OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

Similar documents
Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

SUNC3000 / Item #40885

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ESE Series Cast Iron Sewage Pumps

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

SUBMERSIBLE SUMP PUMPS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

HALLMARK INDUSTRIES INC

SUBMERSIBLE SUMP PUMPS

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

PRE-PLUMBED SEWAGE SYSTEM

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

GARDEN HOSE UTILITY PUMP

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE

Submersible Effluent Pump

Matala. VersiFlow Series. Instruction and Maintenance Manual

SHALLOW WELL JET PUMP

StormPro BA Series Sump Pump

ON-SITE WASTEWATER PRODUCTS

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

STAR STOP SHALLOW WELL JET PUMP

M-3025CB-AV Fuel Pump

Ion Technologies WC33 Submersible Sump Pump

Submersible Sewage Ejector Pump

Sump / Effluent Pump

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

SUPER PUMP OUT SYSTEM

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

StormPro BCV400 Sewage Ejector Pump

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

STEP-BY-STEP INSTALLATION GUIDE

GeyserMax-Flow Series

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

INSTALLATION & OPERATION MANUAL

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

Installation Manual. Q Series Quadplex Grinder Systems. Contents

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

SUBMERSIBLE SWIMMING POOL DRAINER

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Powerful & Intelligent Submersible Pumps

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Owner s Manual Drill and Light Weight Portable Utility Pumps

Installation & Operating Manual

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

OBE, OBEXU, ON BOARD Battery Chargers

2460 / 2472 / Series Simplex Grinder Systems

OWNER S MANUAL CONVERTIBLE JET PUMP

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

SUBMERSIBLE PUMP HSE RANGE

OBAE, OBAEXU, ON BOARD Battery Chargers

G8 Portable Fuel Transfer Pump Owner s Manual

1/2 HP CAST IRON TRANSFER PUMP

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

QSSE, QSSEX INDUSTRIAL Battery Chargers

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

SUBMERSIBLE MINI-PUMP

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

STOCK No. 53DH04 MODEL 6EC-CIA-SFS STOCK No. 53DH05 MODEL 6EC-CIM STOCK No. 53DH06 MODEL 10EC-CIA-SFS. Installation Guide

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

LAWN SPRINKLER, IRRIGATION PUMP

SP40 Submersible Sewage Ejector Pump

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Portable Utillity Submersible Pump Model: UT17-1/6 Hp, 120 Volt, 60Hz, 1Ph

Model E75STVT. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

115 VOLT TRANSFER PUMP

THERE IS NO OTHER EXPRESS WARRANTY.

Ion Technologies ES45 Effluent Pump

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Transcription:

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz PFSPPPP Series PFSPCPC Series ISP No: PFSP33_50-4/2016

PFSPPPP33 / PFSPCPC50 Series General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information could cause serious bodily injury, death and/or property damage. Each Power-Flo pump is individually factory tested to insure proper performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service. IMPORTANT - Power-Flo Pumps and Systems is not responsible for losses, injury or death resulting from failure to observe these safety precautions, misuse, abuse or misapplication of pumps or equipment. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury, and/or death. before servicing. ALWAYS disconnect the power to the pump Release all pressure and drain all water from the system before servicing any component. Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing. Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water before disconnect the power. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury, and/or property damage. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this pump is not permitted. working with pumps. Wear safety goggles at all times when These units are designed for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death. Ensure that the electrical circuit to the pump is protected by a 15 Amp, fuse or circuit breaker. Do not lift the pump by the power cord. Know the pump and its applications, limitations, and potential hazards. IMPORTANT! - Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure. IMPORTANT! - Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and debris. Disconnect the pump from the power supply before inspecting. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational Safety and Health Administration (OSHA) guidelines must be followed. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in. Ensure the electrical power source is adequate for the requirements of the pump. IMPORTANT! - This pump is made of highstrength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Power-Flo is a registered trademark of Power-Flo Technologies Inc. Alteration Rights Reserved. 3/15, 8/15, 4/16 2

