LA400 & LA400-S O W N E R ' S M A N U A L MEDIUM DUTY SWING GATE OPERATOR. Large Metal Control Box (XLM) Optional 2 YEAR WARRANTY

Size: px
Start display at page:

Download "LA400 & LA400-S O W N E R ' S M A N U A L MEDIUM DUTY SWING GATE OPERATOR. Large Metal Control Box (XLM) Optional 2 YEAR WARRANTY"

Transcription

1 LA400 & LA400-S MEDIUM DUTY SWING GATE OPERATOR O W N E R ' S M A N U A L Large Metal Control Box (XLM) Optional Serial # Primary Arm Serial # Secondary Arm Serial # Control Box Installation Date The LA400 is intended for use with vehicular swing gates. The operator can be used in Class I, Class II and Class III applications. YEAR WARRANTY Radio Receiver Built on Board 5 MHz

2 TABLE OF CONTENTS SAFETY -6 Safety Symbol and Signal Word Review UL5 Model Classifications Safety Installation Information Gate Construction Information 4 Important Safety Information 5-6 INTRODUCTION 7-8 Operator Specifications 7 Carton Inventory 7 Additional Items Needed for Installation 8 Tools Needed 8 INSTALLATION 9- Overview of Typical Installation 9-0 Check Your Gate Mounting Options Manual Release Determine Position of the Pull-to-Open Bracket Determine Position of the "Optional" Push-to-Open Bracket Assemble Gate Post Bracket (Pull-to-Open) Attach Brackets to Gate Operator Determine Mounting Location 4 Measuring and Marking for the Gate Bracket 4 Position Gate Operator on Gate 5 Test Gate Travel 6 Secure Post Bracket to Gate Post 6 Secure Gate Bracket to Gate 7 Warning Sign Placement 7 Standard Control Box 8-9 Large Metal Control Box (XLM) 0- WIRING -8 Connect the Gate Operator (Gate ) to the Control Box Set the Bipart Delay (Model LA400-S Only) Connect the Gate Operator (Gate ) to the Control Box (Model LA400-S Only) 4 Junction Box (Model LA400-S Only) 5-6 Connect Transformer to Control Board 7 Earth Ground Rod Installation (Optional) 8 Connect Batteries 8 ADJUSTMENT 9- Set DIP Switch 9 Limits 0- Force Adjustment Timer-to-Close PROGRAMMING 4 Remote Controls 4 Keyless Entry 4 Erase All Codes 4 Test 4 ADDITIONAL FEATURES 5-8 DIP Switch Settings 5 Control Inputs 6 Loop Inputs 7 Photo/Edge Inputs (P6-7-8 and 9) 7 Safety Accessories for Secondary Entrapment Protection 8 OPERATION AND MAINTENANCE 9-40 Reset Button 9 Remote Control 9 Manual Release 9 Maintenance 40 TROUBLESHOOTING 4-4 Basic Control Board Layout 4 Wiring Diagram 4 Diagnostic Codes 4 Troubleshooting Chart 4 REPAIR PARTS Control Box 44 Gate Operator Arm 44 How to Order Repair Parts 45 WARRANTY POLICY 45 ACCESSORIES 46 TEMPLATE BACK COVER SAFETY» SAFETY SYMBOL AND SIGNAL WORD REVIEW When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of Serious Injury or Death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. Read them carefully. IMPORTANT TE BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. DO T attempt repair or service of your gate operator unless you are an Authorized Service Technician. MECHANICAL ELECTRICAL

3 SAFETY» UL5 MODEL CLASSIFICATIONS CLASS I RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one to four single family dwellings, or a garage or parking area associated therewith. I CLASS II COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garage, retail store or other building servicing the general public. II CLASS III COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. III SAFETY ACCESSORY SELECTION All UL5 compliant LiftMaster gate operators will accept external entrapment protection devices to protect people from motorized gate systems. UL5 requires that the type of entrapment protection correctly matches each gate application. Below are the four types of entrapment protection systems recognized by UL5 for use on this operator. ENTRAPMENT PROTECTION TYPES Type A: Inherent obstruction sensing system, self-contained within the operator. This system must sense and initiate the reverse of the gate within two seconds of contact with a solid object. Type B: Connections provided for a non-contact device, such as a photoelectric eye can be used as a secondary protection. Type B: Connections provided for a contact sensor. A contact device such as a gate edge can be used for secondary protection. Type E: Built-in audio alarm. Examples include sirens, horns or buzzers. UL5 ENTRAPMENT PROTECTION REQUIREMENTS GATE OPERATOR ENTRAPMENT PROTECTION UL5 Installation CLASS CLASS I CLASS II CLASS III Swing & Gate Barrier (Arm) Operator Primary Type Secondary Type A A, B or B A, B or B A, B, B or E The chart above illustrates the entrapment protection requirements for each of the three UL5 classes. In order to complete a proper installation you must satisfy the entrapment protection chart shown above. That means that the installation must have one primary means of entrapment protection and one independent secondary means of entrapment protection. Both primary and secondary entrapment protection methods must be designed, arranged or configured to protect against entrapments in both the open and close directions of gate travel. For Example: For a slide gate system that is installed on a single-family residence (UL5 Class I) you must provide the following: As your primary type of entrapment protection you must provide Type A inherent (built into the operator) entrapment sensing and at least one of the following as your secondary entrapment protection: Type B- Non-contact sensors such as photoelectric eyes, Type B- Contact sensors such as gate edges. TE: UL requires that all installations must have warning signs placed in plain view on both sides of the gate to warn pedestrians of the dangers of motorized gate systems.

4 SAFETY» SAFETY INSTALLATION INFORMATION. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application.. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce public exposure to potential hazards.. A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every design. Specific safety features include: Gate Edges Guards for Exposed Rollers Photoelectric Sensors Screen Mesh Vertical Posts Instructional and Precautionary Signage 4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate. b. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (. m) above the ground to prevent a -/4 inch (6 cm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. c. All exposed pinch points are eliminated or guarded, and guarding is supplied for exposed rollers. 5. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate. 6. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. 7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. 8. Controls intended for user activation must be located at least 6 feet (.8 m) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. 9. The Stop and/or Reset (if provided separately) must be located in the lineof-sight of the gate. Activation of the reset control shall not cause the operator to start. 0. A minimum of two () WARNING SIGNS shall be installed, one on each side of the gate where easily visible.. For a gate operator utilizing a non-contact sensor: a. Reference owner s manual regarding placement of non-contact sensor for each type of application. b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving. c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.. For a gate operator utilizing a contact sensor such as an edge sensor: a. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate. b. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. c. A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not subject to mechanical damage. d. A wireless contact sensor such as the one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions. e. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (5 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge. f. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).

5 SAFETY» GATE CONSTRUCTION INFORMATION Vehicular gates should be installed in accordance with ASTM F00: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at or GENERAL REQUIREMENTS. Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM F00 for additional gate types.. Gates shall be designed, constructed and installed to not fall over more than 45 degrees from the vertical plane, when a gate is detached from the supporting hardware.. Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches (.7 mm) when other than the exceptions listed in ASTM F00..4 The minimum height for barbed tape shall not be less than 8 feet (.44 m) above grade and for barbed wire shall not be less than 6 feet (.8 m) above grade..5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator..6 A gate latch shall not be installed on an automatically operated gate..7 Protrusions shall not be permitted on any gate, refer to ASTM F00 for Exceptions..8 Gates shall be designed, constructed and installed such that their movement shall not be initiated by gravity when an automatic operator is disconnected..9 A pedestrian gate shall not be incorporated into a vehicular gate panel or that portion of the adjacent fence that the gate covers in the open position... A gap, measured in the horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in either the fully open position or the fully closed position, shall not exceed -/4 inches (57 mm), refer to ASTM F00 for Exception...4 Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function...5 All gates shall be designed with sufficient lateral stability to assure that the gate will enter a receiver guide, refer to ASTM F00 for panel types.. The following provisions shall apply to Class IV vehicular horizontal slide gates:.. All weight bearing exposed rollers 8 feet (.44 m), or less, above grade shall be guarded or covered... Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.. SPECIFIC APPLICATIONS. Any non-automated gate that is to be automated shall be upgraded to conform to the provisions of this specification.. This specification shall not apply to gates generally used for pedestrian access and to vehicular gates not to be automated.. Any existing automated gate, when the operator requires replacement, shall be upgraded to conform to the provisions of this specification in effect at that time.. VEHICULAR HORIZONTAL SLIDE GATES. The following provisions shall apply to Class I, Class II and Class III vehicular horizontal slide gates:.. All weight bearing exposed rollers 8 feet (.44 m), or less, above grade shall be guarded or covered... All openings located between 48 inches (. m) and 7 inches (.8 m) above grade shall be designed, guarded or screened to prevent a 4 inch (0 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that covers in the open position. 4. VEHICULAR HORIZONTAL SWING GATES 4. The following provisions shall apply to Class, Class II and Class III vehicular horizontal swing gates: 4.. Gates shall be designed, constructed and installed so as not to create an entrapment area between the gate and the supporting structure or other fixed object when the gate moves toward the fully open position, subject to the provisions in the 4... and The width of an object (such as a wall, pillar or column) covered by a swing gate when in the open position shall not exceed 4 inches (0 mm), measured from the centerline of the pivot point of the gate, refer to ASTM F00 for exception Except for the zone specified in Section 4..., the distance between a fixed object such as a wall, pillar or column, and a swing gate when in the open position shall not be less than 6 inches (406 mm), refer to ASTM F00 for exception. 4. Class IV vehicular horizontal swing gates shall be designed, constructed and installed in accordance with security related parameters specific to the application in question. 4

