OPERATING INSTRUCTIONS

Similar documents
Operating Instructions

Operating Instructions

Product manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

INSTRUCTION MANUAL (ATEX / IECEx)

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Explosion protected terminal boxes type, GHG 72.

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Operating Instructions

INSTRUCTION MANUAL (ATEX / IECEx)

ILED Aquarius Illuminated Windsock. User Manual

ILED Dorado. User Manual

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

IECEx Certificate of Conformity

Ex m Solenoid Operator Type 0519

Operating Instructions

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Junction box for EKL light

Linear Luminaire with LED

Operating Instructions

Technical Data. Dimensions

Linear Luminaire for Fluorescent Lamps

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Clarius EP PLUS LED FLOODLIGHT Installation Guide

EStrong-series Emergency Stop

VALIADIS S.A. HELLENIC MOTORS

Pendant Light Fitting IEC

HTSB system System overview

SynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

CCAI, CCAIF, CCAIF..H

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

M-0. M-0... series control, monitoring and signalling devices. Ex e

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Zone 1 Linear Range - Installation Guide

Terminal Boxes in Stainless Steel SLS**.T

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Floodlight Range Installation Guide

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Number: TEPEx.RS.067 Rev : 02 Date: Manufacturer General safety information s Purpose Degree of protection 2.

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Emergency Luminaire with LED Series EXLUX 6409/1

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

Cubo X Stainless Steel Enclosures

Operating Instructions

Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Floodlight LED Series 6525

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Emergency Light Fitting for Fluorescent Lamps Series 6009

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

SERIES 54 Inductive Proximity Sensor

Floodlight LED Series 6525

Operating instructions Solenoid interlock EX-AZM About this document. Content

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

INSTALLATION &SAFETY DATA SHEET

Compact Sheet-steel Emergency Light Fitting Series 6118/1

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

IECEx Certificate of Conformity

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Control and Terminal Box Type A21-**-*****

Position Switches Series 8060/2

Floodlight LED Series 6125

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Ex e, ia Junction boxes TNCN. Features

Terminal Boxes Series 8125

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Position Switches Series 8070/2

Safety Instructions Proline Promass 300

Solenoid coils VACF Type codes

Load and Motor Switches, Load-Break Switches Series 8549

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

LED Linear Luminaire Series EXLUX 6402

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

Linear luminaire with LED Series EXLUX 6002

EX-REPAIR AND MAINTENANCE RECEPTACLES

Control Buttons / Switches for Panel Mounting Series 8003

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Segurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Glass Reinforced Polyester Enclosures

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6402/2


Linear Luminaire with LED Series EXLUX 6002

MINI MCR-SL-UI-UI(-SP)(-NC)

Floodlight Series 6121

Transcription:

OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical data 7) Fitting 8) Installation 9) Commissioning 10) Repairs and maintenance 11) Accessories and spare parts 12) Disposal 13) Decoration of conformity RTKB 2 RTKB 1 2) GENERAL INFORMATION 2.1) MANUFACTURER: Rteck industries Ltd Telephone: +6473493498 Fax: +6473089055 Bay Of Plenty, New Zealand Internet: www.rteckpacific.com 2.2) INFORMATION ABOUT THE OPERATING INSTRUCTIONS: Rteck Documentation detail is available for download on website Rteck technical files Ex product. We reserve the right to make technical changes without notice. 2.3) PURPOSE OF THESE INSTRUCTIONS: Working in hazardous areas the safety of personal and plant depends on complying with the relevant safety regulations. Assembly and maintenance staff working on installations have a particular responsibility for acquiring precise knowledge of the applicable standards and regulations. This introduction gives a brief summary of the most important safety measures to supplement the corresponding regulations which staff responsible must study for personal duty of care on installation.

3.0) SAFETY INSTRUCTIONS: Use the product / device only for its intended purpose. Incorrect or impermissible use or non compliance with these instructions invalidates our warranty provision. Alterations to the device impairing its explosion protection are not permitted. Users must fit and operate the terminal box only if it is clean and undamaged. OBSERVE the following during installation and operation: National safety regulations National accident prevention regulations National installation regulations Generally recognized technical regulations Safety guidelines in these operating instructions Characteristic values and rated operating conditions on the rating and data plates Additional instructions plates fixed clearly to the device Any change can invalidate the Ex protection WARNING: POTENTIAL ELECTROSTATIC CHARGING HAZARD. SPECIAL NOTE: To minimize the risk of electrostatic discharge, (Only wipe with a damp cloth and ensure no hazardous atmosphere is present before touching), enclosures should not be fitted where they can be subjected to high flow of powder /dust flow that may lead to a prolific charge buildup being generated (e.g.) pneumatic transfer of powders of discharge spraying. 4.0) CONFORMITY TO STANDARDS: Each device complies with the following standards and regulations Directive 94/9/EC EMC Directive No : 89/336/EEC EN/ IEC60079-0, EN/ IEC 60079-7, IEC 60079-31 Device type RTKB series terminal box is suitable for use in hazardous areas, Zones 1,2 and Zones 21, 22 5.0) FUNCTION: The PDE Resin terminal boxes are used for the transfer of electrical energy. 6.0) TECHNICAL DATA: Types RTKB-1 Terminal box without equipment fuse RTKB-2 Terminal box without equipment fuse EXPLOSION PROTECTION Gas explosion protection IEC Ex Ex e IIC T6 Gb IP66 Dust explosion protection Ex tb IIIC T80c IP66 Rated Voltage Max 500V : AC/DC with special cable glands Types RTKBF-1 Terminal box with equipment fuse RTKBF-2 Terminal box with equipment fuse

