GENERAL SPECIFICATIONS FOR:
|
|
- Christian York
- 5 years ago
- Views:
Transcription
1 GENERAL SPECIFICATIONS FOR: FUEL FILTRATION SYSTEMS 5A, 8A, 10A, 15A, 20A, 30A, &40A Equipment manufactured in the U.S.A. All specifications subject to change. Version 3.1
2 5A MODEL GENERAL SPECIFICATIONS v3.1 UltraPure 2
3 General Specification for Ultrapure Automatic Fuel Maintenance & Conditioning System 5A Model Input power requirement: 120/240V 1-phase, 208/480V 3-phase Rated flow rate: 5 GPM / 300 GPH (19 L/min) Designed for a 3,000gal (11,356L) diesel fuel storage facility 1. Control 1.1. Model 5A is controlled by PLC micro-processor Controller to be UL, cul and CE recognized Control unit will have a long life battery back-up system to provide software integrity during prolonged power loss, shipping and maintenance cycles All software is to be factory loaded prior to shipment and a permanent copy of each customer s software is to be maintained at the manufacture s location Software updates are to be provided through out equipment life time Digital 2 line LCD display interface for all user defined programming PIN code protection for user functions PLC has user selectable remote communication capabilities PLC memory shall maintain an event log with error review and tracking Power save mode to conserve power and extend unit life /120 volt control system. 2. Monitoring The following minimum functions will be monitored by the Ultrapure PLC: 2.1. Utility power available Door open/close Cycle table High Pressure Low Pressure Pump status Generator interlock Filter Status with automatic notification feature Water level Filter leak Pump leak Retention basin full Motor overload Exterior status lights Two dry contacts for facility interface i.e. Tank over-flow i.e. Tank leak detector v3.1 UltraPure 3
4 3. Filtration Ultrapure Model 5A is designed to maintain stored fuel to meet or exceed ASTM (D)975 using the following seven stage filtration Coalescence 3.2. Bulk water removal mesh filtration 3.4. Entrained water removal micron filtration 3.6. Emulsified water removal micron filtration 4. Conditioning 4.1. An additional propriety magnetic fuel conditioning element is to be provided as a system standard. 5. Mechanical features 5.1. Unit is of rigid steel construction Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment Double compartment containment vessel /4 HP pump motor ½ NPT plumbing inlet and outlet Double restrained hose and valve connections. 6. Multi-tank manifold (Optional) An optional multi-tank manifold shall be housed in a separate outdoor enclosure designed to match the 5A automatic fuel maintenance and conditioning system Each solenoid valve in the manifold is controlled by the 10A PLC Software will provide redundant failsafe operation for proper solenoid sequencing Double compartment containment vessel ¾ NPT plumbing inlets and outlets Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment. v3.1 UltraPure 4
5 8A MODEL GENERAL SPECIFICATIONS v3.1 UltraPure 5
6 General Specification for Ultrapure Automatic Fuel Maintenance & Conditioning System 8A Model Input power requirement: 120/240V 1-phase, 208/480V 3-phase Rated flow rate: 8 GPM / 480 GPH (30 L/min) Designed for a 10,000 gal (37,854 L) diesel fuel storage facility. 1. Control 1.1. Model 8A is controlled by PLC micro-processor Controller to be UL, cul and CE recognized Control unit will have a long life battery back-up system to provide software integrity during prolonged power loss, shipping and maintenance cycles All software is to be factory loaded prior to shipment and a permanent copy of each customer s software is to be maintained at the manufacture s location Software updates are to be provided through out equipment life time Digital 2 line LCD display interface for all user defined programming PIN code protection for user functions PLC has user selectable remote communication capabilities PLC memory shall maintain an event log with error review and tracking Power save mode to conserve power and extend unit life /120 volt control system. 2. Monitoring The following minimum functions will be monitored by the Ultrapure PLC: 2.1. Utility power available Door open/close Cycle table High Pressure Low Pressure Pump status Generator interlock Filter Status with automatic notification feature Water level Filter leak Pump leak Retention basin full Motor overload Exterior status lights Two dry contacts for facility interface i.e. Tank over-flow i.e. Tank leak detector v3.1 UltraPure 6
7 3. Filtration Ultrapure Model 8A is designed to maintain stored fuel to meet or exceed ASTM (D)975 using the following seven stage filtration Coalescence 3.2. Bulk water removal mesh filtration 3.4. Entrained water removal micron filtration 3.6. Emulsified water removal micron filtration 4. Conditioning 4.1. An additional propriety magnetic fuel conditioning element is to be provided as a system standard. 5. Mechanical features 5.1. Unit is of rigid steel construction Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment Double compartment containment vessel /4 HP pump motor ½ NPT plumbing inlet and outlet Double restrained hose and valve connections. 6. Multi-tank manifold (Optional) An optional multi-tank manifold shall be housed in a separate outdoor enclosure designed to match the 8A automatic fuel maintenance and conditioning system Each solenoid valve in the manifold is controlled by the 10A PLC Software will provide redundant failsafe operation for proper solenoid sequencing Double compartment containment vessel ¾ NPT plumbing inlets and outlets Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment. v3.1 UltraPure 7
