LEM. mini-modules compact integrated vacuum pumps. US3

Similar documents
mini-modules compact integrated vacuum pumps LEM

LEM. mini-modules compact integrated vacuum pumps. US5

LEMAX. mini-modules. "ASC" compact vacuum pumps US2

Micro-venturis, series GVA

Simple venturis, series GVP

With Integral Filter and Silencer, Optional Vacuum Switch, Type VADM- Solenoid-Actuated Vacuum Generator with integral filter and silencer Type VADM-

VACUUM PUMP Midi Keyboard Pump

VACUUM PUMP P5010. Profit from new vacuum technology

Multi-Stage Ejectors. Multi-Stage Ejectors SEM. Suction rate from 332 l/min to 2,370 l/min. Suitability for Industry-Specific Applications

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm

Vacuum generation Compact ejectors

For mounting on subbase or footprint in accordance with CNOMO recommendation E 06620N Part numbers (and voltages) Voltage max. power consumption U nom

Intrinsically Safe Miniature Solenoid Valves

PROCESS & AUTOMATED VALVES

Vacuum technology Moduflex vacuum generator Peripheral module

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

COILS, CONNECTORS, SOLENOID VALVES

Control unit for valves with inflatable sealing system

Vacuum pumps/generators Small

Never Ending Innovation

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

SOLENOID VALVES AND PNEUMATIC VALVES

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS

Function Fittings. Flow Control Regulators. Piloted Function Fittings. Non-Return Valves. LIQUIfit Pressure Fittings. Other Function Fittings

Miniature Venturi Vacuum Pump with Solenoid Operated Vacuum and Blow-off

MINI-SOLENOID VALVES direct operated subbase mounted, CNOMO (15 mm width) connector size 15

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

Vacuum Automation 2.1. The future depends on good product choices

3 Porting options. for an optimized flow. 15 mm DIN For C Pilot Solenoid Valve. Stackable Valve Series - PVL-B22. PVL-B22 - Stackable Series

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

PRESSURE REGULATOR. Lucifer EPP 4 - Basic. Description. Technical data

Composite Push-In Fittings BSP/Metric Series 7000

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

Multi-Stage Air Powered Vacuum Pumps

Vacuum gripping systems Contents

System 6. ü ( System 6

DR magnetic piston. Compact Magnetic Sophisticated

Compact Proportional Solenoid Valve

Vacuum Ejector with Solid State Timer

Vacuum gripping systems Contents

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer

Chapter 11: Valves and Actuators with the NAMUR-interface

Valve Islands Series F

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

Compressed Air Conditioning. accessories. One Stop Shop process reliable efficient economical high degree of reusability

ARCAPRO positioner. Positioner customized for specific tasks

PVL-B2. Stackable and Stand-alone Inline Valves. PVL-B21 - Stand-alone Series. PVL-B22 - Stackable Series. PVL-B2 Valve Series

Vacuum pump system type

Isonic Mod 3 Series 3000/ /2, 3/2 Direct - 4/2 Single & Double Solenoid Valves

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

SBM TECHNOLOGY PET Blow Valve Block

Vacuum generators Key features

General characteristics Operating fluid Compressed air or inert gas Conditions of use Operating pressure 30 to 20 PSI (2 to 8 bars). Fluid: Filtered a

GSW-V. Application example. Special Gripper Vacuum Gripper. Weight 0.12 kg 0.39 kg. Clamping diameter 20 mm 32 mm

CONTENTS. History. Joulin s Performance. Joulin s System. Options. Questionnaire

Facts and figures INTEGRALPICKER V.

MULTI JECTOR Vacuum Pumps

Vacuum Equipment. Application. Series

SOLENOID VALVES AND PNEUMATIC VALVES

Individual, Multipole and Fieldbus

Vacuum Generators. Section B.

Keystone PremiAir Pneumatic Actuators

MINIATURE SOLENOID GENERAL SERVICE VALVES

TopControl Continuous

ema electronic Temperature Sensors Pressure Sensors Pressure Sensors Temperature Sensors Flow Sensors Smart Smart Smart

Sicher und flexibel die neue Antriebsgeneration actubar

Electro-pneumatic control valves

Innovative product solutions for vehicle automation applications

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

The Widest Range of Products for Diverse Market Applications

Series VP3145/3165/3185

Vacuum Components SHREE VYANKATESHWARA E N T E R P R I S E S

Transair: Advanced Pipe Systems Pocket Installation Guide [1/2"] [1"] [1 1/2"] [2"] [2 1/2"] [3"] [4"] [6"]

