Speed Controller with One-touch Fitting

Similar documents
Speed Controller with One-touch Fitting

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Speed Controller with Indicator

Speed Controller with Indicator

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications

Port size. Part no. M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/ UNF NPT 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2. Specifications

Flow Control Equipment

Port size AK AK AK AK /04 AK /10. Specifications

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 ASP330F-N01 ASP430F-N02 ASP530F-N03 ASP630F-N04

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

For Pneumatic Piping/Fittings & Tubing Prior to Use

How to Order. M5 M5 x 0.8 U10/ UNF

Miniature Regulator Series ARJ310

Standard Specifications

Transmitters: Relay Valve VR4151/4152

Speed Controller High Flow

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Precision Clean Regulator

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

SPEED CONTROLLERS WITH QUICK FITTINGS

Push-In Fitting Type Quick Exhaust Valve

Exhaust Throttle (Needle) Valve ET

Standard Specifications

Two Hand Control Valve

Throttle (Needle) Valve PP Series

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Throttle (Needle) Valve Standard Series

Rectangular Multi-connector. No. of Connecting Tubes: 10, 20. Plate. Plug connector Socket connector PAT.PEND

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Standard Specifications

Multi-Circuit Rotary Block

Rectangular Multi-connector. No. of Connecting Tubes: 10, 20. Plate. Plug connector Socket connector PAT.PEND

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

One-touch Fittings 23% 24% 57% KQ2-G Series CAT.ES50-39A. 30% reduction. force 20% reduction 1. Stainless Steel. Improved tube insertion/removal

Transmitters: Relay Valve

Related Products VR4151/4152 Relay Valve

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Connector Series. Multiple Push-In Fitting Type. Desorption of Several Tubes at One Time. Combinable Connectors by Connector Band.

Tube Fitting Stainless SUS316 Compression Fitting Series

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Port size in the cylinder side M5,10-32UNF M5,10-32UNF M3, M5,10-32UNF 1 8, 1 4, M3, M5,10-32UNF M5,10-32UNF 4, M5,10-32UNF 4, 8 564

Series AV2000/3000/4000/5000

F LOW CONTROL EQUIPMENT SPEED CONTROLLERS ACCESSORIES MOUNTING BRACKET NOW ALSO WHITE AS2001F AS2051F AS3001F AS4001F ORDER LINES

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Minimal Fitting Series

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

Insert Fittings. Series KF. Superior tube mounting. A reliable seal Holds the tube tightly

Push-In Fitting Type Speed Control Valve Speed Controller Series

Main Block Series. Concentrated Branching Joint for Assembly. Assembling Manifold Blocks for Concentrated Branching

Push-In Fitting Type Speed Control Valve Speed Controller Series

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

Miniature Fittings Stainless Steel 316. Hose nipple. Barb Configuration for easy insertion into the tube Holds the tube tightly.

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Check Valve Series AK How to Order

In-line Filter of Easy Maintenance

ARM1000/2000. Standard Specifications

PVC Quick Drain Valve

Digital Catalog. Operation can be made from the toolbar at the center of the lower portion of the screen.

Specifications. Fluid Operating pressure range Proof pressure Operating temperature range Filtration Element proof pressure differential

Tube Fitting Stainless SUS316 Series

Valve Built-in self-seal mechanism. Air does not exhaust after removal of tubing. Stopper Cushion. Release button(blue) Guide Collet Chuck

Pressure Relief 3 Port Valve With Locking Holes

Plug: KBP Elbow module: KBV Female connector union: KBH. Tubing. Guide. Chuck Collet. O-ring Lock ring. Spring Spring guide. Specifications.

Vacuum Switch with LED display

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

SUPPLY JOINTS CONTENTS

Pressure Switch with Super slim LED Display

Low Maintenance Filter

Valve for Water and Chemical Base Fluids

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC

FIT-2. Inch. Ø Â" to Ë" O/D tube

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

45% 6.5 mm. 6 mm. 4 mm. Compact Cylinder. Compact. lighter. JCQ Series CAT.ES20-239C. Weight. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

How to Order. Body size

Conventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Rotary Actuators Precautions 1 Be sure to read this before handling.

Low Maintenance Filter

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

EISELE IS QUALITY MADE IN GERMANY AVAILABLE ON STOCK IN GRAND RAPIDS, MI

ZFC Series. Air Suction Filter. In-line Type with One-touch Fittings

Series CYP. ø15, ø32 Clean Rodless Cylinder. How to Order

Transmitters: Relay Valve VR4151/4152

Power Valve Precision Regulator

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Tube Fitting Anti-spatter Series

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Automatic exchange of robot hand tools, FMS (flexible manufacturing system) implemented for assembly lines.

Series CYP. Clean rodless cylinder ø15, ø32. How to Order

Miniature Fittings Series M

Applicable Tubing. Tubing material Note1) Tubing O.D. Note 1) ø2 is available in polyurethane only. Specifications

Miniature Fittings Stainless Steel 316. Hose nipple. Barb. Configuration for easy insertion into the tube Holds the tube tightly.

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

Transcription:

Speed Controller with One-touch Fitting Series Elbow Type Reduces labor time! Elbow Brass Stainless steel Electroless nickel plated Stainless steel 33 RoHS TMH y Easo t e us Push-lock type Larger handle Easy to lock Body size Unlock Lock D ød (mm) -FE KE 9 -FG 11.6 (Port size ) -FP 1 ød 2 12.6 (Port size ) 3 -FM 4 17.6 -D -T P N AQ V AK Improved tube insertion/removal VCHC S Max. Insertion force: 3% (8 N) reduction R Q Max. Removal force: 2% (5 N) reduction Tube pulling out strength is ensured to be equivalent to existing model. Series newly added! More space beneath the tube. Easier installation/removal of the tube. Existing model G thread 17.1 mm 12.2 mm New Stainless steel type Uni thread Elbow type/made to Order added 22 1F-2- SA 22 1F-2- Vaseline/-X12 Throttle valve/-x214 Grease-free + Throttle valve/-x21 Clean/- 474

Series Flow rate reproducibility Improved reproducibility of flow rate Stable handle position when fully closed (no flow rate) onto the contact face stopper (rotating stopper). Small variations in flow rate depending on the number of handle rotations Fully closed Stopper face Contact face stopper Easy identification of product type Series Series -F Release button color Meter-out Meter-in Metric Inch Gray Light blue Light gray Orange Gray Light blue White White Series -F-U Series -FG G thread Stainless steel type Uni thread 475

