KWH Meter & Panel Meter & Multimeter & Temperature Controller Thermocouple & Small Thermostat & Compass

Size: px
Start display at page:

Download "KWH Meter & Panel Meter & Multimeter & Temperature Controller Thermocouple & Small Thermostat & Compass"

Transcription

1 KWH Meter & Panel Meter & Multimeter & Temperature Controller Thermocouple & Small Thermostat & Compass DIN-RAIL KWH Meter... D01 DD28 DD862 DT862 DT8 Kilo Watt-hour Meter... D02 DDS480 Single Phase Electronic Kilowatt Hour Meter... D03 DTS480 Three Phase Electronic Kilowatt Hour Meter... D03 Modular Type Panel Meter... D04 Panel Meter... D05-06 Digital Panel Meter... D07 Model FL-2 Current Divider Peripheral... D08 Model FL-21 Current Divider Peripheral... D09 MSQ Current Transformers... D10-11 MR Current Transformers... D12 RCT Current Transformers... D13 DP Current Transformers... D14- Clamp Meter... D16 Multimeter... D16-17 Temperature Controller... D18-19 Thermocouple and Thermal Resistance... D20 PTC Heater -0W HG D21 Small PTC Heater... D22 Small Thermostat KT D23 Five-uses Compass... D24-25

2 ADM DIN-RAIL KWH Meter 1. Applications ADM is a kind of electronic Din rail watt-hour meter.it completely accords with relevant technical requirements of class 1 and class 2. It can accurately and directly measure active energy consumption. It also can display total energy consumption by step type impulse register or LCD display. This watt-hour meter is according to EN ADM25SC Conform to EN Accuracy Frequency Single phase Rated impulse voltage Power consumption Temperature range Conform to EN Accuracy Frequency Three phase Rated impulse voltage Power consumption Temperature range class 1,2 50/60Hz 120V/230V Uimp 6KV-1.2/50S 1.5w/6VA per phase class 1,2 50/60Hz 230V/400V Uimp 10KV-1.2/50S 2w/10VA per phase ADM65S ADM100S ADM100SC 2. Specification TYPE ADM25S ADM25SC(LCD) ADM65S ADM100S ADM100SC (LCD) ADM100T ADM100TC (LCD) Rating (10)A 3()A 5(25)A 5(30)A (10)A 3()A 5(30)A 10(40)A (60)A (10)A 5(30)A 10(50)A (60)A 20(100)A 5(30)A 10(60)A (90)A 20(100)A 1.5(6)A CT 3(6)A CT 5(30)A 10(60)A (90)A 20(100)A 1.5(6)A CT 3(6)A CT 5(30)A 10(60)A (90)A 20(100)A Voltage AC120V/230V AC120V/230V AC230V AC120V/230V 230V 230V 230/400V 230/400V 230/400V Mounting:DIN rail EN Class Designation 1.0/ / / Single Phase 1 module Single Phase 2 module Single Phase 4 module Single Phase 4 module Three Phaes 7 module Three Phase 7 module ADM100TC D-01

3 DD862 DD28 DD862 DT862 DT8 Kilo Watt-hour Meter 1. Applications The series single phase meter is a kind of induction meter to measure the single phase current at the rated frequency of 50Hz. It is an indoor installed meter. Ambient temperature: - 10 C to 50 C, relative humidity: below 85% (25 C). DT8 and DT862 series three-phase meter is an induction meter to measure the three-phase current at the rated frequency (50Hz). It is an indoor installed meter; Ambient temperature: -10 C to 50 C, except the first grade is under the working condition of 0 to 40 C. Relative humidity: below 85% (25 C). DD Specification Item Type Accuracy R.V. Calibration (A) Manner DD862-4 (10)5(20)10(40) (60)20(80) 30(100) direct connction connection with singlephase watt-meter DD862-2 DD (6) 3(6) 2(4)(5)3(6)5(10) current transformer DD28 10(20)20(40)30(60) direct connection DD28 three phase four-wire watt meter DT862-4 DT862-2 DT8 2 3x380/220 40(80)5(20)10(40) 5(20)10(40)(60) 20(80)3(100) 1.5(6) 3(6) direct connection connection with current transformer direct connection DD862 DD862 DT862 DT862 D-02

