12V 250V 5A 1000A Designed for all Industrial applications Oil & Gas, Petrochemicals Offshore, Onshore, Pipelines

More information

PowerValue 11/31 T kva

PowerValue 11/31 T kva Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power

More information

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME on-line UPS The series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models and uses

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

YOUR POWER IN SAFE HANDS. E Series UPS

YOUR POWER IN SAFE HANDS. E Series UPS E Series UPS YOUR POWER IN SAFE HANDS E Series UPS Secure Power The E Series UPS range from Dale Power Solutions Contents 1 Introduction 2 E-Series UPS Power Matrix 4 E200 Series 1 3kVA 6 E200 Series 6

More information

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva Power Safety Protect 8. Industrial UPS Protect 8.31 Single Phase output 10 kva 120 kva Protect 8.33 Three Phase output 10 kva 120 kva 400 V AC input 220 V DC The Building Block UPS Engineering is our Business

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01

More information

Technical Data Sheets

Technical Data Sheets GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

MGE TM Galaxy TM 7000

MGE TM Galaxy TM 7000 MGE TM Galaxy TM 7000 Power efficiency for business continuity 160/200/250/300/400/500 kva > Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Medium to Large

More information

MKN-DSP SERIES - THREE PHASE

MKN-DSP SERIES - THREE PHASE Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

Master Plus kva

Master Plus kva Local Area Networks (LAN) ServerS Data Centers Telecommunication devices e-business (Servers Farms, ISP/ASP/POP) Industrial Processes Industrial PLCs Electromedical Devices Emergency Devices (lights/alarms)

More information

AME. Rectifier - Battery charger. Industrial applications: Key features:

AME. Rectifier - Battery charger. Industrial applications: Key features: Rectifier - Battery charger AME VRLA batteries, flooded battery or Ni/Cd with output voltage from 24, 48, 110, 220 Vdc up to 150A Industrial applications: Oil&Gas (Petrochemicals Offshore, Onshore, Pipelines);

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 100 &120 PurePulse TM SG Series 60 & 80 PurePulse SGSE_060-120_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL Local Area NETWORKS (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

POWER kva

POWER kva TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power

More information

Technical data sheets

Technical data sheets GE Digital Energy Technical data sheets Digital Energy Uninterruptible Power Supply Series UPS 6-10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41

More information

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC) TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)

More information

Illuminator Series CR NEMA 3R

Illuminator Series CR NEMA 3R Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the

More information

Three Phase UPS Systems

Three Phase UPS Systems Three Phase UPS Systems Range: 10 to 500kVA MEDICAL PLASTIC AUTOMOBILE PULP & PAPER PACKAGING Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE

More information

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase SUPREME on-line UPS The Supreme series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models

More information

POWER kva

POWER kva +44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw

More information

Master DIALOG INDUSTRY RANGE

Master DIALOG INDUSTRY RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs Emergency devices (lights/alarms) Electro-medical devices Telecommunication devices Industrial applications

More information

Tower Electronic Systems

Tower Electronic Systems 3300 UPS Instruction Manual AUGUST 2005 CONTENTS 1.0 INTRODUCTION 1.1 General description 3 1.2 UPS building blocks 3 1.2.1 Boost converter 3 1.2.2 Inverter 3 1.2.3 Static transfer switch 3 1.2.4 Battery

More information

PowerPro three phase UPS technical data

PowerPro three phase UPS technical data PowerPro three phase UPS technical data General Specification Model RM/RT10 RM/RT15 RM/RT20 RT30 RT40 RT60 RT80 RT100 RT120 RT160 UPS type Power rating kva 10 15 20 30 40 60 80 100 120 160 kw 8 12 16 24

More information

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 400/500 kw With eboost Technology TLE Series UPS 400/500 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power

More information

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work Digital Energy Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91

More information

Technical Data Sheets

Technical Data Sheets Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply

More information

MGE TM Galaxy TM 7000 GFC

MGE TM Galaxy TM 7000 GFC MGE TM Galaxy TM 7000 GFC Grid Frequency Converter (GFC) for Shore Connection solution 500 kva Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Shore Connection

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TM SG Series 200-250 - 300 PurePulse CE S3 TM SG Series 160 PurePulse CE S3 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication

More information

Technical Specification SENTINEL PRO

Technical Specification SENTINEL PRO Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES

More information

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out) TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5

More information

60 to 160 kva.

60 to 160 kva. 60 to 160 kva www.borri.it Low TCO, efficient and compact solution for supplying reliable uninterrupted quality power to all critical applications in networking and small to medium datacenter, health,

More information

Aurora Single Phase Emergency Lighting Inverters

Aurora Single Phase Emergency Lighting Inverters Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available

More information

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM PowerLine DPA 20 120 kva Full power for industrial applications PowerLine DPA 20 120 kva Full power for industrial applications 2 ABB UPS SYSTEMS POWERLINE

More information

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99 80-125 kva/kw E Three-Phase Double-Conversion On-Line Full Four Year Warranty www.stacoenergy.com Up to 99% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front,

More information

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery

More information

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical

More information

POWERTRONIX QUASAR 5-40 KVA

POWERTRONIX QUASAR 5-40 KVA POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251

More information

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems Liebert Hipulse E The High-ECO-Availability UPS AC Power Systems We re Emerson Network Power, backed by Emerson, a global company that brings technology and engineering together to provide innovative solutions

More information

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE DATACENTER E-MEDICAL INDUSTRY TRANSPORT EMERGENCY VFI TYPE ONLINE Master MPS 3:1 3:3 10-100 kva 10- kva 4 SmartGrid ready f lywheel compatible Supercaps UPS Service 1st start HIGHLIGHTS Efficiency Control

