PACIFIC SHORING, LLC ALUMINUM SHORING PRODUCTS ALUMINUM PANEL SHIELDS APS-HORIZONTAL-RED/YELLOW. TABULATED DATA Effective March 20, 2015

Similar documents
Build-A-Box. Modular Trench Shielding System. Tabulated Data Effective January 4, Revised: April 21, with CHANGE THREE

Build-A-Box Modular Trench Shielding System

Hydraulic Shoring Product Guide

Hydraulic Shoring Product Guide

Optimum Versatility Aluminum Shields

TRENCH SHIELDING AND SHORING

TRENCH SHIELDING AND SHORING

TRENCH SHIELDING AND SHORING

PRO-BRACE HYDRAULIC FRAME

AMERICA S TRENCH BOX BUILDER Aluminum Trench Shield Product Application Guide

AMERICA S TRENCH BOX BUILDER Aluminum Trench Shield Product Application Guide

Steel Products. 8M Series

SERVICE - SERVICE - SERVICE!

Trench Shielding Product Guide & Custom Shoring Services

Users should note that settlement of the reinstated ground and ground next to the Aluminium Trench Shield is likely to occur after backfilling.

INSTALLATION OPERATING SERVICE AND SAFETY INSTRUCTIONS

AMERICA S TRENCH BOX BUILDER Steel Trench Shield Product Application Guide

Table of Contents General Information Safety Message Classifi cation...2 Safety Notes...3 Terminology...4 Coupler Lifting Lug...

SITE ACCESS EQUIPMENT

3 in. Steel Single and Double Wall Municipal Shields XLSM3. XLSM3 Sidewalls 3 in. Steel Single Wall Municipal Trench Shield

MS2200, MS2500, and MS3000 Suspension Installation Manual ON/OFF HIGHWAY SUSPENSION SYSTEM

Airshore Rescue Tools

Excavation worker killed by flying rigging when hook fails

SECTION 14: AERIAL LIFT PROGRAM

City of New Haven. 101 FRONT STREET PO BOX 236 NEW HAVEN, MO Phone * * Fax

Elongated Tube. Series. offs. Unique Router Design. on Outer Skin and. Page 4

Powered Industrial Trucks

OSHA Update. Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926)

Owner s Manual. Rigid Mount Weld-on Drawbars. XL-DB20016UM-en-US Rev

Installation Instructions

Depth of Bury Tables 9B-5. A. General. B. Rigid Pipe Assumptions. Design Manual Chapter 9 - Utilities 9B - Trench Design

Ho-Pac. Allied s hydraulic vibratory compactor/driver

In This Document MODULE DESCRIPTION This module provides information on the safety concerns and

UNIVERSITY OF TOLEDO

1. Cranes. 3. Hazardous Chemicals. 4. Signs. 2. Trenching and Excavations

MALAYSIAN STANDARD. Earthworks - Code of practice. NOTE. This Malaysian Standard has been reviewed and confirmed as being current.

BECAUSE YOU NEVER GET A SECOND CHANCE N. Post Road Shelby, NC Phone Number for International Callers:

Airworthiness Directive Schedule

America s Largest Importer/Wholesaler of Wire Rope, Chain and Fittings!

Bobcat Backhoe Attachments

ELIMINATOR Dump bodies

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE GENERAL INDUSTRY SAFETY AND HEALTH STANDARD

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

A. Employees It is each employee s responsibility to inspect ladders for defects before each use.

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY AND HEALTH STANDARD. Filed with the secretary of state on

Safety. Chapter 13 SAFETY PROGRAM GENERAL SAFETY RULES

STEEL SIDE PANEL KIT. Model (FOR USE WITH MODEL FOLDABLE UTILITY TRAILER)

ASSEMBLY GUIDE CONCERT SERIES 700-HP RIGGING GRID AND ACCESSORIES

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes

Health, Safety, Security and Environment

Material Handling - Cranes, Hoists, Slings, Chain Falls, and Ratchet Hoists

SHOP RIGGING & OVERHEAD HOIST SAFETY PROGRAM

ELIMINATOR LP DUMP BODIES & HR SERIES HOISTS

Cranes. OSHA Office of Training & Education 1

Safe use of portable ladders

IROn PIPe. McWane DUcTILe

LIFTING RIGGING SAFETY ROAD PLATE LIFTER. Heavy duty trench plate lifting made safer.

