Motor Starter Protectors

Similar documents
Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

Protection Equipment. 5/2 Introduction

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Protection Equipment

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

SIRIUS 3RU2 Thermal Overload Relays

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

Protective Devices: Circuit-Breakers 1 )

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

3VF3 to 3VF8 Circuit-Breakers

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

BETA Switching Switches and Light Indicators

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Control Circuit Protection

Manual Motor Starters. Meta-MEC

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

General data 5/37. Overview

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Industry Automation Control Components

3NP1 Fuse Switch Disconnectors up to 630 A

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

Selection Guide Motor Control Device Solutions

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Motor Controllers + Circuit Breakers

XT IEC Power Control Manual Motor Protectors

Industrial Controls. Load Feeder. Configuring SIRIUS Innovations Selection data for Fuseless and Fused Load Feeders. Configuration Manual 04/2011

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

3VU13, 3VU16 Circuit-Breakers

System Manual 02/2008

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

3RW Soft Starters. General data. 6/4 Siemens LV

For Operation in the Control Cabinet

Phone: Fax: Web: -

DEVICE STATE/BYPASSED FAILURE OVERLOAD

PKZ and PKE motor-protective circuit-breakers

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

For Operation in the Control Cabinet 3RW Soft Starters

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

AF40... AF96 3-pole contactors Technical data

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Motor protective circuit breakers

Series KTU7 UL489 Molded Case Circuit Breakers

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

smissline Description

C E R T I F I C A T E O F C O M P L I A N C E

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Partnership that you can trust. LV Switchgear Motor Control Products.

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

3RT14 Contactors with 3 Main Contacts

C E R T I F I C A T E O F C O M P L I A N C E

FMotor Circuit Controllers

KT4 Manual Motor Starter

Series KTU7 UL489 Molded Case Circuit Breakers

SIRIUS Configuration

SIRIUS Shortform Catalogue 2017 siemens.com/sirius

Motor Circuit Breakers C4

Short-Circuit Current Ratings

Industrial Controls. Load Feeders. Configuring the SIRIUS Modular System Selection data for Fuseless and Fused Load Feeders. Configuration Manual

Combination Starters. SIRIUS 3RA11 Non-Reversing Combination Starters,

A302DN.40/.63A Thermal Current Motor Starter

Short form catalogue Motor protection and control Manual motor starters

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

Short form catalogue. Motor protection & control

Order No. of the options EMC filter Class A

SENTRON VL Series Product Specifications

Motor Circuit Breakers C3

3VT1 Molded Case Circuit Breakers up to 160 A

22AF 40AF AF 150AF 225AF 400AF 800AF

SIRIUS 3RV2 motor starter protectors. Electrical Components for the Railway Industry

8WH2 Spring-Loaded Terminals

References 4 Fuse carriers

3VT Kompaktleistungsschalter bis 630A

Electrical Components for the Railway Industry. SIRIUS 3RV2 motor starter protectors

UMBW-UL489 and UL1077 Listed

Ideal for use as a manual starter

SENTRON Switching and Protection Devices Switch Disconnectors

C E R T I F I C A T E O F C O M P L I A N C E

Technical specifications

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Page 2-4 Page 2-8. Page Page 2-13

D509E. Manual Motor - Starters

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Transcription:

Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker UL 489 /6 Accessories Auxiliary Switches /7 Auxiliary Releases /7 Busbars /8 Mounting Accessories /9 - / Rotary Operating Mechanisms /3 Enclosures & Front Plates /3 3RV9 Infeed System /4 - /7 for Motor Starter Protectors Manual Motor Starter Ratings /8 Group Installation Ratings /9 Combination Motor Controller Ratings /0 3RV7 and 3RV8 Circuit Breaker Ratings / Export Application Ratings / - /3 Rules for Mounting /4 Technical Data / - /8 Overview of MSP Functions & Applications /9 Application as a Combination Motor Controller /30 Application in DC Switching /3 Design /3 Characteristics /3 Circuit Diagrams /3 Dimensions /33 - /34 for Accessories Mountable Accessories Overview /3 - /36 Circuit Diagrams /37 - /3 Dimensions /38 Busbar Accessories Overview /39 Dimensions /40 - /4 Operating Mechanisms Overview /4 Circuit Diagrams /43 Dimensions /43 - /44 Enclosures & Front Plates Overview /4 Dimensions /46 Spring Terminal Infeed System Design /47 Technical Data /47 Dimensions /48 Siemens Canada Limited Industrial Control Product Catalog 09 /

IEC Power Control Motor Starter Protectors contents 3RV motor starter protectors up to 00 A Size S00, S0 For motor protection CLASS 0 Selection and ordering data Size Rated Current Page S00 up to 6 A /4 S0 up to 40 A /4 S up to A / S3 up to 00 A / For motor protection CLASS 0 Selection and ordering data Size Rated Current Page S up to A / S3 up to 00 A / General data for motor starter protectors Page Technical data /8 Overview /8 Characteristics /3 Circuit diagrams /3 Dimension drawings /33 Circuit Breakers 3RV7, 3RV8 3RV9 infeed system 3RV MSP auxiliaries and accessories Page Selection and ordering data /6 Page Selection and ordering data /6-/7 Dimension drawings /34 Technical data /47 Overview /4-/ Dimension drawings /48 Selection and ordering data /7-/8 Page Technical data /7 Overview /3 Circuit diagrams /37 Dimension drawings /38 / Siemens Canada Limited Industrial Control Product Catalog 09

IEC Power Control Accessories contents 3RV busbar and accessories Accessories for motor starter protectors with Spring-Type terminals Mounting Accessories Page Selection and ordering data /8 Page Selection and ordering data /7 Page Selection and ordering data /9 -/ Overview /39 Technical data /40 Technical data /8 Overview /36 Technical data /38 Rotary operating mechanisms Enclosures and front plates Page Selection and ordering data /3 Technical data /8 Overview /4 Circuit diagrams /43 Dimension drawings /43 Page Selection and ordering data /3 Overview /4 Dimension drawings /46 Siemens Canada Limited Industrial Control Product Catalog 09 /3

For Motor Protection 3RV0 Class 0 up to 40A Description The 3RV0x MSPs are UL approved as Self Protected Combination Motor Controllers which are also called Type E. In this application, all the required functions for a motor branch are provided in one device: disconnect, short circuit protection, motor control and overload protection. A type E terminal adaptor is required. The 3RV0x MSPs are also approved for use as follows: Manual Motor Controller: Motor starter, motor disconnect, control and overload protection. Group Installation: Motor starter only, motor disconnect, control and overload protection. Tap conductor Protection in Group Installation acc. NEC: Motor starter only; motor disconnect, control and overload protection. When the 3RV0x is used with one of the 3 above mentioned approvals, the 3RV0x can be installed downstream of one circuit breaker or fuse set. For more detailed application information and rules how to apply, size and rate the 3RV0x in control panels in general, in group installations or in accordance to international IEC standards visit our website: www.usa.siemens.com/controlpaneldesign Ordering Information E ON/OFF rotary handle with lockout and visible trip indication. E Adjustment dial for setting to motor FLA. E Class 0 overload trip characteristics. E Short circuit trip at 3 times the maximum setting of the FLA adjustment dial. E Short circuit current rating: E Ambient compensated up to 40 F (applies to side by side mounting). E Phase loss sensitivity. E Test trip function. E Terminal versions: screw, spring, ring lug. E Auxiliaries and Accessories see pages /7 /7. E General Information see pages /9 /3. E Technical Data see pages /8 /8. E Dimensions see page /33. Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only. Illustration FLA Adjustment Range [A] 0.-0.6 0.4-0. 0.8-0. 0.-0.3 0.8-0.4 0.3-0. 0.4-0.63 0.-0.8 0.7-0.9-..-.6.4-.8-..-3..8-4 3.- 4.-6.3.-8 7-0 9-. 0-6 3-0 6-8- 3-8 7-3 30-36 3) 34-40 3) 9-. -6 4-0 7-0- Single-Phase HP Ratings Three-Phase HP Ratings ) V 30V 00V 30V 460V 7V 0 8 6 ¼ ¼ 3 ½ ¾ ½ ½ 3 3 ½ ½ ½ 0 6 ¼ 3 ½ ½ ¾ ½ 3 3 3 7 ½ ½ 3 3 3 ½ ¾ ½ 3 3 7 ½ 7 ½ 7 ½ 7 ½ 0 0 0 3 3 7 ½ ½ ½ ¾ ½ 3 3 7 ½ 7 ½ 7 ½ 0 0 0 0 3 7 ½ 7 ½ ½ ½ ¾ ½ 3 3 7 ½ 7 ½ 0 0 0 0 30 7 ½ 0 0 ½ ½ ¾ ½ 3 3 7 ½ 0 0 0 0 0 0 Instantaneous short circuit release [A]..6 3.3 4.. 6. 8. 0 3 6 6 33 4 8 04 30 63 08 60 86 3 364 400 43 480 63 08 60 86 3 UL shortcircuit breaking capacity @ 480V [ka] 0 0 30 30 30 30 30 ) 4) Size S00 ) 4) Size S0 Order Number Order Number 3RV0-0AA 3RV0-0BA 3RV0-0CA 3RV0-0DA 3RV0-0EA 3RV0-0FA 3RV0-0GA 3RV0-0GA 3RV0-0HA 3RV0-0HA 3RV0-0JA 3RV0-0JA 3RV0-0KA 3RV0-0KA 3RV0-AA 3RV0-AA 3RV0-BA 3RV0-BA 3RV0-CA 3RV0-CA 3RV0-DA 3RV0-DA 3RV0-EA 3RV0-EA 3RV0-FA 3RV0-FA 3RV0-GA 3RV0-GA 3RV0-HA 3RV0-HA 3RV0-JA 3RV0-JA 3RV0-KA 3RV0-KA 3RV0-4AA 3RV0-4AA 3RV0-4BA 3RV0-4CA 3RV0-4DA 3RV0-4NA 3RV0-4EA 3RV0-4PA 3RV0-4FA 3RV03-KA ) 3RV03-4AA ) 3RV03-4BA ) 3RV03-4CA ) 3RV03-4DA ) Screw terminals, no auxiliary: = 0 Screw Terminals, with NO/NC Aux: = Spring terminals, no auxiliary: = 0 Spring Terminals, with NO/NC Aux: = Ring Lug Terminals, no Auxiliary: = 40 ) Select motor starter protector by motor full load amps. Horsepower ratings for reference only. ) The motor starter protectors rated up to 3 A can be used as manual motor controllers or as Type E combination motor controllers. For use as a Type E combination motor controller, a Type E terminal is required. See accessories page /0. 3) These products are NOT certified as Type E combination motor controllers. They can only be used as manual motor controllers. 4) 3RV MSPs can only be used with Innovations contactors and accessories ) Available only with = 0, or = 0 /4 Siemens Canada Limited Industrial Control Product Catalog 09