PFSPPPP33 Series Features: General purpose pump for residential, light industrial and commercial sump applications Specifications DISCHARGE: 1-1/2 NPT Male, Vertical, 1-1/4 with Adapter LIQUID TEMPERATURE: 32-77 F MOTOR HOUSING: Epoxy-coated aluminum alloy. IMPELLER: Corrosion-resistant, reinforced Thermoplastic PUMP BASE: Corrosion-resistant, reinforced Thermoplastic, Top suction design filters debris and minimizes clogging. SHAFT: Stainless Steel HARDWARE: Stainless steel GASKET: Rubber SEAL: Single mechanical, rubber and stainless steel UPPER BEARING: Single row, ball, oil lubricated LOWER BEARING: Single row, ball, oil lubricated POWER CORD: SJTW, 18AWG/3C Cord, with plug. MOTOR: Energy efficient Permanent Split Capacitor (PSC), Oil Filled, Class B insulation, Continuous duty (water depth must be at least 6 to prevent motor from overheating), Auto reset thermal overload protector, Circuit requirments 15 AMPS. LEVEL CONTROL: Vertical, Mechatronic, Normally Open (N/O), reinforced thermoplastic, SJTW 18AWG/3C, 10 Ft. cord with, Piggy-back plug, On point - 8.4, Off point - 4 P/N: PFEVS10D1810P1 WARRANTY: 3 year Submersible Sump Pump 1-1/2 Discharge, 1/4 Spherical Solids Vertical Float MODEL HP Hz Volts/Ph RPM FL AMPS Cord Length PFSPPPP3328601F10 1/3 60 115/1 3450 7.6 10 ft 9 lbs Wt. HEAD in Ft 0 Ft 5 Ft 10 Ft 15 Ft 20 Ft 25 Ft FLOW Gallon/Minute 60 57 50 42 32 17 FLOW Gallon/Hour 3600 3400 3000 2500 1900 1000 Max Lift Max Pressure 28 Ft 12.4 psi PF TYPE U, SP, SW Motor Housing Impeller Type Suction Plate Type Motor HP 25, 33, 50, 75, 1 30 50 Voltage 1 or 2 Float Switch Type M, F, T Cord Length 10, 20 Power-Flo U = Utility SP = Sump Pump SW = Sewage Pump 25 = 1/4 HP 33 = 1/3 HP 50 = 1/2 HP 75 = 3/4 HP 1 = 1 HP Shut Off Head (ft) Max Flow (Gal) 1 = 115 V 2 = 230V M = Manual F = Fixed Vertical T = Tethered 10 Ft 20 Ft EXAMPLE: PFSPCPC3330501T10 - Power-Flo Pumps - Sump Pump - Cast Iron Motor Housing - Plastic Impeller - Cast Iron Suction Plate - 1/3HP - 30 Shut Off Head - 50GPM Max Flow - 115 Volt - Tethered Float - 10 Cord 3

PFSPPPP33 Series Performance & Dimensions Model: PFSPPPP3328601F10 4

PFSPPPP33 Series Features: General purpose pump for residential, light industrial and commercial sump applications Specifications DISCHARGE: 1-1/2 NPT Male, Vertical, 1-1/4 with Adapter LIQUID TEMPERATURE: 32-77 F MOTOR HOUSING: Epoxy-coated aluminum alloy. IMPELLER: Corrosion-resistant, reinforced Thermoplastic PUMP BASE: Corrosion-resistant, reinforced Thermoplastic, Top suction design filters debris and minimizes clogging. SHAFT: Stainless Steel HARDWARE: Stainless steel GASKET: Rubber SEAL: Single mechanical, rubber and stainless steel UPPER BEARING: Single row, ball, oil lubricated LOWER BEARING: Single row, ball, oil lubricated POWER CORD: SJTW, 18AWG/3C Cord, with plug. MOTOR: Energy efficient Permanent Split Capacitor (PSC), Oil Filled, Class B insulation, Continuous duty (water depth must be at least 6 to prevent motor from overheating), Auto reset thermal overload protector, Circuit requirments 15 AMPS. LEVEL CONTROL: Wide Angle Tethered, Mechanical, Normally Open (N/O), reinforced thermoplastic, SJOW, 18AWG/2C, 10 Ft. cord w/ Piggy-back plug, On point - 14.2, Off point - 5.9 P/N: PFTFS10D1810P1 MANUAL: No float WARRANTY: 3 year MODEL HP Hz Volts/Ph RPM FL AMPS Submersible Sump Pump 1-1/2 Discharge, 1/4 Spherical Solids Wide Angle Tethered Float & Manual Operation Cord Length PFSPPPP3328601T10 1/3 60 115/1 3450 7.6 10 ft 9 lbs PFSPPPP3328601M10 1/3 60 115/1 3450 7.6 10 ft 9 lbs Wt. HEAD in Ft 0 Ft 5 Ft 10 Ft 15 Ft 20 Ft 25 Ft FLOW Gallon/Minute 60 57 50 42 32 17 FLOW Gallon/Hour 3600 3400 3000 2500 1900 1000 Max Lift Max Pressure 28 Ft 12.4 psi PF TYPE U, SP, SW Motor Housing Impeller Type Suction Plate Type Motor HP 25, 33, 50, 75, 1 30 50 Voltage 1 or 2 Float Switch Type M, F, T Cord Length 10, 20 Power-Flo U = Utility SP = Sump Pump SW = Sewage Pump 25 = 1/4 HP 33 = 1/3 HP 50 = 1/2 HP 75 = 3/4 HP 1 = 1 HP Shut Off Head (ft) Max Flow (Gal) 1 = 115 V 2 = 230V M = Manual F = Fixed Vertical T = Tethered 10 Ft 20 Ft EXAMPLE: PFSPCPC3330501T10 - Power-Flo Pumps - Sump Pump - Cast Iron Motor Housing - Plastic Impeller - Cast Iron Suction Plate - 1/3HP - 30 Shut Off Head - 50GPM Max Flow - 115 Volt - Tethered Float - 10 Cord 5

