1 Operating Instructions Turbine Meter turbodos ProMinent Please completely read through operating instructions! Do not discard! The operator shall be liable for any damage caused by installation or operating errors! Part No ProMinent Dosiertechnik GmbH Heidelberg Germany BA TD /09 GB

2 Corporate information Corporate information: Operating Instructions Turbine Meter turbodos ProMinent Dosiertechnik GmbH, 2008 ProMinent Dosiertechnik GmbH Im Schuhmachergewann Heidelberg Germany Phone: Fax: Technical changes reserved. Printed in Germany Page 2 ProMinent

3 Inhaltsverzeichnis Page General User Information About this Product Safety Identification of the Notes on Safety Proper Use Storage and Transport Design and Function Design Function Installation Installation, hydraulical Installation, electrical Technical Data Performance Data Electrical Data Dimensions Materials Used Maintenance Disposal Order Information... 8 Annex... 9 ProMinent Page 3

4 General User Information General User Information Please read through the following user guidelines! Familiarity with these points ensures optimum use of the operating instructions. Key points in the text are indicated as follows: Enumerations Instructions Working guidelines: NOTE A note provides important notes for the correct functioning of the unit or is to facilitate your work. and notes on safety identified by pictographs (see Chap. 2) Page 4 ProMinent

5 About this Product 1 About this Product The turbine meters turbodos are designed to meter the flow rate of drinking water for controlling systems. 2 Safety 2.1 Identification of the Notes on Safety The following terms are used in the present operating instructions to indicate the various severity levels of the danger: WARNING Characterizes a possibly hazardous situation. Your life is in danger or there is a danger of serious injury if these notes are disregarded! CAUTION Characterizes a possibly hazardous situation. There is a danger of slight or minor injury or damage to property if these notes are disregarded! The following warning signs are used in the present operating instructions to indicate different types of danger: Warning of danger area Warning of hazardous electrical voltage 2.2 Proper Use The turbine meters turbodos are designed to meter the flow rate of waters similar to drinking water for controlling systems. All other uses or modifications are prohibited. The turbine meters turbodos are not designed for applications which require a drinking water approval. The turbine meters turbodos are no flow meters tested according to the German Weights and Measures Act. They are not designed to meter domestic water consumptions. Only use the turbine meters turbodos as described in the operating instructions for Ultromat. The turbine meters turbodos may only be assembled and installed by qualified personnel. You are obliged to observe the information in the operating instructions on the various life phases of the system! 3 Storage and Transport Only store and transport the turbine meter turbodos in a suitable packaging! Permissible storage and transport temperature: -10 C bis +70 C ProMinent Page 5

6 Design and Function 4 Design and Function 4.1 Design The turbine meter turbodos consists of a measuring tube (1), the turbine (2) with integrated solenoid, a sensor with the evaluation electronics (3) Measuring pipe 2 Turbine 3 Sensor with evaluation electronics (fluid gauge chamber) Fig. 1: Section of turbine meter turbodos 4.2 Function The water which flows through the water meter moves the turbine wheel. The sensor detects the turbine cycles via the solenoid in the turbine wheel. The evaluation electronics converts these pulses into a transistor contact output signal (make contact). Page 6 ProMinent

7 Installation / Technical Data 5 Installation 5.1 Installation, hydraulical CAUTION When installing, please note the flow direction of the turbine meter turbodos - see arrow at the housing! Thoroughly remove any foreign material from the pipe and the turbine meter turbodos. Install the turbine meter turbodos according to the generally acknowledged rules of technology! Install the turbine meter turbodos in the water pipe via the screw connections. Do not forget the gaskets! 5.2 Installation, electrical WARNING Risk of electric shock! High electrical voltage may exist in the control cabinet of the system! The electrical installation of the turbine meter turbodos may only be performed by a qualified electrician! Carry out the electrical installation of the turbine meter turbodos in accordance with the terminal connection diagram in the annex. 6 Technical Data 6.1 Performance Data Lower operating limit 0.07 m 3 /h Upper operating limit 22 m 3 /h Linearity range 2 % m 3 /h Pulses turbine (input evaluation electronics) 67.5 Imp/l Pulse spacing l/imp Operating pressure, max. 10 bar Operating temperature 30 C Pressure loss at upper operating limit 0.50 bar Flow rate at 0.2 bar pressure loss 13 m 3 /h 6.2 Electrical Data NPN version for ULSa Electrical connection Power consumption Minimum contact duration at upper operating limit Load resistance between signal and VCC 12 VDC 23 ma 2.4 ms kω PNP version for PLC Electrical connection Power consumption Minimum contact duration at upper operating limit Load resistance between signal and VCC 24 VDC 18 ma 2.4 ms kω ProMinent Page 7

