Dead Tank Circuit Breakers

Similar documents
Live Tank Circuit Breakers kV Reliability through Technical Excellence

Gas Insulated Switchgear

High Voltage Disconnect Switches

Independent Testing Laboratory for High Voltage Equipment

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Vacuum Circuit Breaker VS1

Dead Tank Circuit Breakers

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Medium voltage vacuum circuit breaker. E-VAC series

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

3AP1 DTC for 145 and 245 kv

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

B kv T&D GAS INSULATED SWITCHGEAR

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Gas Insulated Switchgear

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Powering business worldwide

XIRIA Green, Smart, Compact solution

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Exceeding the standards with MNS

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Outdoor vacuum breaker for railway applications - FSK II

EMPAC Metal enclosed capacitor bank for wind applications

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Product brochure. Gas-insulated switchgear ELK-4, 800 kv Pioneering technology for extra-high voltage applications

B kv Gas-insulated Substations

Gas Insulated Metal-clad Switchgear, HMGS!

Raising the bar. UHV switchgear and components

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Distribution transformers Efficiency over life-cycle

Solid Dielectric, Single Phase Reclosers

Publication No.: PSG

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Solid Dielectric, Single Phase Recloser

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Microgrid solutions Delivering resilient power anywhere at any time

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

This small footprint makes a BIG impact

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

3TM Vacuum Contactors

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Cobra-S. Catalog Cobra-S

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

HIGH POWER RECTIFIER SYSTEMS

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation

Power Voltage Transformers for Air Insulated Substations

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

Air-insulated switchgear UniGear type ZS1

Enabling the power of wind. Competence and expertise for wind power customers

Low Voltage Main Distribution Board

Product Brochure. Gas-insulated Switchgear ELK-14 The modular system for GIS, 245 kv

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

36kV Gas Insulated Medium Voltage Switchgear

Compact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS)

Accelerate your grid modernization with smart RMUs. Ring main units with smart grid-ready feeder automation

Power Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Metal enclosed capacitor banks: ABBACUS family

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

UniSec Maintenance solutions

PASS M00. Multifunctional modules for high voltage substations kv; A;... 31,5 ka

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

DC Substation Solutions For Metal Processing Applications

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Gas Insulated Switchgear

High Voltage Technology & Testing

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

Transmission Switching

Substation Concepts for the Future

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Transcription:

g Dead Tank Circuit Breakers 72.5 800kV Advanced Technology in a Compact, Reliable Design with Primary Plus TM Pre-engineered solution set that digitizes XD GE primary equipment and provides factory installed and configured protection, monitoring, diagnostics and communications. GE Digital Energy

363kV Dead Tank SF 6 Circuit Breaker 800kV Dead Tank SF 6 Circuit Breaker Robust, High Quality and Reliable Breaker Technology For over a century, utilities around the world have relied on GE products and services to increase power system reliability and improve grid resiliency and responsiveness. As a global leader in grid infrastructure products and services, GE supports a broad set of utility applications ranging from transmission and substation automation to distribution networks and smart metering, enabling greater safety, connectivity and increased security. Through an alliance with XD Electric, GE has extended its portfolio to include high and ultra high-voltage power equipment supporting the highest transmission voltage levels in the world. XD Electric is one of China s largest primary equipment manufacturers dedicated to the research, application and development of high and ultra high-voltage power transmission equipment. XD Electric has a broad range of products to transform and direct the flow of power for industrial, commercial and residential users. The XD GE alliance provides end-to-end transmission solutions to meet the growing demand for electricity globally. The combined portfolios of GE and XD provide a comprehensive range of technology solutions for customers in the utility sector and energy intensive industries. The XD GE breaker offerings are robust in design and are based on proven technology, yielding high quality products suitable for an extensive range of applications. XD GE s breakers are compact in design and construction with advanced puffer type arc extinguishing technology which significantly reduces product size and improves reliability. Designed with a modular spring operated mechanism and an integrated hydromechanical operating mechanism, these circuit breakers improve product reliability, reduce costs, and minimize maintenance requirements. 2 GEDigitalEnergy.com

