STEEL ROOF & FLOOR DECK

Size: px
Start display at page:

Download "STEEL ROOF & FLOOR DECK"

Transcription

1 VULCRAFT STEEL ROOF & FLOOR DECK AUGUST 08 Better Partners. Better Products. Better Outcomes.

2 PLANT INFORMATION Vulcraft Alabama 705 Gault Ave. N Fort Payne, AL Vulcraft Indiana 660 County Road 60 St. Joe, IN Vulcraft Nebraska 60 West Omaha Ave. Norfolk, NE Vulcraft South Carolina 50 West Darlington Street Florence, SC Vulcraft Texas 75 County Road 45 Grapeland, TX Vulcraft Utah (Joist Only) 875 West Highway South Brigham City, UT Vulcraft of New York 6 Main Street Chemung, NY Nucor Corporation. All Rights Reserved AUG 08

3 General Product Information... 4 Finishes... 4 Product Offer... 5 Dovetail... 6 Cellular & Acoustic... 7 LEED Information... 9 PunchLok II System... 0 ROOF DECK.5B /.5BI /.5BA /.5BIA... N / NI / NA / NIA....5F A D D E... 8 Fire Resistance Ratings with Roof... 9 Roof Web Crippling Data... 0 Roof Accessories... FM Global... NON-COMPOSITE FLOOR DECK 0.6C / 0.6CSV C /.0CSV... 6.C /.CSV C... 0 C... C... 4 TABLE OF CONTENTS COMPOSITE FLOOR DECK.5VL /.5VLI VLR VLI VLI... 5 Fire Resistance Ratings with Composite VULCRAFT reserves the right to change the design or details of its products without notice. The information in this catalog is presented for general information only and is not to be used or relied upon for any application without complete review of the proposed application and without a complete review by a licensed professional architect, engineer, designer or other qualified professional. VULCRAFT assumes no liability whatsoever for the accuracy or completeness of the information contained herein. VULCRAFT makes no representation or warranty of any kind, either express or implied, respecting any information contained in this catalog including, but not limited to, the accuracy, completeness or suitability of such information for any particular purpose or use. In addition, VULCRAFT expressly disclaims any liability for incidental, special, consequential or punitive damages including, but not limited to, loss of profits or loss of use arising out of this catalog or its use. VULCRAFT S liability, warranties and other obligations with respect to its products are set forth in the Terms and Conditions of Sale provided to Buyer in connection with the provision of such products. As used herein, references to VULCRAFT include its parents, affiliates and subsidiaries. Non-Composite Slab Design... 6 Venting... 6 Reinforced Concrete Load Tables... 7 Fire Resistance Ratings with Non-Composite (Form)40 Non-Composite & Composite Construction Loading4 Web Crippling Example... 4 Non-Composite & Composite Web Crippling Data... 4 Non-Composite & Composite Pour Stop Table Non-Composite & Composite Details DIAPHRAGM Diaphragm Design Typical Fastener Layout C,.0C,.C VL,.5VLI, C, VLI, C, VLI The PunchLok II Tool and the method of using it are the subject of U.S. Patent No. 6,,9, U.S. Patent No. 6,97,469 and/ or U.S. Patent No. 8,667,656. VULCRAFT and NUCOR are registered trademarks of Nucor Corporation. VERCO and PUNCHLOK are registered trademarks of Verco ing, Inc. BETTER PARTNERS. BETTER PRODUCTS. BETTER OUTCOMES.TM, PLBTM, PLNTM, VLTM, VLITM and VLRTM are trademarks of Nucor Corporation or its affiliates. All other names may be trademarks of their respective owners. All rights reserved. AUG 08

4 VULCRAFT STEEL ROOF & FLOOR DECK VULCRAFT, a leader in the steel joist and joist girder industry offers a complete range of steel decking at six strategically located deck manufacturing facilities. The deck is accurately roll formed in varying configurations on the most modern high-speed roll forming equipment available. Steel roof and floor decks have long been recognized for their economy because of their light weight and high strengthto-weight ratio. They provide a durable and attractive roof or floor system for fast all-weather construction. Steel decks also provide excellent lateral diaphragm action thus reducing the necessity for structural bracing and their incombustible nature assures architects, engineers and owners of excellent fire ratings. ROOF DECK Vulcraft roof decks are designed in accordance with the ANSI / Steel Institute RD Standard for Steel Roof in conformance with the 05 IBC. SDI RD Standard available at: Roof Profiles:.5B,.5BI,.5PLB,.5F,.5A, N, NI, PLN,.0E,.0D,.5D Acoustical Roof Profiles:.5BA,.5BIA, NA, NIA,.0DA,.5DA NON-COMPOSITE FLOOR DECK Vulcraft non-composite (form) decks are designed in accordance with the ANSI / Steel Institute NC Standard for Non-Composite Steel Floor in conformance with the 05 IBC. SDI NC Standard available at: Non-Composite Floor Profiles: 0.6C, 0.6CSV,.0C,.0CSV,.C,.CSV,.5C, C, C COMPOSITE FLOOR DECK Vulcraft composite floor decks are designed in accordance with the ANSI / Steel Institute C-0 Standard for Composite Steel Floor -Slabs in conformance with the 05 IBC. SDI C-0 Standard available at: Composite Floor Profiles:.5VL,.5VLI,.5VLR, VLI, VLI DIAPHRAGM The Diaphragm Shear Strength and Stiffness tables in this catalog are based on the Third Edition of the Diaphragm Manual (published by the Steel Institute). MATERIAL Galvanized fluted decks are formed from either ASTM A65 or A06 steel. Painted/painted or mill finished (black) uncoated fluted roof decks are formed from either ASTM A008 or A09 steel. Cellular deck sections are fabricated from galvanized steel conforming to ASTM A65 or A06. FINISHES Vulcraft offers a selection of finishes: primer painted over cold-rolled or galvanized, galvanized, or black (uncoated). Primer painted: Prior to applying a baked-on acrylic medium gray or white primer, the cold-rolled or galvanized sheet is chemically cleaned and pre-treated. Galvanized: Galvanized decks are supplied from mill coated sheets and are offered in two zinc coated finishes. Coating designation G60 is the standard galvanized material of the deck industry. Coating designation G90 is a heavier, zinc coating often specified for exposed exterior applications or other project specific requirements. Other ASTM A65 galvanized coatings may be available on special request contact your Vulcraft representative regarding availability. 4 AUG 08

5 COMPOSITE FLOOR DECK NON-COMPOSITE FLOOR DECK DOVETAIL DECK ROOF DECK PRODUCT OFFER INFORMATION Approximate Dimensions in inches Indiana Nebraska South Carolina Texas Alabama / New York Type Gage C P T B C P T B C P T B C P T B C P T B.5B /.5BI /.5BA /.5BIA N / NI / NA / NIA.5F.5A.0E.0D /.0DA.5D /.5DA 0.6C / 0.6CSV.0C /.0CSV.C /.CSV.5C C C.5VL /.5VLI.5VLR VLI VLI NA NA NA NA NA NA NA NA NA NA NA NA NA 0 0 NA NA NA NA NA NA NA AUG 08 5

6 CEILING DoveTail If you need the best, you need Vulcraft s DoveTail steel roof deck. The innovative, high-quality decking system boasts a clean, sleek design with distinct shadow lines to provide texture to the ceiling surface. The DoveTail acoustic steel deck uses pioneering sound-reducing technology to deliver a calm, quiet interior environment all while reducing overall design costs. Vulcraft s DoveTail deck delivers. Economical -inch-deep and long spanning.5-inch-deep products Excellent acoustic performance with Noise Reduction Coefficient (NRC) of 0.95 to.5 Naturally hides unsightly roof system fasteners with the re-entrant shape of DoveTail Factory painted options Proven performance listed with UL, FM and IAPMO-UES For complete performance information, contact Vulcraft to get your Vulcraft DoveTail Roof Catalog or download directly at The Vulcraft Structural DoveTail Ceiling/ is available in -inch-deep and.5-inch-deep profiles. 6 AUG 08

7 Acoustical Cellular Cellular deck is used for flat acoustical ceilings, canopies, long spans, and heavy forms. Vulcraft cellular units are approved by U.L for use as electrical raceways. Contact your Vulcraft representative for more information. CEILING NOISE REDUCTION COEFFICIENTS OF ACOUSTICAL CELLULAR DECK Type Cellular Roof Above Material Fiberglass Insulation Absorption Coefficients 5 Hz 50 Hz 500 Hz 000 Hz 000 Hz 4000 Hz SSA NRC RAL Test No..5BPA Poly-Iso Plain ( pcf) A5-4 NPA Poly-Iso Plain ( pcf) A5-4 Cellular Composite Floor.5VLPA Concrete Plain ( pcf) A5-8 VLPA Concrete Plain ( pcf) A5-0 VLPA Concrete Plain ( pcf) A5- Acoustical Roof Acoustical decks can provide sound attenuation within buildings where the decks are exposed to the interior. Acoustical deck is particularly suitable in structures such as auditoriums, schools, gymnasiums and theaters where sound control is desirable. NOISE REDUCTION COEFFICIENTS OF ACOUSTICAL DECK Type Roof.5BA or.5bia NA or NIA DoveTail.0DA.5DA Above Material Fiberglass Insulation Absorption Coefficients 5 Hz 50 Hz 500 Hz 000 Hz 000 Hz 4000 Hz SSA NRC RAL Test No. Poly-Iso Plain (0.75 pcf) A5-5 Fiberglass Plain (0.75 pcf) A5-6 Poly-Iso Plain (0.75 pcf) A5-0 Fiberglass Plain (0.75 pcf) A5-8 Poly-Iso Plain ( pcf) A4-70 Fiberglass Plain ( pcf) A4-69 Poly-Iso Plain ( pcf) A4-86 Fiberglass Plain ( pcf) A4-87 Acoustical Notes: ) For acoustical test reports please contact your Vulcraft representitive. ) Contact your Vulcraft representative for acoustical performance data of alternate assemblies. AUG 08 7

8 CELLULAR DECK PRODUCTS CEILING CELLULAR ROOF DECK Vulcraft produces the following acoustical and non-acoustical cellular roof decks: Cellular Roof Profiles:.5BP and NP Cellular Acoustical Roof Profiles:.5BPA and NPA CELLULAR COMPOSITE FLOOR DECK Vulcraft produces the following acoustical and non-acoustical cellular composite floor decks: Cellular Composite Floor Profiles:.5VLP, VLP and VLP Cellular Acoustical Composite Floor Profiles:.5VLPA, VLPA and VLPA Cellular decks are available in the following gage combinations (hat / pan): 0/0, 0/8, 8/0, 8/8, 8/6, 6/8, and 6/6. CELLULAR DECK DESIGN Design of cellular deck may be conservatively based on the guidelines outlined below. Please contact your Vulcraft representative if more detailed information is required. CELLULAR ROOF DECK Vertical Load Design: Vertical load design of cellular deck may be based on the properties of fluted deck of the same gage and profile as the fluted top section, with or without acoustical perforations in the flat bottom section of the cellular deck. Diaphragm Design: Diaphragm shear strength and flexibility factors for B and N fluted decks are applicable to cellular sections with a fluted top section of the same profile but with the gage of the flat bottom sheet, with or without acoustical perforations in the flat bottom section of the cellular deck. See Roof Legacy Diaphragm Tables, available at catalogs for B and N roof deck diaphragm tables. CELLULAR COMPOSITE FLOOR DECK Unshored Clear Spans: Determination of maximum unshored clear spans of cellular deck may be based on the properties of fluted deck of the same gage and profile as the fluted top section, with or without acoustical perforations in the flat bottom section of the cellular deck. Superimposed Live Load: Superimposed live loads for Vulcraft composite decks for a given concrete type and thickness may be applied to composite cellular sections with a fluted top section of the same profile and gage, with or without acoustical perforations in the flat bottom section of the cellular deck. Diaphragm Design: Diaphragm shear strength and flexibility factors shown on pages 68 to 69 for fluted composite decks are applicable to cellular sections with a fluted top section of the same profile but with the gage of the flat bottom sheet, with or without acoustical perforations in the flat bottom section of the cellular deck. 8 AUG 08

9 LEED Vulcraft Group Vulcraft - Florence, SC; Norfolk, NE; Brigham City, UT; Grapeland, TX; St. Joe, IN; Fort Payne, AL; Chemung, NY; Nisku, AB; Ancaster, ON Verco ing, Inc. Phoenix, AZ; Fontana, CA; Antioch, CA Joists/Structural Products - The bar steel for Vulcraft joists is typically obtained from one of the ten (0) Nucor bar mills. That would mean that the average recycled content percentage for the Vulcraft group is 94.6%. The post- and pre-consumer recycled content have been calculated to be 8.0% and.7% respectively. Specific project information is available from facility representatives. Steel for decking produced by Vulcraft facilities is typically obtained from one of the seven (7) Nucor sheet mills. That would mean that the Vulcraft deck products contain 60.6% recycled steel. The post- and pre-consumer recycled content were calculated to be.7% and 8.9% respectively. Verco ing, Inc. may obtain steel from sources outside of Nucor that may contain lower amounts of recycled content. Specific product information regarding Verco ing, Inc., and individual Vulcraft locations is available from facility representatives. LEED v4 Information Nucor can provide a variety of documentation to help projects satisfy LEED v4 credit requirements. Nucor publishes a Corporate Sustainability Report bi-annually which can be found here - Additional LEED and/or other environmental information regarding specific Nucor Corporation products for a customer s specific order is available from facility representatives or the corporate office. A current contact list can be found here - Additional industry information is available on-line through the Steel Recycling Institute at We continue to develop product-specific Environmental Product Declarations and Health Product Declarations for a variety of product groups. Nucor has participated in multiple industry-wide Environmental Product Declarations which can be used for Nucor products. Additionally Nucor will work individually with any customer requiring product life cycle inventory data or other environmental footprint information. Regional Materials LEED 009 Credit 5; LEED v4 Local Sourcing Nucor tracks the origin of scrap shipments to our mills. Nucor can approximate the amount of scrap recovered from any project site region. Nucor owns steel and steel products manufacturing facilities throughout the US that are often within 500 miles of the project site. Please refer to the LEED Contact List ( then click on LEED Contact ), and contact the specific Nucor representative at the facility directly. AUG 08 9

10 PunchLok II System PUNCKLOK II Vulcraft PunchLok II roofing and decking system is an easy, low-cost way to install steel roof decks. The PunchLok II System not only has the highest diaphragm shear, but it also provides the building s owner with incredible value by minimizing steel deck attachments and reducing steel deck gage. Vulcraft s PunchLok II System gets the job done right. Works with all common steel deck profiles:.5plb,.0pln,.5plvi.0plvli, &.0PLVLI Pneumatic PunchLok II tool creates the VSC crimp connection The PunchLok II system provides a positive, permanent VSC sidelap attachment for steel deck The VSC seam attachments are easily verified through visual inspection Punch once... PunchLok II System Brings Value to Your Project Gage Weld to Supports Low Shear < 500 plf...and forget about it. Sidelaps Shear PunchLok II System Value # per Span Type (plf) B 6/7 6 #0 screws 495 Same gage of steel deck, Fewer sidelap connections, PLB 6/4 VSC 479 Eliminates,000 welds per 00,000 sf Gage Weld to Supports 500 plf < Modest Shear < 000 plf Sidelaps Shear PunchLok II System Value # per Span Type (plf) B 8 6/7 7 #0 screws 84 ga PLB saves 5 tons of steel per 00,000 sf, Fewer sidelap connections, PLB 6/4 6 VSC 856 Eliminates,000 welds per 00,000 sf Gage Weld to Supports High Shear > 000 plf Sidelaps Shear PunchLok II System Value # per Span Type (plf) B 8 6/7 0 Weld 4 Comparable number of sidelap connections, 0 ga PLB saves 8 tons of steel per 00,000 sf PLB 0 6/4 7 VSC 59 Eliminates 66,000 welds per 00,000 sf #0 Side Lap Screw VSC PunchLok II System Support Welds 6/7 B Steel Welds For complete performance information, contact Vulcraft to get your Vulcraft PunchLok II Roof Catalog or download directly at 6/4 PLB Steel Welds 0 AUG 08

