Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Similar documents
(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Model Number Structure

Solid State Relays G3NA. Model Number Structure. Model Number Legend

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Model Number Structure

Model Number Structure

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

G3PE-Single-phase. Solid State Relays for Heaters

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Model Number Structure

Model Number Structure

High-power Solid State Relays G3PH

Switching Power Supply

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Inductive Proximity Sensor

G3PE-Single-phase. Solid State Relays for Heaters

G3NA. Model Number Structure. Solid State Relays. Model Number Legend

Solid State Relays for Heaters

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Switching Power Supply

High-power Solid State Relays G3PH

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure

Power Controller. (see note 1) 10 sec

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Model Number Structure

Technical Information Solid State Relays. Glossary. Solid State Relays

Inductive Proximity Sensor

Model Number Structure

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Communications. Auxiliary. Functions. output. functions. Transistor. Heating or cooling control is selectable (See note 2.

Tactile Switch (Hinged Type)

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

24-hour/Weekly Time Switch H2F

Transistor Remote Modules

Digital display Pressure range ON/OFF output Linear output Model

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

H3DS-X - Solid State Two-Wire Timer

Solid State Relays for Heaters

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Surface mounting, flush mounting, and DIN track mounting

Model Pressure range ON/OFF output Linear output

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

Technical Information Solid State Relays. Glossary. Solid State Relays

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Hinged Safety Door Switch

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Model Number Structure

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

E2K-L. Liquid Level Sensor. Applications. Ordering Information

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Switch Mode Power Supply S8VS

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Cylindrical Proximity Sensor

Subminiature Basic Switch

SYSMAC Transistor Remote Module

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Temperature Controllers

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

Model Pressure range ON/OFF output Linear output

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Ordering Information. DC Backup Block for S8TS S8T-DCBU-01. DC Backup Block (See note 1.) Bus Line Connector. Basic Block. Battery Holder.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Digital display Pressure range ON/OFF output Linear output Model

Ordering Information. Text Surface-Mounting Signal Relay G6K

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Analog Output Terminal

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Analog Input Terminal

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Mechanical Key Switch

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Solid State Relays contactor with Integrated Fuse Type RGC1F

E2EZ-X2D1-N E2EZ-X2D2-N

Ordering Information. Text PCB Power Relay G5LE

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Transcription:

SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems, and contributes to maintenance improvements by the user. Main detection items: SSR short-circuits and SSR open-circuits Alarm output possible to NPN/PNP-input devices. The failure-detection function is built-in and power is supplied from the main circuit power supply making wiring simple. Slim design (width: 22.5 mm) incorporating radiator. In addition to screw mounting, DIN track mounting is also possible. Conforms to international standards (IEC, UL, and CSA). Ordering Information X VDE RC Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Accessories (Order Separately) Name Dimensions Model number Mounting Track 50 cm (l) 7.3 mm (t) PFP-50N 1 m (l) 7.3 mm (t) PFP-0N 1 m (l) 16 mm (t) PFP-0N2 Specifications Ratings (At an Ambient Temperature of 25 C) Detection Power Supply 20 A, 0 to 240 VAC (resistive load: AC, Class1) Main Circuit -220B-VD Rated power supply voltage Operating voltage range Current consumption Operating Circuit Input method Rated input voltage Operating input voltage range Must-operate voltage Reset voltage Input current 0 to 240 VAC (50/60 Hz) 75 to 264 VAC (50/60 Hz) 15 ma max. (at 200 VAC) Voltage input 12 to 24 VDC 9.6 to 30 VDC 9.6 VDC max. 1 VDC min. 7 ma DC max. (at rated input voltage) Rated load voltage 0 to 240 VAC (50/60 Hz) Operating voltage range 75 to 264 VDC (50/60 Hz) Rated carry current 20 A (Ta = 40) Minimum load current 0.1 A Inrush current resistance 220 A (60 Hz, 1 cycle) (peak value) Permissible (I 2 t) 260 A 2 S Applicable load (with 4 kw (at 200 VAC) Class-1 AC resistive load) Alarm Output Output OFF collector voltage 30 VDC max. Maximum carry current 0.1 A Output form Independent NPN open collector 3