4 DDS480 DDS480 Single Phase Electronic Kilowatt Hour Meter 1. Application DDS480 series electronic single phase watt hour meter is a high technology product adople avanced IC technology as well as SMT technology, both circuit design and componects selectior are up to various working environment to guaranty that power meter can operate steadily for a lor time. the finished meter don t neet to be adjusted so that the calibration cycle is long. it extremely reduce the labor force of the electricity board for calibrating power meters. the feature of the products are anti-thief, long life, high accuracy, high reliability, low power consumption small volume, light weight, the meter is up to the according to IEC and GB/T standard. 2. Spcification Name Type Accuracy(class) Basic current Single Phase Electronic Kilowatt Hour Meter DDS , (6)A,(10)A,5(20)A,10(40)A, 45(60)A,20(80)A,5(30)A,10(60)A, 80ms 20ms DTS480 Three Phase Electronic Kilowatt Hour Meter 1. Application DTS480 series electronic three phase watt hour meter is a high technology product adopted advanced IC technology as well as SMT technology, both circuit design and components selectior are up to various working environment to guaranty that power meter can operate stecdily for a lon time, the finished meter don t need to be adjusted so that the calibration cycle is long, it extremely reduce the labor force of the electricity board for calibrationg power meters, the feature of the products are anti-thief, long life, high accuracy, high reliability, low power consumption small volume, light weight, the meter is up to the according to IEC and GB/T standard. 2. Name and specification Name Type Accuracy (class) Rated voltage (V) Rated current (A) Connection Three phase four 3x1.5(6), 3x3(6) CT wire adive energy electronic type watthotu meter DTS x380/220 3x5(20), 3x10(40) 3x1.5(60), 3x5(30) 3x10(60) Direct D-03

5 SFC Modular Type Panel Meter MODEL SFC-45 SFC-100 NAME AC AMMETER DC AMMETER AC VOLTMETER DC VOLTMETER FREQUENCY METER POWER FACTOR METER(COS ) POWER METER(KW OR KVAR) SPECIFICATION ACCURACY FROM 10A,A, 20A,30A TO 3000A,500A FROM 0.1A,0.5A, 1A,5A,10A,25A TO 80A,100A FROM 50μA,100μA, 1mA,5mA 1A,5A,10A,25A,30A TO 100 FROM 10A,A, 20A,30A 2500A,3000A TO 8KA,10KA FROM 30V,50V, 100V TO 300V,500V,600V FROM 1KV,2KV, 5KV TO 380KV,450KV FROM 10V,20V, 30V TO 500V,600V,1000V FROM 1KV,2KV, 5KV TO 8KV,9KV,10KV VOLTAGE: 110V,220V,380V,440V FREQUENCY: 45-55Hz,45-65hZ,55-65Hz,47-53Hz VOLTAGE: 10V,220V,380V,440V CURRENT: 1A OR 5A SCALE: 0.5cap-1-0.5ind, 0.3cap-1-0.1ind, 0.7cap-1-0.2ind WITH EXT.C/T 1A OR 5A AC DIRECT CONNECTION DC DIRECT CONNECTION WITH EXT,SHUNT 50MV,60MV OR 75MV AC DIRECT CONNECTION WITH EXT.VOLTAGE TRANSFORMER DC DIRECT CONNECTION WITH EXT. RESISTOR FOR IPHASE OR 3PHASE FOR IPIW,3P3W,3P4W CLASS 1.5 CLASS 1.5 CLASS 1.5 CLASS 1.5 CLASS 1.5 CLASS 1.5 CLASS 1.5 CLASS 1.5 CLASS 1.0 CLASS VOLTAGE: 110V,220V,380V,440V CURRENT: 1A OR5A CLASS 1.5 WITH C/T OR VOLTAGE TRANSFORMER 1. Outline Drawing 2. Size Of Din Rail Type Series Meter Model Unit D SFC-45 mm 4 SFC-100 mm 10 Number of terminal Measurement of din rail D-04

