Safety Considerations

Similar documents
TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Universal Fluid Power Trainer (UFPT)

WindLab TM Wind Turbine Power System Sample Laboratory Procedure Manual

Universal Fluid Power Trainer (UFPT)

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

University of Jordan School of Engineering Mechatronics Engineering Department. Fluid Power Engineering Lab

The Discussion of this exercise covers the following points:

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

UNIVERSAL, INDEPENDENT DUAL SYSTEM HYDRAULIC TEST STAND

LABORATORY SAFETY SERIES: Electrical Safety

Linear Flexible Joint Cart Plus Single Inverted Pendulum (LFJC+SIP)

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

Operating and Installation Instructions

: Automation Laboratory 1

ILCS EDGE System Installation Manual

QUICK START GUIDE 199R10546

EE 370L Controls Laboratory. Laboratory Exercise #E1 Motor Control

Electro-Proportional Terms and Definitions

TurboGen TM Gas Turbine Electrical Generation System Sample Lab Experiment Procedure

TurboGen TM Gas Turbine Electrical Generation System Sample Lab Experiment Procedure

AR2000 Rheometer: Instructions

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE Centrifugal Pump(Armfield)

SUPER DUTY, INDEPENDENT DUAL SYSTEM HYDRAULIC POWER UNIT / DIESEL POWERED

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

ILCS EDGE Jr EDP Installation Manual

SAP E & C ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (FOR ITI) (PRODUCT CODE: SAP 20B-I)

HYDROTRAINER-200 Hydraulics - Electro-hydraulics

Operation & Service Manual

TERMINATOR User Manual

Experiment 6: Induction

Hydraulic Proportional and Closed Loop System Design

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

SHOCK ABSORBER/DAMPER TESTING MACHINE

LEARNING ACTIVITY PACKET MECHATRONICS PICK AND PLACE FEEDING B72001-AA03UEN

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

R I T. Title: Westech 372 Polisher Semiconductor & Microsystems Fabrication Laboratory Revision: C 08/07/07 1 SCOPE 2 REFERENCE DOCUMENTS

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Ex. 1-1 Nacelle Familiarization and Safety Discussion

MF100BH (BASIC HYDRAULICS TRAINER) PARTS LIST CATALOG APRIL 2013

Advanced User Manual

Model: AEM14 Analog Engine Monitor

Geo-Prime Tank. Table of Contents. Installation, Operation & Maintenance Instructions AFCG1PT Revision: 7/3/14. Replacing a Pump 12

Active Controlled Cooling System

SECTION B: SYSTEM OPERATING COMPONENTS

Rotary Motion Sensor

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement

Series 111 Accumulator Product Information

The pneumatic circuit and parts' list needed to perform this operation are shown by Figure C.1.

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

Geo-Prime Tank U.S. Patent Number 8,544,282

PHYS 2212L - Principles of Physics Laboratory II

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science

E-training. Positioners (Pneumatic, Electro pneumatic, I to P converters) Pneumatically actuated valves can be positioned in a number of ways.

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

EBS PRODUCTS

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

MAGPOWR Spyder-Plus-S1 Tension Control

Permanent Magnet DC Motor

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Powered Industrial Truck Safety Program

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

Electric Drives Experiment 3 Experimental Characterization of a DC Motor s Mechanical Parameters and its Torque-Speed Behavior

Starting up hydraulic systems

Dynojet Research, Inc. All Rights Reserved. Air Fuel Ratio Module Installation and User Guide.

Commander IS0128 ISO128E ECR# /04. Tachometer/ Engine Hourmeter

AQUIS Foam System. Installation, Operation, and Maintenance Instructions AQUIS 1.5, AQUIS 3.0, and AQUIS 6.0

Model MF200 Cavitation Simulator OWNERS MANUAL

SECTION B1: MACHINE COMPONENTS

HANDS-ON INDUSTRIAL TRAINING FLUID SENSORS SIMULATION SOFTWARE E-LEARNING CERTIFICATION PREPARATION

"ELECTRICAL SAFETY IN THE LABORATORY"

Inverted Pendulum Control: an Overview

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 551A-B LITHIUM-ION BATTERY CHARGER WITH CHARGE TERMINATION

Marine Engineering Exam Resource Review of Hydraulics

PRESSURE SENSOR INSTRUCTIONS

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Startup and Operation of SEE-THRU Nuclear Power Plant for Student Performance MP-SEE-THRU-01 Rev. 018

