1 Instruction Manual October 2007 milltronics MD-36 SPEED SENSOR
2 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: The user is responsible for all changes and repairs made to the device by the user or the user s agent. All new components are to be provided by Siemens Milltronics Process Instruments Inc. Restrict repair to faulty components only. Do not reuse faulty components. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 techpubs.smpi@siemens.com For a selection of Siemens Milltronics level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. For a selection of Siemens Milltronics weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. Siemens Milltronics Process Instruments Inc. 2007
3 Table of Contents Safety Notes...1 Safety Marking Symbols...1 The Manual...2 Technical Support...2 Milltronics MD-36 Speed Sensor...3 Specifications...4 Operation...6 MD-36/MD-36A Operation...6 MD-36 IS Operation...6 Dimensions...7 Aluminum Enclosure...7 Stainless Steel Enclosure...9 Mounting Floating Pulley Mount...11 Fixed Shaft Mount...13 Interconnection MD-36 Speed Sensor/Integrator Connection...14 MD-36 IS Speed Sensor/Isolator/Integrator Connection...15 Wiring Diagram (MD-36 IS only)...15 Maintenance Hazardous Area Installations Product Nameplate...17 Instructions Specific to Hazardous Area Installations...18 i
4 ii
5 Safety Notes 1 Special attention must be paid to warnings and notes highlighted from the rest of the text by grey boxes. WARNING: relates to a caution symbol on the product, and means that failure to observe the necessary precautions can result in death, serious injury, and/or considerable material damage. WARNING 1 : means that failure to observe the necessary precautions can result in death, serious injury, and/or considerable material damage. Note: means important information about the product or that part of the operating manual. Safety Marking Symbols In manual: On product: Description WARNING: refer to accompanying documents (manual) for details. 1. This symbol is used when there is no corresponding symbol on the product. 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 1
6 The Manual This instruction manual covers the installation, operation and maintenance of the MD-36 speed sensor. We strongly recommend that you read this manual, and any manual for a product used in conjunction with the MD-36 (such as a belt scale integrator), for proper installation and operation of any component of the weighing system. Adhering to the installation and operating procedures ensures a quick, trouble-free installation and allows for the maximum accuracy and reliability of your weighing system. Integrator and speed sensor instruction manuals are available for download from We always welcome suggestions and comments about manual content, design, and accessibility. Please direct your comments to techpubs.smpi@siemens.com. Technical Support Support is available 24 hours a day. To find your local Siemens Automation Office address, phone or fax number go to: Click on the tab Contacts by Product and then find your product group (+Process Automation > +Weighing Technology). Select the team Technical Support. Click on Next. Click on the appropriate continent, then select the country followed by the city. Click on Next. For on-line technical support go to: Enter the device name (MD-36) or order number, then click on Search, and select the appropriate product type. Click on Next. You will be prompted to enter a keyword describing your issue. Then either browse the relevant documentation, or click on Next to a detailed description of your issue to Siemens Technical Support staff. Siemens A&D Technical Support Center: phone fax Page 2 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
7 Milltronics MD-36 Speed Sensor The Milltronics MD-36 speed sensor is certified for use in hazardous and non-hazardous locations. The sensor, coupled to the motor or pulley shaft, converts the rotation of its input shaft into an encoded speed signal. The speed signal is transmitted to the integrating electronics for use in calculating the rate of material flow. Siemens provides a full range of electronic integrators: Milltronics BW 100 Milltronics BW 500 The MD-36 sensors can also be used with older model Siemens integrators: Compuscale Compuscale II Compuscale IIA Compuscale III Compu-M For further information about Siemens products, go to 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 3