For Motor Protection 3RV0 Class 0 & 0 up to 00A Description The 3RV03 / 04 MSPs are UL approved as Self Protected Combination Motor Controllers which are also called Type E. In this application, all the required functions for a motor branch are provided in one device: disconnect, short circuit protection, motor control and overload protection. A type E terminal adaptor is required for all S frame 3RV03 above 4A and all S frame 3RV03 as well as for all S3 frame motor starter protectors. The 3RV03 / 04 MSPs are also approved for use as follows: Manual Motor Controller: Motor starter, motor disconnect, control and overload protection. Group Installation: Motor starter only, motor disconnect, control and overload protection. Tap conductor Protection in Group Installation acc. NEC: Motor starter only; motor disconnect, control and overload protection. When the 3RV03 / 04 is used with one of the 3 above mentioned approvals, they can be installed downstream of one circuit breaker or fuse set. For more detailed application information and rules how to apply, size and rate these MSPs in control panels in general, in group installations or in accordance to international IEC standards visit our website: www.usa.siemens.com/controlpaneldesign Ordering Information E ON/OFF rotary handle with lockout and visible trip indication. E Adjustment dial for setting to motor FLA. E Class 0 overload trip characteristics. E Short circuit trip at 3 times the maximum setting of the FLA adjustment dial. E Short circuit current rating: E Ambient compensated up to 40 F (applies to side by side mounting). E Phase loss sensitivity. E Test trip function. E Auxiliaries and Accessories see pages /7 /7. E General Information see pages /9 /3. E Technical Data see pages /8 /8. E Dimensions see page /33. Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only. Illustration FLA Adjustment Range [A] Single Phase HP rating ) 3 Phase HP Rating ) V 40V 00V 30V 460V 7V Inst. Short- Circuit Release [A] UL AIC (480V) [ka] 6) Trip Class 0 Order Number 4) Trip Class 0 Order Number 4) 3RV03 Frame Size S 9. - 4. 3 0 08 3RV03-4SA0 3RV03-4SB0-7. 3 7. 60 3RV03-4TA0 3RV03-4TB0 4-0. 3 7. 7. 0 60 3RV03-4BA0 3RV03-4BB0 8-7. 0 0 3 3RV03-4DA0 3RV03-4DB0-3 3 0 0 30 46 3RV03-4EA0 3RV03-4EB0 8-36 3 7. 30 40 0 3RV03-4PA0 3RV03-4PB0 3-40 3 7. 30 40 8 3RV03-4UA0 3RV03-4UB0 3-4 3 0 40 0 0 3RV03-4VA0 3RV03-4VB0 4-0 0 40 0 74 3RV03-4WA0 3RV03-4WB0 49-9 0 0 60 84 30 3RV03-4XA0 3RV03-4XB0 4-0 0 60 84 30 3RV03-4JA0 3RV03-4JB0 6-73 7. 30 60 7 949 0 3RV03-4KA0 3RV03-4KB0 70-80 7. 30 60 7 040 0 3RV03-4RA0 3RV03-4RB0 3RV04 Frame Size S3 8-40 3 7. 30 40 0A 3RV04-4FA0 3RV04-4FB0 36-0 0 0 40 0 0A 3RV04-4HA0 3RV04-4HB0 4-63 0 0 60 89A 3RV04-4JA0 3RV04-4JB0 7-7 7. 60 7 97A 3RV04-4KA0 3RV04-4KB0-84 7. 30 60 7 70A 3RV04-4RA0 3RV04-4RB0 7-93 7. 0 30 40 7 00 3) 300A 3RV04-4YA0 3RV04-4YB0 80-00 0 40 40 7 00 3) 300A 3RV04-4MA0 3RV04-4MB0 ) Select motor starter protector by motor full load amps. Horsepower ratings for reference only. ) Size S and S3 are listed as type E combination motor controllers. For required Type E terminals see page /0. 3RV03 MSPs with a current setting limit of 4A or less do not require a type E terminal and fulfill the spacing requirements of UL08. 3) Shaded ratings apply for group installation only. These ratings do not apply as UL listed manual combination starters. 4) Pre-assembled motor starter protector and transverse auxiliary switch with NO + NC is available. Replace the last digit of the order no. with a. ) 3RV MSPs can only be used with 3RT contactors and accessories. 3RV MSPs can only be used with 3RT contactors and accessories. 6) For 00kA SCCR rated MSPs, change the part number from 3RV03 to 3RV03. (applies to S frame only through A). Refer to pages /8 to /0 when using an MSP in a Manual Motor Starter or a Manual Self-Protected Combination Motor Controller. Siemens Canada Limited Industrial Control Product Catalog 09 /

3RV Circuit Breakers UL 489 3RV up to 70 A Selection and ordering data Rated Current ) [A] Thermal overload release (non-adjustable) [A] Short Circuit breaking capacity [ka] 480 VAC 480Y/ 77VAC 600Y/ 347VAC For Motor Protection ) Instantaneous Over Current Release [A] Order Number (Screw Terminals) Weight [kg] For Transformer Protection 3) Instantaneous Over Current Release [A] Order Number (Screw Terminals) Innovations Frame Size S00 4) 0.6 0.6 0. 3RV7-0AD0 0.390 3.3 3RV8-0AD0 0.390 0. 0. 0.6 3RV7-0BD0 0.390 4. 3RV8-0BD0 0.390 0. 0. 0 3.3 3RV7-0CD0 0.390. 3RV8-0CD0 0.390 0.3 0.3 0 4. 3RV7-0DD0 0.390 6. 3RV8-0DD0 0.390 0.4 0.4 0. 3RV7-0ED0 0.390 8. 3RV8-0ED0 0.390 0. 0. 0 6. 3RV7-0FD0 0.390 0 3RV8-0FD0 0.390 0.63 0.63 0 8. 3RV7-0GD0 0.390 3 3RV8-0GD0 0.400 0.8 0.8 0 0 3RV7-0HD0 0.390 6 3RV8-0HD0 0.40 0 3 3RV7-0JD0 0.40 3RV8-0JD0 0.40.. 0 6 3RV7-0KD0 0.40 6 3RV8-0KD0 0.460.6.6 0 3RV7-AD0 0.460 33 3RV8-AD0 0.460 0 6 3RV7-BD0 0.460 4 3RV8-BD0 0.460.. 0 33 3RV7-CD0 0.460 3RV8-CD0 0.460 3. 3. 0 4 3RV7-DD0 0.460 3RV8-DD0 0.460 4 4 0 3RV7-ED0 0.40 8 3RV8-ED0 0.460 0 3RV7-FD0 0.460 04 3RV8-FD0 0.460 6.3 6.3 0 8 3RV7-GD0 0.460 30 3RV8-GD0 0.460 8 8 0 04 3RV7-HD0 0.460 63 3RV8-HD0 0.460 0 0 0 30 3RV7-JD0 0.460 08 3RV8-JD0 0.460.. 0 63 3RV7-KD0 0.460 60 3RV8-KD0 0.460 08 3RV7-4AD0 0.470 86 3RV8-4AD0 0.470 Innovations Frame Size S0 4) 0 0 0 60 3RV7-4BD0 0.4 3 3RV8-4BD0 0.6 0 86 3RV7-4CD0 0.6 364 3RV8-4CD0 0.8 Innovations Frame Size S3 ) 0 0 0 0 3RV74-AD0 0.460 0 3RV74-BD0 0.460 0 0 0 60 3RV74-CD0 0.460 0 3 3RV74-DD0 0.460 30 30 0 390 3RV74-ED0 0.460 3 3 0 4 3RV74-FD0 0.460 40 40 0 0 3RV74-GD0 0.460 4 4 0 8 3RV74-HD0 0.460 0 0 0 0 3RV74-JD0 0.460 60 60 0 780 3RV74-LD0 0.460 70 70 0 90 3RV74-QD0 0.460 Weight [kg] ) 00 % rated value acc. to UL 489 and IEC 60947- (00 % rated breaker). ) Circuit breakers for system protection of motor and non-motor loads. Requires use of separate overload protection for motor applications. 3) Circuit breakers for system and transformer protection according to UL/CSA. Specially designed for transformers with high inrush current. 4) Transverse and lateral auxiliary switches can be ordered separately (see Mountable accessories ). ) Transverse auxiliary switches must not be mounted. Lateral auxiliary switches can be ordered separately (see Mountable accessories ). Refer to page / when using as upstream protection of a Manual Motor Controller or a Manual Motor Controller Suitable for Tap Conductor Protection in Group Installations. /6 Siemens Canada Limited Industrial Control Product Catalog 09

Accessories Auxiliaries and Accessories Selection and ordering data Type Version Width Fits 3RV Frame Size Innovations Screw Connection Order No. Auxiliary switches 3) mm Innovations 3RV90-E Transverse auxiliary switches CO NO + NC NO S00, S0, S, 3RV90-D S3 ), ) 3RV90-E ) 3RV90-F 3RV90-G 3RV90-A Solid-state compatible, transverse auxiliary switches for use in dusty atmosphere and in electronic circuits with low operating currents CO S00, S0, S, S3 3RV90-G Covering caps for transverse auxiliary switch slots (pack of 0) S00, S0, S, S3 3RV90-0H Signaling switch 4) 3RV9-M Lateral auxiliary switches (side mount) Width = 9 mm Signaling switch (side mount) Individual tripped and short-circuit signaling NO + NC NO NC NO + NC NO + NC each 9 9 9 8 S00, S0, S, S3 8 S00, S0, S, S3 ), ) 3RV90-A ) 3RV90-B ) 3RV90-C 3RV90-J Innovations ), ) 3RV9-M Width = 8 mm Auxiliary releases ) 3RV90-AB4 Undervoltage releases (side mount) Width = 8 mm DC 4 V AC 0 Hz 4 V 0 V 30 V 400 V 4 V 00 V AC 60 Hz 0 V 08 V 40 V 440 V 480 V 600 V S00, S0, S, S3 Innovations 3RV90-AB4 S00, 3RV90-AB0 S0, S, 3RV90-AF0 S3 ), ) 3RV90-AM ), ) 3RV90-AP0 3RV90-AV0 3RV90-AV 3RV90-AS0 Undervoltage releases with leading auxiliary contacts NO (side mount) Width = 8 mm Shunt releases (side mount) Width = 8 mm 30 V 400 V 4 V 30 V 400 V 4 V 40 V 440 V 480 V 40 V 440 V 480 V AC 0/60 Hz 00% ON 6) AC 0/60 Hz sec ON 7) 0-4 V 0-70 V 90-0 V 70-90 V 0-40 V 90-330 V 30-4 V 330-00 V 00 V 00 V S00, S0, S, S3 S00, S0, S, S3 S00, S0, S, S3 ) 3RV9-CP0 ) 3RV9-CV0 ), ) 3RV9-CV ) 3RV9-CP0 ) 3RV9-CV0 ), ) 3RV9-CV ), ) 3RV90-DB0 ), ) 3RV90-DF0 ) 3RV90-DP0 3RV90-DV0 3RV90-DS0 ) This product is also available with spring terminals. The order no. must be changed in the 8th position to a :e.g. 3RV90-E or 3RV90-E ) This product is also available with ring lug terminals. The order no. must be changed in the 8th position to a 4 : e.g. 3RV90-4E 3) Each motor starter protector can be fitted with one transverse and one lateral auxiliary switch. The lateral auxiliary switch NO + NC is used without transverse auxiliary switch. 4) One signaling switch can be mounted at the left of the motor starter protector. This accessory cannot be used on the 3RV7 and 3RV8 circuit breakers. ) One auxiliary release can be mounted at the right of each MSP. motor starter protector. 6) The response voltage at the lower limit of the voltage range at 0.8 (Tu=60 C) is valid for 00% (infinite) 7) The response voltage at the lower limit of the voltage range at 0.9 (Tu=60 C) applies for a duty cycle of seconds at AC 0/60 Hz and DC. Siemens Canada Limited Industrial Control Product Catalog 09 /7

Accessories Mounting accessories Selection and ordering data 3RV9 3-3C unit 0.369 ) Not suitable for 3RV UL 489 circuit breakers. 3) Auxiliary trip units and lateral auxiliary switches cannot be used in combination. Modular spacing Number of motor starter protectors that can be connected Without lateral accessories Incl. lateral auxiliary switch With auxiliary trip unit Rated current I n at 690 V For motor starter protectors Size ) Not suitable for 3RV motor starter protectors with overload relay function. The 3RV9-DB connecting piece is available for connecting motor starter protectors from size S0 to size S00. Order No. Order quantity Weight approx. mm A kg Three-phase busbar systems for Classic and Innovations For feeding several motor starter protectors with screw terminals, mounted side-by-side on standard mounting rails, insulated, with touch protection. 3RV9 -AB 4 -- -- 63 S00, S0 )) 3RV9 -AB unit 0.044 )) 3 S00, S0 3RV9 -BB unit 0.07 4 )) S00, S0 3RV9 -CB unit 0.099 )) S00, S0 3RV9 -DB unit 0.4 3RV9 -BB -- -- 63 S00, S0 )) 3RV9 -AB unit 0.048 )) 3 S00, S0 3RV9 -BB unit 0.079 4 )) S00, S0 3RV9 -CB unit 0. )) S00, S0 3RV9 -DB unit 0.40 3RV9 -CB 63 -- -- 63 S00, S0 )) 3RV9-3AB unit 0.0 4 S00, S0 )) 3RV9-3CB unit 0.0 -- -- 08 S3) 3RV9 3-A unit 0.0 3 S3) 3RV9 3-B unit 0.4 4 S3) 3RV9 3-C unit 0.9 3RV9 -DB 7 -- 08 S 3RV9 3-3A unit 0.6 3 3 S 3RV9 3-3B unit 0.6 4 4 S Version Modular spacing For motor starter protectors Size Order No. mm Connecting pieces for three-phase busbars For Innovations For connecting three-phase 4 S00, S0 3RV9 -DB busbars for motor starter 3RV9 -DB protectors of size S0 (left) to size S00 (right) Conductor cross-section, AWG cables, solid or stranded For 3RV MSP For 3RV MSP Tightening torque For motor starter protector size 3RV Innovations ) AWG AWG Nm Order No. Three-phase feeder terminals 3RV9 -AB Connection from top 0 4 3 4 S00 3RV9-AB 0 4 3 4 S0 3RV9-AB 3RV9-B Connection from below 3) 0 4 Input: 4, S00, S0 3RV9-B Output:.... 3RV93-A Connection from top 4...0 -- 4-6 S 3RV93-A Order quantity Weight approx. kg unit 0.04 Three-phase feeder terminals for constructing Type E Starters Innovations 3RV93-E Connection from top 0 4 3-4 S00 3RV9-EB 0 4 3-4 S0 3RV9-EB 8...0 0.../0 4.-6 S 3RV93-E ) Do not mix 3RV Classic Accessories with 3RV Innovations MSPs ) Do not mix 3RV Innovations Accessories with 3RV Classic MSPs 3) This terminal is connected in place of a switch, please take the space requirement into account. /8 Siemens Canada Limited Industrial Control Product Catalog 09

