Betriebsanleitung Operating Instructions. Oil Mist Filter

Similar documents
Operating Instructions

Operating Instructions

Betriebsanleitung Operating Instructions. Diaphragm Pump

Betriebsanleitung Operating Instructions

Betriebsanleitung Operating Instructions

Betriebsanleitung Operating Instructions. Rotary Vane Pump

Operating Instructions

Operating Instructions

Operating Instructions

Betriebsanleitung Operating Instructions. Piston Vacuum Pump

OPERATING INSTRUCTIONS UNO/DUO 35/65. Rotary Vane Pump. Translation of the original instructions PK 0168 BEN/P (1604)

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

OPERATING INSTRUCTIONS DUO 3 / DUO 3 M. Rotary Vane Pump. Translation of the original instructions PD 0060 BEN/H (1607)

Original Operating Instructions

DUO 3 / DUO 3 M / DUO 3 MC

Swing Piston Compressors and Vacuum Pumps

Operating Instructions

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List

A Issue F. Instruction Manual. Outlet Mist Filters and Catchpots. MF300AE outlet mist filter

Tips and tricks from the experts

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Netzteil Power Supply TPS TPS

Operating Instructions

A Issue F. Instruction Manual. EMF3, EMF10 and EMF20 EMF20 Oil Mist Filter

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Swing Piston Compressors and Vacuum Pumps

MVP DC / MVP DC

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Declaration of Conformity as per Directive 97/23/EC

Instruction in the text

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

LOG SPLITTER. Heavy Duty PTO Driven. Owners Illustrated Instruction Book & Parts List

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Diaphragm Vacuum Pumps and Compressors

Oil Rotary Vane Single-Stage Vacuum Pumps. Types

Swing Piston Compressors and Vacuum Pumps

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Operating Instruction Inline Detonation Flame Arrester

GRUNDFOS ALLDOS INSTRUCTIONS. DMB dosing pump. Installation and operating instructions (basic version)

Diaphragm-Gas Sampling Pumps

Operating Instructions Inline Detonation Flame Arrester and

Operating Instructions

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pump

HENALINE. A complete line of single-stage rotary vane pumps for low and medium vacuum applications. Safe. Reliable. Powerful.

Original Operating Instructions C-KLR

Installation, Operation, and Maintenance Manual

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

original operating manual Operating manual Translation of the Item-No.: ,

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Diaphragm Gas Sampling Pumps

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

Micro Diaphragm Gas Sampling Pumps

Diaphragm Vacuum Pumps and Compressors

DIAPHRAGM LIQUID PUMP NF 1.30

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

Operating Instructions

DIAPHRAGM LIQUID PUMP NF 2.35

Instruction Manual. Sewage lifting station compli 300

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

DIAPHRAGM VACUUM PUMP

Installation and Operation Manual

Operating manual Separator

Operating manual. Custom made gearboxes

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Control Gate Valve with stepper motor actuator

SOGEVAC SV40 B - SV65 B - SV100 B

Bowl feeder WV401-1 / Translation of operating and installation instructions

TRIVAC B. Rotary Vane Vacuum Pump S/D 1,6 B. Operating Instructions GA /8.02. Cat. No /26/ /26/27/31

Instruction Manual. EMF Clean Application Oil Drain Kits

HV Gate Valve with pneumatic actuator

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

have been approved by Leybold. TRIVAC B - DOT

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

Installation and Operating Manual

AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block

These installation and maintenance instructions must be read in full and completely understood before the installation!

Assembly and Maintenance Manual Type RSBW

Installation, Operating & Maintenance Instructions. Hot surfaces; do not touch!

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Assembly instructions

Installation, Operation, and Maintenance Manual

Oil-free piston compressors KK and piston vacuum pumps KV

Micro Diaphragm Gas Sampling Pumps

HST -LS Interlocking device (Translation of Original Manual)

Instruction Manual. E1M40, E1M80, E2M40 and E2M80 E2M40S and E2M80S Rotary Vacuum Pumps. Item Number

ON SAFEGUARD S ON SAFEGUARD M

Mod: KLD6-12/35XLAS-N

Mini UHV gate valve with manual actuator with pneumatic actuator

Angle seat valve with piston actuator VZXA-...-K

HiPace 80 for TCP 350, DN 63 ISO-K

Transcription:

Betriebsanleitung Operating Instructions Oil Mist Filter ONF 4-20 idealvac.com (505)872-0037 idealvac.com PK 0169 BE/E (0906)