More information

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems. SENTRY HPS HM/HT provides maximum protection for vital mission-critical networks, security applications (electro-medical) and industrial applications thanks to its outstanding mechanical and electrical

More information

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw DELPHYS GP Green Power 2.0 range 160 to 1000 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

INTELEPOWER CX COMMUNICATIONS SYSTEMS

INTELEPOWER CX COMMUNICATIONS SYSTEMS INTELEPOWER CX COMMUNICATIONS SYSTEMS INTELEPOWER CX COMMUNICATIONS SYSTEMS Intelepower DC UPS - CX Range Designed For Communications The demands for quality power in communication applications are placing

More information

3ph UPS NS3000 series kVA

3ph UPS NS3000 series kVA 3ph UPS UPS NS3000 SERIES NS3000 series 10-120kVA UPS NS3000 SERIES Main concepts in NS3000 design Last Generation 3ph UPS Features Fast and Simplified Intervention Range and Mechanical features NS3000

More information

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE DATACENTRE E-MEDICAL INDUSTRY Master MPS TRANSPORT EMERGENCY VFI TYPE ONLINE Tower 4 3:1 3:3 10-100 kva 10-200 kva SmartGrid ready Flywheel compatible Supercaps UPS Service 1st start HIGHLIGHTS Efficiency

More information

Green Power 2.0 MASTERYS GP

Green Power 2.0 MASTERYS GP Green Power 2.0 MASTERYS GP 60 to 120 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

EMEX Power Modular AC/AC central power supply system

EMEX Power Modular AC/AC central power supply system 90 EMERGI-LITE EMERGENCY LIGHTING & CENTRAL POWER SUPPLY SYSTEMS Modular AC/AC central power supply system The inverter and charger modules utilise solid state electronics of the highest reliability to

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

Emergency Lighting Products Limited

Emergency Lighting Products Limited Modern businesses are under pressure to maximise the (sales) revenue per square metre of floor space. The CEN-Power 'Compact' series of static inverters has been designed to significantly reduce the amount

More information

MASTERYS IP+ 10 to 80 kva

MASTERYS IP+ 10 to 80 kva MASTERYS IP+ 10 to 80 kva OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application. the information

More information

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS Tender Paper TECHNICAL SPECIFICATIONS FOR 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS Contents 1. General 2. Tender submission requirements 3. Environmental

More information

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity DATACENTER E-MEDICAL INDUSTRY TRANSPORT EMERGENCY BMPM/ BMPT Series VFI TYPE ONLINE Tower 4 3:1 10-100 kva 3:3 10-200 kva SmartGrid ready Flywheel compatible Supercaps UPS Service 1st start HIGHLIGHTS

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company imagination at work QUITO: Elia Liut N45-26 y Edmundo Chiriboga Telf:

More information

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004 SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004 Applications Computer and Data Centers Server Farms Process Control Broadcasting / SAT Systems Radar control installations Air traffic control

More information

TLE Series UPS 750/1000 kw With eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology TLE Series UPS 750/1000 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

.3 Section Waste Management and Disposal.

.3 Section Waste Management and Disposal. Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section

More information

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power EMEX Power EMEX Power Modular AC/AC Central Battery System EMEX Power EMEX Power Modular AC/AC Central Battery System System design The EMEX Power inverter and charger modules utilise solid state electronics

More information

Master Plus kva

Master Plus kva LOCAL AREA NETWORKS SERVERS DATA CENTERS TELECOM MUNICATION DEVICES (Servers Farms, ISP/ASP/POP INDUSTRIAL PROCESSES INDUSTRIAL PLCS MEDICAL DEVICES EMERGENCY DEVICES ights/alarms Master Plus 100- kva

More information

Food power. ABB s rugged UPS PowerLine DPA ensures food and beverage production facilities keep running

Food power. ABB s rugged UPS PowerLine DPA ensures food and beverage production facilities keep running 44 ABB review 2 16 Food power ABB s rugged UPS PowerLine DPA ensures food and beverage production facilities keep running DIANA GARCIA For many industries such as food and beverage, the consequences of

More information

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE DATACENTER E-MEDICAL INDUSTRY TRANSPORT EMERGENCY VFI TYPE ONLINE Master MPS 3:1 3:3 10-100 kva 10- kva 4 SmartGrid ready Flywheel compatible Supercaps UPS Service 1st start Highlights Efficiency Control

More information

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99 65-500 kva Full Two Year Warranty Three-Phase Double-Conversion On-Line Up to 98% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front, top or bottom access, so

More information

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE DPP/DPP Digital Process INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE PROVIDING CONTINUITY OF ELECTRICAL POWER DPP/DPP DIGITAL PROCESS POWER Industrial Pulse Width Modulated

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS 40, 60, 80 kva (three phase input and output) GENERAL DATA Output Rated Power kva 40 60 80 Output Power Factor 0.8 Topology Technology Construction Parallel Configuration Redundant

More information

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting

More information

ConceptpowerTM Modular kVA

ConceptpowerTM Modular kVA TECHNICAL SPECIFICATIONS ConceptpowerTM Modular 10-15-20-30-40kVA Uninterruptible Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI Classic-Line 10-40kVA Gemini-Line 10-30kVA

More information

QUEENSLAND URBAN UTILITIES

QUEENSLAND URBAN UTILITIES DOCUMENT NO : EQUIPMENT NO : PREPRED : CHECKED : PPROVED : SHEET NO : 1 of 6 GENERL 1 Battery Charger DCC Inverters 3 DCDC Converters 4 System Design Life (other than batteries) Years 5 Battery Design

More information

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase Local Area Networks (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com

More information