6 SAFETY» IMPORTANT SAFETY INFORMATION INSTALLATION To prevent SERIOUS INJURY or DEATH; one or more non-contact sensors shall be located where the risk of entrapment or obstruction exists. To prevent SERIOUS INJURY or DEATH from a moving gate: Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. Locate entrapment protection devices to protect in BOTH the open and close gate cycles. Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts. A swinging gate shall T open into public access ways. To prevent SERIOUS INJURY or DEATH from a moving gate: Install warning signs on the front and back of the gate in PLAIN VIEW. Permanently secure each warning sign in a suitable manner using fastening holes. ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. DO T use flooded lead acid battery. Flooded lead acid batteries will produce gases when discharging and recharging which can explode. DO T dispose of battery in fire. Battery may explode. Check with local codes for disposal instructions. WIRING To reduce the risk of SEVERE INJURY or DEATH: ANY maintenance to the operator or in the area near the operator MUST T be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with local electrical codes. TE: The operator should be on a separate fused line of adequate capacity. ALL electrical connections MUST be made by a qualified individual. DO T install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that you install an optional reversing edge BEFORE proceeding with the control station installation. ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled. ALL power and control wiring MUST be run in separate conduit. BEFORE installing power wiring or control stations be sure to follow ALL specifications and warnings described below. Failure to do so may result in SEVERE INJURY to persons and/or damage to operator. To AVOID damaging plug-in transformer, it MUST be enclosed in a suitable weatherproof enclosure and provided with proper weatherproof fixtures. To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging. To reduce the risk of FIRE or INJURY to persons use only LiftMaster part #K for replacement batteries. ADJUSTMENT Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing gate. Too much force on gate will interfere with proper operation of safety reversal system. NEVER increase force beyond minimum amount required to close gate. NEVER use force adjustments to compensate for a binding or sticking gate. If one control (force or travel limits) is adjusted, the other control may also need adjustment. After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object. 5

7 SAFETY» IMPORTANT SAFETY INFORMATION OPERATION AND MAINTENANCE READ AND FOLLOW ALL INSTRUCTIONS. NEVER let children operate or play with gate controls. Keep the remote control away from children. ALWAYS keep people and objects away from the gate. ONE SHOULD CROSS THE PATH OF THE MOVING GATE. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH. Use the emergency release ONLY when the gate is not moving. KEEP GATES PROPERLY MAINTAINED. Read the ownerʼs manual. Have a qualified service person make repairs to gate hardware. The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance. Disconnect ALL power before performing ANY maintenance. ALL maintenance MUST be performed by a LiftMaster professional. SAVE THESE INSTRUCTIONS. To reduce the risk of FIRE or INJURY to persons use only LiftMaster part #K for replacement batteries. To avoid SERIOUS personal INJURY or DEATH from electrocution, DISCONNECT electrical power to operator BEFORE proceeding. TROUBLESHOOTING To protect against fire and electrocution: Disconnect power and battery BEFORE installing or servicing operator. For continued protection against fire: Replace ONLY with fuse of same type and rating. 6

8 RE INTRODUCTION» OPERATOR SPECIFICATIONS + CARTON INVENTORY OPERATOR SPECIFICATIONS Operating Cycles: 00 per day Main Supply (Motor): 4 Vdc Current Consumption: A Power Consumption: 48 Watts Battery Charger Supply: 6 Vac, 9VA or 6 Vdc, 40VA 4" (5.6 cm) Maximum Gate Width: 6 feet (4.9 m) Maximum Gate Weight: 550 lbs. (49.5 kg) Protection Class: Travel Speed: Rated Operating Time: Temperature: Main Supply (Control) Dedicated Circuit: Absorbed Power: Protection Fuse Battery: NEMA R 4-8 seconds for a 90 opening 4 Minutes -0 C to + 50 C -4 F to + F 0V~/60Hz 0.75 Watts ATC 0A 4.5" (. cm) Weight:. lbs. (6 kg.) 4" (0. cm).5" (0.65 cm) 0" (5.4 cm) 6." (9. cm).475" DIA. (. cm DIA.) 7.4" (95 cm) 6" (5. cm) 5.5" (6 cm) CARTON INVENTORY Carton inventory is based on a Single Operator. For Primary (Gate ) and Secondary (Gate ) installation the carton inventory is doubled except for control box. Standard Control Box () Hardware Bag () Gate Operator Arm Motor Cable - Six Conductor, 9 feet (.7 m) Warning Sign () Battery () Plug-in Transformer () LA400-S (SECOND GATE OPERATOR ARM) Motor Cable - Six Conductor, 40 feet (. m) Junction Box - IP56 () Phillips Head Mounting Screws (4) Anchors (4) Terminal Block - Twelve Connectors () HARDWARE INVENTORY Post Bracket () Pull-to-Open Bracket () Hex Bolt 5/6"-8 X -/" (5) Square Neck Carriage Bolt /8"-6 X 6" () Hex Nut /8"-6 () Hex Nut 5/6"-8 (5) Flat Washer 5/6" (5) Flat Washer /8" (5) Lock Washer 5/6" (5) Lock Washer /8" (5) Gate Mounting Bracket () Hairpin Clip () Pin () Hex Bolt /8"-6 X -/" () Bolt -/4" () Keylock Cap () Keys () 7

9 INTRODUCTION» ADDITIONAL ITEMS NEEDED FOR INSTALLATION + TOOLS NEEDED ADDITIONAL ITEMS NEEDED FOR INSTALLATION PERMANENT FASTENERS FOR WARNING SIGN EARTH GROUND ROD (OPTIONAL) POWER WIRE: 0 VAC POWER WIRE (STRANDED COPPER WIRE) Wire Gauge 6 00 feet (0 m) Wire Gauge feet (05 m) OR 4 VAC TRANSFORMER (STRANDED COPPER WIRE) Wire Gauge feet (5 m) Wire Gauge 000 feet (05 m) TOOLS NEEDED During assembly, installation and adjustment of the operator, instructions will call for tools as illustrated below. Deep Well Sockets and Wrench /", 5/8", 7/6", 9/6" and /4" Drill Drill Bits /", /6", 5/6" and 5/" Clamps Welder (Optional) Carpenter's Level Adjustable End Wrench Tape Measure Pencil Screwdriver Hammer Phillips Head Screwdriver Wire Strippers (Optional) Wire Cutters (Optional) 8

10 INSTALLATION» OVERVIEW OF TYPICAL INSTALLATION LEFT-HAND GATE Warning Sign Control Box with Batteries Antenna Hinge Post Bracket Gate Bracket Operator PVC Conduit (not provided) to protect the low voltage wire from lawn mowers and string trimmers. Operator Cable Earth Ground Installation (Optional) 8 feet (.4 m) Gauge Wire Photoelectric Sensors TE: One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists at either the opening or closing direction. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving. RIGHT-HAND GATE Warning Sign Moving Gate Can Cause Injury or Death Pedestrians must use separate entrance This entrance is for vehicles only play in the gate area. gate or the operate children let not Do warning. prior without time any at move may Gate CLEAR! KEEP Hinge Gate Bracket Post Bracket Antenna Operator Control Box with Batteries Operator Cable Photoelectric Sensors Gauge Wire PVC Conduit (not provided) to protect the low voltage wire from lawn mowers and string trimmers. 8 feet (.4 m) Earth Ground Installation (Optional) 9

11 INSTALLATION» OVERVIEW OF TYPICAL INSTALLATION DUAL GATE Junction Box Extension Cable Hinge Warning Sign Gate Photoelectric Sensors Antenna Post Bracket Gate Bracket Gate Control Box with Batteries Operator Cable PVC Conduit (not provided) to protect the low voltage wire from lawn mowers and string trimmers. Photoelectric Sensors Gauge Wire 8 feet (.4 m) Earth Ground Installation (Optional) TE: One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists at either the opening or closing direction. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving. 0

12 INSTALLATION» CHECK YOUR GATE + MOUNTING OPTIONS CHECK YOUR GATE A B C D Gate MUST be level. Gate and gate post MUST be plumb. Remove ANY/ALL wheels from the bottom of gate. Gate MUST T hit or drag across ground. Gate MUST swing freely and be supported entirely by its hinges. A C B D MOUNTING OPTIONS Mounting locations vary depending on type and style of your gate. Minimum distance from the ground should not be less than 4 inches (0. cm) from the bottom of the gate operator arm. RECOMMENDED: = Gate post bracket mounting locations = Gate bracket mount locations OPTIONAL: = Gate post bracket mounting locations = Gate bracket mount locations

