Tranquilizer Surge Suppressors for Air-Driven Diaphragm Pumps

Size: px
Start display at page:

Download "Tranquilizer Surge Suppressors for Air-Driven Diaphragm Pumps"

Transcription

1 SERVI & OPERATING MANUAL Tranquilizer Surge Suppressors for Air-Driven Diaphragm Pumps Metallic Construction Table of Contents Product and Operating Principle... Page 1 Materials and Operating Temperatures... Page 2,3 Product Nomenclature Description... Page 2,3 Dimensions... Page 4,5,6,7 Installation Guide...Page 8 Tranquilizer Options...Page 9 Service & Operating Manual... Page 10 Safety Information... Page 10 Repair Parts List... Page 11 Parts Drawing... Page 12 WARREN RUPP, INC., A Unit of IDEX Corporation P.O. Box 1568, Mansfield, Ohio (419) Fax (419) /00 Model TA2

2 Tranquilizer WITHOUT SUPPRESSOR WITH SUPPRESSOR Nearly surge-free flow. Steadier pressures. Less shock to pipes. DISCHARGE PRESSURE PUMP CYCLING RATE Air-operated diaphragm pumps offer a wide range of benefits not available in any other type of pump. However, in some applications, pulsations in the discharge flow may be undesirable. Pulsation can be virtually eliminated by installing a Warren Rupp Tranquilizer. At initial and subsequent start-ups... air cushion is quickly established by liquid pressure pushing diaphragm upward, permitting entrance of air into air chamber, until the balancing air cushion causes the diaphragm to center at its mid-stroke normal operating position. During normal continuous operation thereafter... the diaphragm always flexes at its mid-range position to absorb discharge pulsations against the adjoining air cushion already established. In event of change in pumped liquid pressure... the air cushion pressure is automatically increased or decreased as required to compensate for the change... always maintaining constant volume of air cushion, and the diaphragm always operating at its mid-position. When liquid flow stops and liquid pressure is released... the air in air chamber is also exhausted to atmosphere. Tranquilizer Automatically maintains a constant volume of air cushion for most effective surge suppression, regardless of pump pressure. Automatically self-charging and self-venting to maintain most efficient air cushion pressure... no more precharge pressure calculations or guesswork, no manual pressurizing, no periodic pressure checking. Air cushion separated from product by flexible diaphragm... prevents product aeration. External visual indication provides constant evidence of performance. Simple to install. Attention-free. Model TA1 1-inch Tranquilizer for use with 1-inch pumps Furnished with 13 3 /8" air inlet hose whipline. Connection is external pipe thread. Maximum Operating Pressure. Model TD 1½ / TD 40 1½-inch Tranquilizer for use with 1½-inch pumps Furnished with 13 3 /8" air inlet hose whipline. Connection is external pipe thread. Maximum Operating Pressure. Model TA2 2-inch Tranquilizer for use with 1½, 2-inch pumps Furnished with 13 3 /8" air inlet hose whipline. Connection is external pipe thread. Maximum Operating Pressure. Model TA3/TA80 3-inch Tranquilizer for use with 3-inch pumps Furnished with 13 3 /8" air inlet hose whipline. Connection is external pipe thread. Maximum Operating Pressure /00 Models TA1, TA25, TD1½, TD40, TA2, TA50, TA3 & TA80 Page 1

3 Materials of Construction: Type Code Diaphragm Design Level Wetted Parts (Internal Threads) Flange Style Type Code Diaphragm Style Code Design Level Wetted Parts (Internal Tapered Threads) Flange Style Shipping Weight lbs./kg Tranquilizer Model TA1 B-1-A B 1 A 1" H-1-A H 1 A 1" Tranquilizer Model TA25 BB-1-A B B 1 A 1" BSPT 14 / 6.35 HB-1-A H B 1 A 1" BSPT 14 / 6.35 NG-1-A NG 1 A 1" N-1-A N 1 A 1" S-1-A S 1 A 1" V-1-A V 1 A 1" B-1-SS B 1 SS 1" F-1-SS F 1 SS 1" H-1-SS H 1 SS 1" NG-1-SS NG 1 SS 1" N-1-SS N 1 SS 1" S-1-SS S 1 SS 1" V-1-SS V 1 SS 1" NGB-1-A NG B 1 A 1" BSPT NB-1-A N B 1 A 1" BSPT SB-1-A S B 1 A 1" BSPT VB-1-A V B 1 A 1" BSPT BB-1-SS B B 1 SS 1" BSPT FB-1-SS F B 1 SS 1" BSPT HB-1-SS H B 1 SS 1" BSPT NGB-1-SS NG B 1 SS 1" BSPT NB-1-SS N B 1 SS 1" BSPT SB-1-SS S B 1 SS 1" BSPT VB-1-SS V B 1 SS 1" BSPT 14 / / / / 6.35 Tranquilizer Model TD1½ Tranquilizer Model TD40 B-1-A B 1 A 1½" NG-1-A NG 1 A 1½" N-1-A N 1 A 1½" V-1-A V 1 A 1½" B-1-A B 1 A 1½" F-1-A F 1 A 1½" NG-1-SS NG 1 SS 1½" N-1-SS N 1 SS 1½" BB-1-A B B 1 A 1½" BSPT NGB-1-A NG B 1 A 1½" BSPT NB-1-A N B 1 A 1½" BSPT VB-1-A V B 1 A 1½" BSPT BB-1-SS B B 1 SS 1½" BSPT FB-1-SS F B 1 SS 1½" BSPT NGB-1-SS NG B 1 SS 1½" BSPT NB-1-SS N B 1 SS 1½" BSPT V-1-SS V 1 SS 1½" VB-1-SS V B 1 SS 1½" BSPT Tranquilizer Model TA2 Tranquilizer Model TA50 B-1-A B 1 A 2" I-1-A I 1 A 2" BB-1-A B B 1 A 2" BSPT IB-1-A I B 1 A 2" BSPT NG-1-A NG 1 A 2" N-1-A N 1 A 2" S-1-A S 1 A 2" V-1-A V 1 A 2" B-1-CI B 1 CI 2" NGB-1-A NG B 1 A 2" BSPT NB-1-A N B 1 A 2" BSPT SB-1-A S B 1 A 2" BSPT VB-1-A V B 1 A 2" BSPT BB-1-CI B B 1 CI 2" BSPT I-1-CI I 1 CI 2" NG-1-CI NG 1 CI 2" N-1-CI N 1 SS 2" S-1-CI S 1 CI 2" V-1-CI V 1 CI 2" B-1-SS B 1 SS 2" F-1-SS F 1 SS 2" IB-1-CI I B 1 CI 2" BSPT NGB-1-CI NG B 1 CI 2" BSPT NB-1-CI N B 1 CI 2" BSPT SB-1-CI S B 1 CI 2" BSPT VB-1-CI V B 1 CI 2" BSPT BB-1-SS B B 1 SS 2" BSPT FB-1-SS F B 1 SS 2" BSPT /00 Page 2

