Distributed Low-Voltage Power System

Size: px
Start display at page:

Download "Distributed Low-Voltage Power System"

Transcription

1 How to use the time clock input on the DLVP Low-Voltage Power Module IS # Distributed Low-Voltage Power System Overview The DLVP power module provides an onboard time clock input, that can be used to control lighting normally or implement partial on/ partial off controls. The power module provides inputs for an external dry contact closure. Time clock commands can be sent to the power module via dry contact input. The table below defines the system actions based on various input conditions and settings. DLVP Time Clock / Occupancy State Time Clock Status Settings Space Condition Open (After hours) Closed (Business Hours) Alert Mode Closed Alert Mode Open Mode (DIP-1) Occupancy (0) Occupancy (0) Vacancy (V) Occupancy (0) Occupancy (0) Vacancy (V) Partial On (DIP-2) Occupied Unoccupied o Sensor Disabled () Lights: Scene 6 Enabled (Y) Lights: 50% Lights: Manual O Disabled () Lights: Scene 6 Enabled (Y) Lights: 50% Lights: Manual O Lights: OFF Receptacles: Off (30-sec after Lights) Lights: OFF Receptacles: OFF (30-sec after Lights) Lights: OFF Receptacles: OFF (30-sec after Lights) Lights: Scene 5 Lights: Scene 5 Lights: Scene 5 Lights: 5-min Blink-warn OFF (Manual O 1-hour) Receptacles: OFF (30-sec after Lights) Lights: 5-min Blink-warn OFF (Manual O 1-hour) Receptacles: OFF (30-sec after Lights) Lights: 5-min Blink-warn OFF (Manual O 1-hour) Receptacles: OFF (30-sec after Lights) Lights: Scene 5 Lights: Scene 5 Lights: Scene 5 All light fixtures are FULL O. Receptacle switchpack turns OFF. Wallstation, occupancy, daylight controls, demand response, and handheld remotes are disabled. System is returned to normal function leaving lighting in previous state. If the previous state is OFF, lighting will initiate a blink warn sequence and turn OFF five minutes later.

2 Time Clock Wiring Connect the dry contact closure to the appropriate terminal for the application. The terminal block is removable for ease of wiring. Use 18 AWG unshielded, 2 conductor twisted pair wiring for connection. Maximum distance must not exceed 1000ft. (300m). LOW HIGH TRIM DEMAD + - CLOCK + - ALERT + - ote: time clock contact closer source may be simple time clocks, lighting control panels, etc. ote: DLVP does not support time sweeps Time Clock Settings The DLVP system may behave differently based on time clock input (during or after business hours) and settings established by switches on the low-voltage power module. Occ / Vac Partial On Select Occ Occ Share Occ / Vac Partial On Select Occ Occ Share Occ / Vac Partial On Select Occ Occ Share V Y O Y Y V Y O Y Y V Y O Y Y Occupancy Mode Partial O disabled Occupancy Mode Partial O enabled Vacancy Mode Partial O /A 2

3 How time clock functions work Out of the box, the time clock contact closure is open (after hours mode) and the system is in vacancy mode. LOW HIGH TRIM Occ / Vac Partial On Select Occ Occ Share V Y Y Y DEMAD + - CLOCK + - ALERT + - O 1 1 REC 3

4 Occupancy mode, Time clock open When the space becomes occupied, receptacles become energized and lighting transitions to Scene 6 (default = 100%) A user may manually change the light level in the space through a wall station or personal remote (LVHH-02) When the space becomes unoccupied, light levels fade to off after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. 4

5 Occupancy mode, partial O enabled, Time clock open When the space becomes occupied, receptacles become energized and lighting transitions to the partial O level (50%) A user may manually change the light level in the space through a wall station or personal remote (LVHH-02) When the space becomes unoccupied, light levels fade to off after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. 5

6 Vacancy mode, Time clock open When the space becomes occupied, receptacles become energized, however lighting will remain OFF until a manual action occurs A user may manually select the light level in the space through a wall station or personal remote (LVHH-02) When the space becomes unoccupied, light levels fade to off after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. 6

7 Occupancy mode, Time clock closed When the space becomes occupied, receptacles become energized and lighting transitions to Scene 6 (default = 100%) A user may manually change the light level in the space through a wall station or personal remote (LVHH-02) When the space becomes unoccupied, light levels fade to Scene 5 (default = 20%) providing partial OFF functionality 7

8 Vacancy mode, Time clock closed When the space becomes occupied, receptacles become energized, however lighting will remain OFF until a manual action occurs A user may manually select the light level in the space through a wall station or personal remote (LVHH-02) When the space becomes unoccupied, light levels fade to off after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. 8