8 Specifications Power MD-36/MD-36A: +15 V DC, 25 ma from integrator MD-36 IS: +5 V to +25 V DC from IS Switch Isolator Temperature 40 to +55 C ( 40 to +130 F) Input shaft rotation 0 to 2,000 rpm, bi-directional Output MD-36/MD-36A: open collector sinking output, max. 25 ma at 15 V DC 36 pulses / revolution 0 to 2,000 rpm = 0 to 1200 Hz MD-36 IS: load current: 0 to 15 ma 36 pulses per revolution 0 to 2000 rpm = 0 to 1200 Hz Input: Output 1:1 (speed ratio) Enclosure MD-36 and MD-36 IS: aluminum, rated NEMA 4/Type4/IP 65; 304 stainless steel MD-36A: aluminum; 304 stainless steel Page 4 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
9 Approvals MD-36: US/Canada CSA/FM Class II, Div. 1, Groups E, F, G, and Class III Europe ATEX II 2D, Ex td A21 IP65 T70 C CE MD-36 IS: US/Canada CSA/FM (with suitable IS Switch Isolator or Switch Amplifier): Class I, Div. 1, Groups A, B, C, D; Also Class II, Div. 1, Groups E, F, G system approval Europe ATEX II 2G, EEx ia IIC T6 (with suitable IS Switch Isolator) CE MD-36A: Europe CE Switch and Isolator Approvals Note: The Approval Ratings for the Proximity Switch and the IS Switch Isolator are the property of Pepperl+Fuchs. Copies of these Approval Certificates may be obtained at Proximity Switch Approval Ratings (Pepperl+Fuchs #SJ3.5-N) ATEX: II 2G, EEx ia IIC T6 (with suitable IS Switch Isolator) 1 CSA/FM (with suitable IS Switch Isolator or Switch Amplifier): Class I, Div. 1, Groups A, B, C, D; Also Class II, Div. 1, Groups E, F, G system approval IS Switch Isolator (Pepperl+Fuchs #KFA5-SOT2-Ex2 and #KFA6-SOT2-Ex2) ATEX: II 1G, [EEx ia] IIC CSA/FM: Class I, Div. 1, Groups A, B, C, D; Also Class II, Div. I, Groups E, F, G. Cable (optional) Belden 8770, 3 wire shielded, 0.82 mm 2 (18 AWG) or equivalent max. run 305 m (1000 ft) 1. Based on the ATEX rating of the NAMUR slotted sensor and CSA/FM system approvals. 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 5
10 Operation The speed sensor consists of a main shaft rotating in a bearing assembly fixed to the enclosure. The shaft turns a toothed disk divided into 36 teeth, each separated by a gap equal to the tooth width. In the MD-36/MD-36A, the encoder card is mounted so that the two optocouplers straddle the disk s teeth. MD-36/MD-36A Operation Power from the integrating device energizes the two optocoupler LEDs and feeds the 5 V DC regulator. The 5 V DC bus powers the logic circuitry and the output driver transistors. As the shaft rotates, the 36-tooth wheel modulates the light crossing within each optocoupler. The resulting outputs are two 50% duty cycle square waves that are phase shifted by 90 degrees electrical or ¼ cycle (one cycle of 360 degrees electrical corresponds to the width of one tooth and one gap). This configuration provides directional discrimination. The square wave outputs of the optocoupler are converted into clockwise (CW) and counterclockwise (CCW) square wave output signals by the intermediate logic. When the shaft rotates in a CW direction, the logic produces pulses at the CW output and the CCW output is disabled. When the shaft rotates in a CCW direction, the logic produces pulses at the CCW output and the CW output is disabled. The speed sensor is immune to any external vibration that would cause the toothed wheel to oscillate ¼ cycle (½ tooth width or 5 of shaft rotation) or less. MD-36 IS Operation The MD-36 IS Speed Sensor contains a Pepperl + Fuchs, NAMUR rated, inductive proximity sensor, model # SJ3.5-N, consisting of an oscillator and a coil. The oscillator creates a fequency which is emitted from the coil and out the face of the sensor. When a metal target enters this radiated field, eddy currents are indicated on this target. As the target moves closer to the sensor, the energy required from the oscillator increases. The IS switch isolator monitors the change in the oscillator load, triggering the output when a predetermined level is reached. Page 6 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
11 Dimensions Aluminum Enclosure Front View 71 mm (2.8 ) 142 mm (5.6 ) 71 mm (2.8 ) 1/2 NPT plug (two places) 142 mm (5.2 ) 218 mm (8.6 ) 56 mm (2.2 ) 112 mm (4.4 ) 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 7