4 Materials of Construction continued: Tranquilizer Model TA2, continued Tranquilizer Model TA50, continued Type Code Diaphragm Design Level Wetted Parts (Internal Threads) Flange Style Type Code Diaphragm Style Code Design Level Wetted Parts (Internal Tapered Threads) Flange Style Shipping Weight lbs./kg NG-1-SS NG 1 SS 2" N-1-SS N 1 SS 2" V-1-SS V 1 SS 2" I-1-HC I 1 HC 2" NG-1-HC NG 1 HC 2" N-1-HC N 1 HC 2" NGB-1-SS NG B 1 SS 2" BSPT NB-1-SS N B 1 SS 2" BSPT VB-1-SS V B 1 SS 2" BSPT IB-1-HC I B 1 HC 2" BSPT NGB-1-HC NG B 1 SS 1½" BSPT NB-1-HC N B 1 HC 1½" BSPT V-1-HC V 1 HC 2" Tranquilizer Model TA3 VB-1-HC V B 1 HC 1½" BSPT Tranquilizer Model TA80 B-1-A B 1 A 3" I-1-A I 1 A 3" BB-1-A B B 1 A 3" BSPT PN10 80 mm DIN 89 / 40.4 IB-1-A I B 1 A 3" BSPT 89 / 40.4 NG-1-A N-1-A NG 1 A 3" N 1 A 3" NGB-1-A NB-1-A NG B 1 A 3" BSPT N B 1 A 3" BSPT 89 / / 40.4 V-1-A V 1 A 3" VB-1-A V B 1 A 3" BSPT 89 / 40.4 B-1-CI B 1 CI 3" BB-1-CI B B 1 CI 3" BSPT 109 / 49.4 I-1-CI I 1 CI 3" IB-1-CI I B 1 CI 3" BSPT 109 / 49.4 NG-1-CI NG 1 CI 3" NGB-1-CI NG B 1 CI 3" BSPT 109 / 49.4 N-1-CI N 1 CI 3" NB-1-CI N B 1 CI 3" BSPT 109 / 49.4 V-1-CI V 1 CI 3" B-1-SS B 1 SS 3" NG-1-SS NG 1 SS 3" N-1-SS N 1 SS 3" VB-1-CI V B 1 CI 3" BSPT BB-1-SS B B 1 SS 3" BSPT NGB-1-SS NG B 1 SS 3" BSPT NB-1-SS N B 1 SS 3" BSPT 109 / / / / 47.6 V-1-SS V 1 SS 3" VB-1-SS V B 1 SS 3" BSPT 105 / 47.6 Meaning of A = Aluminum N = Neoprene HC = Warren Rupp Alloy "C" B = Buna-N NG = Neoprene Backup/ (Hastelloy "C" equivalent) Abbreviations: CI = Cast Iron PTFE Overlay Kit available to convert F = FDA White Nitrile S = Santoprene to top porting H = Hytrel V = Viton I = EPDM SS = Warren Rupp Alloy Type 316SS * Most other types available in dual ported design. See price book or consult factory for details. Viton & Hytrel are registered tradenames of E.I. du Pont. Santoprene is a registered tradename of Monsanto Corp. Tranquilizer is a registered tradename of Warren Rupp, Inc. Operating Temperatures MATERIALS Maximum* Minimum* Optimum** BUNA-N General purpose, oil-resistant. Shows good solvent, oil, water and hydraulic fluid resistance. Should not be used with highly polar solvents like acetone and MEK, ozone, chlorinated hydrocarbons and nitro hydrocarbons. NEOPRENE All purpose. Resistant to vegetable oils. Generally not affected by moderate chemicals, fats, greases and many oils and solvents. Generally attacked by strong oxidizing acids, ketones, esters, nitro hydrocarbons and chlorinated aromatic hydrocarbons. HYTREL Good on acids, bases, amines, and glycols at room temperature. VIRGIN PTFE Chemically inert, virtually impervious. Very few chemicals are know to chemically react with Teflon, molten alkali metals, turbulent liquid or gases, fluorine and a few fluoro-chemicals such as chlorine trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures. VITON Shows good resistance to a wide range of oils and solvents; especially all alipphatic, aromatic and halogenated hydrocarbons, acids, animal and vegetables oils. Hot water or hot aqueous solutions (over 70 F) will attack Viton. EPDM Shows very good water and chemical resistance. Has poor resistance to oil and solvents, but is fair in ketones and alcohols. SANTOPRENE Injection molded thermoplastic elastomer with no fabric layer. Long mechanical flex life. Excellent abrasion resistance. WR-S Warren Rupp Alloy Type 316 Stainless Steel equal to or exceeding ASTM specification A743-CF-8M for corrosion resistant iron chromium, iron chromium nickel, and nickel based alloy castings for general applications. Coomonly referred to as 316 Stainless Steel in the pump industry. WR-C Warren Rupp Alloy "C" equal to ASTM A494 CW-12M-1 specification for nickel and nickel alloy castings commonly referred to as Hastelloy "C" alloy in the pump industry. Hastelloy "C" is a registered trademark of the Cabot Corporation. For specific applications, always consult "Chemical Resistance Chart" Technical Bulletin. 190 F 88 C 170 F 77 C- 190 F 88 C 212 F+ 100 C+ 212 F+ 100 C+ 212 F+ 100 C+ 212 F+ 100 C F - 23 C -35 F 37 C -10 F -23 C -35 F -37 C +32 F 0 C -10 F -23 C -10 F -23 C 50 F to 140 F 10 C to 60 C 50 F to 130 F 10 C to 54 C 50 F to 140 F 10 C to 60 C 50 F to 212 F 10 C to 100 C 75 F to 212 F 24 C to 100 C 50 F to 212 F 10 C to 100 C 50 F to 212 F 10 C to 100 C *Definite reduction in service life. **Minimal reduction in service life at ends of range /00 Page 3

5 TA1 ¼' Flexible hose (external) fitting. drain port TA25 Flexible hose (external) fitting. 1" BSPT(Tapered) port drain port /00 Page 4

6 TD1½ Flexible hose (external) fitting. All dimensions +/-1/8" (millimeters) TD40 Flexible hose (external) fitting. All dimensions =/-1/8" (millimeters) 1.1/2" BSPT (TAPERED) PORT 1.1/2" BSPT (TAPERED) PORT /00 Page 5

7 TA2 Flexible hose (external) fitting. TA50 Flexible hose (external) fitting. 2" BSPT (Tapered) thread on centerline /00 Page 6

8 TA3 Flexible hose (external) fitting. TA80 Flexible hose (external) fitting. 3" BSPT (Tapered) Flange M16x2 8 holes on a 160mm diameter Bolt Circle /00 Page 7

9 INSTALLATION GUIDE Top Discharge Ball or Flap Valve Unit Available from Warren Rupp Tranqulizer Filter/Regulator Lubricator Air Dryer 1 CAUTION The air exhaust should be piped to an area for safe disposition of the product being pumped, in the event of a diaphragm failure /00 Page 8

10 Tranquilizer Surge Suppressor Options TA1 1" pumps. 13 air inlet hose whip line supplied. Selfcharging. (external 1" 13 5/8" to 15 1/8" height (346mm to 384mm) 9" diameter (229mm) (F) TA25 1" pumps. 13 air inlet hose whip line supplied. Selfcharging. (external 1" BSPT (tapered internal 13 5/8" to 15 1/8" height (346mm to 384mm) 9" diameter (229mm) (F) TD1½ 1" and 1½" pumps. 11 air inlet hose whip line supplied. Selfcharging. (external 1½" (internal 19 7/8" to 21. 3/8" height (505mm to 543mm) 10½" diameter (267mm) (F) TA40 1" and 1½" pumps. 11 air inlet hose whip line supplied. Selfcharging. (external 1½" BSPT (tapered internal 19 7/8" to 21. 3/8" height (505mm to 543mm) 10½" diameter (267mm) (F) TA2 1½ and 2" pumps. 13 air inlet hose whip line supplied. Selfcharging. (external 2" (internal 20 to 23 3/16" height (514mm to 589mm) 12½" diameter (317mm) (F) TA50 1½ and 2" pumps. 13 air inlet hose whip line supplied. Selfcharging. 2" BSPT (tapered internal 20 to 23 3/16" height (514mm to 589mm) 12½" diameter (317mm) (F) TA3 3" and 4" pumps. 13 air inlet hose whip line supplied. Self- Charging. 3" 150# Ansistyle flange or 3" internal thread 20 1/8" to 23 1/8"m height (511mm to 587mm) 16 3/16" diameter (411mm (F) TA80 3" and 4" pumps. 13 air inlet hose whip line supplied. Self- Charging. 3" BSPT (tapered internal or 80mm DIN-style Flange 20 1/8" to 23 1/8"m height (511mm to 587mm) 16 3/16" diameter (411mm (F) AL=Aluminum B= Buna N CI= Cast iron I= EPDM N= Neoprene Nt= Overlay, Neoprene with PTFE S= Santoprene T= Virgin PTFE V= Viton WR-C= Alloy C (Hastelloy equiv.) WR-S= Alloy 316 stainless steel /00 Page 9

