3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide

Similar documents
Cable Ties. Data Sheet

3M Ladder Kit 3M710/MS 2 -TMK-LK

3M Locator Plate

3M Locator Plate

Data Sheet July For RoHS information, please visit

3M Mechanical Shearbolt Connectors, QCI Series

3M Closure System 2-Type Cover (505)

3M Cable Ties Product Guide. Made in USA. & Plenum Rated

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

710 Splicing Rig. Instructions. January E

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Pleated Foil I/O Cable Assemblies MDR Series

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

3M Cold Shrink QT-III Silicone Rubber Termination

3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm

3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array

SLiC Aerial Closures

GM Specification Annual Test Data

3M Fiber Dome Closure FDC 10

Branch Splice QS-2001B

GM Specification Annual Test Data

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3M Cold Shrink Splice Kit QS-III 5536A

3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Video Data Transmission System, 50 Position 14X50-SZWB-XXX-0NC

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Volition. VF-45 Quick Install kit. and Maintenance Cleaning Kit. 3Innovation

3M Three-Wall and Four-Wall Headers. Series 3XXX

3M Products for Electrical Networks Wind Farm Capabilities. Leading Edge. Electrical Solutions for. Wind Farms

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

3 740 Wrist strap + shoe tester

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

3M TM Cubitron TM II Bonded Abrasive Grinding and Cut-Off Wheels. born to. grind. It s grinding reinvented. Featuring. cut & grind wheels

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

3M CP2 Press-Fit Headers and Sockets, 2 mm

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED.

3 Reenterable Encapsulated PST Dome Closure

Volition. Fiber Optic Cable. 3Innovation

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

Door Edge Protection Film 36 inch

3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

DOCUMENT OBSOLETE. Volition. VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. CLEAN UP YOUR ACT. VF-45 Socket Termination Kit

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

DOCUMENT OBSOLETE. 3M710 UniPresser for 25-Pair Modular Splicing. Instructions. April B

Installing the Boom Mount ET 350 Monitor (Model ET 350R)

Repair Method for 3M Resilient Floor Protection System

3M Collision Repair Solutions. 3M Abrasives and Power Tools. Cutting & Grinding. for Body Techs

Technical Data 3M Petroleum Sorbents

3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief

K SERIES PUSH ON & BULLET TERMINALS

8400 Series Fiber Distribution System

3M Automotive Aftermarket. 3M Blue Abrasives. The upgrade you ve been waiting for.

Model 1100B CHG Terminator. Installation Instructions

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive

3M Abrasive Systems Random Orbital Abrasive Disc Portfolio. Sanding & Finishing. Solutions. see inside. Distributed by:

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Dual Lock Reclosable Fasteners Roll Goods with Pressure Sensitive Adhesive

QT-III Cold Shrink Silicone Rubber

Automotive-Ready Portfolio of 3M Double Sided Tapes. Ready to go further. The future of automotive design begins here.

Scale Feeder Manifold Water Filtration System Instruction Manual

SMC/Fiberglass Repair Adhesive - 90

protect mask conduct reflect enhance 3M Specialty Tape Solutions

3M Ionized Air Gun 980/980E. User s Guide

Shaping. the future. Introducing. 3M Cubitron II Abrasive Belts NEW! 994F and 997F for high pressure applications

Installation Instructions for Part #: KRB01 Radiator and Reserve Tank Relocation Kit for K-Powered Civics

Finish Line. Redefining The. NEW 3M Elite Series Air-Powered Random Orbital/Orbital Sanders NEW 3M Electric Random Orbital Sanders

3M Housings CH Series

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Dual Flow Manifold Systems Instruction Manual

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Conductor Strength Tests on ACCR 1622TW T13 Pecos Conductor

ipd Catback Oval Tube Exhaust System S60R ( ), V70R ( ) ipd #120056

Installation Instructions

Series Description. 2 Specifications. Traffic Safety and Security Division. Product Bulletin Series 4000ESV 06/2017