Dead Tank Circuit Breakers 72.5 800kV Key Features & Benefits Reduced Footprint Current transformers equipped in the bushing insulators allow for reduced space and foundations required for installation. Compact Design and Construction Advanced arc extinguishing technology significantly reduces product size and improves reliability. Excellent Seismic Performance and Pollution-Resistant Capability The dead tank circuit breaker is well-suited for areas with frequent earthquakes, high elevation or severe pollution. Maintenance Free Design Modular spring operated mechanism and integrated hydromechanical operating mechanism improve product reliability, reduce costs, and minimize maintenance requirements. Primary Plus XD GE offers Primary Plus for all its critical power delivery equipment. Primary Plus is a pre-engineered solution set that provides utilities and large industrial facilities with a means to reduce the time and labor associated with substation construction, expansion, and maintenance, while utilizing technologies and methodologies familiar to existing engineering resources. XD GE s factory installed and configured solutions include: Digitized primary equipment by replacing labor-intensive, individually terminated copper wires with standardized physical interfaces and open communications protocols (IEC 61850) Electrical protection systems optimized for each primary asset and application to monitor and react to fault conditions 72.5kV Dead Tank SF6 Circuit Breaker Highly secure and ruggedized communication network equipment including industrial strength wireless, fiber optic multiplexers, and Ethernet switches for an advanced and reliable communications infrastructure 3

72.5kV SF 6 Insulated Breaker 126/145/252kV SF 6 Insulated Breaker The LW24-72.5 is an outdoor dead tank SF 6 circuit breaker with puffer type interrupter technology and a spring operating mechanism. Puffer type interrupting technology has been applied for many years, is well proven and is accepted as the industry standard. Performance & reliability is enhanced with this technology. The operating mechanism used in this breaker, the CT20-II, is a spring driven mechanism. The advantages of this spring operated mechanism include improved stability and reliability, increased stability with ambient temperature changes, and minimal to zero maintenance given the lack of oil or gas component. The LW24-72.5 product has received independent KEMA certification. To achieve certification, the product passed the back-to-back switching test as well as the shunt reactor switching test. Type LW24-126/145/252/T outdoor dead tank SF 6 circuit breaker product line incorporates world class advanced technology at these kv ratings. Single pressure puffer type interrupting technology is employed. This industry standard technology simplifies the design and assembly, improves reliability and provides superior arc interruption capabilities for successful interruption of all industry standards interruption requirements. The operating mechanism is a spring design, which makes the product simple in construction and light in weight with higher reliability and less noise in operation. This family of dead tank circuit breakers will have independent certifications from XIHARI, MHI, or KEMA depending on the rating class and design. This dead-tank breaker design is the most widely produced by XD GE with over 2,000 units shipped and in service over the last few years. Normal Service Conditions 2.1. Altitude 3000m 2.2. Humidity monthly 90% 2.3. Max. wind velocity 35m/s 2.4. Pollution class: IV class 2.5. Typical ambient temperature: -35 C to +40 C 2.6. Max. temperature difference daily: 25 C 2.7. Seismic withstand capability 0.5g 2.8. Ice coating: 10mm 2.9. Max. radiance from sun: 1000 W/m2 Normal Service Conditions 2.1. Altitude: 1000m (not more than 3000m in special condition) 2.2. Humidity monthly 90% 2.3. Max. wind velocity 35m/s 2.4. Pollution class: III, IV class 2.5. Typical ambient temperature: -35 C to +40 C 2.6. Max. temperature difference daily: 25 C 2.7. Seismic withstand capability 0.5g 2.8. Ice coating: 10mm 2.9. Max. radiance from sun: 1000 W/m2 72.5kV Dead Tank Circuit Breaker 126kV Dead Tank Circuit Breaker 4 GEDigitalEnergy.com