11 SERVI AND OPERATING MANUAL Tranquilizers Models TA1/ TA25/ TD1½/ TD40/ TA2/ TA50/ TA3/ TA80 Metallic Construction OPERATING AND SERVI INSTRUCTIONS This Warren Rupp Tranquilizer is a completely automatic diaphragm fitted surge suppressor to reduce the flow and pressure pulsations in a pumping system characteristic of reciprocating type pumps. Principle of Operation: The Tranquilizer uses a flexible diaphragm to separate a liquid chamber from compressed air chambers. A rod connected to the center of one diaphragm activates the air inlet and exhaust valves, which automatically admit or exhaust air in the air chambers. This maintains the diaphragms in mid-range of stroke for maximum surge suppnession. Installation: Locate the Tranquilizer in discharge piping as close as possible to the pump. The unit will operate in any position. Connect the air inlet connection to the air supply line having the same air pressure as that at the air inlet connection to the pump. Do not exceed 125 PSI. Service Instructions: When service is required, it is important to MAKE RTAIN THAT INLET AIR PRESSURE IS DISCONNECTED. The diaphragms are serviced by simply removing the hex nuts or v-band, and removing the center spool casting. When Virgin PTFE diaphragms are used in conjunction with the elastomeric diaphragms they are placed over the wetted sides of each elastomeric diaphragm. Inlet and exhaust air valves are located externally for easy access and service. Warranty: This unit is guaranteed for a period of five years against defective material and workmanship. IMPORTANT Read these safety warnings and instructions in this manual completely, before installation and start-up of the pulsation dampener. It is the responsibility of the purchaser to retain this manual for reference. Failure to comply with the recommendations stated in this manual will damage the pulsation dampener, and void factory warranty. Minimum are based upon CAUTION mechanical stress only and may be significantly altered by pumping certain chemicals. Consult engineering guides for chemical compatibilities and temperature limits. CAUTION Before surge suppressor operation, inspect all gasketed fasteners for looseness caused by gasket creep. Re-torque loose fasteners to prevent leakage. Follow recommended torques stated in this manual. WARNING Before doing any maintenance on the pulsation dampener, be certain all pressure is completely vented from the pump, suction, discharge, piping, and all other openings and connections. Be certain the air supply is locked out or made non-operational, so that it cannot be started while work is being done on the pump. Be certain that approved eye protection and protective clothing are worn all times in the vicinity of the pump. Failure to follow these recommendations may result in serious injury or death. Without Suppressor With Suppressor Tranquilizer, SandPIPER and Warren Rupp are registered tradenames of Warren Rupp, Inc Warren Rupp, Inc. WARREN RUPP, INC., A Unit of IDEX Corporation P.O. Box 1568, Mansfield, Ohio (419) Fax (419) /00 Page 10

12 ITEM TOTAL NO. PART NUMBER DESCRIPTION RQD Plate, Diaphragm Washer, Lock Plate, Activator Capscrew Body Tube Fitting Hose Assembly Nut, Hex Valve Assembly (Exhaust) 1 Consisting of: Body, Valve (Exhaust) O-Ring Poppet Spring, Compression Plug, Pipe (Special) Cap O-Ring Seal, Shaft Bearing Rod, Activator Rod, Diaphragm Valve Assembly (Inlet) 1 Consisting of: Body, Valve (Inlet) O-Ring Poppet Spring Tube Fitting Clamp, V-Band Diaphragm Diaphragm Diaphragm Diaphragm Diaphragm Diaphragm Nut, Hex Chamber 2" Chamber 2" Chamber 2" Chamber 2" Plate Plate Plate Plate Washer, Flat Cap Capscrew Service Kit Retaining Ring Diaphragm 1 Items 8, 22 & 23 available as Cap Assembly ( ) REPAIR PARTS LIST and DRAWING Tranquilizer Model TA2 Metallic Construction Repair Parts shown in bold face (darker) type are more likely to need replacement after extended periods of normal use. They are readily available from most Warren Rupp distributors. The pump owner may prefer to maintain a limited inventory of these parts in his own stock to reduce repair downtime to a minimum. IMPORTANT: When ordering repair parts always furnish pump model number, serial number and type number. MATERIAL CODES The Last 3 Digits of Part Number 000 Assembly sub assembly; and some purchased items 010 Cast Iron Powered Metal 015 Ductile Iron Ferritic Malleable Iron Music Wire 080 Carbon Steel AISI B Alloy Alloy Type 316 Stainless Steel Alloy Type 316 Stainless Steel (Electro Polished) 112 Alloy C Alloy Type 316 Stainless Steel (Hand Polished) Stainless Steel /302/304 Stainless Steel C Stainless Steel (Martensitic) Stainless Steel (Wrought Martensitic) Stainless Steel (Wrought Martensitic) 148 Hardcoat Anodized Aluminum T4 Aluminum T6 Aluminum T6 Aluminum T4 Aluminum (2023-T351) 154 Almag 35 Aluminum 155 or T6 Aluminum 157 Die Cast Aluminum Alloy # Aluminum Alloy SR Anodized Aluminum 162 Brass Yellow Screw Machine Stock Cast Bronze, Bronze SAE Bronze Bearing Type Oil Impregnated 180 Copper Alloy Kynar Coated 330 Plated Steel 331 Chrome Plated Steel 332 Electroless Nickel Plated 335 Galvanized Steel Zinc Plated Yellow Brass Silver Plated Steel Nickel Plated Filled Nylon Injection Molded # Santoprene - Duro 40D 5; Color: Red Themoplastic Elastomer 356 Hytrel 357 Rupplon (Urethane Rubber) Rupplon (Urethane Rubber) Color coded: PURPLE (Some applications, Compression Mold) Urethane Rubber 360 Buna-N Rubber Color coded: RED Buna-N 363 Viton (Fluorel) Color coded: YELLOW 364 E.P.D.M Rubber Color coded: BLUE 365 Neoprene Rubber Color coded: GREEN Butyl Rubber Color coded: BROWN Philthane (Tuftane) 375 Fluorinated Nitrile High density Polypropylene 405 Cellulose Fibre 408 Cork and Neoprene List Continued next page WARREN RUPP, INC., A Unit of IDEX Corporation P.O. Box 1568, Mansfield, Ohio (419) Fax (419) /00 Model TA2 Page 11

13 MATERIAL CODES The Last 3 Digits of Part Number Continued from previous page 425 Compressed Fibre 426 Blue Gard 440 Vegetable Fibre 465 Fibre 500 Delrin Delrin Acrylic Resin Plastic 520 Injection Molded PVDF Natural Color 540 Nylon 541 Nylon 542 Nylon 544 Nylon Injection Molded 550 Polyethylene 551 Polypropylene 552 Unfilled Polypropylene 553 Unfilled Polypropylene 555 Polyvinyl Chloride 570 Rulon II 580 Ryton 590 Valox 591 Nylatron G-S 592 Nylatron NSB 600 Virgin PTFE 601 Virgin PTFE (Bronze and moly filled) 602 Filled Virgin PTFE 603 Blue Gylon 604 Virgin PTFE 606 Virgin PTFE 610 Virgin PTFE Encapsulated Silicon 611 Virgin PTFE Encapsulated Viton Model TA2 Delrin, Viton and Hytrel are registered tradenames of E.I. DuPont. Gylon is a registered tradename of Garlock. Inc. Nylatron is a registered tradename of Polymer Corp. Rulon II is a registered tradename of Dixion Industries Corp. Hastelloy-C is a registered tradename of Cabot Corp. Ryton is a registered tradename of Phillips Chemical Co. Valox is a registered tradename of General Electric Co. Warren Rupp, Rupplon, SandPIPER, PortaPump, Tranquilizer, and SludgeMaster are registered tradenames of Warren Rupp Inc. For PTFE overlay units only U.S. PATENT NO Warren Rupp, Inc. All rights reserved. Warren Rupp, SandPIPER and Tranquilizer are registered tradenames of Warren Rupp, Inc. Printed in U.S.A. Model TA2 Page /00

Model SB1 1 /2-H Type 1

Model SB1 1 /2-H Type 1 SERVICE AND OPERATING MANUAL Model SB1 1 /2-H Type 1 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your specific model may not be shown. Always refer to the parts list

More information

Tranquilizer. Surge Suppression for Air-Driven Diaphragm Pumps. Visit our website!

