ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

Similar documents
LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

LED DOWNLIGHTS. Prime K L LED Downlights with Separate LED Driver HIGH QUALITY COB TECHNOLOGY LED DOWNLIGHTS WITH SEPARATE LED DRIVER

LED CONVERTERS FOR LED MODULES 24 V

LED DOWNLIGHTS. Prime K L LED Downlights HIGH QUALITY COB TECHNOLOGY LED-DOWNLIGHTS

LED control gear Compact fixed output

LEDLINE ECX. LED Constant Current Drivers ELECTRONIC CONSTANT CURRENT DRIVERS LED CONSTANT CURRENT DRIVERS

LED BUILT-IN MODULES. LED Module Easy 28 Industrial and Hospitality Lighting EASY 28 3,500 LM TO 14,000 LM EASY 28 INDUSTRIAL AND HOSPITALITY LIGHTING

LED LINE SMD KIT GEN. 2

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LED Driver Compact fixed output

LED Driver Compact fixed output

THE PERFECT REPLACEMENT

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

LED MODULES. Comfort COB Residential, Retail and Industrial Lighting COMFORT COB 500 LM TO 11,000 LM

LED Driver Linear / area dimming

LED Driver Linear / area fixed output

Emergency lighting units EM powerled

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LE Fluorescent Ballast

PC T8 TEC, W PC TEC

Emergency lighting units EM powerled

LED MODULES. LUGA Shop Gen. 5 Retail and Industrial Lighting LUGA SHOP GEN LM TO 20,000 LM LUGA SHOP GEN. 5 RETAIL AND INDUSTRIAL LIGHTING

Input Current at 240V (A) Max. Input Power (W) Enclosure

EVOLVE 50. LEDSpots for Retail Lighting HID and Halogen Replacement NEW MODULAR LED ENGINES FOR MULTIPLE OPTICS CONFIGURATIONS

Model Number Structure

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled

ACTIVE PLUS. LEDSpots for Retail Lighting HID and Halogen Replacement NEW MODULAR LED ENGINES FOR MULTIPLE OPTICS CONFIGURATIONS

A LIFETIME OF LIGHT. Magnetic Ballasts (A2) plus Electronic Starter

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled

NEXT 111 / SHOPLINE 111

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

LED MODULES. LUGA Shop Gen. 6 Retail and Industrial Lighting LUGA SHOP GEN LM TO 15,000 LM LUGA SHOP GEN. 6 RETAIL AND INDUSTRIAL LIGHTING

SLA DC. LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

INSTALLATION INSTRUCTIONS

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Emergency lighting units EM converterled

Emergency lighting units EM converterled

LED BUILT-IN MODULES. LUGA Shop 2015 PCB LED Modules COB for Retail Environments PEARL WHITE LUGA SHOP 2015 PCB PEARL WHITE

Electronic ballasts for fluorescent lamps Professional electronic ballast

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

Max. Input Power (W) Inrush Current (A pk /µs)

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Emergency lighting units EM converterled

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Input Current at 240V (A) Max. Input Power (W) Dimming Method 1-10V Isolated. Enclosure

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

LED Office Solutions

Emergency lighting units EM powerled

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

ESC Aluminum Electrolytic Capacitors

LED BUILT-IN MODULES. LUGA C 2016 HiCRI COB modules for lumen packages from 1500 to 4500 lm. LUGA C 2016 HiCRI 1500 LM TO 4500 LM.

LEDSPOTS VOLTAGE-DRIVEN

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

DC/DC converters - MINI-PS DC/ 5-15DC/

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

multicond Power capacitors Data sheet: multicond

LED modules LED linear / area

Electronic Ignition Equipment

Emergency lighting units PC COMBO

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

Modular contactors and relays

QUINT-PS/24DC/24DC/20

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

QUINT-PS/24DC/48DC/ 5

Induction lamps and control gear

Emergency lighting units EM powerled

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Driver LC 17W mA flexc C EXC EXCITE series

LED light engine / OLED LED linear / area

LED SPOT. LEDSpot SmartLine SMD Furniture and Residential Lighting SMARTLINE SMD SMARTLINE SMD RECESSED MOUNTED LED SPOT

CertaDrive 60W 24VDC 220/240V

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

QUINT-PS/24DC/24DC/10

LED light engine / OLED LED compact. Umodule EOS P214-4 umodule EOS

Emergency lighting units EM powerled

FL ballasts Electronic fixed output

FL ballasts Electronic fixed output. PC TCL PRO, W PC PRO compact

Outdoor 200 W 2 Channel SL-L2701B0N1KR

Electronic Ignition Module

QUINT-PS/24DC/24DC/ 5/CO

Emergency lighting units EM powerled

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

Surface mounting, flush mounting, and DIN track mounting

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Transcription:

ROBUST LED DRIVERS EasyLine INDUSTRY 186452, 186453, 186454, 186455, 186456, 186477, 186510, 186617 Typical Applications Built-in in compact luminaires for Industrial lighting EasyLine Industry ENCAPSULATED CASING (IP67 OR IP65) VERY ROBUST CASING POWER FACTOR: > 0.90 OPTIMUM PRICE PERFORMANCE RATIO LONG SERVICE LIFETIME: UP TO 50,000 HRS. PRODUCT GARANTUEE: 5 YEARS

EasyLine LED Drivers Product features Robust casing shape Functions Moisture resistant with IP65/IP67 protection Electrical features Mains voltage: 220 240 V ±10% Mains frequency: 50 60 Hz Pre-assembled connection leads: primary: 3x2.08 mm², length: 320 mm secondary: 2x2.08 mm², length: 320 mm Power factor at full load: > 0.95 Secondary side switching of LED modules is not allowed. Safety features Protection against transient main peaks up to 1.5 kv (between L and N) (186617: up to 4 kv between L and N) Electronic short-circuit protection Overload protection Protection against "no load" operation Degree of protection: IP67 (186617: IP65) Protection class I Dimensions Ref. No. Casing Length [a] Width [b] Height [c] mm mm mm 186452 M56 185.5 49.4 40.6 186453 M56 185.5 49.4 40.6 186454 M58 205.6 49.4 40.6 186455 M58.1 206 68.6 37 186456 M58.1 206 68.6 37 186477 M58.1 206 68.6 37 186510 M65 216 68.6 46.3 186617 M58.1 206 68.6 37 Used standards EN 61347-1 EN 61347-2-13 EN 61547 EN 61000-3-2 EN 62384 EN 55015 Packaging units LED-Treiber_EasyLine_186452-186453-186454-186455-186456-186477-186510-186617_EN 2/6 06/2018 Ref. No. Packaging unit Pieces Boxes Weight per box per pallet g 186452 12 45 660 186453 12 45 660 186454 12 45 714 186455 12 45 840 186456 12 45 840 186510 12 45 1050 186477 12 45 840 186617 12 45 840 Product guarantee 5 years for operation at recommended operation temperature (see table for expected service life time on page 4) The conditions for the Product Guarantee of the Vossloh-Schwabe Group shall apply s published on our homepage (www.vossloh-schwabe.com). We will be happy to send you these conditions upon request. 2

Product drawings and photos M56 M56 186452, 186453 M58 M58 186454 M58.1 M58.1 186455, 186456, 186477, 186617 LED-Treiber_EasyLine_186452-186453-186454-186455-186456-186477-186510-186617_EN 3/6 06/2018 M65 M65 186510 3

Electrical characteristics Max. Type Ref. No. Voltage Mains Inrush Current Voltage THD Efficiency Ripple output 50 60 Hz current current output DC output at full load at full load 100 Hz W V ma A / µs ma (± 5%) DC (V) % (230 V) % (230 V) % 50 ECXe 700.156 186452 220 240 260 240 29.4 / 194 700 35 72 6 > 88 < 40 75 ECXe 1050.157 186453 220 240 380 350 36.7 / 213 1050 35 72 5 > 88 < 40 100 ECXe 1400.158 186454 220 240 520 470 50 / 105 1400 30 72 6 > 90 < 40 122 ECXe 1700.159 186455 220 240 640 580 108 / 78 1700 45 72 9 > 90 < 40 122 ECXe 1050.235 186617 220 240 630 570 45 / 280 1050 60 116 7 > 85 < 20 150 ECXe 2100.160 186456 220 240 790 720 52 / 470 2100 45 72 9 > 90 < 40 175 ECXe 2400.167 186510 220 240 920 820 93 / 203 2400 36 73 14 > 85 < 40 201 ECXe 2800.168 186477 220 240 1020 930 130 / 153 2800 45 72 9 > 85 < 40 Maximum ratings Exceeding the maximum ratings can lead to reduction of service life or destruction of the drivers. Ref. No. Ambient temperature Operation humidity Storage temperature Storage humidity Max. operation Degree of range range range range temperature at tc point protection C min. C max. % min. % max. C min. C max. % min. % max. C max. 186452 30 60 5 60 40 +85 5 95 75 IP67 186453 30 60 5 60 40 +85 5 95 80 IP67 186454 30 50 5 60 40 +85 5 95 80 IP67 186455 30 50 5 60 40 +85 5 95 75 IP67 186617 40 50 5 60 40 +85 5 95 75 IP65 186456 30 50 5 60 40 +85 5 95 75 IP67 186510 30 50 5 60 40 +85 5 95 80 IP67 186477 30 50 5 60 40 +85 5 95 80 IP67 LED-Treiber_EasyLine_186452-186453-186454-186455-186456-186477-186510-186617_EN 4/6 06/2018 Expected service life time at operation temperatures at tc point Operation Ref. No. current 186452, 186455, 186456, 186617 186453, 186454, 186510, 186477 all 65 C* 75 C 70 C* 80 C hrs. 50,000 30,000 50,000 30,000 * recommended operation temperature Product lables 4