363/550/800kV SF 6 Insulated Breaker The LW13A/23-363, LW13A-550, and LW13-800 family of products represent the technology platform for the highest kv rated XD GE dead tank breakers. Single interrupting units per pole are utilized on breaker products from 363kV to 550kV without parallel capacitors and pre-insertion resistors. In addition, double interrupting unit designs are used for products from 363kV up to 800kV. Parallel capacitors and pre-insertion resistors are incorporated when double interrupting units per pole are used. Breakers from 363kV to 800kV can carry continuous current up to 5000A and have interrupting capability for short circuit at either 50kV or 63kA, per customer specification. Breakers above 363kV are equipped with the CYA8 hydromechanical mechanism. The fully integrated hydro-mechanical operating mechanisms are maintenance-free designs with long-term stability and reliability. 363kV - 800kV series dead tank breakers are tested and certified per IEC standards by XIHARI, the national HV lab in China. Normal Service Conditions 2.1. Altitude: 1000m (not more than 3000m in special condition) 2.2. Humidity monthly 90% 2.3. Max. wind velocity 35m/s 2.4. Pollution class: III, IV class 2.5. Typical ambient temperature: -35 C to +40 C 2.6. Max. temperature difference daily: 25 C 2.7. Seismic withstand capability 0.5g 2.8. Ice coating: 10mm 2.9. Max. radiance from sun: 1000 W/m2 363kV Dead Tank SF 6 Circuit Breaker 50kA 550kV Dead Tank SF 6 Circuit Breaker 800kV Dead Tank Circuit Breaker 550kV Dead Tank SF 6 Circuit Breaker GEDigitalEnergy.com 5

Technology 1. Interrupter The figure below shows the principle construction of the interrupter. The pressure of the gas in the puffer cylinder goes up when the gas is compressed by opening movement of the puffer cylinder. This pressurized and compressed gas goes to the arc between the stationary contact and moving contact. The nozzle concentrates the gas flow to the arc for efficient cooling. Inner Construction of Interrupter Fixed main contact Fixed arcing contact Moving main contact Piston Cam Cam Trip spring Trip spring Arc Ratchet Ratchet Nozzle Moving arcing contact Puffer cylinder Fixed Closing Closing finger spring spring Lever Lever Ratchet Ratchet wheel wheel 2. Spring Operating Mechanism The design of the spring operated mechanism provides the high performance required for reliable operation. The lever engaged with the locking device, which is released when the trip coil is energized, is rotated counterclockwise by the trip spring (Fig.1). The cam and the ratchet wheel engaged with the locking device, which is released when the closing coil is energized, are rotated counterclockwise by Closing-holding latch latch Trip-holding Trip-holding Closing Closing trigger trigger the latch closing latch spring. The lever is rotated clockwise, compressing the trip spring by torque from the cam (Fig.2). Closing Closing coil coil As soon as the closing sequence is completed, the closing spring is charged interrupter interrupter open open coil coil by the ratchet linked to the motor (Fig.3). Trip trigger Trip trigger Fig1. Fig1. Closed Closed position position (closing (closing spring spring charged) charged) Cam Trip spring Ratchet Lever Closing spring Ratchet wheel Closing-holding latch Trip-holding latch Closing trigger Closing coil interrupter Trip trigger open coil Fig1. Closed position (closing spring charged) Fig2. Fig2. Open Open position position (closing (closing spring spring charged) charged) Fig3. Fig3. Closed Closed position position (closing (closing spring spring discharged) 6 GEDigitalEnergy.com

3. Hydromechanical Operating Mechanism for Circuit Breakers The hydromechanical mechanism is built with its functional parts linked by integrated modules. To keep the operation as relaible as possible, O -rings are used at sealing points, disc-type springs are used to store energy, and two sets of respectively independent opening control valves are incorporated into the design. This mechanism can be operated either in single phase or in three phase electrically, and can be gang-operated in three phase mechanically. Hydro-mechanical mechanism a. Uncharged, open position Hydro-mechanical mechanism b. Charged, open position c. Charged, closed position a. Uncharged, open position b. Charged, open position 1. Low pressure oil tank 2. Oil lever indicator 3. Operating piston rod 4. High pressure oil tank 1. Low pressure oil tank 5. Piston for charge 6. Support ring 2. Oil lever indicator 7. Disk spring 3. Operating piston rod 8. Auxiliary switch 4. High pressure oil tank 9. Oil-filling hole 5. Piston for charge 10. Throttle of close 6. Support ring 11. Electro-magnetic valve for close 7. Disk spring 12. Electro-magentic valve for open 8. Auxiliary switch 13. Throttle of open 9. Oil-filling hole 14. Oil drainage valve 10. Throttle of close 15. Energy-store motor 11. Electro-magnetic valve for close 16. Oil pump 12. Electro-magentic valve for open 13. Throttle of open 14. Oil drainage valve 15. Energy-store motor 16. Oil pump 17. Pressure release valve 18. Spring position switch c. Charged, closed position 17. Pressure release valve 18. Spring position switch 1. Low pressure oil tank 2. Oil lever indicator a. Uncharged, 3. Operating piston rod open position 4. High pressure oil tank 5. Piston for charge 6. Support ring 7. Disk spring 8. Auxiliary switch High pressure oil 9. Oil-filling hole 10. Throttle of close 11. Electro-magnetic valve for close 12. Electro-magentic valve for open 13. Throttle of open 14. Oil drainage valve 15. Energy-store motor 16. Oil pump 17. Pressure release valve 18. Spring position switch b. Charged, open position High pressure oil Low pressure oil c. Charged, closed position Low pressure oil 550kV Dead Tank SF 6 Circuit Breaker GEDigitalEnergy.com 7