Tranquilizer. Surge Suppression for Air-Driven Diaphragm Pumps. Visit our website! Quality System ISO9001 Certified Environmental Management Systems ISO14001 Certified Tranquilizer Surge Suppression for Air-Driven Diaphragm Pumps Virtually surge-free flows Steadier pressures Less vibration

More information

WARREN RUPP, INC. A Unit of IDEX Corporation P.O. Box 1568 Mansfield, Ohio USA (419) Fax (419)

WARREN RUPP, INC. A Unit of IDEX Corporation P.O. Box 1568 Mansfield, Ohio USA (419) Fax (419) A WARREN RUPP PUMP BRAND REPAIR PARTS LIST and DRAWING Model MP05D Design Level 1 ITEM NO. PART NUMBER DESCRIPTION TOTAL RQD. 1 095-051-551 Body, Spool Valve 1 2 031-083-000 Sleeve & Spool Set w/pins 1

More information

Model SMA3-A SLUDGEMASTER

Model SMA3-A SLUDGEMASTER SERVICE AND OPERATING MANUAL Model SMA3-A SLUDGEMASTER PLEASE NOTE! The photos shown in this manual are for general instruction only. YOUR SPECIFIC MODEL MAY NOT BE SHOWN. Always refer to the parts list

More information

Model HD20F. DATA SHEET Specifications & Performance. Non-Metallic Flap Valve Design Level 1. Certified Quality

Model HD20F. DATA SHEET Specifications & Performance. Non-Metallic Flap Valve Design Level 1. Certified Quality DATA SHEET Specifications & Performance Certified Quality Model HD20F Non-Metallic Flap Valve Design Level 1 Quality System ISO 9001 Certified Environmental Management System ISO 14001 Certified Warren

More information

Model SLUDGEMASTER SMA3-A

Model SLUDGEMASTER SMA3-A SERVICE AND OPERATING MANUAL Model SLUDGEMASTER SMA3-A OPERATING INSTRUCTIONS This pump has been tested prior to shipment from factory. The oil reservoir has been partially filled at testing with air motor

More information

WARREN RUPP, INC. A Unit of IDEX Corporation P.O. Box 1568 Mansfield, Ohio USA (419) Fax (419)

WARREN RUPP, INC. A Unit of IDEX Corporation P.O. Box 1568 Mansfield, Ohio USA (419) Fax (419) SERVICE AND OPERATING MANUAL Models EB1½ -SM Type 1 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your specific model may not be shown. Always refer to the parts list and

More information

Model PB 1 /2-A Type 3

Model PB 1 /2-A Type 3 SERVICE AND OPERATING MANUAL Model PB 1 /2-A Type 3 PLEASE NOTE! The photos in this manual are for general instruction only. Your specific model may not be shown. Always refer to the parts list and exploded

More information

WARREN RUPP, INC. A Unit of IDEX Corporation P.O. Box 1568 Mansfield, Ohio USA (419) Fax (419)

WARREN RUPP, INC. A Unit of IDEX Corporation P.O. Box 1568 Mansfield, Ohio USA (419) Fax (419) SERVICE AND OPERATING MANUAL Model PB¾ - A Type 3 PLEASE NOTE! The photos in this manual are for general instruction only. Your specific model may not be shown. Always refer to the parts list and exploded

More information

Models PB1 1 /2-A & PB2-A Type 3

Models PB1 1 /2-A & PB2-A Type 3 SERVICE AND OPERATING MANUAL Models PB1 1 /2-A & PB2-A Type 3 PLEASE NOTE! The photos shown in this manual are for general instruction only. YOUR SPECIFIC MODEL MAY NOT BE SHOWN. Always refer to the parts

More information

Model EB1-SM. Type 3 SERVICE AND OPERATING MANUAL

Model EB1-SM. Type 3 SERVICE AND OPERATING MANUAL SERVICE AND OPERATING MANUAL Model EB1-SM Type 3 PRINCIPLE OF OPERATION This ball check valve pump is powered by compressed air and is a 1:1 pressure ratio design. It alternately pressurizes the inner

More information

Model SB1-A Model SB25A

Model SB1-A Model SB25A SERVICE AND OPERATING MANUAL AL II 2GD b T5 CE Model SB1-A Model SB25A Type 4 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your specific model may not be shown. Always

More information

ET Model Pumps Spill Containment Type 3

ET Model Pumps Spill Containment Type 3 SERVICE AND OPERATING MANUAL ET Model Pumps Spill Containment Type 3 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your specific model may not be shown. Always refer to

More information

HDF3-A Type 7 HDF4-A Type 3

HDF3-A Type 7 HDF4-A Type 3 Quality System ISO 9001 Certified Environmental Management System ISO 14001 Certified See pages 16 for ATEX ratings Heavy Duty Flap Valve HDF3-A Type 7 HDF4-A Type 3 Air-Operated Double Pump ENGINEERING,

More information

Models HDF3-A Type 7 HDF4-A Type 3. Table of Contents SERVICE AND OPERATING MANUAL

Models HDF3-A Type 7 HDF4-A Type 3. Table of Contents SERVICE AND OPERATING MANUAL SERVICE AND OPERATING MANUAL II 2GD T5 CE Models HDF3-A Type 7 HDF4-A Type 3 Table of Contents Principle of Operation... 1 Installation and Start-Up... 1 Air Supply... 1 Air Inlet & Priming... 1 ESADS+Plus

More information

Model DA05 Model DA07 Model DA10

Model DA05 Model DA07 Model DA10 SERVICE & OPERATING MANUAL Original Instructions Quality System ISO9001 Certified Environmental Management System ISO14001 Certified Model DA05 Model DA07 Model DA10 Metallic and Non-Metallic Surge Dampeners

More information

Model T15. DATA SHEET Specifications & Performance. Food Processing Metallic Design Level 1. Certified Quality

Model T15. DATA SHEET Specifications & Performance. Food Processing Metallic Design Level 1. Certified Quality DATA SHEET Specifications & Performance Certified Quality Model T15 Food Processing Metallic Design Level 1 Quality System ISO91 Certified Environmental Management System ISO141 Certified Warren Rupp,

More information

Model SA1-A Model SA25A

Model SA1-A Model SA25A SERVICE AND OPERATING MANUAL AL II 2GD b T5 CE Model SA1-A Model SA25A Type 4 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your specific model may not be shown. Always

More information

Model W09 2" Non-Clog Wastewater Air-Operated Double Diaphragm Pump

Model W09 2 Non-Clog Wastewater Air-Operated Double Diaphragm Pump SERVICE AND OPERATING MANUAL Model W09 2" Non-Clog Wastewater Air-Operated Double Diaphragm Pump CE Flap Valve Type 1 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your