11 PUNCKLOKII AUG 08

12 .5B /.5BI /.5BA /.5BIA ROOF DECK Maximum Sheet Length 4-0 Extra charge for lengths under 6-0 ICC ESR-7 FM Global Approved DIMENSIONS ROOF SECTION PROPERTIES Type Design Thickness (in.) Weight (psf) Section Properties I p S p I n S n (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) Interlocking Sidelap *Sidelaps not drawn to show actual detail. V a (lbs/ft) B B B B B B F y (ksi) Nested Sidelap VERTICAL LOADS FOR TYPE.5B No. of Spans Type Max. SDI Const. Span Allowable Total Load (psf) / Load Causing Deflection of L/40 or inch (psf) Span (ft-in.) ctr to ctr of supports B4 4'-8 5 / / 4 80 / 68 / 6 59 / 0 5 / 7 45 / 4 40 / 5 / 0 / 8 9 / 7 B 5'-7 98 / 8 8 / 6 68 / / 7 50 / 0 44 / 4 8 / 0 4 / 7 0 / 4 7 / 5 / 0 B0 6'-5 / 05 0 / / 6 7 / 48 6 / 8 55 / 48 / 6 4 / 8 / 8 4 / 5 / B9 7'- 46 / 9 / 97 0 / / / / 8 57 / 5 / 6 45 / 40 / 9 6 / 6 B8 7'-8 68 / 5 8 / 4 6 / / / / / 7 58 / 5 / 6 46 / 4 / 9 B6 8'-8 5 / / / 7 / 89 0 / 7 96 / / / / 4 60 / 9 54 / 4 B4 5'-0 4 / 5 0 / 5 86 / / / / / 7 4 / 9 / 6 5 / / 9 B 6'- 00 / 8 / / 4 59 / 97 5 / / 6 9 / 5 5 / 4 / 7 8 / 5 / 7 B0 7'-9 8 / / 0 89 / / 66 / / 79 5 / / / 46 6 / 9 / B9 8'-5 50 / 0 4 / / / / 6 67 / / 78 5 / / 55 4 / 47 8 / 40 B8 9'- 69 / / 77 8 / 0 / / 4 76 / / / 75 5 / 6 48 / 54 4 / 46 B6 0'- / / / 7 7 / 4 0 / 7 95 / / 5 74 / / 8 60 / / 59 B4 5'-0 54 / 0 8 / / 69 9 / / / 5 6 / 9 54 / 4 48 / 4 / 7 9 / 5 B 6'- 4 / 67 0 / 6 87 / / / 6 56 / / 4 4 / 4 9 / 9 5 / 4 / B0 7'-9 59 / 09 / 57 / 95 / 95 8 / 76 7 / 6 6 / 5 56 / 4 50 / 6 45 / 40 / 6 B9 8'-5 86 / / 88 0 / 45 / 4 96 / 9 84 / / 6 65 / 5 58 / 4 5 / 7 47 / B8 9'- 0 / / 7 47 / 67 6 / 08 / / 86 8 / 7 74 / / / 4 54 / 6 B6 0'- 64 / 69 9 / / 4 58 / 68 6 / 5 9 / / 90 9 / 75 8 / 6 74 / / 46 Notes: ) Minimum exterior bearing length required is.50 inches. Minimum interior bearing length is.00 inches. If these minimum lengths are not provided, web crippling must be checked. ) FM Global approved spans available on page. AUG 08

13 N / NI / NA / NIA ROOF DECK Maximum Sheet Length 4-0 Extra charge for lengths under 6-0 ICC ESR-7 FM Global Approved DIMENSIONS SECTION PROPERTIES Type Design Thickness (in.) Weight (psf) Section Properties I p S p I n S n (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) Interlocking Sidelap *Sidelaps not drawn to show actual detail. V a (lbs/ft) N N N N N F y (ksi) Nested Sidelap ROOF VERTICAL LOADS FOR TYPE N No. of Spans Type Max. SDI Const. Span Allowable Total Load (psf) / Load Causing Deflection of L/40 or inch (psf) Span (ft-in.) ctr to ctr of supports N '-7 50 / 4 46 / 7 4 / 8 / 8 5 / 5 / 0 / 0 8 / 8 6 / 6 4 / 4 / N0 '- 66 / / / 4 50 / 7 46 / 4 / 8 9 / 5 6 / 4 / 0 / 8 9 / 6 N9 4'-7 79 / 69 7 / / 5 59 / / / 5 47 / 4 / 8 40 / 5 7 / 5 / 0 N8 5'- 9 / 8 8 / / 6 69 / 5 6 / / 4 54 / 7 50 / 46 / 0 4 / 7 40 / 4 N6 8'-6 8 / 0 07 / / 8 89 / 7 8 / / / / / / 6 5 / N '-8 56 / 5 / / 9 4 / 80 9 / 7 6 / 6 4 / 55 / 50 9 / 44 7 / 40 5 / 6 N0 5'-6 7 / 5 65 / 60 / 4 55 / / / 78 4 / / 6 7 / 55 4 / 50 / 45 N9 6'- 86 / 8 78 / 57 7 / 7 65 / 0 60 / / 9 5 / 8 47 / / 66 4 / 60 8 / 54 N8 8'- 98 / 89 / 8 8 / / 9 68 / 6 / / / / / / 6 N6 0'-4 / 76 / 8 0 / 07 9 / 8 86 / / 4 7 / 5 68 / 6 / / / 8 N '-8 69 / / 8 58 / 7 5 / 6 49 / / 49 4 / 4 9 / 9 6 / 5 4 / / 8 N0 5'-6 90 / 9 8 / 0 74 / / 78 6 / / 6 5 / / / 4 4 / 9 40 / 5 N9 6'- 07 / 4 97 / 89 / 07 8 / / 8 69 / 7 64 / / / 5 5 / / 4 N8 8'- / 65 / 4 0 / 4 9 / / / 84 7 / / 67 6 / / / 49 N6 0'-4 54 / 6 9 / 86 7 / 6 6 / 4 07 / 5 99 / 9 / / / / 7 69 / 64 Notes: ) Minimum exterior bearing length required is.50 inches. Minimum interior bearing length is.00 inches. If these minimum lengths are not provided, web crippling must be checked. ) FM Global approved spans available on page. AUG 08

14 .5F ROOF DECK Maximum Sheet Length 4-0 Extra charge for lengths under 6-0 ICC ESR-7 FM Global Approved DIMENSIONS ROOF SECTION PROPERTIES Type Design Thickness (in.) Weight (psf) Section Properties I p S p I n S n (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) V a (lbs/ft) F F F F F y (ksi) VERTICAL LOADS FOR TYPE.5F No. of Spans Type Max. SDI Const. Span Allowable Total Load (psf) / Load Causing Deflection of L/40 or inch (psf) Span (ft-in.) ctr to ctr of supports F 4-9 / 6 7 / 8 59 / / 45 4 / 4 5 / 7 0 / 6 / 8 / 4 0 / 8 / 0 F / / 04 7 / 76 6 / 57 5 / 44 4 / 5 7 / 8 / 9 / 9 5 / 5 / F / 8 08 / 7 87 / 9 7 / 70 6 / 54 5 / 4 45 / 4 9 / 8 4 / 0 / 9 7 / 6 F / 4 / / 08 8 / 8 70 / 6 59 / 49 5 / 9 44 / 9 / 6 5 / / 9 F 5-99 / / 0 6 / 5 5 / 5 44 / 88 8 / 70 / 56 8 / 45 5 / 7 / 0 / 6 F0 6-6 / 7 96 / 6 78 / 9 64 / 4 54 / 0 46 / / 70 5 / 57 0 / 47 7 / 9 4 / F / 444 / 90 / 7 75 / 7 6 / 5 / / 8 40 / 67 5 / 56 / 46 8 / 9 F / 5 6 / 59 0 / 6 85 / 96 7 / 5 6 / 9 5 / / / 64 5 / 5 / 45 F 5 - / 4 97 / / 0 65 / / / 55 4 / 44 5 / 5 / 9 8 / 4 5 / F / 9 9 / / / 67 / / / 54 4 / 44 8 / 6 4 / 0 0 / 6 F / 48 9 / 44 / 78 9 / 4 78 / 0 67 / 8 58 / / 5 44 / 4 9 / 6 5 / F / / 8 7 / / / 9 76 / 9 65 / / 6 50 / / 4 40 / 5 Notes: ) Minimum exterior bearing length required is.50 inches. Minimum interior bearing length is.00 inches. If these minimum lengths are not provided, web crippling must be checked. ) FM Global approved spans available on page. 4 AUG 08

15 .5A ROOF DECK Maximum Sheet Length 4-0 Extra charge for lengths under 6-0 ICC ESR-7 FM Global Approved DIMENSIONS SECTION PROPERTIES Type Design Thickness (in.) Weight (psf) Section Properties I p S p I n S n (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) V a (lbs/ft) A A A A F y (ksi) ROOF VERTICAL LOADS FOR TYPE.5A No. of Spans Type Max. SDI Const. Span Allowable Total Load (psf) / Load Causing Deflection of L/40 or inch (psf) Span (ft-in.) ctr to ctr of supports A '-9 8 / / 75 5 / 55 4 / 4 6 / / 5 6 / 0 / 6 0 / 8 / 6 / 9 A0 4'-8 00 / 7 79 / / 70 5 / 5 45 / 4 8 / / 6 9 / 5 / 7 / 4 0 / A9 5'-6 9 / / 7 76 / 85 6 / 64 5 / / 9 9 / 4 / 5 0 / 6 / 7 4 / 5 A8 6'- 8 / / 7 88 / 00 7 / 75 6 / 58 5 / / 6 9 / 0 4 / 4 0 / 0 7 / 7 A 4'-7 87 / / / 4 46 / 06 9 / 8 / 64 8 / 5 5 / 4 / 5 9 / 9 7 / 4 A0 5'-9 06 / / 4 68 / / 47 / 0 40 / 80 5 / 64 0 / 5 7 / 4 4 / 6 / 0 A9 6'-0 4 / 4 98 / / 0 66 / / 47 / 96 4 / 77 6 / 6 / 5 8 / 4 5 / 6 A8 7'-4 40 / 47 / 90 / 4 75 / 8 6 / 40 5 / 0 46 / / 7 5 / 59 / 49 8 / 4 A 4'-7 08 / 6 85 / 5 69 / 57 / 8 48 / 64 4 / 50 5 / 40 / 7 / 7 4 / / 9 A0 5'-9 / / / 8 70 / / / 6 44 / 50 8 / 4 / 4 0 / 8 6 / 4 A9 6'-0 55 / / 6 99 / 65 8 / 4 69 / / 75 5 / / 49 9 / 40 5 / 4 / 8 A8 7'-4 75 / 70 8 / 60 / 90 9 / 4 78 / 0 67 / / / / 46 9 / 9 5 / Notes: ) Minimum exterior bearing length required is.50 inches. Minimum interior bearing length is.00 inches. If these minimum lengths are not provided, web crippling must be checked. ) FM Global approved spans available on page. AUG 08 5

16 .0D DOVETAIL DECK Maximum Sheet Length 4-0 Extra charge for lengths under 6-0 IAPMO ER-04 FM Global Approved DIMENSIONS ROOF SECTION PROPERTIES Type Design Thickness (in.) Weight (psf) Section Properties I d+ S e+ I d- S e- (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) V a (lbs/ft).0d D D D F y (ksi) VERTICAL LOADS FOR TYPE.0D No. of Spans Type Allowable Total Load (psf) / Load Causing Deflection of L/40 (psf) Span (ft-in.) ctr to ctr of supports D 74 / / 8 89 / / / 5 4 / 5 6 / 9 0 / 5 6 / / 9 D0 9 / 5 / 4 / / 6 68 / 4 55 / 45 / 8 / 8 / 4 8 / D8 96 / 05 / 90 5 / 0 6 / 80 9 / / 4 6 / 5 / 4 44 / 9 8 / 5 D6 75 / 60 / 4 9 / 5 46 / 0 6 / 7 94 / 5 77 / 9 65 / 0 55 / 4 48 / 9 D 74 / / 89 / 68 / 54 / 4 / 6 / 0 / 6 / / D0 / 48 / 09 / 8 / 66 / 5 / 44 / 7 / / 7 / 6 D8 87 / 00 / 47 / / 89 / 7 / 59 / 50 / 4 / 7 / 5 D6 68 / 55 / 88 / 44 / 4 / 9 / 76 / 64 / 54 / 47 / 46 D 7 / 5 / / 85 / 67 / 6 54 / / 8 / 6 / 0 8 / 6 D0 67 / 85 / 6 / 04 / 8 / / / 4 46 / 9 / 5 4 / 0 D8 59 / 50 / 8 / 40 / / / / 57 6 / 44 5 / 4 46 / 8 D6 460 / 9 / 5 / 80 / 4 / 4 5 / / / / / 6 Notes: ) This table does not account for web-crippling. Allowable reactions must be checked based on specific span condition using the allowable reactions shown in the Vulcraft DoveTail Roof Catalog, available at: ) FM Global approved spans are available at: ) The symbol indicates that the allowable uniform load based on deflection exceeds the allowable load based on stress. See for more complete DoveTail deck information. 6 AUG 08

17 .5D DOVETAIL DECK Maximum Sheet Length 4-0 Extra charge for lengths under 6-0 IAPMO ER-04 FM Global Approved DIMENSIONS SECTION PROPERTIES Type Design Thickness (in.) Weight (psf) Section Properties I d+ S e+ I d- S e- (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) V a (lbs/ft).5d D D D F y (ksi) ROOF VERTICAL LOADS FOR TYPE.5D No. of Spans Type Allowable Total Load (psf) / Load Causing Deflection of L/40 (psf) Span (ft-in.) ctr to ctr of supports D0 89 / / / 5 55 / 4 48 / 4 4 / 8 7 / 4 / 0 0 / 7 7 / 4 4 /.5D8 9 / 9 09 / 9 9 / 7 80 / / 47 6 / 9 54 / 48 / 7 4 / 9 / 0 5 / 7.5D6 74 / / 9 4 / / 75 9 / 6 8 / 50 7 / 4 65 / 5 58 / 0 5 / 6 48 /.5D4 0 / 95 9 / / 8 4 / 95 4 / / 6 96 / 5 86 / / 8 70 / 6 / 8.5D0 0 / 87 / 74 / 64 / 55 / 49 / 4 / 8 / 5 / / 8 / 8.5D8 4 / 9 / 0 / 87 / 76 / 67 / 59 / 5 / 47 / 4 / 9 /.5D6 8 / 5 / 0 / / 98 / 86 / 76 / 68 / 6 / 55 / 50 /.5D4 / 94 / 65 / 4 / 4 / 09 / 97 / 86 / 77 / 70 / 6 /.5D0 / 08 / 9 / 80 / 74.5D8 77 / 48 / 6 / 09 / 0.5D6 77 / 9 / 6 / 40 / 4.5D4 89 / 4 / 07 / 78 / 7 Notes: ) This table does not account for web-crippling. Allowable reactions must be checked based on specific span condition using the allowable reactions shown in the Vulcraft DoveTail Roof Catalog, available at: ) FM Global approved spans are available at: ) The symbol indicates that the allowable uniform load based on deflection exceeds the allowable load based on stress. See for more complete DoveTail deck information. AUG 08 7

18 .0E ROOF DECK Maximum Sheet Length 4-0 Extra charge for lengths under 6-0 ICC ESR-7 FM Global Approved DIMENSIONS ROOF SECTION PROPERTIES Type Design Thickness (in.) Weight (psf) Section Properties I p S p I n S n (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) V a (lbs/ft) E E E E F y (ksi) VERTICAL LOADS FOR TYPE.0E No. of Spans Type Max. SDI Const. Span Allowable Total Load (psf) / Load Causing Deflection of L/40 or inch (psf) Span (ft-in.) ctr to ctr of supports E6 '-0 57 / / 97 / 6 00 / 4 79 / 9 64 / 5 / 6 45 / 8 / 0 / 8 9 / 6 E4 '-5 76 / 9 6 / 8 9 / / 58 6 / 4 94 / 0 78 / 65 / 7 56 / 4 48 / 4 / 9 E ' / / / 95 / / 5 5 / 8 0 / 9 86 / 74 / 7 64 / 4 55 / E0 4'- 640 / / 4 7 / 5 50 / / 6 60 / 46 / 5 / 7 95 / 8 / 7 7 / 4 E6 '-4 67 / / 40 8 / 5 06 / 0 84 / 7 68 / 5 56 / 9 47 / 0 40 / 4 5 / 9 0 / 5 E4 4'-0 90 / / 9 00 / 4 5 / 4 / 0 98 / 7 8 / / 4 58 / 50 / 7 44 / E 4' / 78 5 / / / / 7 8 / 9 06 / / 5 76 / 4 65 / 4 57 / 7 E0 5'-0 6 / / 55 0 / 4 46 / 7 94 / 5 58 / 0 / / 64 9 / 5 8 / 4 70 / E6 '-4 0 / 5 / 88 7 / 8 / / / 4 70 / 0 59 / 50 / 8 4 / 5 8 / E4 4' / / / 67 9 / 5 / 79 / 57 0 / 4 85 / 7 / 6 6 / 55 / 7 E 4'-6 69 / / 4 4 / 49 / 4 97 / / 7 / 54 / 4 95 / 8 / 6 7 / E0 5' / / / / 70 4 / 9 97 / 87 6 / 65 7 / 50 7 / 40 0 / 88 / 6 Notes: ) Minimum exterior bearing length required is.50 inches. Minimum interior bearing length is.00 inches. If these minimum lengths are not provided, web crippling must be checked. 8 AUG 08