8 10A MODEL GENERAL SPECIFICATIONS v3.1 UltraPure 8
9 General Specification for Ultrapure Automatic Fuel Maintenance & Conditioning System 10A Model Input power requirement: 120/240V 1-phase, 208/480V 3-phase Rated flow rate: 10 GPM / 600 GPH (38 L/min) Designed for a 20,000 gal (75708 L) diesel fuel storage facility. 1. Control 1.1. Model 10A is controlled by PLC micro-processor Controller to be UL, cul and CE recognized Control unit will have a long life battery back-up system to provide software integrity during prolonged power loss, shipping and maintenance cycles All software is to be factory loaded prior to shipment and a permanent copy of each customer s software is to be maintained at the manufacture s location Software updates are to be provided through out equipment life time Digital 2 line LCD display interface for all user defined programming PIN code protection for user functions PLC has user selectable remote communication capabilities PLC memory shall maintain an event log with error review and tracking Power save mode to conserve power and extend unit life /120 volt control system. 2. Monitoring The following minimum functions will be monitored by the Ultrapure PLC: 2.1. Utility power available Door open/close Cycle table High Pressure Low Pressure Pump status Generator interlock Filter Status with automatic notification feature Water level Filter leak Pump leak Retention basin full Motor overload Exterior status lights Two dry contacts for facility interface i.e. Tank over-flow i.e. Tank leak detector v3.1 UltraPure 9
10 3. Filtration Ultrapure Model 10A is designed to maintain stored fuel to meet or exceed ASTM (D)975 using the following seven stage filtration Coalescence 3.2. Bulk water removal mesh filtration 3.4. Entrained water removal micron filtration 3.6. Emulsified water removal micron filtration 4. Conditioning 4.1. An additional propriety magnetic fuel conditioning element is to be provided as a system standard. 5. Mechanical features 5.1. Unit is of rigid steel construction Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment Double compartment containment vessel HP pump motor ¾ NPT plumbing inlet and outlet Double restrained hose and valve connections. 6. Multi-tank manifold (Optional) An optional multi-tank manifold shall be housed in a separate outdoor enclosure designed to match the 10A automatic fuel maintenance and conditioning system Each solenoid valve in the manifold is controlled by the 10A PLC Software will provide redundant failsafe operation for proper solenoid sequencing Double compartment containment vessel ¾ NPT plumbing inlets and outlets Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment. v3.1 UltraPure 10
11 15A MODEL GENERAL SPECIFICATIONS v3.1 UltraPure 11
12 General Specification for Ultrapure Automatic Fuel Maintenance & Conditioning System 15A Model Input power requirement: 120/240V 1-phase, 208/480V 3-phase Rated flow rate: 15 GPM / 900 GPH (58 L/min) Designed for a 30,000 gal (113,562 L) diesel fuel storage facility 1. Control 1.1. Model 15A is controlled by PLC micro-processor Controller to be UL, cul and CE recognized Control unit will have a long life battery back-up system to provide software integrity during prolonged power loss, shipping and maintenance cycles All software is to be factory loaded prior to shipment and a permanent copy of each customer s software is to be maintained at the manufacture s location Software updates are to be provided through out equipment life time Digital 2 line LCD display interface for all user defined programming PIN code protection for user functions PLC has user selectable remote communication capabilities PLC memory shall maintain an event log with error review and tracking Power save mode to conserve power and extend unit life /120 volt control system. 2. Monitoring The following minimum functions will be monitored by the Ultrapure PLC: 2.1. Utility power available Door open/close Cycle table High Pressure Low Pressure Pump status Generator interlock Filter Status with automatic notification feature Water level Filter leak Pump leak Retention basin full Motor overload Exterior status lights Two dry contacts for facility interface i.e. Tank over-flow i.e. Tank leak detector v3.1 UltraPure 12
13 3. Filtration Ultrapure Model 15A is designed to maintain stored fuel to meet or exceed ASTM (D)975 using the following seven stage filtration Coalescence 3.2. Bulk water removal mesh filtration 3.4. Entrained water removal micron filtration 3.6. Emulsified water removal micron filtration 4. Conditioning 4.1. An additional propriety magnetic fuel conditioning element is to be provided as a system standard. 5. Mechanical features 5.1. Unit is of rigid steel construction Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment Double compartment containment vessel HP pump motor ¾ NPT plumbing inlet and outlet Double restrained hose and valve connections. 6. Multi-tank manifold (Optional) An optional multi-tank manifold shall be housed in a separate outdoor enclosure designed to match the 15A automatic fuel maintenance and conditioning system Each solenoid valve in the manifold is controlled by the 10A PLC Software will provide redundant failsafe operation for proper solenoid sequencing Double compartment containment vessel ¾ NPT plumbing inlets and outlets Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment. v3.1 UltraPure 13
14 20A MODEL GENERAL SPECIFICATIONS v3.1 UltraPure 14
