50 Hz. e-lnt Series TWIN IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC

Size: px
Start display at page:

Download "50 Hz. e-lnt Series TWIN IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC"

Transcription

1 Hz e-lnt Series TWIN IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS ErP 9/1/EC Cod Rev. A Ed./1

2 Xylect TM Xylect TM is a pump solution software with an extensive online database of product information across the entire range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. Xylect TM can be available: On the website On DVD Loop U On Mobile Apps Loop U Lowara Pump Selector RELEASE 1..3 Cod.191xxxx - Ed.1 For more information, please, see page Ecodesign Directive (ErP) Over last decade the European Commission with the Energy Efficiency Plan pushed the European Parliament and the Council to adopt specific measures to the purpose of reducing energy consumption and further negative environmental impacts. Through the Directives /3/EC, energy-using products (EuP), and 9/1/EC, energy-related products (ErP) a framework for ecodesign requirements was established. The Commission Regulations (EC) No 6/9 and (EU) No /1 have implemented two directives with regard to ecodesign requirements for three-phase Hz electric motors placed on the market and put into service inside EU zone as self-alone units or integrated in other products. This regulation states that motors must have efficiency level IE3 (or IE + Variable Speed Drive) from 1 st January 1 for 7, to 37 kw rated powers and from 1 st January 17 for,7 to 37 kw ones. The Commission Regulation (EU) No 7/1 has implemented two directives with regard to ecodesign requirements for some types of clean water pumps placed on the market and put into service inside EU zone as self-alone units or integrated in other products. This regulation states that water pumps shall have index MEI. as minimum from 1 st January 1. That index comes from a dedicated formula which considers hydraulic efficiency values at best efficiency point (BEP), 7 % of the flow at BEP (Part load PL) and 11 % of the flow at BEP (Over load OL). The Lowara e-lnt series, for the models in the scope of the regulations above, is ErP compliant, having an index MEI equal or higher than, and IE3 motor efficiency. Lowara, HYDROVAR, Xylect are trademarks or registered trademarks of Xylem Inc. or one of its subsidiaries. All other trademarks or registered trademarks are property of their respective owners

3 CONTENTS General Introduction... Applications...6 Identification code...8 Rating plate...9 List of Models at Hz, poles...1 List of Models at Hz, poles...11 Pump cross-section and main components...1 Mechanical seals...1 Motors (ErP 9/1/EC)...1 Pumps (ErP 9/1/EC)...1 Minimum efficiency index (MEI)... Hydraulic performance range at Hz, poles...3 Table of hydraulic performances at Hz, poles... Hydraulic performance range at Hz, poles...9 Table of hydraulic performances at Hz, poles...3 Operating characteristics at Hz, poles...38 Operating characteristics at Hz, poles...6 Dimensions and weights...81 LNT..H (e-lnt with Hydrovar)...97 Accessories Report and declarations...11 Technical appendix

4 e-lnt SERIES HYDRAULIC PERFORMANCE RANGE AT Hz, POLES LN T ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Im p gpm] Q [US gpm ] H [ft] H [m ] Single pump operation Parallel operation Q [m 3 /h] Q [l/s ] A _A_C H HYDRAULIC PERFORMANCE RANGE AT Hz, POLES LN T ~ 1 [rpm] ISO 996:1 - Grade 3B Q [I mp gpm] Q [US gp m] H [m ] H [ft] Single pump operation Parallel operation Q [m 3 /h] Q [l/s] A _A_C H

5 e-lnt SERIES GENERAL INTRODUCTION The new Lowara e-lnt Series is the result of the close collaboration between our customers and us; the new range has been redesigned and improved to meet the Commercial Building Services (CBS) requirements, in terms of performances and energy saving. In addition the new Lowara e-lnt Series can be customized to meet the needs of the Industry, keeping the bestin-class quality in production that affords our pumps continuous reliability and robustness in operation. Pump design The new Lowara e-lnt Series is a dual volute centrifugal pump with in-line suction and delivery flanges; both volutes are fitted with closed impellers linked by an automatic changeover valve. The two pumps can operate separately or in parallel. The e-lnt Series has a Back pull-out design (impeller, adapter, and motor can be extracted without disconnecting the pump body from the piping system). The dual volutes provides system redundancy; and one volute can be serviced while the other remains operational. The pumps have cast iron casing as standard; the impeller standard material is cast iron but is also available in bronze and stainless steel. The pumps are equipped with interchangeable mechanical seals and IE3 efficiency motors; and are available in the following constructions: Extended shaft Close-coupled by means of an adaptor bracket with an impeller keyed directly to the special motor shaft extension. Stub shaft Rigid-coupled with a bracket, an adaptor and a rigid coupling keyed to the standard motor shaft extension. Hydraulic specifications Maximum delivery - (one pump running): 7 m 3 /h (-pole range) 39 m 3 /h (-pole range) - (two pump running): m 3 /h (-pole range) 69 m 3 /h (-pole range) Maximum head: 9 m (-pole range). m (-pole range). Hydraulic performance compliant with ISO 996:1 Grade 3B. Grade B and 1B available upon request. Fluid temperature range: - standard version (with mechanical seal BQ1EGG-WA and EPDM gasket) - to +1 C - versions on request (depending on mechanical seal and gasket) -* or - to +1 or +1 C. Maximum operating pressure: - standard version (with mechanical seal BQ1EGG-WA) 16 9 C and 1 1 C - versions on request (with other mechanical seals) 16 1 C and 1,9 1 C * Fluoro-elastomer: FPM (old ISO), FKM (ASTM & new ISO). List of the Directives - Machinery Directive MD 6//EC Motor specifications Squirrel cage in short circuit enclosed construction with external ventilation (TEFC). -pole and -pole ranges. IP protection degree as motor (EN 63-), IPX as electro-pump (EN 69). Performances according to EN IE3 efficiency level (three-phase,7 to 37 kw). 1 (F) insulation class. Standard voltage: 1 x - V Hz for power up to, kw 3 x -/38-1 V Hz for power up to 3 kw. 3 x 38-1/66-69 V Hz for power above 3 kw. Maximum ambient temperature: C. Note Anti-clockwise rotation when facing pump s suction port. Pump does not include counter-flanges. and the main technical norms EN 89, EN 6-1 (safety) EN 19- (cast iron flanges) - Electromagnetic Compatibility Directive EMCD /18/EC - Ecodesign requirements for energy-related products ErP 9/1/EC Regulation (EC) No 6/9, Regulation (EU) No /1, Regulation (EU) No 7/1 EN , EN EN 63-3:9, IEC :1 (electric motors)

6 e-lnt SERIES COMMERCIAL BUILDING SERVICES (CBS) APPLICATIONS & BENEFITS Applications The Lowara e-lnt Series is suitable for many different applications demanding variable duty points, reliable, and efficient products in cost saving operation. The Lowara e-lnt Series can be used for the following CBS applications: HVAC - Liquid transfer in heating systems. - Liquid transfer in air-conditioning systems. - Liquid transfer in ventilation systems. Water Supply - Pressure boosting in commercial buildings. - Irrigation systems. Benefits The Lowara e-lnt Series permits to achieve the following benefits. Performances: the e-lnt pumps are ErP 1 compliant, equipped with IE3 motors, and with hydraulic target points and coverage that satisfy the needs of CBS applications. The standard full cast iron version with PN16, 1 C maximum fluid temperature, and EPDM elastomer is exactly what the CBS Market needs. Reliability: robust construction and high-quality standards in production, interchangeable mechanical seals and wear rings, guarantee a continuous operation without faults and a shorter down time for maintenance. Dual volute configuration allows for built-in redundancy; but also provides the possibility of parallel operation. Versatility: beside the standard offer, the Lowara e-lnt series is available in different construction as well as with different material configurations for impellers and elastomers; thus addressing a wide range of applications. Total cost ownership: the best-in-class hydraulic and electric efficiency, the Hydrovar-equipped versions, the easy and quick maintenance, allow to reduce the operation and maintenance cost and to save energy when the pump is working or is at rest. Pre-post sales support: we are continuously working close to our customers to help them in selecting the right pump for the specific application. A user-friendly selection software is available on the website, on DVD, or on Apps for mobile phones. Experienced engineers are fully dedicated to big projects. 6

7 7

8 e-lnt SERIES IDENTIFICATION CODE L N T S / 1 8 A / W V C C Motor power [ to 3 digits] kw x 1 Pump Type [3 digits] [LNT] = in-line twin Coupling [1 digit] [E]= extended shaft [S] = stub shaft Motor operation [1 digit] [ ] = standard asynchronous motor [H] = equipped with Hydrovar [X] = other drives Size of the pump [6 to 7 digits] Discharge diameter - nominal impeller diameter e.g. -16, 1-31 Special trimmed Impeller [1 digit] [A or B] = Trimmed medium diameter that doesn t maximize motor power [X] = Trimmed medium diameter to meet customer required duty point Motor type [ digits] [/P] = PLM [/S] = SM [/W] = Weg [/X] = Other N poles [1 digit] [] = poles [] = poles Mech Seal + Oring Config [1 digit] [] = SiC/Carbon/EPDM [] = SiC/Carbon/FKM* [Z] = SiC/SiC/EPDM [W] = SiC/SiC/FKM* [L..] = Tungsten Carbide/ Metal-impreg. carbon/epdm [U..] = Tungsten Carbide/ Metal-impreg. carbon/fkm* Impeller Material [1 digit] [C] = Cast Iron [S] = Fabricated Stainless Steel [B] = Bronze [N] = Cast Stainless Steel (1.8) [R] = Duplex (1.17) EXAMPLES Electrical Voltage + Frequency [digits] Hz H = 1x- V R = 3x-/38-1 V V = 3x38-1/66-69 V P = 3x-8/36-36 V S = 3x-6/-6 V T = 3x9-3/- V W = 3x-6/- V 6 Hz 6F = 1x-3 V 6E = 1x-1 V 6P = 3x-3/38- V 6R = 3x-77/-8 V 6V = 3x-8/- V 6U = 3x38-/66-69 V 6N = 3x-8/36-36 V 6T = 3x33-36/7-6 V Casing Material [1 digit] [C] = Cast Iron * FPM (old ISO), FKM (ASTM & new ISO) LNTS 1-16//WRCC In-line twin, electric pump stub shaft coupling, DN1 nominal discharge port, 16 mm nominal impeller diameter,, kw rated motor power, WEG IE3 model, pole, Hz -/38-1 V, cast iron casing, cast iron impeller, Silicon Carbide/Carbon/EPDM mechanical seal. LNTS 1-//WVCB In-line twin, electric pump stub shaft coupling, DN1 nominal discharge port, mm nominal impeller diameter,,kw rated motor power, WEG IE3 model, pole, Hz 38-1/66-69 V, cast iron casing, bronze impeller, Silicon Carbide/Carbon/EPDM mechanical seal. 8

9 e-lnt SERIES RATING PLATE ELECTRIC PUMP REGULATION (EU) No 7/ LEGEND 1 - Pump / electric pump unit type - Pump code / electric pump unit code 3 - Flow range - Head range - Nominal or maximum pump power 6 - Speed 7 - Serial number or order number 8 - Order position number 9 - Full impeller diameter (only filled in for trimmed impellers) 1 - Trimmed impeller diameter (only filled in for trimmed impellers) 11 - Minimum operating liquid temperature 1 - Maximum operating liquid temperature 13 - Maximum operating pressure 1 - Hydraulic efficiency in best efficiency point 1 - Minimum efficiency index MEI (Regulation (EU) No 7/1) 19 - Weight 9

10 e-lnt SERIES LIST OF MODELS AT Hz, POLES SIZE kw VERSION SIZE kw LNT.. LNTE LNTS LNT.. LNTE LNTS -1/11(*) 1,1 8-16/7 7, -1/1(*) 1, 8-16/9 9, - -1/(*), 8-16/11A / / / /1 1-16/ 8-16/18 18, -16/, 8-/18 18, - -/ 8-/ - -/, 8-/ /7 7, 8-/ /9 9, / /11A /1 1 -/ /18 18, -/ / -1/1(*) 1, 1-/ - -1/(*), 1-/ /3 3 1-/ / 1-/ / -16/, (*) Models available also in single-phase version. -16/7 7, -/7 7, -/9 9, - -/11A / / /1 1 -/18 18, -/ 6-1/ / 6-1/, 6-1/7 7, 6-16/7 7, 6-16/9 9, /11A / / /1 1 6-/18 18, 6-/18 18, 6-/ 6-/3 3 - = Available LNT_models-p-en_a_sc LEGEND LNTE : Extended shaft (twin version). LNTS : Stub shaft (twin version). VERSION 1

11 e-lnt SERIES LIST OF MODELS AT Hz, POLES SIZE kw VERSION SIZE kw LNT.. LNTE LNTS LNT.. LNTE LNTS -1/B, /11A 1,1 - -1/A, /1B 1, - -1/, /11 1,1 - -1/3, /1A 1, - -16/3, /1 1, -16/, 8-16/A, -16/7,7 8-16/, -/, 8-/, - -/7,7 8-/ /11 1,1 8-/ - -/11 1,1-8-/A, - -/1A 1, - 8-/, - -/1 1, 8-/7 7, - -/, 1-16/1 1, -1/A, /A, -1/, /, -1/3, /3 3-1/, 1-/ /, 1-/ - -16/7,7 1-/A, - -16/11 1,1 1-/, - -/11A 1,1 1-/A, - -/11 1,1 1-/, - -/1 1, 1-/7 7, - -/1 1, 1-/ /A, 1-16/, - -/, 1-16/ / / - 6-1/3,37-1-/, - 6-1/, 1-/7 7, - 6-1/7,7 1-/7 7, - 6-1/11 1,1 1-/ /11A 1,1 1-31/ /11 1,1 1-31/18 18, /1 1, 1-31/ - 6-/1 1, 1-31/3 3-6-/A, 1-/, - 6-/, 1-/7 7, - 6-/, 1-/ /3 3 1-/ / 1-/ /18 18, / / / = Available LNT_models-p-en_a_sc VERSION 11

12 LNTE SERIES ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS MATERIAL LNTE REF. PART MATERIAL REFERENCE STANDARDS N. EUROPE USA 1 Volute casing Cast iron EN GJL- (JL1) ASTM Class 3 Casing cover Cast iron EN GJL- (JL1) ASTM Class 3 Impeller (,, 6) Stainless steel EN XCrNiMo17-1- (1. AISI 316L Impeller (8, 1) Cast iron EN GJL- (JL13) ASTM Class 3 3 Impeller (8, 1) Bronze EN CuSn1-C (CC8K) UNS C97 Stub shaft Stainless steel EN XCrNiMo17-1- (1.) AISI 316L Wear ring Stainless steel EN XCrNi18-1 (1.31) AISI 3 6 Impeller lock nut and washer Stainless steel EN XCrNiMo17-1- (1.1) AISI Impeller key Stainless steel EN XCrNiMo17-1- (1.) AISI 316L 9 Fill and drain plugs Nickel-plated brass EN 116-CuZn39Pb3 (CW61N) - 11 O-Ring EPDM (standard version) 1 Mechanical seal Carbon / Silicon carbide / EPDM (standard version) 13 Motor adapter * Aluminium EN 176-AC-AlSi11Cu (Fe) (AC61) - Motor adapter Cast iron EN GJL- (JL1) ASTM Class 3 1 Volute casing fastening bolts and screws Carbon steel 1 Pump base (optional) Carbon steel EN Pump flap complete Stainless steel/epdm A (~ 1.31) / EPDM * / pole: //6-1, /-16 LNTE-en_a_tm 1

13 LNTS SERIES ELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS MATERIAL LNTS REF. PART MATERIAL REFERENCE STANDARDS N. EUROPE USA 1 Volute casing Cast iron EN GJL- (JL1) ASTM Class 3 Casing cover Cast iron EN GJL- (JL1) ASTM Class 3 Impeller (,, 6) Stainless steel EN XCrNiMo17-1- (1.) AISI 316L 3 Impeller Cast iron EN GJL- (JL13) ASTM Class 3 Impeller Bronze EN CuSn1-C (CC8K) UNS C97 Stub shaft Stainless steel EN XCrNiMo17-1- (1.) AISI 316L Stub shaft (8-, 1-, 1-, 1, 1) Stainless steel EN X17CrNi16- (1.7) AISI 31 Wear ring Stainless steel EN XCrNi18-1 (1.31) AISI 3 6 Impeller nut Stainless steel A (~ 1.1) 7 Impeller washer Stainless steel A (~ 1.1) 8 Impeller key Stainless steel EN X6CrNiMo17-1- (1.71) AISI 316Ti 9 Plug Stainless steel EN X6CrNiMo17-1- (1.71) AISI 316Ti 1 Gasket Asbestos-free synthetic fiber AFM 3 11 O-Ring EPDM (standard version) 1 Mechanical seal Carbon / Silicon carbide / EPDM (standard version) 13 Motor adapter * Aluminium EN 176-AC-AlSi11Cu (Fe) (AC61) - Motor adapter Cast iron EN GJL- (JL1) ASTM Class 3 1 Volute - casing fastening screws Carbon steel 1 Pump base Carbon steel EN Pump flap complete Stainless steel/epdm A (~ 1.31) / EPDM * / pole: //6-1, /-16 LNTS-en_a_tm 13

14 e-lnt SERIES MECHANICAL SEALS Mechanical seal with mounting dimensions according to EN 176 and ISO LIST OF MATERIALS 3 1 LNE_M1_A_ot POSITION 1 - POSITION 3 POSITION - B : Resin impregnated carbon E : EPDM G : AISI 316 A : Antimony impregnated carbon V : FKM (FPM) Q 1 : Silicon carbide U 3 : Tungsten carbide TYPE OF SEAL TYPE POSITION 1 3 ROTATING ASSEMBLY FIXED ASSEMBLY ELASTOMERS SPRINGS STANDARD MECHANICAL SEAL OTHER COMPONENTS PRESSURE lne-lnt_ten-mec-en_a_tm TEMPERATURE (bar) ( C ) B Q 1 E G G - WA B Q 1 E G G 16/1 - +9/+1 OTHER TYPES OF MECHANICAL SEAL B Q 1 V G G B Q 1 V G G *) Q 1 Q 1 E G G Q 1 Q 1 E G G Q 1 Q 1 V G G Q 1 Q 1 V G G *) U 3 A E G G U 3 A E G G U 3 A V G G U 3 A V G G *) *) for hot water: max. +9 C lne-lnt_tipi-ten-mec-en_b_tc PRESSURE/TEMPERATURE APPLICATION LIMITS FOR COMPLETE PUMP p [bar] BQ 1 EGG-WA BQ 1 VGG Q 1 Q 1 EGG Q 1 Q 1 VGG 1 U 3 AEGG U 3 AVGG 1 EPDM FKM CB, CC, CN, CR, CS FKM (hot water) EPDM, FKM EPDM, FKM LNE_M_D_ot t [ C] 1

15 ErP 9/1/EC e-lnt SERIES MOTORS With the Energy using Products (EuP /3/EC) and Energy related Products (ErP 9/1/EC) directives, the European Commission has established requirements for promoting the use of products with low power consumption. The various products considered include three-phase Hz surface motors with power outputs ranging from,7 to 37 kw, also when integrated with other products, with characteristics as defined by the specific Regulation (EC) No 6/9 implementing the requirements of the EuP and ErP Directives which also establish the following deadlines: from kw minimum level of efficiency (IE) 16 th June 11,7 37 IE 7 th July 1,7 37 new exclusion criteria 1 ) < 7, IE 1 st January 1 IE3 7, 37 IE fitted with variable speed drive ) IE3 1 st January 17,7 37 IE fitted with variable speed drive ) 1 ) Fixed by subsequent Regulation (EU) No /1. ) IE motor can be supplied without frequency converter as the obligation to have that device is related to when motor works and not when is placed on the market. Short-circuit squirrel-cage motor, enclosed construction with external ventilation (TEFC). Rated power from 1,1 to 37 kw for -pole range and from, to 37 kw for -pole range. IP protection degree. Insulation class 1 (F). Standard three-phase surface motors,7 kw supplied as IE3. IE efficiency level according to EN 63-3:9 and IEC :1 (,7 kw). Electrical performances according to EN Metric cable gland according to EN 6. Single-phase version: - V Hz Built-in automatic reset overload protection up to 1, kw. For higher powers the protection must be provided by the user. Three-phase version: -/38-1 V Hz for power up to 3 kw. 38-1/66-69 V Hz for power above 3 kw. Overload protection to be provided by the user. PTC included as standard only for WEG motors (one per phase, 1 C). Maximum ambient temperature: C. LNTE SERIES SINGLE-PHASE MOTORS AT Hz, POLES INPUT CURRENT CAPACITOR DATA FOR 3 V Hz VOLTAGE P N MOTOR TYPE In (A) Tn kw - V μf V min -1 ls / ln % cos Nm Ts/Tn Tm/Tn IEC SIZE* Construction Design 1,1 SM9RB1S/111 9R B1 6,88-6, ,89 7,7,96 3,7,6 1,7 1, SM9RB1S/11 9R B1 9,1-8,8 81, 76,1,98,1,39 1,7, PLM9B1S/1 9 B1 1,-11,6 7 8,7 8,,97 7,3,3 1,87 * R = Reduced size of motor casing as compared to shaft extension and flange. LNEE-motm-p-en_a_te 1