19 ROOF DECK FIRE RESISTANCE RATINGS Restrained Assembly Rating Type of Protection Type of Insulation U.L. Design No. (,) Roof Unrestrained Beam Rating Restrained Assembly Rating Type of Protection Type of Insulation U.L. Design No. (,) Roof Unrestrained Beam Rating Hr. Exposed Grid Gypsum Board Cementitious Sprayed Fiber Unprotected Exposed Grid Rigid Insulation Insulating Fill Rigid Insulation Rigid Insulation Rigid Insulation Insulating Fill Rigid Insulation P+ B, BI, F, A P4+ B, BI, F, A Hr. P5+ B, BI, F, A,.5 Hr. P7+ B, BI, F, A,.5 Hr. P0+ B, BI, F, A Hr. P5+ B, BI, F, A Hr. P4+ B, BI, F, A Hr. P50+ B, BI, F, A P70* B, BI, F, A, N, NI,.5, Hr. P7* B, BI, F, N, NI,.5, Hr. P77* B, BI, N, NI,.5, Hr. P80* B, BI, F, A, N, NI,.5, Hr. P85* B, BI, F, A, N, NI,.5, Hr. P89* B, BI, F, N, NI,.5, Hr. P90 B, BI, N, NI,.5, Hr. P907 B, BI, N, NI,.5, Hr. P908 B, BI, N, NI,.5, Hr. P99 B, BI, N, NI,.5 Hr. P90 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr. P5+ B, BI, F, A,.5 Hr. P7+ B, BI, F, A,.5 Hr. P0+ B, BI, F, A Hr. Hr. Exposed Grid Metal Lath Gypsum Board Cementitious Sprayed Fiber Unprotected Hr. Metal Lath Rigid Insulation Rigid Insulation Rigid Insulation Rigid Insulation Rigid Insulation Insulating Fill Insulating Fill P7+ B, BI, F, A Hr. P404+ B, BI P54+ B, BI, F, A P70 B, BI, F, A, N, NI,.5, Hr. P7* B, BI, F, N, NI,.5, Hr. P77* B, BI, N, NI,.5, Hr. P80 B, BI, F, A, N, NI,.5, Hr. P85* B, BI, F, A, N, NI,.5, Hr. P89* B, BI, F, N, NI,.5, Hr. P90 B, BI, N, NI,.5, Hr. P907 B, BI, N, NI,.5, Hr. P908 B, BI, N, NI,.5, Hr. P90 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr Notes:. Refer to the U.L. Fire Resistance Directory for the necessary construction details.. finish shall be galvanized unless noted otherwise.. + finish is not critical for fire resistance when used in P--, P4--, & P5-- Series designs. finish shall be galvanized or painted. * Denotes deck finish is critical for fire resistance. finish shall be galvanized or painted. This is a special type of paint and is compatible with the spray-applied fire protection and is U.L. approved for use in the denoted P7-- & P8-- Series designs. ROOF Metal Lath Rigid Insulation P404+ B, BI Gypsum Board Rigid Insulation P50+ B, BI, F, A Cementitious Rigid Insulation P70* B, BI, F, A, N, NI,.5, Hr. P7* B, BI, F, N, NI,.5, Hr. P77* B, BI, N, NI,.5, Hr. / Hr. Sprayed Fiber Rigid Insulation P80* B, BI, F, A, N, NI,.5, Hr. P85* B, BI, F, A, N, NI,.5, Hr. P89* B, BI, F, N, NI,.5, Hr. P90 B, BI, N, NI,.5, Hr. P907 B, BI, N, NI,.5, Hr. P908 B, BI, N, NI,.5, Hr. Unprotected Insulating Fill P99 B, BI, N, NI,.5 Hr. P90 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr. P9 B, BI, N, NI,.5, Hr. AUG 08 9

20 ROOF DECK WEB CRIPPLING ROOF Type B4 B B0 B9 B8 B6 F F0 F9 F8 A A0 A9 A8 Reaction Type Allowable Reactions Due to Web Crippling (lbs/ft) One Flange Loading Bearing Length (in.) Two Flange Loading Bearing Length (in.) End Interior End Interior End Interior End Interior End Interior End Interior End Interior End Interior End Interior End Interior End Interior End Interior End Interior End Interior Type N N0 N9 N8 N6 Reaction Type Allowable Reactions Due to Web Crippling (lbs/ft) One Flange Loading Bearing Length (in.) Two Flange Loading Bearing Length (in.) End Interior End Interior End Interior End Interior End Interior AUG 08

21 BEARING Bearing length directly influences allowable reactions governed by web crippling. It is also important to ensure that enough bearing length is provided to meet minimum edge distance requirements for fasteners. Sufficient bearing at parallel supports should be provided to make the specified connections. Web Crippling: One vs. Two Flange Loading ROOF AUG 08

22 ROOF ROOF DECK ACCESSORIES ACCESSORIES AUG 08

23 FM GLOBAL The tables below provide an abbreviated listing of FM approved spans (c-c) for Vulcraft decks based on live load deflection and wind uplift limited by deck bending and fastener pull-over. The complete listing of FM allowable spans for Vulcraft decks, including additional profiles and alternate weld sizes is available at The Engineer of Record must investigate the design, including above deck components and selected attachments, as published by FM Global as found at No. of Spans ALLOWABLE SPANS (c-c) 5/8 Arc Spot 6/4 5/8 Arc Spot 6/ (B,BI) (B,BI) (B,BI) (B,BI) (B,BI) (B,BI) (B,BI) (B,BI) (B,BI) (B,BI) (B,BI) (B,BI) ROOF No. of Spans 5/8 Arc Spot 4/ (N,NI) (N,NI) (N,NI) (N,NI) (N,NI) (N,NI) (N,NI) (N,NI) (N,NI) (N,NI) (N,NI) (N,NI) NOTES: ) Arc spot weld sizes are visible diameter. ) FM Global reduces deck section properties by 5% to account for acoustical perforations. Additional decks approved for use in FM constructions include: Fluted:.5A,.5F,.0D, and.5d Fluted Acoustical:.5BA,.5BIA, NA, NIA,.0DA, and.5da Cellular:.5BP and NP Cellular Acoustical:.5BPA and NPA AUG 08

24 0.6C / 0.6CSV CONFORM DECK SECTION PROPERTIES Gauge Design Thickness Weight Section Properties Ip I n S p S n (in) (psf) (in 4 /ft) (in 4 /ft) (in /ft) (in /ft) (lbs/ft) (ksi) V a F y NON-COMPOSITE MAXIMUM CONSTRUCTION CLEAR SPANS (S.D.I. CRITERIA) (ft-in.) Total Slab Depth (t=.50).5 (t=.00) (t=.50).5 (t=.00) 4 (t=.50) 4.5 (t=4.00) 5 (t=4.50) Weight (psf) NW Concrete N=9 45 PCF Weight (psf) LW Concrete N=4 0 PCF SPAN SPAN SPAN SPAN SPAN SPAN 0.6C8 '- '-9 '-0 7 '-4 '-0 '- 0.6C6 '-9 '- '-4 8 '-0 '-5 '-6 0.6C4 '-5 4'- 4'- 8 '-7 4'-4 4'-5 0.6C 4'- 4'-0 4'- 8 4'- 5'- 5'- 0.6C8 9 '- '-8 '-8 '-4 '-9 '-0 0.6C6 9 '-8 '- '- '-9 '-4 '-4 0.6C4 9 '-4 '- 4'-0 '-6 4'- 4'- 0.6C 9 '- 4'-7 4'-8 4'- 4'- 5'-0 0.6C8 5 '- '-7 '-7 7 '- '-8 '-9 0.6C6 5 '-7 '- '- 7 '-8 '- '- 0.6C4 5 '- '-9 '-0 7 '-5 4'-0 4'- 0.6C 6 '-9 4'-5 4'-6 7 4'-0 4'-9 4'-0 0.6C8 4 '- '-6 '-6 '- '-8 '-8 0.6C6 4 '-6 '- '-0 '-7 '- '- 0.6C4 4 '- '-8 '-8 '- '- '- 0.6C 4 '-7 4'- 4'-4 '-0 4'-7 4'-8 0.6C8 47 '-0 '-5 '-6 6 '- '-7 '-7 0.6C6 47 '-5 '-0 '- 6 '-7 '- '- 0.6C4 47 '-0 '-6 '-7 6 '- '-9 '-0 0.6C 48 '-5 4'- 4'- 6 '-9 4'-5 4'-6 0.6C8 5 '-0 '-4 '-5 40 '- '-6 '-7 0.6C6 5 '-4 '-9 '-0 40 '-6 '-0 '-0 0.6C4 5 '- '-5 '-6 4 '- '-8 '-9 0.6C 54 '-4 4'-0 4'-0 4 '-7 4'- 4'-4 0.6C8 59 '- '-4 '-4 45 '- '-6 '-6 0.6C6 59 '- '-8 '-9 45 '-5 '- '- 0.6C4 59 '-0 '-4 '-4 45 '-0 '-7 '-8 0.6C 60 '- '-0 '- 46 '-6 4'- 4'- Notes: ) Minimum exterior bearing length required is.5. Minimum interior bearing length is. See page 7 for Reinforced Concrete Slab Allowable Loads for 0.6C. 4 AUG 08

25 0.6C / 0.6CSV CONFORM DECK DIMENSIONS ALLOWABLE UNIFORM LOAD (PSF) TYPE NO. 0.6C8 0.6C6 0.6C4 0.6C NO. OF SPANS DESIGN CRITERIA SLAB INFORMATION Total Slab Depth CLEAR SPAN (ft-in.) Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) / / / *Volumes and weights do not include allowance for deflection Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ NON-COMPOSITE AUG 08 5

26 SECTION PROPERTIES Gauge.0C /.0CSV CONFORM DECK Design Thickness Weight Section Properties Ip I n S p S n (in) (psf) (in 4 /ft) (in 4 /ft) (in /ft) (in /ft) (lbs/ft) (ksi) V a F y NON-COMPOSITE MAXIMUM CONSTRUCTION CLEAR SPANS (S.D.I. CRITERIA) (ft-in.) Total Slab Depth.5 (t=.50) (t=.00).5 (t=.50) 4 (t=.00) 4.5 (t=.50) 5 (t=4.00) 5.5 (t=4.50) Weight (psf) NW Concrete N=9 45 PCF Weight (psf) LW Concrete N=4 0 PCF SPAN SPAN SPAN SPAN SPAN SPAN.0C6 5 '-0 4'-7 4'-8 9 4'- 4'- 5'-0.0C4 5 5'- 6'- 6'- 9 5'-6 6'-7 6'-8.0C 5 6'-0 7'-6 7'-5 0 6'-7 8'- 8'-.0C0 6 6'-5 8'-7 7'- 0 7'-0 9'-4 8'-8.0C6 '-8 4'-5 4'-6 4 '- 4'-8 4'-9.0C4 4'- 5'-0 5'- 4 5'-4 6'- 6'-4.0C 5'-8 7'- 7'-0 4 6'- 7'-9 7'-8.0C0 6'-0 8'-0 7'-5 5 6'-7 8'-0 8'-.0C6 7 '-7 4'- 4'- 8 '-0 4'-6 4'-7.0C4 7 4'-9 5'-7 5'-8 9 5'- 6'-0 6'-.0C 7 5'-4 6'-9 6'-7 9 5'-0 7'-4 7'-.0C0 8 5'-8 7'-7 7'-0 9 6'- 8'-4 7'-8.0C6 4 '-5 4'- 4'- '-8 4'-5 4'-5.0C4 4 4'-6 5'-4 5'-5 4'- 5'-0 5'-0.0C 4 5'- 6'-6 6'-4 5'-7 7'- 6'-.0C0 44 5'-5 7'- 6'-8 4 5'- 8'-0 7'-4.0C6 49 '-4 '- 4'-0 7 '-7 4'- 4'-4.0C4 49 4'-4 5'- 5'- 8 4'-9 5'-7 5'-8.0C 50 4'- 6'- 6'- 8 5'-4 6'-0 6'-8.0C0 50 5'- 7'-0 6'-5 8 5'-8 7'-8 7'-.0C6 55 '- '-0 '-0 4 '-6 4'- 4'-.0C4 55 4'- 5'-0 5'-0 4 4'-7 5'-5 5'-6.0C 56 4'-9 6'-0 5'-0 4 5'- 6'-7 6'-5.0C0 56 5'-0 6'-9 6'- 4 5'-6 7'-5 6'-0.0C6 6 '- '-8 '-9 47 '-5 4'-0 4'-.0C4 6 4'- 4'-0 4' '-6 5'- 5'-4.0C 6 4'-7 5'-9 5' '-0 6'-4 6'-.0C0 6 4'-0 6'-6 6' '-4 7'- 6'-7 Notes: ) Minimum exterior bearing length required is.5. Minimum interior bearing length is. See page 7 for Reinforced Concrete Slab Allowable Loads for.0c. 6 AUG 08

27 .0C /.0CSV CONFORM DECK DIMENSIONS ALLOWABLE UNIFORM LOAD (PSF) TYPE NO..0C6.0C4.0C.0C0 NO. OF SPANS DESIGN CRITERIA CLEAR SPAN (ft-in.) SLAB INFORMATION Total Slab Depth Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) / / / / *Volumes and weights do not include allowance for deflection Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ NON-COMPOSITE AUG 08 7

28 SECTION PROPERTIES Gauge.C /.CSV CONFORM DECK Design Thickness Weight Section Properties Ip I n S p S n (in) (psf) (in 4 /ft) (in 4 /ft) (in /ft) (in /ft) (lbs/ft) (ksi) V a F y NON-COMPOSITE MAXIMUM CONSTRUCTION CLEAR SPANS (S.D.I. CRITERIA) (ft-in.) Total Slab Depth. (t=.00).8 (t=.50) 4. (t=.00) 4.8 (t=.50) 5. (t=4.00) 5.8 (t=4.50) 6. (t=5.00) Weight (psf) NW Concrete N=9 45 PCF Weight (psf) LW Concrete N=4 0 PCF SPAN SPAN SPAN SPAN SPAN SPAN.C6 4'-0 5'-8 5'-9 5 5'- 6'- 6'-.C4 4 6'-0 7'- 7'- 6 6'-6 7'-8 7'-9.C 4 6'-5 8'- 8'-0 6 7'- 8'- 8'-9.C0 4 6'-0 9'-0 8'-6 6 7'-6 9'-0 9'-4.C6 9 4'-8 5'-5 5'-6 0 5'-0 5'- 6'-0.C4 40 5'-9 6'-9 6'-0 0 6'- 7'-4 7'-5.C 40 6'- 7'-9 7'-7 6'-9 8'-6 8'-4.C0 40 6'-6 8'-7 8'- 7'- 9'-5 8'-0.C6 45 4'-5 5'- 5'-4 5 4'-0 5'-8 5'-9.C4 46 5'-6 6'-5 6'-6 5 6'-0 7'- 7'-.C 46 5'-0 7'-5 7'- 5 6'-5 8'- 7'-.C0 46 6'- 8'- 7'-9 6 6'-0 9'-0 8'-6.C6 5 4'-4 5'-0 5'- 9 4'-8 5'-6 5'-7.C4 5 5'- 6'- 6'- 40 5'-9 6'-0 6'-.C 5 5'-8 7'- 7' '- 7'-0 7'-8.C0 5 6'-0 7'-0 7' '-7 8'-8 8'-.C6 57 4'- 4'-6 4'- 44 4'-6 5'-4 5'-5.C4 58 5'- 6'-0 6'- 44 5'-7 6'-7 6'-8.C 58 5'-5 6'-0 6' '-0 7'-7 7'-5.C0 58 5'-0 7'-7 7'- 45 6'-4 8'-4 7'-0.C6 6 4'-0 4'- 4' '-5 5'- 5'-.C4 64 4'- 5'-9 5' '-5 6'-4 6'-5.C 64 5'- 6'-7 6' '-9 7'-4 7'-.C0 64 5'-7 7'- 6'- 49 6'- 8'- 7'-7.C6 69 '- '-9 4'- 5 4'- 4'- 5'-.C4 70 4'-9 5'-7 5'-8 5 5'- 6'- 6'-.C 70 5'- 6'-5 6' '-7 7'- 6'-.C0 70 5'-6 7'- 6' '-0 7'-0 7'-5 Notes: ) Minimum exterior bearing length required is.5. Minimum interior bearing length is. See page 8 for Reinforced Concrete Slab Allowable Loads for.c. 8 AUG 08

29 .C /.CSV CONFORM DECK DIMENSIONS ALLOWABLE UNIFORM LOAD (PSF) TYPE NO..C6.C4.C.C0 NO. OF SPANS DESIGN CRITERIA SLAB INFORMATION Total Slab Depth CLEAR SPAN (ft-in.) Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) *Volumes and weights do not include allowance for deflection Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ Fb = 6, Defl. = l/ Defl. = l/ NON-COMPOSITE AUG 08 9

30 .5C CONFORM DECK SECTION PROPERTIES Gauge Design Thickness Weight Section Properties Ip I n S p S n (in) (psf) (in 4 /ft) (in 4 /ft) (in /ft) (in /ft) (lbs/ft) (ksi) V a F y NON-COMPOSITE MAXIMUM CONSTRUCTION CLEAR SPANS (S.D.I. CRITERIA) (ft-in.) Total Slab Depth.5 (t=.00) 4 (t=.50) 4.5 (t=.00) 5 (t=.50) 5.5 (t=4.00) 6 (t=4.50) 6.5 (t=5.00) Weight (psf) NW Concrete N=9 45 PCF Weight (psf) LW Concrete N=4 0 PCF SPAN SPAN SPAN SPAN SPAN SPAN.5C4 7 5'-0 6'-0 6'- 8 6'-4 7'-6 7'-7.5C 7 6'-4 7'-4 7'-6 9 6'-0 8'-0 8'-.5C0 8 7'-5 8'-5 8'-8 9 8'- 9'- 9'-6.5C8 8 8'-5 9'-9 0'- 0 9'- 0'-8 '-0.5C4 4 5'-7 6'-6 6'-8 6'- 7'- 7'-.5C 4 6'-0 7'-0 7'- 6'-7 7'-8 7'-0.5C0 44 7'- 8'-0 8'- 4 7'-9 8'-9 9'-.5C8 44 8'-0 9'-4 9'-8 4 8'-9 0'- 0'-6.5C4 49 5'-4 6'- 6'-4 8 5'-0 6'-0 7'-0.5C 49 5'-9 6'-8 6'-0 8 6'-4 7'-4 7'-6.5C0 50 6'-9 7'-8 7'- 8 7'-5 8'-5 8'-8.5C8 50 7'-9 8'- 9'- 9 8'-5 9'-0 0'-.5C4 55 5'- 6'-0 6'- 4 5'-8 6'-7 6'-9.5C 55 5'-7 6'-5 6'-7 4 6'- 7'- 7'-.5C0 56 6'-6 7'-4 7'-7 4 7'- 8'- 8'-5.5C8 56 7'-5 8'-7 8'-0 4 8'- 9'-5 9'-9.5C4 6 5'-0 5'-9 5'- 47 5'-6 6'-5 6'-6.5C 6 5'-5 6'- 6' '- 6'-0 7'-0.5C0 6 6'- 7'- 7' '- 7'-0 8'-.5C8 6 7'- 8'- 8' '- 9'- 9'-5.5C4 67 4'-0 5'-7 5'-9 5 5'-4 6'- 6'-4.5C 68 5'- 6'-0 6'- 5 5'-9 6'-8 6'-0.5C0 68 6'- 6'-0 7'- 5 6'-9 7'-7 7'-0.5C8 69 7'-0 8'-0 8'- 5 7'-8 8'-0 9'-.5C4 7 4'-9 5'-5 5' '- 6'-0 6'-.5C 74 5'- 5'-9 6' '-7 6'-5 6'-7.5C0 74 5'- 6'-7 6' '-6 7'-4 7'-7.5C8 75 6'-0 7'-9 8' '-5 8'-7 8'- Notes: ) Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for 4 to 6 gage. Minimum interior bearing length of for 4 to 6 gage. See page 8 for Reinforced Concrete Slab Allowable Loads for.5c. 0 AUG 08