9 Example Full day, occupancy mode Time clock contact OPE with no occupancy, the lighting is OFF and receptacles are de-energized. The business day begins (time clock contact CLOSED), receptacles are energized and lighting fades to Scene 5 (default = 20%) The space becomes occupied, lighting transitions to Scene 6 (default = 100%) The space becomes unoccupied, light levels fade to Scene 5 (default = 20%) after the sensor delay time expires, providing partial OFF functionality The space becomes occupied, lighting transitions to Scene 6 (default = 100%) The business day ends (time clock contact OPE), no changes are immediately noticed with lighting or receptacles The space becomes unoccupied, light levels fade to OFF after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. The space becomes occupied after hours, receptacles are energized and lighting fades to Scene 6 (default = 100%) The space becomes unoccupied for the remainder of the time clock open (after hours) period, light levels fade to OFF after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. 9

10 Example Full day, occupancy mode with partial O enabled Time clock contact OPE with no occupancy, the lighting is OFF and receptacles are de-energized. The business day begins (time clock contact CLOSED), receptacles are energized and lighting transitions to Scene 5 (default = 20%) The space becomes occupied, lighting fades to the partial O level (50%) A user manually changes the light level in the space through a wall station or personal remote (LVHH-02) The space becomes unoccupied, light levels fade to Scene 5 (default = 20%) after the sensor delay time expires The space becomes occupied, lighting transitions to the partial O level (50%) A user manually changes the light level in the space through a wall station or personal remote (LVHH-02) The business day ends (time clock contact OPE), no changes are immediately noticed with lighting or receptacles The space becomes unoccupied, light levels fade to OFF after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. The space becomes occupied after hours, receptacles become energized and lighting fades to the partial O level (50%) The space becomes unoccupied for the remainder of the time clock open (after hours) period, light levels fade to OFF after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. 10

11 Example Full day, vacancy mode Time clock contact OPE with no occupancy, the lighting is OFF and receptacles are de-energized. The business day begins (time clock contact CLOSED), receptacles are energized and lighting transitions to Scene 5 (default = 20%) The space becomes occupied, however lighting will remain at Scene 5 until a manual action occurs A user manually select the light level through a wall station or personal remote (LVHH-02) The space becomes unoccupied, light levels fade to Scene 5 after the sensor delay time expires The space becomes occupied, however lighting will remain at Scene 5 until a manual action occurs A user manually changes the light level through a wall station or personal remote (LVHH-02) The business day ends (time clock contact OPE), no changes are immediately noticed with lighting or receptacles The space becomes unoccupied, light levels fade to OFF after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. The space becomes occupied after hours, receptacles become energized, however lighting will remain OFF until a manual action occurs A user manually changes the light level through a wall station or personal remote (LVHH-02) The space becomes unoccupied for the remainder of the time clock open (after hours) period, light levels fade to OFF after the sensor delay time expires. Receptacle are de-energized 30-seconds after lighting turns off. 11

12 Example Full day, o motion sensors Time clock contact OPE with no occupancy, the lighting is OFF and receptacles are de-energized. The business day begins (time clock contact CLOSED), receptacles are energized and lighting transitions to Scene 5 (default = 20%) The space becomes occupied, however lighting will remain at Scene 5 until a manual action occurs A user manually select the light level through a wall station As the business day ends (time clock contact OPE), the lighting will blink five minutes prior to automatically turning OFF A user may delay the automatic OFF by one hour by manually pressing a button on a wall station Lighting fades to off either by manually pressing a button on a wall station or personal remote (LVHH-02). Receptacle are de-energized 30-seconds after lighting turns off. The space becomes occupied after hours, however lighting will remain OFF and receptacles de-energized until a manual action occurs A user manually changes the light level through a wall station providing the requested light level for one hour (receptacles become energized) The one hour lighting period may be extended by a manual action (lighting will blink five minutes prior to automatically turning OFF) Lighting fades to off either by manually pressing a button on a wall station or allowing the automatic OFF to occur. Receptacle are de-energized 30-seconds after the one hour lighting period ends Eaton 1121 Highway 74 South Peachtree City, GA For service or technical assistance: Canada Sales 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: F: Eaton All Rights Reserved Printed in USA Publication o. IB503015E December 6, 2017 Eaton is a registered trademark. All trademarks are property of their respective owners. Procuct availability, specifications, and compliances are subject to change without notice.