12 Side View 117 mm (4.6 ) 61 mm (2.4 ) 16 mm (0.63 ) Ø shaft 84 mm (3.3 ) 124 mm (4.9 ) ref. 61 mm (2.4 ) 21mm (0.8 ) 213 mm (8.4 ) 114 mm (4.5 ) 6 mm (0.25 ) Ø shaft (two places) Page 8 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
13 Stainless Steel Enclosure Front View 19 mm (0.75 ) 76 mm (3.0 ) 152 mm (6.0 ) 152 mm (6.0 ) 76 mm (3.0 ) 239 mm (9.4 ) cable connector for 3 to 9 mm (0.125 to 0.25 ) o.d. cable 38 mm (1.5 ) 51 mm (2.0 ) 102 mm (4.0 ) 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 9
14 Side View 127 mm (5.0 ) 61 mm (2.4 ) 16 mm (0.63 ) Ø shaft 86 mm (3.4 ) 127 mm (5.0 ) (ref.) 76 mm (3.0 ) 21 mm (0.8 ) 216 mm (8.5 ) 114 mm (4.5 ) 6 mm (0.25 ) Ø shaft (two places) Page 10 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
15 Mounting WARNING: If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the user to use suitable precautions that prevent it from being adversely affected. The MD-36 speed sensor models can be coupled to a tail pulley, bend pulley, or motor shaft. There are two methods of attaching the sensor: floating and fixed. Floating Pulley Mount The input shaft and bearing assembly bear the weight of the speed sensor. The unit s arresting bracket stops the speed sensor from rotating with the shaft. The arresting bracket straddles a section of angle iron installed by the customer. Ensure the anti-rotation spring is fastened in place. see Pulley Shaft on page 12 pulley shaft MD-36 series B B Arresting bracket. Shorten if required. See Arresting Bracket on page12. spring angle iron (customer supplied) Notes: When mounting the speed sensor, ensure that the shaft alignment is true to avoid stresses on the shaft bearing. For preferred mounting locations, refer to the associated belt scale or weigh feeder application drawings. 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 11
16 Pulley Shaft M8 or 5/16-18 UNC set screw (customer supplied) 64 mm (2.5 ) 25 mm (1 ) 16 mm (0.630 ) min mm (0.633 ) max..254mm (.010") A A Arresting Bracket (B-B Cross Section) 127 mm (5 ) (approx) secure with hook or bolt angle iron arresting bracket anti-rotation spring Notes: When tail or bend pulley is not supplied by Siemens, machining on tail/bend pulley shaft (see Pulley Shaft above) to accommodate Milltronics speed sensor is done by customer. Arresting bracket is an anti-rotation device only and must not secure or support the speed sensor. Bearing life is greatly reduced if speed sensor is not free to "float." Use anti-rotation spring to prevent mechanical oscillation of speed sensor. Grease mating surfaces to prevent seizing. Page 12 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
17 Fixed Shaft Mount Side View motor shaft rubber hose hose clamp (typ) 16 mm (0.63 ) Ø shaft motor MD-36 Series 0.8 mm (0.03) max. shaft offset 13 mm (0.5 ) optimum dimension customer supplied mounting bracket (remove supplied arresting bracket) guard (to suit) Front View shaft rotation C W 8 mm (0.313 ) two places C C W 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 13
18 Interconnection Notes: Installation shall be performed only by qualified personnel in accordance with local governing regulations. Flexible conduit is recommended so excess stress is not applied to the shaft bearings. Use appropriate conduit and conduit fittings or cable glands to maintain NEMA or IP rating. Interconnection between the speed sensor and the integrator should be made with 3-wire shielded, 18 AWG cable (Belden 8770 or equivalent). Ground the shield at the integrator ONLY! MD-36 Speed Sensor/Integrator Connection MD-36 BW 100 BW 500 Description Terminal TB1 TB V DC Speed Out (CW) 1 2 (7) 2 (16) 2 Speed Out (CCW) 3 (7) 2 (16) 2 Common Ground G N/C 3 N/C 3 1. To determine direction of rotation, see Front View mounting on page Terminal positions in brackets denote that only one signal may be connected at one time. 3. N/C = No Connection Page 14 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