31 .5C CONFORM DECK DIMENSIONS ALLOWABLE UNIFORM LOAD (PSF) TYPE NO..5C4.5C.5C0.5C8 NO. OF SPANS DESIGN CRITERIA CLEAR SPAN (ft-in.) SLAB INFORMATION Total Slab Depth Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) / / / / *Volumes and weights do not include allowance for deflection Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ NON-COMPOSITE AUG 08

32 C CONFORM DECK SECTION PROPERTIES Gauge Design Thickness Weight Section Properties Ip I n S p S n (in) (psf) (in 4 /ft) (in 4 /ft) (in /ft) (in /ft) (lbs/ft) (ksi) V a F y NON-COMPOSITE MAXIMUM CONSTRUCTION CLEAR SPANS (S.D.I. CRITERIA) (ft-in.) Total Slab Depth 4 (t=.00) 4.5 (t=.50) 5 (t=.00) 5.5 (t=.50) 6 (t=4.00) 6.5 (t=4.50) 7 (t=5.00) Weight (psf) NW Concrete N=9 45 PCF Weight (psf) LW Concrete N=4 0 PCF SPAN SPAN SPAN SPAN SPAN SPAN C 8 7'-0 9'-0 9'- 9 8'-7 9'-0 0'- C0 9 9'-5 0'-5 0'-9 0 0'-4 '-4 '-9 C8 9 0'-6 '-8 '-6 0 '-5 '-9 '-5 C6 40 '- '-0 '- '- 4'-0 4'- C 44 7'-6 8'-7 8'-0 4 8'- 9'-5 9'-9 C0 45 9'-0 9'- 0'- 4 9'- 0'- '- C8 45 0'- '- '- 5 '-0 '- '- C6 46 0'-0 '- '-8 6 '-8 '-5 '-8 C 50 7'- 8'- 8'-5 8 7'-0 9'- 9'-4 C0 5 8'-7 9'-6 9'-0 9 9'-6 0'-5 0'-0 C8 5 9'-8 '-6 '-9 9 0'-7 '-8 '-7 C6 5 0'-5 '-9 '- 40 '-4 '- '- C 56 6'-0 7'- 8'- 4 7'-7 8'-9 8'- C0 57 8'- 9'- 9'-5 4 9'- 0'- 0'-5 C8 57 9'-4 '- ' '- '- '- C6 58 0'-0 '- '-8 45 '-0 '-5 '-0 C 6 6'-7 7'-7 7' '-4 8'-5 8'-8 C0 6 7'- 8'-9 9'- 48 8'-9 9'-9 0'- C8 6 9'-0 0'-8 ' '- '-0 '- C6 64 9'-9 0'-0 '- 49 0'-8 '-0 '-5 C 68 6'-5 7'-4 7'-6 5 7'- 8'- 8'-4 C0 69 7'-8 8'-6 8'-9 5 8'-6 9'-5 9'-9 C8 69 8'-9 0'-4 0'-8 5 9'-7 '-5 '-8 C6 70 9'-5 0'-6 0' '-4 '-8 '-0 C 74 6'- 7'- 7' '- 7'- 8'- C0 75 7'-5 8'- 8' '- 9'- 9'-5 C8 75 8'-6 0'-0 0' '-4 '- '-5 C6 76 9'- 0'- 0' '- '-4 '-8 Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: For Normal Weight Concrete: Minimum exterior bearing length of.5 for 0 to 6 gage. Minimum end bearing varies from.5 to.875 for gage, depending on slab thickness. Minimum interior bearing length of for 9 to 6 gage. Minimum interior bearing varies from to 5.65 for 0 and gage, depending on gage and slab thickness. For Lightweight Concrete: Minimum exterior bearing length of.5 for to 6 gage. Minimum interior bearing length of for 9 to 6 gage. Minimum interior bearing varies from to 4.5 for 0 to gage, depending on slab thickness. See page 9 for Reinforced Concrete Slab Allowable Loads for C. AUG 08

33 C CONFORM DECK DIMENSIONS ALLOWABLE UNIFORM LOAD (PSF) TYPE NO. C C0 C8 C6 NO. OF SPANS DESIGN CRITERIA SLAB INFORMATION Total Slab Depth CLEAR SPAN (ft-in.) Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) / / / *Volumes and weights do not include allowance for deflection Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ NON-COMPOSITE AUG 08

34 C CONFORM DECK SECTION PROPERTIES Gauge Design Thickness Weight Section Properties Ip I n S p S n (in) (psf) (in 4 /ft) (in 4 /ft) (in /ft) (in /ft) (lbs/ft) (ksi) V a F y NON-COMPOSITE MAXIMUM CONSTRUCTION CLEAR SPANS (S.D.I. CRITERIA) (ft-in.) Total Slab Depth 5 (t=.00) 5.5 (t=.50) 6 (t=.00) 6.5 (t=.50) 7 (t=4.00) 7.5 (t=4.50) 8 (t=5.00) Weight (psf) NW Concrete N=9 45 PCF Weight (psf) LW Concrete N=4 0 PCF SPAN SPAN SPAN SPAN SPAN SPAN C 44 0'-0 0'-9 '- 4 '-0 '-0 '- C0 44 '-8 '-5 '-0 4 '-6 '-8 4'- C8 45 '-7 5'- 4'-9 5 '-6 6'-7 5'-0 C6 46 '-4 5'- 5'-7 6 4'- 6'-8 6'-8 C 50 9'-6 9'- 0'-7 8 0'-7 '-4 '-8 C0 50 '- '- '-4 9 '- '- '-7 C8 5 '- 4'-6 4'-4 9 '- 5'- 5'-4 C6 5 '- 4'-7 5'- 40 '-0 6'-0 6'- C 56 9'- 9'- 0'- 4 0'- 0'- '- C0 56 0'-9 '-5 '-0 4 '-0 '-8 '- C8 57 '- '- 4'-0 44 '-9 5'-4 4'- C6 58 '-7 4'-0 4'-6 45 '-6 5'-6 5'-9 C 6 8'-9 8'-6 9' '-9 0'-5 0'-0 C0 6 0'-4 '-0 '-4 48 '-6 '- '-7 C8 6 '-8 '-5 '-8 49 '-5 4'-0 4'-7 C6 64 '-4 '-6 4'-0 49 '- 4'- 5'-5 C 68 8'-6 7'- 9'-0 5 9'-5 9'-9 0'-6 C0 69 0'-0 0'-8 '-0 5 '- '-0 '- C8 69 '-5 '-0 '-4 5 '- 4'-5 4'- C6 70 '- '- '-6 54 '- 4'-6 5'-0 C 74 8'- 7'-5 8' '- 9'- 0'- C0 75 9'-8 0'- 0' '-0 '-6 '-0 C8 75 '- '-7 '-0 58 '- 4'-0 4'-0 C6 76 '-0 '-8 '- 58 '-8 4'- 4'-6 C 80 7'- 7'-0 8'-0 6 8'- 8'-8 9'-0 C0 8 9'-4 0'-0 0'-4 6 0'-6 '- '-6 C8 8 0'-0 '- '-7 6 '-9 '-7 '-9 C6 8 '-7 '- '-8 6 '-5 '-8 4'- Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: For Normal Weight Concrete: Minimum exterior bearing length of.5 for 9 to 6 gage. Minimum end bearing varies from.5 to.75 for and 0 gage, depending on slab thickness. Minimum interior bearing length of for 6 gage. Minimum interior bearing varies from to 6.5 for 8 to gage, depending on gage and slab thickness. For Lightweight Concrete: Minimum exterior bearing length of.5 for 0 to 6 gage. Minimum end bearing is.5 to.75 for gage, epending on gage and slab thickness. Minimum interior bearing length of for 8 and 6 gage. Minimum end bearing varies from to 6.5 for to 9 gage, depending on gage and slab thickness. See page 9 for Reinforced Concrete Slab Allowable Loads for C. 4 AUG 08

35 C CONFORM DECK DIMENSIONS ALLOWABLE UNIFORM LOAD (PSF) TYPE NO. C C0 C8 C6 NO. OF SPANS DESIGN CRITERIA CLEAR SPAN (ft-in.) SLAB INFORMATION Total Slab Depth Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) / / / *Volumes and weights do not include allowance for deflection Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 0, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ Fb = 4, Defl. = l/ Defl. = l/ NON-COMPOSITE AUG 08 5

36 NON-COMPOSITE CONFORM (TYPE C ) SLAB DESIGN UNDRAPED DRAPED NON-COMPOSITE Design Notes for Reinforced Concrete Slabs. Design of concrete slabs in accordance with ACI is the responsibility of the structural engineer of record. Values listed in this catalog are provided as an aid in selecting the appropriate deck and Vulcraft does not assume responsibility for the design of the slab.. Temperature and shrinkage effects in the concrete shall be controlled by methods permitted by ACI 8. The designer shall be permitted to consider only the area of concrete above the deck.. Shoring-Slabs temporarily shored during construction must deduct the weight of the slab from the capacity of the reinforced concrete slab. 4. Finish-Galvanized form deck can be considered a permanent support in most applications. When uncoated or painted deck is used, the weight of the concrete slab shall be deducted from the calculated capacity of the slab. 5. Allowable Slab Loads-These tables are based on an interior three span condition using moment coefficients from ACI 8-4 Section Moment coefficients must be adjusted for end spans, single spans, or double spans. f c =,000 psi f y = 60,000 psi ɸ = 0.90 T = A s f y b = in a = T/0.85 f c b + M = /6W L - M = /W L (L 0 ft.) - M = /0W L (L>0 ft.) + M c = T (d-a/)/ - M c = T (d-na)/ M L = ɸ M c /.6 6. Serviceability-Tabulated values are not evaluated for deflection. Values highlighted in red do not meet the requirements of ACI 8-4 Section 7.. for minimum slab thickness. REINFORCED CONCRETE SLAB TABLE FOOTNOTES:. Design of concrete slabs in accordance with ACI is the responsibility of the structural engineer of record. Values listed in this table are provided as an aid in selecting the appropriate deck and Vulcraft does not assume responsibility for the design of the slab.. Superimposed loads are based upon an three span condition and ACI 8-4 Section 6.5. moment coefficients. Load values for single span or double span conditions are to be reduced.. Deduct weight of slab from table values if deck is not galvanized or if deck is shored during construction. 4. The concrete cover thickness (t) for the table values shown meet the ratio of span/8 per ACI 8-4 Section Reinforcing shall be located at center of topping except in shaded areas which require draped mesh. SLOT VENTS Length = 5/8 (Type 0.6CSV,.0CSV, &.CSV) VENTING NON-COMPOSITE DECK 0.6C,.0C, &.C do not include slot vents in the bottom flute. Check with plant for availability of sidelap vents 0.6CSV,.0CSV, &.CSV are the types of deck that should be specified if slot vents in the bottom flute are required. Check with plant for availability of deck types 6 AUG 08

37 REINFORCED CONCRETE SLAB ALLOWABLE LOADS FOR 0.6C DECK Slab Depth (t=.50).5 (t=.00) (t=.50).5 (t=.00) 4 (t=.50) 4.5 (t=4.00) 5 (t=4.50) Reinforcement Superimposed Uniform Load (psf) -- Span Condition Clear Span (ft-in.) WWF A s x6-W.xW x6-W.9xW x6-W4.0xW x6-W.9xW x6-W4.0xW x4-W.9xW x6-W.9xW x6-W4.0xW x4-W.9xW x6-W4.0xW x4-W.9xW x4-W4.0xW x6-W4.0xW x4-W.9xW x4-W4.0xW x4-W.9xW x4-W4.0xW o.c x4-W4.0xW o.c o.c REINFORCED CONCRETE SLAB ALLOWABLE LOADS FOR.0C DECK Slab Depth.5 (t=.50) (t=.00).5 (t=.5) 4 (t=.00) 4.5 (t=.50) 5 (t=4.00) 5.5 (t=4.50) Reinforcement Superimposed Uniform Load (psf) -- Span Condition Clear Span (ft-in.) WWF A s x6-W.xW x6-W.9xW x6-W4.0xW x6-W.9xW x6-W4.0xW x4-W4.0xW x6-W.9xW x6-W4.0xW x4-W4.0xW x6-W4.0xW x4-W.9xW x4-W4.0xW x6-W4.0xW x4-W.9xW x4-W4.0xW x4-W.9xW x4-W4.0xW " o.c x4-W4.0xW " o.c " o.c See page 6 for table footnotes. NON-COMPOSITE AUG 08 7

38 NON-COMPOSITE REINFORCED CONCRETE SLAB ALLOWABLE LOADS FOR.C DECK Slab Depth. (t=.00).8 (t=.50) 4. (t=.00) 4.8 (t=.50) 5. (t=4.00) 5.8 (t=4.50) 6. (t=5.00) REINFORCED CONCRETE SLAB ALLOWABLE LOADS FOR.5C DECK Slab Depth.5 (t=.00) 4.0 (t=.50) 4.5 (t=.00) 5.0 (t=.50) 5.5 (t=4.00) 6.0 (t=4.50) 6.5 (t=5.00) Reinforcement Reinforcement Superimposed Uniform Load (psf) -- Span Condition Clear Span (ft-in.) WWF A s x6-W.9xW x6-W4.0xW x4-W.9xW x6-W.9xW x6-W4.0xW x4-W.9xW Superimposed Uniform Load (psf) -- Span Condition Clear Span (ft-in.) WWF A s x6-W.9xW x6-W4.0xW x4-W.9xW x6-W.9xW x6-W4.0xW x4-W.9xW x6-W4.0xW x4-W.9xW x4-W4.0xW x6-W4.0xW x4-W.9xW x4-W4.0xW x4-W.9xW x4-W4.0xW " o.c x4-W4.0xW " o.c " o.c x4-W4.0xW " o.c " o.c x6-W4.0xW x4-W.9xW x4-W4.0xW x6-W4.0xW x4-W.9xW x4-W4.0xW x4-W.9xW x4-W4.0xW " o.c x4-W4.0xW " o.c " o.c x4-W4.0xW " o.c " o.c See page 6 for table footnotes. 8 AUG 08

39 REINFORCED CONCRETE SLAB ALLOWABLE LOADS FOR C DECK Slab Depth 4.5 (t=.50) 5.0 (t=.00) 5.5 (t=.50) 6.0 (t=4.00) 6.5 (t=4.50) 7.0 (t=5.00) 7.5 (t=5.50) REINFORCED CONCRETE SLAB ALLOWABLE LOADS FOR C DECK Slab Depth 5.0 (t=.00) 5.5 (t=.50) 6.0 (t=.00) 6.5 (t=.50) 7.0 (t=4.00) 7.5 (t=4.50) 8.0 (t=5.00) Reinforcement Reinforcement Superimposed Uniform Load (psf) -- Span Condition Clear Span (ft-in.) WWF A s x6-W.9xW x6-W4.0xW x4-W.9xW x6-W.9xW x6-W4.0xW x4-W4.0xW Superimposed Uniform Load (psf) -- Span Condition Clear Span (ft-in.) WWF A s x6-W.9xW x6-W4.0xW x4-W.9xW x6-W.9xW x6-W4.0xW x4-W.9xW x6-W4.0xW x4-W.9xW x4-W4.0xW x4-W.9xW x4-W4.0xW " o.c x4-W4.0xW " o.c " o.c x4-W4.0xW " o.c " o.c x4-W4.0xW " o.c " o.c x6-W4.0xW x4-W.9xW x4-W4.0xW x6-W4.0xW x4-W.9xW x4-W4.0xW x4-W.9xW x4-W4.0xW " o.c x4-W4.0xW " o.c " o.c x4-W4.0xW " o.c " o.c See page 6 for table footnotes. NON-COMPOSITE AUG 08 9