FR Series Premium Commercial LED Luminaire

FR Series Premium Commercial LED Luminaire FR Series Premium Commercial LED Luminaire FR Premium Commercial LED Luminaire Aesthetics, performance, value. The FR series is a premium commercial luminaire offering an excellent connected lighting solution

More information

Excel 10 W7751H SMART VAV ACTUATOR BEFORE INSTALLATION INSTALLATION

Excel 10 W7751H SMART VAV ACTUATOR BEFORE INSTALLATION INSTALLATION Excel 10 W7751H SMART VAV ACTUATOR BEFORE INSTALLATION The W7751H Smart VAV Actuator is a factory-combined Excel 10 Variable Air Volume (VAV) Box Controller and an ML6161B Direct-Coupled Actuator with

More information

HBDB High Bay Fixture with Occupancy Sensor

HBDB High Bay Fixture with Occupancy Sensor HBDB High Bay Fixture with Occupancy Sensor INSTALLATION INSTRUCTIONS The High Bay Luminaire is ideal for installations with mounting heights over 20 feet. The fixture can be mounted with a hook or pendant

More information

16A & 32A IEC 309 Watertight pin & sleeve devices

16A & 32A IEC 309 Watertight pin & sleeve devices Technical Data IEC 309 Product Description - International ; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding AH416R6W AH416C6W AH416P6W Pin & sleeve plugs features & benefits

More information

Industrial grade 20A Non-NEMA locking devices

Industrial grade 20A Non-NEMA locking devices Technical Data Non-NEMA locking devices Description, 125/250V/AC, 3P-3W W X X W 9965C 7314C Y Receptacle Plug Non-NEMA Y Design features for plug & connector All nylon construction EPDM gasket seals cord

More information

60A & 100A IEC 309 Watertight pin & sleeve devices

60A & 100A IEC 309 Watertight pin & sleeve devices Technical Data AH560R7W AH560C9W IP69K certified AH560P9W AH560B9W Product Description - North American 60A & 100A; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding Pin & sleeve

More information

ArcLine Recessed LED luminaire

ArcLine Recessed LED luminaire ArcLine Recessed LED luminaire ArcLine Recessed LED luminaire The ArcLine LED Series blends modern styling with an innovative optical design to deliver leading-edge performance and energy savings. ArcLine

More information

Industrial grade 30A Non-NEMA locking devices

Industrial grade 30A Non-NEMA locking devices Technical Data Non-NEMA locking devices Description, 3ØY 120/208V/AC, 4P-4W X X W Y Y W AH3431N AH3430 AH3433N AH3436N Z Receptacle Plug Non-NEMA Design features for plug & connector construction Z EPDM

More information

VisionPRO 8000 Thermostats

VisionPRO 8000 Thermostats VisionPRO 8000 Thermostats INSTALLER SETUP AND SYSTEM TEST POCKET GUIDE 62-0266 INSTALLER SETUP 1. Press SYSTEM. FAN ON AUTO Inside SYSTEM HEAT AM SCHED HOLD M24079 2. Press and hold these two blank buttons

More information

60A & 100A IEC 309 Watertight pin & sleeve devices

60A & 100A IEC 309 Watertight pin & sleeve devices Technical Data AH560R7W AH560C9W IP69K certified AH560P9W AH560B9W Product Description - North American 60A & 100A; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding Pin & sleeve

More information

Cruze Recessed LED luminaire

Cruze Recessed LED luminaire Cruze Recessed LED luminaire Cruze Recessed LED Luminaire Performance, style, affordability. The Cruze LED combines contemporary styling and optimal illumination design with the technology of Eaton's Linear

More information

Excel 10 W7751J Smart VAV Actuator

Excel 10 W7751J Smart VAV Actuator Excel 0 W775J Smart VAV Actuator INSTALLATION INSTRUCTIONS BEFORE INSTALLATION The W775J Smart VAV Actuator is a factory-combined Excel 0 Variable Air Volume (VAV) Box Controller and an ML66B Direct-Coupled

More information

Excel 10 W7751J Smart VAV Actuator

Excel 10 W7751J Smart VAV Actuator Excel 0 W775J Smart VAV Actuator BEFORE INSTALLATION INSTALLATION INSTRUCTIONS The W775J Smart VAV Actuator is a factory-combined Excel 0 Variable Air Volume (VAV) Box Controller and an ML66B Direct-Coupled

More information

RDG160TU Commercial Thermostat

RDG160TU Commercial Thermostat Document No. 129-588 RDG160TU Commercial Thermostat Selecting Location Install the thermostat about 4 feet (120 cm) above the floor on an inside wall. Ensure that there is free airflow around the thermostat.