Support Equipment. In This Section Mobile Ingredient Bins H Kettle Drainer H Rack/Tray Carts H

Lee County DOT Traffic Section Design Standard for Sign Installation

CRANE & HOIST SAFETY PROGRAM

Attachments For Compact Tractors with Universal Skid-Steer Hitch

BUCKET TRUCK SAFETY EQUIPMENT

MODEL LR-2066 & LR-2866A HOIST INSTALLATION AND OPERATION MANUAL

COLD AIR SYSTEM. Installation Instructions for: Part Number Mazda RX-8 Instructions

Ho-Pac. Allied s hydraulic vibratory compactor/driver

Single slide rail system, parallel shoring, EG PV

WELDING FUME EXHAUSTERS & ARMS

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

FULL-LINE PRODUCT BROCHURE

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

INTERMODAL INSPECTION PROGRAM. J.S. Blake: President N. Schuyler: Vice President

Health & Safety Policy and Procedures Manual SECTION 15 LADDERS

Septic Tanks. Effluent Screen Cleaning. Effluent Screens. Surveying Abbreviations. Installation Keys. Septic Tanks, Holding Tanks & Pump Tanks

Hydraulic power is the key to the utility of many excavators.

LIME PLANT AREA 5 MAINTENANCE AND SHUT-DOWN TASK

LSU University Safety Manual Section IV, Part C Stairs and Ladders. C. Stairs & Ladders

PURPOSE... 1 II. SCOPE... 2 III. REFERENCES... 2 IV. RESPONSIBILITIES...

Newport News Shipbuilding Contractor Environmental, Health and Safety Resource Manual Cranes

Bill of Materials: Please take time to read and understand these installation instructions.

HR-520 HOIST. Installation & Operation Manual. To Be Filled In By Installer. Pump Installation And Operation Manual#: In Service Date: Dealer:

Document Number: HSE May 1, 2014 LADDERS. Author: A Holland. Rev Date Rev # Description Revised By 05/01/14 1 Reformat A.

Operating Instructions & Parts Manual. Model HW93300 shown

Evaluation Report 291

SL210/SL212. (500 Series) SL210 Fixed Pad Capacity 9,000 lbs. and 10,000 lbs. SL210 Capacity 10,000 lbs. SL212 Capacity 12,000 lbs.

READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS PRIOR TO INSTALLATION OF SYSTEM AND OPERATION OF VEHICLE.

Fabricated from grade S x400 steel box section the extensions are quickly assembled into the required

New Bremen, Ohio USA 2004 PF14387-WEB Rev. 6/06 Printed in U.S.A.

IHC & IHC R compactors

Reeves Texas Hold um Fall Protection Trailer OPERATION AND SAFETY INSTRUCTIONS

AURELIA LTD A59 EXCAVATOR 360 ABOVE 10 TONNES INC LIFTING TECHNICAL TEST THEORY CPCS Issue 09-Jul-2012

Appendix E Rollover Protection Table of Contents

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

APPENDIX A Basis of Design and Design Criteria Memorandum

BOGERT HMMWV LIFTING JACK KIT PART NR: 30M-HVBMI NSN:

2002 Chrysler PT Cruiser

Panther Rhino Tear-Off Machine Instruction Manual

HR-540/HR-550 HOIST Installation & Operation Manual

MGF TECHNICAL FILE TRENCH SHEETS. Description. Product Notes.

OPERATOR PROTECTIVE EQUIPMENT. Owner s Responsibility

January 30, Ms. Safety Director Sample Medical Corp. PO Box X Somewhere, CT. Re: NFPA 70E Hazard Assessment. Date of Visit.

Transcription:

1 APS-HORIZONTAL-RED/YELLOW Effective March 20, 2015 PSH 265 Roberts Avenue Santa Rosa, Ca. 95407 (707) 575-9014 Construction Engineering Resource 1837 Wright Street Santa Rosa, Ca. 95404 jmtengr2@aol.com (707) 484-4704

