Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Supplemental Installation Instructions -- August 2016

Supplemental Installation Instructions -- August 2016

Owner s Information Manual

Installation Instructions

Installation Instructions

Installation Instructions

Electrical Data Supplement

Electrical Data Supplement

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

Electrical Data Supplement

Installation Instructions

Electrical Data Supplement

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Wiring Diagrams (Including Accessories) (50/60 Hz)

Installation and Start Up Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S S S Durability. DuraGuardt protection package: Warranty Single-Phase.

Product Data. 24ABR3 BasetSeries 13 Air Conditioner Sizes 18 to /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Installation Instructions

Installation Instructions

Product Data. 24ABA4 BasetSeries 14 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Installation Instructions

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S S S Durability A WeatherArmort protection package: Warranty Single-Phase

TSA6. Product Specifications. SmartComfort TXC 5600

IMPORTANT ATTENTION INSTALLERS:

Product Data. 25HBA4 BasetSeries 14 Heat Pump with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Electronically Commutated Motor Wiring Manual

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

Installation and Start-Up Instructions

Technical Manual. DLM Module. This manual should remain with the unit.

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

Owner's/Installation Manual

TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N4A3, 3 Phase

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

SERVICE INSTRUCTIONS

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A0, 3-Phase

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

N4A6. Product Specifications

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

TECHNICAL SUPPORT MANUAL Split System Heat Pump N2H3**C (Coastal)

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

CSA6. Product Specifications. SoftSound SXC 2600

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

INSTRUCTIONS INSTALLATION. Read these instructions carefully. These instructions MUST stay with this product.

Product Data PA16NA FEATURES AND BENEFITS. 16 SEER Split System Air Conditioner with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

TECHNICAL SUPPORT MANUAL Split System Air Conditioner (C,H,T)4A3

Installation Instructions

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A3, 3-Phase

Models: WA182, WA242. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Galaxy VM. Battery Breaker Box Installation 09/

Wiring Diagrams DIAGRAM INDEX

Installation Manual. English. French

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N

Product Data. 24APA7 Performancet Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

Product Data PH13NB PH13PB FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Transformer Installation, Operation, and Maintenance Manual

Transcription:

KALA0601AAA KALA0701AAA MotorMasterR Low Ambient Controller for Residential plit ystem Applications Installation Instructions Fig. 1 - MotorMasterr Low Ambient Controller A93157 NOTE: Read the entire instruction manual before starting the installation. AFETY CONIDERATION Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory -authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit.. Consult local building codes and current editions of the National Electrical Code ( NEC ) NFPA 70. In Canada, refer to current editions of the Canadian electrical code CA 22.1. Recognize safety information. This is the safety -alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety -alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestionswhich will result in enhanced installation, reliability, or operation.! WARNING ELECTRICAL HOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position and install a lockout tag. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label.! CAUTION CUT HAZARD Failure to follow this caution may result in personal injury. heet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. INTRODUCTION These instructions cover installation of MotorMasterR Part No. KALA0601AAA and KALA0701AAA on all residential single-speed air conditioners and heat pumps. The device is designed to control outdoor fan motor speed under low outdoor temperature conditions. A fan motor with ball bearings is required. The control is available in two models. Part No. KALA0601AAA is rated for 208/230-1 -60 which can be used on units that are 208/230 single or 3 phase and part no. KALA0701AAA is rated for 460-1 -60 which can be used on units that are 460 3 phase. Other accessories may be required. Refer to the Required Unit Changes section of this document for details.

