Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

Similar documents
REPLACEMENT PARTS MANUAL

GROUND SOURCE and GROUND WATER SOURCE HEAT PUMP REPLACEMENT PARTS MANUAL. General Notes. Contents. Important

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

ELEMENTARY DIAGRAM CONNECTION DIAGRAM CONTROL PANEL AND CONNECTION DIAGRAM SYSTEM WIRING FOR MODELS:

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

Air-Cooled Scroll Compressor Chillers Models AGZ 010A to AGZ 034A Models AGZ 026B to AGZ 130B. Revised Electrical Data Tables.

Pretest Module 24 Three-phase Service Entrance

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz)

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

RWT Series Water-to-Water Heat Pumps & Hydronic Air Handlers / A Coils: Engineering Data and Installation Manual

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

GSC13 Split System Air Conditioner

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

Specification Manual

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

Installation Instructions

Quick Connection Panel (QCP) Installation Guide

CKL SERIES 10 SEER PRODUCT SPECIFICATIONS. Split System Air Conditioner. 1½ to 5 Ton

Installation Instructions

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Installation Instructions

YCAL0014E_ - YCAL0124E_ R-22 & HFC-407C STYLE C (60 Hz)

TECHNICAL SPECIFICATIONS

Installation Instructions

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

ARUF Series Multi-Position

FIELD CONNECTIONS MODEL YK CHILLERS (STYLE F AND G) WITH VARIABLE SPEED DRIVE

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

Installation Instructions

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner

Quik-Spec Coordination Panelboard Specifications

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

ZHA/ZHB SERIES WARNING

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

Wiring Diagrams DIAGRAM INDEX

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

SAVE THESE INSTRUCTIONS

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

Installation Instructions Electric Heaters 5 20 kw

ANZI Transfer Switch and Generator Wiring Installation Addendum

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

A WORD ABOUT PROPER GROUNDING

Approved Contractor Construction e-guide Residential Commercial

Mizer Single Pump and Starter Box

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

Electric Motor Controls BOMA Pre-Quiz

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

TSA6. Product Specifications. SmartComfort TXC 5600

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h


AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS

Replacement Parts, W/D & Tech Data CAC Series

AMENDMENT ELECTRIC SERVICE MANUAL 2014

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Engineering Data Submittal Manual

Controls Manual Standard 1 Fan Control Panel

AWUF, AWUT Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

OnCommand Troubleshooting Guide Hayward Industries

Starters for Centrifugal Chillers

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

Electrical Components

INSTRUCTION MANUAL IM260 AQUAVAR SOLO 2 CONSTANT PRESSURE CONTROLLER INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

WIRING DIAGRAM MODEL YK (STYLE G) LIQUID CHILLERS OPTIVIEW CONTROL CENTER WITH ELECTRO-MECHANICAL STARTER

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

WATER SOURCE HEAT PUMPS

FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

JS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase. Cooling Capacity: 36,000-60,000 BTU/h

Electrical Depth. Mark W. Miller Sibley memorial Hospital Grand Oaks Washington, DC CURRENT SYSTEM

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner. Cooling Capacity: 36,000-60,000 BTU/h

NORTHERN HEAT PUMP INC.

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

Quick Start Guide TS 910

Owner's/Installation Manual

Installation Instructions Electric Heaters 5 20 kw

Transcription:

Installer Water to Water Geothermal Heat Pump 3-Phase s Both 208 & 480 Installation Instructions : THA-***-2 (208, 3-Phase) THT-***-2 (208, 3-Phase) THA-***-3 (480, 3-Phase) THT-***-3 (480, 3-Phase) This manual provides the changes in electrical installation and is an addition to the standard GI101 Installation & Operating Instructions. This additional document only replaces GI101 pages 5, 26 and 45. All general information, mechanical details and installation, general operating and troubleshooting, etc. is the same for all models. DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICE TECHNICIAN. Important information Number: Serial Number: Installing Contractor: 10/12/2012 GI102

THA-*** Electrical Data Three-Phase, 208 (60 Hz) RLA LRA FLA FLA FLA FLA Ampac- THA-036 200/230-3 13.5 88 1.8.15 4.4 19.9 23.2 30 THA-048 200/230-3 17.6 123 1.8.15 4.4 24.0 28.4 40 THA-060 200/230-3 20.5 155 1.8.15 4.4 26.9 32.0 50 THA-072 200/230-3 23.2 164 1.8.15 4.4 29.6 35.4 50 THT-*** Electrical Data Three-Phase, 208 (60 Hz) RLA LRA FLA FLA FLA FLA Ampac. THT-096 200/230-3 17.6 x 2 123 x 2 1.8.15 4.4 24.0 x 2 28.4 x 2 40 x 2 THT-120 200/230-3 20.5 x 2 155 x 2 1.8.15 4.4 26.9 x 2 32.0 x 2 50 x 2 THT-144 200/230-3 23.2 x 2 164 x 2 1.8.15 4.4 29.6 x 2 35.4 x 2 50 x 2 THA-*** Electrical Data Three-Phase, 480 THA-036 THA-048 THA-060 THA-072 (60 Hz) RLA LRA FLA FLA FLA FLA Ampac. THT-*** Electrical Data Three-Phase, 480 (60 Hz) RLA LRA FLA FLA FLA FLA Ampac. THT-096 THT-120 THT-144 460/480 15 x 2 75 x 2 20 x 2 Notes: 1. Dual compressor models contain dual power circuits for the compressors, amperages shown are for each circuit. 2. All 3-phase models have 120V service source for internal control transformer and outputs for pumps. Thus the only current/power from the 3-phase source is the compressor. 10/12/2012 1 GI102