2 Contents Description... 2 General Information for use of Pacific Shoring Aluminum Panel Shields ()... 3 Classification of Soil Types... 4 APS CASE 1-1 Standard APS Shield... 5 APS CASE 1-2 Standard APS Shield w/ End Sheeting... 6 APS CASE 1-3 Standard APS Shield w/ End Panel... 7 APS CASE 1-4 Standard APS Shield w/ 4 Stacker Shield... 8 APS CASE 2-1 High Clearance APS Shield... 9 APS CASE 2-2 HC - APS w/ Horizontal Power Struts & End Sheeting... 10 APS CASE 3-1 High Clearance APS Shield w/ Corner Posts & Panels... 11 Aluminum Panel Shields Notes... 12 Aluminum Panel Shields () -Table 4-Shield Weights... 13 Aluminum Panel Shield Installation and Removal... 14 Safe Handling and Use of Aluminum Panel Shields... 14 Description The Pacific Shoring Aluminum Panel Shields with Horizontal wall panels, (APS-H-Red/Yellow) are lightweight smooth wall shoring shields. They are easily handled with a backhoe or light excavator. These shields allow a 3-5 ft pipe clearance when the box is set at the bottom of the trench and 5-7 ft clearance when the shield is set 2 ft off the bottom. APS-H-Red/Yellow shields can be used with pinned struts with an allowable trench width to 12 ft., pinned struts with end loading to an allowable trench width to 8 ft, and hydraulic struts to an allowable width of 8 ft. This shoring system is generally used in light utility work, water systems, gas and electrical duct bank installations. The optimum range of depth is 8 ft to 12 ft. APS-H-Red/Yellow shields can be used with wheel kits.

3 General Information for use of Pacific Shoring Aluminum Panel Shields () 1. The Aluminum Panel Shields (APS-H-Red/Yellow) tabulated data presented here is based on requirements of Federal OSHA 29CFR, Part 1926, Subpart P-Excavations, and Trenches 1926.652(c)(2)-Option (2) - Designs Using Manufacturer's Tabulated Data. 1926.652(c)(2)(i) -Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data shall be in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer. All provisions of Subpart P apply when utilizing this tabulated data. The contractor s competent person shall use this data to select allowable trench depth, box wall, strut configuration and end condition. The competent person utilizing this tabulated data shall be experienced and knowledgeable of all requirements of Subpart P, and trained in the use and safety procedures for shoring shield applications. 2. Use of this tabulated data is dependent on first classifying the soil in accordance with OSHA Appendix A, Soil Classification. Classification shall be just prior to installing the shoring shield. Soil conditions may change at a later date and require revaluation of the strength and allowable depth. 3. Aluminum Panel Shields (APS-H-Red/Yellow) is tabulated based on the effect of a 20,000 lb surcharge load set back 2 ft from the edge of the trench and the equivalent weight effect of the OSHA soil type, see classification of soil types, 2.2. 4. The allowable depth given in Tables 1, 2, and 3 governs the use of Pacific Shoring Aluminum Panel Shields (APS-H-Red/Yellow). This tabulated data applies to aluminum panel shields manufactured by Pacific Shoring, LLC. 5. Any alterations to the shields or variance from this tabulated data shall be indicated in a site-specific plan prepared and approved by a registered engineer. 6. Faces of excavations shall be vertical and the shoring walls shall be within 12 inches of the excavation wall for static applications. For hydraulic applications fill all voids between shield panel and excavation to ensure arching occurs. 7. Aluminum Panel Shields (APS-H-Red/Yellow) may be stacked or longitudinally connected. Provided they are pinned together. 8. Aluminum Panel Shields (APS-H-Red/Yellow) shall be installed and removed from outside the trench, see installation and removal procedure. 9. The competent person shall continually monitor the shored excavation for changed conditions such as water seepage, soil movement cracks at the surface, sloughing or raveling, proper surcharge load weight less than 20,000 lbs and setback a minimum of 2 ft that may damage the shields. 10. Workers shall always enter, exit, and work inside the shored area of the trench. 11. Aluminum Panel Shields (APS-H-Red/Yellow) may be set a maximum of 2 ft from the bottom of the excavation. The trench depth is the full distance to the bottom of the excavation. 12. Aluminum Panel Shields (APS-H-Red/Yellow) may be used with wheel kits.