Electropneumatic pressure regulator EPP4 Series. Connection G ½. Catalogue 8684/UK G ½"

Mechanical Specifications:

Pneumatic Rack & Pinion Actuators and Accessories

INSTRUMENTATION & CONTROL

Facts and figures MULTILIFT V 6

Miniature Venturi Vacuum Pump with Pneumatic Blow-off and Silencer

Centrifugal fan with highly efficient EC drive motor

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Miniature Pneumatic Solenoid Valve

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

System 6. Solenoid Coils Armature Assemblies Valve Systems

PS1 Modular Interface Valve

Air Flow Controller M1compact Type-Summary FKM 130

Pneumatic Products st»

HL-Series Electric Actuator Precision control for linear valves

Prodigy HDLV Pump. Customer Product Manual Part A02

AMIAD "TAF" FILTER SERIES

Proximity switches and switch brackets

Facts and figures MULTILIFT SELECT 6

More Precision. mainsensor Magneto-inductive displacement sensor

Electropneumatic pressure regulator EPP4 Series

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

HERION. MINI ISO VALVES Size 18 mm, V40 / V41 SERIES Size 26 mm, V44 / V45 SERIES. Flexible subbase system with a wide range of accessories

Transcription:

mini-modules compact integrated pumps LEM TM www.coval.com US3

LEM LEM series: mini-module pressure OUT IN 2 exhaust TM certified quality management system All industrial functions integrated into the mini-module Efficient communication for easy setting, production and maintenance. www.coval.com

TM pumps A mini-module for each application: A complete line 4 basic configurations, see adjacent illustrations 2 levels : 60% and 90%. 3 standard nozzle diameters : 1, 1.2 and 1.4 mm. Air suction flow : up to 92 Nl/mn. Other options on request. with switch, display and setting with blow-off (LEM X SVA) without blow-off (LEM X RVA) with blow-off (LEM X SV0) without switch without blow-off (LEM X RV0) an efficient COMMUNICATION For settings and troubleshooting, a simple and complete communication through the means described by the adjacent illustration. blow-off / indicators blow-off / manual overrides 3 "gripped object" indicator real-time level display threshold and hysteresis settings selected setting mode display blow-off flow rate setting setting mode selection: threshold and hysteresis Mountings choice Individual mountings, close to pads or compact island association. side mounting front mounting over a DIN rail island mounting

LEM LEM series: compact functions pressure IN OUT 4 exhaust The COVAL compact integration technique The traditional venturi pumps must be completed with the optional components necessary to their functioning: solenoid valves, pressure regulator, switch, blow-off circuit, electronic control ADVANTAGES direct control 24 V DC - 0.7W -- M8 connectors, IP65 protection. One can see the advantages of a compact integration of these functions into a sole mini-module pump that becomes all inclusive. The above illustration shows the excellence of Coval in this perspective: each function type to be integrated has been redesigned, optimized and miniaturized to fit its place in the minimodule body. simplified use -- only one easy to install module; -- instant pneumatic and connections; -- plug and pay. a LEM for each application -- choice of the level and of the air suction flow; -- only necessary functions are retained. www.coval.com

TM integration INTEGRATED FUNCTIONS ➊ 3.5 bar pressure regulator ➋ Vacuum solenoid valve ➌ 3.5 bar optimized venturi ➍ Optimized muffler ➎ Electronic switch ➏ Blow-off solenoid valve ➐ Blow-off flow rate setting P network 4 to 8 bar ➊ ➋ ➌ ➍ P 3.5 bar steady blow-off ➏ ➎ ➐ The "regulator+venturi" 3.5 bar optimized combination The traditional venturi pumps must work within the defined compressed air network settings: between 4 to 8 bar, depending of the application. In the process, their efficiency and noise performances have been forsaken to meet these requirements. With the integration of the 3.5 bar pressure regulator, function as a standard, COVAL succeeded in optimizing the associated venturi for this sole pressure, thus providing two key advantages: -- an exceptional output energy savings. controlled consumption. -- a remarkably silent functioning. 5 energy savings -- The internal intelligence of the LEM modules controls the network supply pressure and helps to optimize the air consumption to 3.5 bar. This results in exceptional energy savings as shown in the figure below: silent technology -- The pressures to be exhausted to atmosphere are much lower. -- The efficiency of the optimized muffler is better. From this, results the sound level reduction shown by the bar graph below: 100 50 consumption Nl/mn traditional pumps ENERGY SAVINGS LEM pumps (nozzle 1.2 mm ID) 80 60 40 20 sound level in dba LEM pumps max. authorized level traditional generators 0 0 2 4 6 8 network pressure (bar)