Speed Controller with One-touch Fitting Electroless nickel plating type is standardized. G thread (face seal) is standardized. Series Variations Stainless steel type (stainless steel 33) is standardized. Seal method Gasket seal Body size 1 Port size M5 x.8-32unf 2 3.2 4 Metric size 6 8 Applicable tubing O.D. 12 16 Inch size " 5/32" " 5/16" 3/8" " Metal parts material Applicable tubing material TMH D Sealant 2 Face seal Gasket seal 2 3 4 2 3 4 2 3 4 R NPT G 1 Uni 3/8 3/8 3/8 Brass/ Steel wire Stainless steel 33 Brass/ Steel wire Nylon (T, TIA Series) Soft nylon (TS, TISA Series) Polyurethane (T, TIUB Series) Fluororesin (TLM, TILM Series) (TH, TIH Series) -FE KE -FG -FP -FM -D -T P N AQ V AK VCHC S R Q 1 Face seal is applicable only to G. 2 Non-sealant type can be selected as a standard option. Push-lock Series Variations Speed Controller with Indicator/Series -FS Flow rate 5 Numerical indication of handle rotation for flow rate reduces flow setting time and setting errors! Body size Port size 1 to 4 M5 to Applicable tubing O.D. Metric size Inch size ø2 to ø16 ø" to ø" Refer to the WEB catalog for details. 475-1

Speed Controller with One-touch Fitting Elbow Type Series RoHS Model Model Elbow type 121F-M5 121F-U/32 221F-1 221F-2 321F-2 321F-3 421F-4 221F-G1 221F-G2 321F-G2 321F-G3 Port size Seal method 2 Note 2) M5 x.8-32unf Gasket seal R NPT G 3/8 3/8 Sealant Note 1) Face seal 421F-G4 Note 1) Non-sealant type can be selected as a standard option. Note 2) Only polyurethane tubing is applicable for ø2. 3.2 4 Metric size 6 8 Applicable tubing O.D. 12 16 " 5/32" Inch size " 5/16" 3/8" " Flow Direction Symbols on Body Meter-out type Meter-in type Symbol Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure.1 MPa Ambient and fluid temperature 5 to 6 C(No freezing) Applicable tubing material Nylon, Soft nylon, Polyurethane Note), FEP, PFA Note) Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the WEB catalog or Best Pneumatics No. 6 for details.) Caution Be sure to read before handling. Refer to back cover for Safety Instructions. For Flow Control Equipment Precautions, refer to Handling Precaution for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com 476 Flow Rate and Sonic Conductance Model Tubing O.D. b values: Critical pressure ratio Metric size Inch size Free flow Controlled flow 121F-M5 221F-1 Note) 221F-2 321F 421F ø2 C values: Free Sonic flow.2 conductance Controlled dm 3 /(s bar) flow.2.3 ø3.2 ø4 ø6 ø" ø" ø5/32".2.3.3.4 ø3.2 ø4 ø" ø" ø5/32" ø" ø5/32" ø5/16".4.4.2.6.7 ø6 ø8 ø.6.8.3 ø3.2.7.6.3 ø6 ø8 ø ø12 ø6 ø8 ø ø ø12 ø16 ø" ø5/16" ø" ø5/16" ø3/8" ø3/8" ø" ø3/8" 1.3 1.5 1.6 1.7 2.5 4.4 4.8.2.3.3.3 Note 1) -32 UNF has the same specification as M5. Note 2) C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed. Note 3) The same specifications also apply to the -FG series (stainless steel type). ø4 1..9 1.3.4 2.1 2.4 3.3 4.4.4.3.3.3 4.9

Speed Controller with One-touch Fitting Series Body size 1 Body size 2/3/4 1 2 3 4 Body size M5 x.8-32unf How to Order 1 2 1F M5 6 A 2 2 1F 1 6 S A Body size, 3/8 Type 2 Elbow Control type Note) Meter-out 1 Meter-in Note) Meter-out and meter-in types can be visually identified by color of the handle. Meter-out: Gray Meter-in: Light blue M5 U/32 Metal parts material Nil Standard type (Brass, Steel wire) G Stainless steel type (Stainless steel 33) Note 1) The material can be visually identified by color of the release button. Stainless steel type: White Note 2) White is also used for inch size. Thread type Nil R N NPT G G Port size M5 x.8-32unf Applicable tubing O.D. Note 1) Metric size Inch size 2 23 4 6 ø2 ø3.2 Note 2) ø4 ø6 1 3 7 ø" ø5/32" ø" Note 1) For selecting applicable tubing O.D., refer to Series Variations (Page 475-1). Metric size and inch size types can be visually identified by color of the release button. Metric size: Light gray Inch size: Orange Note 2) Use ø" tube. Made to Order Refer to page 481-2 for details. Push-lock type Seal method Nil Without sealant S With sealant Note) Face seal method is used for thread type G. Select Nil/Without sealant. Ex.) 221F-G1-6A Applicable tubing O.D. Note 1) Metric size Inch size Note 3) 23 ø3.2 Note 2) 1 ø" 4 ø4 3 ø5/32" 6 ø6 7 ø" 8 ø8 9 ø5/16" ø 11 ø3/8" 12 ø12 13 ø" 16 ø16 Note 1) For selecting applicable tubing O.D., refer to Series Variations (Page 475-1). Note 2) Use ø" tube. Note 3) Only the metric size is available for the G thread. Port size 1 2 3 4 3/8 TMH D -FE KE -FG -FP -FM -D -T P N AQ V AK VCHC S R Q 477

Series Needle Valve/Flow-rate Characteristics 121F-M5, 1211F-M5 Flow rate [L/min (ANR)] Inlet pressure:.5 MPa 5 1, 23, 3, 4, 6, 7 2 5 Note) -U/32 has the same specification as M5. 321F, 3211F 221F-1, 2211F-1 Flow rate [L/min (ANR)] 3 Inlet pressure:.5 MPa 2 6, 7, 8, 9, 1, 23 5 421F-4, 4211F-4 3, 4 221F-2, 2211F-2 Flow rate [L/min (ANR)] 6 Inlet pressure:.5 MPa 5 4 3 2 8, 9,, 11 6, 7 3, 4 1, 23 5 Inlet pressure:.5 MPa Inlet pressure:.5 MPa Flow rate [L/min (ANR)] 5, 11, 12 8, 9 6, 7 Flow rate [L/min (ANR)] 15 5 12, 13, 16, 11 5 5 Note 1) The numbers above the flow-rate characteristic curves in the charts show the applicable tubing outside diameter as defined by the product number. Note 2) The same characteristics also apply to the -FG series (stainless steel type). 478

Speed Controller with One-touch Fitting Series Construction/ Elbow Type Seal method: Gasket seal Thread type: M5, -32UNF o! Meter-in type Meter-out type e q t r u i y w!1 o Seal method: Sealant Thread type: R, NPT! Meter-out type e q t r u i y w Meter-in type TMH D -FE KE -FG -FP -FM -D -T Seal method: Face seal Thread type: G e P N o! q t r u AQ V AK VCHC S i R Q!2 Meter-out type y w Meter-in type Component Parts No. Description Series -F Series -FG Material Note Material Note 1 2 3 4 5 6 7 8 9 11 12 Body A Body B Handle Needle Needle guide U-seal O-ring O-ring Cassette Seal Gasket Seal PBT Brass POM PBT Steel wire HNBR NBR NBR NBR NBR/Stainless steel NBR Electroless nickel plating Zinc chromated PBT Stainless steel 33 POM PBT Stainless steel 33 HNBR NBR NBR NBR NBR/Stainless steel NBR 479