DECRIPTION AND UAGE The MotorMasterR is a fan speed control device activated by a temperature sensor. It is specifically designed to control condenser fan motor speed in response to the saturated condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20_F (-28.9_C), it maintains condensing temperature at 100_F ± 10_F. (ee Fig. 1.) The mounting control consists of a solid -state circuit on a printed circuit board in an aluminum extrusion, and a sensor assembly to be mounted to a return bend on the unit s condenser coil. A wire from the sensor is connected to the circuit board in the control box. Parts necessary for mounting control and sensor assembly are included in the kit. Either assembly can be replaced independently of the other. If any damage to the printed circuit board or components is observed when unpacking control assembly, return for replacement. The MotorMasterR maintains proper condensing temperature at any ambient temperature down to -20_F (-28.9_C). No field adjustments or calibrations are required. The following must be observed: If special fan motors or other accessories are required, install where necessary. Measure unit power supply voltage. It must meet minimum voltage specified on unit rating plate and match voltage rating of MotorMasterR. Make sure all units are modified for winter start control when needed. Check that control location is as specified. Check that sensor location is as specified. Make sure that sensor wiring routing is as specified. Make sure wind baffles are installed only if required. For heat pump units, make sure isolation relay is available.! INTALLATION CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in unit damage. Exercise extreme caution when drilling holes. Do not puncture coil and/or tubing. PROCEDURE 1 MOUNTING CONTROL AEMBLY 1. Make sure all power to unit is turned off! WARNING ELECTRICAL HOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position and install a lockout tag. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label. 2. Determine location for control assembly. (ee Fig. 2.) Remove template from back of this instruction and tape to panel. Drill pilot holes as indicated. When mounting to service panel, drill two holes, 5/32 -in. (0.156 in.) diameter, 1 in. away from panel edge as shown. (ee Fig. 2.) 3. To ensure electrical ground with condensing unit, insert star lock washers under head of screws. Fasten control assembly to unit with four No. 10 sheet metal screws provided. If wind baffles are used, ensure control has a continuous ground path to equipment ground. If control is mounted independent of unit, ensure an adequate ground path is maintained. All wiring must conform to NEC and/or local code. NOTE: When properly positioned (mounted vertically with leads protruding from bottom of control), control is weather tight. PROCEDURE 2 MOUNTING ENOR Mount sensor on a specified condenser coil return bend as shown in Fig. 3. IMPORTANT: The sensor assembly is delicate. Handle with care. 4. Route sensor wire through bottom knockout on service panel and over to outside row of coil (left side), taking care not to disturb tubing. 5. ecure sensor on coil return bend with the No. 4-40 screw and nut supplied with kit as shown in Fig. 4. 6. Bind unused wire and secure it near sensor or next to control. 7. Protect sensor wire from physical damage or wind movement where necessary. 2

Bryant --- Legacy --- RNC / Legacy Models Bryant --- Legacy --- RNC / Legacy Models Carrier --- Base / Comfort eries Models Carrier --- Base / Comfort eries Models Fig. 2 - Control Mounting A06439 3

TOP OF COIL VAPOR IN ENOR LOCATION LIQUID OUT or JUMPER TUBE Fig. 3 - ensor Location on Return End of Coil 4