LEM LEM series: dialogue intelligence blow-off / manual overrides blow-off / indicators 6 "gripped object" indicator real-time level display selected setting mode display threshold and hysteresis settings blow-off: flow-rate setting dialogue panel switch setting mode selection: threshold or hysteresis electronic mini-pcb The dialogue intelligence completes the compact functions integration The previous pages have shown the interest to integrate into a sole compact module all the functions necessary for an optional control of handling. This integration also makes possible, the compact realization of the electronic intelligence shown above: -- an electronic mini-pcb combines the switch and other electronic components required for controls and settings. -- a dialogue panel completes this by directly controlling the PCB. ADVANTAGES simple and complete communication For settings and troubleshooting, the dialogue panel gathers all the informations and access required for a complete man/machine dialogue. The machine commissioning, production and maintenance are facilitated. easy installation, protected equipment -- only one module to mount and to connect. -- sealed M8 connections; IP65 electrical protection; -- lockable dialogue panel: protection against unexpected actions. www.coval.com

TM An efficient communication at each step 1-settings At the first machine commissioning or for all evolutions the different settings are easily made. Setting of the Vacuum threshold: the level at which the switch emits the "object gripped" signal. Visual display of this setting can be observed on the LED Scale. Hysteresis setting: the reduction in the level at which the "object gripped" signal is turned off. Blow-off flow rate setting: adjustable blowoff control through screw setting or manual valve override while testing. 2-PRODUCtion Visual surveillance of functioning during each phase: rest,, blow-off. : - "" activated. - "" indicator (green) ON. - linear LED scale displays the level. - at set threshold, "gripped object" indicator and "gripped object" output signal. blow-off: - "blow-off" is emitted. - "blow-off" indicator (red) ON. - the object is released. rest: no activation signal and no display. 3-troubleshooting After any malfunctioning, troubleshooting is quickly made. Automatic check At each return to tension, automatic check of the electronic functions: switch, displays, settings SETTING threshold "" ordered TROUBLESHOOTING automatic check threshold setting mode gripped object blinks if defect LED display + setting - setting mode selection real-time level display all electronic functions are checked 7 Stand-alone or island modules? Stand-alone modules are suitable for the most common applications; one module controls one or more suction pads which all operate according to the same sequence. When several suction pads are operating according to different sequences, multiple modules are required, which can be: - several stand-alone modules, OR - an island of these modules with an internal common pressure unit. The adjacent illustrations help in the selection: - Stand-alone modules are complete, with the integrated pressure regulator. - In an island, the integrated regulator is absent: to maintain the advantage of economical and silent operation, it is recommended to reduce the pressure to the island's common pressure unit to 4 bar. Characteristics and connecting an island Torx T8 1/8" BSP Torx T8 set of ends for island Network pressure 4 to 8 bar 3.5 bar regulator stand-alone module common pressure unit P optimal = 4 bar (operation at 4-8 bar) island of 3 modules supplying suction pads according to different sequences Maximum number of modules in an island: Ø 1.4 mm nozzle 5 modules. Ø 1.2 mm nozzle 7 modules. Ø 1.0 mm nozzle 9 modules.. Note: in the same island, it is possible to combine LEM series modules and LEMAX series modules. Island of 4 modules grouping screw common pressure unit plug