Characteristics Operate time Release time Main circuit Alarm output Output ON voltage drop OFF leakage current Output ON voltage drop OFF leakage current Engineering Data 1/2 of load power source cycle + 1 ms max. 1/2 of load power source cycle + 1 ms max. 1.6 V rms max. ma max. (at 200 VAC) 1.5 V max. 0.1 ma max. Insulation resistance 0 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance to 55 to Hz, 0.35-mm single amplitude Shock resistance 294 m/s 2 Ambient temperature Operating: -20 to 60 C (with no icing or condensation) Storage: -30 to 70 C (with no icing or condensation) Ambient operating humidity 45% to 85% Weight Approx. 300 g Approved standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) approved by VDE EMC Emission EN55011 Group 1 Class B Immunity ESD IEC947-4-3, EN600-4-2 4 kv contact discharge 8 kv air discharge Immunity Electromagnetic IEC947-4-3, EN600-4-3 V/m (80 MHz to 1 GHz) Immunity EFT IEC947-4-3, EN600-4-4 2 kv AC power-signal line Immunity Surge transient IEC947-4-3, EN600-4-5 2 kv Immunity RF disturbance IEC947-4-3, EN600-4-6 V (0.15 to 80 MHz) Immunity Dips IEC947-4-3, EN600-4-11 Input Voltage vs. Input Current Input Voltage vs. Input Impedance Input impedance (kω) Input current (ma) 8 6 Input impedance Ta = +25 C Load Current vs. Ambient Temperature Load current (A) 25 20 15 Inrush Current Resistivity (Non-repetitive Input) The figure will be less than 1/2 for repetitive input. Inrush current (A. Peak) 250 200 150 4 2 Input current 5 0 50 0 20 30 40 Input voltage (V) 0-20 0 20 40 60 80 0 Ambient temperature ( C) 0 30 50 0 300 500 1,000 3,000 5,000 Energized time (ms) 4

Operation Failure Detection Function Conditions for SSR Failure Detection : Failure mode (See note 1.) Operating input (between terminals A1 and A2) 1. The contents of each of the above failure modes is as follows: SSR short-circuit: SSR output circuit remains in the ON state. SSR half-wave short-circuit: SSR output circuit remains in the ON state in one direction. SSR open-circuit: SSR output circuit remains in the OFF state. SSR half-wave open-circuit: SSR output circuit remains in the OFF state in one direction. In addition to the failure modes listed above, detection of circuit disconnections for the load circuit is also possible. (As a rough guide, circuit disconnection will be detected if the load impedance is greater than or equal to 1 MΩ.) 2. The same power supply is used for both the detection and for the output circuit and so detection is not performed during power interruptions. 3. If power supply (terminal 3) is in the open state, the SSR will still turn ON and OFF in the same way but the failure detection function and alarm display will not operate properly. Connection Diagrams (Main Circuit) Detection time Alarm display (See note 3.) The following diagrams show the applicable load connection configurations for SSR failure detection. Alarm display (between terminals X1 and X2) (See note 3.) SSR short-circuit OFF 0.5 s max. (See note 2.) Red Open collector transistor SSR half-wave short-circuit OFF output SSR open-circuit ON SSR half-wave open-circuit ON Single Phase 3-phase Star Connection 3-phase Delta Connection (3-phase, 2-wire Switching) 3-phase V Connection With 3-phase connection, so that the power supply voltage is applied between the s terminals 1/L1 and 3, connect the desired phase to terminal 3. Timing Chart SSR failure detection Circuit disconnection detection on the load side Main circuit power supply (load side) SSR ON normally SSR OFF normally SSR short-circuit Reset (See note.) SSR open-circuit Reset (See note.) Load circuit disconnection Reset (See note.) Operating input (between terminals A1 and A2) Input LED (yellow) Load current RDY/ALM LED (Green: ; Red: ) Alarm output (between terminals X1 and X2) After failure detection, if the detection conditions differ to the conditions given under Conditions for SSR Failure Detection, alarm output is reset. 5