PFSPPPP33 Series Performance & Dimensions Model: PFSPPPP3328601T10 6

PFSPCPC50 Series Features: General purpose pump for residential, light industrial and commercial sump applications Specifications DISCHARGE: 1-1/2 NPT Male, Vertical, 1-1/4 with Adapter LIQUID TEMPERATURE: 32-77 F MOTOR HOUSING: Cast Iron. IMPELLER: Corrosion-resistant, reinforced Thermoplastic PUMP BASE: Cast Iron. SHAFT: Stainless Steel HARDWARE: Stainless steel GASKET: Rubber SEAL: Single mechanical, rubber and stainless steel UPPER BEARING: Single row, ball, oil lubricated LOWER BEARING: Single row, ball, oil lubricated POWER CORD: SJTW, 18AWG/3C Cord, with plug. P/N: 10Ft. - PFL183062, 20Ft. - PFL181061 MOTOR: Energy efficient Permanent Split Capacitor (PSC), Water Cooled, Class B insulation, Continuous duty (water depth must be at least 6 to prevent motor from overheating), Auto reset thermal overload protector, Circuit requirments 15 AMPS. LEVEL CONTROL: Vertical, Mechatronic, Normally Open (N/O), Reinforced thermoplastic, SJTW 18AWG/3C, 10 Ft. OR 20 Ft. cord w/piggy-back plug, On point - 8.8, Off point - 4.4 P/N: 10Ft. - PFEVS10D1810P1, 20Ft. - PFEVS10D1820P1 WARRANTY: 3 year Submersible Sump Pump 1-1/2 Discharge, 1/4 Spherical Solids Vertical Float MODEL HP Hz Volts/Ph RPM FL AMPS Cord Length PFSPCPC5030721F10 1/2 60 115/1 3450 4.7 10 ft 21 lbs PFSPCPC5030721F20 1/2 60 115/1 3450 4.7 20 ft 21.2 lbs Wt. HEAD in Ft 0 Ft 5 Ft 10 Ft 15 Ft 20 Ft 25 Ft FLOW Gallon/Minute 72 65 58 52 42 28 FLOW Gallon/Hour 4300 3900 3500 3100 2500 1700 Max Lift Max Pressure 30 Ft 13.2 psi PF TYPE U, SP, SW Motor Housing Impeller Type Suction Plate Type Motor HP 25, 33, 50, 75, 1 30 50 Voltage 1 or 2 Float Switch Type M, F, T Cord Length 10, 20 Power-Flo U = Utility SP = Sump Pump SW = Sewage Pump 25 = 1/4 HP 33 = 1/3 HP 50 = 1/2 HP 75 = 3/4 HP 1 = 1 HP Shut Off Head (ft) Max Flow (Gal) 1 = 115 V 2 = 230V M = Manual F = Fixed Vertical T = Tethered 10 Ft 20 Ft EXAMPLE: PFSPCPC3330501T10 - Power-Flo Pumps - Sump Pump - Cast Iron Motor Housing - Plastic Impeller - Cast Iron Suction Plate - 1/3HP - 30 Shut Off Head - 50GPM Max Flow - 115 Volt - Tethered Float - 10 Cord 7