6 AM72 Panel Meter AC Ammeter Model:AM-96 AM-72 AM-48 Class:1.5 Specs:0.1A 0.5A 1A 1.5A 3A 5A 7.5A 10A A 20A 25A 30A 50A 75A(use Ext.CT 5A) Note:for60/75/100A direct meter,the class is. Advantage:The scale can be easily changed without opening the front frame so that the class will not be influenced. DC Ammeter Model:AM-96 AM-72 AM-48 Class:1.5 Specs:25uA 50uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 100mA 0mA 200mA 250mA 300mA 500mA 1A 3A 5A 7.5A 10A 20A 30A 50A 75A(used with Shunt) Feature:The scale can be easily changed without opening the front frame so that the class will not be influenced. AC Voltmeter Model:AM-96 AM-72 AM-48 Class:1.5 Specs:30V 50V 75V 100V 120V 0V 250V 300V 450V 600V For KV,should be used with potential transformer secondary voltage 100V. DC Voltmeter Model:AM-96 AM-72 AM-48 Class:1.5 Specs:3V 5V 7.5V 10V V 20V 50V 75V 100V 120V 0V 200V 250V 300V 400V 450V 600V Note:Over 600V should be used with Ext.Resistor.(Rated Cuuent 5mA). MOVING COIL INSTRUMENTS FOR NONELECTRIC VALUES Model:AM-96 AM-72 These meters can measure the other non-electric values for example,temperature,speed and so on. Frequency Meter Pointer Type Model:AM-96 AM-72 AM-48 Class:1.0 Volt:50V 100V 220V 380V Freq:44-55Hz 45-66Hz 55-65Hz 47-53Hz 57-63Hz 44-56Hz 54-66Hz Hz Hz D-05

7 AM96 Panel Meter POWER FACTOR For 3 phases circuits,balanced load 45-65Hz and for 1 phase AC 50Hz. Model:AM-96 AM-72 Class: Voltage:100V 380V 440V Frequency:50Hz 60Hz Scale graduation:0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3ind. Orders to be Noted: Type of Current:1P,3P 3W circuits,balanced load. Rated Volt:The voltage is line voltage(between two wires). Operating Current:If used with CT,the secondary current 5A or 1A is standard. POWER METER Wattmeters with built-in converter for 1 phase,3p 3W,3P 4W. Model:AM-96 AM-72 Class:1.5 Voltage:50V 100V 220V 240V 220/380V 240/4V Current:5a These meters are used with potential secondary voltage 100V voltage transformer or secondary current 5A CT.wattmeters with built-in converter for 3P 3W,3P 4W and single phase. MODEL:AM-96 AM-80 AM-72 AM-60 AM-50 Struction:Moving Coil,Moving Iron and Rectifier. Class:2.0 Name Specifications Remarks DC Ammeter uA mA 1K-10KA 1-50A Direct connection With EXt.Shunt DC Voltmeter mV V 1K-10KA 1-50A Direct connection With EXt.Resistor DC Ammeter mA 00A 1-50A 1K-0KA Direct connection With EXt.CT DC Voltmeter mA V 1K-380KV Direct connection With EXt.CT Frequency Meter Voltage:50-380V Frequency:45-55Hz 45-65Hz 55-65Hz Power Factor Meter Power Meter Voltage:50-380V Frequency:0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3ind Suitable for 1Por 3P3W Circuit Voltage:50-380V Current:0.2-5A With Current or Voltage Transformer Only AM-80 is available D-06

8 AM72 Digital Panel Meter 1. Application Digital panel meter which is various and artistic in appearance design is used for dual slope, high precise A/D changeover circuit and high light LED cassette setting specification. It is very convenient for user to fix the equipment. 2. Specification Description Direct input range Input current range Operation voltage Display range Class AC & DC digital voltage meter AC & DC digital Ampere meter Frequency digital meter AC tri-phase watt meter AC single-phase watt meter AC DC0-100V AC 10-20A DC 0-10A AC 10-2KHZ (20-300V) AC 0-100V AC 0-220V AC 5A AC 10-5A AC 220V 50/60Hz AC 220V 50/60Hz AC 220V 50/60Hz AC 380V 50/60Hz AC 110V 50/60Hz AC 220V 50/60Hz AC 110V 50/60Hz AC single-phase factor meter AC V AC 5A AC 220V 50/60Hz AM72-H, AM96-H AM72-Hz, AM96-Hz AM72-V, AM96-V AM72-I3, AM96-I3 AM72-V3, AM96-V3 AM72-A, AM96-A AM72-W, AM96-W AM48-I AM48-HZ AM48-H AM48-V AM-0V AM-0A AM-0Hz D-07