Series Thread type: M5, -32UNF Dimensions/ Elbow Type Seal method: Gasket seal Thread type: M5, -32UNF ød3 Applicable tubing O.D. ød L3 L4 A ød1 H (Width across flats) M L1 L2 T Metric Size Model 121F-M5-2A 121F-U/32-2A 121F-M5-23A 121F-U/32-23A 121F-M5-4A 121F-U/32-4A 121F-M5-6A 121F-U/32-6A Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation Note 3) The value in ( ) is the dimensions of FG type. 2 d 3.2 4 6 T M5 x.8 /32UNF (mm) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) Weight (g) M Unlock Lock Unlock Lock -F type -FG type 5.8 Note 3) 7.2 9 (8) 9 8.2.4 15.8 17.2 18.6 2.6 22 23.4 16.9 16.5 26.5 25.4 23.5 22.4 11.9 5 6 5 6 Inch Size Model 121F-M5-1A 121F-U/32-1A 121F-M5-3A 121F-U/32-3A 121F-M5-7A 121F-U/32-7A Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation Note 3) The value in ( ) is the dimensions of FG type. d " 5/32" " T M5 x.8 /32UNF L4 Note 1) A Note 2) H D1 D3 L1 L2 L3 M Unlock Lock Unlock Lock 7.2 Note 3) 9 (8) 8.2 9 11.2 17.2 18.6 22 23.4 16.9 16.5 26.5 25.4 23.5 22.4 (mm) Weight (g) -F type -FG type 5 5 6 6 48

Speed Controller with One-touch Fitting Series Thread type: R, NPT Dimensions/ Elbow Type Seal method: Sealant Thread type: R, NPT ød3 Metric Size Model L4 d A L3 T H (Width across flats) ød1 Applicable tubing O.D. ød L4 Note 1) A Note 2) H D1 D3 L1 L2 L3 M Unlock Lock Unlock Lock M L1 L2 T (mm) Weight (g) -F type -FG type 221F-1-23(S)A 3.2 7.2 9 (9) 9 (9) 221F-1-4(S)A 4 8.2 19.1 26.1 (26) 13 221F-1-6(S)A 6.4 11.6 19.1 3.6 29.2 27.5 26.1 (9) (9) (12.7) 221F-1-8(S)A 8 13.2 22.4 29.4 (29.3) 14.2 11 () 11 () 221F-1-(S)A 15.9 25.3 32.3 (32.2) 12 (11) 12 (11) 221F-2-23(S)A 3.2 7.2 2.9 3 (3.3) 221F-2-4(S)A 4 8.2 18 (19) 17 (18) 17 221F-2-6(S)A 6.4 12.6 23.4 32.5 (32.8) 22.6 36.6 35 31.1 29.5 (17.5) 221F-2-8(S)A 8 13.2 23.9 33 (33.3) 14.2 19 (2) 18 (19) 221F-2-(S)A 15.9 26.9 36 (36.3) 2 (21) 19 (2) 321F-2-6(S)A 6.4 21.8 32.1 4 (4) 4 (4) 36.4 321F-2-8(S)A 8 13.2 22.7 33 14.2 41 (41) 41 (41) 19 5 48.4 44.5 42.9 321F-2-(S)A 15.9 26.7 37 35.7 42 (42) 42 (42) 321F-2-12(S)A 12 18.5 29.7 4 34.5 17 43 (43) 43 (43) 321F-3-6(S)A 6.4 21.8 32.1 28.7 31 (32) 29 (3) 321F-3-8(S)A 8 13.2 22.7 33 14.2 3/8 19 42.3 4.7 37.1 35.5 321F-3-(S)A 15.9 26.7 37 28 32 (33) 3 (31) 321F-3-12(S)A 12 18.5 29.7 4 26.8 17 34 (35) 32 (33) 421F-4-(S)A 15.9 27.4 4.3 (4.2) 36.2 54 (53) 52 (51) 24 421F-4-12(S)A 12 18.5 17.6 3.8 43.7 (43.6) 35.1 5.8 49.2 43.7 42.1 17 56 (55) 54 (53) (23.8) 421F-4-16(S)A 16 23.8 34.8 47.7 (47.6) 32.7 2.6 6 (59) 58 (57) Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation Note 3) The values in ( ) are the dimensions of NPT thread. TMH D -FE KE -FG -FP -FM -D -T P N AQ V AK VCHC S R Q Inch Size (mm) Model d T H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) Weight (g) M Unlock Lock Unlock Lock -F type -FG type 221F-1-1(S)A " 7.2 19.1 26.1 (26) 9 (9) 9 (9) 221F-1-3(S)A 5/32" 13 8.2 11.6 19.1 3.6 29.2 27.5 26.1 221F-1-7(S)A " (12.7) 11.2 2.8 27.8 (27.7) (9) (9) 221F-1-9(S)A 5/16" 13.2 22.4 29.4 (29.3) 14.2 11 () 11 () 221F-2-1(S)A " 7.2 2.9 3 (3.3) 18 (19) 17 (18) 221F-2-3(S)A 5/32" 8.2 17 221F-2-7(S)A " 11.2 12.6 23.4 32.5 (32.8) 22.6 36.6 35 31.1 29.5 19 (19) 18 (18) (17.5) 221F-2-9(S)A 5/16" 13.2 23.9 33 (33.3) 14.2 19 (2) 18 (19) 221F-2-11(S)A 3/8" 15.5 26.4 35.5 (35.8) 2 (21) 19 (2) 321F-2-7(S)A " 11.2 21.8 32.1 4 (4) 4 (4) 36.4 321F-2-9(S)A 5/16" 19 13.2 22.7 33 5 48.4 44.5 42.9 14.2 41 (41) 41 (41) 321F-2-11(S)A 3/8" 15.5 26.7 37 35.9 321F-3-7(S)A " 11.2 21.8 32.1 28.7 321F-3-9(S)A 5/16" 3/8 19 13.2 22.7 33 42.3 4.7 37.1 35.5 14.2 31 (32) 29 (3) 321F-3-11(S)A 3/8" 15.5 26.7 37 28.2 32 (33) 3 (31) 421F-4-11(S)A 3/8" 24 15.5 27.4 4.3 (4.2) 36.2 54 (53) 52 (51) 17.6 5.8 49.2 43.7 42.1 421F-4-13(S)A " (23.8) 19.3 3.9 43.8 (43.7) 34.7 17 56 (55) 54 (53) Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation Note 3) The values in ( ) are the dimensions of NPT thread. 481