13 INSTALLATION» MANUAL RELEASE + DETERMINE POSITION OF THE PULL-TO- BRACKET + DETERMINE POSITION OF THE "OPTIONAL" PUSH-TO- BRACKET MANUAL RELEASE Insert the key into the lock and turn it 80 counterclockwise. Turn the release lever 80 counterclockwise. The operator is now in manual mode. Key Release Lever DETERMINE POSITION OF THE PULL-TO- BRACKET The Pull-to-Open bracket can be assembled to work on a Left-Hand or a Right-Hand gate. Review the gate types and select the type of installation you will require. TE: If the Pull-to-Open bracket is not assembled correctly you will damage the operator. LEFT-HAND GATE RIGHT-HAND GATE OR DETERMINE POSITION OF THE "OPTIONAL" PUSH-TO- BRACKET (T PROVIDED. SEE ACCESSORIES) LEFT-HAND GATE The Push-to-Open bracket can be assembled to work on a Left-Hand or a Right-Hand gate. Review the gate types and select the type of installation you will require. RIGHT-HAND GATE

14 INSTALLATION» ASSEMBLE GATE POST BRACKET (PULL-TO-) + ATTACH BRACKETS TO GATE OPERATOR All the illustrations on the following pages display a typical Left-Hand Gate installation. For Push-to-Open installations refer to instructions with Push-to-Open kit ASSEMBLE GATE POST BRACKET (PULL-TO-) Assemble gate post bracket by placing Pull-to-Open bracket on top of post bracket. Insert the bolt through both brackets and secure with washer, lock washer and nut. Hex Bolt /8" /8" Extension Pull-to-Open Bracket Bracket Post Bracket Bracket Washer Lock Washer Washer Nut ATTACH BRACKETS TO GATE OPERATOR Attach post bracket assembly to operator using pins and hairpin clips. Pin Attach gate bracket to operator using pins and hairpin clips. Pin Post Bracket Assembly Hairpin Clip Gate Bracket Hairpin Clip

15 INSTALLATION» DETERMINE MOUNTING LOCATION + MEASURING AND MARKING FOR THE GATE BRACKET DETERMINE MOUNTING LOCATION The gate post bracket assembly can be mounted several places on the gate post. Refer to the illustrations on page for the ideal mounting location. Refer to the illustrations to determine the appropriate dimensions for the Pull-to-Open bracket. TE: It may be necessary to add shims (angle iron, sheets of metal or wood) to the gate post to achieve the required dimensions. Gate Post Gate Hinge Point Operator Hinge Point 7" (8 cm) 7" (8 cm) Gate Post Operator Hinge Point Gate Hinge Point 7" (8 cm) 7" (8 cm) Gate Post Gate Hinge Point Operator Hinge Point 7" (8 cm) 7" (8 cm) Gate Post Gate Hinge Point Gate Post Gate Hinge Point Gate Post Gate Hinge Point Operator Hinge Point 7" (8 cm) 7" (8 cm) Operator Hinge Point 7" (8 cm) 7" (8 cm) Operator Hinge Point 7" (8 cm) 7" (8 cm) MEASURING AND MARKING FOR THE GATE BRACKET Before proceeding, begin with the gate in the fully closed position. There are two methods for determining the proper location of the post brackets: Paper template (Located on the back page of this manual. Must be cut out.) Tape measure. Either method will work depending on preference. TEMPLATE METHOD Close the gate. Place the template (provided on the back page of this manual) under the center of the gate hinge point. Use a screwdriver or dowel rod to temporarily mark the location in front of the gate post. TOP VIEW Gate Post Gate Hinge Point Gate TAPE MEASURE METHOD 4 5 Close the gate. Place the measuring tape under the center of the gate hinge point and measure out 7 inches (8 cm). Use a screwdriver or dowel rod to temporarily mark the location of the first measurement. Measure 7 inches (8 cm) from the previous mark. Use the screwdriver or dowel rod to mark the location of the second measurement. 5 TOP VIEW Gate Post Gate Hinge Point Gate 4 7" (8 cm) 7" (8 cm) 4

16 INSTALLATION» POSITION GATE OPERATOR ON GATE POSITION GATE OPERATOR ON GATE TE: The post bracket assembly can be mounted several places on the gate post. Refer to page for mounting options. Mark Open the gate to desired open position (no greater than 00 ) and hold operator against gate. Place the operator arm against gate post at the desired position. Temporarily secure gate post bracket with clamp. The gate operator (arm) must be level. mounting holes on gate for reference. Temporarily secure the gate bracket using a clamp. 4 5 Align the Pull-to-Open bracket to a position as AS POSSIBLE above the screwdriver or dowel rod. Insert hex bolt through Pull-to-Open bracket and post bracket and secure with washer, lock washer and nut. 4 7" (8 cm) 7" (8 cm) Hex Bolt /8" 5 Washer Lock Washer Nut 5

17 INSTALLATION» TEST GATE TRAVEL + SECURE POST BRACKET TO GATE POST TEST GATE TRAVEL TE: If gate does not open and close completely adjust the position of the gate bracket and mark new mounting holes. Manually open and close the gate. Ensure that the operator does not bind against the Pull-to-Open bracket. Ensure that the piston does not bottom out. /" (. cm) Do not allow piston to fully extend or fully retract. /" (. cm) SECURE POST BRACKET TO GATE POST The gate operator (arm) must be level. Mark holes for the post bracket. Remove the clamp and the operator, set aside. Drill adequate holes in the gate post. Secure the post bracket to the gate post using hardware. Hex Nuts Flat Washers Lock Washers Carriage Bolts Welder (Optional) 6

18 INSTALLATION» SECURE GATE BRACKET TO GATE + WARNING SIGN PLACEMENT SECURE GATE BRACKET TO GATE The gate operator (arm) must be level. Some installations may require additional reinforcement be installed on the gate. Reinforcement Area OR Angle Iron Wood Drill holes in gate (or reinforcement, if necessary) that are large enough for the gate bracket mounting hardware. Secure the gate operator to the gate using hardware (not provided). Manually move the gate to verify that it opens and closes fully. Operator OR Flat Bar Welder (Optional) Hex Nut Lock Washer Flat Washer Gate Bracket Hex Bolt WARNING SIGN PLACEMENT Warning signs MUST be installed on both sides of the gate and in plain view. Fasten warning signs to the gate with cable ties. Fence Gate Post Gate Gate Travel Path Moving Gate Can Cause Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only Pedestrians must use separate entrance Inside Property If installing a nd operator, repeat the previous installation steps for the second gate before proceeding to the next page. 7

19 INSTALLATION» STANDARD CONTROL BOX MOUNT THE CONTROL BOX The control box MUST be mounted within 5 feet (.5 m) of the gate operator. Mount the control box as high as possible for best radio reception Remove screws and open the control box. Disconnect the reset button, alarm, and coaxial connector. Loosen screws to remove the control board and mounting bracket. Remove the control board. Remove batteries and set aside. Select mounting holes and knock out using a screwdriver and hammer. Secure the control box to mounting surface using the appropriate hardware (not provided). A. Post B. Wall C. Column 5 Alarm 4 Coaxial Connector Reset Button Connections 6 Knock Outs Knock Outs Knock Outs Knock Outs 7 A. B. C. 8

20 INSTALLATION» STANDARD CONTROL BOX INSTALL THE CONTROL BOARD TE: Make sure the battery leads are on the left side of the control box and not pinched. Attach the antenna. Reinstall the batteries, control board, alarm and reset button. Coaxial Connector Reset Button Connections Alarm 9

21 ALARM LOCK GATE SOL GND MAGR BR GR WH YL BL RD ACCESSORY POWER V BR GR WH YL BL RD GATE LEARN XMITTER ON LOCK / BIPART DELAY GATE LEARN S GATE SINGLE BUTTON ON TIMER TO FORCE AUTO LOW BATT MAX MAX EDGE EDGE/ CONTROL INPUTS SINGLE BUTTON RE STOP CTRL PWR CTRL PWR LOOP INPUTS SHADOW INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR ALARM SOL GND MAGR LOCK GATE BR GR WH YL BL RD ACCESSORY POWER V BR GR WH YL BL RD GATE ON LEARN LOCK / XMITTER BIPART DELAY GATE LEARN S GATE ON TIMER TO FORCE AUTO LOW BATT MAX MAX SINGLE BUTTON SINGLE BUTTON RE STOP CTRL PWR CTRL PWR SHADOW INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR EDGE EDGE/ CONTROL INPUTS LOOP INPUTS INSTALLATION» LARGE METAL CONTROL BOX (XLM) MOUNT THE CONTROL BOX (XLM) The control box MUST be mounted within 5 feet (.5 m) of the gate operator. Mount the control box as high as possible for best radio reception. 90 Open the control box. The control box door may be removed by opening the door 90. Lift the door from the hinges and set aside until the installation is complete. The control box can be mounted to a post with 'U' bolts. See chart below. The knock out will accommodate a /8" diameter 'U' bolt. Type and Size 'U' Bolt Opening Standard " Round Pipe -/" Standard 4" Square Post 4" Standard 6" Square Post 6" Select center mounting holes (top and bottom) knock out using a screwdriver and hammer. Use knock outs located at the 4 corners of the control box for wall or column mounting. EARTH GROUND ROD INSTALLATION (REQUIRED) It is important to install the ground rod when using a metal control box to prevent serious injury to persons or damage to the operator. Install earth ground rod within feet (0.9 m) of the operator. Connect ground rod with # copper wire to one of the two green ground screws inside the control box. Ground Screw Standoffs TE: The additional standoffs are specifically designed to mount up to Chamberlain loop detectors model LO7LP (not provided). 0