Dimensions -220B-VD Mounting Holes 130 max. 114.4 22.5 max. Tow, 4.6 dia. Terminal cover 13 Three, 4.5 dia. or M4 68 13.5 8.5x3 = 25.5 0 max. 90±0.2 80 90±0.3 4.5 84.2 The above diagram is for when the terminal cover is open. 4.6x5.6 ntlp 13±0.3 The above diagram is for when the terminal cover is closed. Accessories (Order Separately) Mounting Tracks PFP-0N, PFP-50N PFP-0N2 4.5 7.3±0.15 35±0.3 27±0.15 4.5 Twenty-eight, 25x4.5 elliptic holes 35±0.3 27 24 16 29.2 15 25 25 25 1,000 (500) 25 (see note) 15 (5) (see note) 15 25 25 25 25 15 1 1.5 Values in parentheses indicate dimensions for the PFP-50N. Installation External Specifications Terminal Arrangement Appearance Terminal name Terminal number Screw size Main circuit terminals 1/L1, 2/T1 M4 (output) Detection power supply terminal (input) 3 Operating circuit terminals (input) Alarm output terminals (output) Indicators A1, A2 M3.5 X1, X2 Name Symbol Color Meaning Status indicators RDY Green SSR normal ALM Red SSR failure detection and circuit disconnection detection Input indicator INPUT Yellow Operating 1/L1 3 A1(IN+) A2(IN-) X1(ALM+) X2(ALM-) 2/T1 RDY/ALM INPUT The same indicator is used as both the power supply indicator and the alarm indicator. 6

Connection Example (See note 1.) Display Labels Voltage output for Temperature Controller, sequencer 12 to 24 VDC 1 3 A1 IN A2 L1 AC Input for Temperature Controller, sequencer X1 ALM X2 30 VDC min. 2 T1 : 1. If the detection power supply terminal (terminal 3) is not connected, failure detection is not performed and so be sure to connect this terminal. 2. If the load is connected to terminal 1/L1, failure detection may not operate correctly and so connect the load to terminal 2/T1. 3. With inductive loads (relay coil, etc.), connect back-current prevention diodes to both sides of the load. Precautions!WARNING Do not touch the terminals (i.e., charged parts) of the while power is supplied. Doing so may result in electric shock. If the is provided with a terminal cover, be sure to attach the terminal cover to the before operating the.!warning The and radiator are very hot while power is supplied to the. Do not touch the or the radiator while power is supplied to the or immediately after the is turned OFF. Doing so may result in burns.!warning Do not touch the main circuit terminal of the immediately after the is tuned OFF, otherwise an electric shock may be received due to the residual charge of the built-in snubber circuit.!warning Be sure to turn OFF the power supply to the before wiring, otherwise an electric shock may be received. Mount the terminal cover to the after wiring. Do not touch the terminals of the while power is supplied. Doing so may result in electric shock.!warning (See note 2.) Ensure that a short-circuit current does not flow on the load side of the SSR, otherwise the may be damaged. General Precautions At OMRON, we are constantly working to improve the quality and reliability of our products. SSRs, however, use semiconductors, which are prone to malfunction. Be sure to use SSRs within their rated value. Use the SSR only in systems that are designed with redundancies, flame protection, counter measures to prevent operation errors, and other countermeasures to prevent accidents involving human life or fires. 1. Do not apply voltages or currents to the s terminals in excess of the rated values. Doing so may result in malfunction or burning. 2. Do not use the with terminal screws not properly tightened. Abnormal heating of the terminals may result in burning. 3. Do not obstruct the flow of air around the and the radiator. Abnormal heating of the may result in shortcircuiting of output elements and burning. 4. Perform wiring and tighten screws according to the instructions given under Correct Use. Using the with incorrect wiring or with the screws not tightened properly may result in burning due to abnormal heating of the during use. Correct Use Before Actual Operation 1. In actual operation, the may cause accidents that were unforeseeable at the theoretical stage. Therefore it is necessary to test the under a variety of conditions that are possible. As for the characteristics of the, it is necessary to consider the differences between Units. 2. The ratings in this datasheet are for testing in a temperature range of 15 to 30 C, a relative humidity range of 25% to 85%, and an atmospheric pressure range of 88 to 6 kpa. When testing operation, it is necessary to confirm correct operation not only with the actual load that will be used, but also at the same ambient conditions as for actual operation. Mounting Method DIN Track Mounting When mounting to a DIN track, mount the until it clicks into place, otherwise it become loose during use and fall. Fix both ends with end plates. Panel Mounting When mounting directly to a panel, observe the following conditions: Screw diameter: M4 Tightening torque: 0.98 to 1.47 N m 7