More information

SERVICE AND OPERATING MANUAL Model ST1-A Model ST25A. Type 4

SERVICE AND OPERATING MANUAL Model ST1-A Model ST25A. Type 4 II 2GD T5 CE SERVICE AND OPERATING MANUAL Model ST1-A Model ST25A Type 4 Principle of Operation This ball check valve pump is powered by compressed air and is a 1:1 pressure ratio design. It alternately

More information

See pages 2, 7 and 8 for ATEX ratings. AIR VALVE No-lube, no-stall design 30(51) 35(00) U.S. Gallons per minute

See pages 2, 7 and 8 for ATEX ratings. AIR VALVE No-lube, no-stall design 30(51) 35(00) U.S. Gallons per minute Quality System ISO9001 Certified Environmental Management System ISO14001 Certified U1F Metallic Ball Valve Design Level 1 Air-Operated Double Diaphragm Pump See pages 2, 7 and 8 for ATEX ratings. ENGINEERING,

More information

Model ST1½-A Type 4 Model ST40-A Type 4

Model ST1½-A Type 4 Model ST40-A Type 4 I M2 c T5 II 2GD T5 SERVICE AND OPERATING MANUAL CE Model ST1½-A Type 4 Model ST40-A Type 4 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your specific model may not be

More information

II 2G c T5 II 2 D c T100 C

II 2G c T5 II 2 D c T100 C SERVICE AND OPERATING MANUAL II 2G c T5 II 2 D c T100 C Model EH2-M & SH2-M HIGH PRESSURE DUTY Type 4 PRINCIPLE OF OPERATION This pump is a 2:1 pressure ratio single acting pump powered by compressed air.

More information

See pages 5 & 6 for ATEX ratings II 2GD T5. AIR VALVE No-lube, no-stall design 50(85) 60(101.9) 70(118.9) 80(135.9) 90(152.9) 100(169.

See pages 5 & 6 for ATEX ratings II 2GD T5. AIR VALVE No-lube, no-stall design 50(85) 60(101.9) 70(118.9) 80(135.9) 90(152.9) 100(169. Quality System ISO9001 Certified Environmental Management System ISO14001 Certified II 2GD T5 See pages 5 & 6 for ATEX ratings Heavy Duty Flap Valve HDF2 Type 6 Air-Operated Double Diaphragm Pump ENGINEERING,

More information

AIR VALVE No-lube, no-stall design 16 (27) 18 (30) U.S. Gallons per minute Liters per minute CAPACITY

AIR VALVE No-lube, no-stall design 16 (27) 18 (30) U.S. Gallons per minute Liters per minute CAPACITY Quality System ISO9001 Certified Environmental Management System ISO14001 Certified S05 Metallic Design Level 1 Ball Valve Air-Operated Double Diaphragm Pump For See ATEX page ratings 2 see for pages ATEX

More information

Model SET1-A Sanitary Type 3

Model SET1-A Sanitary Type 3 SERVICE AND OPERATING MANUAL Model SET1-A Sanitary Type 3 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your specific model may not be shown. Always refer to the parts

More information

Warren Rupp, Inc. A Unit of IDEX Corporation P.O. Box 1568, Mansfield, Ohio USA Tel: (419) Fax (419)

Warren Rupp, Inc. A Unit of IDEX Corporation P.O. Box 1568, Mansfield, Ohio USA Tel: (419) Fax (419) SERVICE & OPERATING MANUAL Model S1F Non-Metallic Design Level 3 Table of Contents Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature... 2 Performance Curve, Model S1F Non-Metallic

More information

Model S20 Non-Metallic Design Level 2

Model S20 Non-Metallic Design Level 2 SERVICE & OPERATING MANUAL CE Model S20 Non-Metallic Design Level 2 Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature... 2 Performance Curve, Model S20 Non-Metallic Design

More information

Model S1F Metallic Design Level 1 Including T1F FDA Compliant Models Table of Contents

Model S1F Metallic Design Level 1 Including T1F FDA Compliant Models Table of Contents SERVICE & OPERATING MANUAL Model S1F Metallic Design Level 1 Including T1F FDA Compliant Models Table of Contents Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature... 2

More information

Model MSA3, MSA3-C Type 7 Mine/Construction-Duty. Table of Contents SERVICE AND OPERATING MANUAL

Model MSA3, MSA3-C Type 7 Mine/Construction-Duty. Table of Contents SERVICE AND OPERATING MANUAL Table of Contents SERVICE AND OPERATING MANUAL II 2GD T5 CE Model MSA3, MSA3-C Type 7 Mine/Construction-Duty Principle of Operation... 1 Installation and Start-Up... 1 Air Supply... 1 Air Inlet & Priming...

More information

U.S. Patent # 400,210; 5,996,627; 6,241,487

U.S. Patent # 400,210; 5,996,627; 6,241,487 SERVICE & OPERATING MANUAL Model S15 Non-Metallic Design Level 2 Table of Contents Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature... 2 Performance Curve, Model S15 Non-Metallic

More information

Model S1F Non-Metallic Design Level 3

Model S1F Non-Metallic Design Level 3 SERVICE & OPERATING MANUAL Model S1F Non-Metallic Design Level 3 Table of Contents CE U.S. Patent # 400,210 5,996,627 6,241,487 Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature...

More information

II 2GD T5. U.S. Patent #5,996,627 & 6,241,487 Other U.S. Patents Applied for. AIR VALVE No-lube, no-stall design

II 2GD T5. U.S. Patent #5,996,627 & 6,241,487 Other U.S. Patents Applied for. AIR VALVE No-lube, no-stall design Quality System ISO91 Certified Environmental Management System ISO141 Certified CE II 2GD T5 S2 Non-Metallic Design Level 3 Ball Valve Air-Operated Double Diaphragm Pump U.S. Patent #5,996,627 & 6,241,487

More information

II 2GD b T5. AIR VALVE No-lube, no-stall design 16 (27) 18 (30) U.S. Gallons per minute. Liters per minute. Capacity

II 2GD b T5. AIR VALVE No-lube, no-stall design 16 (27) 18 (30) U.S. Gallons per minute. Liters per minute. Capacity Quality System ISO91 Certified Environmental Management System ISO141 Certified S5 S5 Metallic Design Level 1 all Valve U.S. Patent # 5,996,627; 6,241,487 Other U.S. Patents pplied for CE II 2GD b T5 ir-powered

More information

Model G20. DATA SHEET Specifications & Performance. Metallic Design Level 1. Natural Gas-Operated Diaphragm Pumps.

Model G20. DATA SHEET Specifications & Performance. Metallic Design Level 1. Natural Gas-Operated Diaphragm Pumps. DATA SHEET Specifications & Performance Certified Quality Model G20 Metallic Design Level 1 Natural Gas-Operated Diaphragm Pumps Quality System ISO9001 Certified Environmental Management System ISO14001

More information

Model G1F. DATA SHEET Specifications & Performance. Metallic Design Level 1 Natural Gas-Operated Diaphragm Pumps.

Model G1F. DATA SHEET Specifications & Performance. Metallic Design Level 1 Natural Gas-Operated Diaphragm Pumps. DATA SHEET Specifications & Performance Certified Quality Model G1F Metallic Design Level 1 Natural Gas-Operated Diaphragm Pumps Quality System ISO9001 Certified Environmental Management System ISO14001

More information

Model SET2-A Sanitary Type 3

Model SET2-A Sanitary Type 3 SERVICE AND OPERATING MANUAL Model SET2-A Sanitary Type 3 PLEASE NOTE! The photos shown in this manual are for general instruction only. Your specific model may not be shown. Always refer to the parts

More information

Model S05 Non-Metallic Design Level 1

Model S05 Non-Metallic Design Level 1 SERVICE & OPERATING MANUAL Model S05 Non-Metallic Design Level 1 Table of Contents Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature... 2 Performance Curve... 3 Dimensions...