2.5 Dead 800kV Tank DeadTank Circuit Breakers Circuit Breakers 72.5 800kV Innovative Facilities and Rigorous Quality Processes XD GE s technology portfolio is built in state-of-the-art manufacturing and testing facilities with robust quality processes which provide customers with products that meet the critical and demanding reliability and environmental challenges of transmission applications. Manufacturing Excellence XD GE designs a broad range of switchgear in five specialized production facilities including machining, surface treatment, insulating, housing and casting. Additionally, there are two specialized facilities that produce both the spring and hydromechanical operating mechanisms. Final production is completed in three workshop assembly lines that total more than 50,000 square meters. Components such as aluminum enclosures, cast resin insulators, current and voltage transformers, and operating mechanisms are manufactured by XD GE through a completely integrated manufacturing model. Advanced Test Facilities XIHARI, the Xi an High Voltage Apparatus Research Institute, is an integral part of the XD GE alliance. XIHARI has extensive testing capabilities at its facility sites, which include a: High Power Laboratory, High Voltage Laboratory, Artificial Climate Laboratory, EMC Laboratory, and an Operational Test Circuit for HVDC Thyristor Valves. The testing hall meets all of the requirements of ISO/IEC 17025 and houses some of the largest test equipment in the world, providing the capacity to test primary equipment as large as 1,100kV AC. The High Voltage Apparatus Laboratory in XIHARI is a government authorized national high-voltage apparatus quality supervision and inspection test center. It is an independent third-party laboratory for type tests, routine tests, performance tests and certificate tests for high-voltage apparatus. The testing facilities at XIHARI also include an extension environmental laboratory. Testing capabilities here include high altitude testing, high humidity testing, and temperature testing from -70 C up to +150 C. The switchgear facilities are ISO 9001 certified, ISO 14001 certified for environmental management systems, as well as OSHA 18001 certified for health and safety management systems. Exceptional Quality A focus on quality is an ongoing strategic initiative for XD GE and that is evident throughout the manufacturing environment. The quality process begins with an incoming inspection of all materials to ensure the best possible inputs before manufacturing begins. Throughout the production and assembly process, there are multiple checkpoints in the documented test plan, including both visual and stop flow inspections. The production facilities follow strict non-conforming procedures to identify, control and avoid the use and delivery of non-conforming products. Each production facility has developed strict environmental standards, including controls of cleanliness, temperature and humidity, and has controls in place to monitor and manage to the established standards. In addition, XD GE has a dedicated measuring and inspection department with certified, full-time inspectors in each of its manufacturing sites. The measuring and inspection department provides a secondary cross-inspection for all work in process, as well as finished products, ensuring a high level of quality is achieved throughout the manufacturing process. First Pass Yield and Cost of Quality data is maintained and analyzed, per product family, in order to drive continual product and process improvements and higher product reliability. From raw materials acquisition and inspection to finished product, XD GE s breakers are designed to meet rigid quality processes so the installed product provides the highest level of reliability. 8 GEDigitalEnergy.com

Support and Service Global Project Engineering Services XD GE is dedicated to helping its customers reach their system objectives and provides a suite of professional services to assist the successful deployment and maintainance of XD GE products and solutions globally. From design to implementation to post-sales support, a team of technical and business experts are available to help customers effectively use the capabilities and product domain knowledge that are available from XD GE. This support infrastructure covers the entire life cycle of the product. From the coordination of transportation logistics to the completion of site acceptance testing and warranty service, the highly qualified XD GE team is available throughout the implementation. To ensure a high quality of service to meet the needs of each unique application, XD GE has a global field service team of highly experienced and dedicated individuals. Coupled with a vast network of high voltage power equipment domain experts, XD GE is able to support a broad range of applications in various environments. Finally, XD GE offers a 24x7 global support service to address and direct any customer application and field questions. Specialized Installation and Commissioning Logistics including coordination of ocean and inland transportation Installation services include receiving, rigging, unloading and labor (mechanical and electrical) Test commissioning Site acceptance testing Post-Sales and Installation Support 24x7 global customer service Emergency response hotline Several customer support access points available to ensure timely support (telephone, e-mail, fax, or web) Global spare parts reserve A global network of maintenance and repair facilities 4800kV/720 kj Impulse Voltage Generator & ±2000kV 30mA DC Voltage Generator GEDigitalEnergy.com 9