16 LNTE SERIES THREE-PHASE MOTORS AT Hz, POLES P N V 3 V V 38 V V 1 V Y 38 V Y V Efficiency η N kw / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / 1,1 8, 8,7 83, 8, 8, 8, 8,3 8, 81, 8, 8, 81, 8, 8, 81, 8, 8, 81, 1, 8,6 86, 8,8 8,9 86, 8,9 86, 86, 8, 8,6 86, 8, 8,6 86, 8, 8,6 86, 8,, 86, 87, 86,8 86, 86,9 8,7 86,6 86,7 8, 86, 86,7 8, 86, 86,7 8, 86, 86,7 8, 3 87, 88, 88,3 87, 88, 87, 87, 87,8 86, 87, 87,8 86, 87, 87,8 86, 87, 87,8 86, 89,1 9,1 89, 89,1 9,1 89, 89,1 9,1 89, 89,1 9,3 9, 89,6 9, 89,9 89,6 9,1 89,, 89, 89,6 88, 89, 89,6 88, 89, 89,6 88, 89, 9,3 89,9 89,7 9, 89, 89,6 89,6 88, 7, 9,6 9, 89, 9,6 9, 89, 9,6 9, 89, 9,6 91, 9, 9,8 9,8 89,6 9,7 9, 89, 9, 9,8 91, 89,7 9,8 91, 89,7 9,8 91, 89,7 9,8 91, 9,8 91,1 91,3 9,3 91,1 91, 89, ,3 9, 91,1 91,3 9, 91,1 91,3 9, 91,1 91,3 9, 9, 91,6 9, 91,7 91,7 9, 91,1 1 9, 9, 91, 9, 9, 91, 9, 9, 91, 9,7 93,3 9,9 93,1 93,3 9,7 9, 9, 91, 18, 9,6 93,1 9, 9,6 93,1 9, 9,6 93,1 9, 9,6 93, 93, 9,9 93,3 9,8 9,9 93,1 9, 93, 9,7 91,3 93, 9,7 91,3 93, 9,7 91,3 93, 93, 9, 93,1 93, 91,9 93, 9,7 91,3 % Y 1 V Y 66 V Y 69 V IE 3 Year of manufacture From 11/1 P N kw Manufacturer Xylem Service Italia Srl Reg. No Montecchio Maggiore Vicenza - Italia Model IEC SIZE* Construction Design 1,1 SM9RB1S/311 PE 9R,79 8,31 3,63 3,9 3,9 1, SM9RB1S/31 PE 9R,8 8,8,96,31,1, PLM9B1S/3 E3 9,8 8,77 7,8 3,7 3,7 3 PLM9B1S/33 E3 9,79 7,81 9,93,6 3,9 PLM11RB1S/3 E3 11R,8 9,13 13, 3,8,3, PLM11B1S/3 E3 11,8 1, 18,1,7, , PLM13B1S/37 E3,8 1,, 3,3,76 PLM13B1S3/37 E3 13 PLM13B1S/39 E3 13 9,,8 1,1 3, 3,73,81 PLM13B1S3/39 E3 13 PLM13B1S/311 E ,86 9,89 3,9 3,6,9 PLM13B1S3/311 E PLM16B3S3/31 E3 16,88 9,1 8,6,73,3 18, PLM16B3S3/318 E3 16,88 9,81 9,9,81,3 PLM16B3S3/3 E3 16,8 1,9 71,1 3,6,1 SPECIAL N. of Poles f N Hz Data for V / Hz Voltage T N cosϕ ls / l N Nm Ts/T N Tm/Tn Voltage U N V Y Y P N V 3 V V 38 V V 1 V 38 V V 1 V 66 V 69 V kw I N (A) 1,1,19,1,16,,39,,1,38,38 1,39 1,37 1,,6,9,1 3,1 3,17 3,18 3,1 3,18 3,19 1,8 1,8, 7,97 7,9 7,98,6,6,61,7,,7,6,6 3 11, 11, 11, 6,3 6,33 6, 6,9 6,7 6,3 3,63 3,6 13,6 13, 13, 7,87 7,7 7,7 7,8 7,6 7,61,,, 18,1 17,9 18,1 1, 1, 1, 1,6 1, 1,7 6,1 6, 7,,8,,3 1,3 1,1 1, 1, 1,1 1, 8,3 8,16 9, 3,6 3,1 3, 17,6 17, 17, 17, 17, 17,3 1,1 9, ,7 3, 3,9,6,,,6,, 11,9 11,7 1 7,6 6,1, 7, 6,6 6,1 7, 6,6 6,1 1,9 1,3 18, 8,3 6,7,6 33,7 3,7 3,1 3, 33, 3,7 19,6 19, 7,9 73,1 73,7,1,,6,9,,6 3,6 3,3 min * R = Reduced size of motor casing as compared to shaft extension and flange. LNEE-IE3-mott-p-en_a_te ** Operating conditions to be referred to motor only. About electric pump, refer to limits in user s manual. n N Observe the regulations and codes locally in force regarding sorted waste disposal. Operating conditions ** Altitude Above Sea Level (m) T. amb min/max C 1-1 / ATEX No 16

17 LNTS SERIES THREE-PHASE MOTORS AT Hz, POLES Efficiency η N % V 3 V V 38 V V 1 V Y 38 V Y V Y 1 V Y 66 V Y 69 V P N kw / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / 1,1 8, 8,7 83, 8, 8, 8, 8,3 8, 81, 8, 8, 81, 8, 8, 81, 8, 8, 81, 1, 8,6 86, 8,8 8,9 86, 8,9 86, 86, 8, 8,6 86, 8, 8,6 86, 8, 8,6 86, 8,, 86, 87, 86,8 86, 86,9 8,7 86,6 86,7 8, 86, 86,7 8, 86, 86,7 8, 86, 86,7 8, 3 87, 88, 88,3 87, 88, 87, 87, 87,8 86, 87, 87,8 86, 87, 87,8 86, 87, 87,8 86, 89,1 9,1 89, 89,1 9,1 89, 89,1 9,1 89, 89,1 9,3 9, 89,6 9, 89,9 89,6 9,1 89,, 89, 89,6 88, 89, 89,6 88, 89, 89,6 88, 89, 9,3 89,9 89,7 9, 89, 89,6 89,6 88, 7, 9,6 9, 89, 9,6 9, 89, 9,6 9, 89, 9,6 91, 9, 9,8 9,8 89,6 9,7 9, 89, 11 91,3 9, 91,1 91,3 9, 91,1 91,3 9, 91,1 91,3 9, 9, 91,6 9, 91,7 91,7 9, 91,1 1 9, 9, 91, 9, 9, 91, 9, 9, 91, 9,7 93,3 9,9 93,1 93,3 9,7 9, 9, 91, 18, 9,6 93,1 9, 9,6 93,1 9, 9,6 93,1 9, 9,6 93, 93, 9,9 93,3 9,8 9,9 93,1 9, 93, 9,7 91,3 93, 9,7 91,3 93, 9,7 91,3 93, 93, 9, 93,1 93, 91,9 93, 9,7 91,3 IE 3 Year of manufacture From 11/1 Manufacturer Xylem Service Italia Srl Reg. No P N Montecchio Maggiore Vicenza - Italia kw Model 1,1 SM8B/311 PE 8 1, SM9RB/31 PE 9R, PLM9B/3 E3 9 3 PLM1RB/33 E3 1R PLM11RB/3 E3 11R, PLM13RB/3 E3 13R 7, PLM13B/37 E PLM16RB/311 E3 16R 1 PLM16B/31 E , PLM16B/318 E3 16 PLM18RB/3 E3 18R IEC SIZE* Construction Design B N. of Poles f N Hz cosϕ,79,8,8,79,8,8,8,86,88,88,8 Data for V / Hz Voltage T N ls / l N Nm Ts/T N Tm/Tn 8,31 3,63 3,9 3,9 8,8,96,31,1 8,77 7,8 3,7 3,7 7,81 9,93,6 3,9 9,13 13, 3,8,3 1, 18,1,7,11 1,, 3,3,76 9,89 3,9 3,6,9 9,1 8,6,73,3 9,81 9,9,81,3 1,9 71,1 3,6,1 Voltage U N V Y Y P N V 3 V V 38 V V 1 V 38 V V 1 V 66 V 69 V kw I N (A) 1,1,19,1,16,,39,,1,38,38 1,39 1,37 1,,6,9,1 3,1 3,17 3,18 3,1 3,18 3,19 1,8 1,8, 7,97 7,9 7,98,6,6,61,7,,7,6,6 3 11, 11, 11, 6,3 6,33 6, 6,9 6,7 6,3 3,63 3,6 13,6 13, 13, 7,87 7,7 7,7 7,8 7,6 7,61,,, 18,1 17,9 18,1 1, 1, 1, 1,6 1, 1,7 6,1 6, 7,,8,,3 1,3 1,1 1, 1, 1,1 1, 8,3 8, ,7 3, 3,9,6,,,6,, 11,9 11,7 1 7,6 6,1, 7, 6,6 6,1 7, 6,6 6,1 1,9 1,3 18, 8,3 6,7,6 33,7 3,7 3,1 3, 33, 3,7 19,6 19, 7,9 73,1 73,7,1,,6,9,,6 3,6 3, * R = Reduced size of motor casing as compared to shaft extension and flange. LNES-IE3-mott-p-en_a_te ** Operating conditions to be referred to motor only. About electric pump, refer to limits in user s manual. n N min -1 Observe the regulations and codes locally in force regarding sorted waste disposal. Operating conditions ** Altitude Above Sea Level (m) 1 T. amb min/max C ATEX -1 / No 17

18 LNTE SERIES THREE-PHASE MOTORS AT Hz, POLES P N Efficiency N % V 3 V V 38 V V Y 38 V Y V Y 1 V Y 66 V Y 69 V 1 V kw / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / / 3/ /, , , ,7 8, 81,3 79,8 81,1 81, 79,1 81, 81, 78, 8, 81, 78, 8, 81, 78, 8, 81, 78, 1,1 8,9 8,7 8,7 8,3 8, 83,8 8,3 8, 8,7 8,9 8, 8,7 8,9 8, 8,7 8,9 8, 8,7 1, 86,6 87, 8,7 86,7 86,9 8, 86, 8,9 83,3 86, 8,9 83,3 86, 8,9 83,3 86, 8,9 83,3, 87,6 88,6 88,3 88, 88,8 87,9 88, 88,7 87, 87,6 88,6 87, 87,6 88,6 87, 87,6 88,6 87, 3 88, 89, 88, 88,6 88,9 87,6 88,6 88,6 86,8 88, 88,6 86,8 88, 88,6 86,8 88, 88,6 86,8 3 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89, 88,9 88,6 89, 88, 88,8 89,1 87,9 IE Year of manufacture 6/11 from 11/1 P N kw Manufacturer Xylem Service Italia Srl Reg. No Montecchio Maggiore Vicenza - Italia Model IEC SIZE*, SM71B/3 71,37 SM71B/3 71,,7 SM9RB1S/3 LLM9RB1S/37 9R 9R SM9RBS/3 LLM9RBS/37 9R 9R 1,1 PLM9BS/311 E3 9 1, PLM9BS3/31 E3 9, PLM1BS3/3 E3 1 3 PLM1BS3/33 E3 1 PLM11BS3/3 E3 11 Construction Design B SPECIAL N. of Poles f N Hz cos,9,6,67,67 Data for V / Hz Voltage T N ls / l N Nm Ts/T N Tm/Tn 3,8 1,71 3,16,63 3,39,7 3,,7 3,9 3,77,,38 3,9 3,77,,38,7,78,3,77 3,31,71 6, 7,8,7 3,,68 6,9 9,89 3,9,1,78 7,7 1,,38 3,69,7 7,7 19,7,8,1,79 8,3 6,3 3,19, Voltage U N V Y Y P N V 3 V V 38 V V 1 V 38 V V 1 V 66 V 69 V kw I N (A), 1,68 1,71 1,77,97,99 1, ,37,6,3,6 1, 1,6 1, ,,98 3,3 3,1 1,7 1,7 1, ,7 3,8 3,3 3,1 1,78 1,7 1,7 1,78 1,7 1,7 1,3 1,1 1,1,61,9,6,66,6,67,6,63,6 1,3 1, 1, 6,3 6,1 6,1 3,66 3,7 3,7 3,6 3,68 3,69,11,13, 8,19 8, 7,97,73,6,6,7,6,6,71, , 11, 11, 6,66 6,6 6,67 6,63 6,9 6,63 3,83 3,81 1,8 1,6 1, 8, 8, 8,36 8, 8,3 8,19,8,7 n N min Observe the regulations and codes locally in force regarding sorted waste disposal. Operating conditions ** Altitude T. amb ATEX Above Sea min/max Level (m) C 1-1 / No * R = Reduced size of motor casing as compared to shaft extension and flange. LNEE-IE3-mott-p-en_a_te ** Operating conditions to be referred to motor only. About electric pump, refer to limits in user s manual. 18

19 LNTS SERIES THREE-PHASE MOTORS AT Hz, POLES P N Efficiency η N V 3 V V 38 V V Y 38 V Y V Y 1 V Y 66 V Y 69 V 1 V kw / 3/ / / 3/ / / 3/ / / 3/ / / 3/ / / 3/ /, ,7 8, 81,3 79,8 81,1 81, 79,1 81, 81, 78, 8, 81, 78, 8, 81, 78, 8, 81, 78, 1,1 8,9 8,7 8,7 8,3 8, 83,8 8,3 8 8,7 8,9 8 8,7 8,9 8 8,7 8,9 8 8,7 1, 86,6 87 8,7 86,7 86,9 8, 86, 8,9 83,3 86, 8,9 83,3 86, 8,9 83,3 86, 8,9 83,3, 87,6 88,6 88,3 88, 88,8 87,9 88, 88,7 87, 87,6 88,6 87, 87,6 88,6 87, 87,6 88,6 87, 3 88, 89, 88, 88,6 88,9 87,6 88,6 88,6 86,8 88, 88,6 86,8 88, 88,6 86,8 88, 88,6 86,8 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89,1 87,9 88,6 89, 88,9 88,6 89, 88, 88,8 89,1 87,9 3, 9, 9,9 89,7 9, 9,9 89,7 9, 9,9 89,7 9, 91, 9, 9,9 91,1 9, 9,9 9,9 89,7 7, 9, 91, 9, 9, 91, 9, 9, 91, 9, 9, 91, 91,1 9,7 91,3 9,8 9,9 91, 9, 11 91, 9, 91, 91, 9, 91, 91, 9, 91, 91, 9, 9, 91,9 9, 9 91,9 9, 91, 1 9, 9, 9,8 9, 9, 9,8 9, 9, 9,8 9, 93, 9,7 9, 9,7 91,8 9, 9, 9,8 % IE Year of manufacture 11 from 11/1 P N kw Manufacturer Xylem Service Italia Srl Reg. No Montecchio Maggiore Vicenza - Italia Model IEC SIZE Construction Design N. of Poles, SM8B/3 8,67 3,9 3,77,,38,7 LLM8B/37 8,7,78,3,77 3,31 1,1 PLM9B/311 E3 9,71 6, 7,8,7 3, 1, PLM9B/31 E3 9,68 6,9 9,89 3,9,1, PLM1B/3 E3 1,78 7,7 1,,38 3,69 3 PLM1B/33 E3 1 B,7 7,7 19,7,8,1 PLM11B/3 E3 11,79 8,3 6,3 3,19,, PLM13B/3 E3 13,76 7,6 3,9,8 3,6 7, PLM13B/37 E3 13,79 7,7 9,1,69 3,7 11 PLM16B/311 E3 16,81 7,19 71,, 3,6 1 PLM16B/31 E3 16,77 8,3 97,,97 3,99 f N Hz cosϕ Data for V / Hz Voltage ls / l N T N Nm Ts/T N Tm/Tn Voltage U N Operating conditions ** V Y Y Altitude T. amb ATEX P N V 3 V V 38 V V 1 V 38 V V 1 V 66 V 69 V n N Above Sea min/max I N (A) min -1 Level (m) C kw,,98 3,3 3,1 1,7 1,7 1, ,7 3,8 3,3 3,1 1,78 1,7 1,7 1,78 1,7 1,7 1,3 1,1 1,1,61,9,6,66,6,67,6,63,6 1,3 1, 1, 6,3 6,1 6,1 3,66 3,7 3,7 3,6 3,68 3,69,11,13, 8,19 8, 7,97,73,6,6,7,6,6,71, , 11, 11, 6,66 6,6 6,67 6,63 6,9 6,63 3,83 3,81 1,8 1,6 1, 8, 8, 8,36 8, 8,3 8,19,8,7,, 19,7 19, 11,6 11, 11, 11,7 11, 11, 6,7 6,6 7, 6,6 6,1,8 1, 1,1 1,9 1, 1, 1,1 8,9 8, ,3 37,3 37,,1 1,8 1,7 1,9 1, 1,3 1,6 1,3 1 1,8,,7 9,9 3, 3, 3, 3,7 31, 17,6 17, / + No ** Operating conditions to be referred to motor only. About electric pump, refer to limits in user s manual. LNES-IE3-mott1-p-en_a_te Observe the regulations and codes locally in force regarding sorted waste disposal. 19

20 LNTS SERIES THREE-PHASE MOTORS AT Hz, POLES (from 18, to 37 kw) Efficiency η N P N kw 18, 3 37 % 38 V V 1 V Y 66 V Y 69 V / 3/ / / 3/ / / 3/ / 93,1 9,9 9, 93,3 9,9 9, 93, 9,8 91,8 93, 93,1 9,8 93,6 93, 9, 93,6 9,8 91,9 9,1 9,1 93, 9, 9, 93, 9, 93,9 9, 9,3 9, 9,1 9,6 9,6 9, 9,7 9,6 93,8 IE 3 Year of manufacture from 11/1 Manufacturer WEG Equipamentos Eletricos S.A. Data for V / Hz Voltage Reg. No /1- P N Jaragua do Sul - SC (Brazil) N. of f N T N kw Model Poles Hz cosϕ ls / l N Nm Ts/T N Tm/Tn 18, W 18M-B 18.kW E3 18,8 7,3 1,,7 3, W 18L-B kw E3 18,83 7,3 1,9,8 3,3 B 3 W L-B 3kW E3,8 7,3 193,6, 3, 37 W S-B 37kW E3,86 7,8 38,7,7 3, IEC SIZE Construction Design P N kw 18, 3 37 Voltage U N V Operating conditions ** Y Altitude T. amb ATEX 38 V V 1 V 66 V 69 V n N Above Sea min/max I N (A) min -1 Level (m) C 3,9 3,9 3,,7, 17,1,9,, 3,7 17 7,7 6,1, 33, 3, / + No 68, 6,6 63,9 39, 38, 18 ** Operating conditions to be referred to motor only. About electric pump, refer to limits in user s manual. LNES-IE3-mott37-p-en_a_te Note: Observe the regulations and codes locally in force regarding sorted waste disposal. See note. MOTOR NOISE The tables below show the mean sound pressure levels (Lp) measured at 1 meter s distance in a free field according to the A curve (ISO 168 standard). The noise values are measured with idling Hz motor with a tolerance of 3 db (A). LNTE, LNTS MOTORS POLES Hz POWER MOTOR TYPE NOISE POWER MOTOR TYPE LpA kw IEC SIZE * db kw IEC SIZE * 1,1 8-9R <7, 71 <7 1, 9R <7,37 71 <7, 9 <7, 9R < R <7,7 9R <7 11R <7 1,1 9 <7, 11-13R <7 1, 9 <7 7, 13 71, 1 <7 9, < R < , 13 <7 18, , 13 < < <7 18, 18 <7 18 <7 3 <7 37 <7 *R=Reduced size of motor casing as compared to shaft extension and flange. LNTE, LNTS MOTORS POLES Hz NOISE LpA db LNE_mott-en_a_tr