9 FL-2 Model FL-2 Current Divider Peripheral 1~50A 75~100A 0~200A 300A 500A 750A 1000A 00A D-08

10 FL-21 Model FL-21 Current Divider Peripheral 5~125A 0~200A 250~600A 800~00A 2000~2500A 3000~6000A D-09

11 MSQ-30 MSQ Current Transformers 1. MSQ-A Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: Mounting methods: 5A-0A 5A,1A VDE0414,BS7626,IEC KV 50-60KV 10VA 0.5,1.0 1th=60Ih FS5 by once-lead or by copper bar 2. Technical characteristics of current transformers: WITH BUSBAR Type MSQ-A Rated current(a) 30/5 40/5 20/5 60/5 75/5 80/5 100/5 120/5 125/5 200/5 250/5 Rated power(va) Class:0.5 Class:1 MSQ Weight (Kg) MSQ-40 WINDOWS TYPE Type Rated current(a) Rated power(va) Class:0.5 Class:1 Bar: 30x10mm conductor: ø20mm Weight (Kg) 30/ / / / MSQ-30 75/5 80/ / / / / /5 0.4 MSQ-60 WINDOWS TYPE Type Rated current(a) Rated power(va) Class:0.5 Class:1 Bar:40x10mm Conductor:ø30mm Weight (Kg) MSQ /5 0/ / D-10

12 MSQ MSQ MSQ-80 MSQ-100 MSQ-2000 D-11 Type Rated current(a) Rated power(va) Class:0.5 Class:1 Weight (Kg) 250/5 300/5 400/5 500/ MSQ-40 WINDOWS TYPE Bar:60x20mm Conductor:ø40mm Type Rated current(a) Rated power(va) Class:0.5 Class:1 Weight (Kg) 250/5 300/5 400/5 500/5 600/5 750/5 800/5 1000/ WINDOWS TYPE Bar:82x30mm. Conductor:ø80mm Type Rated current(a) Rated power(va) Class:0.5 Class:1 Weight (Kg) 750/5 800/5 1000/5 1200/5 00/ WINDOWS TYPE Bar:80x30mm.or 100x10mm. Conductor:ø60mm Type Rated current(a) Rated power(va) Class:0.5 Class:1 Weight (Kg) 00/5 1600/5 2000/5 2250/5 2500/5 3000/ MSQ-100 WINDOWS TYPE Bar:125x57mm.or 125x10mm. Conductor:ø60mm Type Rated current(a) Rated power(va) Class:0.5 Class:1 Weight (Kg) 00/5 2000/5 2500/5 3000/5 4000/5 5000/ MSQ-125 MSQ-60 MSQ-80

13 MR MR Current Transformers 1. MR Series MR-28 Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: 30A-5000A 5A,1A BS7626,IEC KV 50-60KV 5VA-VA 1.0, 3.0 1th=60 x Ih FS<5 2. Specification Class: Type Current ID(mm) OD(mm) TD(mm) MR-28 30/5A 60/5A MR /5A 250/5A MR-45 MR-45 MR /5A 400/5A 600/5A MR /5A 1600/5A MR /A 5000/5A Noted: For measuring currenttransformers, the accuracy class is designated by the highest permissible percentage current(ratio)error at the rated current perscribed for the ac curacy class concerned. 3. Outline Drawing MR-60 MR-85 D-12

14 RCT RCT Current Transformers 1. RCT Series RCT-25 Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: 30A-3000A 5A,1A IEC KV 50-60KV VA 1.0 1th=60 x Ih FS<5 2. Specification Model RCT-25 RCT-35 RCT-60 RCT-90 RCT-110 Primary/secondary /5A 20/5 30/5 40/5 50/5 60/5 75/5 100/5A 30/5 50/5 60/5 80/5 100/5 120/5 0/5 200/5 250/ 300/5A 300/5 400/5 500/5 600/5 800/5 1000/5 1200/5A 1000/5 1200/5 00/5 1600/5 2000/5A 2000/5 2500/5 3000/5 4000/5 5000/5A Dimension of case unit:mm Model RCT-25 RCT-35 RCT-60 RCT-90 RCT-110 RCT-60 A B V D E F G Outline Drawing RCT-110 D-13

