Type SJK Test Switches

Similar documents


Type MTS Miniature Test Switches

circuit protection & wiring accessories

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series

REV: 000. Super Seca Flash Cure Units

Installation, Maintenance & Parts Manual

AMENDMENT ELECTRIC SERVICE MANUAL 2014

BETA Fuses and Fuse Systems

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

circuit protection & wiring accessories

Installation, Maintenance & Parts Manual

SPECIFICATION BULLETIN

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

2200 Series Center Drive Conveyors

TM ETRS-TM35FIN-ETRS89 WTG

Push Button Units and Indicator Lights

The Product Range. Technical Data

circuit protection & wiring accessories

Disconnect & ByPass Switches

Partner for Change : Appendix A

Issue/Rev. 0.3 (2/04) Bulletin P

Parts List, Wiring Diagrams

SELECTION LIST REVISION This book contains the following models: Chevy/GMC Dodge Ford

Fuse Panels, Fuse Holders and Fuses

Table 1d - FSA for All Returns, Females Tax Year

Set-up, Operation & Maintenance Manual

M MA. M MA 125mA M205-2A M MA M MA M MA M MA. M MA 100mA M A 1.6A

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

PRIME 3-BURNER PROPANE BARBECUE Assembly Manual

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Installation, Maintenance & Parts Manual

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

NH HRC Fuses. IEC & British Standard Fuses NHG B

SECTION PANELBOARDS

Fuse Panels, Fuse Holders and Fuses

Installation, Maintenance & Parts Manual

10 Commercial, Industrial, Agricultural Services

ches UL File No. E101598

SPARE CONNECTORS 2008

4100 Series End Drive Conveyors

PRIME 3-BURNER PROPANE BARBECUE Assembly Manual

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

66M C5 4 x 50, Category 5, 66M connecting block clip. 10"H x 3.4"W x 1.25"D

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

There are many pre-designs of Vulkan launcher.

Horizontal Circuit Switchers

Horizontal Circuit Switchers

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

ANR SPECIFICATIONS. MATERIALS RoHS COMPLIANT - E222871

3RG4 BERO Inductive Proximity Switches

AIR CYLINDER Series A12, A13

Fuse Blocks and Holders Fuse Block Technical Data Fuse Blocks 250 Volt E4 600 Volt E5 Cartridge Fuse Pullers Fuse Holders. ATC / Mini Fuse Tabs

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Illustrated Parts List for GPU-400

SERVICE MANUAL (INTERNATIONAL)

Metering and Service Installation:

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

CON EDISON EQUIPMENT

CONTENTS TERMINAL BLOCKS

Industrial Control Transformers

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Main catalogue. ESSAILEC Test Blocks

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Bussmann series Quik-Spec Power Module Switch elevator disconnect

ELECTRICAL PANELS. Chap.

Vacuum Automation 2.1. The future depends on good product choices

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

Fuse Blocks and Clips

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Design Standard. Purpose: Design Standard:

Combined pump and gripper Medium

Door Locks. Pocket Door Hardware. Folding Door Lock ST10641 CD1064-US3 Brass 5 $18.80

and legacy Motor Control Center Aftermarket Renewal Parts Catalog

A02 SERIES PUSHBUTTON SWITCHES, ILLUMINATED OR NON-ILLUMINATED Panel cut-out.866" (22mm) or 1.161" x.846" (29.5mm x 21.5mm)

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

Jordair Electrical Parts

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

SELECT 3-BURNER PROPANE BARBECUE Assembly Manual

# Order nr article description quantity 1 MMA chassis, drive 1 2 MMA tank, side cover 1 3 MMA handle-bars 1 4 MMA 01

Catalog Number Identification with Elements Explained

Instructions for Replacing

THD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Bussmann series IEC cylindrical fuses

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Issued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller

Switches & Motor Controls

MODEL ELC-12/40-CVM-D BATTERY CHARGER

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

Tie rods cylinders to ISO standard

TH200-4R (MW9) Note: Not all items are available for all transmissions

RU Series Universal Relays

Range : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)