19 MD-36 IS Speed Sensor/Isolator/Integrator Connection MD-36 IS IS Switch Isolator (P&F #KFA5-S0T2-Ex2) BW 100 BW 500 Terminal Terminal TB1 TB Wiring Diagram (MD-36 IS only) Hazardous Area Siemens MD-36 IS S I G S I G Non-Hazardous Area IS Switch Isolator (Pepperl+Fuchs #KFA5-SOT2-Ex2 (customer supplied) S E I X G C 115 Vac See Note below. 2 conductor, 18 AWG shielded cable (customer supplied) Siemens Integrator SIG EXE- SHLD BW 500 BW 100 Refer to integrator installation diagram. Note: The 115 V version is shown. If 230 V is required, use isolation barrier Pepperl + Fuchs #KFA6-SOT2-Ex2. 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 15
20 Maintenance The speed sensor electronics do not normally require maintenance; however, a program of periodic checks would be beneficial. The enclosure and circuit board, or NAMUR sensor should be cleaned if necessary (only when the power is disconnected), using a vacuum cleaner and a clean, dry paint brush. Check all electrical contacts for corrosion and arcing. The speed sensor bearing should be periodically checked for corrosion, wear and seizing. The bearing s life is dependent upon the mounting, the severity of the application, and surrounding environment. If the bearings exhibit excess play or produce an unreasonably loud sound, the speed sensor should be returned to Siemens for repair. WARNING: Do not remove cover when an explosive dust atmosphere is present. Page 16 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
21 Hazardous Area Installations Product Nameplate Note: The nameplate shown is a typical example. Please check the nameplate on your device for your specific device configuration. 7ML19985DB02 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL Page 17
22 Instructions Specific to Hazardous Area Installations (Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6) The following instructions apply to equipment covered by certificate number Sira 06ATEX9304X: 1. For use and assembly, refer to the main instructions. 2. The equipment is certified for use as Category 2D equipment and may be used in hazardous zones 21 and 22 with dusts. 3. This equipment has a maximum surface temperature of T70 C (in a +55 C ambient). Refer to the applicable code of practice for selection of this equipment with respect to specific dust ignition temperatures. 4. The equipment is certified for use in an ambient temperature range of -40 C to +55 C. 5. Any cable or conduit entries must meet the requirements of European Directive 94/9/EC for Group II, Category 2D. 6. Cable should be selected in accordance with the applicable code of practice and such that its insulation can withstand the maximum surface temperature of the enclosure (T70 C). 7. The equipment has not been assessed as a safety related device (as referred to by Directive 94/9/EC Annex II, clause 1.5). 8. Installation and inspection of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice. 9. Repair of this equipment shall be carried out by suitably trained personnel in accordance with the applicable code of practice. 10. Components to be incorporated into or used as replacements in the equipment shall be fitted by suitably trained personnel in accordance with the manufacturer s documentation. 11. If the equipment is likely to come into contact with aggressive substances, then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. - Aggressive substances: for example, acidic liquids or gases that may attack metals or solvents that may affect polymeric materials - Suitable precautions: for example, regular checks as part of routine inspections or establishing from the material s data sheet that it is resistant to specific chemicals 12. Product marking shall include the warning: Do not open when an explosive dust atmosphere is present. Special Conditions for Safe Use The X suffix to the certificate number relates to the following special condition(s) for safe use: Cable or conduit entries shall comply with the requirements of the European Directive 94/9/EC for Group II, Category 2D and maintain the overall IP rating of the enclosure. Page 18 Milltronics MD-36 Speed Sensor INSTRUCTION MANUAL 7ML19985DB02
23
24 Siemens Milltronics Process Instruments Inc. 1954Technology Drive, P.O. Box 4225 Peterborough, ON, Canada K9J 7B1 Tel: (705) Fax: (705) Siemens Milltronics Process Instruments Inc Subject to change without prior notice *7ml19985DB02* Printed in Canada Rev. 2.0
Instruction Manual December milltronics RBSS
Instruction Manual December 2004 milltronics Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.