15 DP DP Current Transformers 1. Split core current transformers DP series The DP series of current transformers have been especially designed to facilitate their installation in new or already existing networks. They may be installed without opening any cable or bus bar circuit. The connection of conventional CTs usually requires the interruption of the primary side circuit to pass cables or bus bars through the transformer core or to connect such cables to the primary terminals. The DP series transformers core may be easily opened and they may be installed and connected without any supply interruption, thus saving time and installation costs. The main features of DP transformers are: Small size and easy mounting. Wide inner window, allowing clamping of big cables or bus bars. Wide range of sizes to accomodate all the existing installations. High accuracy and reliability. 2. Split core current transformers DP series Primary current Secondary current Standard approval Maximum voltage Frequency Rated load Class Short-time thermal current Rated security coefficient 100A-5000A 5A,1A IEC44-1, BS /3kV 50/60Hz 1VA-30VA 0.5, 1.0, 3.0 Ith=100 x In FS<5 3. Specification Model A B C D E F G H I Weight(kg) DP DP DP DP DP D-14

16 DP 4. Outline Drawing D Model DP-23 DP-58 DP-88 DP-812 DP-816 Class:0.5 VA Class:1 VA Burden VA Nominal current ratio

17 MG26 Clamp Meter /1 VC /1 MG-28B DT-9250T 3 2/1 MG26 MG28 MG32 MG36 DT266 Multimeter SP-110 YX-360 TRD YX-360 TRN YX-360 TRES 3211 D+ DT-890D DT830B DT-830 D-16

18 DT-9205 Multimeter DT-9205 DT /1 DT /1 UT33B JT /1 RP DY-21A 3 2/1 NB4000P-2 3 4/3 DY /1 TM-902C 3 2/1 SP-D MF- 7001A GBW 7000 ZC11D-10 D-17

19 AM96 Temperature Controller AM72-4BIC (PO-010) AM (PO-019) AM (IN-050) AM (IN-037) AM (IN-038) AM (IN-039) AM (IN-040) AM AM AM AM-800 (IN-042) (IN-052) (IN-049) (IN-053) AM AM AM-TDA AM-TDB (PO-08) (PO-024) (PO-026) (PO-027) D-18

20 TC-1 Temperature Controller TC-1 (PO-03) TC-2 (PO-04) TC-3 (PO-05) JTC-902 (PO-06) JTC-903 (PO-07) SC-3 (PO-28) AM (PO-013) AM (PO-014) AM (PO-016) AM (PO-017) AM (PO-018) AM (IN-028) AM (IN-030) AM (IN-031) D-19

21 Others Thermocouple and Thermal Resistance NO: 10 NO: 05 NO fixed device style NO: 06 NO fixed device style NO: 07 Movable flange style NO: 08 Fixed thread style NO: 09 Fixed flange style Fixed thread protective tube style NO: 11 NO: 13 NO: NO: 12 NO: 14 NO: 16 NO: 17 NO: 18 D-20

22 HG140 PTC Heater -0W HG140 Compact heater in PTC technology Maintains minimum operating temperatures in enclosures Helps to prevent failure of electronic components caused by condensation and corrosion Heating power adjusts to ambient temperature Push connectors for quick and easy wiring DIN rail mountable CE Technical Data HG140 Operating voltage AC/DC V(also available in 12-48VDC) Heating element PTC resistor, self-regulating Heating body Anodized extruded aluminum Protection class I, test voltage 1600V Protection type IP20 Push-type terminals for stranded and solid wire 3 x Connection AWG ( mm 2 ) Mountina Clio for 35mm DIN rail(en 50022) Applications Electrical & Electronic enclosures Telecommunications systems Part.No Power 1) W 30W 45W Max.Current 2) 1.5A 3.0A 3.5A L 2.6 /65mm 2.6 /65mm 2.6 /65mm Weight 0.56 lbs(0.3kg) 0.66 lbs(0.3kg) 0.66 lbs(0.3kg) Display panels W A 5.5 /140mm 1.10 lbs(0.5kg) Automatic teller machines(atm S) Access & Parking control systems Ticket dispensers W 100W 0W 4.0A 4.5A 9.0A 5.5 /140mm 5.5 /140mm 8.7 /220mm 1.10 lbs(0.5kg) 1.10 lbs(0.5kg) 1.76 lbs(0.8kg) Determining the required heater size 1) at 68 F(20 C) ambient temparature. 2) Inrush current P H =(A x T x K)-P V P H =Required heating power for your application in Watts(W) P V =Heating power generated by existing components(e.g.a transformer)in Watts(W) A =Exposed enclosure surface area in square meters(m 2 ) T =Temperature differential between the desired minimum interior temperature and the Lowest possible external temperature of the enclosure in Kelvin(K), 1.8 F=1 C=1K K= Heat transmission coefficient of the enclosure material used: Painted steel: 5.5W/m 2 K Stainless steel: 3.7W/m 2 K Aluminum: 1.2W/m 2 K Polyester/Plastc: 3.5W/m 2 K For outdoor appllcations it is recommended to double the heating power Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end custome/buyer in its final application. D-21