Lesson 1: Introduction to PowerCivil

Definitions of Technical Terms

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

V PicoScope NVH Diagnostics Overview

HS CYCLIC CUM STATIC TRIAXIAL TEST SYSTEM

ECE 5671/6671 Lab 5 Squirrel-Cage Induction Generator (SCIG)

Washer Extractor. Balancing Systems

MF100 SPECIFICATIONS & FEATURES

Motor Tuning Instructions

Customer Name: Serial Number: Y-Axis Stall

Exercise 7. Thyristor Three-Phase Rectifier/Inverter EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Thyristor three-phase rectifier/inverter

Tachometer (RPM Feedback) General

HIGH PRESS. - HIGH TEMP. (HPHT) FILTER PRESS 4 - UNIT ASSEMBLY 175 ml Capacity - OFI No

X-Tractor Series. Cutters INSTRUCTION MANUAL

Appendix A: Motion Control Theory

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439

Models

Subject: Pneumatic Training Kit with portable Air Compressor

ECU1000 ELECTRONIC CONTROL UNIT

Transcription:

Safety Considerations The following safety rules MUST BE FOLLOWED to ensure safety in the laboratory. General Considerations No smoking, eating or drinking in the laboratory. Hydraulic oil in its vapor state can be flammable, and electronic components may be shorted by spilled beverages. Note the locations of the two fire extinguishers, first aid kit, and telephone. Use common-sense safety precautions. Do not work alone. Many hundreds of thousands of dollars have been invested in this laboratory. Treat it as if it were your own. Hydraulic Trainer Stand Precautions Power on the hydraulic system only after hydraulic circuitry has been checked by a qualified instructor! Verify that actuator (cylinders and motor) path is free of clothing, fingers, rags, hoses and all other objects. Check all guards and verify that they are securely in place. Check reservoir oil level. Check for leaks. Check all connections to valves and actuators, including quick connect couplings. Verify that they are securely connected and that the safety lock on the quick couplings is activated. Verify that the relief valve is set at 0 psi at start-up. Do not exceed a maximum system pressure of 500 psi. Stand clear of bench on initial start-up of the hydraulic system. 1

Reference: Trainer Stand Usage & Overview Bul. 0229 Industrial Hydraulic Trainer Stand Lab Manual, Parker Hannifin Corporation, 1981 This section is intended to familiarize you with the Parker Hannifin Hydraulic Trainer Stand. Read this thoroughly and complete the exercise at the end of this supplement BEFORE attempting any lab exercise. Introduction The Parker Hannifin Industrial Hydraulic Trainer Stand is an educational tool. It is used in industry to train workers and engineers in the proper use of hydraulic equipment. It is also used to teach people how to diagnose problematic hydraulic systems. The Electro Hydraulic option, with which our trainer stands come equipped, is used to teach more advanced electronic motion control concepts. In this laboratory, the stand will be used to demonstrate control ideas. Basic concepts such as plant identification and closed loop PID control can be taught on these stands, while nonlinear effects such as deadband and valve stiction exhibited by the components can be used to address advanced topics such as nonlinear and adaptive control. EXTREME CAUTION should be followed when working with the components. Common sense safety practices should be followed and close attention paid to the instructor at all times. READ the safety guidelines sheet before attempting the exercise at the end of this handout. Apparatus A diagram of the trainer stand appears in Figure 1. For this exercise we will be using the lever actuated directional control valve (43) to control the motor (41). A similar procedure would be followed if one were to use a different valve or actuator. In a hydraulic system, the pump provides fluid pressure and flow. This flow and pressure can be converted by one of the actuators (motor or cylinder in our case) to do useful work. Directional valves, such as the one we will be using, simply direct the fluid flow in one direction or another. A proportional valve, such as the D1FS (38) will not only control the direction of the fluid flow, but also a percentage of the full pump flow rate in that direction. 2

Figure 1 Parker Hannifin Hydraulic Trainer Stand Schematic Fused start-stop button Heavy duty castors (2 fixed, 2 swivel) Solenoid selector switch System pressure gage 3.5 GPM gear pump Electric motor, 115V, 1Hp System pressure relief valve Ball valve for venting system pressure relief valve Motor isolation mount Ball valve for demonstrating cavitation Vacuum gage Liquid level gage with thermometer Needle valve for demonstrating aeration Aeration filter 10 gallon reservoir Filler/breather 10 micron filter with indicator Pressure, drain and tank manifold Work bench Sequence valve Pressure reducing valve Check valve Hydraulic cylinder, 6 stroke Linear position sensor for cylinder rod Flow control Check valve 6 rod piston scale Flow control valve 3 Pressure compensated flow control Needle valve 8 sets of hose assemblies with quick disconnect on an integral rack plus (2) tees and (1) cross Hydraulic cylinder w/ guard, 12 stroke Deceleration valve Tapered cam Pressure gage (2) Flow meter Electronic control box Electro hydraulic proportional control valve Hydraulic motor magnetic pickup Hydraulic motor sensing gear Hydraulic motor with guard Solenoid operate 4-way closed center directional control valve Lever operate 4-way open center directional control valve Electrical cord (not shown) Storage cabinet 1 quart accumulator with gas precharge pressure gage down block