Primary Plus Pre-Engineered Secondary Equipment Primary Plus, XD GE s supplemental offering to its primary equipment, is a pre-engineered, factory installed solution set that allows utilities to reduce the time and labor associated with substation construction and commissioning. Primary Plus uses technologies and methodologies familiar to existing resources and skill sets. Digitized primary equipment for replacing labor-intensive, individually terminated copper wires Electrical protection solutions to monitor and react to fault conditions Secure and ruggedized communications infrastructure devices including wireless radios, fiber optic multiplexers and Ethernet switches Digitized Substation Multilin TM HardFiber System Using the Multilin HardFiber system, XD GE can deliver primary equipment with digital communications. The Multilin HardFiber system digitizes analog signals from primary assets utilizing IEC 61850 communications, reducing total life costs of protection and control through labor and resource optimization. This factory-installed solution reduces the amount of labor-intensive, individually terminated copper wire connections with pre-terminated copper and fiber optic cables with standard physical interfaces and open digital communications. Key Benefits Saves up to 50% of Protection & Control labor costs Eliminates the majority of copper wiring to better utilize resources for the design, building, commissioning, and maintenance of power system protection and control Robust and simple architecture for deploying IEC 61850 process bus Improves employee safety by leaving potentially dangerous high-energy signals in the switchyard Reduces the chances for operational mistakes made during isolation and restoration after routine maintenance Built as an extension of the Multilin Universal Relay (UR) family of products, suitable for a wide array of protection applications Rugged, hardened, and secure switchyard interface enabling NERC/CIP compliance Electrical Protection & Control Advanced Relays for Primary Substation Equipment Primary Plus utilizes the Multilin C60 Breaker Protection system or Multilin F60 Feeder Protection system to provide primary protection of critical substation equipment. Multilin relays are substation hardened devices that provide comprehensive protection, control, automation, and monitoring of high voltage substation circuit breakers. With fast, deterministic execution of programmable automation logic, extensive I/O options, and integrated high-speed peer-to-peer communications, Multilin protection devices can receive and execute commands and at a fraction of the cost when compared to a traditional hard-wired configuration. Key Benefits Advanced circuit breaker monitoring and control in a single platform Complete IEC 61850 Process Bus solution providing resource optimization and minimizing total protection & control lifecycle costs Modular hardware architecture allow for device configuration flexibility, meeting the needs of most circuit breaker applications Advanced fault and disturbance recording, including internal device health monitoring, eliminating the need for external devices and maximizing asset life Robust network security enabling critical infrastructure Protection and NERC/CIP compliance Advanced automation capabilities for customized protection and control systems Simplified system integration and access to information through the use of multiple communication options and protocols, including native support for IEC 61850 10 GEDigitalEnergy.com

Dimensions and Foundation 72.5kV SF 6 Breaker LW24-72.5 LW24-72.5 2530 2320 1160 10 2115 10 30 30 1360 Grounding Terminal 885 3650 2363 2806 2 4-M10 981 32 56 120 920 120 1280 300 32 56 M20 85 1280 500 392 500 150 920 280 940 400 80 R616 All measurements are in millimeters (mm) GEDigitalEnergy.com 11

280 250 Dead Tank Circuit Breakers 72.5 800kV 126-145kV SF 6 Breaker LW24-126/LW24-145 251 2030 1560 1510 3200 1510 C N12 2-M10 800 40 3820 40 22x2.4 100 370 4-ф14 225 45 102 530 45 30 1000 1530 1000 1750 1070 1670 2300 3820 3900 2*4-M10 175 1000 180 1300 175 610 34 50 6-ø12 180 120x200 1500 1000 500 500 38 120 120 120 200 610 100 250 100 38 220 650 650 100 1300 1800 85 630 100 250 200 R750 R750 (865) 1205 2070 370 12 GEDigitalEnergy.com