Accessories Mounting accessories Overview Accessories for "Self-Protected Combination Motor Controllers (Type E)" according to UL 08/UL 60947-4- The 3RV0 motor starter protectors with screw terminals are approved according to UL 08/UL 60947-4- as "Self-Protected Combination Motor Controllers (Type E)". This requires increased clearance and creepage distances ( inch and inches respectively) at the input side of the device, which are achieved by mounting a terminal block or a phase barrier. 3RV98-H terminal block 3RV938-K phase barrier Motor starter protectors/ circuit breakers -- No accessories needed Note: Size NSB0_0379c IC0_00408 Essential accessories for "Self-Protected Combination Motor Controllers (Type E)" according to UL 08/UL 60947-4- 3RV0., 3RV0. S00/S0 3RV98-H terminal block or 3RV98-K phase barrier 3RV03-4B., S -- 3RV03-4D.., 3RV03-4E., 3RV03-4P.., 3RV03-4S.., 3RV03-4T.., 3RV03-4U.., 3RV03-4V.. 3RV03-4J.., 3RV03-4K.., 3RV03-4R.., 3RV03-4W.., 3RV03-4X.., 3RV03 S 3RV938-K phase barrier 3RV04 S3 3RT946-4GA07 terminal block Special threephase infeed terminals are required for constructing Type E Starters with an insulated threephase busbar system (see page /8). The 3RV9 infeed system also enables the assembly of Type E Starters, see page /4 onwards. According to CSA, these terminal blocks and the phase barriers can be omitted when the device is used as a "Self-Protected Combination Motor Controller (Type E)". Link modules Feeders can be easily assembled from single devices with the help of the link modules. The following table shows the different combination options for devices with screw or spring-type terminals. Combination devices 3RV motor starter protectors/ circuit breakers 3RT contactors; 3RW30, 3RW40 soft starters; 3RF34 solid-state contactors -- Version not possible ) The link modules cannot be used for the 3RV.-4PA., 3RV.-4FA., 3RV.3-4K.., 3RV.3-4R.., 3RV.3-4K.., 3RV.3-4R.., 3RV7 and 3RV8 motor starter protectors/circuit breakers. ) To assemble the feeder between a motor starter protector and a soft starter in size S, the 3RA93-AC00 standard mounting rail adapter must be used. 3) The motor starter protector to contactor hybrid link modules cannot be used for the 3RV.-4PA., 3RV.-4FA., 3RV7 and 3RV8 motor starter protectors/circuit breakers. They are only suitable for constructing direct-on-line starters. Note: Link modules can be used in - Sizes S00 and S0: up to max. 3 A - Size S: up to max. A Hybrid link modules can be used in - Sizes S00 and S0: up to max. 3 A Link modules Screw terminals Spring-type terminals Size Size Link modules for connecting switching devices to 3RV motor starter protectors/circuit breakers ) 3RT contactors S00 S00 3RA9-3RA9- with AC or DA00 AA00 DC coil S0 S00 -- S S 3RA93- -- AA00 3RT contactors with AC coil 3RT contactors with DC coil 3RW30 soft starters 3RW30/ 3RW40 soft starters 3RF34 solidstate contactors S0 S0 3RA9- AA00 S00 S0 -- S0 S0 3RA9- BA00 S00 S0 -- S00 S00 3RA9- BA00 S0 S00 -- S0 S0 3RA9- BA00 S00 S0 -- S ) S ) 3RA93- AA00 -- S00/S0 S00 3RA9- -- BA00 3RA9- AA00 3RA9- AA00 3RA9- GA00 3RA9- GA00 Hybrid link modules for connecting contactors with spring-type terminals to 3RV motor starter protectors/circuit breakers with screw terminals 3) 3RT contactors S00 S00 3RA9- -- with AC or DC coil S0 S0 FA00 3RA9- FA00 -- Siemens Canada Limited Industrial Control Product Catalog 09 /9

Accessories Mounting accessories Selection and ordering data Version For motor starter protector size Innovations 3RV/3RT Order No. Terminal blocks and phase barriers for Self-Protected Combination Motor Controllers (Type E) according to UL 08 / UL 60947-4- Note: UL 08 / UL 60947-4- demands -inch clearance and -inch creepage distance at line side for Combination Motor Controller Type E. The following terminal blocks or phase barriers must be used on 3RV motor starter protectors. The terminal blocks or phase barriers cannot be used in combination with the 3RV9. three-phase busbars. For construction with three-phase busbars, see Accessories for busbar Terminal blocks type E 3RV9 8-H 3RV9 8-K For extended clearance and creepage distances ( and inch) Phase barriers For extended clearance and creepage distances ( and inch) Order Quantity S00, S0 3RV9 8-H unit S0 unit S 3RV9 3-E unit S3 3RT946-4GA07 unit S00, S0 3RV9 8-K unit S 3RV9 38-K unit 3RT946-4GA07 Actuating voltage of contactor Size 3RT contactor Link modules for motor starter protector to contactor ) 3RA9 -AA00 3RV motor starter protector Innovations 3RV/3RT Order No. Order Quantity For mechanical and electrical connection between motor starter protector and contactor with screw Screw Terminals terminals. Single-unit packaging AC/DC S00 S00/S0 3RA9 -DA00 unit AC S0 S00/S0 3RA9 -AA00 unit AC S S 3RA9 3-AA00 unit AC S3 S3 3RA9 4-AA00 unit DC S0 S00/S0 3RA9 -BA00 unit DC S S 3RA9 3-AA00 unit DC S3 S3 3RA9 4-AA00 unit Multi-unit packaging AC/DC S00 S00/S0 3RA9 -D 0 units AC S0 S00/S0 3RA9 -A 0 units DC S0 S00/S0 3RA9 -B 0 units AC/DC S S 3RA9 3-A units AC/DC S3 S3 3RA9 4-A units For mechanical and electrical connection between motor starter protector and contactor with spring-type terminals. Spring-type Terminals 3RA9 -AA00 Single-unit packaging AC/DC S00 S00 3RA9 -AA00 unit AC ) S0 S0 3RA9 -AA00 unit DC S0 S0 3RA9 -AA00 unit Multi-unit packaging AC/DC S00 S00 3RA9 -A 0 units AC ) S0 S0 3RA9 -A 0 units DC S0 S0 3RA9 -A 0 units Spacers For compensating height on AC contactors Single-unit packaging S0 S0 3RA9 -CA00 unit Multi-unit packaging S0 S0 3RA9 -C units ) The link modules for motor starter protector to contactor cannot be used for the 3RV. -4PA., 3RV. -4FA., 3RV7 and 3RV8 motor starter protectors ) A spacer for height compensation on AC contactors size S0 is optionally available Note Size S0 link modules can be used up to max. 3 A. Size S link modules can be used up to A max. /0 Siemens Canada Limited Industrial Control Product Catalog 09

Accessories Mounting accessories Selection and ordering data Size Order No. PU 3RW30, 3RW40 3RV (UNIT, soft starters; motor starter protectors SET, M) 3RF34 solid-state contactors PS* Weight approx. kg Link modules for motor starter protector to soft starter ) 3) and motor starter protector to solid-state contactor Connection between motor starter protector and soft Screw terminals starter / solid-state contactor with screw terminals Single-unit packaging S00 S00/S0 3RA9 -BA00 unit 0.068 S0 S00/S0 3RA9 -BA00 unit 0.068 S 3) S 3RA9 3-AA00 unit 0.04 S3 4) S3 3RA9 4-A unit 0.04 Multi-unit packaging S00 S00/S0 3RA9 -B 0 units 0.068 S0 S00/S0 3RA9 -B 0 units 0.068 3RA9 -BA00 S 3) S 3RA9 3-A units 0.04 S3 4) S 3RA9 4-A units 0.04 Connection between motor starter protector and soft starter with spring-type terminals Spring-type terminals 3RA9 -GA00 Single-unit packaging S00 S00 3RA9 -GA00 unit 0.038 S0 S0 3RA9 -GA00 unit 0.07 Multi-unit packaging S00 S00 3RA9 -G 0 units 0.380 S0 S0 3RA9 -G 0 units 0.70 ) The link modules for motor starter protector to soft starter and for motor starter protector to solid-state contactor cannot be used for the 3RV. -4PA., 3RV. -4FA., 3RV7 and 3RV8 motor starter protectors. Note: S0 link modules can be used up to max. 3 A. S link modules can be used up to max. A. Actuating voltage of contactor Size Order No. PU 3RT 3RV (UNIT, contactors motor SET, M) starter protectors PS* Weight approx. kg Hybrid link modules for motor starter protector to contactor ) For mechanical and electrical connection between motor starter protector with screw terminals and contactor with spring-type terminals Single-unit packaging AC/DC S00 S00 3RA9 -FA00 unit 0.09 /DC S0 S0 3RA9 -FA00 unit 0.06 AC ) 3RA9 -FA00 Multi-unit packaging AC/DC S00 S00 3RA9 -F 0 units 0.90 AC ) /DC S0 S0 3RA9 -F 0 units 0.60 Spacers ) for compensating the height on AC contactors Single-unit packaging S0 S0 3RA9 -CA00 unit 0.00 Multi-unit packaging S0 S0 3RA9 -C units 0.00 3RA9 -FA00 ) The hybrid link modules for motor starter protector to contactor cannot be Note: used for the 3RV. -4PA., 3RV. -4FA., 3RV7 and 3RV8 motor Hybrid link modules can be used up to max. 3 A. starter protectors or reversing starters. ) A spacer for height compensation on AC contactors size S0 is optionally available. See 3RA9-CA00 3) To assemble the starter between a motor starter protector and a soft starter in size S, the 3RA93-AC00 standard mounting rail adapter must be used. 4) It is only permissible to assemble the feeder between the motor starter protector and the soft starter in Size S3 on a mounting plate. Siemens Canada Limited Industrial Control Product Catalog 09 /

Accessories Mounting accessories Selection and ordering data Isolator module ) 3RV938-A without padlock 3RV9 8-A without padlock Type Design Visible isolating distance for isolating individual motor starter protectors from the network, lockable in isolating position. For MSP size Order No. Order Quantity Weight approx. (kg) S00, S0 3RV9 8-A unit 0.3 S ) 3RV9 38-A unit 0.368 Auxiliary terminal, 3 pole 3RT9 46-4F For connection of auxiliary and control cables to the main conductor connections S3 3RT9 46-4F unit 0.0 Covers 3RV (size S3) with 3RT9 46-4EA Terminal cover Additional touch guard for box terminals to be fitted at the box terminals ( units can be mounted per MSP) S 3RT9 36-4EA unit 0.04 S3 3RT9 46-4EA unit 0.09 3RV9 8-4AA00 Terminal cover For maintaining the required for cable lug and bar connection voltage clearance and as protection against the equipment being touched if distant box terminals are used ( units can be mounted per MSP) S3 3RT9 46-4EA unit 0.03 3RV9 08-4AA0 Terminal cover for devices with ring lug Main current level S00, S0 ) 3RV9 8-4AA00 unit 0.0 terminal connection For transverse auxiliary switches S00, S0 ) 3RV9 08-4AA0 unit 0.0 3RV9 08-0P Scale cover For covering the current setting scale. Packing unit: Bag with 0 scale covers. S00, S0, S 3) 3RV9 08-0P 0 units S3 3RV9 08-0P 0 units Fixing Material 3RB900-0B Push-in lugs Two units are required for For screwing the motor starter protector onto mounting plates. each motor starter protector. S00 3RB9 00-0B 0 units 0.0 Tools for opening spring-type terminals by hand 3RA9 08-A Screwdriver Length approx. 00 mm, For all devices with spring terminals 3.0 mm x 0. mm, titanium gray/black partially insulated S00, S0, S 3RA9 08-A unit 0.04 ) The isolator module for size S can be used only with 3RV motor starter protectors/circuit breakers up to max. A. Similarly, it cannot be used with the transverse auxiliary switch or three-phase busbars. ) Compatible with 3RV0 motor starter protectors. 3) Compatible with 3RV0, 3RV, and 3RV4 motor starter protectors. / Siemens Canada Limited Industrial Control Product Catalog 09