More information

TA1. SERVICE & OPERATING MANUAL Original Instructions. Metallic Construction Design Level 1. Certified Quality 1: SPECS 2: INSTAL & OP 3: EXP VIEW

TA1. SERVICE & OPERATING MANUAL Original Instructions. Metallic Construction Design Level 1. Certified Quality 1: SPECS 2: INSTAL & OP 3: EXP VIEW SERVICE & OPERATING MANUAL Original Instructions Certified Quality TA1 Metallic Construction Design Level 1 1: SPECS 2: INSTAL & OP ISO 9001 Certified ISO 14001 Certified 4: WARRANTY 3: EXP VIEW Warren

More information

ST1 Type 5 ST25 Type 5

ST1 Type 5 ST25 Type 5 Quality System ISO9001 Certified Environmental Management System ISO14001 Certified Containment Duty ST1 Type 5 ST25 Type 5 Air-Operated Double Pump See pages 17 & 18 for ATEX ratings. ENGINEERING, PERFORMANCE

More information

Model B75 Metallic Design Level 1

Model B75 Metallic Design Level 1 SERVICE & OPERATING MANUAL Model B75 Metallic Design Level 1 U.S. Patent # 5,996,627; 6,241,487 Other U.S. Patents Applied for CE I M2 c/b T5 II 2GD b T5 Table of Contents Engineering Data and Temperature

More information

See pages 18 for ATEX ratings

See pages 18 for ATEX ratings SERVICE & OPERATING MANUAL Original Instructions See pages 18 for ATEX ratings Model HDB2 Type 3 Table of Contents Engineering Data and Performance Curve... 1 Explanation of Pump Nomenclature... 2 Dimensions...

More information

See pages 16 & 17 for ATEX ratings

See pages 16 & 17 for ATEX ratings SERVICE AND OPERATING MANUAL See pages 16 & 17 for ATEX ratings Models HDF3-A Type 7 HDF4-A Type 3 Table of Contents Engineering Data and Performance Curve... 1 Explanation of Pump Nomenclature... 2 Dimensions...

More information

SANDPIPER. Model S05 Non-Metallic Design Level 2. Table of Contents SERVICE & OPERATING MANUAL

SANDPIPER. Model S05 Non-Metallic Design Level 2. Table of Contents SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL SANDPIPER A WARREN RUPP PUMP BRAND Model S05 Non-Metallic Design Level 2 Table of Contents U.S. Patent # 400,210; 5,996,627; 6,241,487 CE Engineering Data and Temperature Limitations...

More information

Table of Contents SERVICE & OPERATING MANUAL

Table of Contents SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL Models 4051, 4053 Design Level 2 Table of Contents Engineering Data and Temperature Limitations... 1 Performance Curve... 2 Dimensions... 3 Metric Dimensions... 4 Principle of

More information

**Air Valve w/stroke Indicator Drawing and Parts List **Air Valve w/stroke Indicator Servicing **Solenoid Shifted Air Valve Drawing...

**Air Valve w/stroke Indicator Drawing and Parts List **Air Valve w/stroke Indicator Servicing **Solenoid Shifted Air Valve Drawing... SERVICE & OPERATING MANUAL I M2 c/b T5 II 2GD b T5 Model S15 Metallic Design Level 1 Including T15 FDA A Compliant Models Table of Contents Engineering Data and Temperature Limitations... 1 Explanation

More information

Table of Contents. Type 2. SERVICE AND OPERATING MANUAL Model HDF3-M & HDF4-M

Table of Contents. Type 2. SERVICE AND OPERATING MANUAL Model HDF3-M & HDF4-M SERVICE AND OPERATING MANUAL Model HDF3-M & HDF4-M Type 2 See pages 15 Table of Contents Engineering Data and Performance Curve... 1 Explanation of Pump Nomenclature... 2 Dimensions... 3 Principle of Operation...

More information

See pages 2, 7 and 8 for ATEX ratings. AIR VALVE No-lube, no-stall design

See pages 2, 7 and 8 for ATEX ratings. AIR VALVE No-lube, no-stall design Quality System ISO9001 Certified Environmental Management System ISO14001 Certified S30 Metallic Design Level 1 Ball Valve Air-Operated Double Diaphragm Pump See pages 2, 7 and 8 for ATEX ratings. ENGINEERING,

More information

Model S15. DATA SHEET Specifications & Performance. Non-Metallic Design Level 3. Certified Quality

Model S15. DATA SHEET Specifications & Performance. Non-Metallic Design Level 3. Certified Quality DATA SHEET Specifications & Performance Certified Quality Model S15 n-metallic Design Level 3 Quality System ISO91 Certified Environmental Management System ISO141 Certified Warren Rupp, Inc. A Unit of

More information

Model S30 Non-Metallic Design Level 2 Table of Contents

Model S30 Non-Metallic Design Level 2 Table of Contents SERVICE & OPERATING MANUAL Original Instructions Model S30 Non-Metallic Design Level 2 Table of Contents Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature... 2 Performance

More information

Model S05 Metallic Design Level 1

Model S05 Metallic Design Level 1 SERVICE & OPERATING MANUAL Model S05 Metallic Design Level 1 U.S. Patent # 5,996,627 & 6,241,487 Other U.S. Patents Applied for CE II 2GD b T5 Table of Contents Engineering Data and Temperature Limitations...

More information

Model HDB1½-A Type 7 Model HDB40-A Type 7. Table of Contents SERVICE AND OPERATING MANUAL

Model HDB1½-A Type 7 Model HDB40-A Type 7. Table of Contents SERVICE AND OPERATING MANUAL Table of Contents SERVICE AND OPERATING MANUAL CE I M2 c T5 II 2GD T5 Model HDB1½-A Type 7 Model HDB40-A Type 7 Principle of Operation... 1 Installation and Start-Up... 1 Air Supply... 1 Installation Guide...

More information

**Air Valve Drawing, Parts List, Service Instructions (Aluminum Centers Only) 16

**Air Valve Drawing, Parts List, Service Instructions (Aluminum Centers Only) 16 SERVICE & OPERATING MANUAL SANDPIPER A WARREN RUPP PUMP BRAND Model S15 Metallic Design Level 1 Including T15 FDA Compliant Models Table of Contents Engineering Data and Temperature Limitations... 1 Explanation

More information

SERVICE & OPERATING MANUAL. Original Instructions See pages 18 for ATEX ratings

SERVICE & OPERATING MANUAL. Original Instructions See pages 18 for ATEX ratings SERVICE & OPERATING MANUAL Original Instructions See pages 18 for ATEX ratings Model HDB2 Type 3 Table of Contents Engineering Data and Performance Curve... 1 Explanation of Pump Nomenclature... 2 Dimensions...

More information

Model HD20F. SERVICE & OPERATING MANUAL Original Instructions. Non-Metallic Flap Valve Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTALL & OP

Model HD20F. SERVICE & OPERATING MANUAL Original Instructions. Non-Metallic Flap Valve Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTALL & OP SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model HD20F Non-Metallic Flap Valve Design Level 1 1: PUMP SPECS 2: INSTALL & OP Quality System ISO 9001 Certified Environmental Management

More information

SANDPIPER. Model S07 Non-Metallic. Design Level 1. Table of Contents SERVICE & OPERATING MANUAL. U.S. Patent # 400,210 5,996,627; 6,241,487

SANDPIPER. Model S07 Non-Metallic. Design Level 1. Table of Contents SERVICE & OPERATING MANUAL. U.S. Patent # 400,210 5,996,627; 6,241,487 SERVICE & OPERATING MANUAL SANDPIPER A WARREN RUPP PUMP BRAND Model S07 Non-Metallic Design Level 1 U.S. Patent # 400,210 5,996,627; 6,241,487 CE Table of Contents Engineering Data and Temperature Limitations...