21 ErP 9/1/EC e-lnt SERIES PUMPS Over last decade the European Commission with the Energy Efficiency Plan pushed the European Parliament and the Council to adopt specific measures to the purpose of reducing energy consumption and further negative environmental impacts. Through the Directives /3/EC, energy-using products (EuP), and 9/1/EC, energy-related products (ErP) a framework for ecodesign requirements was established. The Commission Regulation (EU) No 7/1 has implemented two directives with regard to ecodesign requirements for some types of clean water pumps placed on the market and put into service inside EU zone as self-alone units or integrated in other products. For end-suction close-coupled in-line pumps (ESCCi for the Regulation) the efficiency assessment refers to: just the pump and not the pump and motor assembly (electric or combustion); pumps with just one impeller; pumps with a nominal pressure PN not higher than 16 bar (16 kpa); pumps with a minimum nominal flow not less than 6 m 3 /h; pumps with a maximum nominal power at the shaft not higher than 1 kw; pumps designed to operate at a speed of 9 min- 1 (for electric pumps this means Hz -pole electric motors) and with a head not greater than 1 metres; pumps designed to operate at a speed of 1 min- 1 (for electric pumps this means Hz -pole electric motors) and with a head not greater than 9 metres; use with clean water at a temperature ranging from -1 C to 1 C (the test is performed with cold water at a temperature not higher than C). According to the definitions established in the Regulation LNTE and LNTS versions correspond to the end-suction close-coupled in-line pump. This regulation states that water pumps shall have a minimum index MEI coming from a dedicated formula which considers hydraulic efficiency values at best efficiency point (BEP), 7 % of the flow at BEP (Part load PL) and 11 % of the flow at BEP (Over load OL). The Regulation also establishes the following deadlines. from minimum efficiency index (MEI) 1 st January 13 MEI,1 1 st January 1 MEI, Regulation (EU) n. 7/1 Annex II point (Product information requirements) 1) Minimum efficiency index: see MEI values in specific tables on following page. ) The benchmark for most efficient water pumps is MEI,7. 3) Year of manufacture: 1. ) Manufacturer: Xylem Service Italia Srl - Reg. No Montecchio Maggiore, Vicenza, Italy. ) Product type: see the PUMP TYPE column in the tables in the Hydraulic performance section. 6) Hydraulic pump efficiency with trimmed impeller: see ηp and ØT columns in the tables in the Hydraulic performance section. 7) Pump performance curves, including the performance curve: see the Operating Characteristics graphs in the following pages. 8) The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter. 9) The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system. 1) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. 11) Designed for use below 1 C only : note not applicable to these products. 1) Designed for use above 1 C only : note not applicable to these products. 13) Specific instructions for pumps as per points 11 and 1: not applicable to these products. 1) Information on benchmark efficiency is available at : (Ecodesign section). 1) The benchmark efficiency graphs with MEI =.7 and MEI =. are available at or (refer to ESCCi 1 rpm ). 1

22 e-lnt SERIES MINIMUM EFFICIENCY INDEX (MEI) -POLE -POLE PUMP SIZE LNTE LNTS PUMP SIZE LNTE LNTS -1/1,, -1/1,, -16/171,, -16/171,, -/,, -/,, -/9,, -/9,, -1/13,, -1/13,, -16/16,, -16/16,, -/199,, -/199,, -/7,,, -/7,,, 6-1/18,, 6-1/18,, 6-16/176,, 6-16/176,, 6-/9,, 6-/9,, 6-/6,, 6-/6,, 8-16/18,, 8-16/18,, 8-/,, 8-/,, 8-/9,, 8-/8,, 1-16/177,, 1-16/177,, 1-/8,, 1-/19,, 1-/1,, 1-/9,, 1-16/18 ---, 1-/7 ---, 1-/9 ---, 1-31/33 ---, 1-/ ---, 1-/9 ---, 1-31/3 ---, LNT-MEI-en_a_sc

23 e-lnt SERIES (SINGLE OPERATION) HYDRAULIC PERFORMANCE RANGE AT Hz, POLES LNT (S) ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] H [m] H [ft] Q [m 3 /h] Q [l/s] A_A_CH 3

24 e-lnt,, 6 SERIES (SINGLE OPERATION) HYDRAULIC PERFORMANCE TABLE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T ηp % l/s 1,8,7 3,6,, 6,3 7, 8,1 9, 9,9 1,8 11,7 P N m 3 /h kw mm (1) () (3) -1/11* 1,1 113,7 1,6 1,7 1, 13,1 11, 8,8-1/1* 1, 13 6, 17,9 17,7 16,9 1, 13, 1,6-1/*, 133 8,3 3, 3,1, 1,3 19,6 17, 1,7 11,6-1/ ,9 7,7 7,3 6,, 3,1,8 17,9 1,7-16/ , 3, 31, 3,9 3,3 9,1 7,3,9 1,9-16/ ,7 3, 3,6 3,6 3,3 3, 3,9 3,8 8,,1 1,6-16/, ,,,7, 39,8 38,6 36,9 3,6 31,9 8,6, 1, -/ 171, 38,1 37,1 36, 3,3 33,6 31,1 -/, 186 1,8,6,6 3,9,9 1, 39,6 36,8 -/7 7, 3,7 6,1, 3,,3,8 8,7 6,, -/9 9, 6 7,3 66,9 66,9 6,3 63, 6,7 7,8 -/11A ,3 66,9 66,9 6,3 63, 6,7 7,8 -/ ,1 7, 7,3 7,3 69,9 67, 63,9 -/ ,7 89,8 89,3 87, 8,1 8, 79, 76, 7, 67,9 PUMP Q = DELIVERY TYPE Ø F T ηp % l/s,7,,6 7, 8, 9,9 11,3 1,7 1, 1,6 17, 18, P N m 3 /h kw mm (1) () (3) -1/1* 1, 1 9, 1,3 13,8 13,3 1,3 1,8 8,9-1/*, , 18,1 17,1 16,3 1,1 13, 11, 9,1-1/ ,7 1,9 1,,3 19,3 17,9 16, 13,9 11, -1/ 13 6,,8, 3,3,1, 18, 16, 13,7 11,1-16/ , 7,3 7, 6,7,9,7 3,,9-16/, 1 6,1 33,8 33, 33,3 3,8 31,9 3, 8,8 6,6-16/7 7, 16 66, 39,1 38,6 38, 37, 36,3 3,8 3,9 3,6 -/7 7, 179 7,,8,8 1,6,3 38,8 37,1 3, 3,1 -/9 9, 189 8, 8, 8,3 7,,7,3,6, 37,3 3,3 -/11A , 8, 8,3 7,,7,3,6, 37,3 3,3 -/ , 3,6,9 1,, 8, 6,6,1,3 3,6 -/ , 61,3 6,3 61,3 9,6 7,,1, 9, -/ ,9 7,9 73, 71,9 69,9 67,6 6,1 6, 9,3 -/18 18, 3 6, 83, 8, 83, 81,1 78,9 76, 73,8 7,9 67,6 63, -/ 7, 61, 9, 9,3 9,1 9,3 9,1 87,7 8, 8,3 79,3 7,8 71,6 PUMP Q = DELIVERY TYPE Ø F T ηp % l/s,17 7 9,9 11,7 1 16, 18,9,7,98,3 7,76 9,7 P N m 3 /h kw mm (1) () (3) H = TOTAL HEAD METRES COLUMN OF WATER H = TOTAL HEAD METRES COLUMN OF WATER H = TOTAL HEAD METRES COLUMN OF WATER 6-1/ ,9 18,7 17,8 17, 16,3 1,9 13, 1,8 6-1/ 13 67,,,7 19,9 18,7 17,1 1,1 1,7 6-1/, 1 68,7 7,3,8,,,7,9 18,8 16, 13,7 6-1/7 7, 18 7,1 31,1 9,6 8,9 8, 6,7, 3, 1, 18, 1,6 6-16/7 7, 19 6,9 3,6 31,1 3,3 9,3 7,8 6, 3,7 1, 18, 6-16/9 9, 17 67, 37,1 3,6 3,9 33,9 3,6 3,9 8,9 6, 3,6, 6-16/11A , 37,1 3,6 3,9 33,9 3,6 3,9 8,9 6, 3,6, 6-16/ ,,, 39,8 38,9 37,7 36,1 3,3 3, 9, 6, 3, 19,8 6-/ ,8,1,1,1,,3 37,8 3, 6-/ ,,1,3,6 3,3 1, 9, 6, 3,,3 6-/18 18, 9 67,7 6, 6, 61,1 9,3 7,1, 1,7 8,7, 6-/18 18, 6,3 66,6 67, 66, 6,9 6,6 9,7 6,1 6-/ 3 66,3 7, 7, 7,7 73,3 71, 68, 6, 61,3 6,8 6-/ , 91,6 9, 91,3 89,6 87,3 8, 81,1 77, 7,7 Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT---6_pS_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller (3) Hydraulic efficiency of pump *Available also in single-phase version.

25 e-lnt 8, 1 SERIES (SINGLE OPERATION) HYDRAULIC PERFORMANCE TABLE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T ηp % l/s 7 11,6 16,7,9,91 9,3 33,7 38,16,8 7 1,1 6 P N m 3 /h kw mm (1) () (3) 8-16/7 7, 1 71, 8,3 7,9 7, 6,, 1,3 8-16/9 9, 11 71, 3,8 9,9 8,8 7,,3,9 8-16/11A ,9 3,8 9,9 8,8 7,,3,9 8-16/ ,7 3, 33, 3, 3,8 8,, 1, 17,3 8-16/ , 1,8 1,, 38,9 36,9 3, 3,8 6,9,6 8-16/18 18, 18 7,9, 3,,8 1,6 39,7 37,1 33,9 3,,8 8-/18 18, 189 7, 9, 9, 8, 6, 3,6 39,9 3, 3,1 8-/ 199 7,8,1,,, 9,9 6,,3 37,3 8-/3 3 7,6 68, 68,3 67, 66,1 6, 61,1 7, 3, 8, 8-/ ,3 7, 7,8 7, 73, 71, 69, 6,8 61,9 7,, 7, 1, PUMP TYPE Ø F T ηp % l/s 1 16,, 8, 3,6,8 6,3,31 8,33 6,3 7,37 76 P N m 3 /h kw mm (1) () (3) 1-16/ ,9 6,7,9,,1,6, 17,8 1-16/ , 3, 3,9 9,9 8,6 6,8, 1,6 1-16/18 18, , 36,9 3,3 3, 33,1 31, 9, 6,8 3,6 1-16/ 177 7, 1, 39,6 38,7 37, 3,9 3, 31,6 8,7, 1-/ ,7 1,, 39,7 38,7 37, 3, 3,8 6,, 1-/ ,8 8,3 7, 6,6,8,,3 39, 3,6 3,7,9 1-/ ,, 3,9 3,,8 1,7, 7,,3,1 3,1 9,, 1-/ ,9 63, 6, 9,7 9, 8, 6,7,1 3,, 7, Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT-8-1_pS-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller (3) Hydraulic efficiency of pump. H = TOTAL HEAD METRES COLUMN OF WATER Q = DELIVERY H = TOTAL HEAD METRES COLUMN OF WATER

26 e-lnt SERIES (PARALLEL OPERATION) HYDRAULIC PERFORMANCE RANGE AT Hz, POLES LNT (P) ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] H [ft] H [m] Q [m 3 /h] Q [l/s] A1_A_CH 6

27 e-lnt,, 6 SERIES (PARALLEL OPERATION) HYDRAULIC PERFORMANCE TABLE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T l/s 3,,9 6,6 8,3 1, 11,7 13, 1,1 16,8 18,,, P N m 3 /h kw mm (1) () -1/11* 1, ,6 1, 13, 11,8 9, -1/1* 1, 13 17,9 18, 17,3 1,9 13,9 11, -1/*, 133 3, 3,3,8 1,8,3 18, 1,7 1,8-1/ ,7 7,7 6,9,7 3,9 1,7 19, 16, -16/ , 3,7 3, 9,1 7,,,3-16/ 161 3,1 3, 3,1 3, 3,8 3,8 8,,1 1, -16/, 171,1,3 39, 38,3 36,6 3,3 31,6 8,3, -/ , 37, 37, 36,1 3,8 3,9 3,1 -/, 186,7, 3,6,,9 38,6 3,6 31,7 -/7 7, 6,3,, 3,1 1,7 9,9 7,6,,7 3,8 -/9 9, 6 67,7 6, 63, 6, 7,1 3,1 -/11A ,7 6, 63, 6, 7,1 3,1 -/ , 7, 7, 69,8 66,7 63, 8,7 -/ , 87, 8, 8,3 79, 7, 7,7 6,7 6, PUMP TYPE Ø F T l/s, 8,3 11, 1,1 16,9 19,8,6, 8, 31, 3,1 36,9 P N m 3 /h kw mm (1) () -1/1* 1, 1 1,8 13, 1, 1,8 8, -1/*, ,6 16, 1, 13, 1, -1/3 3 13,6, 19, 17, 1, 1, -1/ 13 6,6,3 3, 1,6 19, 16,8 13, -16/ 139 7,9 6,,6,1 1,9 18,9 1, -16/, 1 3,7 33,1 3, 31,3 9, 7, 3,9,1-16/7 7, 16, 38, 37,8 36,8 3,3 33, 3, 7,1 3,1 -/7 7, 179 3, 3, 1, 39, 37, 33,8 9, 3,7 -/9 9, 189 8,8 8,6 7,1,,8 39,9 36, 31,3,8 -/11A ,8 8,6 7,1,,8 39,9 36, 31,3,8 -/ ,, 3, 1, 8,9 6,,9 38,7 33, 6, -/ ,8 6,1 6,9 9, 6,, 8,, -/ ,8 73,1 71, 69, 6,9 61,9 7,1 1, -/18 18, 3 8,7 8,1 8,6 8, 77,6 7, 69,7 6,6 8,7 1,9 -/ 7, 96,6 9,1 93,6 91,7 89,1 8,8 81,9 77,3 71,9 6,7 8,7 PUMP TYPE Ø F T l/s 1,3 1 18,,6 6,8 3,9 3,1 38,1,13 6,1,1,167 P N m 3 /h kw mm (1) () H = TOTAL HEAD METRES COLUMN OF WATER Q = DELIVERY H = TOTAL HEAD METRES COLUMN OF WATER Q = DELIVERY H = TOTAL HEAD METRES COLUMN OF WATER 6-1/ ,3 17, 16, 1,3 13,7 11, 8,9 6-1/ 13,9,1 19, 17, 1,7 13,3 1, 6-1/, 1 8,1,,,9 1,3 19,3 16,9 1, 1,8 6-1/7 7, 18 3,1 8, 6,8, 3, 1, 18,8 1,8 1, 6-16/7 7, 19 3,1 3,6 9, 8,1 6,3,1 1, 18, 1,9 6-16/9 9, 17 38,8 3, 3,1 3,8 31, 9, 6,8 3,9,7 17, 6-16/11A ,8 3, 3,1 3,8 31, 9, 6,8 3,9,7 17, 6-16/ ,9 39,1 37,8 36,3 3, 3, 9,6 6,6 3, 19, 1, 6-/ ,8,,9 1, 38,6 3,8 3, 8,6 6-/ ,8, 3, 1,8 9,7 7,1,1,7 36,9 3,6 6-/18 18, 9 6,1 61, 9,6 7,6,, 9,,6 1,6 37, 6-/18 18, 67,1 66, 6, 63,6 61,1 7,9 3,9 9,3 6-/ 3 7, 7, 73, 7, 69,7 66,8 63,1 8,8, 6-/ ,3 91, 9, 88,1 8,7 8,6 78,9 7,6 69,7 6, Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT---6_pP-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller *Available also in single-phase version. 7

28 e-lnt 8, 1 SERIES (PARALLEL OPERATION) HYDRAULIC PERFORMANCE TABLE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T l/s 1 1,86 9, 36,6, 1, 8,8 66, 73,6 81, 88,36 96 P N m 3 /h kw mm (1) () 8-16/7 7, 1 8,7 7,3 6,8, 3,, 8-16/9 9, 11 31,3 9,3 8, 6, 3,, 8-16/11A ,3 9,3 8, 6, 3,, 8-16/ ,9 3,8 31,8 3,1 7,,, 8-16/1 1 17,7, 39,6 38, 36,1 33,3 9,8 6,, 8-16/18 18, 18,3,9,1,8 38,9 36, 3,9 9,1,1 8-/18 18, 189 9, 9, 7,7,, 38, 3,1 9, 8-/ 199,1,7 3,6 1,6 8,8,,9 36,3 8-/3 3 68,1 67,8 66,9 6,3 63, 9,9 6,1 1,7 6,9 8-/ ,3 73, 7,1 7,3 67,7 6,3 6,,6,6,7 1, PUMP TYPE Ø F T l/s 3 31,86 1,18,9 9,8 69,1 78,3 87,7 97,6 16, 11,69 1 P N m 3 /h kw mm (1) () 1-16/ ,8 3,3,,8 17,6 1-16/ ,7 8,7 7,8 6,7,7 1,1 1-16/18 18, ,3 33, 3, 31, 9, 6,9, 1-16/ 177 1,8 37, 36,1 3, 33,8 31,8 8, 1-/ 181 1, 39,8 39,6 39,1 38, 36, 3, 31,1 6,6 19,7 1-/ ,9 6, 6,, 3,8, 39,6 36,3 31,7, 1-/ , 3,3,9, 1,1 9, 7,,8 1,3 36,6 3,, 1-/ , 9, 8, 7,6 6,3,8,8,3 7, Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT-8-1_pP-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller. H = TOTAL HEAD METRES COLUMN OF WATER Q = DELIVERY H = TOTAL HEAD METRES COLUMN OF WATER 8

29 e-lnt SERIES (SINGLE OPERATION) HYDRAULIC PERFORMANCE RANGE AT Hz, POLES LNT (S) ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] H [m] H [ft] Q [m 3 /h] Q [l/s] A_A_CH 9

30 e-lnt,, 6 SERIES (SINGLE OPERATION) HYDRAULIC PERFORMANCE RANGE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T ηp % l/s,7 1, 1,7,,7 3, 3,6,1,6,1,6 6,1 P N m 3 /h kw mm (1) () (3) -1/B, 113, 3,8 3,9 3,8 3, 3,1, -1/A, 13,,,6,, 3,,7-1/, 133 6,9,,,3,9, 3,8 3, -1/3,37 1 8,6 6, 6,6 6, 6,1,7,, 3,6-16/3,37 1 9,3 7,3 7,6 7, 7, 6,9 6,,7-16/, 161 6, 8, 8,7 8, 8,1 7,7 7,1 6,,6-16/7, ,8 9,7 9,9 9,8 9, 9,1 8,6 7,9 7, 6,3, -/, 171 7,1 9, 9,1 8,9 8, 7,9 7,1 -/7, ,6 11, 1,8 1, 1, 9,3 8,3 -/11 1,1, 13,8 13, 13,1 1,7 1,1 11,3 1, -/11 1,1 6 8,6 16,6 16, 16, 1,3 1, 13, 1,3 1,9 -/1A 1, 6 8,6 16,6 16, 16, 1,3 1, 13, 1,3 1,9 -/1 1, 39 9, 18,8 18,6 18, 17,6 16,9 16, 1,9 13,6 -/, 9 1,1,3,3 1,9 1,,8, 19, 17,9 16,6 1,1 PUMP Q = DELIVERY TYPE Ø F T ηp % l/s 1,3,,7 3,,1,8, 6,1 6,8 7, 8, 8,9 P N m 3 /h kw mm (1) () (3) -1/A, 1 9,3 3, 3, 3,1 3,,7,3-1/, ,,3, 3,9 3,6 3,3,9-1/3, ,9,,9,8,6,3, 3, 3, -1/, 13 6, 6,,8,7,,1,7,3 3,7-16/, , 6,8 6,7 6,6 6, 6,1,7, -16/7,7 1 6, 8, 8,3 8, 8,1 7,8 7, 7,1 6,6 6,,3-16/11 1,1 16 6, 9,7 9,6 9, 9, 8,9 8,6 8,1 7,6 7, 6,3 -/11A 1,1 179,7 1,6 1, 9, 9, 8,3 7,6 6,7 -/11 1,1 189,7 11,9 11, 1,9 1, 9,8 9,1 8,3 7,3 -/1 1, 199 6,7 13,3 1,8 1, 11,9 11,3 1,6 9,9 9, 8, -/1 1, 1,7 1,3 1, 1,7 1, 13,6 1,9 1,1 11,3 -/A, 8 7, 18,3 17,7 17,3 16,7 16,1 1,3 1, 13,7 -/, 3 7,9,9,, 19, 18,9 18, 17, 16,6 -/3 3 7, 9, 3, 3,1,8,3 1,7 1,,3 19, 18,6 17,7 PUMP Q = DELIVERY TYPE Ø F T ηp % l/s,38,919 6, 7,3 8,83 1,1 11, 1,7 1,6 1,361 16,667 P N m 3 /h kw mm (1) () (3) H = TOTAL HEAD METRES COLUMN OF WATER H = TOTAL HEAD METRES COLUMN OF WATER H = TOTAL HEAD METRES COLUMN OF WATER 6-1/3, ,7,6,, 3,9 3,,9 6-1/, 13 66,,,1,8, 3,9 3,3,6 6-1/7,7 1 67,6 6,8 6,3 6,1,7,3,8,1 3,, 6-1/11 1, ,9 7,7 7, 7, 6,7 6,3,8,, 3,7,8 6-16/11A 1, , 8,1 7,7 7, 7,1 6,6 6,,3, 3, 6-16/11 1, ,1 9, 8,8 8, 8, 7,8 7,3 6,6,8,9 3,9 6-16/1 1, , 1, 1, 9,7 9, 9,1 8,6 8, 7,3 6,,, 6-/1 1, 179 6, 1,9 11, 1,6 1,1 9, 8,7 7,8 6-/A, ,8 13,3 13, 13, 1,7 1,1 11, 1,7 9,7 6-/, 9 67,9 1,1 1, 1, 1,6 1, 13, 1,7 11,8 1,8 6-/, 6, 16,6 16,3 16, 1, 1,7 13,8 1,8 11, 1,1 6-/ , 18,6 18,3 18, 17, 16,8 16, 1, 13,8 1, 1,9 6-/ 6 68,,8,3 1,9 1,3, 19,6 18,6 17, 16,1 1,6 1,9 Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT---6_pS-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller (3) Hydraulic efficiency of pump. 3