More information

Arrow Hart hospital grade GFCI modular receptacles

Arrow Hart hospital grade GFCI modular receptacles Technical Data Arrow Hart hospital grade GFCI Description 2-pole, 3-wire grounding 15A 125V/AC 20A 125V/AC TAMPER RESISTANT SGFH20_MOD Design features ArrowLink modular plug and connector incorporate a

More information

Encounter Recessed LED luminaire

Encounter Recessed LED luminaire Recessed LED luminaire Patented AccuAim optics Recessed LED luminires Highly efficient luminous panel Performance, uniformity, style. The Series redefines ambient lighting by blending contemporary styling

More information

HU20 Undercabinet lighting

HU20 Undercabinet lighting HU20 Undercabinet lighting HU20 Magnetic Puck LED Undercabinet Halo introduces the next generation of HU20 to address your LED Undercabinet and task lighting needs. Ideal for task, accent, office, cove,

More information

Encounter Metric Recessed LED Luminaire

Encounter Metric Recessed LED Luminaire Recessed LED Luminaire Performance, uniformity, style. The Encounter Metric Series redefines ambient lighting by blending contemporary styling with innovative WaveStream LED technology. The result is exceptional

More information

TRBR20WBXSP 20A TR Comm WH Dup Rec. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight.

TRBR20WBXSP 20A TR Comm WH Dup Rec. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRBR20WBXSP 20A TR Comm WH Dup Rec Eaton Wiring Devices Catalog Number Manufacturer Weight per unit Product Category Features

More information

20A & 30A IEC 309 Watertight pin & sleeve devices

20A & 30A IEC 309 Watertight pin & sleeve devices AH430R7W AH430C7W IP69K certified AH430P7W Product Description - North American 20A & 30A; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding Pin & sleeve plugs features & benefits

More information

Cruze Recessed LED Luminaire

Cruze Recessed LED Luminaire Cruze Recessed LED Luminaire Performance, style, affordability. The Cruze LED combines contemporary styling and optimal illumination design with the technology of Eaton's Linear LED Platform. Its high

More information

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18 Zone Sensors Submittal Data English Language/IP Units SD1582EW 06/18 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and

More information

Motorized Electric Latch Retraction

Motorized Electric Latch Retraction ; SECTION I: OVERVIEW 1. Description The Corbin Russwin MELR Electric Latch Retraction (ELR), refer to Figure 1, works with ED4000 & ED5000 Series exit devices to provide remote-controlled latch retraction

More information

Power Supplies DORMA PS

Power Supplies DORMA PS Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed

More information

Excel 10 W7751H3007 VAV ACTUATOR

Excel 10 W7751H3007 VAV ACTUATOR HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION The Smart VAV Actuator consists of a factorycombined variable air volume (VAV) box controller and a direct-coupled damper actuator with de-clutch mechanism.

More information

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER UHC 300 22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER OVERVIEW The HVAC building automation controls market requires a DDC controller that provides scalable, consolidated control in a fully programmable,

More information

Industrial grade L20-30 locking devices

Industrial grade L20-30 locking devices Technical Data L20-30 locking devices Description AHL2030P AHL2030R AHL2030C AHL2030FO Design features for plug & connector All nylon construction EPDM gasket seals cord hole from dust and debris Back

More information

Performance Summary. Product Description. Adjustable High and Low Modes High: 0 to 10V; Low: off to 9.8V

Performance Summary. Product Description. Adjustable High and Low Modes High: 0 to 10V; Low: off to 9.8V For use with Cree Edge Series, 304 Series, 228 Series, CPY Series, OSQ Series, VG Series, IG Series, and OSQ-HO Series Luminaires Performance Summary Adjustable High and Low Modes High: 0 to 10V; Low:

More information

Arrow Hart industrial grade power lock plugs, connectors and receptacles

Arrow Hart industrial grade power lock plugs, connectors and receptacles Arrow Hart industrial grade power lock plugs, connectors and s Description 2-pole, 3-wire grounding 3-pole, 3-wire non-grounding 3-pole, 4-wire grounding 20A, 125V/AC; 20A, 250V/DC; 30A, 480V/AC; 30A,

More information

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication

More information

Industrial LED luminaires Exit and Emergency

Industrial LED luminaires Exit and Emergency Industrial LED luminaires Exit and Emergency SEL/SELM Indoor WAREHOUSE / DISTRIBUTION MANUFACTURING GYMNASIUMS / MULTI-PURPOSE ROOMS / ATHLETIC CENTER SEL BIG BOX / RETAIL SELM Polycarbonate Metal 12-7/8"