Series Thread type: G Dimensions/ Elbow Type Seal method: Face seal Thread type: G ød3 Applicable tubing O.D. ød L3 L4 A ød1 H (Width across flats) M L1 L2 T Metric Size Model 221F-G1-23A 221F-G1-4A 221F-G1-6A 221F-G1-8A 221F-G1-A 221F-G2-23A 221F-G2-4A 221F-G2-6A 221F-G2-8A 221F-G2-A 321F-G2-6A 321F-G2-8A 321F-G2-A 321F-G2-12A 321F-G3-6A 321F-G3-8A 321F-G3-A 321F-G3-12A 421F-G4-A 421F-G4-12A 421F-G4-16A d 3.2 4 6 8 3.2 4 6 8 6 8 12 6 8 12 12 16 T 3/8 L4 A H D1 D3 L1 L2 L3 M Unlock Lock Unlock Lock 7.2 8.2 19.1 26.1 13.4 11.6 18.8 3.3 17 13.2 15.9 7.2 8.2.4 13.2 15.9 12.6 22.4 25.3 2.9 23.4 23.9 26.9 29.4 32.3 3 32.5 32.6 36 22.6 36.6.4 21.8 32.1 36.4 13.2 22.7 33 19 5 15.9 26.7 37 35.7 18.5 29.7 4 34.5.4 21.8 33 28.7 13.2 22.7 33.9 21 42.3 15.9 26.7 37.9 28 27 18.5 15.9 18.5 23.8 17.6 29.7 27.4 3.8 34.8 4.9 41.8 45.2 49.2 26.8 36.2 35.1 32.7 5.8 28.9 35 48.4 4.7 49.2 24.8 3.1 43.5 34.8 41.8 23.4 28.5 41.9 33.2 4.2 14.2 14.2 14.2 17 14.2 17 17 2.6 (mm) Weight (g) -F type -FG type 11 11 12 12 21 2 22 21 23 22 5 5 52 52 53 53 38 37 39 38 4 39 42 41 72 69 74 71 78 75 481-1

Series Made to Order Specifications: Please contact SMC for detailed dimensions, specifications, and delivery. 1 Lubricant: Vaseline -X12 X12 X214 Laser printing Ex.) 221F-1-4SA-X12 3 Throttle Valve (Without Check Valve) -X214 Laser printing Ex.) 221F-1-4SA-X214 Note) Throttle valve is only compatible with the part no. of the meter-out type. 2 Grease-free (Seal: Fluorine Coating) + Throttle Valve (Without Check Valve) -X21 X21 - Laser printing Ex.) 221F-1-4SA-X21 4 Clean - Laser printing Note 1) Not particle-free Note 2) Throttle valve is only compatible with the part no. of the meter-out type. Note 3) Only the needle and O-ring are fluorine-coated. Ex.) -221F-1-4SA Note 1) Fluorine grease is used. Note 2) The particulate generation grade is 3. TMH D -FE KE -FG -FP -FM -D -T P N AQ V AK VCHC S R Q 481-2

Speed Controller with Uni One-touch Fitting Series New-stand male threads for piping that reduces the screw-in time by 1/3. Model Uni thread Shape of Uni thread ridge Use of the chamfered surface of the female thread as the seat surface and adoption of gaskets made by laminating NBR on both surfaces of stainless steel plates achieve secure sealing regardless of the difference of diameters due to the female thread type, deviations due to the tolerance, or the size of the chamfered corner. (Any standard chamfered female thread can be used.) A ridge shape has been created as a Uni thread for common applications for Rc, G, NPT and NPTF. The gasket seal method drastically cuts piping man-hours. Flow Direction Symbols on Body Meter-out type Meter-in type Symbol Caution Gasket Female thread Be sure to read before handling. Refer to back cover for Safety Instructions. For Flow Control Equipment Precautions, refer to Handling Precaution for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com Model Elbow type 221F-U1 221F-U2 321F-U2 321F-U3 3/8 421F-U4 Specifications Applicable tubing O.D. Metric size Inch size 3.2 4 6 8 12 16 " 5/32" " 5/16" 3/8" " Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure.1 MPa Ambient and fluid temperature 5 to 6 C (No freezing) Applicable tubing material Nylon, Soft-nylon, Polyurethane Note) Note) Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the WEB catalog or Best Pneumatics No. 6 for details.) Flow Rate and Sonic Conductance Tubing O.D. C values: Sonic conductance dm 3 /(s bar) Model b values: Critical pressure ratio Metric size Inch size Free flow Controlled flow Free flow Controlled flow 221F-1 221F-2 321F-3 421F-4 ø3.2 ø4 ø" ø5/32".4.4 Connection thread Uni thread.2.6.7 ø6 ø8 ø ø" ø5/16".6.8.3 ø3.2 ø4 ø6 ø8 ø ø12 ø6 ø8 ø ø ø12 ø16 ø" ø" ø5/32" ø5/16" ø" ø5/16" ø3/8" ø3/8" ø" ø3/8".7 1. 1.3 1.5 1.6 1.7 2.5 4.4 4.8.6.9.2.3.3.3 Note) C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed. 1.3 2.1 2.4 3.3 4.4.3.4.4.3.3.3 4.9 481-3

Speed Controller with Uni One-touch Fitting Series How to Order 2 2 1 F U1 6 A Body size 2, Type 3 3/8 2 Elbow 4 Control type Meter-out 1 Meter-in Meter-out and meter-in types can be visually identified by color of the handle. Meter-out: Gray Meter-in: Light blue With One-touch fitting Needle Valve/Flow-rate Characteristics 221F-U1, 2211F-U1 3 Inlet pressure:.5 MPa Flow rate [L/min(ANR)] 2 6, 7, 8, 9, 3, 4 1, 23 U1 U2 U3 U4 Port size Uni Uni Uni 3/8 Uni 221F-U2, 2211F-U2 Flow rate [L/min(ANR)] 6 5 4 3 2 Inlet pressure:.5 MPa Push-lock type Applicable tubing O.D. Note 1) Metric size Inch size Tubing O.D. Tubing O.D. 23 4 6 8 12 16 ø3.2 Note 2) ø4 ø6 ø8 ø ø12 ø16 1 3 7 9 11 13 ø" ø5/32" ø" ø5/16" ø3/8" ø" Note 1) For selecting applicable tubing O.D., refer to Series Variations (Page 475-1). Metric size and inch size types can be visually identified by color of the release button. Metric size: Light gray Inch size: Orange Note 2) Use ø" tube. 8, 9,, 11 6, 7 3, 4 1, 23 TMH D -FE KE -FG -FP -FM -D -T P N AQ V AK VCHC S R Q 5 321F-U3, 3211F-U3 5 421F-U4, 4211F-U4 Flow rate [L/min(ANR)] 5 Inlet pressure:.5 MPa, 11, 12 15 8, 9, 11 6, 7 Flow rate [L/min(ANR)] 5 Inlet pressure:.5 MPa 12, 13, 16 5 5 Note) The numbers above the flow-rate characteristic curves in the charts show the applicable tubing outside diameter as defined by the product number. 481-4