15 General Specification for Ultrapure Automatic Fuel Maintenance & Conditioning System 20A Model Input power requirement: 120/240V 1-phase, 208/480V 3-phase Rated flow rate: 20 GPM / 1200 GPH (76 L/min) Designed for a 40,000 gal (151,416 L) diesel fuel storage facility 1. Control 1.1. Model 20A is controlled by PLC micro-processor Controller to be UL, cul and CE recognized Control unit will have a long life battery back-up system to provide software integrity during prolonged power loss, shipping and maintenance cycles All software is to be factory loaded prior to shipment and a permanent copy of each customer s software is to be maintained at the manufacture s location Software updates are to be provided through out equipment life time Digital 2 line LCD display interface for all user defined programming PIN code protection for user functions PLC has user selectable remote communication capabilities PLC memory shall maintain an event log with error review and tracking Power save mode to conserve power and extend unit life /120 volt control system. 2. Monitoring The following minimum functions will be monitored by the Ultrapure PLC: 2.1. Utility power available Door open/close Cycle table High Pressure Low Pressure Pump status Generator interlock Filter Status with automatic notification feature Water level Filter leak Pump leak Retention basin full Motor overload Exterior status lights Two dry contacts for facility interface i.e. Tank over-flow i.e. Tank leak detector v3.1 UltraPure 15
16 3. Filtration Ultrapure Model 20A is designed to maintain stored fuel to meet or exceed ASTM (D)975 using the following seven stage filtration Coalescence 3.2. Bulk water removal mesh filtration 3.4. Entrained water removal micron filtration 3.6. Emulsified water removal micron filtration 4. Conditioning 4.1. An additional propriety magnetic fuel conditioning element is to be provided as a system standard. 5. Mechanical features 5.1. Unit is of rigid steel construction Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment Double compartment containment vessel HP pump motor NPT plumbing inlet and outlet Double restrained hose and valve connections. 6. Multi-tank manifold (Optional) An optional multi-tank manifold shall be housed in a separate outdoor enclosure designed to match the 20A automatic fuel maintenance and conditioning system Each solenoid valve in the manifold is controlled by the 10A PLC Software will provide redundant failsafe operation for proper solenoid sequencing Double compartment containment vessel NPT plumbing inlets and outlets Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment. v3.1 UltraPure 16
17 30A MODEL GENERAL SPECIFICATIONS v3.1 UltraPure 17
18 General Specification for Ultrapure Automatic Fuel Maintenance & Conditioning System 30A Model Input power requirement: 208/480V 3-phase Rated flow rate: 30 GPM / 1800 GPH (114 L/min) Designed for a 60,000 gal (227,125 L) diesel fuel storage facility 1. Control 1.1. Model 30A is controlled by PLC micro-processor Controller to be UL, cul and CE recognized Control unit will have a long life battery back-up system to provide software integrity during prolonged power loss, shipping and maintenance cycles All software is to be factory loaded prior to shipment and a permanent copy of each customer s software is to be maintained at the manufacture s location Software updates are to be provided through out equipment life time Digital 2 line LCD display interface for all user defined programming PIN code protection for user functions PLC has user selectable remote communication capabilities PLC memory shall maintain an event log with error review and tracking Power save mode to conserve power and extend unit life /120 volt control system. 2. Monitoring The following minimum functions will be monitored by the Ultrapure PLC: 2.1. Utility power available Door open/close Cycle table High Pressure Low Pressure Pump status Generator interlock Filter Status with automatic notification feature Water level Filter leak Pump leak Retention basin full Motor overload Exterior status lights Two dry contacts for facility interface i.e. Tank over-flow i.e. Tank leak detector v3.1 UltraPure 18
19 3. Filtration Ultrapure Model 30A is designed to maintain stored fuel to meet or exceed ASTM (D)975 using the following seven stage filtration Coalescence 3.2. Bulk water removal mesh filtration 3.4. Entrained water removal micron filtration 3.6. Emulsified water removal micron filtration 4. Conditioning 4.1. An additional propriety magnetic fuel conditioning element is to be provided as a system standard. 5. Mechanical features 5.1. Unit is of rigid steel construction Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment Double compartment containment vessel HP pump motor ¼ NPT plumbing inlet and outlet Double restrained hose and valve connections. 6. Multi-tank manifold (Optional) An optional multi-tank manifold shall be housed in a separate outdoor enclosure designed to match the 30A automatic fuel maintenance and conditioning system Each solenoid valve in the manifold is controlled by the 10A PLC Software will provide redundant failsafe operation for proper solenoid sequencing Double compartment containment vessel ¼ NPT plumbing inlets and outlets Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment. v3.1 UltraPure 19
20 40A MODEL GENERAL SPECIFICATIONS v3.1 UltraPure 20
