ASD LED Edge lit Flat Panels are modern, cutting edge fixtures producing 11 lm/w. This Edge lit panel measures only 1/2 thick making it one of the slimmest panels in the marketplace today. Our UL and DLC Standard rated panel is high efficiency, absent of hazardous materials and maintenance-free. Hybrid emergency system with integrated signal indicator provides 9-minute emergency operation with no additional wiring required, installation is fast and simple. Our LED panels are an ideal choice to reduce energy costs in commercial and residential applications. They are most commonly used in offices, schools, hospitals, retail stores and airports. ASD LED Edge lit flat panels have low energy consumption, long life and a nice even light virtually eliminating glare and shadows. FEATURES AND BENEFITS: 9+ minutes of emergency operation 35% emergency light level output < 24 hours battery charging time Low energy consumption Luminous efficiency 11-up lm/w White frame Available in 2x2 and 2x4 sizes Standard ~1 V dimming L-7 Life > 81, hrs DesignLights Consortium (DLC) listed (Classification: Standard) UL certified 5-year limited warranty ORDERING MATRIX: 11 HIGH LUMINOUS EFFICIENCY Family Modification Size Dimmable ~1 V Watts CCT Series ASD-ELP 12 XX D XX XX SHE Edge-Lit Panel = type 2x2 Dimmable 27 = 27 W 3,5 K Standard 24 = type 2x4 4 = 4 W 4, K Hybrid 5, K LED EDGE-LIT PANEL STANDARD HYBRID EMERGENCY: Model Type Watts Dimming Lumens Dimensions CCT Normal Compatible Normal Emerg. (calc) (LxWxH) ASD-ELP12-D2735-SHE 2х2 27 W 1 W yes 3,5 K 3, lm 1,12 lm 23.7" х 23.7" х.4" ASD-ELP12-D274-SHE 2х2 27 W 1 W yes 4, K 3,85 lm 1,3 lm 23.7" х 23.7" х.4" ASD-ELP12-D275-SHE 2х2 27 W 1 W yes 5, K 3,139 lm 1,163 lm 23.7" х 23.7" х.4" ASD-ELP12-24D435-SHE 2х4 4 W 17 W yes 3,5 K 4,553 lm 1,935 lm 47.75" x 23.7" x.4" ASD-ELP12-24D44-SHE 2х4 4 W 17 W yes 4, K 4,671 lm 1,985 lm 47.75" x 23.7" x.4" ASD-ELP12-24D45-SHE 2х4 4 W 17 W yes 5, K 4,779 lm 2,31 lm 47.75" x 23.7" x.4" WebSite: www.asd-lighting.com Fax: 339-52-897
PRODUCT SPECIFICATIONS: Construction & Materials Housing Aluminum Lens Translucent white Finish White Weight ASD-ELP12-D2735-SHE 8.95 lbs (4.7 kg) ASD-ELP12-24D435-SHE 16.21 lbs (7.37 kg) ASD-ELP12-D274-SHE ASD-ELP12-24D44-SHE ASD-ELP12-D275-SHE ASD-ELP12-24D45-SHE Environmental System Work Environment Indoor use Operating Temperature to (-1 to +4 ) Humidity 2% - 85% RH, non condensing L7 Life > 81, hrs Optical System Luminous Flux ASD-ELP12-D2735-SHE 3, lm ASD-ELP12-24D435-SHE 4,553 lm ASD-ELP12-D274-SHE 3,85 lm ASD-ELP12-24D44-SHE 4,671 lm ASD-ELP12-D275-SHE 3,139 lm ASD-ELP12-24D45-SHE 4,779 lm Color Temperature 3,5 K, 4, K, 5, K CRI 8 Electrical System Input Voltage 1~277VAC 5/6 Hz Max input current ASD-ELP12-D2735-SHE.4 A ASD-ELP12-24D435-SHE.6 A ASD-ELP12-D274-SHE ASD-ELP12-24D44-SHE ASD-ELP12-D275-SHE ASD-ELP12-24D45-SHE Inrush current 5 A Action time (Inrush current).5s AC input range min 1 V max 35 V Off State Power W Power Consumption ASD-ELP12-D2735-SHE 