PFSPCPC50 Series Performance & Dimensions Model: PFSPCPC5030721F10 PFSPCPC5030721F20 8

PFSPCPC50 Series Features: General purpose pump for residential, light industrial and commercial sump applications Specifications DISCHARGE: 1-1/2 NPT Male, Vertical, 1-1/4 with Adapter LIQUID TEMPERATURE: 32-77 F MOTOR HOUSING: Cast Iron. IMPELLER: Corrosion-resistant, reinforced Thermoplastic PUMP BASE: Cast Iron. SHAFT: Stainless Steel HARDWARE: Stainless steel GASKET: Rubber SEAL: Single mechanical, rubber and stainless steel UPPER BEARING: Single row, ball, oil lubricated LOWER BEARING: Single row, ball, oil lubricated POWER CORD: SJTW, 18AWG/3C Cord, with plug. P/N: 10Ft. - PFL183062, 20Ft. - PFL181061 MOTOR: Energy efficient Permanent Split Capacitor (PSC), Water Cooled, Class B insulation, Continuous duty (water depth must be at least 6 to prevent motor from overheating), Auto reset thermal overload protector, Circuit requirments 15 AMPS. LEVEL CONTROL: Wide Angle Tethered, Mechanical, Normally Open (N/O), Reinforced thermoplastic, SJOW 18AWG/2C, 10 Ft. cord w/piggy-back plug, On point - 14.6, Off point - 6.3 P/N: 10Ft. - PFTFS10D180P1, 20 Ft. - PFTFS10D1820P1 MANUAL: No float WARRANTY: 3 year MODEL HP Hz Volts/Ph RPM FL AMPS Cord Length PFSPCPC5030721T10 1/2 60 115/1 3450 4.7 10 ft 21 lbs PFSPCPC5030721M10 1/2 60 115/1 3450 4.7 10 ft 21 lbs HEAD in Ft 0 Ft 5 Ft 10 Ft 15 Ft 20 Ft 25 Ft FLOW Gallon/Minute 72 65 58 52 42 28 FLOW Gallon/Hour 4300 3900 3500 3100 2500 1700 Submersible Sump Pump 1-1/2 Discharge, 1/4 Spherical Solids Wide Angle Tethered Float & Manual Operation Max Lift Wt. Max Pressure 30 Ft 13.2 psi PF TYPE U, SP, SW Motor Housing Impeller Type Suction Plate Type Motor HP 25, 33, 50, 75, 1 30 50 Voltage 1 or 2 Float Switch Type M, F, T Cord Length 10, 20 Power-Flo U = Utility SP = Sump Pump SW = Sewage Pump 25 = 1/4 HP 33 = 1/3 HP 50 = 1/2 HP 75 = 3/4 HP 1 = 1 HP Shut Off Head (ft) Max Flow (Gal) 1 = 115 V 2 = 230V M = Manual F = Fixed Vertical T = Tethered 10 Ft 20 Ft EXAMPLE: PFSPCPC3330501T10 - Power-Flo Pumps - Sump Pump - Cast Iron Motor Housing - Plastic Impeller - Cast Iron Suction Plate - 1/3HP - 30 Shut Off Head - 50GPM Max Flow - 115 Volt - Tethered Float - 10 Cord 9

PFSPCPC50 Series Performance & Dimensions Model: PFSPCPC5030721T10 10

PFSPPPP33 / PFSPCPC50 Series APPLICATION This submersible sump pump is designed for home sump applications. Use these pumps only for pumping water. Pre-Installation The pump is built with overload thermal protections and auto reset. The pump is equipped with a 3-prong grounding-type power cord and tethered or vertical float switch. This pump operates automatically. Ball bearings on motor shafts never need lubrication. TOOLS REQUIRED MATERIALS REQUIRED (NOT INCLUDED) 1-1/4 or 1-1/2 ABS or PVC Pipe 1-1/4 or 1-1/2 Check Valve 1-1/4 or 1-1/2 90 Elbow Minimum Sump basin: Tethered Switch - Min. 14 in. diameter, 18 in. depth Vertical Switch - Min. 10 in. diameter, 14 in. depth 11