21 General Specification for Ultrapure Automatic Fuel Maintenance & Conditioning System 40A Model Input power requirement: 208/480V 3-phase Rated flow rate: 40 GPM / 2400 GPH (151 L/min) Designed for a 80,000 gal (302,833 L) diesel fuel storage facility 1. Control 1.1. Model 40A is controlled by PLC micro-processor Controller to be UL, cul and CE recognized Control unit will have a long life battery back-up system to provide software integrity during prolonged power loss, shipping and maintenance cycles All software is to be factory loaded prior to shipment and a permanent copy of each customer s software is to be maintained at the manufacture s location Software updates are to be provided through out equipment life time Digital 2 line LCD display interface for all user defined programming PIN code protection for user functions PLC has user selectable remote communication capabilities PLC memory shall maintain an event log with error review and tracking Power save mode to conserve power and extend unit life /120 volt control system. 2. Monitoring The following minimum functions will be monitored by the Ultrapure PLC: 2.1. Utility power available Door open/close Cycle table High Pressure Low Pressure Pump status Generator interlock Filter Status with automatic notification feature Water level Filter leak Pump leak Retention basin full Motor overload Exterior status lights Two dry contacts for facility interface i.e. Tank over-flow i.e. Tank leak detector v3.1 UltraPure 21
22 3. Filtration Ultrapure Model 40A is designed to maintain stored fuel to meet or exceed ASTM (D)975 using the following seven stage filtration Coalescence 3.2. Bulk water removal mesh filtration 3.4. Entrained water removal micron filtration 3.6. Emulsified water removal micron filtration 4. Conditioning 4.1. An additional propriety magnetic fuel conditioning element is to be provided as a system standard. 5. Mechanical features 5.1. Unit is of rigid steel construction Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment Double compartment containment vessel HP pump motor ½ NPT plumbing inlet and outlet Double restrained hose and valve connections. 6. Multi-tank manifold (Optional) An optional multi-tank manifold shall be housed in a separate outdoor enclosure designed to match the 40A automatic fuel maintenance and conditioning system Each solenoid valve in the manifold is controlled by the 10A PLC Software will provide redundant failsafe operation for proper solenoid sequencing Double compartment containment vessel ½ NPT plumbing inlets and outlets Outdoor rain and drip proof enclosure Hinged enclosure door with handle and gasket Durable powedercoat finish Mounting legs for ease of floor attachment. v3.1 UltraPure 22
23 WARRANTY FOR ULTRAPURE FUEL FILTERING, ECOPURE FUEL BLENDING, AND TRANSPURE INSULATING OIL CLEANING SYSTEMS This guarantee is extended only to the original purchaser, or if the purchaser is a reseller, the first customer they sell the equipment to, and will not be honored for any subsequent owner, user or transferee of this EQUIPMENT without obtaining written consent from Clinton Nevada, LLC. Clinton UltraPure will make every effort to fill orders within the time stated, but under no circumstances will Clinton Nevada, LLC be responsible for, or purchaser entitled to, any damages arising out of or owing to any delays whatsoever in shipment, delivery or installation. All electrical and mechanical components of each ECOPURE automatic fuel blender are guaranteed against defects in material & workmanship for a period of ONE YEAR from date of shipment provided all installation and operating instructions furnished with unit are adhered to. ULTRAPURE S liability shall be limited to repairing or replacing fob UltraPure s North Las Vegas Nevada plant, or allowing an equivalent credit at Clinton Nevada LLC s option for any part or parts, or material which may prove to be defective, provided the buyer gives Clinton Nevada prompt notice of the defect, and inspection, if required by Clinton Nevada, confirms such defect or defects. In no event will Clinton Nevada be liable for removal or reinstallation of any such part or parts and any costs incurred therewith. This remedy of repair, replacement or credit, at Clinton Nevada LLC s option, is the exclusive remedy hereunder. Clinton Nevada, LLC shall have no other liability to purchaser or any claims however arising and in no event shall Clinton Nevada, LLC be liable for general, special, incidental, consequential, or contingent damages under any warranty, express or implied, and all such liability is herby expressly excluded. Clinton Nevada, LLC makes no warranties, express or implied, of merchantability, fitness for a particular purpose or otherwise, with respect to the products covered by this warranty policy, except as expressly provided for herein. No employee, agent or distributor is authorized to make any warranty on behalf of Clinton Nevada, LLC. Clinton Nevada LLC s warranty does not cover minor leaks or drips, ordinary wear & tear, abuse, misuse, overloading, alterations, expendable parts & parts coming into abnormal contact with corrosive chemicals, fumes, moisture, or damage caused by factors beyond Clinton Nevada LLC s control. Clinton Nevada, LLC s failure to enforce any provision hereof shall not imply a waiver of that or any other provision. v3.1 UltraPure 23
Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC
Maintenance Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC www.fueltechnologiesinternational.com 03/01/2011 - Fuel Technologies FTI-5A Maintenance Section FTI - Fuel
More informationMaintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL
Maintenance Manual Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL 05/01/2016 Rev A Fuel Technologies FTI-5A Single Tank Maintenance Section FTI - Fuel Maintenance
More informationInstallation and Maintenance Manual
Installation and Maintenance Manual Automated Fuel Maintenance System FTI-2.8 FUEL TECHNOLOGIES INTERNATIONAL 01/01/2014 Rev A - Fuel Technologies - FTI-2.8 with ModBus OPERATIONS & MAINTENANCE CONTENTS
More informationMaintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC
Maintenance Manual WITH ONE SUBMERSIBLE PUMP Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com
More informationInstallation, Operating and Maintenance Manual
. Installation, Operating and Maintenance Manual TK 240 Tank Cleaning and Fuel Restoration System www.dieselfueltech.com Email: vernon@dieselfueltech.com Phone: +61 (0) 419 795 676 1 www.dieselfueltech.com
More informationManufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1
STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com
More informationUpdated: October 2012
T: (630) 794-5100 EMERGENCY POWER FUEL SYSTEMS Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com Updated: October 2012 The information
More informationStormPro BA Series Sump Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More informationTractor Applications Rapid Power Model Number
INSTALLATION Manual Tractor Applications Rapid Power Model Number John Deere 8130 to 8530 40605 John Deere 8230 (T) to 8430 (T) 40605 TABLE OF CONTENTS TROUBLESHOOTING: If you have questions during the
More informationService Guide JATCO Environmental Protection Tank Model J-7000
Service Guide JATCO Environmental Protection Tank Model J-7000 Listed below are a series of steps to follow if the JATCO tank fails to dump properly. #1. Be sure there is an adequate supply of gas pressure
More informationTERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)
TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for
More informationGC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY
GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for
More informationModel 1100 Turbine Flow Meter
Model 1100 Turbine Flow Meter INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 www.hedland.com TABLE
More informationFPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual
FPS-500 Fuel Polishing System Eliminates Microbial Contamination Operating Manual Stabilizes Fuel Removes Water & Sludge Prevents Tank Sediments Improves Engine Reliability Optimizes Fuel Quality Optimal
More informationMODEL 200 MULTI-JET FLOW METER
MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155
More informationPVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables
PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria
More informationMODEL 900 IMPELLER-TYPE FLOW METER
MODEL 900 IMPELLER-TYPE FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL LCO-8 125 PSIG RATED FILTER UNIT MODEL LCO-8 Table of Contents I. Installation...............................................................
More informationParts Manual Vermeer/ McLaughlin Mud System 230P
2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/
More information60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60
60 PSI Boost Gauge For Product Numbers: MT-DV01_60, MT-WDV01_60 Red: 12v Constant (un-switched) Source (+) Orange: 12v Dimmer (switched) Source (+) (optional) White: 12v Ignition (switched) Source (+)
More informationStormPro BCV400 Sewage Ejector Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More informationInline & 90 Live Swivels Fax:
Inline & 90 Live Swivels www.superswivels.com 763-784-5531 Email: sales@superswivels.com Fax: 763-784-7423 CW1602 Super Swivels was established in 1986. Our goal is to manufacture heavy-duty, leak free,
More informationPatron Call System. Scope s DataPage II Lite & NexCall Coaster. Operators/Installation Manual
Scope s DataPage II Lite & NexCall Coaster Operators/Installation Manual PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability of this equipment and
More informationAccessoriesAccessories
11 248 Hydraulic installation kit Hollow Piston Clamp with T-Bolt Figure 1 This expanded view of the diagram for a single hollow piston clamp shows the item numbers of the parts needed to connect this
More informationWATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S
WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S 466 S. SKYLANE DR. DURANGO, COLORADO 81303 970-259-2869 PHONE 970-259-2868 FAX www.stoneagetools.com
More informationWarranty Information North America
Publication No. 47705137 January 1, 2014 Warranty Information North America Industrial and Power Generation Power Systems Parts and Accessories Includes: Power Systems Warranty Statement Parts and Accessories
More informationPMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks
- 1 - PMD DRIVER RELOCATION KIT For 1994-1999 Chevy 6.5L Diesel Trucks Part# 1036520 -- Installation Instructions -- PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. - 2 - Kit Contents BD P/N#
More informationFCB-450, LCB-600, MCB-800
AIR CHAMP PRODUCTS User Manual FCB-450, LCB-600, MCB-800 Clutch-Brakes (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are
More informationINSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING
INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT LOAD CAPACITY: 500 LBS [227 kg] MANDATORY: LEAVE THIS MANUAL WITH LIFT OWNER WARNING 1. READ AND FOLLOW ALL INSTRUCTIONS. LIFT SAFETY
More informationMODEL 1100 TURBINE FLOW METER
MODEL 1100 TURBINE FLOW METER INSTALLATION & INSTRUCTION MANUAL 8635 Washington Ave. Racine, Wisconsin 53406 Phone: 800.433.5263 Fax: 800.245.3569 www.hedland.com 2 OPERATIONAL START-UP Fluid entering
More information7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide
7.3L POWERSTROKE BANJO BOLT KIT Fits 94-03 7.3L Powerstroke Diesel Installation Guide INSPECT CONTENTS OF THIS KIT THOROUGHLY BEFORE STARTING THE INSTALLATION PROCESS! IF YOU FIND A PROBLEM WITH YOUR PACKAGE:
More informationParts Manual Vermeer/ McLaughlin Mud System 230P
2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/
More informationRead this entire manual before operation begins.
Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............
More informationINSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD
INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE B-3724M ACTUATOR MANIFOLD MIDLAND MANUFACTURING CORP. 7733 Gross Point Road Skokie, Illinois 60077 Phone (847) 677-0333 FAX (847) 677-0138 WEBSITE
More informationRead this entire manual before operation begins.
Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............
More informationLevel Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions
Level Alert Model 2000 Multi-Switch Liquid Level Sensor Assembly and Installation Instructions Kit Form Each unit is provided in kit form with step-by-step instructions, making it extremely easy to custom
More informationJD-2 TOLL FREE UG August /2011
Instructions Manual Office Phone: 1-800-503-7534 / 305-868-1603 Fax: 305-866-2704 sales@skyfood.us - www.skyfood.us Warehouse Phone: 1-800-445-6601 / 973-482-5070 Fax: 973-482-0725 Juice Dispenser Model
More informationMODEL 200 MULTI-JET FLOW METER
MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Technical Toll-Free: 877.722.4631 Sales Toll-Free: 800.235.1638
More informationSPC-PANEL Simplex, Single Phase Pump Control Panel
Pump Installation and Service Manual SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner
More information½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #
29 July 2005 2003-04.5 Dodge Cummins OEM Bypass Lift Pump Kit # 1050227-1 - 2003-04½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 1050227 PLEASE READ ALL INSTRUCTIONS CAREFULLY
More informationFREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC
FREQUENTLY ASKED QUESTION SERIES BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC Ihave been getting a bunch more comments and questions from customers
More informationType Flexair Pneumatic Pressure Control Valves
Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Type Flexair Pneumatic Pressure Control Valves Catalog pages from
More informationPump Installation and Service Manual HRS Hydromatic Retractable System
Pump Installation and Service Manual HRS Hydromatic Retractable System NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party
More informationSTAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications
STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications Manufactured in ISO9000:2000 Facility Manufactured to ASTM/ASME A182/SA182 Items conform
More informationFlo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide
Flo-Way R Solids Impact Flow Meter Measure Granular or Powdered Material Stand Alone or Connect to Other Devices for Blending Used by Successful Producers World-Wide Visit our website: www.beltwayscales.com
More informationPFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250
PFS Rotameter 09/2018 Rev. 0 Variable Area Flowmeter Instruction Manual PFS-RM200, RM230, RM250 Please note: This instruction manual provides detailed information and instructions that must be read, understood
More informationUSER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)
USER MANUAL NEMA 48C Flange Mounted, Enclosed, Clutch Brake FMCBE Model 500 (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual
More information4-Ton Electric Log Splitter
4-Ton Electric Log Splitter Questions: Support@Powrkraft.com PK65556 2 18ga. @ 20ft, 16ga. @ 50ft, 14 ga. @ 75ft. 12ga @ 100ft, 10ga @ 200ft These are minimum cord requirements. 13-16 Model Number 65556
More informationPRO JACK 4500 ROLLING BRIDGE JACK 4,500 POUND CAPACITY. PARTS MANUAL P/n NRJ450BK
PRO JACK 4500 ROLLING BRIDGE JACK 4,500 POUND CAPACITY PARTS MANUAL P/n NRJ450BK 2007 RJ-45 (M) PARTS LIST Item # Part Number Description Qty 1 NRJ45-1000 Bottom Tray 1 2 NRJ45-2100 Outer Scissor 1 3
More informationInstallation and Operations Manual
Installation and Operations Manual Automated Fuel Maintenance System MODEL FTI-2.8 FUEL TECHNOLOGIES INTERNATIONAL 03/01/2011 Rev B - Fuel Technologies - FTI-2.8 OPERATIONS & MAINTENANCE CONTENTS Installation
More informationDUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual
Installation Instructions Tech Support: 856.768.8300 TechSupport@GlowShiftGauges.com DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual (1) Gauge (2) Controllers
More informationIon Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power
Page 1 of 8 equipment and follow handling procedures per OSHA 29 CFR 1910.1030 when handling equipment after waste water source has been connected to system. WARNING: Risk of Asphyxiation. Installer(s)
More informationModel C230 Pump Controller
MANUAL Model C230 Earthsafe Systems, Inc. 7553 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com March 1, 2010 The information contained herein is
More informationDODGE CUMMINS MK-2 Micro-Kleen System
Installation Manual P/N MK20306 2003-07 DODGE CUMMINS MK-2 Micro-Kleen System Installation Instructions P/N MK20306 2 Micron Fuel Filter Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION
More informationDODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #
2/15/2006 2000-2002 Dodge Cummins OEM Bypass Lift Pump Kit # 1050229-1 - 2000-02 DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 1050229 PLEASE READ ALL INSTRUCTIONS CAREFULLY
More informationOPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II
Document No.: LMSII_V100_OM Page 1 of 8 LMS II Document No.: LMSII_V100_OM Page 2 of 8 1. Operation: When the wet well level rises above the on level set point, the lead pump will start after an adjustable
More informationAdapter. Owner's Manual & Warranty. Item# JSFSA. Compatible with Weego Jump Starter Battery+ Models JS 12 & JS 18
Adapter Item# JSFSA Owner's Manual & Warranty Compatible with Weego Jump Starter Battery+ Models JS 12 & JS 18 Learn About Your Wee go 12V DC Adapter! There are so many tools and accessories you can power
More informationAPCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES
APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES Instruction D12043 June 2016 DeZURIK Instructions These instructions provide installation, operation and maintenance information for APCO CRF-100A Rubber
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 4 200 PSIG RATED FILTER UNIT Table of Contents I. INSTALLATION.................................................................