No. 4 --- 40 crew Coil Return Bend ensor Clinch Nut No. 4---40 Nut Fig. 4 - MotorMasterr ensor A93163 REQUIRED UNIT CHANGE This section explains the changes required to equipment when MotorMasterR is applied. Use this section in conjunction with appropriate wind baffle figures and tables at rear of instruction. A ball bearing fan motor is required with this control. PROCEDURE 1 CONDENING UNIT A. Outdoor Fan Motor Consult presale literature for outdoor fan motor change. B. Crankcase Heater Required on all applications where MotorMasterR is used. If not already installed, consult presale literature for required crankcase heater kit. C. Hard tart Assist Kit (Capacitor and Relay) Required on all single-phase applications where MotorMasterR is used. If not already installed, consult presale literature for required start kit. D. Winter tart Control Must be used where low evaporator temperatures or nuisance tripping of low -pressure switch may be encountered. Winter start control Part No. KAAW0101AAA must be wired in parallel with low -pressure switch. (ee Fig. 5.) This allows a delay of approximately 3 minutes before low -pressure switch becomes a part of control circuit. NOTE: It is REQUIRED that evaporator freeze thermostat Part No. KAAFT0101AAA be attached to vapor tube near evaporator coil to prevent coil freezing. Wire thermostat in series with 24 -v contactor coil. (ee Fig. 6.) E. Wind Baffles Use only in installations where high winds are prevalent to prevent cross currents from causing abnormal control operation. For construction, refer to appropriate wind baffle figures and tables at rear of this instruction. NOTE: When wind baffles are used, raising unit off of mounting pad with 4 -in. support feet or unit risers is REQUIRED. This provides better airflow for moderate and high ambient temperatures. F. Wiring MotorMasterR must be wired in series with fan motor. (ee Fig. 7.) Power wiring must comply with all local codes and NEC requirements. INDOOR THERMOTAT Y FROM CONTACTOR TDR LP C TDR T T LP C LOW -PREURE WITCH CONTACTOR COIL TIME DELAY RELAY TIME DELAY RELAY COIL FACTORY WIRING FIELD WIRING Fig. 5 - Winter tart Control EVAPORATOR FREEZE THERMOTAT C A93165 OUTDOOR CONTACTOR Fig. 6 - Evaporator Freeze Thermostat Wiring CAP BRN LOW -AMBIENT CONTROL BRN ENOR PHAE MAIN MOTOR UITABLE FOR UE WITH MOTOR MATER CONTROLLER Fig. 7 - Power Wiring for 208 -v, 230 -v, and 460 -v Condensing Units A97511 A03225 5

PROCEDURE 2 HEAT PUMP A. Outdoor Fan Motor Consult presale literature for outdoor fan motor change. B. Crankcase Heater Required on all applications where MotorMasterR is used. If not already installed, consult presale literature for required crankcase heater. C. Hard tart Assist Kit (Capacitor and Relay) Required on all single-phase applications where MotorMasterR is used. If not already installed, consult presale literature for required accessory start kit. NOTE: It is REQUIRED that evaporator freeze thermostat Part No. KAAFT0101AAA be applied to the evaporator coil to prevent coil freezing. Wire thermostat in series with 24 -v contactor coil. (ee Fig. 6.) D. Wind Baffles Use only in installations where high winds are prevalent to prevent cross currents from causing abnormal control operation. For construction, refer to appropriate wind baffle figures and tables at rear of instruction NOTE: When wind baffles are used, raising unit off of mounting pad with 4 -in. support feet or unit risers is REQUIRED. This provides better airflow for moderate and high ambient temperatures. E. Isolation Relay (Heat Pump ONLY) Mount isolation relay in unit control box and wire into power and control circuits. This relay switches MotorMasterR out of outdoor fan motor circuit when heat pump switches to heating cycle. Relay Part No. KHAIR0101AAA is REQUIRED for use with 208/230 -v and 460 -v systems. Note the following: 1. Normally closed relay contacts must be in parallel with MotorMasterR asshowninfig.8. 2. Normally open relay contacts must be in series with Motor- MasterR asshowninfig.8. 3. Isolation relay coil must be connected across circuits O and C on defrost board. F. Wiring MotorMasterR must be wired in series with fan motor. (ee Fig. 8.) Power wiring must comply with all local codes and NEC requirements. CONTACTOR CONTACTOR OF1 OF2 DEFROT BOARD 1 IOLATION RELAY 2 3 MOTOR MATER CONTROL CAPACITOR BLU RED BRN FAN MOTOR ENOR DEFROT BOARD 1 OFR 3 1 2 CAPACITOR IOLATION RELAY 3 MOTOR MATER CONTROL BLU RED BRN ENOR A93168 208/230 -v 460 -v Fig. 8 - Power Wiring for 208/230 -v and 460 -v Heat Pump Units A93156 6