Ref. composed of an assembled island or components for Ref. composed of a stand-alone module LEM 90 X 12 air supply P=4 to 8 bar, 6mm OD tubing VACUUM LEVEL 90% max. optimum for air tight products 60% max. optimum for porous products 90 60 NOZZLE diameter 10 nozzle 1.0mm ID 12 nozzle 1.2mm ID 14 nozzle 1.4mm ID 8 : 8mm OD tubing VENTURI CHARACTERISTICS 1- Maximum level This level results from the venturi mixer's profile: -- 90% max. is optimum for air tight products. -- 60% max. is optimum for porous products. 2- Nozzle diameter It reflects the air suction flow, but also the power consumption. Thus it must be chosen for the specific need, without excess. nozzle diameter nozzle mixer venturi atm. p. atm. p. atm. p. vide atm. p. atm. p. Air tight products handling: glass, plastic, coated wood, metal sheet Because leaks are limited, the level to be used may be high: between 50 to 80%, to be generated by a 90% max. level venturi. 90% max. LEM Emptying time (seconds) for 1 liter volume reached 55% 60% 65% 70% 75% 80% nozzle ID Porous products handling: cardboard, raw wood, pastries Significant porosity and/or surface leaks are to be expected. For handling, a level between 30 to 55% is the best compromise, to be generated by a 60% max. level venturi. 60% max. LEM Taking into account the volume to be emptied and the response time to do so, the chart below is a guide towards the most economical nozzle and gives the air suction flow. Air consumption (Nl/mn) Air suction (Nl/mn) 1.0 mm 1.76 2.04 2.38 2.80 3.33 4.09 44 29 1.2 mm 1.13 1.31 1.53 1.80 2.15 2.64 65 45 1.4 mm 0.73 0.85 0.99 1.16 1.38 1.70 90 70 The chart below is a first indication towards the most economical nozzle ID, to be completed by a leak flow product measurement. Emptying time (seconds) for 1 liter volume reached 30% 35% 40% 45% 50% 55% nozzle ID Air consumption (Nl/mn) Air suction (Nl/mn) 1.0 mm 0.66 0.83 1.04 1.31 1.70 2.35 44 38 1.2 mm 0.41 0.52 0.66 0.83 1.07 1.49 65 72 1.4 mm 0.27 0.34 0.43 0.54 0.70 0.97 90 92 www.coval.com

an island to be assembled S V A B3 R S module composition Simple pump without blow-off: LEM X RV_ Only one control signal. NC control valve. Vacuum pump with controlled blow-off: LEM X SV_ 2 control signals. NC control valve. Blow-off controlled by external signal (NC control valve ) with adjustable flow rate. VA VACUUM SWITCH / dialogue PANEL Electronic switch with display and setting Separate settings for threshold and hysteresis. Real-time level display. "Gripped product" indicator. M8 connectors for inputs and outputs.switching output and analogic output.electrical protection: IP65. B2 B3 B4 B island assemblies LEM X B2 island assembly with 2 identical modules LEM X B3 island assembly with identical modules If the planned island contains different module types, it must be delivered as separate components in order to then be assembled on site according to the arrangement suitable to the application. components for the island to be ASSEMBLED LEM X B Module that can be grouped (complete with integrated grouping screw). 9 U V Simple pump without blow-off: LEM X UV_ Only one control signal. NO control valve. Vacuum pump with controlled blow-off: LEM X VV_ 2 control signals. NO control valve. Blow-off controlled by external signal (NC control valve ) with adjustable flow rate. VO No switch Automatic functioning up to maximum level (no setting and no display). M8 connector for inputs only. Electrical protection: IP65. Example composite part number for an island assembly: nnlem60x14svab3 LEM island assembly, containing 3 x 60% max. modules, ø 1.4 mm nozzle, controlled by NC solenoid valve, blow-off and switch. Order example for an island to be assembled: nnlem60x10vvab 3 LEM modules for a group, of nnlem90x12svab different types. nnlem60x14svab nnlemseta Set of ends for a complete group, with grouping screw and common pressure unit plug. REF: LEMSETA Set of ends for island. Reference example composed of a standalone module: nnlem60x12sva Stand-alone LEM Module, 60% max., ø 1.2 mm nozzle, controlled by NC solenoid valve, blow-off along with switch.

LEM series: mounting options 1- Stand-alone modules SIDE MOUNTING M8 connector Ø6 The side mounting is the simplest of all: 2 protruding screws. 13.5 18.5 2 connecting screws or bolts, Ø 4mm 64.5 2 screw holes 4mm Dia. 32.5 2 large washers Ø8 26 25 59.5 FRONT MOUNTING screw 4mm Dia. For fixing from front, please order the necessary kit in addition to the ejector module: Individual fixing plate with 4 fixing screws 75 85 2 fixing screws 4mm Dia. Kit for fixing from front : 1 plate + 4 screws REF: LEMFIXA 10 screw 4mm Dia. 15 61 25 MOUNTING ON DIN RAIL individual mounting plate over DIN rail with 4 fixing screws 26 26 A module can be clipped onto a DIN rail. 70.2 DIN rail 29.9 35 6.7 64.5 71.2 For this purpose, the module must first be equipped with an individual DIN installation plate, ordered separately: DIN rail mounting kit: 1 plate/clip + 4 screws REF: LEMFIXB 2- Islands 25 x n LEM + 40 25 x n LEM + 20 FRONT MOUNTING 37 59 MOUNTING ON DIN RAIL 66.5 59 0.5 64.5 25 15 24.5 64.5 7.5 35 22 clip DIN 20 25 20 26 33.5 www.coval.com 4 optional holes for 2 Ø 4mm screws 2 optional holes for 1 Ø 4mm connecting screw, at each end of the island DIN rail mounting kit: 2 clips + 4 screws REF: LEMFIXC