40 NON-COMPOSITE DECK FIRE RESISTANCE RATINGS Restrained Assembly Rating Type of Protection Concrete Thickness & Type () U.L. Design No. (,) Type of Form Unrestrained Beam Rating NON-COMPOSITE Hr. / Hr. Hr. Hr. Exposed Grid / NW G C,.0C,.C,.5C,, Hr. Cementitious Sprayed Fiber Exposed Grid / NW&LW G70 0.6C,.0C,.C,.5C,.5,, Hr. G C,.0C,.C,.5C,.5, Hr. /4 NW&LW G70 0.6C,.0C,.C,.5C,.5, Hr. / NW&LW G80 0.6C,.0C,.C,.5C,.5, Hr. /4 NW&LW G80 0.6C,.0C,.C,.5C,.5, Hr. NW G C,.0C,.C,.5C.5,, Hr. / NW G C,.0C,.C,.5C.5, Hr. G C,.0C,.C,.5C.5, Hr. NW G + 0.6C,.0C,.C,.5C.5,, Hr. Gypsum Board NW&LW G C,.0C,.C,.5C Cementitious Sprayed Fiber Exposed Grid Gypsum Board Cementitious Sprayed Fiber Exposed Grid / NW&LW G70 0.6C,.0C,.C,.5C,.5,, Hr. G C,.0C,.C,.5C,.5, Hr. /4 NW&LW G70 0.6C,.0C,.C,.5C,.5, Hr. / NW&LW G80 0.6C,.0C,.C,.5C,.5, Hr. /4 NW&LW G80 0.6C,.0C,.C,.5C,.5, Hr. / NW G C,.0C,.C,.5C Hr. G C,.0C,.C,.5C.5, Hr. G C,.0C,.C,.5C.5,, Hr. G C,.0C,.C,.5C.5, Hr. G C,.0C,.C,.5C,, Hr. NW G + 0.6C,.0C,.C,.5C.5,, Hr. NW G C,.0C,.C,.5C / NW&LW G C,.0C,.C,.5C, Hr. / NW / NW&LW G C,.0C,.C,.5C Hr. G C,.0C,.C,.5C Hr. G70 0.6C,.0C,.C,.5C,.5,, Hr. G C,.0C,.C,.5C,.5, Hr. /4 NW&LW G70 0.6C,.0C,.C,.5C,.5, Hr. / NW&LW G80 0.6C,.0C,.C,.5C,.5, Hr. /4 NW&LW G80 0.6C,.0C,.C,.5C,.5, Hr. /4 NW G C,.0C,.C,.5C.5,, Hr. / NW G + 0.6C,.0C,.C,.5C.5,, Hr. G C,.0C,.C,.5C,, Hr. Gypsum Board /4 NW&LW G C,.0C,.C,.5C Hr. Cementitious /4 NW&LW G70 0.6C,.0C,.C,.5C,.5,, Hr. G C,.0C,.C,.5C,.5, Hr. Sprayed Fiber /4 NW&LW G80 0.6C,.0C,.C,.5C,.5, Hr. Notes:. Concrete thickness is thickness of slab above deck, in.. Refer to the U.L. Fire Resistance Directory for the necessary construction details.. finish shall be galvanized unless noted otherwise. + Denotes deck finish is not critical when used in G0--, G-- & G5-- Series designs. finish shall be galvanized or painted. 40 AUG 08

41 NON-COMPOSITE & COMPOSITE FLOOR DECK CONSTRUCTION LOADING DIAGRAMS PER ANSI/SDI C-0 COMPOSITE NON-COMPOSITE Note: Slab weight used in shoring calculations includes an allowance for deck deflection between supports: psf for NW concrete and psf for LW concrete. AUG 08 4

42 WEB CRIPPLING DESIGN EXAMPLE GIVEN: VLI deck with a total slab depth of 6 / of normal weight concrete has a span of 7-7. The end bearing length available is / and the interior bearing length available is 5. From the construction span tables (excerpt below), VLI with this slab depth can span a 8-9 in the simple span condition, but since gauge bearing length varies, web crippling must be checked. CHECK FOR BEARING DESIGN CONDITION: The following checks are performed in accordance with ANSI/SDI C-0 Standard for Composite Steel Floor -Slabs. (N = 9.5) NORMAL WEIGHT CONCRETE (45 PCF) TOTAL SLAB DEPTH DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 7'-0 7'-6 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0 '-6 '-0 '-6 4'-0 VLI 8'-9 8'-6 9' (t=.50) 6 psf VLI0 0'-4 '-0 ' VLI9 '- '-4 ' VLI8 '-8 '-5 ' NON-COMPOSITE VLI6 '-4 '-6 4' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for 9 to 6 gage. Minimum end bearing varies from.5 to.5 for and 0 gage, depending on slab thickness. Minimum interior bearing length of for 6 gage. Minimum interior bearing varies from to 6.5 for 8 to gage, depending on gage and slab thickness. VLI Span: 7.58 ft R a-ext : 49 plf R a-int : 844 plf Single Span W: 65. psf W: 0 psf P: 50 plf P ext = 97 plf <= R a-ext okay COMPOSITE Double Span Triple Span P ext = plf <= R a-ext okay P ext = 5 plf <= R a-ext okay P ext = 4 plf <= R a-ext okay P int = 767 plf <= R a-int okay P int = 807 plf <= R a-int okay P ext = 47 plf <= R a-ext okay P ext = 58 plf <= R a-ext okay P int = 69 plf <= R a-int okay W = W conc + W deck + psf (NW) or psf (LW) P int = 70 plf <= R a-int okay Therefore, the deck is satisfactory for the project details noted above. 4 AUG 08

43 NON-COMPOSITE & COMPOSITE DECK WEB CRIPPLING.5C/.5VLI/.5VLR Gauge Reaction Type Allowable Reaction, (lbs/ft) One Flange Loading Bearing Length (in.) Exterior Interior Exterior Interior Exterior Interior Exterior Interior Exterior Interior C/VLI Gauge C/VLI Gauge Reaction Type Reaction Type Allowable Reaction, (lbs/ft) One Flange Loading Bearing Length (in.) Exterior Interior Exterior Interior Exterior Interior Exterior Interior Exterior Interior Allowable Reaction, (lbs/ft) One Flange Loading Bearing Length (in.) Exterior Interior Exterior Interior Exterior Interior Exterior Interior Exterior Interior NON-COMPOSITE COMPOSITE AUG 08 4

44 COMPOSITE NON-COMPOSITE NON-COMPOSITE & COMPOSITE FLOOR DECK SDI POUR STOP SELECTION TABLE PER ANSI/SDI NC.0 ATTACHMENT NC AND C-0 44 AUG 08

45 NON-COMPOSITE & COMPOSITE DECK DETAILS Hanger Tab Max. Load 60 lbs. per Tab # Wire Minimum COMPOSITE NON-COMPOSITE AUG 08 45

46 .5VL /.5VLI COMPOSITE DECK SECTION PROPERTIES Gauge Design Thickness Weight Section Properties Ip S p I n S n (in.) (psf) (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) (lbs/ft) (ksi) V a F y (N = 9.5) NORMAL WEIGHT CONCRETE (45 PCF) TOTAL SLAB DEPTH DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 5'-0 5'-6 6'-0 6'-6 7'-0 7'-6 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0.5VL 6'-4 7'-5 7' (t=.00) psf.5vl0 7'-7 8'-0 9' VL9 8'- 9'-0 0' VL8 8'-7 0'-6 0' VL6 9'-5 0'-5 0' VL 6'-0 7'-0 7' (t=.50) 9 psf.5vl0 7'- 8'-5 8' VL9 7'-8 9'-4 9' VL8 8'- 9'- 0' VL6 9'-0 9'- 0' VL 5'-9 6'-9 6' (t=.00) 45 psf.5vl0 6'-0 8'-0 8' VL9 7'-4 8'- 9' VL8 7'-9 9'-6 9' COMPOSITE 5.00 (t=.50) 5 psf 5.50 (t=4.00) 57 psf 6.00 (t=4.50) 6 psf.5vl6 8'-7 9'-6 9' VL 5'-6 6'-6 6' VL0 6'-7 7'-8 7' VL9 7'- 8'-6 8' VL8 7'-6 9'- 9' VL6 8'- 9'- 9' VL 5'-4 6'- 6' VL0 6'-4 7'-5 7' VL9 6'-0 8'- 8' VL8 7'- 8'-9 9' VL6 7'-0 8'-9 9' VL 5'- 6'-0 6' VL0 6'- 7'- 7' VL9 6'-7 7'- 8' VL8 7'-0 8'-5 8' VL6 7'-7 8'-5 8' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for to 6 gage. Minimum interior bearing length of for to 6 gage.. Always contact Vulcraft when using loads in excess of 00 psf. Such loads often result from concentrated, dynamic or long term load cases for which reductions due to bond breakage, concrete creep etc. should be evaluated.. All fire rated assemblies are subject to an upper live load limit of 50 psf. 46 AUG 08

47 .5VL /.5VLI COMPOSITE DECK DIMENSIONS SLAB INFORMATION Total Slab Depth Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) Recommended Welded Wire Fabric / x6 - W.4xW x6 - W.4xW.4 4 / x6 - W.4xW.4 4 / x6 - W.4xW x6 - W.xW. 5 / x6 - W.xW. 5 / x6 - W.xW x6 - W.xW. *Volumes and weights do not include allowance for deflection. (N = 4.5) LIGHT WEIGHT CONCRETE (0 PCF) TOTAL SLAB DEPTH DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 5'-0 5'-6 6'-0 6'-6 7'-0 7'-6 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0.5VL 6'-0 8'-0 8' (t=.00) 5 psf.5vl0 8'- 9'-8 9' VL9 8'-0 0'-8 ' VL8 9'-4 '-4 ' VL6 0'- '-4 ' VL 6'-6 7'-8 7' (t=.50) 0 psf.5vl0 7'-0 9'- 9' VL9 8'-5 0'- 0' VL8 8'- 0'-0 ' VL6 9'-9 0'-0 ' VL 6'- 7'-4 7' (t=.00) 5 psf.5vl0 7'-6 8'-0 8' VL9 8'- 9'-9 0' VL8 8'-6 0'-5 0' (t=.5) 7 psf 5.00 (t=.5) 9 psf 5.75 (t=4.5) 46 psf.5vl6 9'-4 0'-5 0' VL 6'- 7'- 7' VL0 7'-4 8'-8 8' VL9 7'- 9'-7 9' VL8 8'-4 0'- 0' VL6 9'- 0'- 0' VL 6'-0 7'- 7' VL0 7'- 8'-6 8' VL9 7'-9 9'-5 9' VL8 8'- 0'-0 0' VL6 9'-0 0'-0 0' VL 5'-9 6'-9 6' VL0 6'-0 8'-0 8' VL9 7'-4 8'- 9' VL8 7'-9 9'-6 9' COMPOSITE.5VL6 8'-6 9'-6 9' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for to 6 gage. Minimum interior bearing length of for to 6 gage.. Always contact Vulcraft when using loads in excess of 00 psf. Such loads often result from concentrated, dynamic or long term load cases for which reductions due to bond breakage, concrete creep etc. should be evaluated.. All fire rated assemblies are subject to an upper live load limit of 50 psf. AUG 08 47

48 .5VLR COMPOSITE DECK SECTION PROPERTIES Gauge Design Thickness Weight Section Properties Ip S p I n S n (in.) (psf) (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) (lbs/ft) (ksi) V a F y (N = 9.5) NORMAL WEIGHT CONCRETE (45 PCF) TOTAL SLAB DEPTH DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 5'-0 5'-6 6'-0 6'-6 7'-0 7'-6 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0.5VLR 6'-4 7'-4 7' (t=.00) 8 psf.5vlr0 7'-5 8'-5 8' VLR9 8'- 9'- 9' VLR8 8'-5 9'-9 0' VLR6 9'-0 9'- 0' VLR 6'-0 7'-0 7' (t=.50) 44 psf.5vlr0 7'- 8'-0 8' VLR9 7'-8 8'-8 9' VLR8 8'-0 9'-4 9' VLR6 8'-8 9'-6 9' VLR 5'-9 6'-8 6' (t=.00) 50 psf.5vlr0 6'-9 7'-8 7' VLR9 7'-5 8'-4 8' VLR8 7'-9 8'- 9' COMPOSITE 5.00 (t=.50) 56 psf 5.50 (t=4.00) 6 psf 6.00 (t=4.50) 68 psf.5vlr6 8'-4 9'- 9' VLR 5'-7 6'-5 6' VLR0 6'-6 7'-4 7' VLR9 7'- 8'-0 8' VLR8 7'-5 8'-7 8' VLR6 8'-0 8'-9 9' VLR 5'-5 6'- 6' VLR0 6'- 7'- 7' VLR9 6'- 7'-9 8' VLR8 7'- 8'- 8' VLR6 7'-8 8'-5 8' VLR 5'- 6'-0 6' VLR0 6'- 6'-0 7' VLR9 6'-9 7'-5 7' VLR8 7'-0 8'-0 8' VLR6 7'-5 8'- 8' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for to 6 gage. Minimum interior bearing length of for to 6 gage.. Always contact Vulcraft when using loads in excess of 00 psf. Such loads often result from concentrated, dynamic or long term load cases for which reductions due to bond breakage, concrete creep etc. should be evaluated.. All fire rated assemblies are subject to an upper live load limit of 50 psf. 48 AUG 08

49 .5VLR COMPOSITE DECK DIMENSIONS SLAB INFORMATION Total Slab Depth Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) Recommended Welded Wire Fabric / x6 - W.4xW x6 - W.4xW.4 4 /. 0. 6x6 - W.4xW.4 4 / x6 - W.4xW x6 - W.xW. 5 / x6 - W.xW. 5 / x6 - W.xW x6 - W.xW. *Volumes and weights do not include allowance for deflection. (N = 4.5) LIGHT WEIGHT CONCRETE (0 PCF) TOTAL SLAB DEPTH DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 5'-0 5'-6 6'-0 6'-6 7'-0 7'-6 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0.5VLR 6'-0 8'-0 8' (t=.00) 9 psf.5vlr0 8'- 9'- 9' VLR9 8'-0 9'- 0' VLR8 9'- 0'-8 ' VLR6 9'-0 0'-0 ' VLR 6'-7 7'-8 7' (t=.50) 4 psf.5vlr0 7'-9 8'-9 9' VLR9 8'-5 9'-6 9' VLR8 8'-9 0'- 0' VLR6 9'-5 0'-4 0' VLR 6'-4 7'-4 7' (t=.00) 9 psf.5vlr0 7'-5 8'-5 8' VLR9 8'- 9'- 9' VLR8 8'-5 9'-0 0' (t=.5) 4 psf 5.00 (t=.5) 4 psf 5.75 (t=4.5) 50 psf.5vlr6 9'- 9'- 0' VLR 6'- 7'- 7' VLR0 7'-4 8'- 8' VLR9 7'- 9'-0 9' VLR8 8'- 9'-7 9' VLR6 8'- 9'-9 0' VLR 6'- 7'- 7' VLR0 7'- 8'- 8' VLR9 7'-0 8'-0 9' VLR8 8'- 9'-5 9' VLR6 8'-9 9'-7 9' VLR 5'-0 6'-9 6' VLR0 6'-0 7'-9 8' VLR9 7'-6 8'-5 8' VLR8 7'-9 9'-0 9' COMPOSITE.5VLR6 8'-4 9'- 9' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for to 6 gage. Minimum interior bearing length of for to 6 gage.. Always contact Vulcraft when using loads in excess of 00 psf. Such loads often result from concentrated, dynamic or long term load cases for which reductions due to bond breakage, concrete creep etc. should be evaluated.. All fire rated assemblies are subject to an upper live load limit of 50 psf. AUG 08 49

50 VLI COMPOSITE DECK SECTION PROPERTIES Gauge Design Thickness Weight Section Properties Ip S p I n S n (in.) (psf) (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) (lbs/ft) (ksi) V a F y (N = 9.5) NORMAL WEIGHT CONCRETE (45 PCF) TOTAL SLAB DEPTH DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 5'-6 6'-0 6'-6 7'-0 7'-6 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0 '-6 VLI 7'-0 9'-0 9' (t=.00) 9 psf VLI0 9'-5 0'-5 0' VLI9 0'- '-7 ' VLI8 0'-6 '-8 ' VLI6 '- '-0 ' VLI 7'-6 8'-7 8' (t=.50) 45 psf VLI0 9'-0 9'- 0' VLI9 9'-8 '- ' VLI8 0'- '- ' VLI6 0'-0 '- ' VLI 7'- 8'- 8' (t=.00) 5 psf VLI0 8'-7 9'-6 9' VLI9 9'- 0'-7 0' VLI8 9'-8 '-6 ' COMPOSITE 5.50 (t=.50) 57 psf 6.00 (t=4.00) 6 psf 6.50 (t=4.50) 69 psf VLI6 0'-5 '-9 ' VLI 6'-0 7'- 8' VLI0 8'- 9'- 9' VLI9 8'- 0'- 0' VLI8 9'-4 '- ' VLI6 0'-0 '- ' VLI 6'-7 7'-7 7' VLI0 7'- 8'-9 9' VLI9 8'-8 9'-0 0' VLI8 9'-0 0'-8 ' VLI6 9'-9 0'-0 ' VLI 6'-5 7'-4 7' VLI0 7'-8 8'-6 8' VLI9 8'-5 9'-6 9' VLI8 8'-9 0'-4 0' VLI6 9'-5 0'-6 0' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for 0 to 6 gage. Minimum end bearing varies from.5 to.75 for gage, depending on slab thickness. Minimum interior bearing length of for 9 to 6 gage. Minimum interior bearing varies from.5 to 5.5 for 0 and gage, depending on gage and slab thickness.. Always contact Vulcraft when using loads in excess of 00 psf. Such loads often result from concentrated, dynamic or long term load cases for which reductions due to bond breakage, concrete creep etc. should be evaluated.. All fire rated assemblies are subject to an upper live load limit of 50 psf. 50 AUG 08