8 Technical Data / Maintenance / Disposal / Order Information 6.3 Dimensions Connecting thread DIN ISO 228-G Overall length without screw fitting Overall length with screw fitting 1 1/2 A 135 mm approx. 250 mm 6.4 Materials Used Measuring pipe (1) Turbine (2) Turbine axis Turbine bearing brass PPE carbide sapphire 7 Maintenance The turbine meter turbodos is maintenance-free. 8 Disposal CAUTION Please observe the current applicable relevant local regulations - specifically concerning electronic waste! 9 Order Information NPN version for ULSa Order no. turbodos complete with NPN output, 12 VDC and 6 m cable Fluid gauge chamber for turbodos with NPN output, 12 VDC and 6 m cable PNP version for PLC turbodos complete with PNP output, 24 VDC and 6 m cable Fluid gauge chamber for turbodos with PNP output, 24 VDC and 6 m cable Page 8 ProMinent

9 Annex Annex Wiring diagrams NPN output (for ULSa) 12 VDC green Input ULSa Signal brown NPN Puls Sensor GND white PNP output (for PLC) 24 VDC green 1 k PNP brown Puls Sensor Signal Input PLC GND white ProMinent Page 9

10 Annex Terminal Connection Diagram green operating voltage white signal mass brown contact output Page 10 ProMinent

11 Annex Manufacturer s Declaration ProMinent Page 11

12 Addresses and delivery through manufacturer: ProMinent Dosiertechnik GmbH Im Schuhmachergewann Heidelberg Germany Tel.: Fax: Technische Änderungen vorbehalten. Printed in Germany

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions!

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions! Rev. 1.8 Operating Manual for Pressure Sensors 97PA-21x-xxx page 1 of 6 Operating Manual Pressure Sensors Article numbers: 97PA-21G-10 97PA-21G-50 97PA-21Y-5 97PA-21Y-25 97PA-21Y-160 97PA-21Y-400 NOTE

More information

Meter FMT II. Operating manual. original operating manual. Translation of the

Meter FMT II. Operating manual. original operating manual. Translation of the Operating manual Meter FMT II Item-No.: 253590000, 253590001, 253590003, 253590004, 253590006, 253590007, 253590008, 253590009, 253590010, 253590011, 253590012, 253590013, 253590020, 253590030, 253590031,

More information

FTB 372 Series Axial Turbine Flow Meter

FTB 372 Series Axial Turbine Flow Meter . FTB 372 Series Axial Turbine Flow Meter - 2 - Series FTB 372 Series FTB 372 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 6 2 Safety instructions...

More information

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25 Installation Instruction Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25 Table of contents Page 1 Function of Turbotron 1 2 Safety instructions 2 3 Important notes and requirements

More information

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor FlowX3 F3.20 is a paddlewheel flow sensor suitable for system at high pressure and at critical temperature. F3.20 is designed for use with every kind

More information

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual Flowmeter Ultrasonic Flow Metering / Dosing Device Operating Manual Read the user's manual carefully before starting to use the unit or software. Producer reserves the right to implement changes without

More information

MWF+ Application. Types Available. Average temperature sensor. Datasheet

MWF+ Application. Types Available. Average temperature sensor. Datasheet MWF+ Average temperature sensor Datasheet Subject to technical alteration Issue date: 28.03.2018 A002 Application Duct averaging temperature sensor in enclosure USE-S for measuring the average temperature

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information

Elektric actuator MC50/24-C

Elektric actuator MC50/24-C Issue 2014-04-29 Operating manual 3.10-TA.150-15-EN Elektric actuator for KTM512, KTH512 DN15-50 Application Elektric actuator for 3-point or modulating controllers in heating systems. Positive connection