Accessories Rotary operating mechanisms Selection and ordering data Type Details Door-coupling rotary operating mechanisms for Classic and Innovations 3RV9 6-0B For MSP size Order No. The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and a 30/330 mm long extension shaft (6 mm x 6 mm). The door-coupling rotary operating mechanisms are designed to degree of protection IP64. The door locking device prevents accidental opening of the control cabinet door in the ON postion of the motor starter protector. The OFF position can be locked with up to 3 padlocks. Door-coupling rotary operating mechanisms (black) EMERGENCY STOP door-coupling rotary operating mechanisms (red/yellow) Approx. Wt. (kg) Extension shaft 30 mm S00, S0 3RV9 6-0B 0. S, S3 3RV9 6-0B 0. Extension shaft 330 mm S00, S0 3RV9 6-0K 0.34 S, S3 3RV9 6-0K 0.3 Extension shaft 30 mm S00, S0 3RV9 6-0C 0.0 S, S3 3RV9 6-0C 0. Extension shaft 330 mm S00, S0 3RV9 6-0L 0.36 S, S3 3RV9 6-0L 0.3 Door-coupling rotary operating mechanisms for arduous conditions 3RV9 6-C The door-coupling rotary operating mechanisms consist of a knob, a coupling driver, an extension shaft of 300 mm length (8 mm x 8 mm), a spacer and two metal brackets, into which the MSP is inserted. The door-coupling rotary operating mechanisms are designed for degree of protection IP. The door locking device reliably prevents accidental opening of the control cabinet door in the ON position of the MSP. The OFF postion can be locked with up to 3 padlocks. Laterally mountable auxiliary releases and two-pole auxiliary switches can be used. The door-coupling rotary operating mechanisms thus meet the requirements for isolating functions according to IEC 60 947-. Door-coupling rotary S00, S0 3RV9 6-B. operating mechanisms S 3RV9 36-B.6 (gray) S3 3RV9 46-B.7 EMERGNCY STOP door-coupling S00, S0 3RV9 6-C. rotary operating mechanisms S 3RV9 36-C. (red/yellow) S3 3RV9 46-C.7 Enclosures and front plates Front Plates 3RV9 3-4B + 3RV9 3-4G Type Details Molded-plastic front plate For actuation of 3RV MSPs in any with rotary operating mechanism, enclosure, degree of protection IP lockable. For actuation of 3RV motor (front plate) starter protectors in any enclosure Molded-plastic front plate with EMERGENCY STOP door-coupling rotary operating mechanisms (red/yellow) Holders for front plates Enclosures for wall mounting ) 3RV9 3-CA00 Molded-plastic enclosure for wall mounting with rotary operating mechanism, lockable, with metric cable gland 3RV9 3-DA0 Cast aluminum surface-mount enclosure with rotary operating mechanism, lockable, with metric cable gland Cast aluminum surface-mount enclosure with EMERGENCY-OFF rotary operating mechanism, red/yellow, lockable, with metric cable gland EMERGENCY-STOP operation of 3RV MSPs in any enclosure, degree of protection IP Holder is mounted on front plate, MSP size S00 or S0 with or without accessories is snapped in For MSP size S00, S0 S, S3 S00, S0 S, S3 Order No. Approx. Wt. (kg) 3RV9 3-4B 0.08 3RV9 3-4E 0.08 S00, S0 3RV9 3-4G 0.9 Degree of protection IP, with N and PE terminals, lockable in 0 position overall width: 4 mm (for switch + lateral auxiliary switch) S00, S0 3RV9 3-CA00 0.6 7 mm (for switch + lateral auxiliary switch + auxiliary release) Degree of protection IP, with PE terminals, ) lockable in 0 position overall width: 7 mm (for MSP + lateral auxiliary switch + auxiliary release) Degree of protection IP, with PE terminals, ) lockable in 0 position overall width: 7 mm (for MSP + lateral auxiliary switch + auxiliary release) S00, S0 3RV9 3-DA00 0.30 S00, S0 3RV9 3-DA0.0 S00, S0 3RV9 3-GA0.0 ) If required, an additional N terminal can be mounted (e.g. 8WA0 -BG). ) For S versions, see 3RV933-DA00 (black) or 3RV933-GA00 (red/yellow) Siemens Canada Limited Industrial Control Product Catalog 09 /3

Accessories 3RV9 infeed system Overview The 3RV9 infeed system is a convenient means of energy supply and distribution for a group of several motor starter protectors or complete motor starters with a screw or springtype connection in sizes S00 and S0 (exception: this system cannot be used for the 3RV, 3RV7 and 3RV8 motor starter protectors/circuit breakers). The 3RV9 infeed system is approved in accordance with IEC to 00V. It is also UL approved and authorized for Self- Protected Combination Motor Controller (Type E starter) as well as for Type F starter (Type E starter + contactor). The system is based on a basic module complete with a lateral incoming unit (three-phase busbar with infeed). This infeed with spring-type terminals is mounted on the right or left depending on the version and can be supplied with a maximum conductor cross-section of 4 AWG (with end sleeve). A basic module has two sockets onto each of which a motor starter protector can be snapped. Expansion modules are available for extending the system (three-phase busbars for system expansion). The individual modules are connected through an expansion plug. The electrical connection between the three-phase busbars and the motor starter protectors is implemented through plug-in connectors. The complete system can be mounted on a TH 3 standard mounting rail to EN 607 and can be expanded as required up to a maximum current carrying capacity of 63 A. The system is mounted extremely quickly and easily thanks to the simple plug-in technique. Thanks to the lateral infeed, the system also saves space in the control cabinet. The additional overall height required for the infeed unit is only 30 mm. The alternative infeed possibilities on each side offer a high degree of flexibility for configuring the control cabinet: Infeed on lefthand or right-hand side as well as infeed on one side and outfeed on the other side to supply further loads are all possible. A terminal block with spring-type connections in combination with a standard mounting rail enables the integration of not only motor starter protectors but also single-phase, -phase and 3-phase components such as SY miniature circuit breakers or relay components. 3b 3a 4 7 6 3a 3-phase busbar with infeed 3-phase busbar for system expansion Expansion plug 4 6 3b Extra-wide expansion plug 7 End cover Plug-in connector Contactor base Terminal block NSB0_0078 3RV9 infeed system /4 Siemens Canada Limited Industrial Control Product Catalog 09

Accessories 3RV9 infeed system $ Three-phase busbars with infeed A three-phase busbar with infeed unit is required for connecting the energy supply. This module comprises one infeed module and sockets which each accept one motor starter protector. A choice of two versions with infeed on the left or right is available. The infeed is connected using spring-type terminals. The spring-type terminals permit conductor cross-sections of up to mm with end sleeves. An end cover is supplied with each module. % Three-phase busbars for system expansion The three-phase busbars for system expansion allow the system to be expanded. There is a choice of modules with or 3 sockets. The system can be expanded as required up to a maximum current carrying capacity of 63 A. An expansion plug is supplied with each module. &a Expansion plug The expansion plug is used for electrical connection of adjacent three-phase busbars. The current carrying capacity of this plug equals 63 A. One expansion plug is supplied with each threephase busbar for system expansion. Additional expansion plugs are therefore only required as spare parts. &b Extra-wide expansion plug The wide expansion plug makes the electrical connection between two three-phase busbars, thus performing the same function as the 3RV9 7-BA00 expansion plug; the electrical characteristics (e.g. a current carrying capacity of 63 A) are identical. The 3RV9 7-E expansion plug is 0 mm wider than the 3RV9 7-BA00 expansion plug, hence in the plugged state there is a distance of 0 mm between the connected threephase busbars. This distance can be used to lay the auxiliary current and control current wiring ("wiring duct"). The motor starter protector and contactor can be wired from underneath, which means that the complete cable duct above the system can be omitted. ( End cover The end cover is used to cover the three-phase busbar at the open end of the system. This cover is therefore only required once for each system. An end cover is supplied with each threephase busbar system with infeed. Further end covers are therefore only required as spare parts. * Contactor base Motor starters can be assembled in the system using the contactor base. The contactor bases are suitable for contactors sizes S00 and S0 with spring-type and screw terminals and are simply snapped onto the three-phase busbars. Direct-on-line starters and reversing starters are possible. One contactor base is required for direct-on-line starters and two are required for reversing starters. To assemble motor starters for reversing starters, the contactor bases can be arranged alongside each other (90 mm overall width). In this case the mechanical interlocking of the contactors is possible. The contactor bases are also suitable for soft starters size S00 and S0 with screw connection. The infeed system is designed for mounting on a 3 mm standard mounting rail with 7. mm overall depth. This standard mounting rail gives the contactor base a stable mounting surface to sit on. If standard mounting rails with a depth of mm are used, the spacer connected to the bottom of the contactor base must be knocked out and plugged into the mating piece that is also on the underside. Then the contactor base also has a stable mounting surface. When standard mounting rails with a depth of 7. mm are used, the spacer has no function and can be removed. The link modules are used for direct start motor starters, in which case the use of a contactor base is not absolutely necessary. Motor starter protector and contactor assemblies can then be directly snapped onto the sockets of the three-phase busbars. For starters of size S00 and S0, the corresponding 3RA9 -..., 3RA9 -..., 3RA9 -... or 3RA9 -... link modules should generally be used. + Terminal block The 3RV9 7-D terminal block enables the integration of not only motor starter protectors but also single-phase, -phase and 3-phase components. Using the terminal block the 3 phases can be fed out of the system; which means that singlephase loads can also be integrated in the system. The terminal block is plugged into the slot of the expansion plug and thus enables outfeeding from the middle or end of the infeed system. The terminal block can be rotated through 80 and be locked to the support modules of the infeed system. The 3RV9 7-7B 4 mm standard mounting rail for screwing onto the support plate is available in addition in order to be able to plug the single-phase, -phase and 3-phase components onto the infeed system. ) Plug-in connector The plug-in connector is used for the electrical connection between the three-phase busbar and the 3RV motor starter protector. These plug-in connectors are available in versions for screw or spring-type terminals. Siemens Canada Limited Industrial Control Product Catalog 09 /

Accessories 3RV9 infeed system Selection and ordering data Three-phase busbars with infeed 3-phase busbars with infeed incl. end cover 3RV9 7-6A Type Version For 3RV0, 3RV3, 3RV4 motor starter protectors For motor starter protectors with screw connection or spring-type terminals With infeed on the left With infeed on the right Order No. Standard Pack Quantity Weight approx. S ize kg S00, S0 3RV9 7-A S00, S0 3RV9 7-E unit 0.369 unit 0.369 3RV9 7-A Three-phase busbars for system expansion Three-phase busbars incl. 3RV9 7- BA00 expansion plug For motor starter protectors with screw connection or spring-type terminals For motor starter protectors For 3 motor starter protectors S00, S0 3RV9 7-4A S00, S0 3RV9 7-4B unit 0.9 unit 0.38 3RV9 7-4A Plug-in connectors Plug-in connectors to make contact with the motor starter protectors For spring-type terminals - Single-unit packaging - Multi-unit packaging Spring-type terminals S00 ) 3RV9 7-AA00 S0 ) 3RV9 7-AA00 S00 ) 3RV9 7-A S0 ) 3RV9 7-A unit 0.046 unit 0.09 0 units 0.046 0 units 0.09 3RV9 7-AA00 3RV9 7-CA00 For screw terminals - Single-unit packaging - Multi-unit packaging Screw terminals S00 ) 3RV9 7-CA00 S0 ) 3RV9 7-AA00 S00 ) 3RV9 7-C S0 ) 3RV9 7-A unit 0.09 unit 0.040 0 units 0.09 0 units 0.036 Contactor bases Type Version For contactors Contactor bases for mounting direct-on-line or reversing starters Single-unit packaging Order No. Standard Pack Quantity Weight approx. S ize kg S00 3RV9 7-7AA00 S00, S0 3RV9 7-7AA00 unit 0.04 unit 0.00 3RV9 7-7AA00 ) > 4 A, note derating; see the system manual " Innovations", Chapter "Motor Starter Protectors". ) > 6 A, note derating; see the system manual " Innovations", Chapter "Motor Starter Protectors". /6 Siemens Canada Limited Industrial Control Product Catalog 09

Accessories 3RV9 infeed system Terminal blocks Type Version Order No. Standard Pack Quantity Weight approx. kg Terminal blocks For integration of single-phase, two-phase and three-phase components Single-unit packaging 3RV9 7-D unit 0.049 3RV9 7-D 4 mm standard mounting rails 4 mm standard mounting rails for mounting onto bus bar adapters Single-unit packaging 3RV9 7-7B unit 0.6 3RV9 7-7B Extra-wide expansion plugs Extra-wide expansion plugs as accessory Single-unit packaging 3RV9 7-E unit 0.037 3RV9 7-E Expansion plugs Expansion plugs ) as spare part Single-unit packaging 3RV9 7-BA00 unit 0.06 3RV9 7-BA00 End covers End covers ) as spare part Multi-unit packaging 3RV9 7-6A 0 units 0.00 3RV9 7-6A ) The expansion plug is included in the scope of supply of the 3RV9 7-4 three-phase busbars for system expansion. ) The end cover is included in the scope of supply of the 3RV9 7- threephase busbars with infeed system. Siemens Canada Limited Industrial Control Product Catalog 09 /7