51 VLI COMPOSITE DECK DIMENSIONS SLAB INFORMATION Total Slab Depth Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) Recommended Welded Wire Fabric x6 - W.4xW.4 4 / x6 - W.4xW x6 - W.4xW.4 5 / x6 - W.4xW.4 5 / x6 - W.xW x6 - W.xW. 6 / x6 - W.xW. 6 / x6 - W.xW. *Volumes and weights do not include allowance for deflection. (N = 4.5) LIGHT WEIGHT CONCRETE (0 PCF) TOTAL SLAB DEPTH 4.00 (t=.00) 0 psf 4.50 (t=.50) 5 psf 5.00 (t=.00) 9 psf 5.5 (t=.5) 4 psf 5.50 (t=.5) 44 psf 6.5 (t=4.5) 5 psf DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 6'-0 6'-6 7'-0 7'-6 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0 '-6 '-0 VLI 8'-7 9'-0 0' VLI0 0'-4 '-4 ' VLI9 '-0 '-8 ' VLI8 '-5 '-9 ' VLI6 '- 4'-0 4' VLI 8'- 9'-5 9' VLI0 9'- 0'- ' VLI9 0'-7 '- ' VLI8 '-0 '- ' VLI6 '-8 '-5 ' VLI 7'-0 9'- 9' VLI0 9'-6 0'-5 0' VLI9 0'- '-8 ' VLI8 0'-7 '-8 ' VLI6 '-4 '- ' VLI 7'-9 8'- 9' VLI0 9'- 0'- 0' VLI9 9'- '-5 ' VLI8 0'-5 '-5 ' VLI6 '- '-8 ' VLI 7'-7 8'-9 8' VLI0 9'- 0'- 0' VLI9 9'-9 '- ' VLI8 0'- '- ' VLI6 '-0 '-5 ' VLI 7'- 8'- 8' VLI0 8'-8 9'-7 9' VLI9 9'-4 0'-8 ' VLI8 9'-9 '-7 ' VLI6 0'-6 '-0 ' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for to 6 gage. Minimum interior bearing length of for 0 to 6 gage. Minimum interior bearing varies from.5 to.65 for gage, depending on slab thickness.. Always contact Vulcraft when using loads in excess of 00 psf. Such loads often result from concentrated, dynamic or long term load cases for which reductions due to bond breakage, concrete creep etc. should be evaluated.. All fire rated assemblies are subject to an upper live load limit of 50 psf. COMPOSITE AUG 08 5

52 VLI COMPOSITE DECK SECTION PROPERTIES Gauge Design Thickness Weight Section Properties Ip S p I n S n (in.) (psf) (in 4 /ft) (in /ft) (in 4 /ft) (in /ft) (lbs/ft) (ksi) V a F y (N = 9.5) NORMAL WEIGHT CONCRETE (45 PCF) TOTAL SLAB DEPTH DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 7'-0 7'-6 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0 '-6 '-0 '-6 4'-0 VLI 0'-0 0'-9 ' (t=.00) 45 psf VLI0 '-8 '-5 ' VLI9 '- '- 4' VLI8 '-7 5'- 4' VLI6 '-4 5'- 5' VLI 9'-6 9'- 0' (t=.50) 5 psf VLI0 '- '- ' VLI9 '-0 '-4 ' VLI8 '- 4'-6 4' VLI6 '- 4'-7 5' VLI 9'- 9'- 0' (t=.00) 57 psf VLI0 0'-9 '-5 ' VLI9 '-7 '-9 ' VLI8 '- '- 4' COMPOSITE 6.50 (t=.50) 6 psf 7.00 (t=4.00) 69 psf 7.50 (t=4.50) 75 psf VLI6 '-7 4'-0 4' VLI 8'-9 8'-6 9' VLI0 0'-4 '-0 ' VLI9 '- '-4 ' VLI8 '-8 '-5 ' VLI6 '-4 '-6 4' VLI 8'-6 7'- 9' VLI0 0'-0 0'-8 ' VLI9 '-0 '- ' VLI8 '-5 '-0 ' VLI6 '- '- ' VLI 8'- 7'-5 8' VLI0 9'-8 0'- 0' VLI9 0'-8 '-6 ' VLI8 '- '-7 ' VLI6 '-0 '-8 ' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for 9 to 6 gage. Minimum end bearing varies from.5 to.5 for and 0 gage, depending on slab thickness. Minimum interior bearing length of for 6 gage. Minimum interior bearing varies from to 6.5 for 8 to gage, depending on gage and slab thickness.. Always contact Vulcraft when using loads in excess of 00 psf. Such loads often result from concentrated, dynamic or long term load cases for which reductions due to bond breakage, concrete creep etc. should be evaluated.. All fire rated assemblies are subject to an upper live load limit of 50 psf. 5 AUG 08

53 VLI COMPOSITE DECK DIMENSIONS SLAB INFORMATION Total Slab Depth Theo. Concrete Volume (in.) (Yd /00 ft ) (ft /ft ) Recommended Welded Wire Fabric x6 - W.4xW.4 5 /. 0. 6x6 - W.4xW x6 - W.4xW.4 6 / x6 - W.4xW.4 6 / x6 - W.xW x6 - W.xW. 7 / x6 - W.xW. 7 / x6 - W.xW. *Volumes and weights do not include allowance for deflection. (N = 4.5) LIGHT WEIGHT CONCRETE (0 PCF) TOTAL SLAB DEPTH DECK TYPE SDI Max. Unshored Clear Span SPAN SPAN SPAN Superimposed Live Load ( PSF) Clear Span (ft-in.) 8'-0 8'-6 9'-0 9'-6 0'-0 0'-6 '-0 '-6 '-0 '-6 '-0 '-6 4'-0 4'-6 5'-0 VLI '-0 '-0 ' (t=.00) 5 psf VLI0 '-6 '-8 4' VLI9 '- 5'- 5' VLI8 '-6 6'-7 5' VLI6 4'- 6'-8 6' VLI 0'-7 '-4 ' (t=.50) 9 psf VLI0 '- '- ' VLI9 '-8 4'-8 4' VLI8 '- 5'- 5' VLI6 '-0 6'-0 6' VLI 0'- 0'- ' (t=.00) 44 psf VLI0 '-0 '-8 ' VLI9 '-4 4'- 4' VLI8 '-9 5'-4 4' (t=.5) 46 psf 6.50 (t=.5) 48 psf 7.5 (t=4.5) 55 psf VLI6 '-6 5'-6 5' VLI 9'- 0'-8 ' VLI0 '-8 '-5 ' VLI9 '- '-0 4' VLI8 '-7 5'- 4' VLI6 '-4 5'- 5' VLI 9'-9 0'-5 0' VLI0 '-6 '- ' VLI9 '- '-8 4' VLI8 '-5 4'-0 4' VLI6 '- 4'- 5' VLI 9'-4 9'-6 0' VLI0 '-0 '-8 ' VLI9 '-8 '-0 ' VLI8 '- 4'- 4' COMPOSITE VLI6 '-9 4'- 4' Notes:. Maximum unshored spans do not consider web crippling. Required bearing should be determined based on allowable reactions on page 4 or with the Vulcraft Unshored Span Calculator available at The following conditions are required to meet the maximum unshored spans shown: Minimum exterior bearing length of.5 for 0 to 6 gage. Minimum end bearing varies from.5 to.5 for gage, depending on slab thickness. Minimum interior bearing length of for 8 and 6 gage. Minimum end bearing varies from to 6.5 for to 9 gage, depending on gage and slab thickness.. Always contact Vulcraft when using loads in excess of 00 psf. Such loads often result from concentrated, dynamic or long term load cases for which reductions due to bond breakage, concrete creep etc. should be evaluated.. All fire rated assemblies are subject to an upper live load limit of 50 psf. AUG 08 5

54 COMPOSITE DECK FIRE RESISTANCE RATINGS COMPOSITE Restrained Assembly Rating Type of Protection Concrete Thickness & Type () /4 Hr. Unprotected / LW Hr. / Hr. U.L. Design No. (,,4) Classified Type Fluted Cellular (5) Unrestrained Beam Rating D94 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. Exposed Grid / NW D6 +.5VL,.5VLI,VLI,VLI VLP, VLP, Hr. Cementitious Sprayed Fiber Unprotected NW&LW D74 * VLI,VLI VLP, VLP,.5,, Hr. / NW&LW D70 *.5VLI,VLI,VLI.5VLP, VLP, VLP.5 Hr. D7 * VLI VLP Hr. D7 * VLI,VLI VLP, VLP,.5, Hr. D79 *.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,,,4 Hr. D759.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. NW&LW D859 * VLI,VLI VLP, VLP,.5,, Hr. / NW&LW / LW / NW D8 *.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D847 * VLI,VLI VLP,.5, Hr. D858 * VLI,VLI VLP, VLP,.5,,4 Hr. D87 * VLI,VLI VLP, VLP,.5,, Hr. D90 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D94 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D98 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D99 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D90 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D98 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D99 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. Gypsum Board / NW D50 *.5VL,.5VLI,VLI,VLI VLP, VLP.5, Hr. Cementitious Sprayed Fiber Unprotected NW&LW D74 * VLI,VLI VLP, VLP,.5,, Hr. / NW&LW D70 *.5VLI,VLI,VLI.5VLP, VLP, VLP.5 Hr. D7 * VLI VLP Hr. D7 * VLI,VLI VLP, VLP,.5, Hr. D79 *.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,,,4 Hr. D759.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. NW&LW D859 * VLI,VLI VLP, VLP,.5,, Hr. / NW&LW LW 4 NW D8 *.5VLI,VLI,VLI VLP,.5,, Hr. D847 * VLI,VLI VLP,.5, Hr. D858 * VLI,VLI VLP, VLP,.5,,4 Hr. D87 * VLI,VLI VLP, VLP,.5,, Hr. D90 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D99 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D90 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D98 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D99 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. Notes:. Concrete thickness is thickness of slab above deck, in.. Refer to the U.L. Fire Resistance Directory for the necessary construction details.. Cellular deck finish shall be galvanized. 4. Fluted deck finish shall be galvanized unless noted otherwise. + Denotes fluted deck finish is not critical when used in D-- & D5-- Series designs. finish shall be galvanized or phosphatized/painted. * Fluted deck finish is critical for fire resistance. Fluted deck finish shall be galvanized or phosphatized/painted. This paint is a special type of paint and is compatible with the spray-applied fire protection and is U.L. approved for use in the denoted D7-- & D8-- Series designs. # Denotes fluted deck finish is not critical for fire resistance. Fluted deck finish shall be galvanized or phosphatized/painted. 5. Vulcraft cellular deck units are approved by U.L. for use as electrical raceways under U.L Standard AUG 08

55 COMPOSITE DECK FIRE RESISTANCE RATINGS Restrained Assembly Rating Hr. Type of Protection Exposed Grid / NW D6 +.5VL,.5VLI,VLI,VLI VLP, VLP, Hr. Gypsum Board / NW D50 +.5VL,.5VLI,VLI,VLI VLP, VLP.5, Hr. Cementitious Sprayed Fiber Concrete Thickness & Type () NW&LW D74 * VLI,VLI VLP, VLP,.5,, Hr. / LW / NW&LW / NW U.L. Design No. (,,4) Classified Type Fluted Cellular (5) Unrestrained Beam Rating D746 *.5VLI,.5,, Hr. D75 *.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D70 *.5VLI,VLI,VLI.5VLP, VLP, VLP.5 Hr. D7 * VLI VLP Hr. D76 *.5VLI,VLI,VLI VLP, VLP.5, Hr. D7 * VLI,VLI VLP, VLP,.5, Hr. D79 *.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,,,4 Hr. D745 * VLI,VLI,.5,, Hr. D750 *.5VLI,VLI,VLI.5, Hr. D755.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D759.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D760 * VLI,VLI,.5,,,4 Hr. D70 * VLI,VLI VLP, VLP.5, Hr. D74 *.5VLI,VLI,VLI,.5 Hr. NW&LW D859 * VLI,VLI VLP, VLP,.5,, Hr. / NW&LW D8 * VLI,VLI VLP, VLP Hr. D85 *.5VLI,VLI,VLI VLP, VLP,.5, Hr. D8 * VLI,VLI VLP, VLP,.5, Hr. D8 *.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D8 *.5VLI,VLI,VLI VLP, VLP.5 Hr. D847 * VLI,VLI VLP,.5, Hr. D858 * VLI,VLI VLP, VLP,.5,,4 Hr. D86 * VLI,VLI,.5 Hr. D87 * VLI,VLI VLP, VLP,.5,, Hr. / LW D86 * VLI,VLI Hr. / NW D864 * VLI VLP.5 Hr. /4 LW D860 * VLI,VLI,.5, Hr. /4 LW 4 / NW D86 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5, Hr. D840 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D90 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D907 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP, Hr. D9 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D98 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D99 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D90 # VLI,VLI VLP, VLP.5 Hr. D90 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D98 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D99 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. COMPOSITE See Page 54 for notes. AUG 08 55

56 COMPOSITE DECK FIRE RESISTANCE RATINGS COMPOSITE Restrained Assembly Rating Hr. 4 Hr. See Page 54 for notes. Type of Protection Exposed Grid /4 NW D6 +.5VL,.5VLI,VLI,VLI VLP, VLP, Hr. Cementitious Sprayed Fiber Unprotected Cementitious Sprayed Fiber Concrete Thickness & Type () NW&LW D74 * VLI,VLI VLP, VLP,.5,, Hr. / LW D746 *.5VLI,.5,, Hr. / NW&LW D70 *.5VLI,VLI,VLI.5VLP, VLP, VLP.5 Hr. D708 *.5VLI,VLI,VLI.5VLP, VLP, VLP.5, Hr. D79 *.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,,,4 Hr. D755.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D759.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D760 * VLI,VLI,.5,,,4 Hr. /4 LW D754 *.5VLI,VLI,VLI.5, Hr. /4 NW D74 *.5VLI,VLI,VLI,.5 Hr. NW&LW D859 * VLI,VLI VLP, VLP,.5,, Hr. / NW&LW D86 *.5VLI,VLI,VLI VLP, VLP.5, Hr. D8 * VLI,VLI VLP, VLP,.5, Hr. D8 *.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D8 *.5VLI,VLI,VLI VLP, VLP.5 Hr. D858 VLI,VLI VLP, VLP,.5,,4 Hr. D87 * VLI,VLI VLP, VLP,.5,, Hr. / NW D864 VLI VLP.5 Hr. /4 LW D860 * VLI,VLI,.5, Hr. 4 /6 LW 5 /4 NW / NW&LW D90 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D98 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D99 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D90 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D96 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,, Hr. D98 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D99 #.5VL,.5VLI,VLI,VLI.5VLP, VLP, VLP,.5 Hr. D760 VLI,VLI,.5,,,4 Hr. D79.5VLI,VLI,VLI.5VLP, VLP, VLP,.5,,,4 Hr. /4 LW D754.5VLI,VLI,VLI.5, Hr. / NW&LW U.L. Design No. (,,4) Classified Type Fluted Cellular (5) Unrestrained Beam Rating D858 VLI,VLI VLP, VLP,.5,,4 Hr. /4 LW D860 VLI,VLI,.5, Hr. 56 AUG 08

57 DIAPHRAGM DESIGN Diaphragm design information for Vulcraft roof and floor decks is based on the Steel Institute Diaphragm Design Manual, Third Edition (DDM0) specified by ANSI/SDI RD.0, NC.0 and C-0 in accordance with 05 IBC Section 0. ROOF DECK Historically, published diaphragm design tables for roof deck have been based on diaphragm shear loads only. These historical tables have not considered the condition of wind uplift in conjunction with diaphragm shear due to wind loads. When support fasteners must resist a significant amount of tension load due to wind uplift, the allowable shear strength of those fasteners is reduced. As net wind uplift increases, allowable diaphragm shear capacity decreases. The effects of uplift are currently included in the diaphragm tables in the Vulcraft catalogs for the PunchLok II System and DoveTail. Vulcraft Diaphragm Calculator: Vulcraft is pleased to introduce the Vulcraft Diaphragm Calculator to assist in the determination of diaphragm capacity and stiffness of decks without fill. The Diaphragm Calculator can determine capacity governed by seismic, wind only, or wind in conjunction with uplift. Access the diaphragm calculator at: Diaphragm Design Resources: Additional diaphragm design information for Vulcraft roof decks is available at including: Vulcraft PunchLok II System Catalogs Vulcraft DoveTail Catalogs Legacy Roof Diaphragm Tables DESIGN EXAMPLE The Vulcraft PunchLok II System is used to illustrate the basic issues involved in the determining roof deck diaphragm capacity and stiffness. See page 0 of this catalog for additional information on the PunchLok II System. Design Criteria: The objective is to select the deck system for the roof of a warehouse building. The roof structure is constructed of steel joists with top chord thicknesses from /8 to /6. The joist spacing is 5-0 o.c. The contractor has requested ½ deep PLB deck attached to the supports with power actuated mechanical fasteners. ASD is the basis of design. The design criteria are as follows: Net Wind Uplift Load = 60 psf Required Diaphragm Strength (Seismic) = 55 plf Required Diaphragm Strength (Wind) = 575 plf (MWFRS) Required Diaphragm Stiffness = 60 k/in Diaphragm Capacity and Stiffness: Start by selecting the appropriate power actuated fastener based on the substrate thickness. Consider Hilti X-HSN 4 fasteners for this example. Based on the selected fastener, use the Vulcraft PunchLok II Roof Catalog for Hilti Support Connections (pg 40) to determine the capacity and stiffness of gage.5plb roof deck. DIAPHRAGM AUG 08 57

58 Check Seismic Capacity Start by checking seismic capacity. Type =.5PLB Span = 5-0 Substrate Thickness = /8 and /6 Selected Fastener = Hilti X-HSN 4 Fastener Substrate Range = /8 and /8 OK Support Fastener Attachment Pattern Number of VSC s required per Span = 6/7 = Allowable Diaphragm Shear Strength = 645 plf > 55 plf OK Check Wind Capacity When checking diaphragms for wind, uplift should also be considered. Note that components and cladding pressure is used for deck and fastener uplift checks (outside the scope of this example). MWFRS pressure is used for diaphragm interaction. In this example, the roof has a significant net wind uplift pressure; therefore shear/tension interaction must be checked. Net Wind Uplift Load = 60 psf Support Fastener Attachment Pattern Number of VSC s required per Span = 6/7 = 4 Allowable Diaphragm Shear Strength = 59 plf > 575 plf OK Check Diaphragm Stiffness Since wind requires more PunchLok II System sidelap connections (VSC s) per span, it will be used to verify that the diaphragm meets the stiffness requirements of the project. Diaphragm Stiffness, G = 6 k/in > 60 k/in OK Summarize Design The following design meets the project design requirements: Type =.5PLB Span = 5-0 Substrate Thickness = /8 and /6 Selected Fastener = Hilti X-HSN 4 Fastener Substrate Range = /8 and /8 OK Support Fastener Attachment Pattern = 6/7 Number of VSC s required per Span = 4 DIAPHRAGM Allowable Seismic Diaphragm Shear Strength Allowable Diaphragm Shear Strength with 60 psf Net Wind Uplift Diaphragm Stiffness, G Please note that the parallel attachments must be designed to complete the diaphragm design. Refer to pg 6 of Vulcraft PunchLok II Roof Catalog = 75 plf > 55 plf OK = 59 plf > 575 plf OK = 6 k/in > 60 k/in OK 58 AUG 08