PFSPPPP33 / PFSPCPC50 Series Installation INSTALLATION NOTE: Do not reduce size of discharge pipe or hose below 1-1/4 in. diameter. If discharge is too small, pump will overheat and fail prematurely. This pump is designed for use in a residential sump only. Only pump water with this pump. 1. Install the pump in sump pit with minimum diameter of 10 in. for models equipped with vertical switches and 14 in. for tethered float switch models. The sump depth should be 14 in. for vertically switched models and 18 in. for tethered models. Construct the sump pit of tile, concrete, steel or plastic. Check local codes for approved materials and for proper installation. 2. Install the pump in a pit so that the switch operating mechanism has maximum possible clearance. 3. The pump should not be installed on clay, earth or sand surfaces. Clean the sump pit of small stones and gravel which could clog the pump. Keep the pump inlet screen clear. NOTE: Do not use ordinary pipe joint compound on plastic pipe. Pipe joint compound can attack plastics. 4. Install discharge plumbing. Use rigid plastic pipe and wrap threads with PTFE pipe thread sealant tape. Screw pipe into the pump hand tight plus 1-1/2 turns. CAUTION: Risk of flooding. Can cause personal injury and/or property damage. If a flexible discharge hose is used, make sure the pump is secured in the sump to prevent movement. Failure to secure the pump may allow pump movement, switch interference and prevent the pump from starting or stopping. 5. To reduce motor noise and vibrations, a short length of rubber hose (1-7/8 in. I.D., e.g. radiator hose) can be connected into the discharge line near the pump using suitable clamps. 6. Install an in-line check valve or an in-pump check valve to prevent flow backwards through the pump when the pump shuts off. NOTE: If your check valve is not equipped with an air bleed hole to prevent air locking the pump, drill a 1/8 in. hole in the discharge pipe just above where the discharge pipe screws into the pump discharge. Be sure the hole is below the waterline and the check valve to prevent air locks. 7. Power Supply: Pump is designed for 115 V, 60 Hz, operation and requires a minimum 15 amp individual branch circuit. Plug the pump power cord plug into the piggyback switch plug outlet, and then plug the switch plug into a 115V GFCI power outlet for automatic operation. The pump will start operating if the float switch moves over the pump top. The water will be pumped out. When the water lowers to certain level, the float switch will turns off the pump. 12

PFSPPPP33 / PFSPCPC50 Series Installation & Operation Or plug the pump power cord plug into a 115V GFCI power outlet directly for manual operation. Pump will start operating immediately once it plug to the GFCI and drain water out, when the water moved out, you must unplug the pump immediately. Figure 1 shows a typical connection for pumps with the piggy-back plug, for manual and automatic operations. Automatic - Plug float cord into GFCI outlet, then plug pump cord into float cord. Manual - Plug pump cord directly into GFI outlet. WARNING: Risk of electric shock. Can shock, burn or kill. Pump should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or ground wire system. Do not cut off the round ground pin. Figure 1 - For 115 Volt 8. If the pump discharge line is exposed to outside subfreezing atmosphere, a portion of line exposed must be installed so any water remaining in the pipe will drain to the outfall by gravity. Failure to do this can cause water trapped in the discharge to freeze which could result in damage to the pump. 9. After the piping and check valve have been installed, the unit is ready for operation. 10. Check the pump operation by filling the sump with water and observing pump operation through one complete cycle. CAUTION Risk of flooding. Can cause personal injury and/or property damage. Failure to make this operational check may lead to improper operation, premature failure, and flooding. OPERATION WARNING: Risk of electric shock. Can shock, burn or kill. Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water. 1. The shaft seal depends on water for lubrication. Do not operate the pump unless it is submerged in water as the seal may be damaged if allowed to run dry. 2. The motor is equipped with an automatic reset thermal protector. If temperature in the motor should rise unduly, the switch will cut off all power before damage can be done to the motor. When the motor has cooled sufficiently, the switch will reset automatically and restart the motor. If the protector trips repeatedly, the pump should be removed and checked. Low voltage, long extension cords, clogged impeller, very low head or lift, or a plugged or frozen discharge pipe, etc., could cause the protector to trip. 3. The pump will not remove all water. If operating a pump manually, and suddenly no water comes out of the discharge hose, shut off the unit immediately. The water level is probably very low and the unit has broken prime. WARNING: Risk of electric shock. Can shock, burn or kill. Before attempting to check why the unit has stopped operating, disconnect power from the unit. 13