3RV up to 00 A (Domestic applications) Permissible rated data of devices approved for North America (UL/CSA) Motor starter protectors of the 3RV series are approved for UL/CSA, and according to UL08/UL 60947-4- and CSA C. No. 4/CSA C. No. 60947-4- they can be used on their own or as load feeders in combination with a contactor. 3RV motor starter protectors as "Manual Motor Controllers" If used as a "Manual Motor Controller", the motor starter protector is always operated in combination with an upstream short-circuit protection device. Approved fuses or a circuit breaker according to UL 489/CSA C. No. can be used. These devices must be dimensioned according to the National Electrical Code (UL) or Canadian Electrical Code (CSA). These motor starter protectors can be used as "Manual Motor Controllers" for "Group Installations", as "Manual Motor Controllers Suitable for Tap Conductor Protection in Group Installations" and as "Self-Protected Combination Motor Controllers" (Type E). Approval of the 3RV as a Manual Motor Controller can be found under the following file numbers: ULFile No. 4770, CCN: NLRV, CSA Master Contract 07, Product Class: 3 0. Motor starter protectors hp rating ) for FLA ) max. Rated current I n 40 V AC UL/CSA I 3) bc 480 V AC UL/CSA I 3) bc 600 V AC UL/CSA I 3) bc Type V -phase 3-phase A Size S00 3RV0, 3RV, 3RV3, 3RV4 0.6.... 3. FLA ) max. 6 A,480 V 00 3. A, 600 V 30 460 -- 0 7/600 -- 0 ka ka 4 6.3 8 0. 6 Size S0 3RV0, 3RV, 3RV3, 3RV4 0.6.... 30 6... --/(30) 4) FLA ) max. 3 8, 3 0 -- 40 A, 480 V 00 0 36, 40 -- 30 7 / 0 460 -- 30 7/600 -- -- Size S 3RV03 3RV03 3RV03 3RV03 3RV03 3RV03 4 00 00 3RV03, 3RV3, 3RV33, 3RV03, 3RV33 7 00 00 0 00 00 FLA ) MAX. A /0 0 00 00 600V 00/08 0 0 3 00 00 NEMA size 30/40 36 00 00 460/480 0 40 00 00 7/600 60 4 00 00 00 00 a) with max A Class J fuse 9 a) 00 a) a) 00 a) 0 a) a) b) with max 0A Class J fuse b) 00 b) b) 00 b) 0 b) b) Size S3 3RV0 4/3RV0 4, 3RV 4, 3RV3 4/3RV3 4 6 30 0 30 FLA ) max. 99 A, 7 / -- 30 600 V 00 0 30 3 30 NEMA size 3 30 0 40 40 30 460 -- 7 0 30 7/600 -- 00 63 30 7 30 90 0 00 0 ) HP rating = Power rating in horse power (maximum motor rating). ) FLA = Full Load Amps/Motor full load current. 3) Corresponds to "short-circuit breaking capacity" according to UL/CSA. 4) The values in brackets only apply to 3RV.3 motor starter protectors. ka 30 30 30 30 30 30 30 30 30 /8 Siemens Canada Limited Industrial Control Product Catalog 09

3RV up to 00 A (Domestic applications) 3RV motor starter protectors as "Manual Motor Controllers Suitable for Tap Conductor Protection in Group Installations" The application as "Manual Motor Controllers Suitable for Tap Conductor Protection in Group Installations" is only available from UL. CSA does not recognize this approval! When the motor starter protector is used as a "Manual Motor Controller Suitable for Tap Conductor Protection in Group Installations", it must always be combined with upstream short-circuit protection. As short-circuit-protection device, approved fuses or a motor starter protector according to UL 489 can be used. These devices must be dimensioned according to the National Electrical Code. The 3RV motor starter protectors are approved as "Manual Motor Controllers Suitable for Tap Conductor Protection in Group Installations" under the following file number: ULFile No. 4770, CCN: NLRV. Motor starter protectors hp rating ) for FLA ) max. Rated 40 V AC Up to 480Y/77V AC Up to 600Y/347V AC current I n UL UL UL 3) 3) 3) I bc I bc I bc Type V -phase 3-phase A ka ka ka Size S00 3RV0 0.6... 0.8 30 30 FLA ) max.6 A, /0. 30 480 Y / 77 V 00/08 3 30 NEMA size 0 30/40. 30 460/480 -- 0 3. 30 7/600 -- 0 4 30 30 6.3 30 8 30 6 Size S0 3RV0 0.63....6 30 30 FLA ) max. /0. 30 A, 480 Y / 77 V 00/08 3 7. 3. 30. A, 600 V 30/40 3 0 4 30 460/480 3 0 30 NEMA size 7/600 6.3 30 8 30 0 30. 30 3 0 0 Size S 3RV03 3RV03 3RV03 3RV03 3RV03 3RV03 4 00 00 3RV03, 3RV03, 3RV43 7 00 00 0 00 00 FLA ) MAX. A /0 0 00 00 600V 00/08 0 0 3 00 00 NEMA size 30/40 36 00 00 460/480 0 40 00 00 7/600 60 4 00 00 00 00 9 00 30 4 -- -- 00 30 4 -- -- Size S3 3RV0 4. 6 30 0 30 FLA ) max. /0 7 / -- 30 00 A, 480 V 00/08 0 30 3 30 7 A, 600 V 30/40 0 40 40 30 460/480 -- 7 0 30 NEMA size 3 7/600 -- 7 63 30 7 30 90 -- 00 -- ) HP rating = Power rating in horse power (maximum motor rating). ) FLA = Full Load Amps/Motor full load current. 3) Complies with "short-circuit breaking capacity" according to UL. Siemens Canada Limited Industrial Control Product Catalog 09 /9

3RV up to 00 A (Domestic applications) 3RV motor starter protectors as "Self-Protected Combination Motor Controllers (Type E)" UL 08/UL 60947-4- approval demands -inch clearance and -inch creepage distance at line side for Self-Protected Combination Motor Controller Type E. Therefore, 3RV0 motor starter protectors of sizes S00 to S are approved according to UL 08/UL 60947-4- in combination with the terminal blocks listed below. CSA does not require these extended clearances and creepage distances. According to CSA, these terminal blocks can be omitted when the device is used as a Self-Protected Combination Motor Controller. The 3RV0 motor starter protectors are approved as Self-Protected Combination Motor Controllers under the following file numbers: UL File No. E6943, CCN: NKJH CSA Master Contract 07, Product Class: 3 08 Motor starter hp rating ) for FLA ) Rated current Up to 40 V AC Up to 480 Y/77 V AC Up to 600 Y/347 V AC protectors max. I n UL/CSA I 3) bc UL/CSA I 3) bc UL/CSA I 3) bc Type V -phase 3-phase A ka ka ka Size S00 3RV0 + 3RV9 8-H4) ) FLA ) max. 6 A 480 V 00 3 NEMA size 0 30 30 7/600 0 0 Size S0 0.6.... 6 3RV0 + 3RV9 8-H 4) ) 0.63....6 30 30 FLA ) max.. 30 A, 480 V 00 3 7. 3. 30. A, 600 V 30 3 0 4 30 460 0 30 NEMA size 7/600 6.3 30 8 30 0 30. 30 6 0 3 0 0 Size S 3RV03 3RV03 3RV03 3RV03 3RV03 3RV03 4 00 00 3RV03/3RV03 + 3RV938-K 4) 7 00 00 0 00 00 FLA ) MAX. A /0 0 00 00 600V 00/08 0 0 3 00 00 NEMA size 30/40 36 00 00 460/480 0 40 00 00 7/600 60 4 00 00 00 00 9 00 0 30 00 0 30 Size S3 3RV04 + 3RT946-4GA07 4) 6 30 0 30 FLA ) max. 0 -- 30 00 A, 480 V 00 0 30 3 30 7 A, 600 V 30 0 40 40 30 460 -- 7 0 30 NEMA size 3 7/600 -- 7 63 30 7 30 90 00 Ratings of the auxiliary switches and alarm switches ) HP rating = Power rating in horse power (maximum motor rating). ) FLA = Full Load Amps/Motor full load current. Lateral auxiliary switch with NO + NC, NO, NC, NO + NC and signalling switch Transverse auxiliary switch with changeover contact Max. rated voltage to NEMA u AC V 600 0 to NEMA s AC V 600 0 Uninterrupted current A 0. Breaking capacity A600 B600 C300 Q300 R300 R300 3) Corresponds to "short-circuit breaking capacity" according to UL/CSA. 4) Not required for CSA. ) Alternatively, the 3RV98-K phase barrier can also be used. 30 Transverse auxiliary switch with NO + NC, NO /0 Siemens Canada Limited Industrial Control Product Catalog 09

3RV7/8 circuit breakers 3RV7/8 circuit breakers These circuit breakers are approved according to UL 489 and CSA C. No. -0 for 00 % rated current (00 % rated breaker). They can be used therefore as upstream short-circuit protective devices for "Manual Motor Controllers" and "Manual Motor Controllers Suitable for Tap Conductor Protection in Group Installations". The 3RV7/8 circuit breakers are approved under the following file numbers: ULFile No. E3044, CCN: DIVQ, CSA Master Contract 07, Product Class: 43 0. 40 V AC 480 Y/77 V AC 480 V AC 600 Y/347 V AC Circuit breakers Rated current I n UL/CSA UL/CSA UL/CSA UL/CSA Type A ) I bc ka ) I bc ka ) I bc ka ) I bc ka Size S00/S0 3RV7 / 3RV8 0.6. 0 3RV7 / 3RV8.6 0 0. 0 3. 0 4 0 0 6.3 0 8 0 0 0. 0 -- 0 0 0 0 -- 0 0 0 -- Size S3 3RV7 4 0 0 0 0 0 0 30 0 3 -- 0 40 -- 0 4 -- 0 0 -- 0 60 -- 0 70 -- 0 ) Complies with "short-circuit breaking capacity" according to UL. Siemens Canada Limited Industrial Control Product Catalog 09 /

3RV up to 00 A (Export applications) Technical specifications Short-circuit breaking capacity I cu, I cs acc. to IEC 60947- This table shows the rated ultimate short-circuit breaking capacity I cu and the rated service short-circuit breaking capacity I cs of the 3RV motor starter protectors/circuit breakers with different inception voltages dependent of the rated current I n of the motor starter protectors/circuit breakers. Power can be supplied to the motor starter protectors/circuit breakers via the terminals at the top or at the bottom without restricting the rated data. If the short-circuit current at the place of installation exceeds the rated short-circuit breaking capacity of the motor starter protector/circuit breaker as specified in the table, a back-up fuse is required. It is also possible to install an upstream motor starter protector/circuit breaker with a limiter function. The maximum rated current for the back-up fuse is specified in the tables. The rated ultimate short-circuit breaking capacity then applies as specified on the fuse. Fuseless construction Motor starter protector contactor combinations for short-circuit currents up to 0 ka can be ordered in the form of fuseless load feeders according to Chapter 6. Motor starter protectors/circuit breakers Rated current Up to 40 V AC ) Up to Up to Up to Up to 690 V AC ) I n 400 V ) /4 V AC ) 440 V ) /460 V AC ) 00 V ) / V AC ) I cu I cs Max. fuse (gl/gg) (these values do not apply to 3RV7 4 circuit breakers) I cu I cs Max. fuse (gl/gg) 3) I cu I cs Max. fuse I cu (gl/gg) 3) I cs Max. fuse I cu (gl/gg) 3) I cs Max. fuse (gl/gg) 3)4) Type A ka ka A ka ka A ka ka A ka ka A ka ka A Size S00 3RV. 0.6... 00 00 00 00 00 00 00 00 00 00.;.6 00 00 00 00 00 00 00 00 00 00 ;. 00 00 00 00 00 00 00 00 0 0 3.; 4 00 00 00 00 0 0 00 00 0; 6 0; 4 3 ; 6.3 00 00 00 00 0 0 00 00 6 4 3 8 00 00 0. 0 0 63 4 4 63 6 4 0 0 00 00 0. 0 0 80 4 4 63 6 4 0 6 00 00 00 00 0. 30 00 0 0 0 0 80 80 4 0 4 80 80 4 4 4 4 63 63 Size S0 3RV. 6 00 00 00 0 0 80 0 80 4 63 0 00 00 0 0 80 0 80 4 63 00 00 0 0 00 0 80 4 63 00 00 0 0 00 0 80 4 63 8 00 00 30 0 0 00 4 00 3 00 00 30 0 0 00 4 00 36 00 00 0 0 8 6 3 00 3 00 40 00 00 0 0 8 6 3 00 3 00 Size S 3RV.3 4; 7 00 00 30 00 0 00 6 63 3 63 0 00 00 30 00 0 00 6 80 3 80 00 00 30 00 0 00 6 80 3 80 3; 36 00 00 30 0 0 00 4 00 40; 4 00 00 30 60 0 0 00 4 00 00 00 30 60 0 0 4 9... 80 Values on request Size S, with increased switching capacity 3RV.3 4; 7 00 00 00 0 30 00 8 0 63 8 63 0; 00 00 00 0 30 00 8 0 80 8 80 3... 4 00 00 00 0 30 8 00 6 4 00 00 00 00 0 30 8 6 4 9... 80 Values on request Size S3 3RV. 4 40 00 00 0 0 0 6 00 6 3 63 0 00 00 0 0 0 6 00 6 3 80 63 00 00 0 60 0 0 60 6 00 6 3 80 7 00 00 0 60 0 0 60 8 4 3 00 90; 00 00 00 0 60 0 0 60 8 4 3 Short-circuit resistant up to at least 0 ka No back-up fuse required, since short-circuit resistant up to 00 ka ) 0 % overvoltage. 4) ) Alternatively, fuseless limiter combinations for 690 VAC can also be used. % overvoltage. 3) Back-up fuse only required if the short-circuit current at the place of installation > I cu. / Siemens Canada Limited Industrial Control Product Catalog 09