Contents 1. Safety Instructions... 2 1.1. For Your Orientation... 2 2. Understanding the Oil Mist Filter.. 3 2.1. Application and Use... 3 2.2. Design... 3 3. Installation and Operation... 4 3.1. Fitting The ONF... 4 3.2. Fitting The Oil Return Line For The DUO 10 (PK 196 173-T)... 4 5. Technical Data... 5 6. Spare Parts... 5 7. Accessories... 5 Declaration Of Contamination... 6 4. Maintenance... 5 4.1. Draining the Operating Fluid... 5 4.2. Changing the Filter Cartridge... 5 1. Safety Instructions Read and follow all instructions in this manual. Inform yourself regarding: Hazards which can be caused by the pump; Hazards which can be caused by your system. Observe the safety and accident prevention regulations. Regularly check that all accident prevention measures are being complied with. Do not carry out any unauthorised conversions on or alterations to the unit. When returning units, take note of shipping instructions in the Section Service. Pictogram definitions WARNING WARNING Danger of personal injury. Danger of burns from touching hot parts. 1.1. For Your Orientation Instructions in the text Operating instructions: Here you have to do something! Danger of damage to the unit or to the system. Symbols used The following symbols are used throughout in the illustrations: Vacuum flange Exhaust flange Position numbers Identical components and accessories parts have the same position numbers in all illustrations. Attention to particularly important information PLEASE NOTE on the product, handling the product, or to a part of the documentation. particular Modifications reserved. Please note: Current operating instructions are also available via www.pfeiffer-vacuum.net. 2

2. Understanding the Oil Mist Filter 2.1. Application and Use The oil mist filter is fitted to the exhaust port of the rotary vane vacuum pump. It reduces air pollution by operating fluid mist expelled in greater or smaller quantities (depending on the working pressure) from the pump. The Oil Mist Filter ONF 4-20 is suitable for rotary vane vacuum pumps with smaller gas throughputs, up to a volume flow rate of 20 m 3 /h. The ONF 4-20 is specially suitable for Pfeiffer Vacuum rotary vane vacuum pumps DUO 5/10/20. The filter is not suitable where the pumping of corrosive gases and vapours or those gases which tend to polymerise or which can cause resinification of the oil mist filter is involved. 2.2. Design A micro-fibre cylindrical filter cartridge is encased in plexiglass. A pressure plate is pressed down onto the filter element by a spring. The arrangement of pressure plate and spring is such that it works as an over-pressure valve and opens when the filter element becomes dirty. Separated operating fluid can be observed through the plexiglass and drained off via the drain screw. Fig. 2 4 Spring 6 Drain screw 7 Screw 8 Nut 9 O-ring 10 O-ring 11 Two part casing 12 Filter cartridge 18 Pressure plate X Pumping connection Exhaust connection 11 4 18 12 7 8 9 10 6 X 3

3. Installation and Operation 3.1. Fitting The ONF ISO small flanges or ISO clamping flanges are provided on the input and output ports for connecting the oil mist filter. The flange marked with an X in Fig. 2 should always be connected facing the pump. Avoid stress from the connecting lines acting on the pump. As a result of differences in temperature between the pump and the oil mist filter or where the application involves the pumping of condensable vapours, condensed vapour (e.g. water) is deposited in the ONF. Condensate returned via the oil return line causes a detrioration in the quality of the pump operating fluid. Any operating fluid which has been enriched with condensate should be drained off in accordance with the instructions in Section 3.1. drain off or return separated operating fluid if the oil in the oil mist filter becomes foamy because of a high gas throughput. 3.2. Fitting The Oil Return Line (PK 196 173 -T) Fitting Drain off any operating fluid from the ONF by turning out the operating fluid drain screw 6. Unscrew operating fluid drain screw 6 on the ONF, drain off any operating fluid and screw in hose nipple 220 in place of the drain screw 6; take care with the O-ring 137. Dismantle gas ballast valve 42 from the pump. Re-fit the gas ballast valve with intermediate flange 45 and screw tight with longer screws; take care with the two O- rings 148. Screw hose nipple 220 into intermediate flange 45; take care with O-ring 138. Fit oil return hose 222 both sides on the hose nipples and tighten with hose clips 223. The function of the oil return system to the vacuum pump is only safeguarded providing the rotary vane pump working pressure is < 100 mbar. Long evacuation phases with high intake pressures should also follow longer operating phases with lower working pressures (< 100 mbar). If gases are being pumped which should not be allowed to escape into the atmosphere an exhaust line must be fitted. The exhaust line should be laid so that no excess pressure can build up in it. ONF with the oil return system (PK 196 173-T) 11 Casing, zweiteilig 42 Gas ballast valve 45 Intermediate flange 137 O-ring 138 O-ring 148 O-ring 220 Hose nipple with nozzle 221 Hose nipple 222 Oil return hose 223 Hose clip 11 137 221 42 148 45 223 222 223 220 138 148 4