22 ALARM SOL GND MAGR LOCK GATE BR GR WH YL BL RD ACCESSORY POWER V BR GR WH YL BL RD GATE ON LEARN LOCK / XMITTER BIPART DELAY GATE LEARN S GATE ON TIMER TO FORCE AUTO LOW BATT MAX SINGLE BUTTON SINGLE BUTTON RE MAX STOP CTRL PWR CTRL PWR EDGE EDGE/ CONTROL INPUTS LOOP INPUTS SHADOW INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR INSTALLATION» LARGE METAL CONTROL BOX (XLM) WIRING Select the knock out in the bottom of the control box based on the application requirements. Depending on the voltage and application the 0 Vac access panel may be removed to access the wiring. Connect two 7AH batteries, purchased separately. See Accessories page. IMPORTANT TE: There are two receptacles located inside the control box. One of the receptacles is for the control board power supply. The second receptacle can be used to power up additional gate operator accessories. 0 Vac ONLY The XLM control box wires the same as the standard control box. Follow all instructions for the standard control box. The illustrations show the standard control box, not the XLM control box.

23 U4 MAX C C4 F6 F FUSE GATE BRN GRN WHT YEL BLU RED WIRING» CONNECT THE GATE OPERATOR (GATE ) TO THE CONTROL BOX CONNECT THE GATE OPERATOR (GATE ) TO THE CONTROL BOX 4 5 Select hole in bottom of the control box to be used for the operator cable. Insert the watertight connector into the bottom of the control box and tighten with nut. Insert the operator cable through the watertight connector mounted in the bottom of the control box. Extend the operator cable and wires to the Gate connector and connect as shown. Tighten watertight connector nut. 4 GATE NC Z 0A V BRN GRN WHT YEL DØ BLU RED Nut ACCESSORY POWER Z 5 Watertight Connector Operator Cable Watertight Connector Nut Terminal blocks can be removed to simplify wiring. Moving Gate Can Cause Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only Pedestrians must use separate entrance Operator Cable If installing one operator, proceed to page 7. If installing two operators, continue to the next page.

24 BIPART DELAY Z9 Z8 WIRING» THE BIPART DELAY (MODEL LA400-S ONLY) THE BIPART DELAY (MODEL LA400-S ONLY) In some dual gate installations, one gate will need to open first and close second. This would happen if there was an ornamental overhang on one gate or if using a solenoid lock, for example. This gate is called the Primary gate and needs to be connected to Gate connections on the control board. Thus, it is preferred that the control box be installed on the same side as this gate. If there is no appropriate location on that side for the control box, then mount the control box on the opposite side, but connect the operator closest to the control box to the Gate connector and the operator on the opposite side to the Gate connector. TE: The gate with the longer travel span (opening) must be set as the primary gate (GATE ). Set the Bipart Delay to desired setting. The range is 0 to 8 seconds, 0 seconds is. BI-PART DELAY The following illustration shows a dual gate configuration with a decorative overlapping piece on the outside of the gate. If a solenoid lock is being used on a gate, the gate with the lock attached to it is the primary gate. OUTSIDE PROPERTY MAX Primary Gate - Connect to Gate Connector on Control Board. Primary Gate OUTSIDE PROPERTY

25 P U4 MAX C C4 F6 F GATE GATE BRN GRN WHT YEL BLU RED BRN GRN WHT YEL BLU RED WIRING» CONNECT THE GATE OPERATOR (GATE ) TO THE CONTROL BOX (MODEL LA400-S ONLY) CONNECT THE GATE OPERATOR (GATE ) TO THE CONTROL BOX (MODEL LA400-S ONLY) Before digging, contact local underground utility locating companies. Trench across driveway to bury the extension cable. Use PVC conduit to prevent damage to cables. 4 Select hole in bottom of the control box to be used for the extension cable. Insert extension cable through watertight connector nut and through an available watertight connector mounted in the control box. Extend cable and wires to Gate connector and connect as shown. Secure extension cable to control box using watertight connector nut. Junction Box Extension Cable Gate Operator (Gate ) PVC conduit at least 8" (45.7 cm) below ground level (grade) Moving Gate Can Cause Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only Pedestrians must use separate entrance Gate Operator (Gate ) Control Box ACCESSORY POWER R9Ø 4V BRN Terminal blocks can be removed to simplify wiring. GATE R4 C GRN WHT YEL BLU RED D5 4 VAC/ SOLAR INPUT R96 0A V 4 Operator Cable Extension Cable PVC Conduit 4

26 WIRING» JUNCTION BOX (MODEL LA400-S ONLY) JUNCTION BOX The following items are required to complete the junction box installation: 4 x 4 Junction Box with /4" NPT threaded port holes Screws PVC Conduit Open the junction box by removing screws (4) and set aside. Screws (4) Junction Box Cover Junction Box 4 Select holes to be used for mounting and knock out using a screwdriver and hammer. Drill two holes in the bottom of the junction box large enough for the watertight connectors. Mount the junction box within 5 feet (.5 m) of second operator. Route operator cable and extension cable through watertight connector nut and watertight connector. Knock Out Knock Out Knock Out 5 Insert cables and watertight connectors into the holes in the bottom of the junction box (not provided). Junction Box 6 Secure with connector nut. Within 5 (.5 m) Junction Box Extension Cable Gate Operator (Gate ) Connector Nut Nut 6 Connector Nut Nut Extension Extension Cable Cable 5 Watertight Wiretight Connector Connector Watertight Wiretight Connector Connector Operator Operator Cable Cable 4 5

27 WIRING» JUNCTION BOX (MODEL LA400-S ONLY) 7 Insert wires from extension cable and operator cable into terminal block connector. 7 Special Terminal Block Connector Brown Brown Green Brown Brown Green Operator Cable White White Extension Cable Yellow Yellow Blue Blue Blue Red Red Put wires inside of junction box. Secure operator and extension cables with watertight connector nut. Reinstall cover. Extension Cable Terminal Block 8 Operator Cable Watertight Connector Nut 9 Watertight Connector Nut 0 Screws (4) Screws (4) 6

28 Off Off Off Off WIRING» CONNECT TRANSFORMER TO CONTROL BOARD CONNECT TRANSFORMER TO CONTROL BOARD TE: All power wiring should be on a dedicated circuit, calculated using NEC guidelines. Local codes and conditions must be reviewed for suitability of wire installation. EXTERNAL RECEPTACLE The transformer can be plugged into a receptacle external to the control box. Run low voltage wire between the transformer and control box. TE: The transformer must be located in a dry location that is protected from weather conditions, such as inside the house or garage. This will create more space in the standard control box for accessories. Control Box Moving Gate Can Cause Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only Pedestrians must use separate entrance Operator Dedicated Outlet Transformer OR INTERNAL RECEPTACLE Connect 0 Vac directly to the control box and plug the transformer into the receptacle inside the control box. Control Box Transformer Circuit Panel Refer. Bus,, Conference Rm, Conference Room Conference Room On On On On On Off Off Off Air () Conditioner Main Room LA400 Bathroon. Comp. Serve Eug. Dept. Air () Conditioner Manu. Rm Comp. Serve Off Main Dept. Manu. Rm 7

29 ALARM MAGLOCK GATE Z ACCESSORY POWER GATE J4 R4 C FUSE FUSE C POWER D5 MOV C64 BATT BATT U WIRING» EARTH GROUND ROD INSTALLATION (OPTIONAL) + CONNECT BATTERIES EARTH GROUND ROD INSTALLATION (OPTIONAL) TE: For proper operation, do not connect the earth ground rod to the green screw on the outlet plate. Install earth ground rod within feet (0.9 m) of the operator. Disconnect and remove the green/yellow ground wire connected to the screw terminal of the control board. J4 R4 C 4 VAC/ SOLAR INPUT Attach earth ground rod wire to the screw terminal of the control board marked. Ensure the power wiring ground connection remains securely connected to the green screw on the outlet plate. Control Box Ground Screw ' (0.9 m) Gauge Wire 8' (.4 m) Earth Ground Installation (Optional) CONNECT BATTERIES The batteries are the main source of power for the operator. The operator is a battery run system. Both batteries are charged in circuit using the transformer (provided). The 4 Vac input can accept a charging transformer (6 Vac, 9 VA or 6 Vdc, 40 VA). Connect the plugs from the batteries to the connectors on the control board. J4 4 VAC/ INPUT MOV USE DEDICATED CIRCUIT BATT BATT Connector BATT Connector 8