252kV SF 6 Breaker LW24-252 outline and foundation drawing LW24-252 3000-4000 3000-4000 (2860) P1 P2 (2511) 1220 Phase A P1 Phase B P1 Phase C P1 t22 Aluminum Alloy Plate A-A 2860 (5165) 1320 591 9-φ18 45 45 45 45 45 145 A A R9.5 800 800 Terminal Pad Grounding Block 100 800 100 100 P2 P2 P2 924 70 A-A Cement Foundation E 320 E Anchor Bolt M30*800 Grounding Position (2 places) E 1220 220 245 A E 1380 1380 245 E 320 C E A 300 145 500 373 C All measurements are in millimeters (mm) GEDigitalEnergy.com 13

363kV SF 6 Breaker LW23-363 LW23-363/Y 363kV DTB with single-breaker 4000-5000 4000-5000 873 510 700 920 (3463) 1500 6534 (1438) 14 GEDigitalEnergy.com

363kV SF 6 Breaker LW13-363/Y Outline Drawing of 363kV DTB with double-breakers LW13A-363 5000 5000 845 800 1100 2200 2180 1000 1120 4620 200 2500 7300 3325 1800 800 80 820 Anchor Bolt M30X800 125 All measurements are in millimeters (mm) GEDigitalEnergy.com 15

LW13A-550/Y 550kV DTB Outline Drawing 550kV SF 6 Breaker LW13A-420 / LW13A-550 Phase C Phase B 8000 8000 Phase A 2850 2450 I 80 (1000) (1180) R=845 800 800 1100 300 1500 6190 8395 105 Anchor Bolt M30X1000 2150 800 150 3195 1600 1000 1000 125 All measurements are in millimeters (mm) 16 GEDigitalEnergy.com

800kV SF 6 Breaker LW13-800 eneral Assembly Drawing LW13-800 DTB 11000 11000 10249 7607 4681 3000 12108 12966 13146 560 3820 LCP 1680 Grounding Block Ground 2000 3820 500 630 1460 1580 P1 Terminal Pad 36 65 65 65 65 220 3864 4239 65 190 800 4523 5620 500 P1 P1 LCP 9-Ø24 R900 Aluminum Alloy Plate P2 P2 P2 40 Size of Grounding Block 70 15 100 130 Copper Soldering 70*70 15 70 GEDigitalEnergy.com 17

Technical Specifications Main Technical Data of 72.5kV-800kV Dead Tank Circuit Breaker* PRODUCT TYPE LW24-72.5 LW24-126 LW24-145 LW24-252 LW23-363 LW13A-363 LW13A-420 LW13A-550 LW13-800 1. Electrical Parameters 1. 1 Rated voltage (kv) 72.5 126 145 252 363 363 420 550 800 1. 2 Rated frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50 50 50/60 1. 3 Rated continuous current (A) 3150 3150 3150 4000 3150/4000 1. 4 Rated short circuit breaking current (ka) 3150/4000/ 5000 5000 5000 5000 40 40 31.5/40 50/63 50 50/63 50/63 50/63 50/63 1. 5 Making current (ka) 104 104 80/104 130/164 130 130/164 135/171 135/171 135/171 1. 6 Rated peak withstand current (ka) 104 104 80/104 130/164 130 130/164 135/171 135/171 135/171 1. 7 Specific creepage distance (mm/kv) 25/31 25/31 25/31 25/31 25/31 25/31 25 25 25 1. 8 Short line fault breaking current (ka) 36/30 36/30 28.35/23.63 45/37.5 45/37.5(50kA); 56.7/47.25(63kA) 1. 9 Out of phase breaking current (ka) 10 10 7.875 12.5 12.5(50kA); 15.75(63kA) 1. 10 Rated short-time power-frequence withstand voltage (kv): To earth 160 230 275 460 510 510 650 740 960 1. 11 Rated lightning impulse withstand voltage (kv): To earth 350 550 650 1050 1300 1300 1425 1675 2100 1.12 First pole to clear factor 1.5 1.5 1.5 1.3 1.3 1.3 1.3 1.3 1.3 1.13 Rated short-time withstand duration(s) 4 4 3 3 3 3 3 3 3 PRODUCT TYPE LW24-72.5 LW24-126 LW24-145 LW24-252 LW23-363 LW13A-363 LW13A-420 LW13A-550 LW13-800 2. Mechanical Parameters 2. 1 Type of mechanism Spring Spring Spring Spring/ Hydromechanical Spring/ Hydromechanical Spring/ Hydromechanical Hydro-mechanical 2. 2 Mechanical endurance (times) 5000 5000 5000 5000 5000 5000 5000 5000 5000 2. 3 Rated operating sequence O-0.3s-CO-180s-CO 2. 4 Close time (ms) 100 100 100 110 100 100 100 100 100 2. 5 Open time (ms) 0 0 0 0 20 20 20 20 20 2. 6 Breaking time (ms) 60 60 60 60 40 40 40 40 40 2. 7 Close-open time (ms) 40-50 40-50 40-50 50-70 40-50 40-50 40-50 40-50 40-50 2. 8 Operating asynchronism (ms) Between poles Open Close 2. 9 Operating asynchronism (ms) Across break Open Close 2 4 2. 10 Number of breaks per pole 1 1 1 1 1 2 2 2 2 2. 11 Three phase operation/ single phase 4 5 2 3p 3p 3p 3p/1p 1p 1p 1p 1p 1p 2. 12 Rated SF6 gas pressure (Mpa) 0.4/0.5 0.5 0.5 0.6 0.5 0.5 0.6 0.6 0.6 2. 13 Leakage of SF6 gas per year (%) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 2. 14 Weight (kg) 1550 3400 3400 9000 10000 18000 18000 18000 60000 4 2 4 2 4 2 5 2 * Additional products available - see product ordering page for complete listing. 18 GEDigitalEnergy.com