More information

RSA-MRZ Installation Instructions

RSA-MRZ Installation Instructions IL511001EN Brand Logo reversed black out of INS # RSA-MRZ Installation Instructions IMPORTANT: Read carefully before installing fixture. Retain for future reference. WARNING Risk of Electric Shock Disconnect

More information

Paralleling Equipment

Paralleling Equipment Paralleling Equipment PowerCommand Model 300 Digital Master Control Description The PowerCommand TM Digital MasterControl is a microprocessor-based paralleling system component, designed to directly interface

More information

Sapling 2-Wire Digital Communication System Line Drawing

Sapling 2-Wire Digital Communication System Line Drawing Sapling 2-Wire Digital Communication System Line Drawing Single Configuration A - Small 2-Wire Clock System using one converter box on a single clock run. 24 Volt (5.5 Amp max.) Power & Secondary Clocks

More information

Flotection: Building Main Shutoff System

Flotection: Building Main Shutoff System Flotection: Building Main Shutoff System Overview of System Retail stores have a requirement for night time monitoring of the Domestic Water Supply. When flow is detected, during the hours the store is

More information

Industrial grade L22-30 locking devices

Industrial grade L22-30 locking devices Technical Data L22-30 locking devices Description AHL2230P AHL2230R AHL2230C AHL2230FO Design features for plugs & connectors All nylon construction EPDM gasket seals cord hole from dust and debris Back

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS FOR SPACESAVER POWER ASSIST CONTROLS SYSTEM PREPARED FOR: SPACESAVER ORDER NUMBER: P A G E ONE TOUCH - MANUAL RESET... 2 A/B ELECTRO - MECHANICAL SWEEP... 3 DUAL ELECTRO - MECHANICAL

More information

HBLEDLD524SEWUNV Hbledld524sewunvl850ed2u

HBLEDLD524SEWUNV Hbledld524sewunvl850ed2u 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HBLEDLD54SEWUNV Hbledld54sewunvl850edu Catalog Number HBLEDLD54SEWUNV Manufacturer Description Wide Distribution, 4, 000

More information

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 STANDARD OPERATION MODE 4 HOW TO CONTROL AND SHARE MULTIPLE S 5 TRANSMITTER FUNCTION SWITCH SETTINGS 6 OPERATING THE TEST BEACON 7 OPERATING

More information

Industrial grade L5-30 locking devices

Industrial grade L5-30 locking devices Technical Data L5-30 locking devices Description AHL530P AHL530R AHL530C AHL530FO Design features for plugs & connector All nylon construction EPDM gasket seals cord hole from dust and debris Back wire

More information

Flight Systems. Replacement for KASSEC DESCRIPTION

Flight Systems.   Replacement for KASSEC DESCRIPTION DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most

More information

Industrial grade L6-30 locking devices

Industrial grade L6-30 locking devices Technical Data Industrial grade L6-30 locking devices Description AHL630P AHL630R AHL630C AHL630FO Design features for plug & connector All nylon construction EPDM gasket seals cord hole from dust and

More information

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual Series 70 Operation and Maintenance Manual TABLE OF CONTENTS 1. Definition of Terms............................................. 1 2. Safety................................................... 1 3. Storage..................................................

More information

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010 INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODELS 201A 201A-9 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605) 348-5685 BE SURE POWER

More information

Premium industrial grade isolated ground straight blade receptacles

Premium industrial grade isolated ground straight blade receptacles Technical Data Description 2-Pole, 3-Wire Grounding 15A 125V; 15A 250V 20A 125V; 20A 250V NEMA 5-15, 5-20, 6-15, 6-20 IG5261 AHIG5362 Design features Exclusive screw terminal guards provide fast, easy

More information

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14 Zone Sensors Submittal Data English Language/IP Units SD1582EW 10/14 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and

More information

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and pushbutton setpoint adjustment. Additional options include pushbutton override, fan

More information

24SRLD248CUNVL84 2X4 Led Layin 40K 4800LM

24SRLD248CUNVL84 2X4 Led Layin 40K 4800LM 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 24SRLD248CUNVL84 2X4 Led Layin 40K 4800LM Catalog Number 24SRLD248CUNVL84 Manufacturer Description Led, 2'X4' Skyridge,