30 ON ON SINGLE DUAL NC NC S O N 4 5 SAVE MAGLOCK MODE EDGE O N ADJUSTMENT» DIP SWITCH DIP SWITCH The Save switch must be in the position prior to adjusting the switches. After the adjustments are made the Save switch must be in the ON position in order for the changes to be saved. Set the Save switch to the position. Set switch to Single for single gate installation. For Dual (Gate and ) installation set switch on Dual Mode. F F SINGLE S 4 5 ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE Set the Save switch to the ON position. SINGLE SINGLE O 4 5 O 4 5 N N ON ON DUAL MODE NC NC ON ON DUAL MODE NC NC GATE GATE AND GATE SINGLE O 4 5 N ON SAVE ON DUAL MODE NC NC 9

31 D4 D U4 R K D9 Z Z4 U D6 D4 D D R R F K ADJUSTMENT» S S The limits are internal settings that indicate when the gates are in the fully open position and the fully closed position. For proper functionality, the limits must be programmed during the installation process. The programming uses a combination of buttons on the control board. The specific buttons used for programming depends on which side of the gate the control box is mounted and how many operators the installation includes. Refer to pages and to determine if the gate is Left-handed or Right-handed. If a mistake is made during programming press the RE button on the outside of the control box to start over. The programming times-out automatically after 60 seconds of inactivity. Close the gate. Engage the operator by turning the release lever clockwise 80, then turning the key clockwise 80. SINGLE ARM LEFT-HAND SIDE PROGRAM Press the LEARN S button ( LED will blink). LEARN S button OR PROGRAM SINGLE ARM RIGHT-HAND SIDE Press the LEARN S button ( LED will blink). LEARN S button 4 Press the Gate right button to move gate to the desired position. RE BUTTON DIAGSTIC GATE 4 Press the Gate left button to move gate to the desired position. DIAGSTIC RE BUTTON GATE 5 When gate is in the desired position, press the LEARN S button again. Control board will beep. 5 When gate is in the desired position, press the LEARN S button again. Control board will beep. PROGRAM Press the Gate 6 left button to move gate to the desired D position. DIAGSTIC GATE PROGRAM When the LED blinks, press the Gate right button. 6 DIAGSTIC GATE 7 When gate is in the desired closed position, press the LEARN S button again. 7 When gate is in the desired closed position, press the LEARN S button. The control board beeps and the and LEDs stop blinking, programming is now complete. (If the LED continues to blink, repeat programming. If the problem continues, see Troubleshooting section.) Test the limits by pressing the SBC to open and close the gate. 0

32 D4 D U4 R K ADJUSTMENT» S S TES: The gate with the longer travel span (opening) must be set as the primary gate (GATE ). If one gate is overlapping the other, the gate that is overlapping must be connected to GATE so it will start moving before the other gate; GATE may need to be closed first if there is overlap or a gate lock is being used. The programming can be exited at any time by pressing the RE button. Programming times-out automatically after 60 seconds of inactivity. DUAL GATE (LEFT-SIDE PRIMARY OPERATOR) Close the gate. Engage the operator by turning the release lever clockwise 80, then turning the key clockwise 80. PROGRAM Press the LEARN S button ( LED will blink). LEARN S button RE BUTTON 4 Press the GATE right button to open the left operator. DIAGSTIC GATE 5 6 Press the GATE right button to move the right operator into the position. FORCE LE S GATE Press the LEARN S button. Control board will beep. PROGRAM When the S LED blinks, press the GATE left button to close the right operator. FORCE LE GATE Press the GATE left button to close the left operator. DIAGSTIC GATE Press the LEARN S button. The control board beeps and the and LEDs stop blinking, programming is now complete. (If the LED continues to blink, repeat programming. If the problem continues, see Troubleshooting section.) Test the limits by pressing the SBC to open and close the gate.

33 D4 D U4 K ADJUSTMENT» S S TES: The gate with the longer travel span (opening) must be set as the primary gate (GATE ). If one gate is overlapping the other, the gate that is overlapping must be connected to GATE so it will start moving before the other gate; GATE may need to be closed first if there is overlap or a gate lock is being used. The programming can be exited at any time by pressing the RE button. Programming times-out automatically after 60 seconds of inactivity. DUAL GATE (RIGHT-SIDE PRIMARY OPERATOR) Close the gate. Engage the operator by turning the release lever clockwise 80, then turning the key clockwise 80. PROGRAM LEARN S button Press the LEARN S button R ( LED will blink). RE BUTTON Press the GATE left button to open the right operator. DIAGSTIC GATE Press the GATE left button to move the left operator into the position. FORCE LE S GATE Press the LEARN S button. Control board will beep. PROGRAM When the S LED blinks, press the GATE right button to close the left operator. FORCE LE GATE Press the GATE right button to close the right operator. DIAGSTIC GATE Press the LEARN S button. The control board beeps and the and LEDs stop blinking, programming is now complete. (If the LED continues to blink, repeat programming. If the problem continues, see Troubleshooting section.) Test the limits by pressing the SBC to open and close the gate.

34 D4 D D4 D FORCE TIMER TO ADJUSTMENT» FORCE ADJUSTMENT + TIMER-TO- (TTC) Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing gate. Too much force on gate will interfere with proper operation of safety reversal system. NEVER increase force beyond minimum amount required to close gate. NEVER use force adjustments to compensate for a binding or sticking gate. If one control (force or travel limits) is adjusted, the other control may also need adjustment. After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object. FORCE ADJUSTMENT The operator is equipped a with an obstruction current sensing feature. If the gate encounters an obstruction the operator will automatically reverse direction and stop. Based on the length and weight of the gate it may be necessary to make force adjustments. The force adjustment should be high enough that small objects such as branches or wind will not cause nuisance interruptions but low enough to prevent serious injury to a person or a vehicle. TO ADJUST THE FORCE Using the -button remote or the Single Button Control (SBC) button on the control board, open and then close the gate. 4 If the gate stops or reverses before reaching the fully open or closed position increase the force by turning the force control slightly. FORCE MAX Run operator through a complete cycle. Test the force by making sure the gate will stop and reverse on contact with an obstruction. TE: Weather conditions can affect the gate movement, so seasonal adjustment may be required. The force control is factory set to the mid position. TIMER-TO- (TTC) The Timer-to-Close feature can be set to automatically close the gate after a specified time period. The TTC is factory set to. If the TTC is set to the position, then the gate will remain open until the operator receives another command from a remote control or SBC. The gate must be fully open for the timer feature to activate and close the gate. TO THE TIMER-TO- Rotate the Timer-to-Close dial to the desired setting. The range is 0 to 80 seconds, 0 seconds is. The "TIMER RUNNING LED" will flash once for every second of adjusted time. TE: Any radio command, SBC or command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from the loops, close edges and close photoelectric sensors (IR s). TIMER TO MAX

LA412 & LA412-S O W N E R ' S M A N U A L 12 VOLT DC SINGLE SOLAR RESIDENTIAL GATE OPERATOR FOR RESIDENTIAL USE ONLY 2 YEAR WARRANTY

LA412 & LA412-S O W N E R ' S M A N U A L 12 VOLT DC SINGLE SOLAR RESIDENTIAL GATE OPERATOR FOR RESIDENTIAL USE ONLY 2 YEAR WARRANTY LA & LA-S VOLT DC SINGLE SOLAR RESIDENTIAL GATE OPERATOR O W N E R ' S M A N U A L FOR RESIDENTIAL USE ONLY Please read this manual and the enclosed safety materials carefully! Periodic checks of the operator

More information

INSTALLATION MANUAL MODEL LA412 RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant. LA4121PKGDC Single Arm Package

INSTALLATION MANUAL MODEL LA412 RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant. LA4121PKGDC Single Arm Package RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR MODEL LA412 LA4121PKGDC Single Arm Package LA412DC Primary 12 VDC Actuator Arm for single swing gate applications LA412DCS Secondary 12 VDC Actuator Arm

More information

COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL

COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL Model HCTDCU HCTDCU Motor Unit HCT08 8 Foot Rail HCT10 10 Foot Rail HCT12 12 Foot Rail THIS PRODUCT

More information

INSTALLATION MANUAL MODEL LA500 LIGHT COMMERCIAL - RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant

INSTALLATION MANUAL MODEL LA500 LIGHT COMMERCIAL - RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant LIGHT COMMERCIAL - RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR MODEL LA500 LA5001PKGDC Single Arm Package LA500DC Primary 24 VDC Actuator Arm for single swing gate applications LA500DCS Secondary 24 VDC

More information

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 OPERATION 31 INTRODUCTION 5 ACCESSORY WIRING 34 INSTALLATION 9 MAINTENANCE 36

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 OPERATION 31 INTRODUCTION 5 ACCESSORY WIRING 34 INSTALLATION 9 MAINTENANCE 36 TABLE OF CONTENTS SAFETY 1 SAFETY SYMBOL AND SIGNAL WORD REVIEW...1 USAGE CLASS...2 UL325 ENTRAPMENT PROTECTION REQUIREMENTS...2 SAFETY INSTALLATION INFORMATION...3 GATE CONSTRUCTION INFORMATION...4 INTRODUCTION

More information

Eagle Access Control Systems, Inc. / (800) / (3)