More informationInstruction Manual July milltronics MMI BELT SCALE
Instruction Manual July 2007 milltronics MMI BELT SCALE Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationBelt Scales Speed sensors
Overview is a low- to high-resolution shaft-driven speed sensor. Benefits Compact and economical Easy, low-cost installation Accurate belt speed detection Optional resolutions for measurement over a range
More informationBelt Scales Speed sensors
Overview is a low- to high-resolution shaft-driven speed sensor. Benefits Compact and economical Easy, low-cost installation Accurate belt speed detection Optional resolutions for measurement over a range
More informationInstruction Manual May milltronics MWL WEIGHT LIFTER
Instruction Manual May 2008 milltronics MWL WEIGHT LIFTER Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationInstruction Manual September milltronics A SERIES
Instruction Manual September 2003 milltronics A SERIES Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationInstruction Manual August milltronics MSI BELT SCALE
Instruction Manual August 2003 milltronics MSI BELT SCALE Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationSITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100
SITRANS AS 100 Instruction Manual September 2001 ITRANS AS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the
More informationInstruction Manual August milltronics MMI BELT SCALE
Instruction Manual August 2003 milltronics MMI BELT SCALE Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationMILLTRONICS UNIVERSAL SCALE NIVERSAL SCALE Rev. 1.2
MILLTRONICS UNIVERSAL SCALE NIVERSAL SCALE 33455530 Rev. 1.2 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationSTOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002
STOCKTROL-H VIBRATING LEVEL SWITCH Instruction Manual June 2002 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the
More informationMSI SINGLE IDLER BELT SCALE
MSI SINGLE IDLER BELT SCALE Instruction Manual PL-319 January 2001 33453190 Rev. 1.2 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect
More informationBelt Scales. Milltronics MUS Belt Scale. Operating Instructions 06/2012. Milltronics
Belt Scales Belt Scale Operating Instructions 06/2012 Milltronics Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and
More informationMWL Milltronics Weight Lifter. Instruction Manual June 2001
MWL Milltronics Weight Lifter Instruction Manual June 2001 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationBelt Scales. Milltronics MWL Weight Lifter. Operating Instructions 11/2011. Milltronics
Belt Scales Operating Instructions 11/2011 Milltronics Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationBelt Scales Accessories. Milltronics Test Chain. Operating Instructions 04/2013. Milltronics
Belt Scales Accessories Operating Instructions 04/2013 Milltronics Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and
More informationST-H SENSOR. Instruction Manual PL-527 January Rev. 1.6
ST-H SENSOR Instruction Manual PL-527 January 2001 33455270 Rev. 1.6 ST-H SENSOR Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the
More informationEZ-LIGHT K30L and K50L Intrinsically Safe Indicators
For use in hazardous areas with suitable zener barriers or galvanic isolators ATEX and IECEx certifications Fully sealed and rated to IP67/IP69K 1-, 2-, or 3-color models available; 5 available colors
More informationInstruction Manual May milltronics WEIGHFEEDER 800
Instruction Manual May 2008 milltronics WEIGHFEEDER 800 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationInstallation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707
Installation, Operating & Maintenance Instructions Norbro J-Switch as FM 00707 INTRODUCTION The J-Switch is a control package incorporating switches, sensors or pneumatic valves for actuator end of travel
More informationSITRANS WW300. Operating Instructions 03/2014
Operating Instructions 03/2014 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning
More informationGuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4
1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit
More informationEVZ Series (Small body) Explosion protected luminaire Operating Instructions
EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East
More informationOperating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series
Operating Instructions Valves Atkomatic 15800 Series ATEX and 30800 Series ATEX 15800 Series 30800 Series Atkomatic 15800 Series ATEX and 30800 Series ATEX Installation and Maintenance Instructions Revision
More informationInstruction Manual April milltronics WEIGHFEEDER 1200
Instruction Manual April 2008 milltronics WEIGHFEEDER 1200 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationOperating Instructions
Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6
More informationELT SCALE APPLICATIONS
BELT SCALE APPLICATION GUIDELINES Instruction Manual March 2002 ELT SCALE APPLICATIONS Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect
More informationType 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN
Type 3768 Inductive Limit Switch Mounting and Operating Instructions EB 8356 EN Edition February 2013 Note on these mounting and operating instructions These mounting and operating instructions (EB) assist
More informationElectropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN
Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationSolenoid Valves Type 3963
Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate
More informationEStrong-series Emergency Stop
Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand
More informationNorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy
NorthStar TM brand Instruction Manual SLIM Tach SL56 1.125 Thru-Shaft Diameter Magnetoresistive Encoder Designed for GE Wind Energy Patent Pending *791-1061-00* Rev. B Page 2 Table of Contents Chapter/Paragraph/Illustration
More informationType 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN
Type 3768 Inductive Limit Switch Mounting and Operating Instructions EB 8356 EN Edition February 2013 Note on these mounting and operating instructions These mounting and operating instructions (EB) assist
More informationLevel instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.
Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate
More informationLIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )
LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) Publication# 03revA Table of Contents Publication# 03revA Table Of Contents...
More informationPoint level measurement Capacitance switches
Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.
More informationFM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES
G2 SERIES G2 Industrial METER MODULES FM Approved Remote Kit Assembly (Part No. 113275-1) Maintains FM Approval. Accommodates fluid temperatures from -40 F to +250 F (-40 C to +121 C) depending on meter.