More information

AIR VALVE No-lube, no-stall design. SOLIDS-HANDLING Up to.71 in. (18mm)

AIR VALVE No-lube, no-stall design. SOLIDS-HANDLING Up to.71 in. (18mm) B75 Non-Metallic Design Level 2 Ball Valve Air-Powered Double-Diaphragm Pump Air Exhaust Side View Air Inlet Side View ENGINEERING, PERFORMANCE & CONSTRUCTION DATA INTAKE/DISCHARGE PIPE SIZE 3" ANSI Flange

More information

See pages 17 & 18 for ATEX ratings

See pages 17 & 18 for ATEX ratings SERVICE AND OPERATING MANUAL See pages 17 & 18 for ATEX ratings Models HDB3/HDB4 Type 3 Table of Contents Engineering Data and Performance Curve... 1 Explanation of Pump Nomenclature... 2 Dimensions...3-4

More information

SERVICE AND OPERATING MANUAL Original Instructions ET Model Pumps CONTAINMENT DUTY Type 3

SERVICE AND OPERATING MANUAL Original Instructions ET Model Pumps CONTAINMENT DUTY Type 3 SERVICE AND OPERATING MANUAL Original Instructions ET Model Pumps CONTAINMENT DUTY Type 3 Table of Contents Engineering Data, Temperature Limitations, & Performance Curve... 1 Explanation of Pump Nomenclature...

More information

See pages 2, 13 and 14 for ATEX ratings.

See pages 2, 13 and 14 for ATEX ratings. SERVICE & OPERATING MANUAL Original Instructions Model PB¼ Type 3 Air-Operated Double Diaphragm Pump See pages 2, 13 and 14 for ATEX ratings. Table of Contents Engineering Data and Temperature Limitations...1

More information

SERVICE AND OPERATING MANUAL. See pages 16 for ATEX ratings

SERVICE AND OPERATING MANUAL. See pages 16 for ATEX ratings SERVICE AND OPERATING MANUAL See pages 16 for ATEX ratings Models HDF3-A Type 7 HDF4-A Type 3 Table of Contents Engineering Data and Performance Curve... 1 Explanation of Pump Nomenclature... 2 Recycling...

More information

Model U1F Metallic Design Level 1

Model U1F Metallic Design Level 1 SERVICE & OPERATING MANUAL Original Instructions See pages 2, 24 and 25 II for 2GD ATEX ratings. T5 Model U1F Metallic Design Level 1 Table of Contents Engineering Data and Temperature Limitations... 1

More information

Model U1F Metallic Design Level 1

Model U1F Metallic Design Level 1 SERVICE & OPERATING MANUAL Original Instructions See pages 2, 24 and 25 II for 2GD ATEX ratings. T5 Model U1F Metallic Design Level 1 Table of Contents Engineering Data and Temperature Limitations... 1

More information

4" 150# ANSI FLANGE 8X.75 HOLES EQUALLY HDB3/HDB4. Heavy Duty Ball Valve. Design Level " 150# ANSI FLANGE

4 150# ANSI FLANGE 8X.75 HOLES EQUALLY HDB3/HDB4. Heavy Duty Ball Valve. Design Level  150# ANSI FLANGE AIR INLET 3/4" NPT 18.32 465 Certified Quality 31.19 792 DISCHARGE PORT 4" 150# ANSI FLANGE SERVICE & OPERATING 8X MANUAL.75 HOLES EQUALLY Original Instructions HDB3/HDB4 Heavy Duty Ball Valve 19.25 489

More information

Model S30. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW

Model S30. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model S30 Metallic Design Level 1 1: PUMP SPECS OPTIMIZED PERFORMANCE ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 2:

More information

HDB3/HDB4 SERVICE & OPERATING 8X MANUAL. Heavy Duty Ball Valve. Design Level 4. Original Instructions. Certified Quality 1: PUMP SPECS 2: INSTAL & OP

HDB3/HDB4 SERVICE & OPERATING 8X MANUAL. Heavy Duty Ball Valve. Design Level 4. Original Instructions. Certified Quality 1: PUMP SPECS 2: INSTAL & OP AIR INLET 3/4" NPT 18.32 465 Certified Quality 31.19 792 DISCHARGE PORT 4" 150# ANSI FLANGE SERVICE & OPERATING 8X MANUAL.75 HOLES EQUALLY Original Instructions HDB3/HDB4 Heavy Duty Ball Valve 19.25 489

More information

Model SA1 & SA25. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 5. Certified Quality 1: PUMP SPECS

Model SA1 & SA25. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 5. Certified Quality 1: PUMP SPECS SERVICE & OPERATING MANUAL Original Instructions Certified Quality Quality System ISO 9001 Certified Model SA1 & SA25 Heavy Duty Flap Valve Design Level 5 9.00 229 DISCHARGE P 1" FNPT (HDF1 1" BSPT (HDF2

More information

HDB1½ / HDB40. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 7. Certified Quality

HDB1½ / HDB40. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 7. Certified Quality SERVICE & OPERATING MANUAL Original Instructions Certified Quality HDB1½ / HDB40 Heavy Duty Ball Valve Design Level 7 1: PUMP SPECS 2: INSTAL & OP UCTION PORT 1/2" NPT (1 1/2" BSP TAPERED) Quality System

More information

Model S10 Non-Metallic Design Level 1

Model S10 Non-Metallic Design Level 1 SERVICE & OPERATING MANUAL Model S10 Non-Metallic Design Level 1 Table of Contents Engineering Data and Temperature Limitations...1 Explanation of Pump Nomenclature...2 Performance Curve...3 Dimensions:

More information

Tranquilizer. Surge Suppressors for Air-Driven Diaphragm Pumps. Metallic Construction. Table of Contents

Tranquilizer. Surge Suppressors for Air-Driven Diaphragm Pumps. Metallic Construction. Table of Contents SERICE & OPERTI MUL Original Instructions Quality System ISO900 Certified Environmental Management System ISO400 Certified Tranquilizer Surge Suppressors for ir-driven Diaphragm Pumps Metallic Construction

More information

Model S30 Non-Metallic Design Level 2 Table of Contents

Model S30 Non-Metallic Design Level 2 Table of Contents SERVICE & OPERATING MANUAL Original Instructions Model S30 Non-Metallic Design Level 2 Table of Contents Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature... 2 Performance

More information

Model S30 Non-Metallic Design Level 2 Table of Contents

Model S30 Non-Metallic Design Level 2 Table of Contents SERVICE & OPERATING MANUAL Original Instructions Model S30 Non-Metallic Design Level 2 Table of Contents Engineering Data and Temperature Limitations... 1 Explanation of Pump Nomenclature... 2 Performance

More information

Model M15 Metallic Design Level 1

Model M15 Metallic Design Level 1 SERVICE & OPERATING MANUAL Original Instructions See pages 2, 30 and 31 for ATEX ratings. Model M15 Metallic Design Level 1 Table of Contents Engineering Data and Temperature Limitations... 1 Explanation

More information

Model HDF3M & HDF4M. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 2. Certified Quality 1: PUMP SPECS

Model HDF3M & HDF4M. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 2. Certified Quality 1: PUMP SPECS SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model HDF3M & HDF4M Heavy Duty Flap Valve Design Level 2 1: PUMP SPECS ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 2:

More information

Model HDF1 & HDF25. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 2. Certified Quality

Model HDF1 & HDF25. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 2. Certified Quality SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model HDF1 & HDF25 Heavy Duty Flap Valve Design Level 2 1: PUMP SPECS Quality System ISO9001 Certified Environmental Management System

More information

HDB1½ / HDB40. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 7. Certified Quality

HDB1½ / HDB40. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 7. Certified Quality SERVICE & OPERATING MANUAL Original Instructions Certified Quality HDB1½ / HDB40 Heavy Duty Ball Valve Design Level 7 1: PUMP SPECS 2: INSTAL & OP UCTION PORT 1/2" NPT (1 1/2" BSP TAPERED) 3: EXP VIEW