3RV up to 00 A (Export applications) Short-circuit breaking capacity I cuit in the IT system (IT network) according to IEC 60947-3RV motor starter protectors are suitable for operation in IT systems. Values valid for triple-pole short-circuit are I cu up to I cs. In case of double ground fault on different phases at the input and output side of a motor starter protector, the special short-circuit breaking capacity I cuit applies. The specifications in the table below apply to 3RV motor starter protectors. In the colored areas, I cuit is 00 ka, or in some ranges it is 0 ka. Therefore the motor starter protectors are short-circuit resistant in these ranges. If the short-circuit current at the place of installation exceeds the rated short-circuit breaking capacity of the motor starter protector as specified in the table, a back-up fuse is required. The maximum rated current for the back-up fuse is specified in the tables. The rated short-circuit breaking capacity then applies as specified on the fuse. Motor starter protectors Rated current Up to 40 V AC ) Up to 400 V ) /4 V AC ) Up to 00 V ) / V AC ) ) ) Up to 690 V AC I n I cuit Max. fuse I cuit Max. fuse I cuit Max. fuse I cuit Max. fuse (gl/gg) 3) (gl/gg) 3)4) (gl/gg) 3) (gl/gg) 3) Type A ka A ka A ka A ka A Size S00 3RV0, 0.6... 0.63 00 00 On request On request On request On request 3RV6-0BD0 0.8; 00 00.;.6 00 00 ;. 00 8 3.; 4 00 8;4 3 ; 6.3 00 4 3:0 8; 0 00 4 0. 00 4 63 6 80 4 63 Size S0 3RV. 6 80 4 63 0. 40 0 80 4 63 0. 0 80 4 63 0. 0 80 4 63 0. 0 8 80 63 63. 63 3 80 63 63. 63 36 0 80 63 63. 63 40 0 80 63 63. 63 Size S 3RV.3 4... 00 8 00 6 80 4 63 3...4 00 6 4 00 3 80 00 4 60 3 00 9... 80 Values on request Size S, with increased switching capacity 3RV.3 4... 00 8 00 6 80 4 63 3... 4 00 6 6 00 4 80 00 6 60 6 4 00 9... 80 Values on request Size S3 3RV. 4 40 0 0 63 0 0 0 0 8 80 3 63 3 63 63 0 60 6 80 3 63 3 63 7 0 60 00 80 80 90; 00 0 60 00 00 Short-circuit resistant up to at least 0 ka No back-up fuse required, since short-circuit resistant up to 00 ka ) 0 % overvoltage. ) % overvoltage. 3) Back-up fuse only required, if short-circuit current at the place of installation > I cuit. 4) Alternatively, fuseless limiter combinations for 690 VAC can also be used. ) Over-voltage category II applies for applications on IT systems > 600V Siemens Canada Limited Industrial Control Product Catalog 09 /3

3RV up to 00 A Technical data Rules for mounting motor starter protectors/circuit breakers When mounting MSPs, the following clearance must be maintained to grounded or live parts. MSP Clearance to grounded or live parts Y X at the side Z mm mm mm Type size 3RV. S00 up to 690 V 30 70 9 3RV. S0 ) up to 00 V 30 90 9 up to 690 V ) 0 90 30 3RV. 3 S up to 690 V 0 0 3RV. 4 S3 up to 40 V 0 67 0 up to 440 V 70 67 0 up to 00 V 0 67 0 up to 690 V 0 67 30 3RV7 4 S3 up to 40 V 90 67 0 up to 400 V 90 67 0 Minimum clearance between MSPs and grounded or live parts ) Up to and including the setting range of 3 A. For the 36/40 A setting range the clearance is 70 mm. ) In conjunction with the type E terminal block 3RV98-H the applicable lateral clearance is 30 mm for all voltages. Standard mounting for S0, S and S3 Wiring module Size S0: 3RV9 -AB Size S: 3RV9 3-A Size S3: 3RA9 43-3D (Caution: The wiring module demands 0 mm spacing between the MSPs) Line side Load side /4 Siemens Canada Limited Industrial Control Product Catalog 09

3RV up to 80 A General data Type 3RV.. 3RV.. 3RV.3. 3RV7, 3RV8 Size S00 S0 S S00, S0 Dimensions (W x H x D) Screw terminals Spring-type terminals Standards IEC 60947-, EN 60947- (VDE 0660 Part 00) mm mm 4 x 97 x 9 4 x 06 x 9 4 x 97 x 9 4 x 9 x 9 x 40 x 49 -- Yes IEC 60947-, EN 60947- (VDE 0660 Part 0) Yes IEC 60947-4-, EN 60947-4- (VDE 0660 Part 0) Yes Yes Yes -- UL 08/UL 60947-4-, CSA C. No. 4/CSA C. No. 60947-4- Yes Yes Yes -- UL 489, CSA C. No. -- -- -- Yes Number of poles 3 Max. rated current I n max A 6 40 80 (= max. rated operational current I e ) Permissible ambient temperature Storage/transport C 0... +80 Operation I n : 0.6... 3 A C 0... +70 (current reduction above +60 C) -- I n : 36... 40 A C -- 0... +40 (the devices must not be mounted side-by-side and they must not be assembled with link modules with contactors. A lateral clearance of 9 mm is required.) -- I n : 4... 80 A C -- 0... +70 -- (current reduction above +60 C) Permissible rated current at inside temperature of control cabinet +60 C % 00 +70 C % 87 Permissible rated current at ambient temperature of enclosure (applies for motor starter protector/circuit breaker inside enclosure 3 A) +3 C % 00 On 00 +60 C % 87 request 87 Rated operational voltage U e Acc. to IEC V AC 690 (when a molded-plastic enclosure is used only 00 V) Acc. to UL/CSA V AC 600 Rated frequency Hz 0/60 Rated insulation voltage U i V 690 Rated impulse withstand voltage U imp kv 6 Utilization category IEC 60947- (motor starter protector/circuit breaker) A IEC 60947-4- (motor starter) AC-3 Trip class CLASS Acc. to IEC 60947-4- 0 0/0 -- DC short-circuit breaking capacity (time constant t = ms) conducting path 0 V DC ka 0 On 0 conducting paths in series 300 V DC ka 0 request 0 3 conducting paths in series 40 V DC ka 0 0 Power loss P v for each motor starter protector/circuit breaker Dependent on the rated current I n (upper setting range) P R per conducting path = -------------- Ι 3 H W D I n : 0.6... 0.63 A W -- I n : 0.8... 6.3 A W 6 -- 6 I n : 8... 6 A W 7 -- 7 I n : 6 A W -- 7 0 7 I n : 7... A W -- 8 8 I n : 8... 3 A W -- 4 -- I n : 36... 40 A W -- 4 -- I n : 4... A W -- -- 7 -- I n :... 80 A W -- -- On request -- Shock resistance Acc. to IEC 60068--7 g/ms / (square and sine pulse) Degree of protection Acc. to IEC 609 IP0 Touch protection Acc. to EN 074 Finger-safe for vertical contact from the front Temperature compensation Acc. to IEC 60947-4- C 0... +60 Phase failure sensitivity Acc. to IEC 60947-4- Yes (only for 3RV3 motor starter protectors) No Explosion protection Safe operation of motors with Yes (only for 3RV0 motor starter protectors) "increased safety" type of protection EC type test certificate number according to directive 94/9/EC (ATEX) DMT 0 ATEX F 00 II () GD On request No 4 x 44 x 9 -- Siemens Canada Limited Industrial Control Product Catalog 09 /

3RV up to 80 A Conductor cross-sections of main circuit Type 3RV. 3RV. 3RV.3-4B., 3RV.3-4D.., 3RV.3-4E.., 3RV.3-4P.., 3RV.3-4S.., 3RV.3-4T.., 3RV.3-4U.., 3RV.3-4V.. 3RV.3-4J.., 3RV7, 3RV8 3RV.3-4K.., 3RV.3-4R.., 3RV.3-4W.., 3RV.3-4X.., 3RV43-4VA., 3RV.3 Size S00 S0 S S00, S0 Connection type Screw terminals Terminal screw M3, Pozidriv size ) If two different conductor cross-sections are connected to one clamping point, both cross-sections must be in the range specified. M4, Pozidriv size M6, Pozidriv size M4, Pozidriv size Operating devices mm... 6... 6... 6... 6 Prescribed tightening torque Nm 0.8........ 3.0... 4..... 3 Conductor cross-sections (min./max.), or conductors can be connected Solid or stranded mm x (0.7....) ), x 4 Finely stranded with end sleeve (DIN 468-) mm x (0.....) ), x (....) ), x (0.7....) ) x (.... 6) ), x 0 AWG cables, solid or stranded AWG x (0... 6) ), x (8... ) ) Connection type Spring-type terminals Operating devices mm 3.0 x 0. and 3. x 0. Conductor cross-sections (min./max.), or conductors can be connected Solid or stranded mm x (0.... 4) x (... 0) -- Finely stranded without end sleeve mm x (0.....) x (... 6) -- Finely stranded with end sleeve (DIN 468-) mm x (0.....) x (... 6) -- AWG cables, solid or stranded AWG x (0... ) x (8... 8) -- Max. external diameter of the conductor insulation mm 3.6 3.6 -- Connection type Ring terminal lug connections Terminal screw M3, Pozidriv size x (....) ), x (... ) ), x (... 3) ), x (... 0) ), x (.... 0) ) x (... 3) ) x (... 0) ) max. x x (... 6) ), x (... ) ), x (... 6), x (... ) ) x (... 3) ) max. 6 + 6 x (6... ) ), x (8... 3) ), x (8... ) ), x (4... 0) x (4... 8) ) x (8... ) ) x (8... ) ) M4, Pozidriv size Operating devices mm... 6... 6 -- Prescribed tightening torque Nm 0.8........ -- Usable ring terminal lugs d 3 mm d = min. 3., d = min. 4.3, -- DIN 4634 without insulation sleeve DIN 46 without insulation sleeve DIN 4637 with insulation sleeve JIS C80 Type R without insulation sleeve JIS C80 Type RAV with insulation sleeve JIS C80 Type RAP with insulation sleeve d d 3 = max. 7. d 3 = max.. I0_740 -- /6 Siemens Canada Limited Industrial Control Product Catalog 09

3RV up to 80 A Front transverse auxiliary switches 3RV.. 3RV.. 3RV.3. 3RV7, 3RV8 S00 S0 S S00, S0 Switching capacity for different voltages CO NO + NC, NO Rated operational current e At AC-, alternating voltage - 4 V A 4-30 V A 3 0. At AC- = th, alternating voltage - 4 V A 0. - 30 V A 0. At DC-3, direct voltage L/R 00 ms - 4 V A - 48 V A -- 0.3-60 V A -- 0. - 0 V A 0. -- - 0 V A 0. -- Minimum load capacity V 7 ma Front transverse solid-state compatible auxiliary switches Rated operational voltage U e Alternating voltage V Rated operational current e /AC-4 at U e = V A 0. Rated operational voltage U e Direct voltage L/R 00 ms V 60 Rated operational current e /DC-3 at U e = 60 V A 0.3 Minimum load capacity V ma Lateral auxiliary switches with signaling switch Switching capacity for different voltages CO Switching capacity for different voltages: Lateral auxiliary switch with NO + NC, NO, NC, NO + NC Signaling switch Rated operational current e At AC-, alternating voltage - 4 V A 6-30 V A 4-400 V A 3-690 V A At AC- = th, alternating voltage - 4 V A 0-30 V A 0-400 V A 0-690 V A 0 At DC-3, direct voltage L/R 00 ms - 4 V A - 0 V A 0. - 0 V A 0. - 440 V A 0. Minimum load capacity V 7 ma Auxiliary releases Power consumption Undervoltage releases Shunt releases During pick-up - AC voltages VA/W 0./3 0./3 - DC voltages W 0 3... 80 During uninterrupted duty - AC voltages VA/W 7./.4 -- - DC voltages W. -- Response voltage Tripping V 0.3... 0.7 x U s 0.7.... x U s Pick-up V 0.8.... x U s -- Opening time maximum Short-circuit protection for auxiliary and control circuits ms 0 Melting fuses operational class gg A 0 Miniature circuit breakers C characteristic A 6 (prospective short-circuit current < 0.4 ka) Siemens Canada Limited Industrial Control Product Catalog 09 /7