31 e-lnt 8, 1 SERIES (SINGLE OPERATION) HYDRAULIC PERFORMANCE RANGE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T ηp % l/s 6,91 8,6 11, 13,1 1,99 18,6,9 3,1,88 8,39 31 P N m 3 /h kw mm (1) () (3) H = TOTAL HEAD METRES COLUMN OF WATER 8-16/11A 1,1 1 7,3 6,8 6,9 6,7 6,3,6,8 3,7 8-16/1B 1, 1 7,3 6,8 6,9 6,7 6,3,6,8 3,7 8-16/11 1, , 7, 7, 6,9 6,3,, 8-16/1A 1, 11 71, 7, 7, 6,9 6,3,, 8-16/1 1, 19 71,8 8,3 8, 7,9 7,3 6,,6, 8-16/A, 17 73,3 1,1 1, 9,8 9,3 8,6 7,8 6,8,6 8-16/, 18 7,1 1,7 1,8 1, 1, 9,3 8, 7,6 6,, 8-/, ,3 1,3 1,1 11,7 11,1 1,1 8,9 7,3 8-/ , 13,7 13, 13,1 1,6 11,7 1,6 9,1 7, 8-/ 7,1 16,9 16,7 16, 16, 1, 1,3 13,1 11,6 9,9 8-/A, 9 7, 17,7 18,7 18, 17,9 17,1 16, 1,1 13,9 1, 1,9 8-/, 3 71,,1 1,,9, 19,8 18,9 17,9 16,8 1, 1, 1, 8-/7 7, 8 7,,8, 3,8 3,,8, 1, 19,9 18,7 17,3 1,8 1, PUMP Q = DELIVERY TYPE Ø F T ηp % l/s 6 9, 1,33 1,3 18, 1,6,7 7,86 3,96 3,7 37,17 P N m 3 /h kw mm (1) () (3) H = TOTAL HEAD METRES COLUMN OF WATER 1-16/1 1, 1 7,7 6,7,9,8,6,3,7, 3, 1-16/A, 18 7, 8, 7, 6,9 6,7 6,3,7,9 3,9 1-16/, 168 7,8 9,3 8, 7,9 7,7 7, 6,9 6,,3,3 1-16/ , 1,3 9, 8,9 8,7 8, 8, 7, 6,6,6, 1-/ ,7 1,8 1,7 1,6 1,3 9,8 9, 7,9 1-/ 19 7,9 1,6 1, 1, 1, 11,8 11, 1,3 9, 1-/A, 8 7,1 1, 1,3 1,3 1,1 13,8 13,3 1, 11,6 1, 1-/, 19 7,9 16,1 1,9 1,9 1,8 1, 1,1 1, 13,6 1,6 11,3 1-/A, ,6 1, 1, 1, 1,7 1, 13, 11,8 1-/, ,7 17, 17, 17,3 16,9 16,3 1, 1, 13,1 1-/7 7, , 19,8 19,8 19,6 19, 18,9 18, 17, 16,1 1,8 1-/ ,3 3,,9,7,3 1,8 1,, 18,8 17, 16, Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT-8-1_pS-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller (3) Hydraulic efficiency of pump. 31

32 e-lnt 1, 1 SERIES (SINGLE OPERATION) HYDRAULIC PERFORMANCE TABLE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T ηp % l/s 1,3,16 7,8 3,3 3,7,71 8,3 6,98 73,6 81,3 89 P N m 3 /h kw mm (1) () (3) H = TOTAL HEAD METRES COLUMN OF WATER 1-16/, 18 6,1 6, 6, 6,,,1,1 1-16/ ,9 8, 8,3 7,7 6,,6 1-16/ 18 73, 1,3 1, 9,6 8,6 6,8,3 1-/, 73, 13, 1,8 1,3 11, 9, 7, 1-/7 7, 7 77, 17, 16,7 16,3 1, 1, 11,9 9, 1-/7 7, 3 7, 17, 17,1 16,6 1, 13,7 11, 7,7 1-/ ,1 1,9 1,9 1,, 18,8 16,6 13,7 1-31/ ,,9,8,3, 3,3 1,7 19,6 17, 13, 9,1 1-31/18 18, 91 7,8 8,9 8,7 8,3 7, 6,, 3,1,6 17, 13,6 1-31/ 38 76,1 3,7 3, 3,1 31, 3, 9,1 7,3,1,3 18,9 1,9 1-31/ , 39, 38,8 38, 37,9 37,1 36, 3, 3, 3, 7,1 3, 19, PUMP Q = DELIVERY TYPE Ø F T ηp % l/s 1 18,99 8,6 37,1 6,1,8 6,36 73,3 8, 91,8 1,6 11 P N m 3 /h kw mm (1) () (3) H = TOTAL HEAD METRES COLUMN OF WATER 1-/, 17 68,8 9,3 9,3 9, 8,7 7,9 6,8,7 3,9 1-/7 7, 19 7,6 11,9 11,7 11, 1, 9, 8, 6,6,9 1-/ ,9 1, 1, 1,7 1, 13, 1,3 1,9 9,1 7,1 1-/ , 16, 16, 16, 1, 1, 13, 11,3 9, 7,1 1-/ ,8,,3, 19, 18,7 17,6 16,1 1, 11,9 9, 1-31/18 18, 7 76,,,1,7, 3, 1,6 19,7 17,3 1, 1,8 1-31/ 8 77,1 8,1 8,1 7,8 7, 6,,8 3,,8 18, 1,9 1-31/ ,3 33,1 33,1 33, 3, 31,7 3, 8,8 6,8, 1,7 18,3 1-31/ , 36, 36,3 36, 3,9 3, 3, 3,7 3,8 8,,8,8 19,8 Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT-1-1_ps-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller 3) Hydraulic efficiency of pump. 3

33 e-lnt SERIES (PARALLEL OPERATION) HYDRAULIC PERFORMANCE RANGE AT Hz, POLES LNT (P) ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] H [m] Q [m 3 /h] Q [l/s] H [ft] A3_A_CH 33

34 e-lnt,, 6 SERIES (PARALLEL OPERATION) HYDRAULIC PERFORMANCE RANGE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T l/s,1 3,,,9,9 6,8 7,8 8,7 9,7 1,6 11,6 1, P N m 3 /h kw mm (1) () -1/B, 113 3,8 3,8 3,,9, -1/A, 13,,3 3,8 3,,3-1/, 133,,,8, 3,, -1/3,37 1 6, 6,3 6,,,8, 3, -16/3,37 1 7, 7,3 7, 6,,9,, -16/, 161 8, 8, 8, 7,8 7, 6,,, -16/7, ,7 9, 9, 8,7 8, 7,1 6,1, -/, 171 9, 8,9 8, 7,8 6,8,6 -/7, ,3 1,7 1, 9,8 9, 7,9 6,6 -/11 1,1 1, 13,3 13, 1, 11,9 11, 9,9 8, -/11 1,1 6 16,7 16,3 1,8 1,1 1,1 13, 11,6 1, -/1A 1, 6 16,7 16,3 1,8 1,1 1,1 13, 11,6 1, -/1 1, 39 18,8 18, 18, 17, 16, 1, 1, 1,8 -/, 9, 1,7 1,1, 19, 18, 17,1 1,6 13,9 1, PUMP TYPE Ø F T l/s,7,1, 6,8 8, 9,6 1,9 1,3 13,7 1, 16, 17,8 P N m 3 /h kw mm (1) () -1/A, 1 3, 3, 3,,6,1-1/, 118, 3,9 3,6 3,, -1/3,37 13,,8,6, 3,7 3, -1/, 13 6,,6,3,9,3 3,6-16/, 139 6,9 6, 6,3,9,,7 3,9-16/7,7 1 8, 8, 8, 7,7 7,3 6,7 6,,, -16/11 1,1 16 9,9 9,3 9,1 8,7 8, 7,6 6,8,9,9 -/11A 1, ,7 9,6 8,9 8,1 7,1,9 -/11 1, ,1 11, 1, 9,6 8,7 7,6 6, -/1 1, , 1, 11,9 11,1 1,3 9,3 8,1 6,8 -/1 1, 1 1, 1,9 1, 13,8 13, 11,9 1,7 9,3 -/A, 8 18, 17, 17, 16, 1,3 1, 1,9 11, -/, 3 1,1,3 19,8 19,1 18,3 17, 16,1 1,8 -/ ,8 3,, 1,9 1,1, 19,1 17,9 16, 1, PUMP TYPE Ø F T l/s,6 7 9,87 11,3 13, 1,78 18,1,,7,7 6,936 9,167 P N m 3 /h kw mm (1) () 6-1/3,37 118,7,3, 3,7 3,, 6-1/, 13,6,9,6, 3,6,9 6-1/7,7 1 6,9 6,,9,,, 3,6,7 6-1/11 1,1 18 7,9 7,1 6,8 6, 6,,,8 3,9 3, 6-16/11A 1,1 19 8, 7, 7, 6,8 6,3,7,8 3,9 6-16/11 1,1 17 9,6 8,7 8, 8, 7, 6,9 6,,3,3 6-16/1 1, 176 1,8 9,6 9, 8,8 8, 7,6 6,8,8,8 6-/1 1, ,1 1,8 1, 9,8 9,1 8, 7,1,9 6-/A, , 13,3 13, 1, 11,8 11, 1,1 9, 7,7 6-/, 9 1,3 1,8 1, 13,8 13, 1, 11,1 1, 8,7 6-/, 16,8 16,3 1,9 1, 1,6 13,7 1,6 11,3 9,9 6-/ ,8 18,3 17,9 17, 16,7 1,9 1,9 13,7 1,3 1,8 6-/ 6 3,1,3 1,9 1,3, 19,6 18,6 17,3 16, 1, 1,8 Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT---6_pP-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller. H = TOTAL HEAD METRES COLUMN OF WATER Q = DELIVERY H = TOTAL HEAD METRES COLUMN OF WATER Q = DELIVERY H = TOTAL HEAD METRES COLUMN OF WATER 3

35 e-lnt 8, 1 SERIES (PARALLEL OPERATION) HYDRAULIC PERFORMANCE RANGE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T l/s 7 11, 1,6 19,8 3,9 7,3 31,3 3,33 39,3 3,36 7,37 1 P N m 3 /h kw mm (1) () 8-16/11A 1,1 1 7, 6,8 6,6 6,,,6 3,6 8-16/1B 1, 1 7, 6,8 6,6 6,,,6 3,6 8-16/11 1,1 11 7,9 7, 6,8 6,,, 8-16/1A 1, 11 7,9 7, 6,8 6,,, 8-16/1 1, 19 8,8 8,1 7,7 7, 6,,,3 8-16/A, 17 1,7 1, 9,7 9, 8,6 7,8 6,7, 8-16/, 18 11,3 1,6 1,3 9,9 9,3 8, 7, 6,3 8-/, 189 1,3 1, 11, 1,8 9,9 8,8 7,6 8-/ ,7 13, 1,9 1,3 11, 1, 9,3 7,9 8-/ 16,9 16,7 16,3 1,7 1,9 1, 13, 11,8 1, 8,7 8-/A, 9 18,6 18,6 18,3 17,8 17,1 16, 1,1 13,9 1, 1,8 8-/, 3 1, 1,1,8, 19,8 19, 18, 16,8 1, 13,9 1, 8-/7 7, 8 3,8 3,7 3,3,8, 1,1, 18,8 17,3 1,8 1,1 PUMP TYPE Ø F T l/s 1 17,,8 7,3 3,33 37,3,38 7,,3 7, 6,7 68 P N m 3 /h kw mm (1) () 1-16/1 1, 1 6,7,9,7,,9, 3,3 1-16/A, 18 8, 7,1 6,8 6,,9,1,1 1-16/, 168 9,3 8,1 7,9 7, 7, 6,,, 1-16/ , 9,1 8,9 8,6 8,1 7,6 6,8,8,7 1-/ ,9 1, 1, 9,8 9,3 8, 7,1 1-/ 19 1,8 1,3 1,1 11,8 11,3 1,7 9,8 8,3 1-/A, 8 1,6 1,1 13,9 13,6 13, 1,7 1, 11,1 1-/, 19 16,3 1,6 1,3 1, 1, 13,9 13,1 1, 1-/A, 1 16, 1, 1,1 1,9 1,3 13, 1, 11, 1-/, 7 18,1 17, 17, 17, 16, 1,9 1, 13,9 1,8 1-/7 7, 1, 19,6 19, 19,3 19, 18, 17,7 16,7 1,6 1, 1-/ ,9,7,6, 1,9 1,3, 19, 18, 17, 16, Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT-8-1_pP-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller. H = TOTAL HEAD METRES COLUMN OF WATER Q = DELIVERY H = TOTAL HEAD METRES COLUMN OF WATER 3

36 e-lnt 1, 1 SERIES (PARALLEL OPERATION) HYDRAULIC PERFORMANCE TABLE AT Hz, POLES PUMP Q = DELIVERY TYPE Ø F T l/s 9,8 31,7,8 3,99 6,13 76,6 87, 98, 19,7 1,81 13 P N m 3 /h kw mm (1) () H = TOTAL HEAD METRES COLUMN OF WATER 1-16/, 18 6,1 6, 6,,7,8 3,6 1-16/ , 8,3 8, 7,,9,3 1-16/ 18 1, 1,3 1, 9,3 8, 6,6 1-/, 13,1 1,8 1, 11,9 1,9 9,3 7,3,7 1-/7 7, 7 17, 16,8 16, 16, 1,1 13,8 1,1 1, 8,1 1-/7 7, 3 17, 17,1 16,7 16, 1,8 13, 11, 8,8 1-/ ,9 1,9 1,6 1, 19,9 18, 16,6 1, 1-31/1 1 76,9,8,,8 3,9,8 1, 19,3 17, 1, 1-31/18 18, 91 8,9 8,6 8,3 7,8 7, 6,,,7, 17,6 1-31/ 38 3,6 3,3 31,9 31, 3,7 9,7 8, 6,8,8, 19,8 1-31/ ,3 38,8 38, 38, 37, 36,6 3, 3,1 3,3 3,3 7,9, PUMP Q = DELIVERY TYPE Ø F T l/s 36,9 1,76 67, 83,9 98,76 11, 13,1 1,8 161, 177, P N m 3 /h kw mm (1) () H = TOTAL HEAD METRES COLUMN OF WATER 1-/, 17 9, 9, 9,1 8,7 8, 6,9, 1-/7 7, 19 1, 11,6 11,1 1, 9, 8, 6,6 1-/ , 1,8 1, 13,8 13, 11,9 1,6 8,9 6,8 1-/ , 16, 1,6 1, 13,9 1, 1,7 8,6 1-/1 1 9,6,1 19,7 19,1 18,1 16,8 1,1 13,1 1,8 1-31/18 18, 7,3,1,6 3,7,,8 18,7 16,3 13,6 1-31/ 8 8, 7,9 7, 6,8,6,1,1 19,8 17,1 1, 1-31/ ,1 3,9 3,6 3, 31, 9,6 7,8,7 3,1, 17, 1-31/ ,6 36,3 36,1 3, 3,6 33,3 31,6 9,6 7,1, 1, 18, Hydraulic performances in compliance with ISO 996:1 - Grade 3B (ex ISO 996: Annex A) LNT-1-1_pP-en_a_th (1) Medium diameter of full impeller () Medium diameter of trimmed impeller. 36

37 e-lnt SERIES IDENTIFICATION OF GRAPH Max efficiency η η[%] [%] 1 Parallel operation Single pump operation 1 1 REF TYPE DESCRIPTION 1 Full Diameter impeller operating range Trimmed diameter impeller operating range 37

38 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT -1 ~ 9 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] 9.9 η[%] H[m] T/11 Ø113-1T/1 Ø13-1T/ Ø133-1T/3 Ø1 3 1 H [ft] 16 6 NPSH[m] 1 8-1T/3 Ø1 NPSH [ft] 6 8 Pp[kW] 3 1-1T/11 Ø113-1T/1 Ø13-1T/ Ø133-1T/3 Ø Q 7 [m 3 /h] Q [l/s] Pp[HP] LNT-1_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 38

39 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT -16 ~ 9 [rpm] ISO 996:1 - Grade 3B η[%] Q [Imp gpm] Q [US gpm] H[m] T/3 Ø1-16T/ Ø T/ Ø171 6 H [ft] NPSH[m] T/ Ø171 6 NPSH[ft] Pp[kW] T/3 Ø1-16T/ Ø T/ Ø Q 9 [m 3 /h] 1 1 Q [l/s] Pp[HP] LNE-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 39

40 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT - ~ 9 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q 3 [US gpm] η[%] H[m] T/ Ø171 -T/7 Ø -T/ Ø H [ft] NPSH[m] 1 8 -T/7 Ø NPSH [ft] 1 Pp[kW] 1 -T/ Ø171 -T/ Ø186 -T/7 Ø 1 1 Pp[HP] Q 7[m /h] Q [l/s] LNT-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

41 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT - ~ 9 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US 3gpm] 9 η[%] H[m] T/1 Ø9 -T/11 Ø39 -T/** Ø6 1 H [ft] NPSH[m] 1 1 -T/1 Ø9 NPSH [ft] 3 Pp[kW] 1 1 -T/1 Ø9 -T/11 Ø39 -T/** Ø Q 8 [m 3 /h] 1 1 **= 9. kw (/9) LNTE, **= 11 kw (/11A) LNTS 3 1 Q [l/s] Pp[HP] LNT-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 1

42 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT -1 ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] H[m] T/1 Ø1-1T/ Ø118-1T/3 Ø13-1T/ Ø H [ft] 8 6 NPSH[m] -1T/ Ø13 1 NPSH [ft] T/ Ø13 8 Pp[kW] -1T/1 Ø1-1T/ Ø118-1T/3 Ø13 6 Pp[HP] Q 1 [m 3 /h] 1 1 Q [l/s] LNT-1_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

43 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT -16 ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] H[m] T/7 Ø16-16T/ Ø1-16T/ Ø139 6 H [ft] NPSH[m] T/7 Ø16 6 NPSH [ft] Pp[kW] T/7 Ø16-16T/ Ø1-16T/ Ø Q 1 [m 3 /h] Q [l/s] Pp[HP] LNT-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 3