59 VULCRAFT DIAPHRAGM CALCULATOR The online Vulcraft Diaphragm Calculator allows easy determination of unfilled deck diaphragm strength and stiffness. The calculator is based on the Steel Institute Diaphragm Design Manual, Third Edition (DDM0) specified by ANSI/SDI RD.0, NC.0 and C-0 in accordance with 05 IBC Section 0. The Diaphragm Calculator can be accessed at: Use Vulcraft s Diaphragm Calculator because it: Expands scope of published tables by creating customized diaphragm tables using selected fasteners, patterns, and table ranges. Provides detailed calculations for user defined specific conditions. Allows choice of ASD, LRFD, or LSD design. Includes roof deck as well as non-composite and composite decks without fill. Determines seismic diaphragm strength, wind diaphragm strength in combination with uplift, and diaphragm stiffness. Includes PunchLok II system values for applicable profiles DIAPHRAGM To facilitate the determination of diaphragm performance, the Vulcraft Diaphragm Calculator: Simplifies complex wind uplift / shear interaction calculations. Calculates required number of edge fasteners based on selected attachment patterns. Includes welds, screws and PAF support connections. Includes VSC s (PunchLok system), welds, screws, and button punched sidelap connections. Allows definition of sidelap connections by either quantity/span or by spacing. AUG 08 59

3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 STEEL

3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 STEEL 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 STEEL 3NL-32 Used With Sidelap Screws 3NI-32 Used With TSWs or BPs 3PLN-32 Used With PunchLok II System Nominal Dimensions Nested Sidelap 3NL-32 Interlocking

More information

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: 2100 REXFORD ROAD CHARLOTTE, NORTH CAROLINA EVALUATION SUBJECT:

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: 2100 REXFORD ROAD CHARLOTTE, NORTH CAROLINA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 3 658 (56) 699 053 www.icc es.org ESR 1 Reissued 1/01 This report is subject to renewal 1/0. DIVISION: 05 00 00 METALS SECTION:

More information

COMMERCIAL CONSTRUCTION MANUFACTURERS OF CORRUGATED STEEL DECKING PRODUCTS CELLULAR DECK ROOF DECK FLOOR DECK.

COMMERCIAL CONSTRUCTION MANUFACTURERS OF CORRUGATED STEEL DECKING PRODUCTS CELLULAR DECK ROOF DECK FLOOR DECK. DACSinc. COMMERCIAL CONSTRUCTION MANUFACTURERS OF CORRUGATED STEEL DECKING PRODUCTS CELLULAR DECK ROOF DECK FLOOR DECK www.dacsinc.com DACS Products Earn Factory Mutual Approval DACS, Inc. is pleased to

More information

Catalog VF4. Verco s manufacturing facilities are located in Phoenix, Arizona, and the California cities of Fontana and Antioch.

Catalog VF4. Verco s manufacturing facilities are located in Phoenix, Arizona, and the California cities of Fontana and Antioch. This catalog covers Verco Decking, Inc. s FORMLOK composite decks and VERCOR non-composite form decks. It also features the innovative PunchLok System for floor deck applications. By significantly speeding

More information

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi )

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi ) 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2839 Reissued 05/2015 This report is subject to renewal 05/2016. DIVISION: 05 00 00 METALS SECTION:

More information

December 1, Table of Contents. TABLE TOPIC PAGE General TABLE TOPIC PAGE. Roof Decks (continued) (Diaphragm Shear Values)

December 1, Table of Contents. TABLE TOPIC PAGE General TABLE TOPIC PAGE. Roof Decks (continued) (Diaphragm Shear Values) Page 1 of 57 Table of Contents Report ER-78P December 1, 02 TABLE TOPIC PAGE General 1 Allowable Shear Values - Spot or Seam Welds 2 2 Allowable Tension Loads - Hilti Fasteners... 2 3 Allowable Shear and

More information

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER: 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-1735 Reissued 04/2015 This report is subject to renewal 03/2016 DIVISION: 05 00 00 METALS SECTION:

More information

This product is no longer manufactured.

This product is no longer manufactured. s t e e l R O O F d e c k L E G A C Y P R O D U C T This product is no longer manufactured. This product information has been made available to support the retrofit of existing buildings by providing the

More information

GENERAL INFORMATION FEATURES.

GENERAL INFORMATION FEATURES. TECHNICAL GUIDE GENERAL INFORMATION SUPERIOR ENGINEERED JOIST SYSTEMS JoistRite is a specially designed, patented, cold-formed steel section that has one of the highest strength-to-mass ratios of any structural

More information

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015.

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015. ICC-ES Evaluation Report ESR-2408 Reissued August 2014 This report is subject to renewal August 2015. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

ROOF DECK CATALOG VERSION 1.0

ROOF DECK CATALOG VERSION 1.0 ROOF DECK CATALOG VERSION 1.0 ASC Steel Deck is leading the way in innovation with ongoing testing of our profiles. As a result, the printed catalog may not contain/reflect the latest test results and

More information

ESR-1414 Reissued October 1, 2011 This report is subject to renewal in one year.

ESR-1414 Reissued October 1, 2011 This report is subject to renewal in one year. ICC-ES Evaluation Report www.icc-es.org (00) 23-657 (562) 699-053 ESR-11 Reissued October 1, 2011 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION:

More information

DeltaStud - Lightweight Steel Framing

DeltaStud - Lightweight Steel Framing DeltaStud - Lightweight Steel Framing B C H A t P Load Tables for Wind Bearing and Combined Wind & Axial Load Bearing Condition January 2014 Table of Contents Commentary Introduction...3 Product Identification...3

More information

Supreme. Supreme Framing System. Product Catalog IAPMO UNIFORM ER #0313

Supreme. Supreme Framing System. Product Catalog IAPMO UNIFORM ER #0313 Supreme Supreme Framing System Product Catalog IAPMO UNIFORM ER #0313 2507 Table of Contents Certification of Materials 5 LEED Credits 5 Independent Product Certification 5 Code Approvals, Performance

More information

Expanding Your Solutions. Steel Framing and Accessories. ICC ESR and 2015 IBC, IRC

Expanding Your Solutions. Steel Framing and Accessories. ICC ESR and 2015 IBC, IRC Expanding Your Solutions Steel Framing and Accessories ICC ESR-30 20 and 2015 IBC, IRC Effective 1/4/2017 Table of Contents Introduction to CEMCO... 1 Product Identification... 2 3 LEED Certification...

More information

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS REVEAL SERIES ARCHITECTURAL DECK PRODUCTS ROOF AND FLOOR DECK CEILING SYSTEMS Reveal Series is a suite of metal deck systems that utilizes the inherent strength of structural deck and the aesthetic appeal

More information

ESR-1414 Reissued July 2014 This report is subject to renewal October 1, 2015.

ESR-1414 Reissued July 2014 This report is subject to renewal October 1, 2015. ICC-ES Evaluation Report www.icc-es.org (00) 23-6 (62) 699-03 ESR-11 Reissued July 201 This report is subject to renewal October 1, 201. A Subsidiary of the International Code Council DIVISION: 0 00 00

More information

U.S. PATENT NO.: US 7,765,771 TECHNICAL GUIDE SUPERIOR ENGINEERED FLOOR FRAMING SYSTEM

U.S. PATENT NO.: US 7,765,771 TECHNICAL GUIDE SUPERIOR ENGINEERED FLOOR FRAMING SYSTEM U.S. PATENT NO.: US 7,765,771 TECHNICAL GUIDE SUPERIOR ENGINEERED FLOOR FRAMING SYSTEM SUPERIOR ENGINEERED JOIST SYSTEMS JoistRite is a specially designed, patented, cold-formed steel section that has

More information

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15. The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15. Please refer to the publication in its entirety for complete details on this product

More information

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS UNITED STATES

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS UNITED STATES REVEAL SERIES ARCHITECTURAL DECK PRODUCTS UNITED STATES ROOF AND FLOOR DECK CEILING SYSTEMS Reveal Series is a suite of metal deck systems that utilizes the inherent strength of structural deck and the

More information

2.0E ES LVL U.S. Design Manual

2.0E ES LVL U.S. Design Manual I N T E R N A T I O N A L B E A M S 2.0E ES LVL U.S. Design Manual August 2013 2 INTERNATIONAL BEAMS, INC. Our Company At International Beams, Inc. we take pride in providing our customers with premium

More information

2507 (IBC 2006 ONLY) 3054 (IBC 2006 ONLY) Supreme Framing System Product Catalog

2507 (IBC 2006 ONLY) 3054 (IBC 2006 ONLY) Supreme Framing System Product Catalog 12 0 2 / 2009IANT C B I PL COM 2507 (IBC 2006 ONLY) 3054 (IBC 2006 ONLY) R Supreme Framing System Product Catalog Supreme Framing System The Benefits of Supreme Framing System Speak for Themselves What

More information

Originally Issued: 02/03/2014 Revised: 02/24/2017 Valid Through: 02/28/2018

Originally Issued: 02/03/2014 Revised: 02/24/2017 Valid Through: 02/28/2018 Number: 329 Originally Issued: 02/03/2014 Revised: 02/24/2017 Valid Through: 02/28/2018 EVALUATION SUBJECT: COMPOSITE STEEL FLOOR DECK REPORT HOLDER: ASC Steel Deck, A Division of ASC Profiles LLC 2110

More information

Table of Contents. PrimeJoist

Table of Contents. PrimeJoist JamStud Introduction Table of Contents PrimeJoist Introduc on...1 Fire & Sound Tested Assemblies...2 PrimeJoist Design Considera ons...3-4 PrimeJoist Product Profile...5 PrimeJoist Sec on Proper es...6

More information

IBC 2009/2012 COMPLIANT. Supreme Framing System. Product Catalog

IBC 2009/2012 COMPLIANT. Supreme Framing System. Product Catalog IBC 2009/2012 COMPLIANT 2507 Supreme Framing System Product Catalog Supreme Framing System The Benefits of Supreme Framing System Speak for Themselves What is the Supreme Framing System? Supreme Framing

More information

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: ITW BUILDEX

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: ITW BUILDEX 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3270 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 05 00

More information

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS CANADA

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS CANADA REVEAL SERIES ARCHITECTURAL DECK PRODUCTS CANADA ROOF AND FLOOR DECK CEILING SYSTEMS Reveal Series is a suite of metal deck systems that utilizes the inherent strength of structural deck and the aesthetic

More information

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2.

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2. GP Lam LVL Grade Thickness Depth 2.0E 1 3 49, 3 1 29 7 1 49, 9 1 49, 9 1 29, 11 1 49, 11 7 89, 149, 169, 189, 249 (209and 229 by special order) 1.5E 1 3 49 7 1 49, 9 1 49, 9 1 29, 11 1 49, 11 7 89, 149,

More information

WARRANTY AND LIMITATIONS

WARRANTY AND LIMITATIONS 2 GENERAL INFORMATION QUALITY AND SERVICE COUNT Marino\Ware is proud to present this catalog that details our Lightweight Steel Framing Products. For over 70 years, Marino\Ware has been providing their

More information

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2.

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2. GP Lam LVL GP Lam LVL Introduction.....................32 Bearing Details...................34 Handling and Installation..........35 Floor Beams.....................35 Window, Patio Door and Garage Door

More information

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association Maximum Span Tables for Joists and Rafters MSR Lumber for Performance Figure provided courtesy of the American Forest & Paper Association 2 MSRLumber Producers Council Span Tables Purpose and Introduction

More information

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes.

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes. GP Lam LVL Grade 2.0E 1.5E Thickness Depth 13 4!, 31 2! 7 4!, 9 4!, 9 2!, 11 4!, 117 8!, 14!, 16!, 18!, 24! (20!and 22! by special order) 13 4! 7 1 4!, 9 1 4!, 9 1 2!, 111 4!, 117 8!, 14!, 16! 31 2! 45

More information

LETTER OF TRANSMITTAL

LETTER OF TRANSMITTAL FRANK A. ANZALONE Date: FAA Job No. GENERAL CONTRACTOR 1401 Derek Drive, Suite B Hammond, LA 70403 Phone: (985) 542-2744 Fax: (985) 230-0614 Attention: RE: LETTER OF TRANSMITTAL WE ARE SENDING YOU Attached

More information

4.5 COMPOSITE STEEL AND CONCRETE

4.5 COMPOSITE STEEL AND CONCRETE 4.5 COMPOSITE STEEL AND CONCRETE 4.5.1 RULES OF THUMB 4.5 Composite Steel and Concrete (1/11) Typical starting point Overall concrete depth 130mm (Grade 30) Depth of profiled decking 60mm Size beam with

More information

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1464 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 05 00

More information

Expanding Your Solutions. ViperStud Product Catalog. Interior Non-Load Bearing Studs and Track

Expanding Your Solutions. ViperStud Product Catalog. Interior Non-Load Bearing Studs and Track Expanding Your Solutions ViperStud Product Catalog Interior Non-Load Bearing Studs and Track Effective 5/11/18 #VSB5-5/15 By providing a lighter, stronger, more efficient framing system, ViperStud has

More information

Number: 161. Originally Issued: 06/24/2010 Revised: 08/03/2017 Valid Through: 06/30/2018

Number: 161. Originally Issued: 06/24/2010 Revised: 08/03/2017 Valid Through: 06/30/2018 ASC STEEL DECK STEEL ROOF DECK CSI Section: 05 30 00 Metal Decking 05 31 00 Steel Decking 05 31 23 Steel Roof Decking 1.0 RECOGNITION The ASC Profiles Steel Roof Decks recognized in this report have been

More information

Bridge Overhang Brackets

Bridge Overhang Brackets Bridge C49, C49D, C49S and C49JR Bridge Dayton Superior offers the bridge contractor four different Horizontal Length versions of the C49 Bridge Bracket, which allows for maximum adjustability to meet

More information

WESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension

WESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension E N G I N E E R E D W O O D WESTERN SPECIFIER Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension P R O D U C T S JOIST DIMENSIONS 9½ LVL FLANGE PWI JOIST SERIES JOIST DIMENSIONS

More information

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems LVL User s Guide Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems U N I T E D S T A T E S V E R S I O N Quality Products Committed Service O U R H I S TO

More information

American made. American strong. The mark of a true craftsman. A strong history. Mission. . Republic Steel acquires facility from Elyria Iron and Steel

American made. American strong. The mark of a true craftsman. A strong history. Mission. . Republic Steel acquires facility from Elyria Iron and Steel American made. American strong. For more than 85 years, Republic Conduit has manufactured the nation s premier steel electrical conduit. The mark of a true craftsman. Since 1928, Republic Conduit has been

More information

Light gage steel framing

Light gage steel framing Missouri University of Science and Technology Scholars' Mine Center for Cold-Formed Steel Structures Library Wei-Wen Yu Center for Cold-Formed Steel Structures 1-1-2001 Light gage steel framing Dale Industries

More information

FLUSH SEAT DESIGN GUIDE FOR USE WITH ECOSPAN COMPOSITE JOISTS. economy THROUGH ecology. v1.3

FLUSH SEAT DESIGN GUIDE FOR USE WITH ECOSPAN COMPOSITE JOISTS. economy THROUGH ecology. v1.3 FLUSH SEAT DESIGN GUIDE FOR USE WITH ECOSPAN COMPOSITE JOISTS economy THROUGH ecology v1.3 Nucor-Vulcraft / Verco Group Ecospan Composite Floor System 6230 Shiloh Road Suite 140 Alpharetta, GA 30005 P:

More information

western for products manufactured in White City, Oregon

western for products manufactured in White City, Oregon western VERSA-LAM SPECIFIER Guide for products manufactured in White City, Oregon Western VERSA-LAM Guide 11/29/2012 2 VERSA-LAM Products An Introduction to VERSA-LAM Products When you specify VERSA-LAM

More information

Purlins and Girts. A division of Canam Group

Purlins and Girts. A division of Canam Group Purlins and Girts A division of Canam Group TABLE OF CONTENTS OUR SOLUTIONS AND SERVICES............................................................ 5 Cautionary statement..................................................................