The pump (5) draws hydraulic oil from the reservoir (15) and pumps it into the system. The oil passes through the relief valve (7) and into the manifold (18). A properly configured relief valve causes the system pressure never to exceed a preset limit. The manifold is a convenient interface for hose connections. It has pressure (from the pump) and drain (to the reservoir) couplings. The manifold is analogous to the battery in electronic circuits the pressure couplings are the high potentials, and the drain couplings are the low potential. From the manifold, various valves and actuators can be connected in a circuit to produce the desired work effect. For this exercise, we will not be using the electro hydraulic control box (37). It is used to control the electro hydraulic valve (38) only. Objective Proper completion of this trainer exercise will require that you: Follow safety guidelines for using the hydraulic trainer stand. Learn the proper start up and shut down procedure for minimal pump stress and personal safety. Understand the basics of hydraulic circuitry. Experiment The goal of the following steps is to enable the hydraulic motor. It will spin quickly when the system is powered on, so verify that the protective covering around the gear is secure. Follow these steps: Connect the circuit. Take a hose from the cabinet (45) and connect a high pressure outlet (18) to the P port on valve (42). Using another hose, connect the T port on valve (42) to one of the return couplings (18). Now, connect either the A or B port on the valve (42) to one port of the hydraulic motor (41). Connect the other port on the motor to the remaining valve coupling. Caution: Sometimes, it will matter which valve port A or B is connected to the actuator. In this case it does not. Check that the system pressure gauge (4) reading is almost 0 psi. The pressure gauge will never actually reach 0 psi. Verify that the ball valve, relief vent (8) is completely on. Steps (2) and (3) above make sure that the pump is unloaded when the system is started. With the current setup, the pump will simply return all fluid to the reservoir, and the manifold connections will be unpressured. Ask a qualified instructor to check the circuitry. This step should always be followed. 4

The solenoid switch (3) should be in the off position before starting the system. Locate the pump pressure gage (4). Watch this gage closely. If it ever exceeds 500 psi, turn off the pump immediately. Locate the power switch (1). Stand clear of the trainer stand and turn it on. The pump pressure gage (4) should remain near zero psi. Close the ball valve, relief vent (8). All of the fluid is still being pumped into the reservoir. However, now the fluid must travel through the relief valve. The pump pressure should remain at zero. SLOWLY, start closing the relief valve (7). The pump pressure should increase. Set the pressure to be about 150 psi. The system is powered up at this point, but the motor is not turning because the valve is shutting off all flow. Try switching the solenoid valve selector switch (3) from off to A, then to B. Observe the motor. Check the RPMs of the motor on the digital display on (37). NEVER exceed 500psi! Increase and decrease the pressure by opening and closing the relief valve (7) and observe the effect of pressure on the motor RPMs. The solenoid switch (3) should be in the off position before shutting the system down. Slowly back out the relief valve all the way. The system pressure should be close to 0 psi. Open the ball valve, relief vent, all the way. The system is back to where it was before the pump was started. Turn off the pump. Disconnect the quick coupling hoses and put them away. Neatly. The steps in italics are the steps that should be followed whenever the trainer stand is used. Different valves and actuators may be used, but the startup and shutdown procedures remain the same, always. If time permits, try connecting to the manual directional control valve (43) instead of the solenoid directional control valve (42). Follow the same procedure as before. Instead of two solenoids, the flow is controlled by the lever. Note: When setting the relief valve pressure (7) for the lever controlled valve, put the lever in position A or B while setting the pressure. If you leave it neutral, the pressure will never increase, as the off position of the valve is actually a short circuit. Ask the instructor for an explanation. 5