More information

YCCS TE-6800 Series Temperature Sensors

YCCS TE-6800 Series Temperature Sensors YCCS TE-6800 Series Temperature Sensors TE-68xx-xNN0S Installation Instructions 85-YIM-B-070 Applications The York Commercial Comfort System (YCCS) TE-68xx-xNN0S Series Temperature Sensors provide temperature

More information

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 6352WBU 20A-125V DPLX RCPT Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product Category

More information

Hart lock industrial grade 50A locking devices

Hart lock industrial grade 50A locking devices Technical Data Hart lock industrial grade 50A locking devices 3-pole, 4-wire grounding 50A, 125/250V/AC, 3Ø, 250V/AC Non-NEMA, California standard X W G G W X Receptacle Plug CS6365EX Design features for

More information

Industrial grade L14-30 locking devices

Industrial grade L14-30 locking devices Description AHL1430P AHL1430R AHL1430C AHL1430FO Design features for plug & connector All nylon construction EPDM gasket seals cord hole from dust and debris Back wire terminal clamps for easy secure wiring

More information

Industrial grade L15-30 locking devices

Industrial grade L15-30 locking devices Technical Data Industrial grade L15-30 locking devices Description AHL1530P AHL1530R AHL1530C AHL1530FO Design features for plug & connector All nylon construction EPDM gasket seals cord hole from dust

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

2904 Power Supply Installation Instructions I-EA00041

2904 Power Supply Installation Instructions I-EA00041 FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and

More information

Recp Duplex 20A 250V 2P3W STR Swire WH

Recp Duplex 20A 250V 2P3W STR Swire WH 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 815WB0X Recp Duplex 20A 250V 2P3W STR Swire WH Eaton Wiring Devices Catalog Number Manufacturer Description Weight per

More information

RSA-MRZ Installation Instructions

RSA-MRZ Installation Instructions IL511001EN Brand Logo reversed black out of INS # RSA-MRZ Installation Instructions IMPORTANT: Read carefully before installing fixture. Retain for future reference. WARNING Risk of Electric Shock Disconnect

More information

MCD Pump Application Module

MCD Pump Application Module Overview The Pump Application Module expands the soft starter's input and output functionality and is ideal for applications where greater control and feedback are required. The module provides three digital

More information

Commercial grade straight blade receptacles

Commercial grade straight blade receptacles Technical Data Description 2-Pole, 3-Wire Grounding 15A 125V/AC; 15A 250V/AC 20A 125V/AC; 20A 250V/AC NEMA 5-15, 5-20, 6-15, 6-20 Design features Galvanized steel, wrap-around yoke mounting strap for superior

More information

CB-9 CONTROL BOARD INSTRUCTION MANUAL

CB-9 CONTROL BOARD INSTRUCTION MANUAL CB-9 CONTROL BOARD INSTRUCTION MANUAL AUGUST 95 The CB-9 control board is designed to automate 1 or 2 A.T.A swing gate or sliding gate drive units. This instruction manual gives detailed instructions on

More information

5700 SERIES Low Energy Power Operator

5700 SERIES Low Energy Power Operator Low Energy Power Operator introduction Low energy door operators were once considered a necessity only for those with physical challenges. Today, due to the population s busy lifestyles, the convenience

More information

MaxLite LED Medium Area Light

MaxLite LED Medium Area Light General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Operations Manual. Zero Speed Switch Sensor Model ZS09P Zero Speed Switch Sensor Model ZS09P The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The Phares Electronics Model ZS09P

More information

Luminous HE 282/284 Direct ambient lighting. Neoray. Possibilities of Light

Luminous HE 282/284 Direct ambient lighting. Neoray. Possibilities of Light Luminous HE 282/284 Direct ambient lighting Neoray Possibilities of Light Luminous HE 282/284 Luminous HE: A high efficiency volumetric recessed ambient luminaire with bold recessed acrylic diffusers providing

More information

Excel 10 W7751H Smart VAV Actuator

Excel 10 W7751H Smart VAV Actuator Excel 0 W775H Smart VAV Actuator INSTALLATION INSTRUCTIONS BEFORE INSTALLATION The W775H Smart VAV Actuator is a factory-combined Excel 0 Variable Air Volume (VAV) Box Controller and an ML674 Direct-Coupled

More information

PRODUCT INFORMATION BULLETIN

PRODUCT INFORMATION BULLETIN 724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery

More information

CDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications

CDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications CDI series Model TW Residential to Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options and Control Options Standard Features White Pre-Painted Sheet

More information

Requirements document for a parking garage control system

Requirements document for a parking garage control system Requirements document for a parking garage control system August 5, 1996 Contents 1 Introduction 2 1.1 Purpose : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 2 1.2 Scope