TART -UP To start up units equipped with accessory MotorMasterR: 1. Turn unit power on. 2. et thermostat below room temperature. 3. Wait at least 5 minutes if unit is equipped with a delay circuit. Fan motor starts 15 sec before compressor when standard delay circuits are used and may: a. Not operate when ambient is below 50_F (10_C). b. Run at slow speed when ambient is between 70_F (21.1_C) and 80_F (26.7_C). c. Run at or near full speed when ambient is above 80_F (26.7_C). 4. When compressor starts, fan speed modulates smoothly to proper controlled speed based on saturated condensing temperature. After system has run and settled out, saturation temperature is approximately 100_F ± 10_F, if the outdoor ambient is below 60_F (15.6 (26.7_C)C). ERVICE No field repairs are to be made on this kit. If either the sensor or the control fails, it should be replaced. If fan motor does not turn, check control as follows: 1. Check power to condensing unit. 2. Check for voltage across fan motor relay contacts. 3. Check for loose sensor wire connections in MotorMasterR splice compartment. 4. Bypass MotorMasterR by connecting black wire from unit contactor directly to black fan motor lead. (ee Fig. 7 or 8 and unit wiring label.) a. If fan does not turn, make sure motor is wired into circuit properly and run capacitor is not defective. Replace motor or capacitor if defective. b. If fan motor runs, make sure that motor was wired in series with MotorMasterR. 5. If motor runs when connected to single-phase voltage supply, but does not run when connected in series with Motor- MasterR, check sensor as follows: a. Check temperature of return bend near sensor with an electronic thermometer. b. Disconnect both sensor leads. c. Check sensor resistance with an ohmmeter and compare resistance/temperature readings to those in Fig. 9. d. If sensor is within tolerance shown in Fig. 9, replace MotorMasterR. If sensor is NOT within tolerance shown in Fig. 9, replace sensor. 10,000 9000 8000 REITANCE IN OHM 7000 6000 5000 4000 + 10% NOMINAL - 10% 3000 2000 1000 50 (10) 60 (15.5) 70 (21.1) 80 (26.7) 90 (32.2) 100 (37.8) 110 (43.3) 120 (48.9) 130 (54.4) TEMPERATURE IN F ( C) Fig. 9 - ensor Resistance/Temperature Chart A93173 7

Fig. 10 - Base / Mid -Tier Baffle Assembly Table 1 Wind Baffle Dimensions for Entry and Mid---Tier Units (in.) UNIT IZE AA UNIT HEIGHT A B C --- 1 C --- 2 C --- 3 D 25 20---3/8 10---1/16 28---7/16 23---13/16 11---3/4 31---13/16 27---3/16 13---1/2 mall 25---3/4 35---1/4 30---5/8 15---3/16 3---15/16 10---7/8 6 --- 1/8 41---7/8 38---5/8 34 16---7/8 42 37---3/8 18---9/16 45---7/16 40---13/16 20---1/4 25---1/2 20---3/8 10---1/16 28---15/16 23---13/16 11---3/4 32---5/16 27---3/16 13---1/2 Medium 31---1/4 35---3/4 30---5/8 15---3/16 9 --- 3/8 16---5/16 11---9/16 47---3/8 39---1/8 34 16---7/8 42---1/2 37---3/8 18---9/16 45---15/16 40---13/16 20---1/4 25---1/2 20---3/8 10---1/16 28---15/16 23---13/16 11---3/4 32---5/16 27---3/16 13---1/2 Large 35 35---3/4 30---5/8 15---3/16 13---3/16 20---1/8 15---3/8 51---1/8 39---1/8 34 16---7/8 42---1/2 37---3/8 18---9/16 45---15/16 40---13/16 20---1/4 A06450 8

9

Copyright 2010 CAC / BDP 7310 W. Morris t. Indianapolis, IN 46231 Printed in U..A. Edition Date: 07/10 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 Catalog No: IIK -KALA-03 Replaces: AG -KALA -02