Eagle Access Control Systems, Inc. / (800) /  (3) UL Listings IMPORTANT SAFETY INSTRUCTIONS A. WARNING To reduce the risk of injury or death: 1) READ AND FOLLOW ALL INSTRUCTIONS. 2) Never let children operate or play with gate controls. Keep the remote

More information

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 ACCESSORY WIRING 29 INTRODUCTION 5 EXPANSION BOARD 31 INSTALLATION 9

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 ACCESSORY WIRING 29 INTRODUCTION 5 EXPANSION BOARD 31 INSTALLATION 9 TABLE OF CONTENTS SAFETY 1 SAFETY SYMBOL AND SIGNAL WORD REVIEW...1 USAGE CLASS...2 UL325 ENTRAPMENT PROTECTION REQUIREMENTS...2 SAFETY INSTALLATION INFORMATION...3 GATE CONSTRUCTION INFORMATION...4 INTRODUCTION

More information

LA500 & LA500-S VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL

LA500 & LA500-S VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL LA00 & LA00-S VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL Your model may look different than the model illustrated in this manual. THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS

More information

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL Model RSW12U THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. This model is for use on vehicular

More information

INSTALLATION M ANUAL

INSTALLATION M ANUAL INSTALLATION MANUAL Table of Contents UL Listings Installing the Warning Sign / Precautions Methods of Installation / Compact Installation Mounting the Secondary Entrapment / Welding Gate Arn Mounting

More information

SPECIFICATIONS AND WARNINGS SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one

More information

Actuator Arm and Control Box Mounting

Actuator Arm and Control Box Mounting Actuator Arm and Control Box Mounting To wire this operator and complete the installation, refer to a specific control box Wiring/Owner s manual. 6002 Vehicular Swing Gate Operator 6002-065-Y-1-13 Copyright

More information

LA500 & LA500-S VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL

LA500 & LA500-S VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL LA00 & LA00-S VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL Your model may look different than the model illustrated in this manual. THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS

More information

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL Model RSW12UL THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. This model is for use on vehicular

More information

RESIDENTIAL DC VEHICULAR SLIDE GATE OPERATOR

RESIDENTIAL DC VEHICULAR SLIDE GATE OPERATOR RESIDENTIAL DC VEHICULAR SLIDE GATE OPERATOR INSTALLATION MANUAL Model RSL12UL THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. This model is for use on vehicular

More information

COMMERCIAL DC VEHICULAR SWING GATE OPERATOR

COMMERCIAL DC VEHICULAR SWING GATE OPERATOR COMMERCIAL DC VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL Model CSW24UL THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. This model is for use on vehicular

More information

MODEL LA100 LIGHT-DUTY RESIDENTIAL DC ACTUATOR GATE OPERATOR OWNER S MANUAL

MODEL LA100 LIGHT-DUTY RESIDENTIAL DC ACTUATOR GATE OPERATOR OWNER S MANUAL The Chamberlain Group, Inc. 300 Windsor Drive Oak Brook, IL 60523 www.liftmaster.com MODEL LA100 LIGHT-DUTY RESIDENTIAL DC ACTUATOR GATE OPERATOR OWNER S MANUAL RESIDENTIAL USE ONLY Please read this manual

More information

WARNING GATE LOCK MODEL SGLOCK12V

WARNING GATE LOCK MODEL SGLOCK12V GATE LOCK MODEL SGLOC2V The SGLOC2V Automatic is compatible with LiftMaster Gate Access Systems LA412, LA412-S, and RSW operators. The purpose of the automatic gate lock is to securely lock the gate in

More information

AUTOMATIC GATE OPENER

AUTOMATIC GATE OPENER AUTOMATIC GATE OPENER INSTALLATION MANUAL Model G750 For Single Gates AUTOMATIC GATE OPENER Installation Manual GATE OPENER CLASS CATEGORIES* The Zareba Automatic Gate Opener is intended for use with vehicular

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS 582 HP OPEN CLOSE Wiring / Owner s Manual Use this manual for circuit board 02-010 Revision A or higher. 115 VAC Control Boxes for 6002, 600, 600 and 600 gate operators 02-065-E-5-12 CFORMS TO ANSI/UL-25

More information

Vehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing

Vehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing Vehicular Swing Gate Operator Nice Gate Operators Titan 912L The Titan 912L Gate Operator is intended for use with vehicular swing gates. The Titan 912L Gate Operator can be used in Class I, Class II and

More information

Photoelectric. Sensors Invisible Light Beam Protection Area

Photoelectric. Sensors Invisible Light Beam Protection Area COMMERCIAL PROTECTOR SYSTEM MODELS CPS-U AND CPS-UN4 To prevent possible SERIOUS INJURY or DEATH from a closing gate or door: Entrapment protection devices MUST be installed per the operator owner's manual.

More information

AUTOMATIC GATE OPENER

AUTOMATIC GATE OPENER AUTOMATIC GATE OPENER Part # 7001282.001 Rev.A INSTALLATION MANUAL Model G752 For Double Gates AUTOMATIC GATE OPENER Installation Manual GATE OPENER CLASS CATEGORIES* The Zareba Automatic Gate Opener is

More information

Installation/Owner s Manual Model 9050

Installation/Owner s Manual Model 9050 8 CLASS HP MODEL VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 900 Use this manual for circuit board 70-00 Revision AA or higher. Vehicular Slide Gate

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS MODEL SERIAL 58 HP CLOSE Wiring / Owner s Manual Use this manual for circuit board 0-010 Revision A or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT function.

More information

Installation/Owner s Manual Series 6500

Installation/Owner s Manual Series 6500 Installation/Owner s Manual Series 00 Use this manual for circuit board 0-00 Revision E or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT function. Vehicular Swing

More information

Safety Installation Information Single Gate Opener Parts List...4. Dual Gate Opener Parts List...5. Technical Specifications & Features...

Safety Installation Information Single Gate Opener Parts List...4. Dual Gate Opener Parts List...5. Technical Specifications & Features... Table of Contents ` Safety Installation Information..... 2-3 Single Gate Opener Parts List.........4 Dual Gate Opener Parts List........5 Technical Specifications & Features...........6-7 Installation

More information

Owner s Manual. Model 9150 Vehicular Slide Gate Operator

Owner s Manual. Model 9150 Vehicular Slide Gate Operator Owner s Manual Model 9150 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9150-065 REV D, 5/07

More information

UGP-712 Vehicular swing gate operator

UGP-712 Vehicular swing gate operator Vehicular swing gate operator INSTALLATION INSTRUCTION MANUAL PLATINUM ACCESS SYSTEMS Installation Instructions & Safety Information Manual Vehicular Swing Gate Operator Class I, Class II, Class III, and

More information

Installation/Owner s Manual Series 6500

Installation/Owner s Manual Series 6500 Installation/Owner s Manual Series 00 Use this manual for circuit board 0-08 Revision A or higher. Vehicular Swing Gate Operator Entrapment Protection must be provided for the gate system where the risk

More information

Sliding Gate Opener User s Manual

Sliding Gate Opener User s Manual Gat Model: Sliding Gate Opener User s Manual GA2500 Gate1Access, LLC. www.gate1access.com Email: support@gate1access.com 1 Thank you for purchasing GA2500 gear rack drive sliding gate opener. We are sure

More information

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator Installation/Owner s Manual Model 652-080 AC Powered Vehicular Swing Gate Operator Use this manual for circuit board 100-010 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the

More information

Installation/Owner s Manual

Installation/Owner s Manual CLASS MODEL SERIAL HP 53382 Read owner s manual and safety instructions. Installation/Owner s Manual Use this manual for circuit board 4502-010 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST

More information

MODEL SW420 LIGHT-DUTY RESIDENTIAL SWING GATE OPERATOR

MODEL SW420 LIGHT-DUTY RESIDENTIAL SWING GATE OPERATOR The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com MODEL SW420 LIGHT-DUTY RESIDENTIAL SWING GATE OPERATOR OWNER S MANUAL Intended for professional installation

More information

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator MODEL 8 Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator Use this manual for circuit board 0-00 Revision D or higher. 9000-0-N-- WARNING MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH

More information

MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR

MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR CTROLLER BOARD GL MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR MODEL SW490 HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date INTENDED FOR PROFESSIAL

More information

MODEL SW470 MODEL SW490 MEDIUM DUTY SWING GATE OPERATOR HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD

MODEL SW470 MODEL SW490 MEDIUM DUTY SWING GATE OPERATOR HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD CTROLLER BOARD GL MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR MODEL SW490 HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date INTENDED FOR PROFESSIAL

More information

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator MODEL 8 Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator Use this manual for circuit board 0-00 Revision D or higher. 9000-0-K-7- WARNING MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH

More information

115 VAC Control Boxes for

115 VAC Control Boxes for CLASS MODEL SERIAL 8 HP DOORKING CLOSE Wiring / Owner s Manual Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator WILL NOT

More information

Installation/Owners Manual PATRIOT RSL Vehicular Slide Gate Operator Heavy Duty Battery Powered Solar or AC Charged

Installation/Owners Manual PATRIOT RSL Vehicular Slide Gate Operator Heavy Duty Battery Powered Solar or AC Charged Installation/Owners Manual PATRIOT RSL Vehicular Slide Gate Operator Heavy Duty Battery Powered Solar or AC Charged WARNING TO REDUCE THE RISK OF INJURY OR DEATH 1. READ AND FOLLOW ALL INSTRUCTIONS 2.