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

SeleCCTable LED Direct Mount Collection. RL Recessed Downlight. Direct Mount

SeleCCTable LED Direct Mount Collection. RL Recessed Downlight. Direct Mount SeleCCTable LED Direct Mount Collection RL Recessed Downlight Direct Mount HALO SeleCCTable Family 2700K 3000K 3500K 4000K 5000K RL-DM SeleCCTable Series RL4069S1EWHDM 4 LED Retrofit Baffle-Trim, Direct

More information

SkyBar TM Series High Bay LED Luminaire

SkyBar TM Series High Bay LED Luminaire SkyBar TM Series High Bay LED Luminaire Patented AccuAim TM optics Precisely controlled light output Design Freedom Optical Control Energy Efficiency Brightness Control Mainstream Value The Breakthrough

More information

4750 Recp Duplex 15A 277V 2P3W H/L BK. Features amperage rating. Description RECP DUPLEX 15A 277V 2P3W H/L BK

4750 Recp Duplex 15A 277V 2P3W H/L BK. Features amperage rating. Description RECP DUPLEX 15A 277V 2P3W H/L BK 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4750 Recp Duplex 15A 277V 2P3W H/L BK Eaton Wiring Devices Catalog Number 4750 Manufacturer Eaton Wiring Devices Description

More information

SE8300 Series Installation Guide 24 Vac Low Voltage

SE8300 Series Installation Guide 24 Vac Low Voltage Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification

More information

A419ABG-3C Electronic Temperature Control

A419ABG-3C Electronic Temperature Control Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where

More information

Installation Instructions Shaper 1800 aircraft cable installation

Installation Instructions Shaper 1800 aircraft cable installation IL525014N INS #Shaper RLM Shade/ Shape DOME Shade/ Shape Make Certain Power is OFF before starting installation or attempting any maintenance. Risk of Fire/Electric Shock. If not qualified, consult an

More information

TDX - Taco Duplex Starter with

TDX - Taco Duplex Starter with Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload

More information

PathLinx Series LED Emergency Lighting

PathLinx Series LED Emergency Lighting PathLinx Series LED Emergency Lighting Emergency Lighting LEMRO LED Emergency Light with Rotatable Optics Features Aesthetic, compact, thin profile design blends into commercial spaces AccuLED adjustable

More information

Industrial grade L15-20 locking devices

Industrial grade L15-20 locking devices Description AHL1520P AHL1520R AHL1520C AHL1520FO Design features for plugs & connectors All nylon construction EPDM gasket seals cord hole from dust and debris Back wire terminal clamps for easy secure

More information

Adaptive Power Module

Adaptive Power Module N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive

More information

Adaptive Power Module

Adaptive Power Module N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive

More information

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Single or Double 240VAC motor control for domestic and industrial gates and doors. COBO30 Double 240V Motor Drive Controller Features For 240Volt Motors Auto Closing Open Only Security Closing and Extended Lock Pulse (user selectable) Travel Timer Push Button Input Photo Cell Input Option

More information

Commercial grade straight blade duplex receptacles

Commercial grade straight blade duplex receptacles Description 2-Pole, 3-Wire Grounding 15A 125V/AC; 15A 250V/AC 20A 125V/AC; 20A 250V/AC NEMA 5-15, 5-20, 6-15, 6-20 BR15 Design features Galvanized steel, wrap-around yoke mounting strap for superior assembly

More information

Catalog # Project. Comments. Prepared by. L653 L =12'Nominal Actual length: 140-1/8" [3559mm] W=1 3/8" [3559mm] H =11/16" [17.5mm]

Catalog # Project. Comments. Prepared by. L653 L =12'Nominal Actual length: 140-1/8 [3559mm] W=1 3/8 [3559mm] H =11/16 [17.5mm] Miniature size, decorator finishes, push-in connectors, economy, all combine to make single-circuit Miniature Trac perfect for residential or commercial use. Polarized connectors and end caps are molded

More information

Installation Instructions

Installation Instructions BZ-200, BZ-250, BZ-250-347 Power Pack Auto/Manual Mode Switch BZ-250, BZ-250-347 only SPECIFICATIONS Voltages BZ-200, BZ-250... 120 277 VAC, 50/60 Hz, single phase BZ-250-347... 120 347 VAC, 50/60 Hz,

More information

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates. Programmable Control board for wings gates www.remotecontrolgates.co.uk Manual for installation Compatible from firmware version BIOS2BT02 CONTROL UNIT BIOS2 1. Introduzione The control unit BIOS2 is particularly