23 Small PTC Heater HGK047 Compact heater in PTC technology Maintains minimum operating temperatures in enclosures Helps to prevent failure of electronic components caused by condensation and corrosion Heating power adjusts to ambient temperature DIN rail mountable CE Technical Data HGK047 Voltage/heating power See table Heating element PTC resistor, self regulating Heat sink Anodized extruded aluminum Protection class 1(grounded) Protection type IP54 Connection 3xAWG30(0.5mm 2 ),12 (300mm)length Mounting Clip for 35mm DIN rail (EN50022) Applications Electrical & Electronic enclosures Telecommunications systems Display panels Personnel booths Automatic teller machines(atm S) Access & Parking control systems Ticket dispensers Part.No Voltage VAC VAC VAC VAC VAC VAC Power 1) 10W 20W 30W 10W 20W 30W Max.Amps 2) 1.0A A 3.0A 1.0A 1.5A 1.5A 1) at 68 F(20 C) ambient temperature. 2) Inrush Length VDE 2.0 (50mm) 2.4 (60mm) 2.8 (70mm) 2.0 (50mm) 2.8 (70mm) 4.0 (100mm) UL Determining the required heater size P H =(A x T x K)-P V P H =Required heating power for your application in Watts(W) P V =Heating power generated by existing components(e.g.a transformer)in Watts(W) A =Exposed enciosure surface area in square meters(m 2 ) T =Temperature differential between the desired minimum interior temperature and the Lowest possible external temperature of the enclosure in Kelvin(K), 1.8 F=1 C=1K K= Heat transmission coefficient of the enclosure material used: Painted steel: 5.5W/m 2 K Stainless steel: 3.7W/m 2 K Aluminum: 1.2W/m 2 K Polyester/Plastic: 3.5W/m 2 K For outdoor applications it is recommended to double the heating power Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end custome/buyer in its final application. D-22

24 Small Thermostat KT011 Compact design Wide adjustment range Available with F or C scale Color coded trmperature dials DIN rail mountable Thermostat NC (normally closed): Thermostat opens at temperature rise. Comes with a red temperature dial. KT011 Thermostat NO (normally open): Thermostat closes at temperature rise. Comes with a blue temperature dial. Technical Data KT011 Part.No Contact type normally closed normally open normally closed normally open Scale on housing F F 0-60 C 0-60 C Sensor element: Maximum tolerance: Switching difference(hysteresis): Service life: Swiching capacity(max.load): Thermostatic bi-metal 7.2 F(4K) 12.6 F 5.4 F(7 C 3K) cycles A resistive/2a 120 VAC 10A resistive/2a 250 VAC DC 30W EM/EMC compliance: Connections: Mounting: Dimensions(H x W x D): Housing Weight: Protection type: Operatng temperature: EN ,EN ,EN pole terminal for AWG 14 max.(mm 2 ) Clip for 35mm DIN rail(en50022) 2.4 x 1.3 x 1.7 (60 x 33 x 43mm) Plastic 1.4oz(40g) IP20-4 to 176 F(-20 to 80 C) D-23