More informationTHIS IS A HIGH PERFORMANCE PRODUCT - USE AT YOUR OWN RISK!!!
9/15/08 6.6 GM Duramax Aurora 5000 Turbo Installation Guide THIS IS A HIGH PERFORMANCE PRODUCT - USE AT YOUR OWN RISK!!! Do not use this product until you have carefully read the following agreement. This
More informationUse/Installation Guide
Use/Installation Guide 5 Series Outdoor Gas Grill Carts IMPORTANT: PLEASE READ AND FOLLOW 1. Before beginning, please read these instructions completely and carefully. 2. Do not remove permanently affixed
More informationAPCO ASR-400/450 SEWAGE AIR RELEASE VALVES
APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage
More information5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com No. 2077650(1) 5874SS/5874PB/5874PBF/VRK5874/PBA6/
More informationNEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL
NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610-0012 Rev B Manual No. 610-0012 REV B Neo-Dyn 28150 Industry
More informationParts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )
2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual V100G Vacuum
More informationDODGE CUMMINS Arctic-Heat Grid Relocation Kit
Installation Manual P/N 07509-350-GRK 2007.5-09 DODGE CUMMINS Arctic-Heat Grid Relocation Kit Installation Instructions P/N 07509-350-GRK GDP Arctic-Heat Grid Heater Installation PLEASE READ ALL INSTRUCTIONS
More informationAll products subject to this warranty must be returned for examination, repair or replacement to:
Limited Warranty The software and sensors are warranted by the manufacturer, Toledo Integrated Systems, to be free from defects in workmanship for one year from the date of manufacturer s shipment. This
More informationAir-Boss VP Intake Plenum
Installation Manual P/N 98502-ABIP 98.5-02 DODGE CUMMINS Air-Boss VP Intake Plenum Installation Instructions P/N 98502-ABIP GDP Air-Boss VP Plenum Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
More informationNEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH
NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev
More informationPART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION
PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION 500 LB. [227 kg] MAXIMUM CAPACITY MANDATORY LEAVE THIS MANUAL WITH LIFT OWNER - WARNING- IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS.
More informationASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly
ASSEMBLY / OPERATION INSTRUCTIONS 1,500LB CAPACITY Low Profile Motorcycle Dolly Model: 03-CG1500-01(B1) WARNING BEFORE USE PLEASE READ ALL WARNINGS AND INSTRUCTIONS TO PREVENT SERIOUS INJURY Drop-Tail
More informationSOLAR DASH CHARGING SYSTEM USER GUIDE
SOLAR DASH CHARGING SYSTEM Doc 1.01 INST049 INSTALLATION STEP 1 Place 20 watt solar panel in the dash of the vehicle facing up. Note: For ideal results position the vehicle in a manner in which the solar
More informationAPCO CVS-6000 CONVERTIBLE SWING CHECK VALVES
APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES Instruction D12009 December 2012 Instructions These instructions provide installation, operation and maintenance information for APCO CVS-6000 Convertible Swing
More informationPVI 60KW, PVI 82KW, PVI 95KW
PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy
More informationUniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual
UniTorq UTQ 1.5 6.4 Quarter-Turn Actuator Installation and Operation Manual Thank you for purchasing our UTQ 1.5-6.0 Electric Actuators Before installation or operation of the actuator carefully review
More informationWarranty. Seating Arrangements. AB Limited Warranty
Seating Arrangements Please find all the information of the Seating Arrangements, in the Owner s Manual section at our webpage: www.abinflatables.com. years against separation and subsequent loss of air,
More informationCabling for power, control, and video must be run to the installation site before the mount is installed.