4 Classification of Soil Types 1. Soil classification shall be in accordance with OSHA Appendix A and classified just prior to installing hydraulic vertical shores. Soil conditions may change at a later date and require hydraulic vertical shores to be reset at a different spacing. 2. The equivalent weight of OSHA soil types* is assumed to be as follows: OSHA Type A Soil 25 PSF per ft of depth OSHA Type B Soil 45 PSF per ft of depth Type C-60 Soil 60 PSF per ft of depth** OSHA Type C Soil 80 PSF per ft of depth * These equivalent weights were adapted from OSHA 1926 Subpart P App C, Timber Shoring for Trenches, Tables C-1.1, C-1.2, and C-1.3 ** Type C-60 soil is not identified or classified in OSHA Appendix A 3. Type C-60 soil is soil that does not qualify as OSHA Type A, or Type B, can be cut with vertical walls and will stand up long enough to safely insert and pressurize the hydraulic shore. 4. Aluminum Panel Shields () may be used in C-80 soil provided they are dug into the excavation and not driven into the soil. 5. In C80 soil, it is recommended that this equipment be utilized in site-specific plans designed by a registered civil engineer.

5 APS CASE 1-1 Standard APS Shield Table 1-1 CAPACITY AND ALLOWABLE DEPTH FOR SHIELD HEIGHT 4 FT, 6 FT, 8 FT, 10FT SHIELD HEIGHT Vertical Pipe Clearance Spreader Spacing Top Spreader Location Shield Allowable Depth Capacity Allowable Length Trench 4 FT 6 FT 8 FT 10 FT 4 FT 6 FT 8 FT 10 ft 4 FT 6 FT 8 FT 10 ft A-25 B-45 C-60 C-80 Width C C C C B B B B A A A A (ft) (PSF) (ft) (ft) (ft) (ft) (ft) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) 6 2400 25 25 25 25 12 18 30 36 36 26 27 45 56 4 15 15 28 8 1800 25 25 25 19 12 18 30 36 36 26 27 45 56 4 15 15 28 10 1241 25 25 19 15 12 18 30 36 36 26 27 45 56 4 15 15 28 12 830 25 17 13 9 12 18 30 36 36 26 27 45 56 4 15 15 28 14 595 21 12 9 6 12 18 30 36 n/a 26 27 45 n/a 4 15 15 n/a 16 447 15 8 6 5 12 18 30 36 n/a 26 27 45 n/a 4 15 15 n/a Notes; 1) All information on sheets 12 14 apply to this table.

6 APS CASE 1-2 Standard APS Shield w/ End Sheeting Table 1-2 CAPACITY AND ALLOWABLE DEPTH FOR APS SHIELDS w/ END SHEETING SHIELD HEIGHT 4 FT, 6 FT, 8 FT, 10FT SHIELD HEIGHT Vertical Pipe Clearance Spreader Spacing Top Spreader Location Shield Allowable Depth Allowable Capacity Length Trench 4 FT 6 FT 8 FT 10 FT 4 FT 6 FT 8 FT 10 ft 4 FT 6 FT 8 FT 10 ft A-25 B-45 C-60 C-80 Width C C C C B B B B A A A A (ft) (PSF) (ft) (ft) (ft) (ft) (ft) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) 6 2400 25 25 25 25 8 18 30 36 36 26 27 45 56 4 15 15 28 8 1800 25 25 25 19 8 18 30 36 36 26 27 45 56 4 15 15 28 10 1241 25 25 19 15 8 18 30 36 36 26 27 45 56 4 15 15 28 12 830 25 17 13 9 8 18 30 36 36 26 27 45 56 4 15 15 28 14 595 21 12 9 6 8 18 30 36 n/a 26 27 45 n/a 4 15 15 n/a 16 447 15 8 6 5 8 18 30 36 n/a 26 27 45 n/a 4 15 15 n/a Notes; 1) Adjustable spreaders with TS5x5x3/16 steel over sleeves or power struts with TS8x4x3/16 over sleeves are used in this configuration 2) Allowable sheeting is Pacific Shoring corrugated aluminum sheeting or equivalent Steel sheet piling ½ thick steel plate 2 thick timber 1-1/8 thick Plywood ¾ Finnform 3) The maximum trench width for this configuration is 8 ft. 4) End sheeting shown is for full height of shield, if shield is held 2 off bottom of excavation sheeting shall be embedded a min. 2 into bottom of excavation. 5) End sheeting can only be used with static spreaders if shield is fully confined by either: a. Filling in area between shield sides and excavation walls with soil, along the entire length of shield b. End loading shield on both ends, with less than 6 inches between shield end and excavation wall. 6) All information on sheets 12 14 apply to this table.