More information

AIR VALVE No-lube, no-stall design. SOLIDS-HANDLING Up to 1 / 32" (1mm) 6(10.2) U.S. Gallons per minute

AIR VALVE No-lube, no-stall design. SOLIDS-HANDLING Up to 1 / 32 (1mm) 6(10.2) U.S. Gallons per minute Quality System ISO9001 Certified Environmental Management System ISO14001 Certified See pages 2, 13 and 14 for ATEX ratings. Model PB¼ Type 3 Air-Operated Double Diaphragm Pump Engineering, Performance

More information

HDB2 / HDB50. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 3. Certified Quality 1: PUMP SPECS 2: INSTAL & OP

HDB2 / HDB50. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 3. Certified Quality 1: PUMP SPECS 2: INSTAL & OP SERVICE & OPERATING MANUAL Original Instructions Certified Quality HDB2 / HDB50 Heavy Duty Ball Valve Design Level 3 1: PUMP SPECS ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 2: INSTAL

More information

HDB2 / HDB50. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 4. Certified Quality 1: PUMP SPECS 2: INSTAL & OP

HDB2 / HDB50. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 4. Certified Quality 1: PUMP SPECS 2: INSTAL & OP SERVICE & OPERATING MANUAL Original Instructions Certified Quality HDB2 / HDB50 Heavy Duty Ball Valve Design Level 4 1: PUMP SPECS ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 2: INSTAL

More information

Model S20. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality

Model S20. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model S20 Metallic Design Level 1 1: PUMP SPECS Quality System ISO9001 Certified Environmental Management System ISO14001 Certified 5:

More information

Model S1F. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW

Model S1F. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model S1F Metallic Design Level 1 1: PUMP SPECS Quality System ISO 9001 Certified Environmental Management System ISO 14001 Certified

More information

Model HDF3-A Type 7 & HDF4-A Type 3 Heavy Duty Flap Valve

Model HDF3-A Type 7 & HDF4-A Type 3 Heavy Duty Flap Valve SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model HDF3-A Type 7 & HDF4-A Type 3 Heavy Duty Flap Valve 1: PUMP SPECS ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 2:

More information

Table of Contents. Model SSB1 SERVICE AND OPERATING MANUAL. Type 3

Table of Contents. Model SSB1 SERVICE AND OPERATING MANUAL. Type 3 SERVICE AND OPERATING MANUAL CE Model SSB1 II 2GD c T5 Model DSB1-This Model is not ATEX Compliant Type 3 Table of Contents Principle of Operation... 1 Installation and Start-Up... 1 Air Supply... 1 Air

More information

HDB1½ / HDB40. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 8. Certified Quality

HDB1½ / HDB40. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level 8. Certified Quality SERVICE & OPERATING MANUAL Original Instructions Certified Quality HDB1½ / HDB40 Heavy Duty Ball Valve Design Level 8 1: PUMP SPECS UCTION PORT ISO 9001 Certified ISO 14001 Certified 1/2" NPT (1 1/2" BSP

More information

Model HDF2 & HDF50. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 6. Certified Quality 1: PUMP SPECS

Model HDF2 & HDF50. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 6. Certified Quality 1: PUMP SPECS SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model HDF2 & HDF50 Heavy Duty Flap Valve Design Level 6 1: PUMP SPECS ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 2:

More information

Model T1F. SERVICE & OPERATING MANUAL Original Instructions. Food Processing Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP

Model T1F. SERVICE & OPERATING MANUAL Original Instructions. Food Processing Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model T1F Food Processing Metallic Design Level 1 ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 1: PUMP SPECS 2: INSTAL

More information

Model HDF1 & HDF25. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 2. Certified Quality 1: PUMP SPECS

Model HDF1 & HDF25. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 2. Certified Quality 1: PUMP SPECS SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model HDF1 & HDF25 Heavy Duty Flap Valve Design Level 2 1: PUMP SPECS ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 2:

More information

See pages 17 for ATEX ratings

See pages 17 for ATEX ratings See pages 17 for ATEX ratings SERVICE & OPERATING MANUAL Original Instructions Model HDF2 Type 6 Table of Contents Engineering Data and Performance Curve... 1 Explanation of Pump Nomenclature... 2 Recycling...

More information

Model S20. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW

Model S20. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model S20 Metallic Design Level 1 OPTIMIZED PERFORMANCE 1: PUMP SPECS ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 2:

More information

Model T20. SERVICE & OPERATING MANUAL Original Instructions. Food Processing Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP

Model T20. SERVICE & OPERATING MANUAL Original Instructions. Food Processing Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model T20 Food Processing Metallic Design Level 1 ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 3: EXP VIEW 1: PUMP SPECS

More information

HDB3/HDB4. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level Certified Quality 1: PUMP SPECS

HDB3/HDB4. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Ball Valve Design Level Certified Quality 1: PUMP SPECS 26.06 662 SERVICE & OPERATING MANUAL Original Instructions Certified Quality 37.15 944 DISCHARGE PORT 4" 150# ANSI FLANGE 8X.75 HOLES EQUALLY SPACED ON A 7.50 B.C. AIR INLET 3/4" NPT HDB3/HDB4 Heavy Duty

More information

Model S1F. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW

Model S1F. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model S1F Metallic Design Level 1 ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW

More information

Model G30. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Natural Gas-Operated Diaphragm Pumps.

Model G30. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Natural Gas-Operated Diaphragm Pumps. SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model G30 Metallic Design Level 1 Natural Gas-Operated Diaphragm Pumps 1: PUMP SPECS 2: INSTAL & OP Quality System ISO 9001 Certified

More information

Model S20. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW

Model S20. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model S20 Metallic Design Level 1 1: PUMP SPECS 2: INSTAL & OP Quality System ISO 9001 Certified Environmental Management System ISO 14001

More information

Model S05. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW

Model S05. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW Certified Quality 3/8" NPT AIR EXHAUST 1.42 36.12 SUCTION PORT(OPTIONAL) 1/2" NPT 6.90 175.13 SERVICE & OPERATING MANUAL Original Instructions ISO 9001 Certified ISO 14001 Certified 1.76 44.61 3.12 79.12

More information

Model S1F. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW

Model S1F. SERVICE & OPERATING MANUAL Original Instructions. Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model S1F Metallic Design Level 1 Quality System ISO 9001 Certified Environmental Management System ISO 14001 Certified 5: WET END 3:

More information

Model T15. SERVICE & OPERATING MANUAL Original Instructions. Food Processing Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP

Model T15. SERVICE & OPERATING MANUAL Original Instructions. Food Processing Metallic Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model T15 Food Processing Metallic Design Level 1 ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 3: EXP VIEW 1: PUMP SPECS

More information

Model TSA2. SERVICE & OPERATING MANUAL Original Instructions. Design Level 5. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW 4: AIR END

Model TSA2. SERVICE & OPERATING MANUAL Original Instructions. Design Level 5. Certified Quality 1: PUMP SPECS 2: INSTAL & OP 3: EXP VIEW 4: AIR END SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model TSA2 Design Level 5 ISO 9001 Certified ISO 14001 Certified 5: WET END 4: AIR END 3: EXP VIEW 1: PUMP SPECS 2: INSTAL & OP Warren

More information

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

Versa-Matic. Operating Manual. 3/8 Bolted Plastic Pumps. Polypropylene Kynar Versa-Matic Operating Manual 3/8" Bolted Plastic Pumps Polypropylene Kynar E8 SAFETY WARNINGS Read these instructions completely before installation and start-up. It is the responsibility of the purchaser

More information

II 2G c T5 II 2D c T100

II 2G c T5 II 2D c T100 II 2G c T5 II 2D c T100 SERVICE AND OPERATING MANUAL Model SSB2-A USDA-Accepted Meat & Poultry Type 3 Table of Contents Principle of Operation... 1 Installation and Start-Up... 1 Air Supply... 1 Air Inlet

More information