Ordering LW * - * / * * - * SF 6 Circuit Breaker Outdoor LW Design Sequence No. 24 13/ 13A 23 Rated Voltage 72.5 126 145 252 363 420 550 800 Operating System: T: Spring Mechanism T Y: Hydro-mechanical Mechanism Y Rated Current (A) 1250 2000 3150 4000 5000 Rated Interrupting Current (ka) 31.5 40 50 63 Dead Tank Circuit Breaker Product Line With Spring Mechanism: LW24-72.5/T1250-31.5 LW24-72.5/T2000-31.5 LW24-72.5/T2500-31.5 LW24-72.5/T3150-40 LW24-126/T3150-40 LW24-145/T3150-31.5 LW24-145/T3150-40 LW24-252/T4000-50 Dead Tank Circuit Breaker Product Line With Hydro-mechanical Mechanism: LW24-252/Y4000-63 LW23-363/Y3150-50 LW23-363/Y4000-50 LW13A-363/Y3150-50 LW13A-363/Y4000-50 LW13A-363/Y5000-50 LW13A-363/Y3150-63 LW13A-363/Y4000-63 LW13A-363/Y5000-63 LW13A-420/Y5000-63 LW13A-550/Y5000-63 LW13-800/Y5000-63 Ordering Notes: Please provide the following information when ordering: 1. Type, description of product, and type of mechanism. 2. Rated voltage, rated current, short circuit breaking current. 3. Current ratio, accuracy class and quantity, rated output capacity. 4. Pollution class: class III or class IV. 5. Control voltage of mechanism: DC220V or DC110V. 6. Voltage of energy-store motor: AC380V or AC/DC 220V or AC/DC 110V. GEDigitalEnergy.com 19

GEDigitalEnergy.com Digital Energy Toll Free: +1 877-605-6777 Direct: +1 678-844-6777 gedigitalenergy@ge.com GE, the GE monogram, Primary Plus and Multilin are trademarks of the General Electric Company. g XD Electric is a registered trademark of China XD Electric Group. XIHARI is a registered trademark of the Xi an High Voltage Apparatus Research Institute Co., Ltd. IEC is a registered trademark of Commission Electrotechnique Internationale. IEEE is a registered trademark of the Institute of Electrical Electronics Engineers, Inc. ISO is a registered trademark of the International Organization for Standardization. OSHA is a registered trademark of the U.S. Department of Labor. KEMA is a registered trademark of DNV. GE Digital Energy reserves the right to make changes to specifications of products described at any time without notice and without obligation to notify any person of such changes. Copyright 2014, General Electric Company. GEA-12723D(E) English 140812