INSTALLATION, MAINTENANCE & SERVICE MANUAL

3 980/980E Ionized Air Gun Instruction Manual

Transcription:

3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide Installing Tall Skirt on SVC and SVE cabinets Instructions July 2016 78-0015-3067-0

2 July 2016 78-0015-3067-0 Contents 1. General 2. Kit contents 3. Tall skirt installation on back of 3M Cross Connect Cabinet SVC 4. Tall skirt installation on side of 3M Cross Connect Cabinet SVC 5. Tall skirt installation on back of 3M Cross Connect Cabinet SVE DSLAM 1 Right Side 6. Tall skirt installation on back of 3M Cross Connect Cabinet SVE DSLAM 2 Left Side 7. Tall skirt installation on side of 3M Cross Connect Cabinet SVE DSLAM 3 Left Side 8. Tall skirt installation on side of 3M Cross Connect Cabinet SVE DSLAM 4 Right Side 9. Bonding, mounting accessories and terminating cables 1.0 General 1.1 These instructions provide the information necessary for the installation of the tall skirt on the back and side of a 3M Cross Connect Cabinet 4220SV series. Use for stake, hand hole or pad mounted cabinets. One tall skirt needed for each DSLAM. Provides cable protection from ground/pad to bottom of DSLAM. Recommended DSLAM mounting order 1.2 Tools required for installation: UAE socket set Drill and drill bit Standard hand tools 13/64 Drill bit - for holes to attach skirt 1.3 Additional materials or accessories that may be needed for installation. Pallet mounting clips and hardware from cabinet Stakes Mounting ring Rear cable access cover (SVB/SVC) Rear cable access cover (SVE) Stabilizer (SVC) 2.0 Kit Contents 2.1 3M Cross-Connect Cabinet 4220SVC 1 tall skirt assembly 10 Self threading screws *Install tall skirt before mounting DSLAM.

78-0015-3067-0 July 2016 3 3.0 Tall skirt installation on a 3M Cross-Connect Cabinet 4220SVC 3.1 Remove the front panel from the skirt assembly. 3.3 Move the tall skirt away from the cabinet and drill the holes in the cabinet. Front panel 3.2 Place the tall skirt against the back of the cabinet and align the left side surface of the tall skirt flush with the left side surface of the cabinet. Transfer the tall skirt mounting holes to the cabinet back. 3.4 If you are using rear cable access cover, place it on the assembly prior to installing the tall skirt. 3.5 Place the tall skirt into position and fasten to back of the cabinet using the self-threading screws provided with the kit. 3.6 Remove knock outs if required and route DSLAM and fiber cables through the opening. Route the power and ground wire through the small knock outs if required. 3.7 Seal the openings per you company practice.

4 July 2016 78-0015-3067-0 Power cable access hole (optional) Ground cable access hole (optional) 3.8 Attach the front panel to the tall skirt after the DSLAM is mounted. 4.3 Move the tall skirt away from the cabinet and drill the holes in the cabinet. 4.0 Tall skirt installation on side of 3M Cross-Connect Cabinet SVC 4.1 Remove the front panel from the skirt assembly. 4.2 Place the tall skirt against the left side of the cabinet. align the left side of the tall skirt with the front surface of the cabinet. Transfer the tall skirt mounting holes to the cabinet side and the side of the rear mounted tall skirt.

78-0015-3067-0 July 2016 5 4.4 Place the tall skirt into position and fasten to the side of the cabinet using the self-threading screws provided with the kit. 4.8 Attach the front panel to the tall skirt after the DSLAM is mounted. 4.5 Remove the knock out in the side of the rear tall skirt. *(Optional cable routing is through the large knock out in the side of the cabinet) Remove large knock out (if routing cable to the rear of the cabinet) 4.6 Route DSLAM and fiber cables through the opening. Route the power and ground wire through the small knock outs on the side of the cabinet if required. 4.7 Seal the openings per your company practice. 5.0 Tall skirt installation on back of 3M Cross-Connect Cabinet SVE with DSLAM 1 right side 5.1 1st DSLAM Location: Remove the front panel from the skirt assembly. 5.2 Attach rear cable access cover (SVE) Rear cable access cover