Transcription:

Type SJK Test Switches No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together DESCRIPTION STATES Type SJK Test Switches have long been used for providing a reliable, simple means to test meters, relays and instrument transducers and for control system calibration, disconnection, troubleshooting, checkout and testing. Make-before-break short-circuiting elements for current transformer circuits and test jacks are available. Each switch blade can be operated independently or, where necessary, adjacent handles can be ganged for simultaneous operation. All configurations are available in front-connected, backconnected or flush-mounted styles. Front-connected switches usually are mounted on the same side of the panel as the wiring. Back-connected switches are mounted on one side of the panel, and the wiring is on the other side. As an option, clear or opaque plastic covers are available for both front-connected or back-connected switches. Flush-mounted switches match flush- or semiflush-mounted relays, meters, etc., furnished on steel panelboards. They consist of a back-connected switch mounted in an insulated metal cabinet with cover. FEATURES AND BENEFITS Self-extinguishing materials: All non-metallic components are made of self-extinguishing, flame-retardant materials with Underwriters Laboratories best rating for selfextinguishing materials (V-O). Nonferrous material: All current-carrying metallic components, including hardware, are made of highest quality nonferrous materials such as copper, bronze, brass or phosphor bronze. This ensures excellent conductivity and minimizes galvanic action between dissimilar metals. Nickel plating: All current-carrying metallic components, including hardware, have a corrosion-resistant nickel finish that ensures good electrical contact and smooth operation of moving parts even after years of inactivity. Safety-grip handle: A molded handle covers the terminal and includes a lower lip that projects over the metal parts of the switch, thus protecting the operator from contact with live components. One-piece jaw and hinge: One-piece construction of hinge and jaw eliminates unnecessary, multiple connection points. Special blade shape: All blades are shaped so that the edge of the blade enters at a right angle to the jaw; thus, the blade enters and exits the full width of the jaw simultaneously. Test lug: The large corrugated test lug provided for each terminal stud is a secure surface for attaching test clips. Switch jaws: All STATES Test Switches have uniform contact pressure over the full width of the blade. The ping heard when opening the blade is due to the special, spring-grade phosphor bronze used in the jaw. This design ensures an excellent low-resistant contact that will not overheat. Short-circuit jaw: A rugged, make-before-break element is used to short the secondary of a current transformer. Fixed terminal studs: The screw terminals on which wiring connections are made are a part of a rigid, immovable assembly and cannot be turned or backed out. Test jack: The test jack eliminates the possibility of opening current transformer secondaries and permits safe, easy measurements to be made in current circuits without disturbing permanent wiring. A dual-circuit test plug, such as the STATES Part No. 15000, inserted into the test jack puts the measuring instrument in series with the current circuit. The test jack does not carry current except when making a test because it is shunted by a standard switch blade that is opened only when the test jack is used. Color-coded handles: Unless otherwise specified, potential elements have red handles and current elements have black; however, the following other colors are available at additional cost: blue, orange, white, yellow, brown and green. Identification card holder: Each safety grip handle is slotted for insertion of an identification card for marking or coding. Cards are available under Part No. SB67. Bases: Type SJK Test Switches are available in 1-, -, -, 4-, 7- and 10-pole base sizes. The bases are made of rugged, 4 inch, non-tracking material with excellent insulating properties. Extra-wide element separation: Elements are 11 inches center-to-center to allow for easy installation of test leads. 4 STATES TYPE SJK TEST SWITCHES