27 W ASD-ELP12-24D435-SHE 4 W ASD-ELP12-D274-SHE ASD-ELP12-24D44-SHE ASD-ELP12-D275-SHE ASD-ELP12-24D45-SHE Power Factor.99 Output voltage ASD-ELP12-D2735-SHE 3-4 V ASD-ELP12-24D435-SHE 3-4 V ASD-ELP12-D274-SHE ASD-ELP12-24D44-SHE ASD-ELP12-D275-SHE ASD-ELP12-24D45-SHE Max output current ASD-ELP12-D2735-SHE 7 ma ASD-ELP12-24D435-SHE 1,1 ma ASD-ELP12-D274-SHE ASD-ELP12-24D44-SHE ASD-ELP12-D275-SHE ASD-ELP12-24D45-SHE LED driver class P, class 2 system Battery charging time < 24 hours operation time 9 minutes watts ASD-ELP12-D2735-SHE ASD-ELP12-24D435-SHE ASD-ELP12-D274-SHE 1 W ASD-ELP12-24D44-SHE 17 W ASD-ELP12-D275-SHE ASD-ELP12-24D45-SHE Luminous Flux ASD-ELP12-D2735-SHE 1,12 lm ASD-ELP12-24D435-SHE 1,935 lm ASD-ELP12-D274-SHE 1,3 lm ASD-ELP12-24D44-SHE 1,985 lm ASD-ELP12-D275-SHE 1,163 lm ASD-ELP12-24D45-SHE 2,31 lm Control Dimming Switch Standard ~1 V dimming 5% - 1% Regular and Voluntary Certifications 5-year limited warranty DesignLights Consortium (DLC) listed (Classification: Standard) UL certified E4754 - Recessed mounted panel WebSite: www.asd-lighting.com Fax: 339-52-897
TYPE 2x2 27W 23 3/4" (63 mm) 2 1/4" (3 mm) 3,5K C PLANE ISOLUX DIAGRAM (UNIT:lx) 1 -/+ -15 15-12 12 23 3/4" (63 mm) -9-6 2 4 6 8 9 6 3 1/4" (1 mm) -3 1 3 C/,1.9 C3/21,1.4 C6/24,1.4 C9/27,1.6 5. 16.5 33. 5.9.98 S(m) 4.9.78 3.9.49 AVERAGE BEAM ANGLE(5%):1.6 DEG 2.9 2..39.29 4,K C PLANE ISOLUX DIAGRAM (UNIT:lx) 5,K 1 C PLANE ISOLUX DIAGRAM (UNIT:lx) 1 -/+ -/+ -15 15-15 15-12 12-12 12 3 3-9 9-9 9 19 2-6 57 76 6-6 4 6 8 6-3 95 3 C/,1.8 C3/21,1.2 C6/24,1.1 C9/27,1.3 AVERAGE BEAM ANGLE(5%):1.4 DEG 5. 16.5 33. 5.6.94 S(m) 4.7.75 3.7.47 2.8.37 1.9.28-3 1 3 C/,1.9 C3/21,1.4 C6/24,1.3 C9/27,1.5 AVERAGE BEAM ANGLE(5%):1.5 DEG 5. 16.5 33. 5.8.97 S(m) 4.9.78 3.9.49 2.9.39 1.9.29 TYPE 2x4 4W 48 3/4" (1213 mm) 2 1/4" (3 mm) 3,5K C PLANE ISOLUX DIAGRAM (UNIT:lx) 1 -/+ -15 15-12 12 23 3/4" (63 mm) -9-6 4 8 12 16 9 6 3 1/4" (1 mm) -3 2 3 C/,113.9 C3/21,113.3 C6/24,113.5 C9/27,113.7 AVERAGE BEAM ANGLE(5%):113.6 DEG 5. 16.5 33. 9.1 1.5 S(m) 7.6 1.2 6.1.76 4.6.61 3.. 4,K C PLANE ISOLUX DIAGRAM (UNIT:lx) 5,K 1 C PLANE ISOLUX DIAGRAM (UNIT:lx) 1 -/+ -/+ -15 15-15 15-12 12-12 12 3 3-9 9-9 9 4 4-6 8 12 16 6-6 8 12 16 6-3 2 3 C/,113.9 C3/21,113.4 C6/24,113.6 C9/27,113.9 5. 16.5 33. 9.3 1.5 S(m) 7.7 1.2 6.2.77-3 2 3 C/,113.9 C3/21,113.2 C6/24,113.3 C9/27,113.5 5. 16.5 33. 9.3 1.5 S(m) 7.7 1.2 6.2.77 AVERAGE BEAM ANGLE(5%):113.7 DEG 4.6 3.1.62. AVERAGE BEAM ANGLE(5%):113.5 DEG 4.6 3.1.62. WebSite: www.asd-lighting.com Fax: 339-52-897
PACKAGE CONTENTS: Description Q-ty LED Edge-Lit Flat Panel 2 Box 1 Installation Instructions 3 ELECTRICAL SCHEMATIC DIAGRAM LED DRIVER LED DRIVER LED DRIVER Dim- Dim + L SWL N Ground Dim- Dim + L SWL N Ground Dim- Dim + L SWL N Ground Dim + (Violet) Dim - (Gray) X PANELS Power connector 12~277V 5/6 Hz L (live/hot) connect black N (neutral) connect white G (ground) connect green X PANELS Connect the battery plug before wiring WARNING RISK OF PERSONAL INJURY READ and follow