Series Construction Elbow Type 221F-U1-6A o! e q t Meter-in type Meter-out type r u i y!1 w Component Parts No. Description Material Note 1 2 3 4 5 6 7 8 9 11 Body A Body B Handle Needle Needle guide U-seal O-ring O-ring Cassette Seal Gasket PBT Brass POM PBT Steel wire HNBR NBR NBR NBR NBR/Stainless steel Electroless nickel plating Zinc chromated 481-5

Speed Controller with Uni One-touch Fitting Series Dimensions/ Elbow Type ød3 L4 A L3 H (Width across flats) ød1 Applicable tubing O.D. ød Metric Size (mm) Model d T L4 Note 1) A Note 2) H D1 D3 L1 L2 L3 Uni thread Unlock Lock Unlock Lock M Weight (g) 221F-U1-23A 3.2 7.2 9 (9) 221F-U1-4A 4 8.2 19.1 26.1 (26) 13 221F-U1-6A 6.4 11.6 19.1 3.6 29.2 27.5 26.1 (9) (12.7) 221F-U1-8A 8 13.2 22.4 29.4 (29.3) 14.2 11 () 221F-U1-A 15.9 25.3 32.3 (32.2) 12 (11) 221F-U2-23A 3.2 7.2 2.9 3 (3.3) 221F-U2-4A 4 8.2 17 (18) 17 221F-U2-6A 6.4 12.6 23.4 32.5 (32.8) 22.6 36.6 35 31.1 29.5 (17.5) 221F-U2-8A 8 13.2 23.9 33 (33.3) 14.2 18 (19) 221F-U2-A 15.9 26.9 36 (36.3) 19 (2) 321F-U2-6A 6.4 21.8 32.1 36.4 39 (39) 321F-U2-8A 8 13.2 22.7 33 14.2 19 5 48.4 44.8 43.2 321F-U2-A 15.9 26.7 37 35.7 4 (4) 321F-U2-12A 12 18.5 29.7 4 34.5 17 42 (42) 321F-U2-6A 6.4 21.8 32.1 28.7 39 (39) 321F-U2-8A 8 13.2 22.7 33 28 14.2 3/8 19 42.3 4.7 37.1 35.5 321F-U2-A 15.9 26.7 37 28 4 (4) 321F-U2-12A 12 18.5 29.7 4 26.8 17 42 (42) 421F-U4-A 15.9 27.4 4.3 (4.2) 36.2 52 (51) 24 421F-U4-12A 12 18.5 17.6 3.8 43.7 (43.6) 35.1 5.8 49.2 43.7 42.1 17 54 (53) (23.8) 421F-U4-16A 16 23.8 34.8 47.7 (47.6) 32.7 2.6 58 (57) Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation Note 3) The values in ( ) are the dimensions of NPT thread. M L1 L2 T TMH D -FE KE -FG -FP -FM -D -T P N AQ V AK VCHC S R Q Inch Size (mm) Model d T L4 Note 1) A Note 2) H D1 D3 L1 L2 L3 Uni thread Unlock Lock Unlock Lock M Weight (g) 221F-U1-1A " 7.2 19.1 26.1 (26) 9 (9) 221F-U1-3A 5/32" 13 8.2 11.6 19.1 3.6 29.2 27.5 26.1 221F-U1-7A " (12.7) 11.2 2.8 27.8 (27.7) (9) 221F-U1-9A 5/16" 13.2 22.4 29.4 (29.3) 14.2 11 () 221F-U2-1A " 7.2 2.9 3 (3.3) 17 (18) 221F-U2-3A 5/32" 8.2 17 221F-U2-7A " 11.2 12.6 23.4 32.5 (32.8) 22.6 36.6 35 31.1 29.5 18 (18) (17.46) 221F-U2-9A 5/16" 13.2 23.9 33 (33.3) 14.2 18 (19) 221F-U2-11A 3/8" 15.5 26.4 35.5 (36.3) 19 (2) 321F-U2-7A " 11.2 21.8 32.1 36.4 321F-U2-9A 5/16" 19 13.2 22.7 33 5 48.4 44.8 43.2 14.2 39 (39) 321F-U2-11A 3/8" 15.5 26.7 37 35.9 4 (4) 321F-U3-7A " 11.2 21.8 32.1 28.7 321F-U3-9A 5/16" 3/8 19 13.2 22.7 33 42.3 4.7 37.1 35.5 14.2 39 (39) 321F-U3-11A 3/8" 15.5 26.7 37 28.2 4 (4) 421F-U4-11A 3/8" 24 15.5 27.4 4.3 (4.2) 36.2 52 (51) 17.6 5.8 49.2 43.7 42.1 421F-U4-13A " (23.8) 19.3 3.9 43.8 (43.7) 34.7 17 54 (53) Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation Note 3) The values in ( ) are the dimensions of NPT thread. 481-6

Series Specific Product Precautions 1 Be sure to read before handling. Refer to back cover for Safety Instructions. For Flow Control Equipment Precautions, refer to Handling Precaution for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com Design/Selection Warning 1. Check the specifications. The products in this catalog are designed to be used in compressed air systems (including vacuum) only. If the products are used in an environment where pressure or temperature is out of the specified range, damage and/or malfunction may result. Do not use under such conditions. (Refer to the specifications.) Please contact SMC when using a fluid other than compressed air (including vacuum). We do not guarantee against any damage if the product is used outside of the specification range. 2. The products in this catalog are not designed for the use as stop valve with zero air leakage. A certain amount of leakage is allowed in the product's specifications. Tightening the needle to reduce leakage to zero may result in equipment damage. 3. Do not disassemble the product or make any modifications, including additional machining. It may cause human injury and/or an accident. 4. The flow-rate characteristics for each product are representative values. The flow-rate characteristics are characteristics of each individual product. Actual values may differ depending on the piping, circuitry, pressure conditions, etc. 5. Sonic conductance (C) and critical pressure ratio (b) values for products are representative values. The speed controller s controlled flow values are with the needle fully open and free flow with the needle fully closed. 6. Check if PTFE can be used in application. PTFE powder (Polytetrafluoroethylene resin) is included in the seal material for piping taper thread of male thread type. Confirm that the use of it will not cause any adverse effect on the system. Please contact SMC if the Material Safety Data Sheet (MSDS) is required. Warning 1. Operation manual Mounting Install the products and operate them only after reading the operation manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary. 2. Ensure sufficient space for maintenance activities. When installing the products, allow access for maintenance. 3. Tighten threads with the proper tightening torque. When installing the products, follow the listed proper torque. Warning Mounting 4. After pushing the handle down to lock, confirm that it is locked. It should not be possible to rotate the handle to the right or to the left. If the handle is pulled with force, it may break. Do not pull the handle with excessive force. Locked Unlocked 5. Check the degree of rotation of the needle valve. The products in this catalog are retainer type so that the needle is not removed completely. Over rotation will cause damage. 6. Do not use tools such as pliers to rotate the handle. It can cause idle rotation of the handle or damage. 7. Verify the air flow direction. Mounting backward is dangerous, because the speed adjustment needle will not work and the actuator may lurch suddenly. 8. Adjust the speed by opening the needle slowly from the fully closed state. Loose needle valves may cause unexpected sudden actuator lurching. When a needle valve is turned clockwise, it is closed and actuator speed decreases. When a needle valve is turned counterclockwise, it is open and actuator speed increases. 9. Do not apply excessive force or shock to the body or fittings with an impact tool. It can cause damage or air leakage.. Refer to the Fittings & Tubing Precautions of Best Pneumatics No. 6 for handling One-touch fittings. 11. Tubing O.D. ø2 Tubing other than that from SMC cannot be used, because it may result in inability to connect the tube, air leakage after connecting the tube or disconnection of the tube. 12. To install/remove the product, use an appropriate wrench to tighten/loosen at the supplied nut on body B. Do not apply torque at other points as the product may be damaged. Rotate body A manually for positioning after installation. 482