More information

Electrical linear actuator with safety function MC100FSR/24

Electrical linear actuator with safety function MC100FSR/24 Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Electrical linear actuator with safety function Application Linear actuator with automatic coupling and safety function for fine stroke adjustment of

More information

Supplementary instructions Sigmas with hygienic pump head

Supplementary instructions Sigmas with hygienic pump head Supplementary instructions Sigmas with hygienic pump head EN Two sets of operating instructions are required for the safe, correct and proper operation of the metering pumps: this set of supplementary

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

WATERFLUX 3070 Quick Start

WATERFLUX 3070 Quick Start WATERFLUX 3070 Quick Start Battery powered electromagnetic water meter Electronic Revision ER 4.3.0_ up to ER 4.3.4_ (SW.REV 4.2.2_ up to 4.2.5_) KROHNE CONTENTS WATERFLUX 3070 1 Safety instructions 4

More information

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur Water flow rate transmitter Wasser-Durchfluss-Transmitter Transmetteur de débit d eau Operating Instructions Bedienungsanleitung Manuel utilisateur We reserve the right to make technical changes without

More information

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 AB AXIS INDUSTRIES ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF2V01 KAUNAS Contents Page SAFETY INFORMATION... 1. APPLICATION FIELD... 2. TECHNICAL

More information

Support T10552 T10595 T40386

Support T10552 T10595 T40386 T10552 T10595 T40386 en-gb 7 T10552 T10595... 1 General Information Product name: Product type: Product number: Weight: Max. load capacity: Static test coefficient: 3.0 Intended Use: Load holding device

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Electrical linear actuator with safety function MC100FSR/230

Electrical linear actuator with safety function MC100FSR/230 Issue 2013-05-24 Operating manual 3.10-TA.210-10-EN Electrical linear actuator with safety function Application Linear actuator with automatic coupling and safety function for fine stroke adjustment of

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions Temposonics Magnetostrictive Linear Position Sensors Table of contents. Introduction...3 2. Safety instructions...4 2. Intended use...4 2.2 Forseeable misuse...4 2.3 Installation, commissioning and operation...5

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation Handheld calibration tool / Handheld cleaning tool Tragbares Kalibrierwerkzeug / Tragbares Reinigungswerkzeug Outil d'étalonnage portatif / Outil de nettoyage portatif Operating Instructions Bedienungsanleitung

More information

Hot Runner System Instruction Manual

Hot Runner System Instruction Manual Hot Runner System Instruction Manual Rev1.4 11 / 2011 RK Introduction Dear Customers, Thank you for purchasing a Synventive Hot Runner System. Our objective is to provide you with a product that is a good

More information

Assembly and operating Instructions. Bypass Flow Meter DST

Assembly and operating Instructions. Bypass Flow Meter DST Assembly and operating Instructions Bypass Flow Meter 2 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions and exemption from liability... 3 2.3. Intended

More information

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE Operating instructions FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE 1547440000 IE-CL240W-PP-REMOTE 1547450000 Technical service: freecon.contactless@weidmueller.com Weidmüller

More information

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Braking Module / Braking Resistor SINAMICS G130 04/04 Contents Contents 1 Safety Information 1-1 2 General 2-1 3 Mechanical Installation 3-1 4 Connection 4-1

More information

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet AKF10+ Duct-/Immersion temperature sensor Datasheet Subject to technical alteration Issue date: 26.03.2018 A002 Application Duct/Immersion sensor for measurement of air temperature and other gaseous mediums

More information

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 , IECEx EPS 16.0030X Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet AKF10+ Duct-/Immersion temperature sensor Datasheet Subject to technical alteration Issue date: 04.07.2018 A005 Application Duct/Immersion sensor for measurement of air temperature and other gaseous mediums

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES A S E R I E S Catalogue 001 Directly operated solenoid valves Series A / way, 3/ way monostable, stable (with magnetic memory) Ports M5, G1/8, cartridge ø 4 The Series A solenoid valves are of the directly

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Infocal 9 Energy calculator for heating and cooling applications

Infocal 9 Energy calculator for heating and cooling applications Installation Guide Infocal 9 Energy calculator for heating and cooling applications www.danfoss.com 2 Danfoss Energy Meters 2018.08 VU.IG.N2.02 1. Installation 1.1. Preparation Only qualified personnel