25 Compass Five-uses Compass Function Bound Scale Value Precision Five-uses compass Type97 Measure Azimuth Measure pitching Angle Compute distance Measure distance Mapping Measure 6000Mil 20Mil 20Mil Scale10:1 2% Scale(KM)1: : % 120mm 1mm Span0.5mm Function Bound Scale Value Precision Five-uses compass Type80 Measure Azimuth Measure pitching Angle Compute distance Measure map distance 6000Mil 50Mil 25Mil Scale100:1 5% Scale(KM)1: : % Coordinate Ruler Length80mm Short20mm 1mm Span0.5mm Service Instruction for Compass 1. Service Instruction for Compass Type Y/JZB97/80 Compass Type Y/JBZ97 is composed of coordinate rulers, mechanisms for azimuth, pitch angle (slope), map/real distances, etc. It can measure azimuth,pitch angle (slope), real/map distances and map coordinate, as well as draw simple maps based on measurements. 2. Structures & Performances D-24

26 Compass 3. Azimuth Measuring Mechanism It consists of magnetic needle system, azimuth dial, counter-clockwise digital azimuth dial (which would be clockwise as viewed from reflective mirror), sight port and head, etc. Full graduation of azimuth is 360 for outer circle and 6000 mil for inner circle. Procedures to measure azimuth angles in the open is as following: first open the compass, lay the counter-clockwise digital azimuth dial flat; then turn the reflective mirror to 45, and observe the azimuth angle from the mirror. The graduation pointed by the magnetic needle N (north) pole is read as azimuth angle. 4. Distance Measuring Mechanism It is a simple scaled distance measuring mechanism which measures distance by three sharp angles formed between sight port and sight head (see figures on the left). The length between the sight port and the middle sharp angle would be 10 A if taking the length between the sharp angles on each side as A, i.e., the scale is 10:1. Suppose the real width of B (assumed target to be measured) is 5m, and let it just sits between the sharp angles vertexes on each side, then the distance between the target and the measurer shuold be:10 x 5 =50m. 5. Slope Measuring Mechanism It includes slope dial, slope pendulum and reflective mirror. The measuring range is 90 Hold the compass as showed in the left figure, and aim at the target through sight port and head, then the slope grade from the target to the standing point could be read from the reflective mirror. The slope measurement could also be used to do simple level calibration. 7. Map Distance Measuring Mechanism It is composed of rolling wheel,distance dial and pointer,and is applicable to maps of-three different scales:1:10000, 1:50000, 1:25000.Measuring unit is kilometer. First roll the wheel and let the pointer point to 0, then put the compass on the map with the wheel sitting at the starting point (as shown in the left figure), and roll it along the designated route on the map until reach destination.the graduation pointed by the pointer is the map distance in kilometer. 8. Coordinate Rule It consists of one long ruler(120mm) and two short rulers (25mm), perpendicular to each other. Put the compass on the map with the long ruler parallel to the latitude while the short rulers parallel to the longitude (as shown in the left figure). Thus the detailed coodinate of the destination could be measured. Moreover, a simple map could be draw with a ruler, and the straight distance between two points on the map could be measured directly as: mm between two points map scale 100 =m 9. Maintenance 1. The compass must be kept away from ferromagnetic materials, high-voltage power cables and electromagnetic units either in use or in storage to avoid error or low sensitivity. 2. The compass shoule be stored in dry environment with good ventilation to avoid mildewing. 3. The reflective mirror and the digital azimuth dial should not be distorted of bent to avoid low accuracy. 4. White flannel could be used to slightly wipe contaminated surface(s) to keep clean and bright. 10. Product Kit 1. a compass; 2. a leather case; 3. a Service Instruction book; 4. a piece of flannel 5. a sile ribbon; 6. a plastic bag; 7. a Certification card. D-25

DIN-RAIL KWH Meter. Conform to EN Accuracy Frequency. Single phase. Rated impulse voltage Power consumption Temperature range

DIN-RAIL KWH Meter. Conform to EN Accuracy Frequency. Single phase. Rated impulse voltage Power consumption Temperature range ADM DIN-RAIL KWH Meter 1. Applications ADM is a kind of electronic Din rail watt-hour meter.it completely accords with relevant technical requirements of class 1 and class 2. It can accurately and directly

More information

AC Wattmeters and VArmeters

AC Wattmeters and VArmeters AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to

More information

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96 Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Minimum 18 in-lb Torque

Minimum 18 in-lb Torque CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Relcotech Transformer Manufacturer Sdn. Bhd. Flood Light. Description. Model: S MH70W S MH150W. Specification: Ingress Protection: IP65