EXPLOSION PROTECTION Gas explosion protection Dust explosion protection Rated Voltage Ex em T6 Gb Fuse < 4.0A Ex tb IIIC T80c IP66 Max 500V : AC/DC with special cable glands CERTIFICATES Housing Gaskets Cover fixing IEC Ex PDE Thermoplastic Resin Black / impact strength 7nm, material self extinguishing and flame resistant VO-UL 94 IEC 60695-11-10. 4mm Silicone sponge 4 x 4mm Pan pozi slot Head Stainless steel Degree of protection Ambient temperature IP66-20ºc to +40ºc FITTING IN TERMINAL BOXES Maximum number of cables needed to conductor cross section and number of terminals under load for temperature class T6 when Ta < 40c Types: RTKB-1 /2 and RTKBF-1/2

General product information: The Rteck junction box consists of Thermoplastic PDE body and cover. The cover is attached via four M4 stainless steel screws with a silicon O-ring gasket. The junction box enclosure is of dimensions 117 x 117 x 65 and fitted with separately certified connection terminals. Electrical access is via separately certified cable glands fitted to holes drilled into the side and end walls of the enclosure. Refer Table 1 for power rating and temperature classification. Table 1: Model and Temperature Classification Model Number: Description: Number of entries: RTKB-1 Terminal box without fuse 3 x M20 RTKB-2 Terminal box without fuse 3 x M20 plus 2 x m25 RTKBF-1 Terminal box with E x em fuse 3 x M20 RTKBF-2 Terminal box with E x em fuse 3 x M20 plus 2 x m25 Table 2: Maximum Enclosure Configuration Maximum enclosure configuration & respective current values for a calculated maximum power dissipation not exceeding 5 W Applied max Current to respective terminal (A) Maximum number of Terminals Fitted in combination at specified applied current AKZ 1.5 AKZ 4 AKZ 1.5 AKZ 4 Fuse Type 8560 (4A) 10 22 6 7 1 10 22 12 3 1 10 20 9 6 1 10 20 12 4 1 9 20 12 6 1 8 22 12 6 1 10 16 12 7 1 7 22 12 7 1 RTKB enclosure may be fitted with any combination of terminals and fuse up to the maximum number specified with respect to the specified applied current. Table 3: Terminal & cable parameter when fitted within the RTKB enclosure Terminal type AKZ 1.5 AKZ 4 Minimum size of wiring conductor (mm 2 ) 1.5 4 Maximum Current (A) 10 22 Maximum voltage (V) 176 275 Maximum Number of terminals 12 7

NOTE : Each cable brought in and each internal connecting cable counts as a conductor. Jumpers and earthing conductors are not. When using these values account must be taken of the simultaneously factor or load to IEC 439. The use of a mixture of fittings with circuits of different cross sections is possible by pro use of the different tables. Example : from Matrix using 1.5mm / 4mm cables to add 7.0) FITTING Dimensional drawings / in mm Subject to change. Drawings are available in Rteck Industries Technical data sheets file EX09. When explosion protected equipment is exposed to the weather it is advisable to provide cover or wall protection. 8.0) INSTALLATION MAINS CONNECTION The conductors must be carefully connected The conductor insulation must reach the terminal.the conductor itself must not be damaged (nicked) when removing the insulation Note : Weidmuller AKZ4 terminal recommends 8mm stripping distance of conductor insulation. Ensure that the maximum permissible conductor temperatures are not exceeded by suitable selection of cables and means of running them PLEASE refer to the terminal details in the technical data ( Max / size conductor allowable Matrix ) SPECIAL NOTE : SAFETY 3.0 INSTALLATION REQUIREMENT To minimize the risk of electrostatic discharge. Enclosures should not be fitted where they can be subjected to high flow of Powder / dust flow that may lead to a prolific charge buildup being generated (eg) pneumatic transfer of powder or charge spraying, Clause 7.4.2 of IEC 6079.0.2011. The lid shall have the following warning label applied. WARNING Do not open when energized Potential electrostatic charging hazard EARTH connection: The earth connection must be made in all circumstances.

9.0) COMMISSIONING: Before commissioning the device ensure that: It has been correctly installed It is not damaged It contains no foreign bodies the connection area is clean the cables have been correctly brought in all screws and nuts are fully tightened the cable glands are securely tightened unused cable glands are sealed with plugs certified to IEC Ex: Ex e: Ex Td Note : Manufacturers specifications on tension 10) REPAIRS AND MAINTENANCE: Repairs and maintenance work on the devices may only be carried out by appropriately authorized and trained personal. Before work is carried out the devices must be disconnected from the mains. Observe the relevant national regulations for your country. The following points must be tested during maintenance. Clamping screw holding must be tested on maintenance Operating temperature ( by EN/ EC 60070 0 ) Cracks in plastic enclosures Damage to gaskets The device can only be cleaned with damp cloth 11) ACCESSORIES AND SPARE PARTS: Use only the original spare parts from the manufacturer. Note: The fuses fitted may only be replaced by fuses with matching characteristics. Any infringements can change the temperature class of the whole terminal box Fuse link changes may change the temperature class. Change like for like. 12) DISPOSAL: Observe the national standard for refuse disposal 13) INTERNATIONAL CERTIFICATE OF CONFORMITY IS AVAILABLE FOR UPLOAD FROM OUR WEBSITE: www.rteckpacific.com