More information

Installation/Owner s Manual Model 9100

Installation/Owner s Manual Model 9100 CLASS MODEL VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 900 Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI

More information

Installation/Owner s Manual Series 9500

Installation/Owner s Manual Series 9500 MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Operate gate only when gate area is in sight and free of people and obstructions. Do not allow children to play in gate area or operate gate. Do not stand

More information

Installation/Owner s Manual Series 9150

Installation/Owner s Manual Series 9150 Read owner s manual and safety instructions. CLASS HP MODEL VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Series 90 Use this manual for circuit board 0-00

More information

Automatic Vehicular Gate Operating Systems: Guidelines for Specifiers, Designers, Dealers, Installers and End Users

Automatic Vehicular Gate Operating Systems: Guidelines for Specifiers, Designers, Dealers, Installers and End Users #352 Automatic Vehicular Gate Operating Systems: Guidelines for Specifiers, Designers, Dealers, Installers and End Users Overview Automatic vehicular gate operating systems provide convenience and security

More information

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS PowerMaster TABLE OF CONTENTS MODEL MBG MEDIUM DUTY BARRIER GATE OPERATOR Important Safety Information...... 3 System Designer Safety Instructions.......4 Installer Safety Instructions....... 5 Installation

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual Swing Gate Operator Model HL410-21 & HL410L-21 2 Contents Contents Parts & Components 3 Specifications & Capacities 4 Safety Information 6 Installer 6 End User 7 General

More information

Installation/Owner s Manual Series 9000

Installation/Owner s Manual Series 9000 HP MODEL VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Series 9000 Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI

More information

Installation/Owner s Manual Model 9100 Vehicular Slide Gate Operator

Installation/Owner s Manual Model 9100 Vehicular Slide Gate Operator CLASS MODEL 8 DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 900 Vehicular Slide Gate Operator Use this manual for circuit board 60-00 Revision A or higher. 900-06-Z-- WARNING MOVING GATE

More information

AC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard

AC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard Installation/Owner s Manual Model 6524-380 AC Powered Vehicular Swing Gate Operator Use this manual for circuit board 4100-018 Revision A or higher. Entrapment Protection must be provided for the gate

More information

MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR

MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR OWNER'S MANUAL Model SL930 is for vehicular passage

More information

Installation/Owner s Manual

Installation/Owner s Manual CLASS MODEL SERIAL HP 53382 DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Use this manual for circuit board 4502-010 Revision K or higher. For operators manufactured July 2011and later. Series

More information

Installation/Owner s Manual

Installation/Owner s Manual 53382 HP Read owner s manual and safety instructions. Installation/Owner s Manual Use this manual for circuit board 4502-010 Revision K or higher. For operators manufactured July 2011and later. Series

More information

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS Ramset_Man300.qxd 4/18/05 1:06 PM Page 1 FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS Ramset_Man300.qxd 4/18/05 1:06 PM Page 2 www.ramsetinc.com Ramset_Man300.qxd 4/18/05 1:06 PM Page 3 TABLE OF CONTENTS

More information

Installation/Owner s Manual

Installation/Owner s Manual CLASS MODEL SERIAL 8 HP DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Use this manual for circuit board 0-00 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate

More information

PowerMaster Model SG

PowerMaster Model SG PowerMaster Model INSTALLATION MANUAL CAREFULLY READ THIS ENTIRE MANUAL FIRST BEFORE PROCEEDING! LEAVE THIS MANUAL WITH END USER FOR FUTURE REFERENCE AFTER INSTALLATION IS COMPLETE (LAST PAGE SHOULD BE

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model BA12 12 VOLT DC BARRIER ARM OPERATOR INSTALLATION MANUAL 0707 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications... 4 Pre-Installation Checklist... 5 Operator Installation...

More information

Actuator Arm and Control Box Mounting

Actuator Arm and Control Box Mounting Actuator Arm and Control Box Mounting To wire this operator and complete the installation, refer to a specific control box Wiring/Owner s manual. 6005 Vehicular Swing Gate Operator Entrapment Protection

More information

AC Powered. AC Powered. Installation/Owner s Manual Model AC Powered Vehicular Slide Gate Operator

AC Powered. AC Powered. Installation/Owner s Manual Model AC Powered Vehicular Slide Gate Operator gate area. 53382 HP MODEL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA Installation/Owner s Manual Model 9024-080 Use this manual for circuit board 4100-010 Revision AA or higher.

More information

PowerMaster. Installation Manual UL 325 AND UL 991 LISTED MODEL RSG TABLE OF CONTENTS

PowerMaster. Installation Manual UL 325 AND UL 991 LISTED MODEL RSG TABLE OF CONTENTS MODEL RSG RESIDENTIAL SLIDE GATE OPERATOR TABLE OF CONTENTS PowerMaster Installation Manual RESIDENTIAL SLIDE GATE OPERATOR UL 325 AND UL 991 LISTED UL R Important Safety Information.....3 UL Installation

More information

MODEL MSW Medium Duty Swing Gate Operator

MODEL MSW Medium Duty Swing Gate Operator INSTALLATION AND OWNER S MANUAL MODEL MSW Medium Duty Swing Gate Operator UL 325 and UL 991 Listed 22-1/4 16-1/2 19-1/2 16 20'' LENGTH X 14-3/4'' WIDTH 2 O.D. PIPE (BY OTHERS) Serial #: Date Installed:

More information

Owner s Manual. Series 6300 Vehicular Swing Gate Operators

Owner s Manual. Series 6300 Vehicular Swing Gate Operators Owner s Manual Series 6300 Vehicular Swing Gate Operators DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 6300-065 REV E,

More information

K001A6039. Control Board Replacement Kit WARNING INSTALLATION INSTRUCTIONS APPLICATION REQUIREMENTS: FUNCTION: REMOVE EXISTING BOARD

K001A6039. Control Board Replacement Kit WARNING INSTALLATION INSTRUCTIONS APPLICATION REQUIREMENTS: FUNCTION: REMOVE EXISTING BOARD ontrol Board Replacement Kit APPLIATI REQUIREMENTS: This modification is available to all LA400 North American gate operators. FUTI: Allows existing LA400 control board in the field to be replaced or upgraded

More information

Installation/Owner s Manual 6400 Vehicular Swing Gate Operator

Installation/Owner s Manual 6400 Vehicular Swing Gate Operator 53382 HP Installation/Owner s Manual 600 Vehicular Swing Gate Operator Use this manual for circuit board 302-010 Revision A or higher. 600-065-L-7-10 Standard Control Box WARNING Deluxe Control Box CERTIFIED

More information

Owner s Manual. Model 9100 Vehicular Slide Gate Operator

Owner s Manual. Model 9100 Vehicular Slide Gate Operator Owner s Manual Model 9100 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9100-065 REV C, 1/04

More information

Owner s Manual. Overhead Gate Operator. Copyright 2015 DoorKing, Inc. All rights reserved. REV SENSE OPEN GATE FORCED NO NC

Owner s Manual. Overhead Gate Operator. Copyright 2015 DoorKing, Inc. All rights reserved. REV SENSE OPEN GATE FORCED NO NC Owner s Manual 50 Overhead Gate Operator EXIT PART REVERSE TIME DELAY REV SENSE OPEN REV SENSE CLOSE 2 3 4 5 6 7 8 2 3 4 PUSH TO OPERATE technician use only GATE FORCED NO NC Copyright 205 DoorKing, Inc.

More information

Solar Control Box for

Solar Control Box for CLASS MODEL SERIAL 53382 HP CLOSE Wiring / Owner s Manual Use this manual for circuit board 4302-010 Revision N or higher. Solar Control Box for 6002, 6003, 6004 and 6400 gate operators 4302-067-N-2-13

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk

More information

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL 10-04-00 CONTENTS Safety Precautions... 2 Applications... 3 Pre-Installation Checklist...

More information

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate Gate Operators, Inc. Model 1550 Single Swing Gate Model 1650 Dual Swing Gate Swing Gate Operator CONTENTS Safety Precautions... 2 Applications... 3 Pre-Installation Checklist... 4 Parts Identification...