Relcotech Transformer Manufacturer Sdn. Bhd. Flood Light. Description. Model: S MH70W S MH150W. Specification: Ingress Protection: IP65 tech Transformer Manufacturer Sdn. Bhd. Flood Light Model: S70150 - MH70W S70150 - MH150W Specification: Ingress Protection: IP65 Voltage: 220V ~ 240VAC 50Hz Lamp Wattage: 70W ~ 150W Holder Type: RX7s

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Technical information

Technical information Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary

More information

EMPAC Metal enclosed capacitor bank for wind applications

EMPAC Metal enclosed capacitor bank for wind applications EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

PLATINUM SERIES SWITCHBOARD METERS

PLATINUM SERIES SWITCHBOARD METERS PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

DIN Panel Meters Long Scale

DIN Panel Meters Long Scale DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

Panel Meters and Accessories Digital Panel Meter

Panel Meters and Accessories Digital Panel Meter Digital Panel Meter - SE - - X 2 3 4 5 6. Product code 2. Input Signal Mode 48--48X48 72--72X72 96--96X96 94--96X48 3. Function Mode I--current U--voltage P--active power Q--reactive power H--power factor

More information

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Control and Load Switch Specifications Bulletin Number 194E, 194L

Control and Load Switch Specifications Bulletin Number 194E, 194L Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13

More information

POWER METER. my2010 (c)

POWER METER. my2010 (c) POWER METER ELECTRIC POWER Electric power is the rate at which electric energy is transferred by an electric circuit. The SI unit of power is the watt. When electric current flows in a circuit, it can

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Current transformers. Current transformers

Current transformers. Current transformers Current transformers Current transformers Moulded case current transformer Moulded case CT, class 1 and 0.5 / 5 A Increased reliability Both halves of the housing overlap rather than butting up against

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

Portable Instruments. Bulletin 2000-E

Portable Instruments. Bulletin 2000-E Portable Instruments Bulletin 2000-E Usage Precautions Warning: Indicates usage precautions that must be read to ensure the safety of users and the equipment. Safety Instructions for Portable Instruments

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

Wide-Vue Analog Panel Meters

Wide-Vue Analog Panel Meters UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Data Sheet M Series 010.D.101.11 Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Application The moving - coil panel meters PSQ 48 in a housing of moulded thermoplastic

More information

1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4

1. Table of Contents T-LINE. Page. 1. Table for contents Description Current transformers type HF Product Overview 4 T-LINE 1. Table of Contents Page 1. Table for contents 2 2. Description Current transformers type HF 3 3. Product Overview 4 4. Measuring accuracy VA Burden 5 5. Survey chart 0,5 1 3, type HF3A, HF3B and

More information

Chapter 06 Accessories ACCESSORIES

Chapter 06 Accessories ACCESSORIES ccessories CCESSORIES 57 Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for the UMG measurement input Use in IT networks

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

EM DC Multi-Function DC Energy Meter

EM DC Multi-Function DC Energy Meter Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor

More information

ELECTRICAL MAINTENANCE

ELECTRICAL MAINTENANCE ELECTRICAL MAINTENANCE II PRACTICAL JOURNAL DATA 1 EXPERIMENT NO. 1 AIM: TO FIND VOLTAGE RATIO OF A GIVEN TRANSFORMER. CIRCUIT DIAGRAM: OBSERVATION TABLE: Sr.No. 1 2 3 4 Primary Voltage (V 1 ) Secondary

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130 Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 609) of compact design for snap-in panel mounting. Available

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

Basic Series Accessories Low Voltage Current Transformer Class 1

Basic Series Accessories Low Voltage Current Transformer Class 1 Low Voltage Current Transformer Class 1 Current Transformer Current transformers for direct mounting to bus bars or insulated round conductors. Application: indirect measurement of sinusoidal alternating

More information

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Quick selection table

Quick selection table Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /

More information

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual SDM320D / SDM320A DIN Rail Single Phase Two Wire Energy Meter with S0 Pulse Output (Four modular) User Manual ------------------- 1.1 Safety instruction 1.2 Introductions 1.3 Performance criteria 1.4 Specifications

More information

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions

More information

Cast resin transformers

Cast resin transformers Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information