all WARNINGS and installation instructions. Keep or give to the owner for future reference. Risk of cuts: Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing, and maintaining this product. Risk of electric shock: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Risk of Fire: Minimum 9 С supply conductors. Consult a qualified electrician to ensure correct branch circuit conductor. ASD assumes no responsibility for claims arising out of improper or careless Installation or handling of this product. For recessed installation: Access above ceiling required. Inherently protected. Vapor barrier must be suitable for 9 C. WebSite: www.asd-lighting.com Fax: 339-52-897
Malfunction Charging Main Power TEST LED Edge-Lit Flat Panels EMERGENCY SYSTEM DETAILS BATTERY BACK-UP INFORMATION Battery capacity Max emergency output power current operation time Battery voltage Full charge/ discharge cycles 2,mA * 4 1 W 3 ma 9 minutes.4 V 3 cycles 2,mA * 6 17 W 5 ma 9 minutes 1.8 V 3 cycles SIGNAL INDICATOR Red LED: Charged Green LED: Main Power Yellow LED: Malfunction Standard operation display status Operating Condition Main Power Charged Malfunction Light Light ON ON Slow Flashing/OFF OFF ON work OFF ON OFF ON Light OFF ON / Slow Pulsing Slow Flashing/OFF OFF OFF 1. When red LED flashes and green LED is lit, the battery is on charge. 2. When the battery gets fully charged, red LED goes off and green LED lights up. Malfunction Charging Main Power TEST Warning display status Operating Condition Main Power Charged Malfunction Light No AC and Battery is out OFF OFF OFF OFF No AC and Battery is low OFF Fast Blinking OFF ON Battery is not Connected - - Fast Blinking - Fault Current - - ON OFF WARNING This product should be installed by a qualified electrician. Connecting wires when power is on is not allowed. Power can be turned on after making sure that there is no phenomenon of short circuit and the connection is ok. The wall switch only controls the main power, does not affect emergency lighting. Green light - main power, Red light - charging, Yellow light malfunction. Test - test button Frequent tests are prohibited. Interval between tests should be not less than one minute. WebSite: www.asd-lighting.com Fax: 339-52-897
INSTALLATION GUIDE IMPORTANT SAFETY INFORMATION: Please read all the instructions below before installation. Make sure that the supply voltage corresponds to the rated product voltage. The product is designed for indoor use only. RECESSED MOUNT 1. Choose the ceiling panel where you want to install the product, and remove it. For convenience, move adjacent ceiling tiles. 2. Fix the LED Panel into the ceiling: raise up the product above the bar, then place it on T-bars. 3. Secure the panel with the grid as shown in the picture. Connect wires as shown in electrical schematic diagram above. 4. Return the adjacent ceiling tiles to their places. 