6 July 2016 78-0015-3067-0 5.3 Place the tall skirt against the right rear of the cabinet. Align the right side of the tall skirt so it is flush with the right side of the cabinet. Transfer the tall skirt mounting holes to the cabinet back. 5.5 Place the tall skirt into position and fasten to the back of the cabinet using the self-threading screws provided with the kit. 5.4 Move the tall skirt away from the cabinet and drill the holes in the cabinet. 5.6 Remove knock outs if required and route DSLAM and fiber cables through the opening. Route the power and ground wire through the small knock outs if required. 5.7 Seal the openings per your company practice.

78-0015-3067-0 July 2016 7 5.8 Attach the front panel to the tall skirt after the DSLAM is mounted. 6.3 Move the tall skirt away from the cabinet and drill the holes in the cabinet. 6.0 Tall skirt installation on back of 3M Cross-Connect Cabinet SVE with DSLAM 2 left side *Right side tall skirt must be installed prior to installing the left side tall skirt. 6.4 Place the tall skirt into position and fasten to the back of the cabinet using the self-threading screws provided with the kit. 6.5 Route DSLAM and fiber cables through the opening. Route the power and ground wire through the small knock outs on the side of the cabinet if required. 6.1 Remove the front panel from the skirt assembly. 6.2 Place the tall skirt against the left rear side of the cabinet. Align the left side of the tall skirt flush with the left side of the cabinet. Transfer the tall skirt mounting holes to the cabinet back.

8 July 2016 78-0015-3067-0 6.6 Seal the openings per your company practice. 6.7 Attach the front panel to the tall skirt after the DSLAM is mounted. 7.2 Place the tall skirt against the left side of the cabinet. Align the left side of the tall skirt to the left side of the vents on the sidewall and to the right side of the large knock out on the side of the rear tall skirt. Transfer the tall skirt mounting holes to the cabinet sidewall and the left side of the rear mounted tall skirt. 7.0 Tall skirt installation on side of 3M Cross-Connect Cabinet SVE with DSLAM 3 left side *Left side rear tall skirt must be installed prior to installing the left side tall skirt. 7.3 Move the tall skirt away from the cabinet and drill the holes in the cabinet. 7.1 Remove the front panel from the skirt assembly. Vents 7.4 Place the tall skirt into position and fasten to the side of the cabinet and the side of the rear tall skirt using the self-threading screws provided with the kit. 7.5 Remove the large knock out in the side of the rear tall skirt and route the DSLAM and fiber cables through the opening. Route the power and ground wire through the small knock outs on the side of the cabinet if required. *(Optional cable routing is through the large knock out in the side of the cabinet.)

78-0015-3067-0 July 2016 9 7.6 Place the tall skirt into position and fasten to the side of the cabinet using the self-threading screws provided with the kit. 7.7 Route DSLAM and fiber cables through the opening. Route the power and ground wire through the small knock outs on the side of the cabinet if required. Power cable access hole (optional) Ground cable access hole (optional) 7.8 Seal the openings per your company practice. 7.9 Attach the front panel to the tall skirt after the DSLAM is mounted. 8.0 Tall skirt installation on side of 3M Cross-Connect Cabinet SVE with DSLAM 4 right side 8.1 Mounting the fourth DSLAM on the right side of the cabinet is similar to mounting the DSLAM on the left side of the cabinet. *The rear right side DSLAM and tall skirt must be installed before the right side DSLAM and tall skirt. 9.0 Bonding, mounting accessories and terminating cables 9.1 See Instruction 78-0015-2616-5 for information regarding bonding, mounting accessories and terminating cables per 3M MS 2 Splicing Modules, 3M 710 Modules, pedestal, pole mount, hand hole and pad mount cabinet practices.

3M and MS 2 are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any direct, indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. Communication Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 Phone 1-800-426-8688 Web www.3m.com/telecom Please recycle. Printed in USA 3M 2016. All rights reserved. 78-0015-3067-0