More informationInstallation Instructions for Load Management Kit A051C329
Instruction Sheet 12-2014 Installation Instructions for Load Management Kit A051C329 1 Introduction The information contained within is based on information available at the time of going to print. In
More informationINSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS
INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS Address all communications and shipments to: FEDERAL SIGNAL CORPORATION Industrial Systems Group 2645 Federal
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationEx m Solenoid Operator Type 0519
nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5
More information2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions
2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2562179B REV. B 818 Printed in USA 2013-2018 Federal Signal Corporation. All rights reserved. Limited Warranty
More informationLevel Measurement Point level measurement - RF Capacitance switches
Overview Configuration Installation is an inverse frequency shift capacitance level and material detection switch ideal for detecting interfaces, solids, liquids, toxic, and aggressive chemicals in critical
More informationSynergEX Panelboards for Hazardous Locations
SynergEX Panelboards for Hazardous Locations Installation & Maintenance Information 1. APPLICATION SynergEX panelboards provide short circuit protection for feeder or branch circuits to control lighting,
More informationFeatures. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)
817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global
More informationInstallation and Service Instructions for EX Series Explosion-proof Switches
Installation and Service Instructions for EX Series Explosion-proof Switches ISSUE 4 50009662 WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application
More informationOperating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PUA574 / PUA579(x)
Operating Instructions Installation Information METTLER TOLEDO MultiRange Weighing Platforms PUA574 / PUA579(x) www.mt.com/support Content 1 General information...4 2 Safety instructions...4 2.1 Safety
More informationType 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN
Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition July 2007 Contents Contents Page 1 Design and
More informationOperating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX
ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX
More informationM-0. M-0... series control, monitoring and signalling devices. Ex e
M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere
More informationSolenoid Operator 0516 / 1216
nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!
More informationK Series 3 Way Direct Acting Balanced Poppet Solenoid Valve
Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS
More informationTechnical Data. Dimensions
Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush
More informationBMRX Series ROTARY LEVEL CONTROL
BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0292 Rev C TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...
More informationActuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage
Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact
More informationLevel Measurement Point level measurement - RF Capacitance switches
Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable
More informationMAGNETIC FLOAT SWITCH
INSTALLATION AND OPERATING INSTRUCTIONS MAGNETIC FLOAT SWITCH 1. FUNCTIONAL DESCRIPTION: 2 2. AREA OF APPLICATION: 2 3. ASSEMBLY: 2 4. HAZARD NOTICES: 2 5. ELECTRICAL CONNECTION: 2 6. OPTIONS: 3 7. CAUTION:
More informationmodel ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION
MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.
More informationFlameproof Level Sensor (Flameproof F/S FP)
The Deeter F/S FP is magnetic float on a reed switch or Hall Effect sensor stem for control and indication of a liquid level while in a potentially explosive atmosphere. II 1/2G 2D Ex d IIC (*) Ga/Gb Ex
More informationSensor boxes SRBE Key features and product range overview
Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic
More informationYFC. Limit switch. Ex d. 24 operating head types
Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735
More informationProportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06
www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are
More informationTechnical Documentation
Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that
More informationLTX RF LEVEL SENSOR. Instruction Manual
LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004
More informationSITRANS P measuring instruments for pressure
Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with
More informationDisclaimer of Liability
Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by
More informationType 4-20mA Absolute Shaft Encoder & Optional Dragon Flow Sensor DLS-00X User Manual. hohner OPTICAL ENCODERS
Type 4-20mA Absolute Shaft Encoder & Optional Dragon Flow Sensor DLS-00X User Manual hohner OPTICAL ENCODERS Hohner Corporation 5536 Regional Road 81 Beamsville, Ontario Canada L0R 1B3 Canada Tel: 1 -
More informationSUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS
SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS Safety First In the maintenance and operation of mechanical equipment, SAFETY is the basic factor which must be considered at all times. Through
More informationInstruction Manual March ile-37 SENSING HEAD
Instruction Manual March 2003 ile-37 SENSING HEAD Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.