3RV up to 80 A Conductor cross-sections for auxiliary and control circuits Type 3RV. 3RV. 3RV.3, 3RV.3 3RV7, 3RV8 Size S00 S0 S S00, S0 Connection type Screw terminals Terminal screw M3, Pozidriv size Operating devices mm... 6 Prescribed tightening torque Nm 0.8.... Conductor cross-sections (min./max.), or conductors can be connected Solid or stranded mm x (0.....) ), x (0.7....) ) Finely stranded with end sleeve (DIN 468-) mm x (0.....) ), x (0.7....) ) AWG cables, solid or stranded AWG x (8... 4) ), x (0... 6) ) Connection type Spring-type terminals Operating devices mm 3.0 x 0. and 3. x 0. Conductor cross-sections (min./max.), or conductors can be connected Solid or stranded mm x (0.....) Finely stranded without end sleeve mm x (0.....) Finely stranded with end sleeve (DIN 468-) mm x (0.....) AWG cables, solid or stranded AWG x (0... 4) Max. external diameter of the conductor insulation mm 3.6 Connection type Terminal screw M3, Pozidriv size Operating devices mm... 6 Tightening torque Nm 0.8.... ) If two different conductor cross-sections are connected to one clamping point, both cross-sections must be in the range specified. ) The following can be connected when both clamping points are connected: - Front... 0 mm² and rear... 0 mm² - Front... 6 mm² and rear... 6 mm² Ring terminal lug connections Usable ring terminal lugs d 3 mm d = min. 3., d 3 = max. 7. DIN 4634 without insulation sleeve d DIN 46 without insulation sleeve DIN 4637 with insulation sleeve JIS C80 Type R without insulation sleeve JIS C80 Type RAV with insulation sleeve JIS C80 Type RAP with insulation sleeve Terminals for "Self-Protected Combination Motor Controllers (Type E) according to UL 08/UL 60947-4-" Type 3RV98-H Prescribed tightening torque Nm.... 3 Conductor cross-sections Front clamping point connected - Solid mm²... 0 - Finely stranded with end sleeve mm²... 6 - Stranded mm².... - AWG cables, solid or stranded AWG 4... 3 - Terminal screw M4 Rear clamping point connected - Solid mm²... 0 - Finely stranded with end sleeve mm²... 6 - Stranded mm².... - AWG cables, solid or stranded AWG 4... 6 - Terminal screw M4 Both clamping points connected NSB0_00479 NSB0_00480 NSB0_0048 - Front clamping point: Solid Finely stranded with end sleeve Stranded AWG cables, solid or stranded Terminal screw - Rear clamping point: Solid Finely stranded with end sleeve Stranded AWG cables, solid or stranded Terminal screw I0_740 mm²... 0 mm²... 0 ),... 6 ) mm².... 0 AWG 4... 6 M4 mm²... 0 mm²... 0 ),... 6 ) mm².... 0 AWG 6... 3 M4 /8 Siemens Canada Limited Industrial Control Product Catalog 09

3RV up to 00 A Overview S00 MSP with laterally mounted undervoltage release with leading auxiliary switch 3RV Motor Starter Protectors (MSPs) are built for a world of applications while meeting the requirements of control users worldwide. Each MSP features a manual ON/OFF switch, a Class 0 adjustable bimetallic overload relay (Class 0 available in the two largest frame sizes), and magnetic trip elements for short circuit protection. Construction The motor starter protectors are available in four sizes: Size S00-3RV0 Maximum rated current is 6 Amps. Suitable for motors up to 0 HP at 600V. Available in both screw terminal and springtype terminal versions. Size S0-3RV0 Maximum rated current is 40 Amps. Suitable for motors up to 0 HP at 600V. Available in both screw terminal and springtype terminal verisons. Size S - 3RV03 Maximum rated current is 0 Amps. Suitable for motors up to 0 HP at 600V. Size S3-3RV04 Maximum rated current is 00 Amps. Suitable for motors up to 00 HP at 600V. Functions Releases 3RV motor starter protectors are equipped with bimetallicbased, inverse-time delayed overload releases - electromagnetic short-circuit releases. The overload releases can be set in accordance with the load current. The overcurrent releases are permanently set to a value 3 times the rated current and thus enable trouble-free start-up of motors. The scale cover can be sealed to prevent unauthorized adjustments to the set current. Release classes The release classes of thermally delayed releases are based on the tripping time (t A ) at 7. times the operational current in cold state (excerpt from IEC 60 947-4): CLASS 0 A s < t A < 0 s CLASS 0 4 s < t A < 0 s CLASS 0 6 s < t A < 0 s CLASS 30 9 s < t A < 30 s The release must trip within this time! Operating mechanisms S00, S0, S and S3 MSPs are actuated via a rotary operating mechanism. If the MSP trips, the rotary operating mechanism switches to the tripped position to indicate this. Before the MSP is reclosed, the rotary operating mechanism must be reset manually to 0 position, in order to prevent the former from closing by mistake before the fault has been cleared. In the case of MSPs with rotary operating mechanisms, an electrical signal can be output via a signalling switch to indicate that the MSP has tripped. All operating mechanisms can be locked in 0 position with a padlock (shackle diameter 3. to 4. mm). Application Operating conditions 3RV MSPs are suitable for use in any climate. They are designed for operation in closed rooms under normal conditions (e.g. no dust, corrosive vapours or harmful gases). Suitable enclosures must be provided for installation in dusty or damp rooms. Motor Protection 3RV MSPs use bimetallic heater elements to provide class 0 or 0 overcurrent protection for both AC and DC motors. The bimetallic heaters sense the motor current directly, so the overloads are insensitive to high frequencies, harmonic waves and sinusoidal currents and voltages. Each MSP has a fourth bimetallic strip that reacts only to the ambient temperature inside the control panel. This ambient compensation prevents the MSP from nuisance tripping when the panel temperature is higher than the ambient temperature of the motor. A built-in differential trip bar causes the MSP to trip faster on a phase loss condition, to help reduce motor damage from phase loss. Magnetic trip elements in each MSP take the device off line when it senses currents of 3 times the maximum FLA dial setting. 3RT 0-0 A A 0 MSP or Application Frame Size Standard Amperage Range Class Terminal Type Auxiliary Circuit Breaker 0 = Motor Protection 3 = S Possible choices listed below see A = 0 = Screw Switch 7 = UL 489 4 = S3 page /4-/7 for an entire listing = Spring Loaded 0,, 4 B through K 4 = Ring Lug 3RV 0-0 A A 0 Application Frame Size Standard Amperage Range Class Terminal Type Auxiliary Innovations 0 = Motor Protection = S00 Possible choices listed below see A = 0 = Screw Switch MSP or 7 = UL 489 = S0 page /4-/7 for an entire listing B = 0 = Spring Loaded Circuit Breaker 3 = S 0,, 4 B through K 4 = Ring Lug 4 = S3 Note: MPSs and Contactors of the same frame size are made to easily fit together with the use of a link module. Siemens Canada Limited Industrial Control Product Catalog 09 /9

Mounting accessories Applications: The 3RV MSPs can be used in a variety of applications: As a manual starter All 3RV MSPs are UL listed as Manual Motor Controllers per UL08. This makes them ideal for applications requiring simple manual starting and stopping of motors. A separate short circuit protective device, such as a circuit breaker or fuses, is still required ahead of the MSP. This up-stream protective device should be sized per NEC code, not to exceed 400% of the maximum FLA adjustment dial setting. As a component in a group installation A group motor installation indicates multiple motor controllers under one short circuit protective device, such as a circuit breaker. 3RV MSPs have a group installation short-circuit current rating of ka at 480V and up to 30kA at 600V. By using a link module, a 3RT contactor can be directly mounted to the load side of the MSP. 3RV MSPs have been UL tested with and without 3RT contactors for group installation. As a Self-protected manual combination starter, Type E. Most 3RV MSPs have also been UL listed as UL08 Type E, Selfprotected Manual Combination Starters. This UL listing allows the MSP to be mounted in a manually operated machine without having to add separate short circuit protection upstream. These devices have a short circuit current rating of ka @ 40V, 480Y/77V and up to 30kA @ 600Y/347V. As part of a Combination Motor Contoller, Type F When a 3RT contactor is connected to the load side of a 3RV device that is rated as a "Manual Self-protected Combination Motor Controller, Type E", the assembly can be applied as a "Combination Motor Controller, Type F". This versions allows for remote starting and stopping of the motor load. These assemblies have a short circuit current rating of ka @ 40V, 480Y/77V and up to 30 ka @ 600Y/347V. Terminals for "Combination Motor Controller Type E" to UL 08 The 3RV MSP for motor protection is approved according to UL 08 as "Combination Motor Controller Type E". As of July, 00, UL 08 demands at line-side of the device used for this purpose an increased clearance and creepage distance (" or "). Here, the terminal block 3RV9 8-H must be used for size S0. The block is simply screwed to the basic unit. Basic units of size S are already compliant with new clearance and creepage distance requirements. The terminal block 3RT9 46-4GA07 must be used for size S3. The standard box terminal is to be replaced by this terminal block. According to CSA, these terminal blocks can be omitted when the device is used as "Combination Motor Controller Type E". By using a link module, a 3RT contactor can be directly mounted to the load side of a 3RV MSP. This assembly of a 3RV and a 3RT provides a complete, remotely operated, combination starter, Type F. As a circuit breaker for export When exporting to many countries outside of the U.S. and North America, the 3RV can be applied as a thermal magnetic circuit breaker for use in motor branch circuits. 3RV9 8-K 3RV9 38-K 3RV9 8-H 3RT9 46-4GA07 Terminals for "Combination Motor Controller Type E" to UL 08 3RV9 8-H 44.8 73.6 3RT9 46-4GA07 38.9 7. /30 Siemens Canada Limited Industrial Control Product Catalog 09

3RV up to 00 A Switching of direct current 3RV motor starter protectors fo r alternating currents are also suitable for DC switching. The maximum permissible DC voltage per conducting path must, however, be adhered to. Higher voltages require a series connection with or 3 conducting paths. Example circuit for size S00 to S3 3RV motor starter protectors Example circuit for size S00 to S3 3RV motor starter protectors Maximum permitted DC voltage U e Notes The response values of the overload release remain unchanged; the response values of a short-circuit release increase by approximately 30 % for DC. The example circuits for DC switching can be seen in the table below. L+ L NSB0_0000a M L+ L M NSB0_0000a L+ L NSB0_00003a M 0 VDC Three-pole switching, non-grounded system ) If there is no possibility of a ground fault, or if every ground fault is rectified immediately (ground-fault monitoring), then the maximum permitted DC voltage can be tripled. 300 VDC Two-pole switching, grounded system The grounded pole is always assigned to the individual conducting path, so that there are always conducting paths in series in the event of a ground fault. 40 VDC Single-pole switching, grounded system 3 conducting paths in series. The grounded pole is assigned to the unconnected conducting path. ) It is assumed that this circuit always provides safe disconnection even in the event of a double ground fault that bridges two contacts. Design Mounting The motor starter protectors are secured in position by snapping them onto 3 mm standard mounting rails according to DIN EN 0 0. A mounting rail with a height of mm is required for S3 MSPs. A 7-mm mounting rail can be used as an alternative here. S and S3 MSPs can also be screwed directly onto a baseplate. The push-in lugs 3RV9 8-0B are available for screw mounting of S00 and S0 MSPs. 3RV98-0B Screw connection 3RV MSPs of sizes S00 and S0 are fitted with terminals with captive screws and clamping pieces, allowing the connection of conductors with different cross-sections. The box terminals of the S and S3 MSPs also enable conductors with different crosssections to be connected. With the exception of S3 MSPs which are equipped with 4 mm hexagon socket terminal screws, all terminal screws are tightened with a Pozidriv screwdriver size. The box terminals of the S3 MSPs can be removed in order to connect conductors with cable lugs or connecting bars. A terminal cover is available to help prevent contact with shock protection and to ensure that the required clearances and creepage distances are maintained if the box terminals are removed. Spring-type connection ) As an alternative to screw terminals, S00 and S0 devices are also available with Spring-type terminal connection. This screwless Spring-type terminal technique, as known for modular terminal blocks, offers shock-proof and vibration proof connection of conductors. Devices with Spring-type connection allow independent connection of two conductors per terminal. MSP with Spring-type terminal connection ) It is assumed that this circuit always provides safe cut-out, even in the event of a double earth fault that bridges two contacts. ) For notes on Spring-type terminal connection, see section 9. Siemens Canada Limited Industrial Control Product Catalog 09 /3