More information

TRUS JOIST BEAMS, HEADERS, AND COLUMNS

TRUS JOIST BEAMS, HEADERS, AND COLUMNS FLOOR SOLUTIONS ROOF SOLUTIONS TRUS JOIST BEAMS, HEADERS, AND COLUMNS Featuring TimberStrand LSL, Microllam LVL, and Parallam PSL Uniform and Predictable Minimal Bowing, Twisting, and Shrinking Strong

More information

Allowable Holes in VERSA-LAM Beams

Allowable Holes in VERSA-LAM Beams VERSA-LAM Products 23 An Introduction to VERSA-LAM Products When you specify VERSA-LAM laminated veneer headers/beams, you are building quality into your design. They are excel lent as floor and roof framing

More information

Originally Issued: 09/09/2014 Revised: 09/13/2017 Valid Through: 09/30/2018

Originally Issued: 09/09/2014 Revised: 09/13/2017 Valid Through: 09/30/2018 ASC PROFILES LLC AEP SPAN AND ASC BUILDING PRODUCTS: SINGLE SKIN STEEL ROOF AND WALL PANELS WITH CONCEALED FASTENERS CSI : 07 61 00 Sheet Metal Roofing 07 64 00 Sheet Metal Wall Cladding 1.0 RECOGNITION

More information

STRUCTURAL EDGE ENGINEERING, PLLC

STRUCTURAL EDGE ENGINEERING, PLLC STRUCTURAL EDGE ENGINEERING, PLLC STRUCTURAL CALCULATIONS HINES BLD 3 BOISE, ID SE PROJECT NO: SE16-181 PREPARED FOR: CODE: DATE: NEUDESIGN ARCHITECTURE & LAWSON DESIGN INC 2012 IBC APRIL 23, 2017 683

More information

Pressure control solutions for your industry. Aerospace & Defense

Pressure control solutions for your industry. Aerospace & Defense Pressure control solutions for your industry. Aerospace & Defense Years of experience innovative solutions TESCOM is an experienced provider of high quality regulators, valves, manifolds, custom assemblies

More information

STANDARD SPECIFICATIONS

STANDARD SPECIFICATIONS American National Standard SJI-K 1.1 STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS, K-SERIES SECTION 1. SCOPE Adopted by the Steel Joist Institute November 4, 1985 Revised to November 10, 2003 - Effective

More information

PVC SCHEDULE 40 FITTINGS

PVC SCHEDULE 40 FITTINGS PVC SCHEDULE 40 FITTINGS Performance Engineered & Tested 40-2-0604 SPEARS Schedule 40 PVC fitting designs combine years of proven experience with computer generated stress analysis to yield the optimum

More information

LIGHTWEIGHT STEEL FRAMING METRIC SECTION PROPERTIES

LIGHTWEIGHT STEEL FRAMING METRIC SECTION PROPERTIES C A N A D I A N S H E E T S T E E L B U I L D I N G I N S T I T U T E LIGHTWEIGHT STEEL FRAMING METRIC SECTION PROPERTIES wall stud floor joist track section & bridging channel properties 1 CSSBI 58A-2011

More information

The FRACOF Composite Slab Test

The FRACOF Composite Slab Test The FRACOF Composite Slab Test Experiment, Predictions & Results Anthony Abu & Ian Burgess Fire Resistance Assessment of partially protected COmposite Floors - FRACOF Introduction To increase the use of

More information

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3578 Reissued 0/206 This report is subject to renewal 0/208. DIVISION: 05 00 00 METALS SECTION:

More information

Post-Tensioned Concrete U-Girder Design. Midas Elite Speaker Series. Doug Midkiff, PE AECOM

Post-Tensioned Concrete U-Girder Design. Midas Elite Speaker Series. Doug Midkiff, PE AECOM Post-Tensioned Concrete U-Girder Midas Elite Speaker Series Doug Midkiff, PE AECOM POST-TENSIONED CONCRETE U-GIRDER BRIDGE DESIGN (I-49 LAFAYETTE CONNECTOR) Doug Midkiff Structural Engineer III AECOM E

More information

HSS SECTION PROPERTIES / SQUARES 1 OF 5

HSS SECTION PROPERTIES / SQUARES 1 OF 5 HSS SECTION PROPERTIES / SQUARES 1 OF 5 This publication presents tables of dimensions and section properties for square Hollow Structural Sections (HSS) produced by Bull Moose Tube Company. The dimensions,

More information

STRONGER THAN STEEL. interior and exterior framing

STRONGER THAN STEEL. interior and exterior framing ROUGH OPENINGS PRODUCT CATALOG STRONGER SM THAN STEEL. interior and exterior framing rough openings ROUGH OPENINGS M A D E E A S Y. Rough openings have always been a challenge on the jobsite. At ClarkDietrich,

More information

Design Guide Standard Joists INTERACTIVE PDF

Design Guide Standard Joists INTERACTIVE PDF INTERACTIVE PDF Design Guide Standard s Fully updated to SJI 44 th Edition Standard Specifications Load and weight tables for K, LH, DLH-Series and Girders Economical Design Guide load tables for lowest

More information

STRONGER. COLD-FORMED STRUCTURAL FRAMING PRODUCTS technical design guide

STRONGER. COLD-FORMED STRUCTURAL FRAMING PRODUCTS technical design guide COLD-FORMED STRUCTURAL FRAMING PRODUCTS technical design guide STRONGER T H A N S T E E L. SM M E M B E R P R O P E R T I E S & S PA N S C U R TA I N WA L L S L O A D -B E A R I N G WA L L S J O I S T

More information

COMPOSITE FLOOR SYSTEM

COMPOSITE FLOOR SYSTEM COMPOSITE FLOOR SYSTEM US Technical and Structural Information A VERSATILE, HIGH-STRENGTH, LONG-SPAN FLOORING SOLUTION COMPOSITE FLOORING SYSTEM Proven, reliable, and cost-effective THINFLOR COMPOSITE

More information

Overview. HDS replaces built-up curtain wall headers. HDS replaces load-bearing box beam headers

Overview. HDS replaces built-up curtain wall headers. HDS replaces load-bearing box beam headers Overview The Heavy-Duty Stud (HDS ) Framing System is a high-performance, costeffective, multipurpose, heavy-duty framing stud for headers, jambs, posts and built-up tube truss chords and webs. The superior

More information

BOISE GLULAM 24F-V4 IJC

BOISE GLULAM 24F-V4 IJC Engineered Wood Products 24F-V4 IJC I-Joist Compatible Glulam Guide 3½" x 7½" 3½" x 9½" 3½" x 11⅞" 3½" x 14" 3½" x 16" Sizes Available 5½" x 7½" 5½" x 9½" 5½" x 11⅞" 5½" x 14" 5½" x 16" IJG 01/2010 2 I-Joist

More information

APPENDIX D. D.1 Macalloy Bars. Approximate safe working loads (kn) Appendix D - Proprietary Components (1/9) Stainless steel architectural ties

APPENDIX D. D.1 Macalloy Bars. Approximate safe working loads (kn) Appendix D - Proprietary Components (1/9) Stainless steel architectural ties Appendix D - Proprietary Components (1/9) APPENDIX D D.1 Macalloy Bars Bar dia. mm Stressing ties Stainless steel stressing ties Stainless steel architectural ties High strength Tie rods grades precision

More information

Multideck 60-V2. Contents

Multideck 60-V2. Contents The original and still the most popular deck in the market is a 60mm high, structurally efficient trapezoidal profile providing an excellent composite union between steel and concrete to maximise the load

More information

Premium Structural Engineered Wood Products. Technical Data for. LVL Flange and MSR Flange I-Joists

Premium Structural Engineered Wood Products. Technical Data for. LVL Flange and MSR Flange I-Joists Premium Structural Engineered Wood Products Premium Structural Engineered Wood Products I- USER S guide Technical Data for LVL Flange and MSR Flange I-s THE structural Wood Supplier Wood A renewable building

More information

MBG GRATINGS. MBG Metal Bar Grating HEAVY DUTY MANUAL METAL BAR GRATING AMERICAN NATIONAL STANDARD ANSI/NAAMM STANDARD GRATINGS FIFTH EDITION

MBG GRATINGS. MBG Metal Bar Grating HEAVY DUTY MANUAL METAL BAR GRATING AMERICAN NATIONAL STANDARD ANSI/NAAMM STANDARD GRATINGS FIFTH EDITION METAL BAR GRATING AMERICAN NATIONAL STANDARD ANSI/NAAMM STANDARD MBG 532-09 GRATINGS 5 ANSI/NAAMM HMMA MBG 532-09 October 27, 2009 HEAVY DUTY METAL BAR GRATING MANUAL FIFTH EDITION Maximum Bearing Bar

More information

polylam vertical baffle system Product data sheet durlum.us Your contact for North America

polylam vertical baffle system Product data sheet durlum.us Your contact for North America polylam Your contact for North America Product data sheet 1 1 End cap / end cover with F-lip Connection detail U-Carrier coming soon! POLYLAM puts the architecture in the limelight. This modern vertical

More information

ROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES!

ROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES! ROOF HATCHES SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES! Over 45 years of proven performance in Standard & Custom Designed Hatches ROOF HATCHES Better by design LEXCOR COMPANY PROFILE Lexcor was incorporated

More information

Roof Hatches Smoke Vents /BAB BuyLine 0898

Roof Hatches Smoke Vents /BAB BuyLine 0898 Roof Hatches Smoke Vents 07 72 00/BAB BuyLine 0898 Roof Hatches: Steel & Aluminum Ladder Access Ship Stair Access Designed for fixed ladder roof access 30 x 30 36 x 30 36 x 36 Designed for ship stair roof

More information

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N DESIGN GUIDE PURLINS AND GIRTS ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS S&T029N JUL 2015 CONTENTS INTRODUCTION 2 Acknowledgements 2 Disclaimer 2 Product Technical Statement 3 Producer Statement

More information

Submittal Data. Fiberglass Bondstrand 3000A Pipe

Submittal Data. Fiberglass Bondstrand 3000A Pipe Submittal Data Fiberglass Bondstrand 3000A Pipe Uses and Applications Cooling water General service piping Jet fuel piping Mild chemicals Municipal waste Potable water Power plant, steel mill and industrial

More information

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

SECTION METAL LOCKERS

SECTION METAL LOCKERS SECTION 10 5113 METAL LOCKERS This section includes editing notes to assist the user in editing the section to suit project requirements. These notes are included as hidden text, and can be revealed or

More information

Design principles and Assumptions

Design principles and Assumptions Design principles and Assumptions The design and use of concrete slabs that utilise ARMOURDECK 300 in composite construction may be carried out using either: the relevant Australian and international Standards

More information

BOSS STEEL Metal Reference Book Version 9

BOSS STEEL Metal Reference Book Version 9 Intro BOSS STEEL Metal Reference Book Version 9 This ninth edition of the Boss Steel Metal Reference Book has been designed to inform and assist you in making the right decision when it comes to acquiring

More information

ROUGH OPENINGS PRODUCT CATALOG STRONGER THAN STEEL. INTERIOR AND EXTERIOR FRAMING

ROUGH OPENINGS PRODUCT CATALOG STRONGER THAN STEEL. INTERIOR AND EXTERIOR FRAMING PRODUCT CATALOG STRONGER SM THAN STEEL. INTERIOR AND EXTERIOR FRAMING MADE EASY. Rough openings have always been a challenge on the jobsite. At ClarkDietrich, we make them easy. Our collection of rough

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

STANDARD FOR ROLLING SHEET DOORS

STANDARD FOR ROLLING SHEET DOORS DASMA 207-2008 DASMA STANDARD STANDARD FOR ROLLING SHEET DOORS Door & Access Systems Manufacturers Association, International Sponsor: 1300 Sumner Ave Cleveland, Ohio 44115-2851 DASMA 207-2008 DASMA STANDARD

More information

Anthony Glulam Advantages

Anthony Glulam Advantages GLULAM Table of Contents Glulam Advantages...1 About Us...2 Anthony Power Products Family...3 Design Properties...4-5 V4 1.7E IJC Framing Load Tables...-8 V4 1.7E Stock Depth Industrial Load Tables...-17

More information

EVERSERVE 610S/620S/625S SPRINGLESS ROLLING SERVICE DOORS LOW MAINTENANCE. EASE OF SERVICEABILITY. INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS

EVERSERVE 610S/620S/625S SPRINGLESS ROLLING SERVICE DOORS LOW MAINTENANCE. EASE OF SERVICEABILITY. INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS 610S/620S/625S EVERSERVE SPRINGLESS ROLLING SERVICE DOORS LOW MAINTENANCE. EASE OF SERVICEABILITY. INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS EVERSERVE MODELS 610S/620S/625S SPRINGLESS SERVICE

More information

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-4108 Issued 12/2017 This report is subject to renewal 12/2018. DIVISION: 08 00 00

More information

General Information SECTION DIRECTORY

General Information SECTION DIRECTORY SECTION DIRECTORY General Information Product Summary... V-AW-2 Product Selection Guide... V-AW-3 Size and Performance Data... V-AW-3 Features and Options... V-AW-3 Sound Transmission Class and Outdoor-Indoor

More information

Terms and Conditions

Terms and Conditions Terms and Conditions GUARANTEE: All Brighton-Best International, Inc. products are manufactured to rigid quality control standards which meet or exceed industry standards. Records and tests pertaining

More information

Appendix C - Roll Over Bars Appendix D - Roll Cages

Appendix C - Roll Over Bars Appendix D - Roll Cages NATIONAL SOLOSPORT REGULATIONS AUTOSLALOM Appendix C - Roll Over Bars Appendix D - Roll Cages Effective January 1, 2018 ASN Canada FIA 481 North Service Road West, Suite A21, Oakville, Ontario, L6M 2V6

More information

Automatic Roof Door Vents

Automatic Roof Door Vents DATA SHEET Automatic Roof Door Vents Features n UL Listed for use as an automatic smoke vent n FM Approved as an automatic door vent for use in high expansion foam systems n Available in multiple sizes

More information

NRA 800 Series. Overview. Medium Density Closed Rack Solutions

NRA 800 Series. Overview. Medium Density Closed Rack Solutions NRA Series Overview NRA Series, Rigid Racks for Servers, Networking, AV, Telecom & Lab application. Racks manufactured out of aluminum profile, formed steel frames & members, individually powder coated

More information

INDUSTRIAL SPACE FOR LEASE 4032 PATRIOT DRIVE, DURHAM, NC 27703

INDUSTRIAL SPACE FOR LEASE 4032 PATRIOT DRIVE, DURHAM, NC 27703 32 PATRIOT RIVE, URHAM, NC 273 PARK SITE PL AN PATRIOT RIVE 32 PATRIOT RIVE BUILING 2 X 680 = 63,3 SF BUILING 2 BUILING 3 250 X 750 = 87,500 SF LOT FREEOM COURT LOT 4 Road Proposed BUILING 4 2 X 665 =

More information

1 TAMCO ALUMINUM CONTROL DAMPER Installation Guidelines For Series 1000, 1400, 1500, 9000, 9000 BF FOR TAMCO JACK SHAFTS REFER TO INSTRUCTIONS PROVIDED IN PARTS BOX. FOR TAMCO JUMPERS REFER TO INSTRUCTIONS

More information

ProStar Rolling SheetDoor Systems

ProStar Rolling SheetDoor Systems ProStar Rolling Sheet Door Systems ProStar Rolling SheetDoor Systems Product Line COMMERCIAL WIND LOAD COMMERCIAL DOOR SELF-STORAGE SERIES 790CW 780CD 770SS INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS

More information

B-LINE SERIES SGPC-16. Safety gratings. Safety gratings. Safety for every walk of life

B-LINE SERIES SGPC-16. Safety gratings. Safety gratings. Safety for every walk of life Safety gratings SGPC-16 B-LINE SERIES Safety gratings Safety for every walk of life Product Applications Grip Strut Eaton s B-Line series safety grating offering is ideal for a wide variety of applications.

More information

Multideck 80-V2 Features and Applications

Multideck 80-V2 Features and Applications Features and Applications is designed to incorporate all the advantages of the Multideck 60-V2 but in a deeper profile to provide longer spans up to 5.4m unpropped. Concrete Volume Savings Due to its unique

More information

Clipper Defined. Shelving. Clipper Hi-Performance Shelving Systems. Growth with. Penco Hi-Performance Shelves. Growth with

Clipper Defined. Shelving. Clipper Hi-Performance Shelving Systems. Growth with. Penco Hi-Performance Shelves. Growth with Defined Clipper Hi-Performance Systems At the heart of the Clipper System is the ingenious Penco Clipper Clip. It is easily installed, holds the shelf firmly in place, can be repositioned at any time,

More information

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS For nearly 80 years Behlen Mfg. Co. has focused on meeting customer needs. This is done with

More information

FREE STANDING WORK STATION JIB CRANE

FREE STANDING WORK STATION JIB CRANE SECTION 14661 FREE STANDING WORK STATION JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and

More information

INDUSTRIAL SPACE FOR LEASE 4050 PATRIOT DR., DURHAM, NC 27703

INDUSTRIAL SPACE FOR LEASE 4050 PATRIOT DR., DURHAM, NC 27703 50 PATRIOT R., URHAM, NC 27703 PARK SITE PLAN PATRIOT RIVE BUILING 2 Road Proposed BUILING 2 X 680 = 63,200 SF BUILING 2 2 X 665 = 59,600 SF STREET B STREET A STREET A BUILING 4 20 X 750 = 57,500 SF LOT

More information

EV Traction Dry Cell Battery Technology

EV Traction Dry Cell Battery Technology EV Traction Dry Cell Battery Technology High performance comes standard Superior performance. Engineered to last. RESPONSIBLE Solution Non-gassing and non-spillable Maintenance-free Approved for environmentally

More information

EV Traction Dry Cell Battery Technology

EV Traction Dry Cell Battery Technology EV Traction Dry Cell Battery Technology High performance comes standard Superior performance. Engineered to last. RESPONSIBLE Solution Non-gassing and non-spillable Maintenance-free Approved for environmentally

More information

MINI. Technical Data for. PWI Joists, PWLVL Headers, Beams, and Dimension

MINI. Technical Data for. PWI Joists, PWLVL Headers, Beams, and Dimension E N G I N E E R E D W O O D MINI Technical Data for PWI s, PWLVL Headers, Beams, and Dimension P R O D U C T S S A F E T Y, H A N D L I N G & P E R F O R M A N C E 2 SAFETY & CONSTRUCTION PRECAUTIONS INSTALLATION

More information