5. Turn on the main power. Installation is finished. Compatible with grid size Two bend points for all four tabs Ensure the tab is securely attached to the grid 15/16" Slot T 15/16" Tegular SURFACE MOUNT Wall/ceiling mount: 1. Put the pieces of frame to any horizontal surface. Connect these 3 pieces of the frame to the ceiling using four screws. 2. Connect the panel wires as shown in electrical schematic diagram. Attach the fourth piece and secure with screws. 3. Turn on the main power. Installation is complete. Accessories for surface mount are sold separately. FRAME FOR SURFACE MOUNTING ORDERING INFORMATION: GTIN 12 Model Number Panel Size 85996153 ASD-FELP 2x2 8599615339 ASD-FELP24 2x4 Connect three pieces together with screws (included) Insert the panel into the frame formed by three connected pieces WebSite: www.asd-lighting.com Fax: 339-52-897
RECESSED SHEETROCK MOUNT 1. Following the picture above, slide part B into the inboard side of parts C and A as shown. 2. Place assembled frame into a ceiling opening and add steel wires for support as pictured below. B A A - End/intermediate Rail B - Corner Angle C - Side Rail C B A C Corner angle on inside of end and side rails Steel wire Note: For best results, attach supporting steel wires going into the ceiling to sides of frame after assembly End rail can be used as intermediate rail for tandem row After wiring fixture, carefully slide it through ceiling opening, rotate and drop fixture into place. Accessories for recessed sheetrock mount are sold separately. FRAME FOR RECESSED SHEETROCK MOUNTING ORDERING INFORMATION: GTIN 12 Model Number Panel Size 855296393 ASD-FDW-ELP 2x2 8576617 ASD-FDW-ELP24 2x4 SUSPENDED MOUNT (only for 2x2 and 1x4 LED Edge-Lit flat panels): 1. Make sure that the ceiling can hold the weight of the LED panel and install ceiling brackets suitable to support the weight of the LED panel. Affix cables. 2. Connect the wires as shown in electrical schematic diagram. 3. Attach the suspended cables to the bends at the edges of the LED flat panel. 4. Turn on the main power. Installation is finished. Accessories Set х 12 х 12 х 4 х 4 х 4 Accessories for suspended mount are sold separately. CEILING HANGING SET ORDERING INFORMATION: GTIN 12 Model Number Suspended cables lenghs 85996158 ASD-CHS4 4 ft (1 mm) 8552965 ASD-CHS6 6 ft (3 mm) WebSite: www.asd-lighting.com Fax: 339-52-897
ORDERING INFORMATION LED EDGE-LIT PANEL STANDARD HYBRID EMERGENCY Model Type Watts CCT UPC GTIN Product Code Pcs in one Carton Carton Size Carton Weight ASD-ELP12-D2735-SHE 2х2 27 W 3,5 K 819212193 1921219 21.164 2 24.6"x24.6"x2.76" 19.36 lbs ASD-ELP12-D274-SHE 2х2 27 W 4, K 819212119 19212116 21.165 2 24.6"x24.6"x2.76" 19.36 lbs ASD-ELP12-D275-SHE 2х2 27 W 5, K 8192121116 192121113 21.166 2 24.6"x24.6"x2.76" 19.36 lbs ASD-ELP12-24D435-SHE 2х4 4 W 3,5 K 8192121123 19212112 21.167 2 48.6"x24.6"x2.76" 36.3 lbs ASD-ELP12-24D44-SHE 2х4 4 W 4, K 819212113 192121137 21.168 2 48.6"x24.6"x2.76" 36.3 lbs ASD-ELP12-24D45-SHE 2х4 4 W 5, K 81921217 1921214 21.169 2 48.6"x24.6"x2.76" 36.3 lbs WebSite: www.asd-lighting.com Fax: 339-52-897