3RV up to 00 A Characteristics The time/current characteristic, the current limiting characteristics and the I²t characteristics were determined in accordance with DIN VDE 0660 or IEC 60 947. The tripping characteristic of the inverse-time delayed overload releases (thermal overload releases or A releases) for DC and AC with a frequency of 0 to 400 Hz also apply to the time/current characteristic. The characteristics apply to the cold state. At operating temperature, the tripping times of the thermal releases are reduced to approximately %. Under normal operating conditions, all three poles of the device must be loaded. The three main conducting paths must be connected in series in order to protect single-phase or DC loads. With -pole and 3-pole loading, the maximum deviation in the tripping time for 3 times the setting current and upwards is ± 0 % and thus in accordance with DIN VDE 0. The tripping characteristics for the instantaneous, electromagnetic overcurrent releases (short-circuit releases, N releases) are based on the rated current I n that represents the maximum value of the setting range for MSPs with adjustable overload releases. If the current is set to a lower value, the tripping current of the N release is increased by a corresponding factor. The characteristics of the electromagnetic overcurrent releases apply to frequencies of 0/60 Hz. Appropriate correction factors must be used for lower frequencies up to 6 / 3 Hz, for higher frequencies up to 400 Hz and for DC. The printed characteristic curve determined for the MSP relates to a specific setting range. It is, however, also valid as a schematic representation of MSPs with other current ranges. Typical time/current characteristic of 3RV Circuit diagrams Internal connections Motor starter protectors 3RV. /3 Siemens Canada Limited Industrial Control Product Catalog 09

3RV up to 00 A Dimension drawings 3RV MSP, size S00 3RV0 3RV0 4 49 96.9 3RV MSP, size S0 4 96.9 97 97 49 3RV MSP, size S 49.4 44.4.4 30 4.8 / L 3/ L / L3 40 30 70 / T 4/ T 6/ T3 3RV.3 motor starter protector (<= 4A) Siemens Canada Limited Industrial Control Product Catalog 09 /33

3RV up to 00 A 3RV.3 MSP, size S / L 3/ L / L3 70 49.3 44.3.4 30 4.8 40 30 / T 4/ T 6/ T3 3RV7 and 3RV8 circuit breakers, size S00, S0 and S3 3RV7, 3RV8 7 7 Ø Ø ) Mounting according to EN 607 ) Mounting to standard according mounting to EN 607 rail TH 3. to standard ) Drilling mounting pattern. rail TH 3. ) Drilling pattern. 4 4 6 ) ) 44 44 06 06 ) ) 7 4 4 4 4 4 4 NSB0_076b NSB0_076b 79 9 79 9 3RV7 circuit breakers, size S3 3RV7 4,, 6 30 Ø ) Mounting according to EN 607 on TH 3 standard mounting rail, mm deep, or TH 7 standard mounting rail. ) Drilling pattern. 4 9 68 ) ) 70 7 NSB0_03c 3 3 7 69 /34 Siemens Canada Limited Industrial Control Product Catalog 09

Mountable accessories Overview Mounting location and function The 3RV motor starter protectors/circuit breakers have three main contact elements. In order to achieve maximum flexibility, auxiliary switches, signaling switches, auxiliary releases and isolator modules can be supplied separately. Front side Note: A maximum of four auxiliary contacts with auxiliary switches can be mounted on each motor starter protector/circuit breaker. Left-hand side Notes: A maximum of four auxiliary contacts with auxiliary switches can be mounted on each motor starter protector/circuit breaker. Lateral auxiliary switches (two contacts) and signaling switches can be mounted separately or together. The signaling switch cannot be used for the 3RV7 and 3RV8 circuit breakers. Right-hand side Notes: One auxiliary release can be mounted per motor starter protector/circuit breaker. Accessories cannot be mounted at the right-hand side of the 3RV motor starter protectors for motor protection with overload relay function. Transverse auxiliary switches, solid-state compatible transverse auxiliary switches NO + NC or NO or CO Lateral auxiliary switches ( contacts) NO + NC or NO or NC Lateral auxiliary switches (4 contacts) NO + NC Signaling switches Tripping NO + NC Short circuit NO + NC Auxiliary releases Shunt releases or Undervoltage releases or Undervoltage releases with leading auxiliary contacts NO Top Isolator modules Notes: The isolator module cannot be used for the 3RV7 and 3RV8 circuit breakers. The isolator module for size S - can only be used with 3RV motor starter protectors/circuit breakers up to max. A - cannot be used with the transverse auxiliary switch The isolator module covers the terminal screws of the transverse auxiliary switch. If the isolator module is used, we therefore recommend that either the lateral auxiliary switches be fitted or that the isolator module not be mounted until the auxiliary switch has been wired. These components are easily fitted to the switches without the use of any tools according to requirements. Overview graphic, see page 7/7. An auxiliary switch block can be inserted transversely on the front. The overall width of the motor starter protectors/circuit breakers remains unchanged. One of the three lateral auxiliary switches can be mounted on the left side per motor starter protector/circuit breaker. The contacts of the auxiliary switch close and open together with the main contacts of the motor starter protector/circuit breaker. The width of the lateral auxiliary switch with two contacts is 9 mm. One lateral auxiliary switch with four contacts can be mounted on the left side per motor starter protector/circuit breaker. The contacts of the auxiliary switch close and open together with the main contacts of the motor starter protector/circuit breaker. The width of the lateral auxiliary switch with four contacts is 8 mm. One signaling switch can be mounted on the left side of each motor starter protector. The signaling switch has two contact systems. One contact system always signals tripping irrespective of whether this was caused by a short circuit, an overload or an auxiliary release. The other contact system only switches in the event of a short circuit. There is no signaling as a result of switching off with the actuator. In order to be able to switch on the motor starter protector again after a short circuit, the signaling switch must be reset manually after the error cause has been eliminated. The overall width of the signaling switch is 8 mm. For remote-controlled tripping of the motor starter protector/circuit breaker. The release coil should only be energized for short periods (see circuit diagrams). Trips the motor starter protector/circuit breaker when the voltage is interrupted and prevents the motor from being restarted accidentally when the voltage is restored. Used for remote-controlled tripping of the motor starter protector/circuit breaker. Particularly suitable for EMERGENCY-STOP disconnection by way of corresponding EMERGENCY-STOP pushbuttons according to DIN EN 6004-. Function and use as for the undervoltage release without leading auxiliary contacts, but with the following additional function: the auxiliary contacts will open in switch position OFF to deenergize the coil of the undervoltage release, thus interrupting energy consumption. In the "tripped" position, these auxiliary contacts are not guaranteed to open. The leading contacts permit the motor starter protector/circuit breaker to reclose. The overall width of the auxiliary release is 8 mm. Isolator modules can be mounted to the upper connection side of the motor starter protectors. The supply cable is connected to the motor starter protector through the isolator module. The plug can only be unplugged when the motor starter protector is open and isolates all 3 poles of the motor starter protector from the network. The shock-protected isolation point is clearly visible and secured with a padlock to prevent reinsertion of the plug. For a complete overview of which accessories can be used for the various motor starter protectors/circuit breakers, see page 7/. Siemens Canada Limited Industrial Control Product Catalog 09 /3

Mountable accessories Overview S00 and S0 motor starter protectors with mountable accessories 3 8 9 7 NSB0_0076 4 6. Motor starter protectors, sizes S or S3, with mountable accessories Mountable accessories for all sizes S00... S3 Mountable accessories for sizes Mountable accessories for sizes Transverse auxiliary switch 6. Undervoltage release with S00, S0 7 S00... S3 leading auxiliary contacts (can not be used with 3RV S, S3 3 circuit breakers) Lateral auxiliary switch with contacts Lateral auxiliary switch with 4 contacts 4 Shunt release Undervoltage release 6. Undervoltage release with leading auxiliary contacts 8 9 Signaling switch (can not be used with 3RV7 and 3RV8 circuit breakers) Isolator module (can not be used with 3RV7 and 3RV8 circuit breakers) Terminal block E S0 and S /36 Siemens Canada Limited Industrial Control Product Catalog 09

Mountable accessories Circuit diagrams Internal connections Shunt release 3RV9 0-D / 3RV9 0-D Undervoltage release 3RV9 0-A / 3RV9 0-A Undervoltage release with leading auxiliary contacts 3RV9 -C / 3RV9 -C Lateral auxiliary switch with 4 contacts 3RV9 0-J / 3RV9 0-J Transverse auxilia ry switch 3RV9 0-D 3RV9 0-D 3RV9 0-G 3RV9 0-G 3RV9 0-E 3RV9 0-E 3RV9 0-E 3RV9 0-E Lateral auxiliary switch with contacts 3RV9 0-F 3RV9 0-A 3RV9 0-F 3RV9 0-A 3RV9 0-A 3RV9 0-A 3RV9 0-B 3RV9 0-B 3RV9 0-B 3RV9 0-B 3RV9 0-C 3RV9 0-C 3RV9 0-C 3RV9 0-C SignalIng switch 3RV9 -M / 3RV9 -M External connections Shunt release Undervoltage release S0; S; S Q S F; F F3 F4 OFF pushbuttons in system Motor starter protectors Auxiliary switch of MSP Q Fuses (gl/gg) max. 0 A Shunt release Undervoltage release Siemens Canada Limited Industrial Control Product Catalog 09 /37

Mountable accessories Circuit diagrams Typical circuits 3RV MSPs with 3RV9 -M signalling switch H: "Short circuit" signal H: "Overload" or "Tripped by auxiliary release" signal H; H F Q S Indicator lights Fuses (gl/gg) max. 0 A MSP Signalling switch Separate "Tripped" and "Short circuit" signals Motor starter protectors tripped by means of pushbutton or EMERGENCY STOP button in the system The leading auxiliary contacts open in "OFF" position of the MSP to switch off the coil voltage of the undervoltage release, thus avoiding power consumption in switched off state. In the "tripped" position of the MSP, these contacts are not guaranteed to open. F; F Q F4 S; S, S3 Fuses (gl/gg) max. 0 A MSP Undervoltage release OFF pushbuttons in system Dimension drawings Isolator modules 3RV9 8-A for MSPs size S00, S0 3RV9 38-A for MSPs size S 4.8 44.7 07.9 6.9 For dimension drawings of auxiliary switches, signalling switches and auxiliary releases, see page /33 and /34. /38 Siemens Canada Limited Industrial Control Product Catalog 09

3RV Motor Starter Protectors 3RV Motor Starter Protectors up to 00 A Accessories Busbar accessories Overview The MSPs are mounted directly with the aid of busbar adapters on FastBus-busbar systems with 40 mm and 60 mm centerline spacing, in order to save space and to reduce wiring times and costs. The MSPs are snapped onto the adapter and connected on the line side. This prepared unit is then plugged directly onto the busbar system, and is thus connected both mechanically and electrically at the same time. FastBus-busbar adapters for busbar systems with 40 mm centerline spacing are suitable for copper busbars with a width of mm to mm, while those with 60 mm centerline spacing are suitable for widths of mm to 30 mm. The busbars can be 4 to mm or 0 mm thick. Refer to page /0 for busbar adapters for specific MSPs and accessories. MSPs and combination starters with FastBus-busbar adapters snapped onto busbars Further busbar adapters for snap-mounting direct-on-line starters and reversing starters, as well as additional accessories such as line terminals and outgoing terminals, busbar copper, etc., can be found in Section. Insulated three-phase busbar system 8US busbar adapters for 60 mm systems Three-phase busbar systems provide an easy, time-saving and clearly arranged means of feeding 3RV motor starter protectors with screw terminals. They can be used for the different types of motor starter protector up to 3 A. The 3RV9 three-phase busbar systems are generally unsuitable for the 3RV motor starter protectors for motor protection with overload relay function and for the 3RV7 and 3RV8 circuit breakers according to UL 489 / CSA C. No. -0. The motor starter protectors are mounted directly with the aid of busbar adapters on busbar systems with 60 mm center-to-center clearance in order to save space and to reduce infeed times and costs. The busbars are suitable for between and circuit breakers/motor starter protectors. However, any kind of extension is possible by clamping the tags of an additional busbar (rotated by 80 ) underneath the terminals of the respective last motor starter protector. A combination of motor starter protectors of different sizes is possible. The motor starter protectors are supplied by appropriate feeder terminals. The busbar adapters for busbar systems with 60 mm center-tocenter clearance are suitable for copper busbars with a width of mm to 30 mm. The busbars can be mm or 0 mm thick. The motor starter protectors are snapped onto the adapter and connected on the line side. This prepared unit is then plugged directly onto the busbar system, and is thus connected both mechanically and electrically at the same time. For further busbar adapters for snap-mounting direct-on-line starters and reversing starters as well as additional accessories such as line terminals and outgoing terminals, flat copper profile, etc., can be found in Section. 3RV9 -AB 3RV9 -CB NSB0_0080 NSB0_0079 3RV9 -B 3RV9-6AB three-phase busbar system size S00/S0 load feeders with busbar adapters snapped onto busbars The three-phase busbar systems are finger-safe. They are designed for any short-circuit stress which can occur at the output side of connected motor starter protectors. The three-phase busbar systems can also be used to construct Type E Starters according to UL/CSA. Special feeder terminals must be used for this purpose however (see Selection and Ordering Data on page /8). Siemens Canada Limited Industrial Control Product Catalog 09 /39 Busbar adapters