Safety functions Transient mains peaks protection: Values are in compliance with EN 61547 (interference immunity). Surges between L/N: up to 1.5 kv (186617: up to 4 kv between L/N) Short-circuit protection: The control gear is protected against permanent short-circuit with automatic restart function. Overload protection: The control gear only works in range of rated output power and voltage problemfree (< 60 V DC). Please check before switch-on mains power supply that the selected LED load is suitable (see Electrical Characteristics on data sheet). No load operation: The control gear is protected against no load operation (open load). If any of the above mentioned safety functions will be triggered, disconnect the control gear from the power supply then find and eliminate the cause of the problem. LED-Treiber_EasyLine_186452-186453-186454-186455-186456-186477-186510-186617_EN 5/6 06/2018 5

Assembly and Safety Information Installation must be carried out under observation of the relevant regulations and standards. Installation must be carried out in a voltage-free state (i.e. disconnection from the mains). The following advices must be observed; non-observance can result in the destruction of the LED drivers, fire and/or other hazards. Mandatory regulations DIN VDE 0100 EN 60598-1 Secondary load: Parallel wiring: Wiring diagram: The sum of forward voltages of LED loads is within the tolerances which are mentioned in the Electrical Characteristics on the data sheet. Parallel connection of LED loads is not allowed. LED-Treiber_EasyLine_186452-186453-186454-186455-186456-186477-186510-186617_EN 6/6 06/2018 Mechanical mounting Mounting position: Built-in: Any position inside a luminaire is allowed Independent application: Drivers with preassembled connection leads are allowed to use for independent applications. Mounting location: LED drivers are designed for integration into luminaires or comparable devices. Independent LED drivers do not need to be integrated into a casing. Installation in outdoor luminaires: degree of protection for LED drivers IP67 (186617: IP65). Degree of protection: IP67 (186617: IP65) Clearance: Min. 0.10 m from walls. ceilings and insulation Surface: Solid and plane surface for optimum heat dissipation required. Heat transfer: If the driver is destined for installation in a luminaire. sufficient heat transfer must be ensured between the driver and the luminaire casing. LED drivers should be mounted with the greatest possible clearance to heat sources. During operation. the temperature measure at the driver's tc point must not exceed the specified maximum value. Fastening: Using M4 screws in the designated holes Electrical installation Connection leads: Pre-assembled, primary: 3x2.08 mm², length: 320 mm, secondary: 2x2.08 mm², length: 320 mm Wiring: The mains conductor within the luminaire must be kept short (to reduce the induction of interference). Mains and lamp conductors must be kept separate and if possible should not be laid in parallel to one another. Max. secondary side lead length: 0.8 m Polarity: Please ensure the correct polarity of the leads prior to commissioning. Reversed polarity can destroy the modules. Through-wiring: Is not allowed. Selection of automatic cut-outs for VS LED drivers Dimensioning automatic cut-outs High transient currents occur when an LED driver is switched on because the capacitors have to load. Ignition of LED modules occurs almost simultaneously. This also causes a simultaneous high demand for power. These high currents when the system is switched on put a strain on the automatic conductor cut-outs. which must be selected and dimensioned to suit. Release reaction The release reaction of the automatic conductor cut-outs comply with VDE 0641. part 11. for B. C characteristics. The values shown in the following tables are for guidance purposes only and are subject to system-dependent change. No. of LED drivers The maximum number of VS LED drivers applies to cases where the devices are switched on simultaneously. Specifications apply to single-pole fuses. The number of permissible drivers must be reduced by 20% for multi-pole fuses. The considered circuit impedance equals 400 mω (approx. 20 m [2.5 mm²] of conductor from the power supply to the distributor and a further 15 m to the luminaire). Type Ref. No. Automatic cut-out type and possible no. of VS drivers pcs. Automatic cut-out type B 10 A B 13 A B 16 A C 10 A C 13 A C 16 A ECXe 700.156 186452 10 13 17 17 23 28 ECXe 1050.157 186453 10 13 16 17 22 27 ECXe 1400.158 186454 17 22 27 17 22 27 ECXe 1700.159 186455 10 13 16 14 18 22 ECXe 2100.160 186456 3 4 5 5 6 8 ECXe 2400.167 186510 4 5 7 7 9 11 ECXe 2800.168 186477 4 5 7 7 9 11 ECXe 1050.235 186617 5 7 8 9 12 14 To limit capacitive inrush currents the current carrying capacity of each circuit breaker (fuse) can be increased by a factor of 2.5 with the help of our ESB-6K (Ref. No.: 149820) or ESB-16HS (Ref. No.: 149821) inrush current limiters. 6