7 APS CASE 1-3 Standard APS Shield w/ End Panel Table 1-1 CAPACITY AND ALLOWABLE DEPTH FOR SHIELD HEIGHT 4 FT, 6 FT, 8 FT, 10FT SHIELD HEIGHT Vertical Pipe Clearance Spreader Spacing Top Spreader Location Shield Allowable Depth Capacity Allowable Length Trench 4 FT 6 FT 8 FT 10 FT 4 FT 6 FT 8 FT 10 ft 4 FT 6 FT 8 FT 10 ft A-25 B-45 C-60 C-80 Width C C C C B B B B A A A A (ft) (PSF) (ft) (ft) (ft) (ft) (ft) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) 6 2400 25 25 25 25 12 18 30 36 36 26 27 45 56 4 15 15 28 8 1800 25 25 25 19 12 18 30 36 36 26 27 45 56 4 15 15 28 10 1241 25 25 19 15 12 18 30 36 36 26 27 45 56 4 15 15 28 12 830 25 17 13 9 12 18 30 36 36 26 27 45 56 4 15 15 28 14 595 21 12 9 6 12 18 30 36 n/a 26 27 45 n/a 4 15 15 n/a 16 447 15 8 6 5 12 18 30 36 n/a 26 27 45 n/a 4 15 15 n/a Notes; 1) All information on sheets 12 14 apply to this table.

8 APS CASE 1-4 Standard APS Shield w/ 4 Stacker Shield Table 1-1 CAPACITY AND ALLOWABLE DEPTH FOR SHIELD HEIGHT 4 FT, 6 FT, 8 FT, 10FT SHIELD HEIGHT Vertical Pipe Clearance Spreader Spacing Top Spreader Location Shield Allowable Depth Capacity Allowable Length Trench 4 FT 6 FT 8 FT 10 FT 4 FT 6 FT 8 FT 10 ft 4 FT 6 FT 8 FT 10 ft A-25 B-45 C-60 C-80 Width C C C C B B B B A A A A (ft) (PSF) (ft) (ft) (ft) (ft) (ft) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) (in) 6 2400 25 25 25 25 12 18 30 36 36 26 27 45 56 4 15 15 28 8 1800 25 25 25 19 12 18 30 36 36 26 27 45 56 4 15 15 28 10 1241 25 25 19 15 12 18 30 36 36 26 27 45 56 4 15 15 28 12 830 25 17 13 9 12 18 30 36 36 26 27 45 56 4 15 15 28 14 595 21 12 9 6 12 18 30 36 n/a 26 27 45 n/a 4 15 15 n/a 16 447 15 8 6 5 12 18 30 36 n/a 26 27 45 n/a 4 15 15 n/a Notes; 1) All information on sheets 12 14 apply to this table.

9 APS CASE 2-1 High Clearance APS Shield TABLE 2-1 ALLOWABLE DEPTH FOR 8'& 10' APS BOX WALL PANELS Panel Maximum Depth for Soil Type (ft) Capacity Length OSHA Soil Type (ft) (PSF) A25 B45 C60 C80 6 1055 25 22 16 13 8 791 25 18 14 11 10 633 22 14 12 9 12 527 18 12 10 8 Strut Location C (ft) Notes; 1) All information on sheets 12 14 apply to this table. 2) Cylinders are NOT to be hydraulically linked in case 2-1. Pressurized cylinders must be hydraulically independent of each other.

10 APS CASE 2-2 HC - APS w/ Horizontal Power Struts & End Sheeting TABLE 2-1 ALLOWABLE DEPTH FOR 8'& 10' APS BOX WALL PANELS Panel Maximum Depth for Soil Type (ft) Capacity Length OSHA Soil Type (ft) (PSF) A25 B45 C60 C80 6 1055 25 22 16 13 8 791 25 18 14 11 10 633 22 14 12 9 12 527 18 12 10 8 Strut Location C (ft) Notes; 1) Horizontal Power Struts w/ 8x4x3/16 Steel Tube over sleeves is used in this configuration but limits the shield s psf rating to 900 psf. 2) Allowable sheeting is ; Pacific Shoring corrugated aluminum sheeting or equivalent Steel sheet piling ½ thick steel plate 2 thick timber 3) The maximum trench width for this configuration is 8 ft with two Horizontal Power Struts w/ 8x4x3/16 steel tube over sleeves. For 10ft max. trench width use additional power strut or APS adjustable spreader with over sleeves at lower strut location. 4) Maximum cantilever of sheeting below bottom most strut or spreader is 2, if distance is greater than 2 then additional bracing or a min. 2 of embedment into bottom of excavation is required.