44 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT - ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] H[m] 3 1 -T/11 Ø199 -T/** Ø189 -T/7 Ø H [ft] 1 NPSH[m] 8 -T/11 Ø NPSH [ft] Pp[kW] T/11 Ø199 -T/** Ø189 -T/7 Ø Pp[HP] Q 13 [m 3 /h] Q [l/s] **= 9. kw (/9) LNTE, **= 11 kw (/11A) LNTS LNT-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

45 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT - ~ 9 [rpm] ISO 996:1 - Grade 3B η[%] Q [Imp gpm] Q [US gpm] H[m] T/ Ø7. -T/18 Ø3 -T/1 Ø8 -T/11 Ø1 1 1 H [ft] 1 3 NPSH[m] 1 -T/ Ø NPSH [ft] Pp[kW] 3 1 -T/ Ø7. -T/18 Ø3 -T/1 Ø8 -T/11 Ø Q 1 [m 3 /h] Q [l/s] Pp[HP] LNT-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

46 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 6-1 ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] 3 η[%] H[m] H [ft] 1 6-1T/3 Ø T/ Ø13 6-1T/7 Ø18 6-1T/ Ø1 16 NPSH[m] T/7 Ø18 NPSH [ft] Pp[kW] T/7 Ø18 6-1T/ Ø1 6-1T/ Ø T/3 Ø Q 18 [m 3 /h] Q [l/s] Pp[HP] LNT6-1_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

47 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 6-16 ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q 9 [US gpm] η[%] H[m] T/ T/** Ø T/7 Ø17 Ø19 6 H [ft] Pp[kW] NPSH[m] T/11 Ø T/11 Ø T/** Ø T/7 Ø NPSH [ft] Pp[HP] Q 1 [m 3 /h] 1 3 Q [l/s] **= 9. kw (/9) LNTE, **= 11 kw (/11A) LNTS LNT6-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

48 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 6- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q 9 [US gpm] 6 η[%] H[m] T/18 Ø9 6-T/1 Ø197 6-T/11 Ø179 1 H [ft] 1 6 NPSH[m] 1 6-T/18 Ø9 NPSH [ft] Pp[kW] T/18 Ø9 6-T/1 Ø197 6-T/11 Ø Pp[HP] Q [m 3 /h] 1 3 Q [l/s] LNT6-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 8

49 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 6- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] H[m] T/18 Ø 6-T/ Ø3 6-T/3 Ø6 1 1 H [ft] 1 6 NPSH[m] T/3 Ø6 NPSH[ft] Pp[kW] T/18 Ø 6-T/ Ø T/3 Ø Q [m 3 /h] Q [l/s] Pp[HP] LNT6-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 9

50 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 8-16 ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] H[m] T/7 Ø1 8-16T/18 Ø T/1 Ø T/11 Ø T/** Ø H [ft] 3 NPSH[m] T/18 Ø NPSH [ft] 3 Pp[kW] T/18 Ø T/1 Ø T/11 Ø T/** Ø T/7 Ø Q 3 [m 3 /h] **= 9. kw (/9) LNTE, **= 11 kw (/11A) LNTS 3 1 Q [l/s] Pp[HP] LNT8-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

51 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 8- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] H[m] T/3 Ø 8-T/ Ø199 8-T/18 Ø189 8-T/1 Ø177 H [ft] NPSH[m] T/3 Ø NPSH [ft] Pp[kW] T/3 Ø 8-T/ Ø199 8-T/18 Ø189 8-T/1 Ø Q 3 [m 3 /h] Q [l/s] Pp[HP] LNT8-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 1

52 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 8- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] 73.3 Q [US gpm] H[m] 3 8-T/37 Ø9 1 1 H [ft] 1 NPSH[m] T/37 Ø9 8 6 NPSH [ft] 1 Pp[kW] 6 8-T/37 Ø9 8 6 Pp[HP] Q [m 3 /h] Q [l/s] LNT8-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

53 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1-16 ~ 9 [rpm] ISO 996:1 - Grade 3B η[%] Q [Imp gpm] Q [US gpm] H[m] T/ Ø T/18 Ø T/1 Ø T/11 Ø1 6 H [ft] 6 NPSH[m] T/ Ø177 NPSH [ft] Pp[kW] T/ Ø T/18 Ø T/1 Ø T/11 Ø Q 36 [m 3 /h] Q [l/s] 3 1 Pp[HP] LNT1-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 3

54 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] 76. Q [US gpm] H[m] T/37 Ø8 1-T/3 1-T/ Ø19 Ø H [ft] Pp[kW] NPSH[m] T/37 Ø8 1-T/37 Ø8 1-T/3 Ø19 1-T/ Ø NPSH [ft] Pp[HP] Q [m 3 /h] Q [l/s] LNT1-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

55 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1- ~ 9 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] T/37 Ø1 H[m] 3 1 H [ft] 1 Pp[kW] NPSH[m] T/37 Ø1 1-T/37 Ø NPSH [ft] Pp[HP] Q [m 3 /h] Q [l/s] LNT1-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec.

56 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT -1 ~ 1 [rpm] ISO 996:1 - Grade 3B Q[Imp gpm] Q [US gpm] η[%] H[m] 3. 1 H [ft] 1-1T/A Ø13-1T/B Ø113-1T/3 Ø1-1T/ Ø133 1 NPSH[m] 3 1-1T/3 Ø1 1 NPSH[ft] Pp[kW] T/3 Ø1-1T/ Ø133-1T/A Ø13-1T/B Ø Q 3 [m 3 /h] Q [l/s] Pp[HP] LNT-1_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

57 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT -16 ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] 3 3 H[m] T/7 Ø171-16T/ Ø T/3 Ø1 1 1 H [ft] 3 1 NPSH[m] 1-16T/7 Ø171 NPSH[ft] Pp[kW] T/ Ø T/3 Ø1-16T/7 Ø Q [m 3 /h] Q [l/s] Pp[HP] LNT-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

58 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT - ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] H[m] NPSH[m] η[%] -T/11 Ø -T/7 Ø186 -T/ Ø171 -T/11 Ø Q [US gpm] H [ft] NPSH [ft] Pp[kW] T/11 Ø -T/7 Ø186 -T/ Ø Pp[HP] Q [m 3 /h] Q [l/s] LNT-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 8

59 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT - ~ 1 [rpm] ISO 996:1 - Grade 3B Q 18 [Imp gpm] 1 1 η[%] Q [US gpm] H[m] T/ -T/1 Ø9 Ø39 -T/** Ø6 3 H [ft] NPSH[m] -T/ Ø9 1 NPSH [ft] Pp[kW] 3 -T/ Ø9 -T/1 Ø39 -T/** Ø6 3 Pp[HP] Q [m 3 /h] Q [l/s] *= 1.1 kw (/11) LNTS *= 1. kw (/1A) LNTE LNT-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 9

60 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT -1 ~ 1 [rpm] ISO 996:1 - Grade 3B Q 16 [Imp gpm] η[%] Q [US gpm] H[m] T/ Ø118-1T/A Ø1-1T/3 Ø13-1T/ Ø13 1 H [ft] 3 NPSH[m] 1-1T/ Ø NPSH [ft].8.6-1t/ Ø Pp[kW].. -1T/A Ø1-1T/ Ø118-1T/3 Ø Pp[HP] Q [m /h] Q [l/s] LNT-1_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

61 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT -16 ~ 1 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] 9 6 η[%] H[m] T/ Ø139-16T/7 Ø1-16T/11 Ø H [ft] 6 NPSH[m] -16T/11 Ø16 1 NPSH [ft].. Pp[kW] T/7 Ø1-16T/ Ø139-16T/11 Ø Pp[HP] Q 6 [m 3 /h] Q [l/s] LNT-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 61

62 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT - ~ 1 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] η[%] H[m] 6 -T/11 Ø189 -T/11A Ø179 -T/1 Ø199 1 H [ft] 1 3 NPSH[m] 1 -T/1 Ø NPSH[ft] Pp[kW] T/1 Ø199 -T/11 Ø189 -T/11A Ø Q 6 [m 3 /h] Pp[HP] Q [l/s] LNT-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

63 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT - ~ 1 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] 8 η[%] H[m] T/3 Ø7. -T/ Ø3 -T/A Ø8 -T/1 Ø1 3 H [ft] 1 6 NPSH[m] -T/3 Ø NPSH [ft] 6 8 Pp[kW] 3 1 -T/3 Ø7. -T/ Ø3 -T/A Ø8 -T/1 Ø1 6 Pp[HP] Q 7 [m 3 /h] Q [l/s] LNT-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 63

64 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 6-1 ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] H[m] T/3 Ø T/ Ø13 6-1T/11 Ø18 6-1T/7 Ø1 1 H [ft] 1 NPSH[m] T/11 Ø18 1 NPSH [ft].. Pp[kW] T/11 Ø18 6-1T/7 Ø1 6-1T/ Ø13 6-1T/3 Ø Pp[HP] Q 9 [m 3 /h] 1 1 Q [l/s] LNT6-1_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

65 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 6-16 ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] H[m] T/11 Ø T/11A Ø T/1 Ø H [ft] 1 NPSH[m] T/1 Ø176 1 NPSH [ft] 3 Pp[kW] T/1 Ø T/11 Ø T/11A Ø Pp[HP] Q 1 [m 3 /h] 1 1 Q [l/s] LNT6-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 6

66 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 6- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] H[m] T/ Ø9 6-T/A Ø197 6-T/1 Ø179 1 H [ft] 6 NPSH[m] 6-T/ Ø9 1 1 NPSH [ft] Pp[kW] T/ Ø9 6-T/A Ø197 6-T/1 Ø Q 1 [m 3 /h] Pp[HP] Q [l/s] LNT6-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 66

67 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 6- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] 1 3 Q [US gpm] 8 η[%] H[m] T/ Ø6 6-T/3 Ø3 6-T/ Ø 3 H [ft] 1 NPSH[m] T/ Ø6 1 1 NPSH [ft] 7 Pp[kW] T/ Ø6 6-T/3 Ø3 6-T/ Ø 8 6 Pp[HP] Q 1 [m 3 /h] Q [l/s] LNT6-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 67

68 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 8-16 ~ 1 [rpm] ISO 996:1 - Grade 3B 1 3 Q [Imp gpm] Q 7 [US gpm] 1 η[%] H[m] T/** Ø1 8-16T/* Ø T/ Ø T/A Ø T/1 Ø H [ft] NPSH[m] T/ Ø NPSH[ft] Pp[kW] T/ Ø T/A Ø T/1 Ø T/* Ø T/** Ø1 3 1 Pp[HP] Q 16 [m 3 /h] *= 1.1 kw (/11) LNTS, *= 1. kw (/1A) LNTE; **= 1.1 kw (/11A) LNTS, **= 1. kw (/1B) LNTE Q [l/s] LNT8-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 68

69 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 8- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] Q [US gpm] η[%] H[m] T/ Ø 8-T/3 Ø199 8-T/ Ø189 1 H [ft] 1 3 NPSH[m] 8-T/ Ø 1 NPSH [ft] 7 Pp[kW] T/ Ø189 8-T/3 Ø199 8-T/ Ø Q 18 [m 3 /h] Q [l/s] 8 6 Pp[HP] LNT8-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 69

70 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 8- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η[%] Q [US gpm] H[m] 1 8-T/7 Ø8 8-T/ Ø3 8-T/A Ø9 3 H [ft] NPSH[m] 8-T/7 Ø8 1 NPSH [ft] 1 Pp[kW] 1 8-T/7 Ø8 8-T/ Ø3 8-T/A Ø9 1 1 Pp[HP] Q [m 3 /h] 1 3 Q [l/s] LNT8-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

71 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1-16 ~ 1 [rpm] ISO 996:1 - Grade 3B Q 8 [Imp gpm] Q [US gpm] 1 8 η[%] H[m] T/3 Ø T/ Ø T/A Ø T/1 Ø1 1 1 H [ft] NPSH[m] 1-16T/3 Ø NPSH [ft] Pp[kW] T/3 Ø T/ Ø T/A Ø T/1 Ø Q [m 3 /h] Pp[HP] Q [l/s] LNT1-16_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 71

72 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1- ~ 1 [rpm] ISO 996:1 - Grade 3B Q 9 [Imp gpm] η[%] Q [US gpm] T/ Ø T/A Ø8 3 H[m] T/ Ø19 1-T/3 Ø181 H [ft] NPSH[m] 6 1-T/ Ø19 1 NPSH [ft] Pp[kW] T/ Ø19 1-T/A Ø8 1-T/ Ø19 1-T/3 Ø Pp[HP] 1 1 Q [m 3 /h] Q [l/s] LNT1-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

73 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1- ~ 1 [rpm] ISO 996:1 - Grade 3B η[%] Q [Imp gpm] Q [US gpm] H[m] T/11 Ø9 1-T/7 Ø1 1-T/ Ø7 1-T/A Ø1 3 H [ft] 1 NPSH[m] 1 1-T/11 Ø9 6 NPSH [ft] Pp[kW] T/11 Ø9 1-T/7 Ø1 1-T/ Ø7 1-T/A Ø1 1 1 Q 3 [m 3 /h] Q [l/s] Pp[HP] LNT1-_P_A_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 73

74 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1-16 ~ 1 [rpm] ISO 996:1 - Grade 3B 7 1 Q [Imp gpm] Q [US gpm] 1 η [%] 3 H [m] H [ft] T/3 Ø T/ Ø T/ Ø NPSH [m] 1-16T/ Ø NPSH [ft] P [kw] P T/ Ø T/3 Ø T/ Ø [m³/h] Q [m³/h] Q [l/s] P LNT1-16_P_B_CH [HP] P The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

75 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] [US 17 gpm] Q [US gpm] H [m] η [%] H [ft] T/7 Ø7 3 3 NPSH [m] P [kw] P T/ Ø 1-T/ Ø 1-T/7 Ø7 1-T/7 Ø [m³/h] [l/s] Q [m³/h] Q [l/s] 1 1 NPSH [ft] P [HP] P LNT1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 7

76 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η [%] Q [US gpm] 8 7 H [m] H [ft] 1 1-T/11 Ø9 1-T/7 Ø NPSH [m] 8 1-T/11 Ø9 3 1 NPSH [ft] P [kw] P T/7 Ø3 1-T/11 Ø [m³/h] Q [m³/h] Q [l/s] P [HP] P LNT1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 76

77 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1-31 ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] H [m] η [%] Q [US gpm] 1-31T/3 Ø T/ Ø T/18 Ø T/1 Ø H [ft] 1 NPSH [m] T/3 Ø NPSH [ft] P [kw] P T/3 Ø T/ Ø T/18 Ø T/1 Ø [m³/h] [l/s] Q [m³/h] Q [l/s] P LNT1-31_P_B_CH [HP] P The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 77

78 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] η [%] Q [US gpm] H [m] H [ft] T/11 Ø 1-T/7 Ø19 1-T/ Ø NPSH [m] T/11 Ø 1-T/11 Ø NPSH [ft] P [kw] P T/7 Ø19 1-T/ Ø [m³/h] Q [m³/h] Q [l/s] P LNT1-_P_B_CH [HP] P The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 78

79 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1- ~ 1 [rpm] ISO 996:1 - Grade 3B Q [Imp gpm] 1 1 [Imp gpm] H [m] NPSH [m] P [kw] P [m³/h] 7 η [%] 1-T/11 Ø 1-T/11 Ø 1-T/1 Ø9 1-T/1 Ø9 1-T/1 Ø Q [US gpm] Q [m³/h] Q [l/s] H [ft] NPSH [ft] P [HP] P LNT1-_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 79

80 e-lnt SERIES OPERATING CHARACTERISTICS AT Hz, POLES LNT 1-31 ~ 1 [rpm] ISO 996:1 - Grade 3B 1 1 Q [Imp gpm] Q [US gpm] 13 H [m] η [%] H [ft] T/37 Ø T/3 Ø T/ Ø8 1-31T/18 Ø7 3 NPSH [m] P [kw] P T/37 Ø3 1-31T/37 9 Ø T/3 Ø T/ 6 Ø8 1-31T/18 Ø [m³/h] [l/s] Q [m³/h] Q [l/s] NPSH [ft] P [HP] P LNT1-31_P_B_CH The NPSH values are laboratory values; for practical use we suggest increasing these values by, m. These performances are valid for liquids with density ρ = 1, Kg/dm 3 and kinematic viscosity ν = 1 mm /sec. 8

81 DIMENSIONS AND WEIGHTS 81

82 LNTE,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 8

83 LNTE,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTE.. B H L k DND DNS b1 h1 h h3 l1 p x kg -1/11/S 7, /1/S 7, //P 7, /3/P 7, /3/P 7, /P 7, //P 7, //P 37, //P 37, /7/P 37, /9/P 37, /11/P 37, /1/P 37, /1/S //P /3/P //P //P //P /7/P /7/P 37, /9/P 37, /11/P 37, /11/P 37, /1/P 37, /18/P 37, //P 37, /3/P //P //P /7/P /7/P /9/P /11/P /11/P , /1/P , /18/P , /18/P , //P , /7/P /9/P /11/P /1/P /18/P /11/P /1/P /18/P //P NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTE--1_p-en_a_td 83

84 LNTE,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 8

85 LNTE,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTE.. B H L k DND DNS b1 h1 h h3 l1 p x kg -1/B/S 7, /A/S 7, //S 7, /3/S 7, /3/S 7, //S 7, /7/X 7, //S 37, /7/X 37, /11/P 37, /1A/P 37, /1/P 37, //P 37, /A/S //S /3/S //S //S /7/X /11/P /11A/P 37, /11/P 37, /1/P 37, /1/P 37, /A/P 37, //P 37, /3/P 37, /3/S //S /7/X /11/P /11A/P /11/P /1/P /1/P , /A/P , //P , //P , /3/P , //P , /1B/P /1A/P /1/P /A/P //P /1/P /A/P //P /3/P NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTE--1_p-en_a_td 8

86 LNTS,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 86

87 LNTS,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTS.. B H L k DND DNS b1 f h1 h h3 l1 p x kg -1/11/S 7, /1/S 7, //P 7, /3/P 7, /3/P 7, //P 7, //P 7, //P 37, //P 37, /7/P 37, /11A/P 37, /11/P 37, /1/P 37, /1/S //P /3/P //P //P //P /7/P /7/P 37, /11A/P 37, /11/P 37, /11/P 37, /1/P 37, /18/P 37, //P 37, /3/P //P //P /7/P /7/P /11A/P /11/P /11/P , /1/P , /18/P , /18/P , //P , /3/W , NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTS---6_p-en_a_td 87

88 LNTS,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 88

89 LNTS,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTS.. B H L k DND DNS b1 f h1 h h3 l1 p x kg -16//S 7, /7/X 7, //S 37, /7/X 37, /11/P 37, /11/P 37, /1/P 37, //P 37, //S //S /7/X /11/P /11A/P 37, /11/P 37, /1/P 37, /1/P 37, /A/P 37, //P 37, /3/P 37, //S /7/X /11/P /11A/P /11/P /1/P /1/P , /A/P , //P , //P , /3/P , //P , NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTS---6_p-en_a_td 89

90 LNTS 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 9

91 LNTS 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTS.. B H L k DND DNS b1 f h1 h h3 l1 p x kg 8-16/7/P /11A/P /11/P /1/P /18/P /18/P , //P , /3/W , /37/W , /11/P /1/P /18/P //P //P /3/W /37/W /37/W NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTS-8-1_p-en_a_td 91

92 LNTS 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 9

93 LNTS 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTS.. B H L k DND DNS b1 f h1 h h3 l1 p x kg 8-16/11A/P /11/P /1/P /A/P //P //P , /3/P , //P , /A/P , //P , /7/P , /1/P /A/P //P /3/P /3/P //P /A/P //P /A/P //P /7/P /11/P NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTS-8-1_p-en_a_td 93

94 LNTS 1, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES e f L x PM1 PM E Ø1 6 b b n n1 b3 b1 C C h1 DN D DN S h Flange Connections PM1 / PM 1/" E 1/" PM1..Pressure gauge connector PM..Pressure gauge connector E...Drain *)...Value C and D may vary from standard L DN df K D EN19-, PN 16 *) DN D K C df L x x3 LNTS-EN_A_DD 9

95 LNTS 1, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE LNTS.. DIMENSIONS (mm) WEIGHT (kg) DND DNS e f h1 h n1 n b1 b b3 b x L G 1-16//P /3/P //P //P /7/P /7/P /11/P /1/P /18/W //W /3/W //P /7/P /11/P /11/P /1/P /18/W //W /3/W /37/W NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTS-1-1_p-en_a_td 9