ORDERING INFORMATION The part numbers under the arrangements on the following pages are for front-connected switches without covers, which are designated by the first three characters in the Part No., 0K. Example: 0K10-E COVERS Any front- or back-connected switch, up to 10 poles, can be ordered with a cover. Covers are available on 4-, 7- and 10-pole bases. Although you may choose a larger base, usually a 1- to 4-pole switch is built on a 4-pole base; a 5- to 7-pole switch is built on a 7-pole base; and an - to 10-pole switch is built on a 10-pole base. To order front-connected switches To order front-connected switches without covers, specify the Part No. shown under the arrangements on the following pages. Example: 0K10-E For covers, change the 0K prefix to one of the following prefixes: Cover Prefix Front-connected, slotted, clear 60K Front-connected, slotted, opaque 0K Example: 60K10-E To order back-connected switches To order back-connected switches without covers, specify the desired arrangement and add the suffix -B. Example: 0K10-E-B Covers are available for 4-, 7- and 10- pole switches. For covers, add the appropriate prefix: Cover Prefix Back-connected, solid, opaque 90K Back-connected, solid, clear 70K Example: 90K10-E-B To order flush-mounted switches Add the prefix G- to the number of the desired arrangement. Example: G-0K10-E Flush-mounted switches are provided with a cover. (The prefix G- mentioned above designates a flush-mounted switch and its standard cover.) SPECIAL ORDERS Special Arrangements: In addition to the typical arrangements shown on the following pages, special arrangements are available. These can be made of any combination of potential or current elements, with a maximum of 10 poles. For more information, refer to the following example and illustrations on Page 47. Example: To order a customized, 10-pole, back-connected switch with a clear, back-connected cover, specify: Switch Type: STATES Type SJK No. of poles: 10-pole test switch *Arrangement: 1-10-1-10-1-10-1 Style: Back-connected Cover: Clear, back-connected *Arrangements should be given as front view of switch, left to right. Handle Colors: The standard colors for handles are red for potential handles and black for current handles. Handles are also available in other colors. To specify non-standard colors, add to the element number the appropriate color code: Color Color Code Color Color Code Black k Red r Blue b White w Green g Yellow y Orange e Brown n To order a switch with handles in non-standard colors, you must specify the arrangement with colors indicated. For example, to order a 10-pole switch with special handle colors, specify: Arrangement: 1k/10g/1y/10b/1e/10r/1w Ganged handles: You may specify a yoking bar to gang adjacent handles. For example, to order a switch with the adjacent potentials ganged, you must specify: Gang all potentials Hinge position: The U in an arrangement indicates the hinge is positioned upside down from the typical arrangement. Bases: An - or 9-pole test switch is built on a 10-pole base. A 5-, 6-, or 7-pole test switch usually is built on a 7-pole base but can be provided on a 10-pole base if desired. OPTIONAL ACCESSORIES Socket Wrench and Insert To speed installation of the terminal nuts on STATES Test Switches, the socket wrench (Part No. 0) and inch insert (Part No. 07) are available. The screwdriver attachment (Part No. 0) makes this wrench your complete meter installation tool. Dual Circuit Plug By inserting the STATES Dual Circuit Plug (Part No. 15000) into the test jack, safe measurement can be made of current transformer secondary current. See Accessories on page 67. STATES TYPE SJK TEST SWITCHES 4