Computer Control and Data Acquisition Reference: Wincon 3.0 Manual This section is intended to familiarize you with Wincon 3.0. Read it thoroughly and do the exercise at the end of this supplement BEFORE attempting any lab exercises. Introduction Quanser Consulting produces a software and hardware package that allows a user to collect and generate real time electronic signals using a Windows based PC. The main strength of the system is that external signals can be used as inputs into a Simulink block diagram, manipulated, and then output as real signals. The hardware portion consists of the MultiQ A/D and D/A (analog to digital and digital to analog) board. It fits into a standard PC expansion slot. An external terminal attaches via ribbon cable to the MultiQ card. The external terminal consists of coaxial cable connections. Signals are received and generated by the MultiQ board. The software package that controls the hardware is called Wincon 3.0. Wincon 3.0 takes a Simulink block diagram, generates C code based on the diagram, and compiles the code. It then loads a user interface that looks much like a toolbar. This toolbar controls the starting and stopping of the controller, in addition to graphing and saving options. Apparatus The MW2000 is a signal conditioning box that has been built about the MultiQ external terminal board. The box has 38 available connections, include 8 analog and digital inputs and outputs. It also has 6 optical encoder inputs. All cables must be plugged into this interface. Matlab and Simulink are the two computer programs that provide the basis for the Wincon System. Knowledge of the two is essential in order to use Wincon. Objectives Proper completion of this exercise will require that you: (1) Create a Simulink block diagram controller based on an available template. (2) Compile the block diagram. (3) Configure and start Wincon. (4) Modify controller parameters in real time. (5) Save data. 6

Experiment The goal of the following exercise is to record a signal that has been generated by Simulink. Follow these steps: (1) Start Matlab and Simulink. Open the Simulink model, N:\HydraulicsLab\ME460 \template.mdl. The template has certain compiler options that have been preset, in addition to some required Wincon blocks. It is recommended that you always start with this template, unless you want to figure out the compiler options yourself. This is not recommended! (The timer-block is always required in all block diagrams to be used with Wincon. The analog input and output block are not required unless you need to use them. The Simulink library for these blocks can be retrieved by typing winlib at the Matlab prompt.) (2) Create the controller. The controller has already been created for you. Configure the block titled Sine Wave to have an amplitude and frequency of your choosing. (3) Set ADC and DAC options. Double click on the analog input and analog output blocks. Select the desired channels in the Channels to use section. In this case, use analog output channel 0 and analog input channel 4. (4) Set the sampling interval. Go to the menu item Wincon. Select Options. Click on the Solver tab. Enter the appropriate sample time for your application. In this case choose 0.005. (5) Verify that the proper ODE solver is selected. Choose Fixed step ODE (Euler) for this laboratory in the same menu as Step 4. This solver will be adequate for most needs. (6) Save the block diagram. Make a directory with your alias in C:\ME460. Save the block diagram in this directory. Make sure that this directory matches the Current Directory being called by Matlab. (7) Compile the block diagram. Go to the menu item Wincon. Select build. Various status messages will be printed in the Matlab window. (8) Turn on the MW2000. The power switch is in the very back of the blue box with the white front panel. (9) Make physical connections. Connect a coaxial cable between Channel 0 in Analog output and Channel 4 in Analog input. The signal generated in Channel 0 is now immediately read by Channel 4. Usually, the signal would be directed into some device which would use the output, and the input signal would be something you want to measure, like a tachometer signal. (10) Open the desired plot windows. This is done via the graph icon on the Wincon toolbar. Select the desired signal to plot. (11) Select the variables to plot. In the plot window, select the File menu and choose Variables. Pick as many variables as you want plotted in this window. (12) Set buffer, axis and refresh options. In general, pick the smallest buffer size (in seconds) that you need in order to capture all of your data. Set this under the Update menu, Buffer option. In some applications you may wish to select Freeze plot under the Update menu. This will cause Wincon to capture one screen full of data and then stop plotting. In this exercise, do not select this option. Finally set various axis range options. (13) Start the controller. Press the start button on the Wincon toolbar. (14) Modify the controller parameters by using the slider gain. Observe the effects. (15) Stop the controller. 7

(16) Save data as.m file. The save option is under the File menu. Save in your directory in c:\me460 (17) Turn off the MW2000. The steps in italics are the steps that should be followed whenever Wincon is used. If time permits, try changing the channel number in the analog output or input block in the Simulink block diagram. Change the cables to match the changes in the block diagram. Recompile the code and run the controller using Wincon again. Observe differences, if any. Also try generating a sine wave of about 2000 HZ, and inputting it into Channel 7 in the Analog Inputs (you will have to change the block parameters and recompile). Change the sine wave s frequency to 1000 HZ. What s going on? 8