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

Pneumatic grease pump 50:1 and grease supply system

Pneumatic grease pump 50:1 and grease supply system Pneumatic grease pump 50:1 and grease supply system 03 591 A411 GB G Operating instructions for Pneumatic grease pump 50:1 Contents 1. General Information 2 1.1 Usage Stipulations 2 1.2 Construction &

More information

standards based cylinder DNCI Operating instructions e [ ]

standards based cylinder DNCI Operating instructions e [ ] standards based cylinder DNCI en Operating instructions 8072823 2017-05e [8072825] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

Red/green-LED for switching state indication (dyn.) Yellow LED for dirt accumulation indication

Red/green-LED for switching state indication (dyn.) Yellow LED for dirt accumulation indication FLB Series FLB-F2-...-HS (High Speed) - High switching frequency (10kHz) - Integrated electronics - High sensitivity (adjustable via 5-step switch) - Pulse length adjustable via 5-step switch - Dynamic

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15 17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

Digital Pressure Regulator Sentronic PLUS Series 614

Digital Pressure Regulator Sentronic PLUS Series 614 Digital Pressure Regulator Sentronic PLUS Series 14 Installation manual IM149-/R01 CONTENTS 1. Description... 1.1 Catalogue number... 1. Operating elements...4 1. Operating modes...4. Electrical connection...5.

More information

Operating Instructions ProMinent Sigma/ 2 S2Ba (Basic Type) S2Ca (Control Type)

Operating Instructions ProMinent Sigma/ 2 S2Ba (Basic Type) S2Ca (Control Type) Operating Instructions ProMinent Sigma/ 2 S2Ba (Basic Type) S2Ca (Control Type) ProMinent STOP START S2Ba S2Ca S2Ba S2Ca Please enter the identity code of the device here. Two sets of operating instructions

More information

Safety Sensor CSS 180 Product Information

Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions , IECEx EPS 16.0053X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

Flexible storage and handling with ProMinent The right products for storage and transfer of liquid chemicals

Flexible storage and handling with ProMinent The right products for storage and transfer of liquid chemicals Flexible storage and handling with ProMinent The right products for storage and transfer of liquid chemicals Printed in Germany, PT PM 056 09/06 GB MT06 01 04/05 GB Storage and transfer Storage tanks Our

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

INSERTION flow sensor for continuous flow measurement

INSERTION flow sensor for continuous flow measurement INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)

More information

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer A company of ThyssenKrupp Elevator ThyssenKrupp Aufzugswerke Operating Manual Oil buffer OPERATING MANUAL Printer s imprint All rights reserved. Copyright by: THYSSENKRUPP AUFZUGSWERKE GMBH P.O. box 23

More information

MANUAL NO E1.2 Published in Dec.2004 Revised in Aug LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL

MANUAL NO E1.2 Published in Dec.2004 Revised in Aug LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL MANUAL NO. 20405E1.2 Published in Dec.2004 Revised in Aug. 2007 LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL LF SERIES FOREWORD For safe operation... Thank you for using our LS

More information

Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4

Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4 Operating instructions Metering pumps Hydro/ 2, Hydro/ 3 and Hydro/ 4 Two sets of operating instructions are required for the safe, correct and proper operation of the ProMinent Hydro metering pumps: These

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE.

S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE. S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE GAMMA/ L THE DOSING PUMPS WITH INTELLIGENCE. M ORE CONTROL VERSATILITY LESS

More information

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel Gas-Insulated Switchgear GHA Gas-Insulated Switchgear Switchgear extension and replacement of a panel During this work, essential parts of the switchgear remain in operation No. AGS 535 066-01 Edition

More information

Sentronic LP IO-Link CLASS A 617 Series. 617 Series IO-Link CLASS A with Display and Controls Installation Manual

Sentronic LP IO-Link CLASS A 617 Series. 617 Series IO-Link CLASS A with Display and Controls Installation Manual Sentronic LP IO-Link CLASS A Series Series IO-Link CLASS A with Display and Controls Installation Manual Table of Contents Sentronic LP Description 2 How To Order 2 Operating Elements 3 Manual Pressure

