Breath Alcohol Tester

Similar documents
Breath Alcohol Tester

TABLE OF CONTENTS. Introduction

The breath sample was not strong enough to detect a reading. After warm up, please blow strong and steadily into the mouthpiece.

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

Andatech SOBERPOINT 3. Wall Mounted Breathalyser USER S MANUAL

The KAALCPROFCA Personal Breathalyzer is a hand held Professional Alcohol Analyzer. It provides stable, accurate and reliable measuring technology.

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

The KAALCPROFCA Personal Breathalyzer is a hand held Professional Alcohol Analyzer. It provides stable, accurate and reliable measuring technology.

DIGITAL DISPLAY ALCOHOL BREATH TESTER

AT8020. Breath Alcohol Tester. Using manual. Ver:HW

BrAC Audit Lock-1 Instruction User Manual

Accumed BAC-178 Professional Fuel Cell Sensor Alcohol Tester

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

Andatech PRODIGY USER MANUAL

ACE II Basic. Operating manual.

Salt 1 Pocket Salinity Tester Instruction Manual

ALCOSENSE FR9000 INTERLOCK USER GUIDE/MANUAL

EC20 Pocket Conductivity Tester Instruction Manual

MoistureMatch A next generation grain tester

Intelligent NiMH/NiCd/Li-ion Charger TN456

Errors in Current Alcohol Breath Analysis

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

Digital Formaldehyde Meter

Compact Scales. Software Revision V1.25 & above

D Dräger Interlock 7000 User Guide Victoria s Alcohol Interlock Program

Owner s Manual Q3 Innovations, LLC v070108

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

2/10/2016. Why Ignition Interlock? The Nuts & Bolts of Ignition Interlock. Separating Drinking from Driving

Dräger Alcotest 6810 for DOT

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Marin Control Digital

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Grain Moisture Meter. Operators manual

Intelligent Battery Charger

Flue Gas Analyzer IMR 1100F

APPENDIX B ALCOHOL SAMPLE COLLECTION AND TESTING PROCEDURES

Electrostatic Fieldmeter

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

User's Guide. CO 2 Meter. Model CO250

PH20 Value ph Tester Instruction Manual

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

WARRANTY...1 NOTICE INTRODUCTION USE...8

BM16LP. Thanks for your purchasing the cell monitor for your vehicle.

Atlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY

Intelligent Electronic Safe

AMS 2000 USER GUIDE GUARDIAN INTERLOCK RESPONSIBLE DRIVER PROGRAM. GuardianInterlock.com Ensuring Safety For Over 30 Years.

EAGL 1-Touch Laser Level

MS-4200/4201/4202/4202L USER MANUAL

MOISTURE METER 2155 OPERATION INSTRUCTIONS VERSION 1.0

All other marks are trademarks or registered trademarks of their respective holders.

BMS SV 24S for 2S-24S LiPo, LiFe & LiTO&others Low power consumption High accuracy 2.8 TFT LCD display Programmable

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Guardian AMS2000 Operating Guide KS

EC1 Pocket Conductivity Tester Instruction Manual

TDSscan10M Pocket TDS Tester Instruction Manual

IAQ-CALC TM Indoor Air Quality Meter

IAQ-CALC TM Indoor Air Quality Meter

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Dawson DSM170 Multi-Function Moisture Meter User s Manual

PLS SLD. Laser Detector PACIFIC LASER SYSTEMS. For use with your PLS pulsed laser alignment tool. The Professional Standard

TMD90A Dual Input Digital Thermometer

Indoor Air Quality Meter

Crane Scale. NC Series OWNER S MANUAL

KIT CONSISTS OF: FEATURES. S-Digit mini

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

HIGH VOLTAGE PROVING UNIT

OPERATING INSTRUCTION

User Guide. Model Insulation Tester / Megohmmeter. Introduction

ORPscan20 Pocket ORP Tester Instruction Manual

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Power Inverter 400 MW Owner s Manual

BATTERY CHARGER RS-1000 Instruction Manual

Contents. 1. Warnings and Cautions Warnings Cautions... 3

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Dräger INTERLOCK XT User Manual Version 3.2

FAQs for the Draeger Interlock 7000

Digital/Analog Megohmmeter Model 1026 USER MANUAL

GRAVITY MEASUREMENT, INC.

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

230VAC Power Inverter 400W Owner s Manual

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

ECscan20 Pocket Conductivity Tester Instruction Manual

PH60 Series Premium ph Testers

OPERATING INSTRUCTIONS

AXD 530 MicroManometer

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

PHscan10S Pocket ph Tester Instruction Manual

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

709 Rev. 6.x Analyzers

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Jumpbox Model SP-12V1500-JB1

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Water Level Meter + Temperature

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

Transcription:

Breath Alcohol Tester Advanced fuel cell sensor Personal & professional use alcohol tester DA-8000 Instruction Manual DA-8000 Fuel cell ( Electrochemical) accuracy 4-digit LCD display with a backlit User adjustable blow time / Measuring unit / beep alarm Comes with a hard shell carrying case Please read the user's manual carefully before use.