Series Specific Product Precautions 2 Be sure to read before handling. Refer to back cover for Safety Instructions. For Flow Control Equipment Precautions, refer to Handling Precaution for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com Warning 13. Do not use body A for applications involving continuous rotation. Body A and the fitting section may be damaged. Caution For M5, -32UNF Body size M5 3/8 ød 45 Female thread size M5 Body A Body B Tightening method First, tighten it by hand, then give it an additional 1/6 turn to turn with a wrench. A reference value for the tightening torque is 1 to 1.5 N m. Note) Excessive tightening may damage the thread portion or deform the gasket and cause air leakage. If the screw is too shallowly screwed in, it may come loose or air may leak. Chamfered area for female thread 1. Confirming to ISO 163 (air pressure fluid dynamics connection ports and stud ends), the chamfer dimensions shown below are recommended. -32UNF Maximum allowable adjusting torque [N m].5.7.16.2.4 Chamfer dimension ød (Recommended value) 5.1 to 5.4 5. to 5.3 2. This product has a stopper for fully close in rotating direction. Excess torque may break the stopper. Table below shows the maximum allowable torque of the handle. When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. Body B Body A Mounting For R, NPT (With sealant) Tightening method 1. The proper tightening torques of the fittings are as shown in the table below. As a guide, tighten by hand, then turn it two or three turns with a wrench. Check the dimensions of each product for the hexagon width across flats. Connection thread size NPT, R NPT, R NPT, R3/8 NPT, R Proper tightening torque [N m] 3 to 5 8 to 12 15 to 2 2 to 25 Chamfered area for female thread By chamfering as shown in the following table, machining of threads is easier and effective for burr prevention. ød 45 Rz12.5 Connection Chamfer dimension ød (Recommended value) thread size Rc NPT, NPTF 3/8.2 to.4 13.6 to 13.8 17.1 to 17.3 21.4 to 21.6.5 to.7 14.1 to 14.3 17.4 to 17.6 21.7 to 21.9 For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. TMH D -FE KE -FG -FP -FM -D -T P N AQ V AK VCHC S R Q Carefully perform the piping work so that the tool is not in contact with the body A. 483 A

Series Specific Product Precautions 3 Be sure to read before handling. Refer to back cover for Safety Instructions. For Flow Control Equipment Precautions, refer to Handling Precaution for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com Caution For G Thread (Packing Seal Type) Mounting For Uni Thread Tightening method First, tighten the threaded portion by hand, then use a proper wrench, which could be suitable for the width across flats of the hexagon body, to tighten it further at a wrench tightening angle shown in the table below. For a tightening torque guide, see the table below. Check the dimensions of each product for the hexagon width across flats. Connection thread size G G G3/8 G Wrench tightening angle after tightened by hand [deg] to 2 15 to 35 15 to 35 15 to 35 Proper tightening torque [N m] 3 to 4 4 to 5 8 to 9 14 to 15 Chamfered area for female thread (Recommended value) 1. Confirming to 163-21, the chamfered thread sizes shown below are recommended. By chamfering as shown in the following table, machining of threads is easier and effective for burr prevention. Tightening method 1. First, tighten the threaded portion by hand, then use a proper wrench, which could be suitable for the width across flats of the hexagon body, to tighten it further at a wrench tightening angle shown in the table below. For a tightening torque guide, see the table below. Connection Female Thread: Rc, NPT, NPTF UNI thread size 3/8 UNI thread size Wrench tightening angle after tightened by hand [deg] 3 to 6 3 to 6 15 to 45 15 to 3 Connection Female Thread: G 3/8 Wrench tightening angle after tightened by hand [deg] 3 to 45 15 to 3 15 to 3 15 to 3 Tightening torque [N m] 3 to 5 8 to 12 14 to 16 2 to 22 Tightening torque [N m] 3 to 4 4 to 5 8 to 9 14 to 15 ød 45 Rz12.5 2. The gasket can be recycled up to 6 to times. Chamfered area for female thread By chamfering as shown in the following table, machining of threads is easier and effective for burr prevention. Nominal thread size Chamfer dimension ød min. max. 3/8 9.8 16.8 21..2 13.7 17.2 21.4 2. Use G external threads with G internal threads. Connection thread size 3/8 ød 45 Rz12.5 Chamfer dimension ød (Recommended value) G Rc NPT, NPTF.2 to.6.2 to.4.5 to.7 13.6 to 14. 13.6 to 13.8 14.1 to 14.3 17.1 to 17.5 17.1 to 17.3 17.4 to 17.6 21.4 to 21.8 21.4 to 21.6 21.7 to 21.9 For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 483-1

Series Specific Product Precautions 4 Be sure to read before handling. Refer to back cover for Safety Instructions. For Flow Control Equipment Precautions, refer to Handling Precaution for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com Piping Threads with Sealant Caution 1. If the fitting is tightened with excessive torque, a large amount of sealant will seep out. Remove the excess sealant. 2. Insufficient tightening may loosen the threads, or cause air leakage. 3. Reuse 1) Normally, fittings with a sealant can be reused 2 to 3 times. 2) To prevent air leakage through the sealant, remove any loose sealant stuck to the fitting by blowing air over the threaded portion. 3) If the sealant no longer provides effective sealing, wrap pipe tape over the sealant before reusing. Do not use the sealant in any form other than a tape type. 4. Once the fitting has been tightened, backing it out to its original position often causes the sealant to become defective. Air leakage will occur. 5. Use R external threads with Rc internal threads and NPT external threads with NPT internal threads. Piping Caution 1. Refer to the Fittings & Tubing Precautions of Best Pneumatics No. 6 for handling One-touch fittings. 2. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. 3. Wrapping of pipe tape When screwing together pipes and fittings, etc., be certain that chips from the pipe threads and sealing material do not get inside the pipe. Also, when the pipe tape is used, leave approx. 1 thread ridges exposed at the end of the threads. Wrapping direction TMH D -FE KE -FG -FP -FM -D -T P N AQ V AK VCHC S R Q Expose approx. 1 thread Pipe tape 483-2