FRONT VIEW 1-POLE (On 1-Pole base unless otherwise noted) 1 0K01-B (1-Pole base) Color Options: 1y 0K01-F 1k 0K01-K (1-pole base) 9 0K01-E (1-Pole base) Other 1-Pole 1-6 0K01-P (-Pole base) 9-6 0K01-E (-Pole base) -POLE (On -pole base unless otherwise noted) -POLE (CONT.) 1 0K0-E (-Pole base) Other -Pole 1/1g 0K0-J4 (-Pole base) 6-1-1-6 0K0-K (4-Pole base) 6--6 0K0-A (4-Pole base) 6-1-6 0K0-V (4-Pole base) -POLE (On 4-Pole base unless otherwise noted) 1-1-1-6 0K0-B (4-Pole base) Color Option: 1y-1y-1y-6 0K0-N (4-Pole base) -6 -POLE (CONT.) 1-11 0K0-C6 (-Pole base) 1-5-5-6 0K0-A7 (4-Pole base) 15-4-6 0K0-A (4-Pole base) 0K0-D (-Pole base) 17-6 0K0-A (4-Pole base) 4-POLE (On 4-pole base unless otherwise noted) 1-1-1-1 0K04-P 1-10-1 0K04-M 0-4 4-POLE (CONT.) 4-1-1-5 0K04-E 6-6-6-7 0K04-G5 9-4-14 0K04-GA 9-9-9-9 0K04-W 9-6-9-6-9-6-9 0K04-Z (7-Pole base) 10-1-1 0K04-K 10-0K04-C7 10-10 0K04-B 1-1 0K04-H 0K04-Q 5-5-1-1 0K04-YA 6-6-6-4-1-1-5 0K04-RA (7-Pole base) 5-POLE (On 7-pole base) 6-1-1-1-1-1-6 1-1 0K0-D (-Pole base) 0K0-T (4-Pole base) Color Option: K-6 0K0-D4 (4-Pole base) 9-9-9-6 0K04-S 1-1-1 0K05-P 6-9-9-9-9-9-6 0K04-D 0K0-B (-Pole base) Color Option: y 0K0-N (-Pole base) 11 0K0-D (-Pole base) 10 0K0-V (4-Pole base) 17 (-pole base) 0K0-E (4-Pole base) Other -Pole 1-10-6 0K0-E (4-Pole base) Other 4-Pole 1-1-1-1 0K04-SA 1/1/10 0K04-X 1-1-11 0K04-C 1-1-5-5 0K04-A 1-6-1-6-6-11 0K04-T6 (7-Pole base) 1-6-10-6-1-6 0K04-AK (7-Pole base) 0K05-G5 6--10-6 0K05-S 0K0-G (-Pole base) 44 STATES TYPE SJK TEST SWITCHES

FRONT VIEW 5-POLE (CONT.) 6-5-5-5-5-5-6 0K05-N5 Other 5-Pole 1-6-1-6-1-4 0K05-C 1-6-6-10-11 0K05-B6 1-6-6-0K05-J4 6-10-1-10-6 0K05-K 6-1-1-1-1-1-6 0K05-L5 6-/1/1-1-6 0K05-B 6-POLE (ON 7-POLE BASE) ---6 0K06-N4 1-1-1-6 0K06-F 1-10-1-11-6 0K06-T Other 6-Pole 1-1-1-1-1-1-6 0K06-B 1-1-1-1-1-1-6 0K06-V 1y-1y-1y-1y-1y-1y-6 0K06-B 1-1-1-6-5-5-5 0K06-LC -/6-1 0K06-S5 4-6-4-6-4-5-6 6-POLE (CONT.) 0K06-S 9-9-9-9-9-9-6 0K06-P5 11-11-11-6 0K06-Q 10-10-10-6 0K06-R7 1-1-6/1/1 0K06-A 1-1-6/ 0K06-C5 1-1-1-6 0K06-DC 1r-1r-1r-6 0K06-FR 7-POLE (ON 7-POLE BASE, UNLESS OTHERWISE NOTED) 1-10-1-11-1 0K07-A -10-10 0K07-B 1-1-1-1-1-1-1 0K07-S Color Option: 1y-1y-1y-1y-1y-1y-1y 0K07-B 9-9-9-9-9-9-9 0K07-R 9-9-9-4-19 0K07-T Other 7-Pole /1/1/1/10-10 0K07-BP 1e-1b-1g-10eg-10bg 0K07-BQ 1-1-1-10-11 0K07-E 1-1-1-1-11-1 0K07-RA 1/1/1-6-6-6-10-10 0K07-CE (10-Pole base) 1-10-1-10-1 0K07-K /1/10/1/11/1/ 0K07-M /1k/10wg/1b/10gy/1/ 0K07-CC 1-11-1-11-1 0K07-Z 1-1-1-1-1 0K07-D 1-1-1-1-1 0K07-AZ /1/1/1y/1/1 0K07-DY 1-6-1-6-1-6-10-11 0K07-CF (10-Pole base) /1/6-10-6/1/6-10/1/ 0K07-CG 10-Pole base) 1-6-10-6-1-6-11/1/ 0K07-C 10-Pole base) 1-6-1-6-1-6-1/1/ 0K07-CD 10-Pole base) 9-11-9-11-9 0K07-NA 10-11-1-1-1 0K07-G 1-1-1-1 0K07-AX STATES TYPE SJK TEST SWITCHES 45