More informationSERIES 54 Inductive Proximity Sensor
SENSOR FEATURES > 2-wire DC sensor with minimum off-state current > ATEX-approval for zone 2 and zone 22 > High temp, UV, salt water resistant > Rugged metal base > IP66/67/69K > High impact protection
More informationInstallation Instructions for Appleton Mercmaster LED Luminaire
650559-000 INSTRUCTION SHEET Installation Instructions for Appleton Mercmaster LED Luminaire FOR PROPER AND SAFE INSTALLATION OF THIS PRODUCT, PLEASE READ THE FOLLOWING INSTRUCTIONS. Product Safety Signal
More informationProcess Protection Motion sensors
Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the motion and speed
More informationAccessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600
Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents
More informationFlorham Park, NJ USA Call (ASCO) for sales or service
Operator s Manual 4000 Series ATS Automatic Open-Transition Transfer Switches D design 30 230A, J design 260 600A, H-design 800 1200A, G-design 1600 4000A, F-design 4000A DANGER is used in this manual
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationINSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE
INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE INDEX INDEX... 2 REVISION INDEX... 2 INTRODUCTION... 3 GENERAL WARNINGS... 3 DESCRIPTION... 4 MAIN COMPONENTS... 5 MECHANICAL INSTALLATION... 6 INSTALLATION
More informationFlorham Park, NJ USA Call (ASCO) for sales or service
Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious
More informationØ 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:
, EN 60079 Electrical Specifications Code: Incremental Resolution: Up to 10,000 ppr (pulses per revolution) Supply Voltage: ** 4.5 Vdc min. to 30 Vdc max. (45 ma max. - no load) Low: 500 mv max. at 10
More informationMaterial: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-A EN 60079 Electrical Specifications Code: Incremental Resolution: 1 to 10,000 ppr (pulses per revolution) Supply Voltage: ** 4.5 Vdc min. to 30 Vdc max. (45 ma max.
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationType 4746 Electric or Pneumatic Limit Switch
Type 4746 Electric or Pneumatic Limit Switch Application Limit switches with inductive, electric or pneumatic contacts for attachment to pneumatic or electric control valves, to Type 4763 Electropneumatic
More informationIntegrated Control modules
.604.0 - Rev: 6, Page of Integrated Control modules QC4, QC42 and QC43 Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in
More informationWeighfeeders. Title page without bleed in RGB SITRANS WW500. Operating Instructions
Title page without bleed in RGB Bufferzone Find any font sizes for the text fields in the Panel "Paragraph styles"! The image must not touch with the Bufferzone. Background coolgray 20%, without history
More informationF3S-TGR-KM15/-KM16/-KH16
Safety door switches with partially or full stainless steel body F3S-TGR-KM1/-KM16/-KH16 This safety door switches use a stainless steel head or even a full stainless steel body to increase the robustness.
More informationM100F Incremental Motor Actuator R81F Interface Board
Installation Sheets Manual 121 Motor Actuators Section M Technical Bulletin M100F Issue Date 0493 M100F Incremental Motor Actuator R81F Interface Board Application Details Figure 1: M100 Motor Actuator
More informationOperating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)
Operating Instructions Installation Information METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x) www.mt.com/support Content 1. General information... 4 2. Safety instructions...
More informationDuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating
General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return
More informationILED Aquarius Illuminated Windsock. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...
More informationSingle Point Overfill Prevention Control Monitor Model: ST-15C Series Technical Manual
scully Single Point Overfill Prevention Control Monitor Model: ST-15C Series Technical Manual Duocept, Dynacheck, Dynamic Self Checking, Dynamic Faylsafe, Go Anywhere, Dynamic Self-Testing, IntelliCheck,
More informationType 2REX-A. Oil & Gas / Heavy Industry
Oil & Gas / Heavy Industry Type 2REX-A EN 60079 Electrical Specifications Code: Incremental Resolution: 1 to 10,000 ppr (pulses per revolution) Supply Voltage: ** 4.5 Vdc min. to 30 Vdc max. (45 ma max.
More informationIntegrated Control modules
.60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last
More informationGETTING STARTED GUIDE NI Channel Sinking Digital Input Module
GETTING STARTED GUIDE NI 9421 8-Channel Sinking Digital Input Module This document explains how to connect to the NI 9421. In this document, the NI 9421 with screw terminal, NI 9421 with spring terminal,
More informationMobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter
Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically
More informationLimit Switch Type 4747
Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical
More informationCCAI, CCAIF, CCAIF..H
CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside
More informationLevel Measurement Continuous level measurement - Capacitance transmitters
Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or
More information