4. Maintenance 4.1. Draining the Operating Fluid WARNING Toxic gases and vapours can escape from the pump fluid which may also become enriched with substances harmful to health (radioactive, chemical etc.) during the pumping of certain media. Operating fluid which has been enriched with toxic or aggressive substances must be treated carefully. Compliance with all relevant regulations is essential. If the operating fluid rises too high in the oil mist filter (filter cartridge half-full) it must be drained off. Unscrew drain screw 15. Drain operating fluid. If the operating fluid is uncontaminated it can PLEASE NOTE re-used in the vacuum pump. be 4.2. Changing the Filter Cartridge It is necessary to change the filter cartridge if oil mist forms on the exhaust flange, or if the exhaust pressure increases to the point where the baffle, which operates as an over-pressure valve, opens. Dismantling Before proceeding with dismantling the oil mist filter, the connected vacuum pump must be disconnected. Unscrew screws 7; take care to the pre-stressing of the compressing spring. Remove casing upper part from lower part, take care with seal 9. Remove filter cartridge 12 from the casing. Once the cartridge has been replaced, assembly is in reverse order. 5. Technical Data Technical Data Capacity l 0,04 (filter cartridge half-full) Separation level % 99,98 Permissible working pressure bar 1,5 Weight kg 0,2 6. Spare Parts Pos. Description Peace Dimensions Number Comments Ordering quantity Maintenance kit 1 PK E17 001 -T 4 Spring 1 P 0920 554 E 9 O-ring 1 66,27 x 3,53 P 4070 959 PV 10 O-ring 1 4,48 x 1,78 P 4070 047 PV 12 Filter cartridge 1 PK 005 627 18 Pressure plate 1 P 0920 553 E 137 O-ring 1 5 x 1,5 P 4070 065 PV 138 O-ring 1 6 x 2,2 P 4070 088 PV 148 O-ring 1 27 x 2,5 P 4070 465 PV 220 Hose nipple with nozzle 1 PK 194 235 221 Hose nipple 1 PK 194 317 222 Oil return hose 1 0,5 m, 4/6 P 2354 052 MV 223 Hose clip 2 SM5, B6 - W4 P 4165 500 AY 7. Accessories Description Type Number Ordering quantity Retrofit kit oil return unit ONF 4-20 PK 196 173 -T 5

Declaration on contamination of vacuum units and components Repairs and/or maintanance will be carried out on vacuum units and components only if a fully filled out, correct contamination declaration is provided. If this is not the case, the corresponding repairs will be delayed or omitted. A separate declaration must be submitted for each device and each component. This declaration can only be completed and signed by authorised and qualified staff: 1. Description of component - Equipment type/model: - Code No.: - Serial No.: - Invoice No.: - Delivery Date: 2. Reason for return 3. Equipment condition - Has the equipment been used? yes no - What type of pump oil was used? 4. Process related contamination of equipment - toxic yes no - corrosive yes no - microbiological hazard*) yes no - explosive*) yes no - radioactive*) yes no - other harmful substances yes no *)We will not accept delivery of any equipment that has been radioactively or microbiologically contaminated without written evidence of decontamination! 5. Please list all substances, gases and by-products which may have come into contact with the equipment: Tradename Chemical name Danger class Precautions associated Action if spillage or human Product name (or Symbol) with substance contact Manufacturer 1. 2. 3. - Has the vacuum device/component been cleaned? yes no Detergents: Cleaning method: - Is the equipment free from potentially harmful substances? yes no 6. Legally binding declaration We hereby guarantee that the details in this declaration are correct and complete. I, the undersigned, am able to provide a true assessment. We are aware of our liability toward the contractor for damage resulting from incomplete or inaccurate details; we undertake to indemnify the contractor against third-party claims. We are also aware, irrespective of this declaration, of our liability toward third parties, which include in particular those employees of the contractor who are entrusted with handling/repairing the product. Name of Organisation: Address: Post code: Tel.: Fax: Email: Name: Job title: Date: Company stamp: Legally binding signature: 6

7

Vacuum is nothing, but everything to us! Turbopumps Rotary vane pumps Roots pumps Dry compressing pumps Leak detectors Valves Components and feedthroughs Vacuum measurement Gas analysis System engineering Service Pfeiffer Vacuum Technology AG Headquarters/Germany Tel. +49-(0) 64 41-8 02-0 Fax +49-(0) 64 41-8 02-2 02 info@pfeiffer-vacuum.de www.pfeiffer-vacuum.net