96 96

97 LNT..H (e-lnt WITH HYDROVAR) 97

98 LNT..H SERIES (e-lnt WITH HYDROVAR) Background and context For all pumping needs in commercial or residential building and in industry applications, the demand for intelligent pumping systems is constantly growing. Controlled systems offer many advantages: reduced operating costs for the lifetime of the pump, lower environmental impact, longer lifetime of piping systems and networks. For this reason, Lowara has developed the LNT..H: an intelligent pumping system which assures high level performance with energy consumption tailored to the system s demand. Benefits of e-lnt with HYDROVAR Saving: LNT..H transforms the LNT pumps into variable speed intelligent pumping systems. Thanks to the HYDROVAR, the speed of each pump varies so as to maintain a constant flow, a constant pressure, or a differential pressure. In doing so, at any point in time, the pump only receives the energy required. This in turns allows for considerable savings, especially for systems that have varying loads throughout the day. Key Features of the Hydrovar No need for additional pressure sensors: The LNT..H is fitted with a pressure transmitter or differential pressure transmitters, depending on the application. No need for special pumps or motors. No need for bypass or safety systems: The LNT..H will immediately switch off when demand drops to zero or when it exceeds maximum pump capacity; thus making installation of additional safety devices unnecessary. Anti-condensation device: The LNT..H is fitted with anti-condensation devices which switch on when the pump is in standby in order to prevent condensation forming in the unit. Easy installation and space-saving: LNT..H saves time and space during installation. The Hydrovar is delivered already mounted on the motor (for models up to kw). The hydrovar is kept cool by the motor fan and does not require a control panel. In order to function, only fuses on the supply line are needed (Check your local electrical installation regulations). A wall-mounted HYDROVAR version is available for higher power outputs (up to kw). Standard motors: LNT..H models are fitted with threephase standard TEFC motors with insulation class 1 (F). 98

99 LNT..H SERIES (e-lnt WITH HYDROVAR) The basic function of the HYDROVAR device is to control the pump to meet the system demands. HYDROVAR performs these functions by: 1) Measuring the system pressure or flow via a transmitter mounted on the pump s delivery side. ) Calculating the motor speed to maintain the correct flow or pressure. 3) Sending out a signal to the pump to start the motor, increase speed, decrease speed or stop. ) In the case of multiple pump installations, HYDROVAR will automatically provide for the cyclic changeover of the pumps starting sequence. Control for constant pressure In addition to these basic functions, HYDROVAR can perform controls only manageable by the most advanced computerized control systems. Some examples are: Stop the pump(s) at zero demand. Stop the pump(s) in case of water failure on the suction side (protection against dry running). Stop the pump if the required delivery exceeds the pump s capacity (protection against cavitation caused by excessive demand), or automatically switch on the next pump in a multiple series. Protect the pump and motor from over-voltage, undervoltage, overload, and earth fault. Vary the pump speed: acceleration and deceleration time. Compensate for increased flow resistance at high flow rates. Conduct automatic tests at set intervals. Monitor the converter and motor operating hours. Display all functions on an LCD in different languages (Italian, English, French, German, Spanish, Portuguese, Dutch). Send a signal to a remote control system which is proportional to the pressure and frequency. Communicate with another HYDROVAR or control system via an RS 8 interface. Control to match a system curve Control for constant flow Control according to an external signal 99

100 e-lnt..h SERIES LIST OF MODELS AT Hz, POLES SIZE kw VERSION SIZE kw LNTH.. LNTEH LNTSH LNTH.. LNTEH LNTSH -1/11 1,1 8-16/7 7, -1/1 1, 8-16/9 9, - -1/, 8-16/11A / / / /1 1-16/ 8-16/18 18, -16/, 8-/18 18, - -/ 8-/ - -/, 1-16/ /7 7, 1-16/1 1 -/9 9, /18 18, -/11A / -/ / - -/1 1-1/1 1, -1/, -1/3 3-1/ -16/ -16/, -16/7 7, -/7 7, -/9 9, - -/11A / / /1 1 -/18 18, -/ 6-1/ / 6-1/, 6-1/7 7, 6-16/7 7, 6-16/9 9, /11A / / /1 1 6-/18 18, 6-/18 18, 6-/ = Available LNTH_models-p-en_a_sc LEGEND VERSION LNTEH : Extended shaft with HYDROVAR (twin version). LNTSH : Stub shaft with HYDROVAR (twin version). 1

101 e-lnt..h SERIES LIST OF MODELS AT Hz, POLES SIZE kw VERSION SIZE kw LNTH.. LNTEH LNTSH LNTH.. LNTEH LNTSH -1/B, /11A 1,1 - -1/A, /1B 1, - -1/, /11 1,1 - -1/3, /1A 1, - -16/3, /1 1, -16/, 8-16/A, -16/7,7 8-16/, -/, 8-/, - -/7,7 8-/ /11 1,1 8-/ - -/11 1,1-8-/A, - -/1A 1, - 8-/, - -/1 1, 8-/7 7, - -/, 1-16/1 1, -1/A, /A, -1/, /, -1/3, /3 3-1/, 1-/ /, 1-/ - -16/7,7 1-/A, - -16/11 1,1 1-/, - -/11A 1,1 1-/A, - -/11 1,1 1-/, - -/1 1, 1-/7 7, - -/1 1, 1-/ /A, 1-16/, - -/, 1-16/ / / - 6-1/3,37-1-/, - 6-1/, 1-/7 7, - 6-1/7,7 1-/7 7, - 6-1/11 1,1 1-/ /11A 1,1 1-31/ /11 1,1 1-31/18 18, /1 1, 1-31/ - 6-/1 1, 1-/, - 6-/A, 1-/7 7, - 6-/, 1-/ /, 1-/ /3 3 1-/1 1-6-/ 1-31/18 18, / - = Available LNTH_models-p-en_a_sc VERSION 11

102 LNTEH,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 1

103 LNTEH,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTEH.. B H L k ØF DND DNS b1 h1 h h3 l1 p x kg -1/11/S , -1/1/S , -1//P , -1/3/P , -16/3/P , -16/P , -16//P ,1 -//P , -//P ,1 -/7/P ,1 -/9/P ,1 -/11/P ,1 -/1/P /1/S , -1//P , -1/3/P , -1//P , -16//P , -16//P ,1-16/7/P ,1 -/7/P ,1 -/9/P ,1 -/11/P ,1 -/11/P ,1 -/1/P /18/P //P /3/P , 6-1//P , 6-1//P ,1 6-1/7/P ,1 6-16/7/P ,1 6-16/9/P ,1 6-16/11/P ,1 6-/11/P ,1 6-/1/P /18/P /18/P //P /7/P ,1 8-16/9/P ,1 8-16/11/P ,1 8-16/1/P /18/P /11/P /1/P /18/P //P NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTEH--1_p-en_a_td 13

104 LNTEH,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 1

105 LNTEH,, 6, 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTEH.. B H L k ØF DND DNS b1 h1 h h3 l1 p x kg -1/B/S , -1/A/S , -1//S , -1/3/S , -16/3/S , -16//S , -16/7/X , -//S , -/7/X , -/11/P , -/1A/P , -/1/P , -//P , -1/A/S , -1//S , -1/3/S , -1//S , -16//S , -16/7/X , -16/11/P , -/11A/P , -/11/P , -/1/P , -/1/P , -/A/P , -//P , -/3/P , 6-1/3/S , 6-1//S , 6-1/7/X , 6-1/11/P , 6-16/11A/P , 6-16/11/P , 6-16/1/P , 6-/1/P , 6-/A/P , 6-//P , 6-//P , 6-/3/P , 6-//P , 8-16/1B/P , 8-16/1A/P , 8-16/1/P , 8-16/A/P , 8-16//P , 1-16/1/P , 1-16/A/P , 1-16//P , 1-16/3/P , NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTE--1_p-en_a_td 1

106 LNTSH,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 16

107 LNTSH,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTSH.. B H L k ØF DND DNS b1 f h1 h h3 l1 p x kg -1/11/S , -1/1/S , -1//P , -1/3/P , -16/3/P , -16//P , -16//P ,1 -//P , -//P ,1 -/7/P ,1 -/11A/P ,1 -/11/P ,1 -/1/P /1/S , -1//P , -1/3/P , -1//P , -16//P , -16//P ,1-16/7/P ,1 -/7/P ,1 -/11A/P ,1 -/11/P ,1 -/11/P ,1 -/1/P /18/P //P /3/P , 6-1//P , 6-1//P ,1 6-1/7/P ,1 6-16/7/P ,1 6-16/11A/P ,1 6-16/11/P ,1 6-/11/P ,1 6-/1/P /18/P /18/P //P NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTSH---6_p-en_a_td 17

108 LNTSH,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 18

109 LNTSH,, 6 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTSH.. B H L k ØF DND DNS b1 f h1 h h3 l1 p x kg -16//S , -16/7/X , -//S , -/7/X , -/11/P , -/11/P , -/1/P , -//P , -1//S , -16//S , -16/7/X , -16/11/P , -/11A/P , -/11/P , -/1/P , -/1/P , -/A/P , -//P , -/3/P , 6-1//S , 6-1/7/X , 6-1/11/P , 6-16/11A/P , 6-16/11/P , 6-16/1/P , 6-/1/P , 6-/A/P , 6-//P , 6-//P , 6-/3/P , 6-//P , NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTSH---6_p-en_a_td 19

110 LNTSH 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 11

111 LNTSH 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTSH.. B H L k ØF DND DNS b1 f h1 h h3 l1 p x kg 8-16/7/P ,1 8-16/11A/P ,1 8-16/11/P ,1 8-16/1/P /18/P /18/P //P /11/P ,1 1-16/1/P /18/P //P //P NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTSH-8-1_p-en_a_td 111

112 LNTSH 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 11

113 LNTSH 8, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE DIMENSIONS (mm) WEIGHT LNTSH.. B H L k ØF DND DNS b1 f h1 h h3 l1 p x kg 8-16/11A/P , 8-16/11/P , 8-16/1/P , 8-16/A/P , 8-16//P , 8-//P , 8-/3/P , 8-//P , 8-/A/P ,1 8-//P ,1 8-/7/P ,1 1-16/1/P , 1-16/A/P , 1-16//P , 1-16/3/P , 1-/3/P , 1-//P , 1-/A/P ,1 1-//P ,1 1-/A/P ,1 1-//P ,1 1-/7/P ,1 1-/11/P ,1 NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTSH-8-1_p-en_a_td 113

114 LNTSH 1, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES 11

115 LNTSH 1, 1 SERIES DIMENSIONS AND WEIGHTS AT Hz, POLES PUMP TYPE LNTSH.. DIMENSIONS (mm) WEIGHT (kg) DND DNS e f h1 h n1 n b1 b b3 b x L ØF G 1-16//P , 1-16/3/P , 1-16//P , 1-//P ,1 1-/7/P ,1 1-/7/P ,1 1-/11/P ,1 1-31/1/P /18/W //W //P ,1 1-/7/P ,1 1-/11/P ,1 1-/11/P ,1 1-/1/P /18/W //W NOTE: Pumps supplied with flanges according to EN 19- as standard. For flanges dimensions see drawing. LNTSH-1-1_p-en_a_td 11

116 116

117 ACCESSORIES 117

118 LNT SERIES ROUND THREADED COUNTERFLANGES KIT ACCORDING TO EN 19-1 CODE DIMENSIONS (mm) HOLES DN KIT ø C ø A B ø D H ø F N PN Rp 1½ Rp Rp ½ Rp Rp Lne-Lnt-ctf-tonde-f-en_a_td LNT SERIES ROUND WELD COUNTERFLANGES KIT ACCORDING TO EN 19-1 CODE DIMENSIONS (mm) HOLES DN KIT ø C ø A B ø D ø F N PN , , , , , , Lne-Lnt-ctf-tonde-s-en_a_td LNT ( 1) SERIES BLIND FLANGE KIT FLANGE KIT PUMP TYPE CODE ø D LNT-1 / LNT-16 LNT-1 / LNT-16 LNT6-1 / LNT LNT- / LNT- LNT- / LNT- LNT6- / LNT6- LNT8-16 LNT8- / LNT8- LNT1-16 LNT1- / LNT LNT-flangia-cieca-en_a_td 118

119 LNT 1, 1 SERIES BLIND FLANGE KIT FLANGE KIT POMPA TIPO CODE ø D LNTS 1-16 LNTS 1- LNTS 1- LNTS 1- LNTS 1- LNTS 1-31 LNTS LNTS-BLFL-en_a_td ØD LNTS-BLFL-EN_A_DD LNT ( 1) SERIES MOUNTING BASE KIT PUMP (LNT) CODE DIMENSIONS (mm) SIZE KIT a a1 c h m m1 n n1-1 / / / / / / / / LNT-piede-en_a_td 119

120 LNT 1, 1 SERIES MOUNTING BASE KIT ELETTROPOMPE SERIE LNTS 1-1 PIEDE DI APPOGGIO PUMP CODE DIMENSIONS (mm TYPE KIT n1 n LNTS LNTS LNTS LNTS LNTS LNTS LNTS LNTS1-1-base-en_a_td 1

121 REPORTS AND DECLARATIONS 11

122 REPORTS AND DECLARATIONS i) Test reports a) Factory Test Report (Lowara identity code: 1A) (not available for all pump types; contact Customer Service in advance) - Test report compiled at the end of the assembly line, including flow-head performance test (ISO 996:1 Grade 3B) and tightness test. b) Audit Test Report (Lowara identity code: 1B) - Test report for electric pumps compiled in the test room, comprising flow-head-pump input-pump efficiency performance test (ISO 996:1 Grade 3B) c) NPSH Test Report (Lowara identity code: 1A / CTF-NP) (unavailable for submerged or submergible pumps) - Test report for electric pumps compiled in the test room, comprising flow-npsh performance test (ISO 996:1 Grade 3B) d) Noise Test Report (Lowara identity code: 1A / CTF-RM) (unavailable for submerged pumps) - Report indicating sound pressure and power measurements (EN ISO 361, EN ISO 113, EN ISO 871) using the intensimetric (EN ISO 961-1, EN ISO 961-), or phonometric method. e) Vibration Test Report (unavailable for submerged or submergible pumps) - Report indicating vibration measurements (ISO ) ii) Declaration of product conformity with the technical requirements indicated in the order a) EN 1: - type.1 (Lowara identity code: CTF-1) - does not include test results on supplied or similar products. b) EN 1: - type. (Lowara identity code: CTF-) - includes test results (materials certificates) on similar products. c) EN 1: - type 3.1 (Lowara identity code: 1A / CTF-31 or 1B / CTF-31) - includes test report (Factory Test Report or Audit Test Report), list of materials, EC Declaration of Conformity (in addition to the one accompanying the product), certificates / declarations concerning materials in contact with water. iii) Issue of a further EC Declaration of Conformity, - in addition to the one accompanying the product, it comprises references to European law and the main technical standards (e.g.: MD 6//EC, EMCD /18/EC, ErP 9/1/EC). N.B.: if the request is made after receipt of the product, communicate the code (name) and serial number (date + progressive number). iv) Manufacturer s declaration of conformity - relative to one of more types of products without indicating specific codes and serial numbers. v) Other certificates and/or documentation on request - subject to availability or feasibility. vi) Duplication of certificates and/or documentation on request - subject to availability or feasibility. 1

123 TECHNICAL APPENDIX 13

124 NPSH The minimum operating values that can be reached at the pump suction end are limited by the onset of cavitation. Cavitation is the formation of vapour-filled cavities within liquids where the pressure is locally reduced to a critical value, or where the local pressure is equal to, or just below the vapour pressure of the liquid. The vapour-filled cavities flow with the current and when they reach a higher pressure area the vapour contained in the cavities condenses. The cavities collide, generating pressure waves that are transmitted to the walls. These, being subjected to stress cycles, gradually become deformed and yield due to fatigue. This phenomenon, characterized by a metallic noise produced by the hammering on the pipe walls, is called incipient cavitation. The damage caused by cavitation may be magnified by electrochemical corrosion and a local rise in temperature due to the plastic deformation of the walls. The materials that offer the highest resistance to heat and corrosion are alloy steels, especially austenitic steel. The conditions that trigger cavitation may be assessed by calculating the total net suction head, referred to in technical literature with the acronym NPSH (Net Positive Suction Head). The NPSH represents the total energy (expressed in m.) of the liquid measured at suction under conditions of incipient cavitation, excluding the vapour pressure (expressed in m.) that the liquid has at the pump inlet. To find the static height hz at which to install the machine under safe conditions, the following formula must be verified: hp + hz (NPSHr +.) + hf + hpv where: hp is the absolute pressure applied to the free liquid surface in the suction tank, expressed in m. of liquid; hp is the quotient between the barometric pressure and the specific weight of the liquid. hz is the suction lift between the pump axis and the free liquid surface in the suction tank, expressed in m.; hz is negative when the liquid level is lower than the pump axis. hf is the flow resistance in the suction line and its accessories, such as: fittings, foot valve, gate valve, elbows, etc. hpv is the vapour pressure of the liquid at the operating temperature, expressed in m. of liquid. hpv is the quotient between the Pv vapour pressure and the liquid s specific weight., is the safety factor. 1 The maximum possible suction head for installation depends on the value of the atmospheric pressure (i.e. the elevation above sea level at which the pump is installed) and the temperature of the liquid. To help the user, with reference to water temperature ( C) and to the elevation above sea level, the following tables show the drop in hydraulic pressure head in relation to the elevation above sea level, and the suction loss in relation to temperature. Water temperature ( C) Suction loss (m),,7,, 7, 1, 1, Elevation above sea level (m) Suction loss (m), 1,1 1,6,,7 3,3 Friction loss is shown in the tables at pages of this catalogue. To reduce it to a minimum, especially in cases of high suction head (over - m.) or within the operating limits with high flow rates, we recommend using a suction line having a larger diameter than that of the pump s suction port. It is always a good idea to position the pump as close as possible to the liquid to be pumped. Make the following calculation: Liquid: water at ~1 C γ = 1 kg/dm 3 Flow rate required: m 3 /h Head for required delivery: 7 m. Suction lift: 3, m. The selection is an 33SV3G7T pump whose NPSH required value is, at m 3 /h, of m. For water at 1 C hp = Pa / γ = 1,33m, hpv = Pv / γ =,17m (,171 bar) The Hf flow resistance in the suction line with foot valves is ~ 1, m. By substituting the parameters in formula 1 with the numeric values above, we have: 1,33 + (-3,) ( +,) + 1, +,17 from which we have: 6,8 > 3,9 The relation is therefore verified. TECHNICAL APPENDIX 1

125 VAPOUR PRESSURE VAPOUR PRESSURE ps AND ρ DENSITY OF WATER TABLE t T ps ρ t T ps ρ t T ps ρ C K bar kg/dm 3 C K bar kg/dm 3 C K bar kg/dm 3 73,1,611, ,1,171, ,1 1,98,99 1 7,1,67, ,1,1611, ,1,11,91 7,1,76, ,1,17313, ,1,, ,1,78, ,1,1817, ,1,3933, ,1,813 1, 9 33,1,1916, ,1,3,936 78,1,87 1, 6 333,1,199, ,1,713, ,1,93 1, 61 33,1,86,986 13,1,867, ,1,11, ,1,18, ,1 3,1, ,1,17, ,1,86, ,1 3,3,99 9 8,1,117, ,1,391, ,1 3,1, ,1,17, ,1,1, ,1 3,61, ,1,131, ,1,61, ,1,1,91 1 8,1,11, ,1,733, ,1,33, ,1,197, ,1,86, ,1 6,181, ,1,197, ,1,98, ,1 7,8,9 1 88,1,17, ,1,3116, ,1 7,9, ,1,1817, ,1,33, ,1 8,9, ,1,1936, ,1,3396, ,1 1,7, ,1,6, ,1,33, ,1 11,33, ,1,196, ,1,3696, ,1 1,1,876 93,1,337, ,1,38, ,1 13,987,87 1 9,1,8, ,1,19,971 73,1 1,,867 9,1,6, ,1,189,973 78,1 17,3, ,1,88, ,1,36, ,1 19,77,88 97,1,98, ,1,7, ,1 1,6,867 98,1,3166, ,1,736, ,1 3,198, ,1,336, ,1,931,971 98,1,1, ,1,36, ,1,133,97 3 3,1 7,976, ,1,3778, ,1,3, ,1 3,63,8 9 3,1,, ,1,7, ,1 33,78, ,1,1, ,1,78,968 18,1 36,3, ,1,91, ,1,611,9678 3,1 39,776, ,1,73, ,1,69,9671 8,1 3,6, ,1,9, ,1,69, ,1 6,93, ,1,318, ,1,679, ,1,877, ,1,6, ,1,711,96 7 3,1,8, ,1,9, ,1,781,96 7 8,1 9,96, ,1,67, ,1,761, ,1 6,, ,1,66, ,1,789, ,1 69,186, ,1,6991, ,1,816, ,1 7,61, ,1,737, ,1,83, ,1 8,37, ,1,7777, ,1,8769, ,1 8,97,71 31,1,8198, ,1,99, ,1 9,1, ,1,9639, ,1,93, ,1 98,7, ,1,91, ,1,9776, ,1 1,61, ,1,98, ,1 1,133, ,1 11,89, ,1,186, ,1 1,878, ,1 1,6,61 7 3,1,161, ,1 1,1668, ,1 18,63,6 8 31,1,1116, ,1 1,, ,1 16,,61 9 3,1,11736, ,1 1,339,9 3 63,1 16,3,73 33,1,133, ,1 1,37, ,1 186,7,7 1 3,1,1961, ,1 1,316, ,1 1,,18 3,1,13613, ,1 1,636,976 37,1 67,3 1,, ,1,193, ,1 1,76,96 37,1,1, ,1 1,868,9 G-at_npsh_b_sc 1 TECHNICAL APPENDIX