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Type S030. Operating Instructions. Symbols used. INLINE fitting.   Bedienungsanleitung Manuel d'utilisation Type S030 INLINE fitting We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Operating Instructions Bedienungsanleitung

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Flowmeter with paddle-wheel Durchfluss-Messgerät mit Flügelrad Débitmètre à ailette Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without

More information

Series ISA. Air Catch Sensor. For Detection of Work Presence

Series ISA. Air Catch Sensor. For Detection of Work Presence ED Bar graph for easy calibration The ED bar graph indicator in conjunction with the adjustment knob for the variable orifice allows for easy and correct calibrations. Over range (Red) Correct range (Green)

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national

More information

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0 Please read these Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to clutch failure, resulting in damage to other parts. Contents:

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10. 27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE.

S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE. S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE GAMMA/ L THE DOSING PUMPS WITH INTELLIGENCE. M ORE CONTROL VERSATILITY LESS

More information

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA Operating Instructions for Pressure Transmitter with Digital Display Model: PDA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Operating Principle... 3 5. Regulation Use...

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national

More information

OPTISWITCH 6500 C Technical Datasheet

OPTISWITCH 6500 C Technical Datasheet OPTISWITCH 6500 C Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free KROHNE

More information

Infocal 9 Energy calculator for heating and cooling applications

Infocal 9 Energy calculator for heating and cooling applications Installation & User Guide Infocal 9 Energy calculator for heating and cooling applications www.danfoss.com 2 Danfoss Energy Meters 2017.03 VUIGN102 1. Installation 1.1. Preparation Only qualified personnel

More information

Proportional solenoid valve for pneumatic application V PR M

Proportional solenoid valve for pneumatic application V PR M Proportional solenoid valve for pneumatic application 3 Product group V PR M Function / NC Proportional direct-acting Armature space pressure tight up to 16 bar static pressure High linearity Quick response

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

Electronic Pressure Switches

Electronic Pressure Switches 96 Pressure Switches Electronic Pressure Switches Electronic E.5 switching output Electronic pressure switches, High-Performance series with one switching output Outstanding overpressure protection (up

More information

Operating Instructions

Operating Instructions Operating Instructions Safeguard for future use! Options according to range of application Sample application Checking jig DIX PV 100/150 DIX PV 200/250 Aligning module DIX JM 100 DINSE Inc. 830 Dillon

More information

FX2N-2LC SPECIAL FUNCTION BLOCK

FX2N-2LC SPECIAL FUNCTION BLOCK SPECIAL FUNION BLOCK USER S GUIDE JY992D8561E Cautions on Safety (Make sure to read this paragraph before using the unit.) Thoroughly read this manual, a separate USER S MANUAL and all attached documents

More information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information Flat Inductive Standard Flat s in Many Different Variations Only 6 mm thick yet provides a sensing distance of mm (MC1). Aluminum die-cast models also available. Be sure to read Safety Precautions on page

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type LRS 004 Device identification no.: 93.046 690.004 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations.

More information

AXIAL FANS Axis / Tubo OPERATION MANUAL

AXIAL FANS Axis / Tubo OPERATION MANUAL TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements

More information

Pressure Transmitters

Pressure Transmitters Transmitters Wetted parts are all made of stainless steel for high resistance to chemicals Stainless steel diaphragm welded with casing No seals and thus low leakage rate even with difficult gases High

More information

BSW , -204 Inductive Rotary Cam Switches. User's Guide. Rotary Cam Switches BSW BSW

BSW , -204 Inductive Rotary Cam Switches. User's Guide. Rotary Cam Switches BSW BSW BSW 86-0, -04 User's Guide Rotary Cam Switches BSW 86-0 BSW 86-04 Balluff GmbH Schurwaldstrasse 9 7765 Neuhausen a.d.f. Germany Tel. +49 758 7-0 Fax +49 758 500 balluff@balluff.de www.balluff.com Read

More information

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art. Technical Documentation VAPORIX-PCM Corrective control module for connection to VAPORIX-Control Version: 3 Edition: 2016-08 Art. No: 350102 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg, Germany Tel.:

More information

Checking the usage. Slow opening/slow closing damping unit:

Checking the usage. Slow opening/slow closing damping unit: 0 Elster GmbH Edition 0. Translation from the German 0 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Converting a solenoid valve without damping unit into a solenoid valve

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating

More information

Operating Instructions Metering Pump ProMinent CONCEPT b

Operating Instructions Metering Pump ProMinent CONCEPT b l Operating Instructions Metering Pump ProMinent CONCEPT b 60 70 50 80 40 90 30 00 20 ll lll 0 Affix type identification plate here! Please completly read through these operating instructions first! Do

More information

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12 Safety Door Handle System TGY with SIDENT Safety Switch Ref. no. 43.20-01 07, -11, -12 1. Purpose Automated systems with dangerous machine functions require guards to ensure that the operating personnel

More information

HST -LS Interlocking device (Translation of Original Manual)

HST -LS Interlocking device (Translation of Original Manual) Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 Description: The EDS 3000 is a compact, electronic pressure switch with integral digital display. The unit can have one or two switching outputs, and there is the option of an additional analogue output

More information

Please affix device label here!

Please affix device label here! Operating Instructions MTMa (Diaphragm Dosing Pumps) MTKa (Piston Dosing Pumps) MTMa MTKa Please affix device label here! For safe and correct operation of dosing pumps, two sets of Operating Instructions

More information

TOPAS PMW-basic. Customer benefits. Product features

TOPAS PMW-basic. Customer benefits. Product features TOPAS PMW-basic The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement right up to data integration

More information

Explosion protected terminal boxes type, GHG 72.

Explosion protected terminal boxes type, GHG 72. 1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55

More information

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 , IECEx PTB 14.0049X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

PLS / WPLS / PLV / PLS-HP / PLF-HP PLN / WPLN / WGN / PLFN PSN / PSFN PLE / WPLE / PLFE PLPE / WPLPE / PLHE

PLS / WPLS / PLV / PLS-HP / PLF-HP PLN / WPLN / WGN / PLFN PSN / PSFN PLE / WPLE / PLFE PLPE / WPLPE / PLHE Instruction Manual Standard Planetary Gearbox PLS / WPLS / PLV / PLS-HP / PLF-HP PLN / WPLN / WGN / PLFN PSN / PSFN PLE / WPLE / PLFE PLPE / WPLPE / PLHE GB_ 100225283 / Rev. Stand 004 www.zetek.ru +7(495)

More information

Electronic Pressure Switches

Electronic Pressure Switches 96 Pressure Switches Electronic Pressure Switches Electronic E.6 2 switching outputs Electronic pressure switches, High-Performance series with two switching outputs Outstanding overpressure protection

More information

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve Type 3310/AT and Type 3310/3278 Pneumatic Control Valves Type 3310 Segmented Ball Valve Fig. 1 Type 3310/3278 with positioner Fig. 2 Type 3310/AT Mounting and Operating Instructions EB 8222 EN Edition

More information

Pressure Transmitter

Pressure Transmitter Specifications/Instructions Pressure Transmitter General Model PY7100A pressure transmitter is a small pressure transmitter using a semiconductor strain gauge. It detects the pressure of chilled/hot water,

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Flowmeter with paddle-wheel Durchfluss-Messgerät mit Flügelrad Débitmètre à ailette Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without

More information

Magnescale Co., Ltd. High Rigidity High Operability = Tough Sensor. Magnescale Co., Ltd.

Magnescale Co., Ltd. High Rigidity High Operability = Tough Sensor. Magnescale Co., Ltd. Magnescale Co., Ltd. International Sales Department 3-1-4 Edagawa, Koto-ku, Tokyo 135-51, Japan Magnescale Americas Inc. 1 Technology Drive, Suite F7, Irvine, CA 9218, USA Magnescale Europe GmbH Antoniusstrasse

More information

OPTISWITCH 6500 C Technical Datasheet

OPTISWITCH 6500 C Technical Datasheet OPTISWITCH 6500 C Technical Datasheet Microwave Level Switch for advanced hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free

More information

Assembly and operating Instructions Bypass Flow Meter DST

Assembly and operating Instructions Bypass Flow Meter DST Assembly and operating Instructions Bypass Flow Meter 2 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions and exemption from liability... 3 2.3. Intended

More information