More information

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/ :33 AM

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/ :33 AM Page 1 of 7 Caterpillar Electronic Technician 2012A v1.0 Product Status Report 10:33 AM Product Status Report Product ID Comments Unavailable Soft-Switch Panel ECM Part Number 2437068-00 Software Group

More information

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC APPLICATION GUIDE Simplicity LINC GATEWAY OVERVIEW The Simplicity LINC Gateway operates as a Modbus Client providing an interface between a MS/TP control system and devices that communicate using the Modbus

More information

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual Your Global Flow Control Partner Series 70 Table of Contents 1. Definition of Terms.......................................2 2. Safety............................................. 2 3. Storage............................................2

More information

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3.

MANUAL INSTALLATION. Tracking Controller. TC Series. v100 Issue Date: 02/25/ Price Industries Limited. All rights reserved. Firmware: 1.3. MANUAL INSTALLATION Tracking Controller TC Series v100 Issue Date: 02/25/16 2016 Price Industries Limited. All rights reserved. Firmware: 1.3.0 TABLE OF CONTENTS Product Overview General...1 Tracking Controller

More information

Premium industrial grade straight blade receptacles

Premium industrial grade straight blade receptacles Technical Data Description 2-Pole, 3-Wire Grounding 15A 125V; 15A 250V 20A 125V; 20A 250V NEMA 5-15, 5-20, 6-15, 6-20 AH5262 AH5362 Design features Exclusive screw terminal guards provide fast, easy insulation

More information

BZ-150. Installation Instructions. Power Pack SPECIFICATIONS

BZ-150. Installation Instructions. Power Pack SPECIFICATIONS SPECIFICATIS Voltages...120/. 50/60Hz Load Requirements Ballast... 20amp @120/ Incandescent... 20amp @ Motor... 1HP @120/240VAC Output...225mA @ (with relay connected) Input Control... 12- Hold... 12-

More information

Switches Unlimited Contact: Phone: * Fax:

Switches Unlimited Contact: Phone: * Fax: Phone: 00-221-047 * Fax: 71-672-6370 Page -2 Page -3 SIGNAL TOWERS Signal towers Ø70mm Steady, blinking light or flash modules Pulsed or continuous sound modules Incandescent and LED bulbs. SIGNAL BEACONS

More information

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N R SERVICE MANUAL 50 AMP SMART EMS 50 Amp EMS Display Panel P/N 00-00684-000 LINE 1 LINE 2 6 5 4 3 2 1 6 5 4 3 2 1 M M 1 2 3 4 5 6 A I N A I N INVERTER LOADS SUBPANEL DANGER: HAZARD OF ELECTRICAL SHOCK

More information

Digital Room Thermostats with Touch Screen LCD

Digital Room Thermostats with Touch Screen LCD TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

SeleCCTable LED Direct Mount Collection

SeleCCTable LED Direct Mount Collection SeleCCTable LED Direct Mount Collection HLB Ultra-thin Recessed Downlight HALO HLB ultra-thin The HLB is an ultra-thin LED lens downlight with a remote driver / junction box ideal for new construction

More information

BAPI-Stat 3 Room Sensor

BAPI-Stat 3 Room Sensor Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read

More information

Setting Up an Oscillation Amplitude Sweep Test

Setting Up an Oscillation Amplitude Sweep Test Setting Up an Oscillation Amplitude Sweep Test 6. Select an Oscillation Amplitude test. 8. Enter the Soak time to allow for temperature equilibration. ( A ten-minute soak time is 9. Enter the Frequency

More information

INSTALLATION/OPERATING INSTRUCTIONS VSP. A Variable Speed Pump Control

INSTALLATION/OPERATING INSTRUCTIONS VSP. A Variable Speed Pump Control INSTALLATION/OPERATING INSTRUCTIONS VSP A Variable Speed Pump Control The VSP is a hydronic heating control. The temperature of the heating water is controlled by regulating the speed of a pump which injects

More information

50 AMP Smart Energy Management System Model 900 INSTALLATION & SERVICE MANUAL 50 AMP SMART EMS

50 AMP Smart Energy Management System Model 900 INSTALLATION & SERVICE MANUAL 50 AMP SMART EMS R 50 AMP SMART EMS 50 Amp EMS Display Panel P/N 00-00903-050 (Ivory) P/N 00-00903-150 (Black) LINE 1 LINE 2 6 5 4 3 2 1 M M 1 2 3 4 5 6 A A I I N N DANGER: HAZARD OF ELECTRICAL SHOCK OR BURN. TURN OFF

More information