More information

RAMSET

RAMSET RAMSET TABLE OF CONTENTS Important Safety Requirements & Instructions...1 Responsibilities of Installers and Technicians...2 Important Safety Requirements by UL Standards...3 Classes of Vehicular Gate

More information

Installation/Owners Manual

Installation/Owners Manual Installation/Owners Manual Ranger I Single Swing Gate Operator Ranger II Dual Swing Gate Operator Heavy Duty Battery Powered Solar or AC Charged WARNING TO REDUCE THE RISK OF INJURY OR DEATH 1. READ AND

More information

Owner s Manual. Series 6050 and Vehicular Swing Gate Operator. Copyright 2010 DoorKing, Inc. All rights reserved. WARNING

Owner s Manual. Series 6050 and Vehicular Swing Gate Operator. Copyright 2010 DoorKing, Inc. All rights reserved. WARNING CERTIFIED TO CAN/CSA C22.2 NO. 247 53382 VEHICULAR GATE OPERATOR CLASS HP MODEL SERIAL AMPS 60 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Operate gate

More information

Instruction Manual. Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators. No Rev

Instruction Manual. Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators. No Rev Rev 060202 Instruction Manual Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators C No. 545327 US TABLE OF CONTENTS Important Safety Requirements & Instructions.......................................1,2

More information

ontrol Systems, Inc. Swing Gate Installation Manual Eagle-200 Series Eagle-100 Series UL325 and UL991 Compliant

ontrol Systems, Inc. Swing Gate Installation Manual Eagle-200 Series Eagle-100 Series UL325 and UL991 Compliant Swing Gate Installation Manual Eagle-200 Series Eagle-100 Series ontrol Systems, Inc. www.eagleoperators.com Operator installation and instructions for the Eagle-200 and Eagle-100 Series. UL325 and UL991

More information

Installation/Owners Manual

Installation/Owners Manual Installation/Owners Manual PATRIOT I Single Swing Gate Operator PATRIOT II Dual Swing Gate Operator Heavy Duty Battery Powered Solar or AC Charged WARNING TO REDUCE THE RISK OF INJURY OR DEATH 1. READ

More information

Solar Control Box for

Solar Control Box for CLASS MODEL SERIAL 5338 HP D OOR KIN G OPEN CLOSE Wiring / Owner s Manual Use this manual for circuit board 430-010 Revision AA or higher. EXTERNAL ENTRAPMENT PROTECTI MUST be installed or the gate operator

More information

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator Manufactured by NICE SpA INSTALLATION MANUAL 08/10 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications...... 4 Pre-Installation Checklist... 5

More information

Solar Powered. Solar Powered. Installation/Owner s Manual Model UL 325 Compliant. Solar Powered Vehicular Slide Gate Operator

Solar Powered. Solar Powered. Installation/Owner s Manual Model UL 325 Compliant. Solar Powered Vehicular Slide Gate Operator MODEL 582 Installation/Owner s Manual Model 9024-081 Use this manual for circuit board 4100-010 Revision D or higher. 9024-066-H-1-15 Solar Powered Solar Powered Vehicular Slide Gate Operator WARNING MOVING

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model 3500ETL/3600ETL Commercial Swing Gate Operator INSTALLATION MANUAL 01/08 CONTENTS IMPORTANT SAFETY INSTRUCTIONS. 3 Applications... 4 Pre-Installation Checklist... 5 Parts

More information

3 Year SENTRY 300 S / 300 D. Installation/Owners Manual. High Quality Low Voltage Vehicular Swing Gate Opener

3 Year SENTRY 300 S / 300 D. Installation/Owners Manual. High Quality Low Voltage Vehicular Swing Gate Opener SENTRY 300 S / 300 D High Quality Low Voltage Vehicular Swing Gate Opener Battery Powered Solar or AC Charged Installation/Owners Manual 3 Year Warranty Designed to open all types of gates in all kinds

More information

gate operator class categories and examples

gate operator class categories and examples BLSL840 Manual_Layout 1 3/14/2014 4:06 PM Page 1 BLSL840 BLSL840 Manual_Layout 1 3/14/2014 4:06 PM Page 2 BLSL840 Manual_Layout 1 3/14/2014 4:06 PM Page 3 Installation Instructions & Safety Information

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL NEMA 4X UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the

More information

Solar Powered. Solar Powered. Model Installation/Owner s Manual. Solar Powered Vehicular Swing Gate Operator

Solar Powered. Solar Powered. Model Installation/Owner s Manual. Solar Powered Vehicular Swing Gate Operator Installation/Owner s Manual Model 6524-081 Solar Powered Vehicular Swing Gate Operator Use this manual for circuit board 4100-010 Revision AA or higher. 6524-066-S-5-18 For AC Power, See 6524-065 AC Power

More information

Installation/Owner s Manual 9245

Installation/Owner s Manual 9245 CFORMS TO ANSI/UL-35 5338 VEHICULAR GATE OPERATOR CLASS HP MODEL SERIAL MAX GATE LOAD Do not stand in gate path or walk through path while gate is moving. Read owner s manual and safety instructions. CFORMS

More information

MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR

MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR CTROLLER BOARD GL MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date MODEL SL575 IS FOR VEHICULAR PASSAGE GATES LY AND IS NOT INTENDED

More information

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators Owner s Manual Models 6050 and 6100 Vehicular Swing Gate Operators DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 6050-065

More information

FSW 900 Swing Gate Operator

FSW 900 Swing Gate Operator FSW 900 Swing Gate Operator UL325 - UL991 FAAC International Inc. Headquarter & East Coast Operations 3160 Murrell Rd Rockledge, FL 32955 Tel. 800 221 8278 www.faacusa.com FAAC International Inc. West

More information

Nice Nice Swing Gate Opener. Model 1550

Nice Nice Swing Gate Opener. Model 1550 Nice Nice Swing Gate Opener Model 1550 Revision 2.0.0.0_7-2018 TABLE OF CONTENTS 1 - OVERVIEW 4 2 - SAFETY INFORMATION 6 3 - Use of Vehicle Detectors 9 4 - Gate Construction and Safety 9 5 - Maintenance

More information

RAMSET RAM

RAMSET RAM www.ramsetinc.com TABLE OF CONTENTS Important Safety Requirements & Instructions...1 Responsibilities of Installers and Technicians...2 Important Safety Requirements by UL Standards...3 Classes of Vehicular

More information

RAM TABLE OF CONTENTS

RAM TABLE OF CONTENTS TABLE OF CONTENTS Important Safety Requirements & Instructions...1 Responsibilities of Installers and Technicians...2 Important Safety Requirements by UL Standards...3 Classes of Vehicular Gate Operators...4

More information

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 1 FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 2 www.ramsetinc.com R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 3 TABLE

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL FS Series Rolling Fire Door Operators UL325-2010 Compliant Restricted Duty Operators CORPORATION IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the

More information

Phobos N BT. Phobos N L BT. installation manual version Professional installation required. tuned to you

Phobos N BT. Phobos N L BT. installation manual version Professional installation required. tuned to you Phobos N BT installation manual version 120626 Phobos N L BT tuned to you Professional installation required 2 APPLICATIONS & CAPACITIES Important. This product is intended to be installed and serviced

More information

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

Owner s Manual. Model 9300 Vehicular Slide Gate Operator Owner s Manual Model 9300 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9300-065 Rev C 6/03

More information

Installation Manual. Post Bracket Assembly. Gate Bracket. 12 Volt automotive or marine type battery in weather proof housing (not included).

Installation Manual. Post Bracket Assembly. Gate Bracket. 12 Volt automotive or marine type battery in weather proof housing (not included). Installation Manual MM360 Receiver Gate Swings Evenly and Freely Hung Firmly and Plumb Warning Sign Post Bracket Assembly Single Gate Opener 120 Volt indoor Transformer (surge protector not supplied) Gate

More information

Nice Apollo Swing Gate Opener 1712/ VDC

Nice Apollo Swing Gate Opener 1712/ VDC Nice Apollo Swing Gate Opener 1712/1812-12VDC Vehicular Gate Control Unit 1724/1824-24VDC Revision 1.0.0.0_02-2014 TABLE OF CONTENTS CAUTIONS AND NOTES 5 EXTREMELY IMPORTANT 5 ETL DEFINITIONS COMPLIANT

More information

6002 swing gate actuator - installation guide

6002 swing gate actuator - installation guide 600 swing gate actuator - installation guide 600 Residential Swing Gate Actuator Installation Guide DKS DoorKing, Inc. 0 Glasgow, Avenue Inglewood, Ca. 900 0.645.00 0.64.586 fax info@doorking.com www.doorking.com

More information

Installation Manual for the. Automatic Gate Opener System for Single Swing Gates Only

Installation Manual for the. Automatic Gate Opener System for Single Swing Gates Only Installation Manual for the 250 E-Z GATE OPENER UL325 SERIES 1-800-543-GATE (4283) www.mightymule.com Automatic Gate Opener System for Single Swing Gates Only WARNING! This equipment is similar to other

More information

MODEL SL585 MODEL SL595 HEAVY DUTY SLIDE GATE OPERATOR HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD

MODEL SL585 MODEL SL595 HEAVY DUTY SLIDE GATE OPERATOR HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD CTROLLER BOARD GL MODEL SL585 HEAVY DUTY SLIDE GATE OPERATOR YEAR WARRANTY Serial # (located on electrical box cover) Installation Date MODEL SL595 HEAVY DUTY, HARSH ENVIRMENT SLIDE GATE OPERATOR MODELS

More information

Installation Manual for the. Automatic Gate Opener System FOR DUAL SWING GATES

Installation Manual for the. Automatic Gate Opener System FOR DUAL SWING GATES Installation Manual for the AUTOMATIC GATE OPENER Automatic Gate Opener System FOR DUAL SWING GATES WARNING! READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic

More information