Speed Controller with One-touch Fitting Universal Type INFORMATION Universal Brass Electroless nickel plated RoHS Universal type added! 36 swivel piping possible Model Applicable tubing O.D. Model Port size Seal method Metric size 3.2 4 6 8 12 131F-M5 M5 x.8 Gasket seal 231F-1 231F-2 331F-2 R Sealant Note) 331F-3 3/8 431F-4 Note) Non-sealant type can be selected as a standard option. Flow Direction Symbols on Body Meter-out type Meter-in type Symbol Specifications Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Applicable tubing material Note) Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the WEB catalog or the Best Pneumatics No. 6 for details.) Air 1.5 MPa 1 MPa.1 MPa 5 to 6 C (No freezing) Nylon, Soft nylon, Polyurethane Note), FEP, PFA Caution Be sure to read before handling. For Safety Instructions and Flow Control Equipment Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, http:// www.smcworld.com Flow Rate and Sonic Conductance Model 131F-M5 231F-1 231F-2 331F 431F ø3.2 Tubing Metric ø6 ø8 ø ø4 ø3.2 ø4 ø4 ø6 ø6 ø8 ø ø12 O.D. size ø8 ø ø12 ø6 C values: Sonic conductance dm 3 /(s bar) b values: Critical pressure ratio Free flow Controlled flow Free flow Controlled flow.3.4.6.6.7 1. 1.3 1.5 1.6 1.7 2.5 4.4 4.8.3.4.7.8.6.9 1.3 2.1 2.4 3.3 4.4 4.9.4.2.3.3.4.4.3.3.2.2.3.3.3.3 Note) C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed. Series 13-E616

Series Universal Brass How to Order Electroless nickel plated Width across flats (H) dimension E 8 mm Nil 9 mm Applicable tubing O.D. Note 1) Metric size 23 ø3.2 Note 2) 4 ø4 6 ø6 Note 1) For selecting applicable tubing O.D., refer to Model (Front cover). Note 2) Use ø" tube. Body size 1 M5 x.8 Port size M5 M5 x.8 Body size 1 Body size 2/3/4 1 3 1F M5 E 6 A 2 3 1F 1 6 S A Body size 2, 3 3/8 4 Type 3 Universal Control type Note) Meter-out 1 Meter-in Note) Meter-out and meter-in types can be visually identified by color of the handle. Meter-out: Gray Meter-in: Light blue Push-lock type Seal method Nil Without sealant S With sealant Applicable tubing O.D. Note 1) Metric size 23 ø3.2 Note 2) 4 ø4 6 ø6 8 ø8 ø 12 ø12 Note 1) For selecting applicable tubing O.D., refer to Model (Front cover). Note 2) Use ø" tube. Port size 1 2 3 3/8 4 1

Speed Controller with One-touch Fitting Series Needle Valve/Flow-rate Characteristics 131F-M5, 1311F-M5 231F-1, 2311F-1 231F-2, 2311F-2 Flow rate L/min (ANR) 5 Inlet pressure:.5 MPa 23, 4, 6 Flow rate L/min (ANR) 3 2 Inlet pressure:.5 MPa 6, 8 4 23 Flow rate L/min (ANR) 6 5 4 3 2 Inlet pressure:.5 MPa 8, 6 4 5 5 5 331F, 3311F 431F, 4311F Inlet pressure:.5 MPa Inlet pressure:.5 MPa Flow rate L/min (ANR) 5, 12 8 6 Flow rate L/min (ANR) 15 5 12 5 5 Note) The numbers above the flow-rate characteristic curves in the charts show the applicable tubing outside diameter as defined by the product number. 2

Series Construction/ Universal Type Seal method: Gasket seal Thread type: M5 Seal method: Sealant Thread type: R!1!1!2!3 w! r q y t i o u e!2 w! r q y t i o Meter-in type Meter-out type!4 u e Meter-in type Meter-out type Component Parts No. Description Material Note 1 Body A PBT 2 Elbow body PBT 3 Body B Brass Electroless nickel plating 4 Handle POM 5 Needle PBT 6 Needle guide Brass Electroless nickel plating 7 U-seal HNBR 8 O-ring NBR 9 O-ring NBR O-ring NBR 11 Cassette 12 Seal NBR 13 Spacer Note) PBT 14 Gasket NBR/Stainless steel Note) Spacer is included only for the applicable tubing O.D. ø3.2. 3

Speed Controller with One-touch Fitting Thread type: M5 Series Dimensions/ Universal Type Seal method: Gasket seal Thread type: M5 Applicable tubing O.D. ød ød1 ød3 L4 ød4 A L5 L3 M H(Width across flats) ød2 L1 L2 T Metric Size Model d T H D1 D2 D3 L1 L2 L3 L4 131F-M5E-23A 3.2 7.2 11.6 19.4 17.5 33.8 131F-M5E-4A 4 M5 x.8 8 8.2 9.6 9 19.8 11.5 131F-M5E-6A 6.4 2.9 2.4 36.6 Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation (mm) L5 Note 1) A Note 2) M Weight (g) Unlock Lock Unlock Lock 26.5 25.4 23.5 22.4 6 4

Series Thread type: R Dimensions/ Universal Type Seal method: Sealant Thread type: R Applicable tubing O.D. ød ød1 ød3 L4 ød2 L5 A L3 M H(Width across flats) T L1 L2 Metric Size (mm) L5 Model d T H D1 D2 D3 L1 L2 L3 L4 Note 1) A Note 2) M Weight Unlock Lock Unlock Lock (g) 231F-1-23(S)A 3.2 7.2 24 17.5 36 231F-1-4(S)A 4 8.2 9.6 13 11.6 13.9 25.1 3.6 29.2 27.5 26.1 231F-1-6(S)A 6.4 26.2 2.4 38.8 11 231F-1-8(S)A 8 13.2.2 16.4 3.1 21.5 4 14.2 12 231F-2-4(S)A 4 8.2 16.5 29.9 17.5 4.1 19 231F-2-6(S)A 6.4 33.7 21.4 43.9 21 17 12.9 12.6 19 36.6 35 31.1 29.5 231F-2-8(S)A 8 13.2 34.7 23.5 46 14.2 22 231F-2-(S)A 15.9 2.9 38 24.7 47.3 23 331F-2-6(S)A 6.4 12.9 2.2 36.1 21.4 57.8 42 331F-2-8(S)A 8 13.2 37.1 23.5 59.9 14.2 43 19 5 48.4 44.5 42.9 331F-2-(S)A 15.9 41.2 26.1 58 46 17.4 23 331F-2-12(S)A 12 18.5 42.5 28.3 6.2 17 48 331F-3-6(S)A 6.4 12.9 2.2 36.1 21.4 5.1 34 331F-3-8(S)A 8 13.2 37.1 23.5 52.2 14.2 35 3/8 19 42.3 4.7 37.1 35.5 331F-3-(S)A 15.9 41.2 26.1 5.3 38 17.4 23 331F-3-12(S)A 12 18.5 42.5 28.3 52.5 17 4 431F-4-(S)A 15.9 17.4 24 17.6 25.6 46.4 26.1 61.2 61 5.8 49.2 43.7 42.1 431F-4-12(S)A 12 18.5 21 26.2 48.3 28.3 63.4 17 64 Note 1) Reference dimensions Note 2) Reference dimensions of threads after installation 5