User Installation User Guide Guide & Operation Manual V940D V-20B-A-2 V940D Mounting Kits Mounting Pole Mounting Kits Adapter X532-11-00 Vicon Industries Inc. does not warrant that the functions contained
More informationDual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev
Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How
More informationRACE PPE Manifolds and Up-Pipes
RACE ONLY High-Flow Exhaust Manifolds with Up-pipes GM DURAMAX 6.6L 2001-2015 DISCLAIMER OF LIABILITY This is a performance product which increases horsepower above factory specifications. Additional horsepower
More informationInstallation / Operation Instructions Sunnex ORION Series Exam Lights
Installation / Operation Instructions Sunnex ORION Series Exam Lights OR-120 OR-127 OR-220 OR-227 Models: OR-300 OR-400 OR-500 OR-600 1. APPLICATIONS The Sunnex ORION Series light was designed specifically
More informationDodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -
29 September 2005 Dodge Cummins Low Fuel Pressure Alarm Light Kit 1081130-33 1 1999-2005 Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual - Part Number Sequence: 1081130 Red 1081133
More informationAtlas PV-9WP Addendum
Atlas PV-9WP Addendum 9,000 lb. Capacity Two-Post Overhead Lift The Atlas PV-9WP above ground hoist is 6 inches wider than the Atlas PV-9P, giving it an overall width of 141 (11 9 ) and a drive thru width
More informationTachometer. English. Users Manual
931 Tachometer Users Manual English PN 3409877 January 2009 2009 Fluke Corporation, All rights reserved. Printed in Germany. Specifications are subject to change without notice. All product names are trademarks
More informationST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:
ST-70 CONTROL OPERATING MANUAL REVISION DATE: 05-15-07 PART#: 98-0002-09 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE DEPARTMENT. IF FURTHER HELP
More informationValue Super Filter Max Installation Manual
Value Super Filter Max Installation Manual Barrie, Ontario, Canada, L4N 4Y8 www.excaliburwater.com EXCALIBUR VALUE SUPER FILTER MAX INSTALLATION MANUAL INSTALLATION PROCEDURES: The Value Super Filter Max
More informationSingle Post Caliper Brake VC500
Single Post Caliper Brake VC500 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical
More informationESE Series Cast Iron Sewage Pumps
Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................
More informationREAD THIS MANUAL CAREFULLY BEFORE USING THE PUMP
OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This
More informationTerms and Conditions
Terms and Conditions GUARANTEE: All Brighton-Best International, Inc. products are manufactured to rigid quality control standards which meet or exceed industry standards. Records and tests pertaining
More informationDodge Cummins 5.9L 24 Valve Edge Products EZ Module Installation Instructions & Manual
1998.5-2002 Dodge Cummins 5.9L 24 Valve Edge Products EZ Module Installation Instructions & Manual OLD P/N s: EZD1000 / EZD1000A / EZD1000B NEW P/N s: 30200 / 30201 2007 Edge Products All rights reserved.
More informationHP190SL Series Slimline Radon Fans
Installation and Operation Manual Item #: 412843 Rev Date: 070113 HP190SL Series Slimline Radon Fans United States 10048 Industrial Blvd., Lenexa, KS, 66215 Tel.: 800.747.1762 Fax: 800.487.9915 Canada
More informationInstallation & Operating Instructions for Zone Valve Boxes & Ball Valves
V Series Zone Valve Box EV Series Zone Valve Box Ball Valve Page 1 of 9 Introduction The Powerex ball valves and zone valve boxes are cleaned for use with oxygen. Each valve is tested for leakage in both
More informationDIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L
DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L Thank you for purchasing DigiGauge by ZAETECH Disclaimer DigiGauge is for show and off road use only. By using this
More informationDISTRIBUTED BY TULSA CHAIN.COM, LLC.
OPERATOR S MANUAL PUSH BEAM TROLLEY 0.5 TON THROUGH 10 TON GEARED BEAM TROLLEY 1 TON THROUGH 30 TON BEAM TROLLEY WITH CLAMP 1 TON THROUGH 5 TON These products meet or exceed the following standards: CE
More informationDODGE CUMMINS Air-Boss CR Intake Plenum
Installation Manual P/N 0307-ABIP 2003-07 DODGE CUMMINS Air-Boss CR Intake Plenum Installation Instructions P/N 0307-ABIP GDP Air-Boss CR Plenum Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
More informationParts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )
2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual V100G Vacuum
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
PAGE: 1 of 8 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 6 BAG/CARTRIDGE CONVERTIBLE 150/300 PSIG RATED FILTER UNIT Table of Contents I. Installation...............................................................
More informationPush Button Pendants Manual 80 Series
Push Button Pendants Manual 80 Series 1 960400.4.0 80 SERIES PENDANTS MANUAL CONDUCTIX INCORPORATED The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES,
More informationGETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL
GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com
More informationBC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO
MEX (55) 5 6 QRO (44) 95 7 60 MTY () 54 0 BC Brake Caliper (i) FORM NO. L-0066-B-040 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this
More information