DA-8000 Introduction Thank you for your purchasing our product. Alcofind DA-8000 is a breathalyzer with a fuel cell sensor. It offers enhanced accuracy and it's easy to carry with you. It's the entry-level unit for the professional use such as screening, clinics, military and many other segments which require high-accuracy and high-reliability. Contents Name of Each Part Digital Breathalyzer Alcofind DA-8000 2 (two) AA size Batteries 6 (six) Mouthpieces Hard shell Carrying Case User's Manual Mouthpiece Warning lamp Display window START (Ready to test) Outlet MODE Product Specifications Indication of B.A.C. Accuracy Warm up time Response time Sensor Power supply Battery Life Dimensions Weight Calibration Operating temperature 0.00 ~ 0.50%BAC 0.00 ~ 5.00 0.00 ~ 2.50mg/l +/- 0.005%BAC at 0.1%BAC at 25 C +/- 0.05 at 1.0 at 25 C +/- 0.025mg/l at 0.50mg/l at 25 C Within 18 seconds at 0.05%BAC Within 10 seconds at 0.05%BAC Professional Fuel cell sensor 2 (two) AA size alkaline batteries Approx. 1500 tests 58mm x 123mm x 24mm 131g including batteries every 12 months or after 500 tests 0 ~ 40 C The specifications are subject to change without prior notice for functional improvements.

How To Use CAUTION : Please do not blow hard, the sensor can be damaged by a small amount of saliva. 1. Initial Use Press down the battery cover of the unit to open it and install two AA size 1.5 V alkalin e batteri es paying attention to the battery polarity. Close the battery cover and insert the mouthpiece to the slot. 2. How to test Breath Alcohol Concentration b) Press the start button again and it automatically begins a countdown. c) When the countdown reaches "0" (zero), then blow through the mouthpiece for more than 4~5 seconds till there is a double deep sound. d) Once the sensor has analyzed the breath sample, it displays the estimated Blood Alcohol Concentration. (When the unit operates normally) Breath sampling Breath Analyzing Indication of test result Error Messages If the user does not blow a sufficient breath sample, the LCD will display "FLO". Press START to restart the countdown cycle and retest. If there is no breath sample blown within 15 seconds, the LCD will display "OUT". Press START to restart the countdown cycle and retest.

If the unit is powered on outside of the acceptable temperature range (0~40 C) the unit will display Out C and testing cannot be performed. If the battery is empty, the LCD will display "BAt" Then install two new alkaline AA batteries. 3. How to adjust measurement "unit" b) Press and hold mode button for more than 5 seconds till the unit c) By pressing the start button, you can adjust measurement unit. 4. How to adjust "beep"(audible warning) b) Press and hold the mode button for more than 5 seconds till the unit If you press the mode button again shortly, the unit c) By pressing the start button, you can adjust beep level. 5. How to adjust "blow time" b) Press and hold the mode button for more than 5 seconds till the unit Press mode button shortly till the unit c) By pressing the start button, you can adjust blow time.

6. How to adjust "flow detecting setting" performed for a second and then displays b) Press and hold the mode button for more than 5 seconds till the unit Press mode button shortly till the unit displays c) You can adjust flow detecting setting by pressing start button. d) 3 kinds of settings are available - standard, user, low Flow Detection Settings Use this option to adjust how hard a user is required to blow. Press Start to change the settings. Standard level flow detection This is the default setting for the unit. User activated test mode Press Start again to change to the USER activated test mode. When testing in this mode the operator must press Start to take a breath sample during blowing and to perform a test. Low level flow detection Press Start again to change to the low level flow setting. This level requires a less forceful breath by the user. This setting is helpful for subjects with decreased lung capacity and can also be helpful if a user has received the FLo error result.

Warnings Wait at least 20 minutes after drinking alcohol to test blood alcohol concentration. For protection of the sensor, avoid direct ray of light, extreme temperature, humid place, keep the device in a well ventilated place and keep out of reach of children. When not used for a long time, keep the device after taking out the batteries. In case of reuse after long-term storage, there might be high tolerance of test result for about first 3 tests. We recommend you to replace the disposable mouthpiece for sanitary purpose. Do NOT use the device as a tool to drink and drive. The manufacturer and seller will not take any legal responsibility for the measured test value. Shocking during the test might cause wrong test result. When the battery icon is flickering, then use new batteries for the precise test. In case the measured value is higher than 0.1%BAC and you try again without interval, then warm up time might be delayed. Test under loud noise would be the reason of malfunction. In this case, try again in a quiet place. If you perform testing at 10 C or below, the test result might not be accurate. In case some amount of moisture and/or saliva enters into the breathalyzer, it might cause malfunction of the device. In this case please wait at least 1~2 hours before using, until the moisture and/or saliva dried up. Warranty Card Product Purchasing Date Warranty Period (DD-MM-YY) Digital Breathalyzer Alcofind DA-8000 Seller Shop name Owner name The manufacturer warrants the product to be free from defects in workmanship or material (excluding calibration) under normal use either for 1(one) year from date of purchase. The manufacturer's obligation under this warranty is limited to replacing, adjusting or repairing the unit at manufacturer's option, if returned along with proof of purchase. For any defects due to natural disaster or customer' s negligence, misuse, reconstruction and repair by unauthorized person, reasonable cost shall be charged for repair or part replacement. Customer Service For any question, after sales service, product calibration or purchasing mouthpiece, please get in contact with the nearest distributor in your country. Manufacturer Distributor