COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

Effective June 2016 New Issue

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

Effective March 2015 Supersedes S August 2012

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

High-voltage primary bushings installation instructions

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

Type NR oil switch installation and operation instructions

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

Effective May 2017 Supersedes December 2004 (S )

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

Figure 1. Kearney Type HX cutout.

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Factory Authorized Mechanism Enhancement (FAME)

CCP2-FLR1-21_ flange-rod operating mechanism

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Two-way cable interlock kit for Magnum fixed circuit breakers

3-way multi-family drawout cable interlock kit - type 32 - RF

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Two-way cable interlock kit for Magnum drawout circuit breakers

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

Instruction Booklet IB E. Contents

CM52 Network Protector with Arc Flash Reduction Module

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Effective October 2016 Supersedes January 2014 (S )

Installation Instructions For Motor Control Center (MCC) Units

COOPER POWER SERIES. RVAC Fluid-insulated Vacuum Switchgear; Installation, Operation, and Maintenance Instructions. Switchgear MN285005EN

O & M Manual for the EATON Generator Ready Loadcenter

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Flush Mount AIN ALPHA Meters. General. Hardware Kit

COOPER POWER SERIES. Type MOST Fluid-Insulated Switchgear; Installation, Operation, and Maintenance Instructions

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

MaxLite StaxMax LED Flood Lights

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

Instructions for using Functional Test Kit on Digitrip 520 and 1150 family of Power Circuit Breaker Trip Units and Series G and FD MCCB Trip Units

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

SPX9000 FR10 FR12 Adjustable Frequency Drives

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

600 A 15 and 25 kv class Cleer grounding elbow

Advanced Test Equipment Rentals ATEC (2832)

38 kv Type VCPW-HD Simple Electrical Ground & Test Device (SEG&TD) lower terminal instruction booklet

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

ELF -LR current-limiting fuse

Transcription:

Fusing Equipment MN132018EN Effective November 2016 Supersedes September 1998 (S240-84-1) X-Limiter Hinge-Mount for S&C SMD -20 Fuse Mounting Assembly and Installation Instructions COOPER POWER SERIES

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... ii SAFETY FOR LIFE... iv SAFETY INFORMATION... iv Safety instructions...iv PRODUCT INFORMATION.... 1 Introduction...1 Retrofit installation of X-Limiter hinge-mount fuse...1 Fuse Replacement...2 iii

X-Limiter Hinge-Mount for S&C SMD -20 Fuse! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around highand low-voltage lines and equipment. G103.3 WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.2 iv

X-Limiter Hinge-Mount for S&C SMD -20 Fuse Product information Eaton s Cooper Power series X-Limiter Hinge-Mount fuse is designed to be installed in accordance with normal safe operating procedures. These instructions are not intended to supersede or replace existing safety and operating procedures. READ ALL THE INSTRUCTIONS BEFORE INSTALLING THE X-Limiter Hinge-Mount fuse. The Hinge-Mount fuse should be installed and serviced only by personnel familiar with good safety practice and the handling of high-voltage electrical equipment. Introduction The X-Limiter Hinge-Mount, Full Range current-limiting fuse has been adapted to fit the S&C SMD -20 cutout mounting. The use of the S&C standard end fittings allow for complete interchangeability with fuses mounted in S&C SMD-20 cutouts. Upper End Fitting Clamp Screw Locating Pin Actuating Pin Through Upper Seal When Fuse Unit Is Blown Full-Range Current-Limiting Fuse Current Transfer Surface Upper Seal Locating Slot Do not install fuse units if the blown fuse indicator has been damaged or destroyed, as the fuse s moisture seal will be damaged, which may cause fuse failure. Retrofit installation of X-Limiter hinge-mount fuse Initial retrofit installation includes removing the existing fuse from the S&C SMD-20 cutout and replacing it with the X-Limiter fuse in accordance with the following steps. 1. Removal of fuse in the S&C SMD-20 cutout: A. The fuse will be in an open position after it has operated. Remove it from the mounting using a standard insulated hotstick. B. Loosen the upper- and lower-end fitting-clamp screws. With a screwdriver, force the upper-end fitting clamp apart slightly, and slide both end fittings off the upper end of the fuse unit. C. Save the end fittings for use with the X-Limiter fuse. Inward Dimple Clamp Pad Lower End Fitting Locknut Notch Clamp Screw Figure 1. Line illustration of X-Limiter hinge mount for S&C SMD-20 fuse mounting. 2. Assembly of X-Limiter hinge-mount current-limiting fuse: When shipped from the factory, the X-Limiter fuse will be readily equipped for installation. 3. Attachment of end fittings on the X-Limiter fuse: A. The lower end fitting must be attached first. The X-Limiter fuse has a notch in the bottom which receives the S&C end fitting wedge. Care must be taken to hand tighten the bolt such that the end fitting wedge is in the fuse notch. When properly installed, the bottom of the fitting is even with the bottom of the fuse, to about 1/8 above the bottom of the fuse, and the inward dimple is centered and visible on the opposite side of the fittings. (Location of notch and inward dimple are shown in Figure 1.) When the end fitting is properly located tighten the clamp screw and locking nut securely. If upper and lower contacts are not properly aligned DO NOT FORCE. Loosen clamp screws and realign. B. Slide the upper end fitting over the X-Limiter fuse. Align the locating pin inside the end fitting with the locating slot of the fuse and slide it down. When the locating pin is placed in the slot, tighten the clamp screw securely. (Refer to Figure 1.) 1

X-Limiter Hinge-Mount for S&C SMD -20 Fuse In accordance with Figure 2, verify that gaps are eliminated between the top of the upper-end fitting and the upper seal on the fuse. Gaps may cause latch failure. Top Upper-End Fitting Gap 4. Installation of X-Limiter hinge-mount fuse with end fittings into SMD-20 cutout: Refer to manufacturer s operating procedure for installation of fuse into cutout. Fuse Replacement When the X-Limiter hinge-mount fuse clears a fault, the actuating pin causes the fuse to drop open. For removal and installation of a new X-Limiter hinge-mount current-limiting fuse, follow the steps outlined on page 1, Retrofit installation of X-Limiter hinge-mount fuse. Upper Seal on Fuse Figure 2. Illustration of gap at top upper-end fitting. 2

X-Limiter Hinge-Mount for S&C SMD -20 Fuse T his page is intentionally left blank. 3

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2016 Eaton All Rights Reserved Printed in USA Publication No. MN132018EN Rev. 0 November 2016 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.