11 APS CASE 3-1 High Clearance APS Shield w/ Corner Posts & Panels Table 1-APS - HIGH CLEARNCE CAPACITY AND ALLOWABLE EXCAVATION DEPTH Shield Strut Locations Hydraulic/Static Mode Allowable Depth Stackable Height Length Capacity C B A A-25 B-45 C-60 C-80 Height (ft) (ft) (ft) (psf) (in) (in) (in) (ft) (ft) (ft) (ft) 12 8 6 1055 2 4.33 25 22 16 13 12 8 8 791 2 4.33 25 18 14 11 12 8 10 633 2 4.33 22 14 12 9 12 8 12 527 2 4.33 14 12 10 8 14 10 6 1055 4 4.33 25 22 16 13 14 10 8 791 4 4.33 25 18 14 11 14 10 10 633 4 4.33 22 14 12 9 14 10 12 527 4 4.33 14 12 10 8 Notes; 1) All information on sheets 12 14 apply to this table.

12 Aluminum Panel Shields Notes Table 1 Notes 1. Shield pipe clearances and wale spacing shown here can be changed on request. When the shields are shipped, tabulated data for the different configurations will be provided. 2. Shields may be stacked. 3. In sloped excavations the maximum depth is 20 ft. 4. Shields may be held 2 ft off the bottom of the excavations in OSHA Type A and B soil only 5. Pipe clearance can be increased in Type A and B soil if the shield is held 2 ft off the bottom 6. In sloped excavations, slope in accordance with OSHA Soil Type as follows; Type A ¾:1 Type B 1:1 Type C 1-1/2:1 7. In sloped excavations the hinge point must be minimum 18 from the top of the shield 8. In hydraulic mode allowable depths may be increased 10% to a maximum of 25 ft. Hydraulic mode is when all struts are pressurized to 750 psi and the shield walls are in contact with the soil. Static Mode is when the struts are pinned or not pressurized against the trench wall.

13 Aluminum Panel Shields () -Table 4-Shield Weights Table 4- SHIELD WEIGHT Shield Shield Shield Shield Capacity Weight Capacity Weight Height Length Height Length (ft) (ft) (PSF) (lbs) (ft) (ft) (PSF) (lbs) Table 4 Notes 4 6 2400 480 8 6 2400 960 4 8 1800 640 8 8 1800 1280 4 10 1241 800 8 10 1241 1600 4 12 830 960 8 12 830 1920 4 16 447 1280 8 16 447 2560 6 6 2400 720 10 10 1241 2000 6 8 1800 960 10 12 830 2400 6 10 1241 1200 6 12 830 1440 6 16 447 1920 1. Use a factor of safety of 5 for rigging cables and connections 2. Shield weights are approximate. If the shield is wedged in, the lifting force will be higher than tabulated weight.

14 Aluminum Panel Shield Installation and Removal Installation 1. Shields shall be assembled and properly rigged for lifting prior to setting inside the excavation. 2. Set shield inside the trench. Workers are not allowed under moving loads at any time. 3. If trench walls are more than 6 from the wall of the shield, back fill the void with crushed rock or excavated soil a minimum of ½ the shield wall area. 4. If the shield is held 2 ft off the bottom of the trench, the bottom of the shield shall rest on a bench or be otherwise supported so that it cannot fall to the bottom of the trench. Removal 1. If shields are stacked attach lifting equipment to the bottom shield prior to removing the top shield 2. If the shield is wedged in by soil, the additional pulling force may exceed the strength of the lifting harness or the connection of the lifting eyes. Use extreme caution when forcing shields out of an excavation. Safe Handling and Use of Aluminum Panel Shields 1. A competent person shall inspect the shield on a daily basis while it is in use in the trench. Check for; Lift hooks are properly connected and holes are not rounded or bent Check for broken welds at all weld locations Check strut pins for safety lock pin in place, and excessive wear Check strut pin holes for elongation or tearing. Check strut to make sure it is not bent or dinged Workers may be inside the shield when it is being moved horizontally but not when it is being lifted. Workers shall stay back minimum 10 ft when a shield is wedged inside an excavation and being lifted with force to get it out of the excavation. If shields need repairs, the shield shall be taken out of service until it is recertified by a Registered Civil Engineer.