Vertical Mounting Use the at a load current of 50% of the rated load current when it is mounted horizontally. Side-by-side Mounting Panel Wiring Wiring duct 5 mm Wiring duct Vertical direction Use the at a load current of 80% of the rated load current when it is mounted side-by-side. When using crimp terminals, observe the terminal clearances shown below. Main Circuit Power Supply (Terminals 1 to 3) 12.4 Be sure that all lead wires are of a thickness appropriate for the current. The output terminals are charged, and touching them may result in electric shock, even when the is OFF. Separate the outputs from the power supply by installing a circuit-breaker at a higher level in the circuit. Tightening Torque Be sure to tighten the screws to the specified torques given below. Not doing so may result in malfunction. Terminal number Screw terminal Tightening torque diameter A1, A2, X1, X2 M3.5 0.59 to 1.18 N m 2/L1, 2/T1, 3 M4 0.98 to 1.47 N m Operating Conditions 80 mm min. 80mm min. Horizontal Mounting Panel Operating Input/Alarm Output (Terminals A1, A2, X1, and X2) Do not apply current exceeding the rated current. Otherwise, the temperature of the may rise excessively. Be sure to prevent the ambient temperature rising due to the heat radiation of the. If the is mounted inside a panel, install a fan so that the interior of the panel is fully ventilated. Do not use the if heat dissipation fins have been bent as a result of, for example, dropping the. If used in this state, the may be damaged due to the decreased heat dissipation capacity. Only use the with loads that are within the rated values. Using the with loads outside the rated values may result in malfunction, damage, or burning. 7.0 M3.5 Use a power supply within the rated frequency range. Using a power supply outside the rated frequency range may result in malfunction, damage, or burning. Keep wiring separate from high-voltage power lines and use wires of an appropriate length, otherwise malfunction and damage may result due to induction. As protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses and NF breakers on the power supply side. Operating and Storage Environments 1. Operating Ambient Temperature The rated value for the ambient operating temperature of the is for when there is no built-up heat. For this reason, under conditions where heat dissipation is not good due to poor ventilation, and where heat may build up easily, the actual temperature of the may exceed the rated value resulting in malfunction on burning. When using the, design the system to allow heat dissipation sufficient to stay below the Load Current vs. Ambient Temperature characteristic curve. also that the ambient temperature of the may increase as a result of environmental conditions (e.g., climate, air-conditioning) and operating conditions (e.g., mounting in an airtight panel). 2. Operating and Storage Locations Do not use or store the in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. Do not use or store in locations subject to direct sunlight. Do not use in locations subject to ambient temperatures outside the range -20 to 60 C. Do not use in locations subject to relative humidity outside the range 45% to 85% or locations subject to condensation as the result of severe changes in temperature. Do not store in locations subject to ambient temperatures outside the range -30 to 70 C. Do not use or store in locations subject to corrosive or flammable gases. Do not use or store in locations subject to dust (especially iron dust) or salts. Do not use or store in locations subject to shock or vibration. Do not use or store in locations subject to exposure to water, oil, or chemicals. 3. Transportation When transporting the, observe the following points. Not doing so may result in damage, malfunction, or deterioration of performance characteristics. Do not drop the or subject it to severe vibrations or shock. Do not transport the product if it is wet. 4. Vibration and Shock Do not subject the SSR to excessive vibration or shock. Otherwise the SSR may malfunction and internal components may be damaged. To prevent the SSR from abnormal vibration, do not install the in locations or by means that will subject it to the vibrations from other devices, such as motors. 5. Solvents Do not allow the to come in contact with solvents such as thinners or gasoline. Doing so will dissolve the markings on the SSR. 6. Oil Do not allow the terminal cover to come in contact with oil. Doing so will cause the cover to crack and become cloudy. 8

Operation 1. Leakage Current A leakage current flows through a snubber circuit in the even when there is no input. Therefore, always turn OFF the power to the input or load and check that it is safe before replacing or wiring the. Switch element Snubber circuit Input circuit Trigger Varistor Leakage current 2. Screw Tightening Torque Tighten the terminal screws properly. If the screws are not tight, the will be damaged by heat generated when the power is ON. 3. Mounting Do not perform mounting with oil or metal powder on your hands. Doing so may result in damage to the. 4. Dropping Be careful not to drop the during mounting. The weighs approximately 300 g and could cause injury if dropped on any part of your body. 9

11

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J127-E1-1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Industrial Control Components Department Shiokoji Horikawa, Shimogyo-ku Kyoto, 600-8530 Japan Tel: (81)75-344-7119/Fax: (81)75-344-7149 Printed in Japan 0301-2M (0301) (O) 12