TM LEM series: characteristics General characteristics C.A supply 5µ filtered, non-lubricated air relevant to ISO 8573-1 class 4 standard. Optimal working pressure: 4 to 8 bar. Blow-off: network supply pressure, adjustable flow rate. Maximum : 60% or 90% according to model (see page 8). Suction flow rate: 29 to 92 NL/min according to model (see page 8). Air consumption: from 44 to 90 NL/min according to model. Electric degree of protection: IP65. Voltage tension: 24 V DC (adjustable +- 10%). Current draw: 30 ma (0,7W) or blow-off. Maximum frequency of utilization: 4 Hz. Number of operations: 10 million cycles. Weight: from 80 to 120 g according to model. Working temperature: from 10 C to 60 C or 50 F to 140 F. Materials: PA 6-6 15% FG, brass, aluminum, NBR. Electrical connections MODULES WITHOUT VACUUM SWITCH M8 inputs 24 V DC 2 4 1 3 24 V DC blow-off Integrated switch Adjusting range: -1 to 0 bar. Precision: ± 1, 5 % of the range. Hysteresis: from 0% to 100% (adjusted by potentiometer). Output threshold: 1 x switching output, NO. Analogic output: from 1 V DC over the measuring range. Switching power: 125 ma PNP. Threshold state display : 1x LED green Power supply: 24 V DC (regulated ± 10%) Current draw: < 20 ma. Protection: against the inversions of polarity. Integrated silencer Sound level: 68 dba. Clog free silencer. MODULES WITH VACUUM SWITCH analogic output 1 to 5 V DC 2 4 1 3 switching output 24 V DC outputs inputs 24 V DC 2 4 1 3 24 V DC blow-off 0 V 24 V DC 0 V 0 V 11 LEM series: applications The LEM series mini-module pumps offer a new approach to handling in numerous domains: packaging, robotic, clamping, transfers, plastic molding, etc, Optimized to serve small and medium sized suction pads, LEM helps to simplify the installation while integrating all control functions into a single light weight mini-module, placed close to the suction pads. In technical traditions, only the venturi and the switch are compact enough to be installed close to the suction pads. Further, they should be supplemented by solenoid valves, a pressure regulator, an electronic control which also need to be installed and fitted resulting in a laborious, expensive and complex installations. A single block of LEM series mini module is enough to solve these well known problems. Thanks to its light weight, compact design and complete functions, the LEM mini-modules can be installed at the suction pads. Additionally, as explained in the previous pages, the LEM also offers new energy savings, an exceptional silent functioning, and at last the dialogue intelligence needed for easy settings, follow up and maintenance. Packaging machines ROBOTIC HANDLING TOOLS LEM, the unparalleled progress in handling technology CLAMPING PLASTIC INDUSTRY

A TECHNOLOGICAL PARTNER ON A GLOBAL SCALE Located in the southeast region of France, COVAL conceives, manufactures and globally distributes high performance, advanced automation components and systems for industrial applications in all branches. COVAL is an ISO 9001: V2008 certified company which offers innovative solutions integrating reliable and optimized components with intelligent functionalities. The focus is to provide the most personalized and economic solution to a given application while assuring a significant improvement in the productivity and the safety for the users around the world. COVAL has an ambition for technical excellence and innovation. As a specialist in automation, COVAL is reputed for offering reliable, personalized, cost effective and productive solutions. Distributed by: The references of COVAL can be found in several industrial sectors (Packaging, Automotive Industry, Plastic, Graphic, Aeronautic ) where handling is important for high efficiency and productivity. COVAL markets its products and services all over Europe, in the United States and South America through its subsidiaries and authorized distribution network. COVAL strives to provide customer driven solutions and gives the best possible treatment to satisfy all its clients. For all enquiries from Australia, Africa and Asia kindly contact COVAL head office in France. certified quality management system COVAL VACUUM TECHNOLOGY INC. 212-112 Powell Drive Raleigh, NC 27606 Phone : (919) 233-4855 Fax : (919) 233-4854 COVAL 07/2012 illustrations KeyOx The diagrams are not contractual. The range and the products characteristics may be modified by COVAL without notice. www.coval-inc.com