FRONT VIEW -POLE (ON 10-POLE BASE) 6-1-10-1-1-11-1-6 9-POLE (ON 10-POLE BASE) 1-1-1-1-1-1-6 10-POLE (ON 10-POLE BASE) 1-10-1-10-1-10-1 0K0-B 6-1-1-1-1-1-1-6 0K0-CD 9-9-9-9-6-6-9-9-9-9 0K09-C 1-1-1-6-4-6-4-6-4-5 0K09-D 1-10-1-10-1-10-6 0K10-E Color Options: 1-10bw-1y-10gw-1e-10nw-1w 0K10-BZ 1-10rk-1w-10wb-1g-10ge-1k 0K10-Z5 1-1-1-1-1-1-1 0K0-U9 Color Option: 9r-9r-9r-9r-6-6-9r-9r-9r-9r 0K0-XA Other -Pole 1b/1g/1/4/-6-10-6-11rr 0K0-CF 6-1-1-1-1-1-1-1-1-6 0K0-N 6-1-1-1-1-1-1-1-1-6 0K0-AB 6-1-1-1-1-10-10-6 0K0-PE 6-1-1-1-1-10-11-6 0K0-E 6-1/1/1/1/1-1-6 0K0-B6 6/1/6/1/6-4/1//1/6 0K0-CG 6-1r-6r-9k/1k/1w-9w-5g-1g-6 0K0-P6 6-1-10ek-1y-1w-10gk-1k-6 0K0-ME 6-1-10-10-10-1-6 0K0-F7 6-1-1-1-1-1-1-6 0K0-J 6-9-9-9-9-9-9-9-9-6 0K0-T9 6-9-9-9-4-19-5-6 0K0-TE 6-10-10-10-1-1-6 0K0-V 6-10-10-10-10-6 0K0-K6 6--4-1-1-6 0K0-JE 0K09-K -10-10-10-6 0K09-XU Other 9-Pole 1-1-1-1-1-1-1-1-1-6 0K09-W 1-1-1-1-1-1-1-6 0K09-C7 1-1-1-10-10-10-6 0K09-U 1-1-1-11-11-11-6 0K09-P 1-1-4-6-4-6-4-6-4-5 0K09-F 1-10-10-1-10-1-6 0K09-G 1-11-1-11-1-11-6 0K09-N 1-1-1-1-1-1-6 0K09-H 9-9-9-9-9-9-9-9-9-6 0K09-Q4 9-10-10-10-10-6 0K09-U7 10-10-10-1-1-1-6 0K09-D 10-10-10-10-9-6 0K09-AB 11-9-11-9-11-9-6 0K09-XB 0K10-C 9-9-9-9-4-14-19 0K10-MA 1-1-1-1-1-1-1-1-1-1 0K10-Y Color Options: 1y-1y-1y-1y-1y-1y-1y-1y-1y-1y 0K10-H 1k-1k-1k-1k-1k-1k-1k-1k-1k-1k 0K10-K 1-1-1-1-10-10-10 0K10-BT 1e-1b-1-4-10eg-10bg-10rg 0K10-BV /1/1/1/4-11-11-11 0K10-D7 1-1-10-10-1-1-1-1 0K10-BB 1-6-1-6-1-6-4-4-4-4 0K10-X /1/10/1/10/1/10/1/ 0K10-EM 1-1-1-1-1-1-1 0K10-G /1/1/1/1/1/1/1y/ 0K10-W5 1-1-1-1-1-1-4 0K10-F /1/1/1/1/1/1/4/ 0K10-M ---- 0K10-AA 46 STATES TYPE SJK TEST SWITCHES