Series Specific Product Precautions 1 Be sure to read before handling. For Safety Instructions and Flow Control Equipment Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com Design/Selection Warning 1. Check the specifications. The products in this catalog are designed to be used in compressed air systems (including vacuum) only. If the products are used in an environment where pressure or temperature is out of the specified range, damage and/or malfunction may result. Do not use under such conditions. (Refer to the specifications.) Please contact SMC when using a fluid other than compressed air (including vacuum). We do not guarantee against any damage if the product is used outside of the specification range. 2. The products in this catalog are not designed for the use as stop valve with zero air leakage. A certain amount of leakage is allowed in the product s specifications. Tightening the needle to reduce leakage to zero may result in equipment damage. 3. Do not disassemble the product or make any modifications, including additional machining. It may cause human injury and/or an accident. 4. The flow-rate characteristics for each product are representative values. The flow-rate characteristics are characteristics of each individual product. Actual values may differ depending on the piping, circuitry, pressure conditions, etc. 5. Sonic conductance (C) and critical pressure ratio (b) values for products are representative values. The speed controller s controlled flow values are with the needle fully open and free flow with the needle fully closed. 6. Check if PTFE can be used in application. PTFE powder (Polytetrafluoroethylene resin) is included in the sealant for taper pipe thread of male thread type. Confirm that the use of it will not cause any adverse effect on the system. Please contact SMC if the Material Safety Data Sheet (MSDS) is required. Mounting Warning 1. Operation manual Install the products and operate them only after reading the operation manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary. 2. Ensure sufficient space for maintenance activities. When installing the products, allow access for maintenance. 3. Tighten threads with the proper tightening torque. When installing the products, follow the listed proper torque. 4. After pushing the handle down to lock, confirm that it is locked. It should not be possible to rotate the handle to the right or to the left. If the handle is pulled with force, it may break. Do not pull the handle with excessive force. Warning 5. Check the degree of rotation of the needle valve. The products in this catalog are retainer type so that the needle is not removed completely. Over rotation will cause damage. 6. Do not use tools such as pliers to rotate the handle. It can cause idle rotation of the handle or damage. 7. Verify the air flow direction. Mounting backward is dangerous, because the speed adjustment needle will not work and the actuator may lurch suddenly. 8. Adjust the speed by opening the needle slowly from the fully closed state. Loose needle valves may cause unexpected sudden actuator lurching. When a needle valve is turned clockwise, it is closed and actuator speed decreases. When a needle valve is turned counterclockwise, it is open and actuator speed increases. 9. Do not apply excessive force or shock to the body or fittings with an impact tool. It can cause damage or air leakage.. Refer to the Fittings & Tubing Precautions of Best Pneumatics No. 6 for handling One-touch fittings. 11. To install/remove the product, use an appropriate wrench to tighten/loosen at the supplied nut on body B. Do not apply torque at other points as the product may be damaged. Rotate body A manually for positioning after installation. 12. Do not use body A and/or elbow body for applications involving continuous rotation. Body A and the fitting section may be damaged. Elbow body Caution For M5 Mounting Body A Body B Tightening method First, tighten it by hand, then give it an additional 1/6 turn to turn with a wrench. A reference value for the tightening torque is 1 to 1.5 N m. Note) Excessive tightening may damage the thread portion or deform the gasket and cause air leakage. If the screw is too shallowly screwed in, it may come loose or air may leak. Chamfered area for female thread 1. Conforming to ISO 163 (air pressure fluid dynamics connection ports and stud ends), the chamfer dimensions shown below are recommended. ød Female thread size Chamfer dimension ød (Recommended value) M5 5.1 to 5.4 Locked Unlocked 45 6

Series Specific Product Precautions 2 Be sure to read before handling. For Safety Instructions and Flow Control Equipment Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, http://www.smcworld.com Caution Body A Body B Mounting 2. This product has a stopper for fully close in rotating direction. Excess torque may break the stopper. Table below shows the maximum allowable torque of the handle. Body size Maximum allowable adjusting torque [N m] M5.5.7.16 3/8.2.4 3. When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. For R (With sealant) Tightening method Carefully perform the piping work so that the tool is not in contact with the body A. 1. The proper tightening torques of the fittings are as shown in the table below. As a guide, tighten by hand, then turn it two or three turns with a wrench. Check the dimensions of each product for the hexagon width across flats. Connection thread size Proper tightening torque [N m] R 3 to 5 R 8 to 12 R3/8 15 to 2 R 2 to 25 Chamfered area for female thread By chamfering as shown in the following table, machining of threads is easier and effective for burr prevention. ød Rz 12.5 Connection thread size Chamfer dimension ød (Recommended value) Rc.2 to.4 13.6 to 13.8 3/8 17.1 to 17.3 21.4 to 21.6 Piping Threads with Sealant Caution 1. If the fitting is tightened with excessive torque, a large amount of sealant will seep out. Remove the excess sealant. 2. Insufficient tightening may loosen the threads, or cause air leakage. 3. Reuse 1) Normally, fittings with a sealant can be reused 2 to 3 times. 2) To prevent air leakage through the sealant, remove any loose sealant stuck to the fitting by blowing air over the threaded portion. 3) If the sealant no longer provides effective sealing, wrap sealing tape over the sealant before reusing. Do not use the sealant in any form other than a tape type. 4. Once the fitting has been tightened, backing it out to its original position often causes the sealant to become defective. Air leakage will occur. 5. Use R external threads with Rc internal threads. Piping Caution 1. Refer to the Fittings & Tubing Precautions of Best Pneumatics No. 6 for handling One-touch fittings. 2. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. 3. Wrapping of sealant tape When screwing together pipes and fittings, etc., be certain that chips from the pipe threads and sealant do not get inside the pipe. Also, when the sealant tape is used, leave approx. 1 thread ridges exposed at the end of the threads. Wrapping direction Expose approx. 1 thread Sealant tape 45 Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E3-3) before using.