126 TABLE OF FLOW RESISTANCE IN 1 m OF STRAIGHT CAST IRON PIPELINE (HAZEN-WILLIAMS FORMULA C=1) FLOW RATE NOMINAL DIAMETER in mm and inches m 3 /h l/min /" 3/" 1" 1 1/" 1 1/" 1/" 3" " " 6" 7" 8" 1" 1" 1" 16",6 1 v,9,3,3,1,13 hr 16 3,9 1,33,,13 The hr values must be multiplied by:,9 1 v 1,,8,1,31,,71 for galvanized or painted steel pipes hr 33,9 8,3,8,8,9, for stainless steel or copper pipes 1, v 1,89 1,6,68,1,7,17,7 for PVC or PE pipes hr 7,7 1,1,79 1,,9,16 1, v,36 1,33,8,,33,1 hr 87, 1, 7,,18,73, 1,8 3 v,83 1,9 1,,6,, hr 1 3,1 1,1 3, 1,3,3,1 3 v 3,3 1,86 1,19,73,6,3 hr 16, 13,,6 1,37,6, v,1 1,36,83,3,3, hr 1, 17,3,19 1,7,9,16 3 v,6 1,7 1,,66,, hr 77, 6,1 7,8,6,89, 3,6 6 v 3,18, 1,,8,1,3 hr 18 36,6 11, 3,71 1,,3, 7 v 3,7,38 1,,93,9,3 hr 1 8,7 1,6,93 1,66,6,8 8 v,,7 1,66 1,6,68, hr 18 6,3 18,7 6,3,13,9, v v 3,6 3, 1,87,7 1,19 1,33,76,8,,,3,33 hr hr 77, 9,1 3,3 8,3 7,8 9,,6 3,,7,9,7,33 7, 1 v,,9 1,66 1,6,63,1 hr 1,8 1,,86 1,36,9 9 1 v 3,11 1,99 1,7,7,,3 hr 9,9, 6,8 1,9,69,3 1, 17 v 3,63,3 1,9,88,8,37 hr 79,7 6,9 9,7,3,9,31 1 v,1,6 1,7 1,1,66, hr 1 3, 11,6 3,3 1,18, v v,18 3,98 3,3,,1 1,1 1,6 1,,83,6,3,1,3 hr hr 1 7,8,,6 17, 6,8,89,9 1,78,8,6,8, v v v,31 6,63,1 3,, 3,,1,1 1,99 1,33 1,66 1,7,8 1,6,8,,68,7,38,7, hr hr hr ,6 1,8 63,,7 11,66 17,6 8,98, 6,1 3,3 1,3,16 1,,8,73,,,3, 7 v,9 3,,3 1,9,9,66,9 hr 118 3,8 11,9,3 1,36,6, v v 6,79 7,6,,,6,99 1,7 1,91 1,9 1,,7,8,,6 hr hr ,,3 1,3 19,,16 6,1 1,7,16,7,89,3, 6 1 v,3 3,3,1 1,36,9,69,3 hr 63, 3,1 7,79,63 1,8,1,7 7 1 v 6,8,1,6 1,7 1,18,87,66 hr 96, 3,9 11,8 3,97 1,63,77, 9 1 v 7,,98 3,18, 1, 1,,8 hr 13 8,9 16,,7,9 1,8, v 8,79,81 3,7,38 1,6 1,1,93 hr 179 6,1 1,9 7, 3, 1,,7 1 v 6,63,,7 1,89 1,39 1,6,68 hr 83,3 8,1 9,8 3,9 1,8,96,3 1 v 8,9,31 3,,36 1,73 1,33,8 hr 16, 1,3,89,78 1,, v 6,37,8,83,8 1,9 1,,71 hr 9,,1 8,6 3,9,3,69,8 1 3 v 7,3,76 3,3,3 1,86 1,19,83 hr 79,1 6,7 11,,18,71,91,38 v 8,9, 3,77,77,1 1,36,9 hr 11 3, 1,1 6,6 3,6 1,17,8 3 v 6,79,7 3,7,6 1,7 1,18 hr 1,6 1, 1,,3 1,77, v 8,1,66,16 3,18, 1, hr 7,3 9,8 1,1 7,33,7 1, 7 v 6,61,8 3,7,38 1,6 1,1 hr 39,6 18,7 9,7 3,9 1,3, v v 7, 8,9, 6,,,78,7 3,6 1,89,1 1,39 1,6 1,19 hr hr,7 63, 3,9 9,8 1,9 1,,1, 1,73,16,8 1,,3 6 1 G-at-pct-en_a_th v 6,93,31 3,,36 1,73 1,33 hr 36, 18,9 6,36,6 1,,6 hr = flow resistance for 1 m of straight pipeline (m) V = water speed (m/s) TECHNICAL APPENDIX 16

127 FLOW RESISTANCE TABLE OF FLOW RESISTANCE IN BENDS, VALVES AND GATES The flow resistance is calculated using the equivalent pipeline length method according to the table below: ACCESSORY TYPE Equivalent pipeline length (m) bend,,,,,6,6,9 1,1 1, 1,9,,8 9 bend,,6,9 1,1 1,3 1,,1,6 3, 3,9,7,8 9 smooth bend,,,,6,9 1,1 1,3 1,7 1,9,8 3, 3,9 Union tee or cross 1,1 1,3 1,7,1,6 3,,3,3 6, 7, 1,7 1,8 Gate - - -,,,,,,6,9 1,1 1,3 Non return valve 1,1 1, 1,9, 3, 3,,7,9 7, 9,6 11,8 13,9 DN G-a-pcv-en_a_th The table is valid for the Hazen Williams coefficient C=1 (cast iron pipework); for steel pipework, multiply the values by 1,1; for stainless steel, copper and coated cast iron pipework, multiply the values by 1,8; When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of flow resistance. The values given are guideline values which are bound to vary slightly according to the model, especially for gate valves and non-return valves, for which it is a good idea to check the values supplied by manufacturers. 17 TECHNICAL APPENDIX

128 VOLUMETRIC CAPACITY Litres Cubic metres Cubic feet Cubic feet Imperial gallon U.S. gallon per minute per hour per hour per minute per minute per minute l/min m 3 /h ft 3 /h ft 3 /min Imp. gal/min US gal/min 1,,6,1189,33,,6 16,6667 1, 3,317,886 3,666,9,719,83 1,,167,138,17 8,3168 1,699 6, 1, 6,88 7,8,61,78 9,636,16 1, 1,9 3,78,71 8,8,1337,837 1, PRESSURE AND HEAD Newton per kilo Pascal bar Pound force per Metre Millimetre of square metre square inch of water mercury N/m kpa bar psi m H O mm Hg 1,,1 1 x 1-1, x 1-1, x 1 -,7 1, 1,,1,1,1 7,6 1 x 1 1, 1, 1,38 1,197 7, ,77 6,898,689 1,,731 1, ,6 9,867,981 1,3 1, 73,61 133,3,1333,13,193,136 1, LENGTH Millimetre Centimetre Metre Inch Foot Yard VOLUME mm cm m in ft yd 1,,1,1,39,33,11 1, 1,,1,3937,38,19 1, 1, 1, 39,371 3,88 1,936,,, 1,,833,78 3,8 3,8,38 1, 1,, , 91,,91 36, 3, 1, Cubic metre Litre Millilitre Imperial gallon U.S. gallon Cubic foot m 3 L ml imp. gal. US gal. ft 3 1, 1, 1 x ,969 6,17 3,317,1 1, 1,,,6,33 1 x 1-6,1 1,, x 1 -,6 x 1-3,3 x 1 -,,61 6,87 1, 1,9,16,38 3, ,1,837 1,,1337,83 8, ,866 6,88 7,8 1, TEMPERATURE Water Kelvin Celsius Fahrenheit K C F icing 73,1, 3, boiling 373,1 1, 1, F = C C = ( F 3) 9 G-at_pp-en_b_sc TECHNICAL APPENDIX 18

129 FURTHER PRODUCT SELECTION AND DOCUMENTATION Xylect TM Xylect TM is pump solution selection software with an extensive online database of product information across the entire Lowara range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara products. The search can be made by: Application Product type Duty point Xylect TM gives a detailed output: List with search results Performance curves (flow, head, power, efficiency, NPSH) Motor data Dimensional drawings Options Data sheet printouts Document downloads incl dxf files The search by application guides users not familiar with the product range to the right choice. 19 TECHNICAL APPENDIX

130 FURTHER PRODUCT SELECTION AND DOCUMENTATION Xylect TM The detailed output makes it easy to select the optimal pump from the given alternatives. The best way to work with Xylect TM is to create a personal account. This makes it possible to: Set own standard units Create and save projects Share projects with other Xylect TM users Every user have a My Xylect space, where all projects are saved. For more information about Xylect TM please contact our sales network or visit Dimensional drawings appear on the screen and can be downloaded in dxf format. TECHNICAL APPENDIX 13

50 Hz. e-lne Series SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC

50 Hz. e-lne Series SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC Hz e-lne Series SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS ErP 9/1/EC Cod. 191731 Rev. D Ed./1 Xylect TM Xylect TM is a pump solution software with an extensive online database of product information

More information

FH SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz

FH SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz 50 Hz FH Series CENTRIFUGAL ELECTRIC PUMPS MANUFACTURED TO STANDARD EN 733 EQUIPPED WITH IE2 MOTORS COMPLYING WITH REGULATION (EC) no. 640/2009 Cod. 191002441 Rev ev.a.a Ed.11/2011 FH SERIES HYDRAULIC

More information

Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series

Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733 MARKET SECTORS The Lowara SH series pumps are used for water and clean liquid circulation in heating, ventilating and

More information

50 Hz. SH Series CENTRIFUGAL ELECTRIC PUMPS MADE OF AISI 316 STAINLESS STEEL IN COMPLIANCE WITH EN 733. ErP 2009/125/EC. Cod.

50 Hz. SH Series CENTRIFUGAL ELECTRIC PUMPS MADE OF AISI 316 STAINLESS STEEL IN COMPLIANCE WITH EN 733. ErP 2009/125/EC. Cod. 50 Hz SH Series CENTRIFUGAL ELECTRIC PUMPS MADE OF AISI 316 STAINLESS STEEL IN COMPLIANCE WITH EN 733 ErP 2009/125/EC Cod. 191002941 Rev ev.d.d Ed.08/2013 SH SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz

More information

SVI SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz

SVI SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz 50 Hz SVI Series 2, 4, 8, 16, 33, 46, 66, 92 SUBMERSIBLE VERTICAL ELECTRIC PUMPS EQUIPPED WITH IE2 MOTORS COMPLYING WITH REGULATION (EC) no. 640/2009 Cod. 191002451 Rev ev.a.a Ed.01/2012 SVI SERIES HYDRAULIC

More information

GSH SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz

GSH SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz 50 Hz GSH Series CENTRIFUGAL ELECTRIC PUMPS MADE OF AISI 316 STAINLESS STEEL IN COMPLIANCE WITH EN 733, EQUIPPED WITH IE2/IE3 MOTORS COMPLYING WITH REGULATION (EC) no. 640/2009 Cod. G91002941 Rev ev.b.b

More information

50 Hz. e-lne Series 125, 150 SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC

50 Hz. e-lne Series 125, 150 SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. ErP 2009/125/EC 50 Hz e-lne Series 125, 150 SINGLE IN-LINE ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS ErP 09/125/EC Cod. 1907431 Rev. A Ed.11/14 Xylect TM Xylect TM is a pump solution software with an extensive online database

More information

SVI Series 2, 4, 8, 16, 33, 46, 66, Hz

SVI Series 2, 4, 8, 16, 33, 46, 66, Hz 60 Hz SVI Series 2, 4, 8, 16, 33, 46, 66, 92 SUBMERSIBLE VERTICAL ELECTRIC PUMPS EQUIPPED WITH IE2/IE3 MOTORS COMPLYING WITH REGULATION (EC) no. 640/2009 Cod. 191002091 Rev ev.b.b Ed.06/2012 SVI SERIES

More information

Lenntech. FC-FCT Series. 50 Hz. Tel Fax

Lenntech. FC-FCT Series. 50 Hz. Tel Fax 50 Hz FC-FCT Series Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 IN-LINE ELECTRIC PUMPS SINGLE AND TWIN EQUIPPED WITH IE2/IE3 MOTORS COMPLYING WITH REGULATION (EC)

More information

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733 SH Series 60 Hz SERIE SH HYDRAULIC PERFORMANCE RANGE AT 60 Hz WEB 10-2006 2 CONTENTS 5 Specifications... 6

More information

TDB - TDV Series TBD 22, 35, 58, 78, 120, 170 TDV 120, 170, 220, 280

TDB - TDV Series TBD 22, 35, 58, 78, 120, 170 TDV 120, 170, 220, 280 50 Hz TDB - TDV Series TBD 22, 35, 58, 78, 120, 170 TDV 120, 170, 220, 280 VERTICAL MULTISTAGE ELECTRIC PUMPS EQUIPPED WITH IE2 MOTORS COMPLYING WITH REGULATION (EC) no. 640/2009 Cod. 191002201 Rev ev.a.a

More information

Lowara. Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series. 50 Hz

Lowara. Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series. 50 Hz Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733 SH Series 50 Hz SERIE SH OPERATING CHARACTERISTICS AT 50 Hz PRINT 05-2007 2 CONTENTS 5 Specifications......................................................................

More information

e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125

e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125 e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125 Vertical Multistage Electric Pumps equipped with high efficiency motors 50 Hz e-sv SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz WEB 07-2010 2 CONTENTS

More information

IN-LINE ELECTRIC PUMPS SINGLE AND TWIN. 50 Hz FC-FCT SERIES

IN-LINE ELECTRIC PUMPS SINGLE AND TWIN. 50 Hz FC-FCT SERIES IN-LINE ELECTRIC PUMPS SINGLE AND TWIN 50 Hz FC-FCT SERIES EDITION 03-2006 INDEX FC Series Specifications... 3 FC Series Construction Characteristics... 4 FCT Series Specifications... 5 FCT Series Construction

More information

50 Hz. Z612, Z616, Z622 Z631, Z646, Z660 Series 6 SUBMERSIBLE ELECTRIC PUMPS. ErP 2009/125/EC

50 Hz. Z612, Z616, Z622 Z631, Z646, Z660 Series 6 SUBMERSIBLE ELECTRIC PUMPS. ErP 2009/125/EC 5 Hz Z612, Z616, Z622 Z631, Z646, Z66 Series 6 SUBMERSIBLE ELECTRIC PUMPS ErP 29/125/EC Cod. 1915991 Rev. D Ed.9/217 CONTENTS Hydraulic performance range...4 Series Specifications...5 Table of Materials...7

More information

SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92

SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92 SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92 Vertical Multistage Electric Pumps equipped with high efficiency PLM motors 60 Hz SV SERIES HYDRAULIC PERFORMANCE RANGE AT 60 Hz WEB 04-2008 2 CONTENTS Specifications...5

More information

The e-nsc End Suction Pump Series

The e-nsc End Suction Pump Series NEW The e-nsc End Suction Pump Series Your go-to single-stage pump for heavy-duty use STANDARDIZED TO EN733, ISO 5199 AND DIRECTIVE 9/125/EC. POTABLE WATER APPROVED (ACS AND DM174). It s not your standard

More information

e-sv Series 1, 3, 5, 10, 15, 22 33, 46, 66, 92, 125 Lenntech 60 Hz Tel Fax.

e-sv Series 1, 3, 5, 10, 15, 22 33, 46, 66, 92, 125 Lenntech 60 Hz Tel Fax. 6 Hz e-sv Series 1, 3, 5, 1, 15, 22 33, 46, 66, 92, 125 HIGH EFFICIENCY VERTICAL MULTISTAGE ELECTRIC PUMPS EQUIPPED WITH IE2/IE3 MOTORS COMPLYING WITH REGULATION (EC) no. 64/29 Lenntech info@lenntech.com

More information

e-sh Series - ATEX Version ErP 2009/125/EC 50/60 Hz

e-sh Series - ATEX Version ErP 2009/125/EC 50/60 Hz 50/60 Hz e-sh Series - ATEX Version HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS ACCORDING TO DIRECTIVE 2014/34/EU MADE IN AISI 316 STAINLESS STEEL ErP 2009/125/EC Cod. 191003051 Rev. A Ed.11/2017 CONTENTS ATEX-approved

More information

SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92

SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92 SV Series SV 2, 4, 8, 16 SV 33, 46, 66, 92 Vertical Multistage Electric Pumps equipped with high efficiency PLM motors 50 Hz SV SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz WEB 06-2008 2 CONTENTS Specifications...5

More information

e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125

e-sv Series 1, 3, 5, 10, 15, 22, 33, 46, 66, 92, 125 e-sv Series 1, 3, 5, 1, 15, 22, 33, 46, 66, 92, 125 Vertical Multistage Electric Pumps equipped with high efficiency motors 5 Hz 2 e-sv SERIES HYDRAULIC PERFORMANCE RANGE AT 5 Hz 3 4 5 6 8 1 2 3 4 5 6

More information

60 Hz. SVI Series 2, 4, 8, 16, 33, 46, 66, 92 SUBMERSIBLE VERTICAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS

60 Hz. SVI Series 2, 4, 8, 16, 33, 46, 66, 92 SUBMERSIBLE VERTICAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS 6 Hz SVI Series 2, 4, 8, 16, 33, 46, 66, 92 SUBMERSIBLE VERTICAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS Cod. 1911291 Rev. C Ed.1/217 SVI SERIES HYDRAULIC PERFORMANCE RANGE AT 6 Hz 2 CONTENTS Specifications

More information

MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron

MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron Cast iron monobloc centrifugal electric pumps in compliance with EN 733. APPLICATIONS Moving clean water for civil, agricultural, industrial use, pressure boosting units, heating and air conditioning plants

More information

The e-nsc End Suction Pump Series

The e-nsc End Suction Pump Series NEW The e-nsc End Suction Pump Series Your go-to single-stage pump for heavy-duty use STANDARDIZED TO EN733, ISO 5199 AND DIRECTIVE 9/125/EC. POTABLE WATER APPROVED (ACS AND DM174). It s not your standard

More information

EH -EHsp SERIES 50 Hz

EH -EHsp SERIES 50 Hz PRODUCT CATALOG EH -EHsp SERIES 5 Hz HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS franklinwater.eu INDEX STAINLESS STEEL HORIZONTAL MULTISTAGE (EH) AND SELF-PRIMING (EHsp) PUMPS... 2 Family curves...3

More information

franklinwater.eu 50 HZ EH - EHsp SERIES HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS

franklinwater.eu 50 HZ EH - EHsp SERIES HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS franklinwater.eu 5 HZ EH - EHsp SERIES HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS INDEX Stainless Steel Horizontal Multistage (EH) and Self-Priming (EHsp) Pumps 2 Family curves 3 Pump identification

More information

Vertical multi-stage pumps

Vertical multi-stage pumps MK Vertical multi-stage pumps PERFORMANCE RANGE Flow rate up to 180 l/min (10.8 m³/h) Head up to 103 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +40 C Ambient