FRONT VIEW 10-POLE (CONT.) ----1 0K10-CK 9-9-9-9-9-9-4-19 0K10-M9 9-9-9-9-4-5-5-5-5-5 0K10-BS 9-9-9-9-4-19-19 0K10-G9 9-9-9-4-19-19 0K10-V9 10-10-10-10-10 0K10-M4 1-1-1-1-1-1-4 0K10-BU ELEMENTS FOR CUSTOMIZED SWITCHES NOT LISTED UNDER TYPICAL ARRANGEMENTS 1 1 17 Single-Pole Potential Ganged Double-Pole Potential Ganged Three-Pole Potential 9 Ganged Two-Pole Short- Circuiting Current Assembly 6 10 0 5 Ganged Three-Pole Short- Current Test Jack Short-Circuiting Assembly With Right-Hand Common Bar Right-Hand Current Assembly Consists of Test Jack and Short- Circuiting Current Assemblies Ganged Three-Pole Short- Circuiting Current Assembly, Right Extension 11 19 4 Short-Circuiting Assembly With Left-Hand Common Bar Left-Hand Current Assembly Consists of Test Jack and Short- Circuiting Current Assemblies 6 Blank Space Ganged Three-Pole Short- Circuiting Current Assembly, Left Extension 5 0-Amp Fuse Mounting Clip Left-Hand Through Bar and Three-Pole Short-Circuiting Current Assembly Current Test Jack With Left- Hand Common Bar Right-Hand Through Bar and Three-Pole Short-Circuiting Current Assembly 4 Current Test Jack With Right- Hand Common Bar Through Bar NOTES: 1. Barriers are provided between poles of opposite polarity.. Potential handles are red and current handles are black unless otherwise specified.. Arrange elements left to right, front view. 4. Covers are only available on 4, 7 and 10 pole bases. 5. Element No. 5 accepts standard cartridge fuses rated 600 VAC 0 AMP Fuse dimensions must be 1/" diameter and " in length (Fuses Not Included) DIMENSIONS (IN INCHES) FLUSH MOUNT SWITCH "A #10- TERMINAL STUD 5 15" 4 5" 15" 5" 1 4 4 4 5" 1" B C CUT OUT 4 4 7" DIA BASE DIMENSIONS IN INCHES SIZE BASE DIMENSIONS IN INCHES (POLES) SIZE A B C 7" 7" 5" 4 (POLES) 6 5 5 9" 1" 1" 7 9 7" 1" 19" " 10 1 4 1 1 7 10 9 1 A B C 7" 5" 5 5 9" 1" 6 1" 19" " 11 1 STATES TYPE SJK TEST SWITCHES 47

DIMENSIONS (IN INCHES) 9" 10 9/" 1" 10-POLE BASE 15" 5" FRONT CONNECTED- MOUNTING HOLES 1/4 INCH DIAMETER CLEARANCE (TYPICAL) BACK CONNECTED STUD CLEARANCE HOLES TO BE 11/ INCH DIAMETER (TYPICAL) 7 4 " 4 5/" 5/" 5 5" 15" 5" 7-POLE BASE 15" 5" 4-POLE BASE 9" 1 9/" 1/" 1 " " 1 " 5/" 15" " 1 5" 5" 15" 1 -POLE BASE -POLE BASE 1-POLE BASE 7" (TYP.) #10- TERMINAL STUD 7" (TYP.) #10- TERMINAL STUD 4 4 OPTIONAL COVER 5" FRONT CONNECTED " BACK CONNECTED 10 POLE - 11 7 POLE - 4 POLE - 4 1" 4 STATES TYPE SJK TEST SWITCHES

STATES SJK-RK1 Test Switch ORDERING INFORMATION Part No. RK1-A Yellow Handle RK1-B Red Handle RK1-C Black Handle RK1-D White Handle RK1-E Blue Handle RK1-F Green Handle. Dr. #7 (.01) Center Bore 1/4 Diameter X 1/ DP. ( PLCS.).00..00 1.50.750 1.00.75 STATES TYPE SJK TEST SWITCHES 49