PFSPPPP33 / PFSPCPC50 Series Operation CAUTION: Do Not Change the preset tether length. CARE AND CLEANING CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use. Do - When the power is disconnected, inspect the pump suction screen and remove all debris, then plug the pump back into the grounded (GFCI) outlet. Do Not - Do not disassemble the motor housing. This motor has NO repairable internal parts, and disassembly may cause leakage or dangerous electrical wiring issues. Do not lift up the pump by the power cord. To clean a pump clogged with debris: Unplug the pump from electrical power. Unscrew the stainless screws, and remove the volute/bottom seal plate. Use a flathead screwdriver to hold the shaft, then turn the impeller counterclockwise to release the impeller. Remove debris from around the shaft and on/under the impeller. Reassemble the pump. Replacement Parts: LEVEL CONTROLS - 1/3 & 1/2Hp: Vertical 10Ft. Cord - P/N: PFEVS10D1810P1 Vertical 20Ft. Cord - P/N: PFEVS10D1820P1 Wide Angle 10Ft. Cord - P/N: PFTFS10D1810P1 Wide Angle 20Ft. Cord - P/N: PFTFS10D1820P1 CORD SET: 1/2Hp Only. Power Cord 10Ft. - P/N: PFL183062 Power Cord 20Ft. - P/N: PFL181061 14

PFSPPPP33 / PFSPCPC50 Series Troubleshooting Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs. Symptom Possible Cause(s) Corrective Action Pump does not start or run Pump operates but pumps little or no water Pump starts and stops too often Pump will not shut off 1. The fuse is blow. 2. The breaker is tripped. 3. The plug is disconnected. 4. The plug is corroded. 5. Thermal overload. 6. Clogged impeller. 7. Motor failed 8. Float failed 9. Water level too low 10. Tangled switch 1. The screen is blocked 2. Debris is caught in the impeller or discharge 3. Check valve stuck or installed backward 4. Anti-airlock hole blocked 4. Impeller loose on shaft 5. Impeller broken 1. Backflow of water from piping, check valve leaking 2. Float switch stuck 1. Defective float tangled 2. The float switch is faulty 3. Float obstruction 1. Replace the fuse 2. Reset the breaker 3. Secure the plug 4. Clean the plug prongs 5. Unplug for 30 minutes, then plug in 6. Remove the blockage 7. Replace pump 8. Replace switch 9. Pump will not turn on unless water level is over the pump cover and the float switch turns upside down 10. Reposition the pump and make sure switch moves freely 1. Clean the screen. 2. Remove debris 3. Inspect check valve and make sure it s properly installed 4. Remove the blockage 4. Reassemble impeller 5. Replace impeller 1. Install a check valve or replace check valve 2. Clean the float switch to make sure the floats moves up and down freely 1. Reposition the pump and make sure the switch moves freely 2. Replace the switch 3. Remove obstruction NOTE: Power-Flo Pumps & Systems assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Power-Flo Pumps & Systems or its authorized service centers, automatically voids warranty. 15

PFSPPPP33 / PFSPCPC50 Series 3 YEAR WARRANTY Manufacturer warrants, to the purchaser and subsequent owner during the warranty period, new pump product to be free from defects in material and workmanship under normal use and service, when properly used and maintained, for a period of 3 years from date of sale. The date of sale shall be determined by a dated sales receipt noting the model and serial number of the pump. The dated sales receipt must accompany the returned pump if the date of the return is more than 3 years from the date of manufacturer. Product will be repaired, replaced or remanufactured at Manufacturer s option. No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product failure, repair or replacement. This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior approval of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has not been installed, operated or maintained in accordance with Manufacturer s installation instructions; that has been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels or feminine sanitary products, etc. in all pumping applications. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products. Contact Manufacturer at: 1-877-24PUMPS or www.powerflopumps.com, Attention: Customer Service Department, to obtain any needed repair or replacement of part(s) or additional information pertaining to our warranty. MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY. Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or con sequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 16