More information

GCEA-GCA GCEA(N)-GCA(N) Series made of AISI 316

GCEA-GCA GCEA(N)-GCA(N) Series made of AISI 316 GCEA-GCA GCEA(N)-GCA(N) Series made of AISI 316 Single and twin-impeller Centrifugal Electric Pumps 50 Hz GCEA-GCA - GCEA(N)-GCA(N) SERIES HYDRAULIC PERFORMANCE RANGE AT 50 Hz GCA GCEA PRINT 11-2006 2

More information

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial Vertical multistage centrifugal electric pumps available in various versions: cast iron (G), AISI 304 stainless steel (), AISI 316 stainless steel (L). APPLICATIONS Civil, industrial, agricultural and

More information

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial Vertical multistage centrifugal electric pumps available in various versions: cast iron (G), AISI 304 stainless steel (), AISI 316 stainless steel (L). APPLICATIONS Civil, industrial, agricultural and

More information

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps franklinwater.com 5 Hz VR SERIES Vertical Multi-Stage Pumps 5 HZ VR SERIES VERTICAL MULTI-STAGE PUMPS Features 2 Applications 2 Pump Specifications Counter-Flange Kits Motor Specifications 4 Ordering

More information

TPED /4-A-F-A-BQQE 3X400 50HZ

TPED /4-A-F-A-BQQE 3X400 50HZ GRUNDFOS DATA BOOKLET TPED 125-3/4-A-F-A-BQQE 3X4 5HZ Grundfos pump 98742617 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tped/98742617/tped-125-3-4-a-f-a-bqqe.html

More information

TP /2-A-F-A-BAQE 400D 50HZ

TP /2-A-F-A-BAQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 32-38/2-A-F-A-BAQE 4D 5HZ Grundfos Pump 968677 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/968677/tp-32-38-2-a-f-a-baqe.html

More information

TPED /4-S-A-F-A-BAQE 3X400 50HZ

TPED /4-S-A-F-A-BAQE 3X400 50HZ GRUNDFOS DATA BOOKLET TPED -9/-S-A-F-A-BAQE 3X 5HZ Grundfos Pump 99137 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpeds/99137/tped--9--s-a-f-a-baqe.html

More information

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 203 LPC4 32 205 LPC4 40 206 LPC4 50 211 LPC4 65 215 LPC4 80 219 LPC4 100 222 LPC4 125 225 LPC4 150 226 - CONSTRUCTIONS

More information

LPCD. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

LPCD. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 204 PERFORMANCE CURVE 50 205 PERFORMANCE CURVE 65 207 PERFORMANCE CURVE 80 208 PERFORMANCE

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE 201 SELECTION CHART 202 TYPE KEY 203 CURVE SPECIFICATIONS 204 PERFORMANCE CURVE 32-250/5.5 205 PERFORMANCE CURVE 32-250/7.5 205 PERFORMANCE CURVE 32-250/9.2

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 20 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 32-250/5.5 205 PERFORMANCE CURVE 32-250/7.5 205 PERFORMANCE CURVE

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page SPECIFICATIONS 0 PERFORMANCE RANGE and SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 MEI INDEX SPECIFICATIONS 5 PERFORMANCE CURVE 32 6 PERFORMANCE CURVE 32 7 PERFORMANCE

More information

MD - MMD. MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron. Japanese Technology since Commercial

MD - MMD. MONOBLOC CENTRIFUGAL ELECTRIC PUMP IN COMPLIANCE WITH EN 733 in cast iron. Japanese Technology since Commercial MD MMD Cast iron monobloc centrifugal pumps conforming to en 733. APPLICATIONS Handling of clean water for civil, agricultural, industrial uses and for pressurisation units, heating plants and air conditioning

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 3 ( 3-4-5-6 IMPELLERS ) 205 PERFORMANCE CURVE 3 ( 7-8-9 IMPELLERS

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 MEI INDEX SPECIFICATIONS 5 PERFORMANCE CURVE 32 6 PERFORMANCE CURVE 32 7 PERFORMANCE CURVE 320 8 PERFORMANCE

More information

TP /4-A-F-A-BUBE 400Y 50HZ

TP /4-A-F-A-BUBE 400Y 50HZ GRUNDFOS DATA BOOKLET TP 1-6/4-A-F-A-BUBE 4Y 5HZ Grundfos Pump 9642628 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9642628/tp-1-6-4-a-f-a-bube.html

More information

Etaline MN. In-line Pumps

Etaline MN. In-line Pumps Type Series Booklet 1146.51/05--EN Etaline In-line Pumps Automation products available: Hyamaster hyatronic Fields of Application F Heating systems F Air-conditioning systems F Cooling circuits F Service

More information

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017 Position Qty. Description 1 NB 1-31/29 A-F2-B-E-BAQE Phone: 4 84 61 Date: 13/3/217 Product No.: On request Non-self-priming, single-stage, centrifugal volute pump designed according to ISO 199 with dimensions

More information

NB /193 A-F2-A-BAQE

NB /193 A-F2-A-BAQE GRUNDFOS DATA BOOKLET NB100-200/193 A-F2-A-BAQE Grundfos Pump 98305367 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb000/98305367/nb-100-200-193-a-f2-a-e-baqe.html

More information

LPC. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

LPC. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 203 32 205 40 206 50 210 65 213 80 216 100 218 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 302 - DIMENSIONS

More information

EBARA LPC 4-POLIGA CENTRIFUGALA PUMPAR

EBARA LPC 4-POLIGA CENTRIFUGALA PUMPAR EBARA LPC 4-POLIGA CENTRIFUGALA PUMPAR CONTENTS - SPECIFICATIONS SELECTION CHART TYPE KEY AND CURVE SPECIFICATIONS LPC4 32 LPC4 40 LPC4 50 LPC4 65 LPC4 80 LPC4 100 LPC4 125 LPC4 150 - CONSTRUCTIONS SECTIONAL

More information

e-sv Series 1, 3, 5, 10, 15, 22 33, 46, 66, 92, 125 Lenntech 50/60 Hz Tel Fax.

e-sv Series 1, 3, 5, 10, 15, 22 33, 46, 66, 92, 125 Lenntech 50/60 Hz Tel Fax. 5/6 Hz e-sv Series 1, 3, 5, 1, 15, 22 33, 46, 66, 92, 125 SPECIAL VERSIONS Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 Cod. 191241 Rev ev.d Ed.6/212 CONTENTS INTRODUCTION

More information

HX, H2X and HCO Series Technical Guide. Monophasic and biphasic stainless steel centrifugal electropumps

HX, H2X and HCO Series Technical Guide. Monophasic and biphasic stainless steel centrifugal electropumps HX, H2X and HCO Series Technical uide Monophasic and biphasic stainless steel centrifugal electropumps HX, H2X and HCO Series Series, H2X y HCO t Index HX and H2X series application sectors... 4 HX series

More information

EBARA LPCD 4-POLIGA CENTRIFUGALA PUMPAR

EBARA LPCD 4-POLIGA CENTRIFUGALA PUMPAR EBARA LPCD 4-POLIGA CENTRIFUGALA PUMPAR CONTENTS - SPECIFICATIONS SELECTION CHART TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE LPCD4 40 PERFORMANCE CURVE LPCD4 50 PERFORMANCE CURVE LPCD4 65 PERFORMANCE

More information

TP /2-A-F-A-BQQE 400D 50HZ

TP /2-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 1-36/2-A-F-A-BQQE 4D 5HZ Grundfos pump 9619194 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9619194/tp-1-36-2-a-f-a-bqqe.html

More information

Centrifugal pumps. PERFORMANCE RANGE Flow rate up to 900 l/min (54 m³/h) Head up to 76 m

Centrifugal pumps. PERFORMANCE RANGE Flow rate up to 900 l/min (54 m³/h) Head up to 76 m CP Centrifugal pumps Clean water Civil use Agricultural use Industrial use PERFORMANCE RANGE Flow rate up to 9 l/min (5 m³/h) Head up to 76 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid

More information

TP /2-A-F-A-BUBE 1X230 50HZ

TP /2-A-F-A-BUBE 1X230 50HZ GRUNDFOS DATA BOOKLET TP 8-12/2-A-F-A-BUBE 1X23 5HZ Grundfos pump 9642448 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9642448/tp-8-12-2-a-f-a-bube.html

More information

TPE /4-A-F-A-BAQE 3X400 50HZ

TPE /4-A-F-A-BAQE 3X400 50HZ GRUNDFOS DATA BOOKLET TPE 1-11/-A-F-A-BAQE 3X 5HZ Grundfos Pump 99113 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpe/99113/tpe-1-11--a-f-a-baqe.html

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304 CONTENTS 1 Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES 32-250/7.56 203 PERFORMANCE CURVES 32-250/9.26 203 PERFORMANCE CURVES

More information

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16) Data sheet: Wilo-Multivert MVI 8 (~ V, EPDM, PN ) Pump curves 89 8 Wilo-Multivert-MVI 8-89 Hz Power Fluid temperature T -...+ C NPSH [m] H[m] 8 8 8 8 88 8 8 8 8 8 8 8 8 η p NPSH 8 8 [l/s] 89 η p [%] Max.

More information

ILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2.

ILN, ILNC. In Line vertical pumps. ILN single suction ILN double suction ILNC. 1. Fields of Application. 3. Design. 4. Designation. 2. Type series booklet CTI-2600/04 [04-2017] ILN, ILNC In Line vertical pumps ILN single suction ILN double suction ILNC sizes 65/ to 250/... sizes 300/ all sizes 1. Fields of Application Suitable for a wide

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 PERFORMANCE CURVE 32-125 5 PERFORMANCE CURVE 32-6 PERFORMANCE CURVE 32-0 7 PERFORMANCE CURVE 40-125 8 PERFORMANCE

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 32-250/5.5 205 PERFORMANCE CURVE 32-250/7.5 205 PERFORMANCE CURVE

More information

NB /438 A-F1-A-GQQE

NB /438 A-F1-A-GQQE GRUNDFOS DATA BOOKLET NB15-4/438 A-F1-A-GQQE Grundfos pump 983626 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb/983626/nb-15-4-438-a-f1-a-e-gqqe.html

More information

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS HZ Evak Pump Technology Corp. No., Zhongshan Rd., Qingshui Township, Taichung County, Taiwan. Tel : +-- Fax: +--9 www.evak-pumps.com Vol. PIAV- A-Series Index Multistage

More information

NK40-160/172A1F2AE-SBAQE

NK40-160/172A1F2AE-SBAQE GRUNDFOS DATA BOOKLET NK4-16/172A1F2AE-SBAQE Grundfos pump 9782923 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nkbasis/9782923/nk-4-16-172-a1-f-a-e-baqe.html

More information

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

Submersible Borehole Pump. UPAchrom. 4, UPAchrom 100 CC + DN 100. Type Series Booklet Submersible Borehole Pump UPAchrom 4", UPAchrom 1 CC + DN 1 Type Series Booklet Legal information/copyright Type Series Booklet UPAchrom All rights reserved. The contents provided herein must neither be

More information

NBE50-250/205 A-F2-A-BAQE

NBE50-250/205 A-F2-A-BAQE GRUNDFOS DATA BOOKLET NBE5-25/25 A-F2-A-BAQE Grundfos pump 9518635 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nbe/9518635/nbe-5-25-25-a-f2-a-e-baqe.html

More information

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 65-250 204 PERFORMANCE CURVE 80-160 205 PERFORMANCE CURVE 80-200 206 PERFORMANCE CURVE 80-250

More information

TPE N-A-F-A-GQQE

TPE N-A-F-A-GQQE GRUNDFOS DATA BOOKLET TPE2 1-15-N-A-F-A-GQQE Grundfos Pump 98416973 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpe/98416973/tpe2-1-15-n-a-f-a-gqqe.html

More information

MMD. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

MMD. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 65-250 204 PERFORMANCE CURVE 80-160 205 PERFORMANCE CURVE 80-200 206 PERFORMANCE CURVE 80-250

More information

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16) Data sheet: Wilo-Multivert MVI 5 (3~4 V, EPDM, PN 16) Pump curves 4 Wilo-Multivert-MVI - 5 Hz Power Fluid temperature T -15...+1 C 18 17 Max. ambient temperature T 4 C P [kw] NPSH [m] H[m] 14 16 14 1 1

More information

N, N4. End-Suction Centrifugal Pumps standardized EN 733

N, N4. End-Suction Centrifugal Pumps standardized EN 733 , Construction Single-stage end-suction centrifugal pumps, with bearing bracket. ominal duty points and main dimensions in accordance with E 7. Back Pull-Out construction, for simple and quick dismantling

More information

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design Data sheet Page: 1 / 5 Operating data Requested flow rate Operating data determined for maximum inlet pressure Requested developed head 15.00 m Pumped medium Ambient air temperature 20.0 C Fluid temperature

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS 300 SECTIONAL VIEW

More information

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16)

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16) Data sheet: Wilo-Multivert MVI (1~3 V, EPDM, PN 16) Pump curves Wilo-Multivert-MVI - 5 Hz Power Fluid temperature T -15...+1 C 18 16 Max. ambient temperature T C 1 1 Maximum operating pressure p max 16

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 FITTINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 FITTINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART TABLE 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 25/08 204 PERFORMANCE CURVE 25/15 205 PERFORMANCE CURVE 25/25 206

More information

TPE N-A-F-A-GQQE

TPE N-A-F-A-GQQE GRUNDFOS DATA BOOKLET TPE2 65-15-N-A-F-A-GQQE Grundfos pump 98438388 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpe/98438388/tpe2-65-15-n-a-f-a-gqqe.html

More information

COMMISSION REGULATION (EC)

COMMISSION REGULATION (EC) L 191/26 Official Journal of the European Union 23.7.2009 COMMISSION REGULATION (EC) No 640/2009 of 22 July 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard

More information

NBE40-125/139 AS-F2-A-BAQE

NBE40-125/139 AS-F2-A-BAQE GRUNDFOS DATA BOOKLET NBE-125/139 AS-F2-A-BAQE Grundfos pump 999983 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nbe/999983/nbe--125-139-as-f2-a-e-baqe.html

More information

MMD 4 Poles. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

MMD 4 Poles. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE MMD4 32-250 205 PERFORMANCE CURVE MMD4 40-250 206 PERFORMANCE CURVE MMD4 50-250 207 PERFORMANCE

More information

VERTICAL MULTISTAGE PUMPS HIL AND HILFLEX SEE OUR FLEXDRIVE LEAFLET FOR DRIVE DETAILS. reliable efficient quality. Pumping Technology

VERTICAL MULTISTAGE PUMPS HIL AND HILFLEX SEE OUR FLEXDRIVE LEAFLET FOR DRIVE DETAILS. reliable efficient quality. Pumping Technology TM VERTICAL MULTISTAGE PUMPS HIL AND HILFLEX SEE OUR FLEXDRIVE LEAFLET FOR DRIVE DETAILS reliable efficient quality HIL Vertical Multistage Pumps Introduction Smedegaards' range of HIL vertical multistage

More information

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz GRUNDFOS DATA BOOKLET CR15-1 A-F-A-E-HQQE 11kW 3x4D 5Hz Grundfos Pump 965191 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/965191/cr-15-1-a-f-a-e-hqqe.html

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

PVM/PVMI/PVMX VERTICAL MULTISTAGE CENTRIFUGAL PUMPS

PVM/PVMI/PVMX VERTICAL MULTISTAGE CENTRIFUGAL PUMPS PVM/PVMI/PVMX High hydraulic efficiency, Motor designed according to EN regulations IE3 MOTOR PVM, PVMI and PVMX are non selfpriming vertical multi-stage pumps, with Victaulic or flanged fittings with

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR64-3-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96123531 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123531/cr-64-3-2-a-f-a-e-hqqe.html

More information

CP Centrifugal pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS PATENTS - TRADE MARKS - MODELS CONSTRUCTION AND SAFETY STANDARDS

CP Centrifugal pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS PATENTS - TRADE MARKS - MODELS CONSTRUCTION AND SAFETY STANDARDS CP Centrifugal pumps PERFORMANCE RANGE Flow rate up to 900 l/min (54 m³/h) Head up to 74 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning In-Line centrifugal electric pumps with stainless steel hydraulic parts AISI 304. APPLICATIONS Civil/industrial heating plants Systems for moving domestic hot water Cooling and air conditioning plants

More information

NK /310A2F1AE-SBAQE

NK /310A2F1AE-SBAQE GRUNDFOS DATA BOOKLET NK15-315/31A2F1AE-SBAQE Grundfos Pump 98318632 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nkbasis/98318632/nk-15-315-31-a2-f-a-e-baqe.html

More information

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS HZ Evak Pump Technology Corp. No., Zhongshan Rd., Qingshui Township, Taichung County, Taiwan. Tel : +-- Fax: +--9 www.evak-pumps.com Vol. PIAV- A-Series Index Pump

More information

TP /2-A-F-A-BQQE 400D 50HZ

TP /2-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 65-46/2-A-F-A-BQQE 4D 5HZ Grundfos Pump 9687526 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9687526/tp-65-46-2-a-f-a-bqqe.html

More information

A Series. 60 Hz. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series. 60 Hz. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001 A - Series A Series ISO-9 AVC/AVI/AVS Hz Evak Pump Technology Corp. No. 55, Zhongshan Rd., Qingshui Dist., Taichung City, Taiwan. Tel : +--55 Fax: +--5559 www.evak-pumps.com Vol. PIAV- A-Series Index Pump

More information

CDX CENTRIFUGAL PUMPS EPA

CDX CENTRIFUGAL PUMPS EPA 4 CONTENTS V4 - SPECIFICATIONS Page Features & Applications 00 Typical Exploded View 0 Pump & Motor Specifications 02 Selection Chart / Type key 03 - PERFORMANCE CURVES Performance Curve Specifications

More information

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR15-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651893 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651893/cr-15-2-a-f-a-e-hqqe.html

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL AND BEARINGS 302 MECHANICAL SEAL 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL AND BEARINGS 302 MECHANICAL SEAL 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE A (UP TO 0.6 KW) 204 PERFORMANCE CURVE A (FROM 0.75 KW UP TO 1.1 KW)

More information

TP /4-A-F-A-BQQE 400Y 50HZ

TP /4-A-F-A-BQQE 400Y 50HZ GRUNDFOS DATA BOOKLET TP 4-1/4-A-F-A-BQQE 4Y 5HZ Grundfos Pump 9686883 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9686883/tp-4-1-4-a-f-a-bqqe.html

More information

Hydro MPC-E 3 CRIE5-9 U1 A-A-A-GH GNL

Hydro MPC-E 3 CRIE5-9 U1 A-A-A-GH GNL GRUNDFOS DATA BOOKLET Hydro MPC-E 3 CRIE5-9 U1 A-A-A-GH GNL Grundfos Pump 99324971 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tpeds2/99324971/tpe3-d-1-15-s-ai-f-a-bqqe.html

More information

NB /263 AS-F2-A-BAQE

NB /263 AS-F2-A-BAQE GRUNDFOS DATA BOOKLET NB125-25/263 AS-F2-A-BAQE Grundfos pump 9832195 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb/9832195/nb-125-25-263-as-f2-a-e-baqe.html

More information

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ GRUNDFOS DATA BOOKLET CR5-26 A-FGJ-A-E-HQQE 3x4D 5HZ Grundfos Pump 96513391 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96513391/cr-5-26-a-fgj-a-e-hqqe.html

More information

CMA-B-C-D. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

CMA-B-C-D. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE 201 SELECTION CHART 202 TYPE KEY 203 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE CMA 204 PERFORMANCE CURVE CMB 205 PERFORMANCE CURVE CMC 206 PERFORMANCE

More information

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CR5-6 A-FGJ-A-E-HQQE 3x23/4 5HZ Grundfos Pump 9651741 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651741/cr-5-6-a-fgj-a-e-hqqe.html

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 PERFORMANCE CHART A (up to 0.6 kw) 203 PERFORMANCE CHART A (from 0.75 kw up to 1.1 kw) 204 PERFORMANCE CHART A (1.3 kw) 205 PERFORMANCE

More information

DUAL IMPELLER CENTRIFUGAL ELECTRIC PUMPS in AISI 304 and AISI 316

DUAL IMPELLER CENTRIFUGAL ELECTRIC PUMPS in AISI 304 and AISI 316 Dual impeller centrifugal electric pumps with hydraulic parts in AISI 304 and AISI 316. APPLICATIONS Domestic pressure boosting Small-scale garden irrigation Washing Treating water Cooling towers Pumping

More information