Electrical Hookup 3-Phase s Both 208 and 480 DISCONNECT ALL ELECTRICAL POWER BEFORE ELECTRICALLY CONNECTING OR SERVICING THE UNIT. FAILURE TO DISCONNECT THE ELECTRICAL POWER BEFORE WORKING ON THIS PRODUCT CAN CREATE A HAZARD LEADING TO PERSONAL INJURY OR DEATH. Compressor Power Source 3-Phase The nameplate and/or Installation and Operating Manual specification page provides RLA, LRA, and total amps requirement. Select the proper wire size to comply with your type of wire routing and NEC field wiring requirements. The field power supply connection is located at the compressor contactor in the lower right hand corner of the control box. Dual compressor models have separate contactors that feed each compressor individually. A dedicated circuit must be fed to each contactor, see electrical data chart for circuit breaker requirements. USE ONLY COPPER WIRE FOR CONNECTION TO THE CIRCUIT BREAKER TERMINALS AND INSIDE THIS PRODUCT S CABINET. Disconnect field provided external safety disconnect is required, see nameplate max amps. Grounding route and install the proper size ground conductor between the ground lug above the compressor contactor and the building service entrance panel ground bus. This must be a conductor wire size according to NEC code for the total amp rating of the installed model. The conduit is not sufficient ground conductor. TO AVOID THE RISK OF ELECTRIC SHOCK OR DEATH, WIRING TO THE UNIT MUST BE PROPERLY GROUNDED. FAILURE TO PROPERLY GROUND THE UNIT CAN RESULT IN A HAZARD LEADING TO PERSONAL INJURY OR DEATH. Note: Some local codes and CEC electric code may require single disconnect and single feed for the main compressor power source. If this is the case, the installer must provide disconnect with multi-feeds per above. DISCONNECT ALL POWER SOURCES BEFORE OPENING OR SERVICING COMPRESSOR POWER FEED, 120 CONTROL SERVICE, EXTERNAL PUMP RELAYS, ETC. 10/12/2012 2 GI102

120 Control Service these models require a 15-amp (minimum) standard general service 120 source. See below for hookup and appropriate servicing disconnect switch should be field installed external to the main geo cabinet. This 120 source is used for the control transformer and outputs 120VAC for both the source and load pumps. Each pump output is internally fused at 10 amps. Comment if either external pump requires a different voltage or power hookup, use 120V relay coil connected to the terminal block. The line voltage relay contacts can then apply the voltage required by the pumps being used at the specific installation site. Single Compressor s 2.5 through 6-ton Dual Compressor s 8 through 12-ton 10/12/2012 3 GI102

Troubleshooting Main THA/THT manual, page 45 this is a rewrite for 120V control and external pump source. Troubleshooting the pump relay board The pump relay board has 4 LED s which display which relay is closed. Yellow is on when open loop water solenoid is energized. Green is on when the source and load pumps are energized. Red is on when the desuperheater pump relay has SWH terminal energized.. Blue is on when the 2 nd source loop pump is energized. The relay board has a 15 amp fuse providing power for source loop, hydronic, and the desuperheater pumps. This is a standard inline, 1-¼ x 1, 3AB. Checking the high voltage input terminals The high voltage enters the pump relay board on the upper left side, terminals W1 & W2. This high voltage comes from the external 120V service. DISCONNECT ALL ELECTRICAL POWER BEFORE ELECTRICALLY CONNECTING OR SERVICING THE UNIT. FAILURE TO DISCONNECT THE ELECTRICAL POWER BEFORE WORKING ON THIS PRODUCT CAN CREATE A HAZARD LEADING TO PERSONAL INJURY OR DEATH. Checking the high voltage output terminals The high voltage leaves the pump relay board in 2 locations. 1. Terminal Block (TB1) is located in the upper right side of the pump relay board. See the decal located to the right of the TB1 to determine wiring. High voltage should be present at the respective terminals when the corresponding LED is on Load pump terminals will be hot at the same time as source pump terminals. Tip if source voltage is present on the board W1, one of the LEDs is on, and high voltage is not present at the corresponding terminals, the switching relay is bad and the board will need to be replaced. 2. One of the desuperheater terminals (SWH) is located between the fuses and the other SHW terminal is below the fuses. These terminals carry High Voltage. To determine if the desuperheater pump has power measure across these two terminals. If a desuperheater pump needs to be disabled be sure the high voltage to the TTHERM GEO heat pump is disabled. Remove the SHW wire and place it on the parking tab (P) above the relays. The pump relay board has one low voltage output for the 24 volt AC water solenoid. The 24VAC common wire is gray and is connected to terminal T7 on the right side of the pump relay board. The 24VAC hot wire is brown/yellow and is connected to terminal T4. Tip if the yellow LED #4 is on and the low voltage is not present at the water solenoid terminals, the switching relay is bad and the board will need to be replaced. 10/12/2012 4 GI102