Series 8000 Vortex Flow Meter

Similar documents
Ultrasonic Flow Meter Series Smart-IN US. Features. Description

Vortex Eggs Delta Flowmeter

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter

F-2500 SERIES VORTEX METER

F-2600 SERIES INLINE VORTEX FLOW METER

Armstrong In-Line and Insertion Vortex Flow Meters

Thermal Gas Mass Flowmeter Series TMF-300

4-20mA, pulse with HART or pulse with RS485 are selectable. No moving parts, no abrasion, non-wearing parts inside, fully welded SS304

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

STEEMCO-MAS Flowmeter for Steam

CATALOG KVFN. Vortex Flowmeter

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Vortex In Line Flow Meter

Flange connection type vortex flowmeter. Flange card type vortex flowmeter. Temperature-pressure compensation type. Insertion type vortex flowmeter

VORTEX IN-LINE FLOW METERS

Vortex Flow Meter Model DVH

CATALOG KVFN. Vortex Flowmeter

Vortex In Line Flow Meter

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Model 5000 Vortex Meter

F-2600 SERIES INLINE VORTEX FLOW METER

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

VIM20 Vortex Insertion Flowmeter

F-2700 SERIES INSERTION VORTEX FLOW METER

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

VIM20 Vortex Insertion Flowmeter

Model 1000 Vortex Meter

VLM20 In-line Vortex Flowmeter

CATALOG KTLU. Vortex Flowmeter

VersaFlow Vortex 100 Vortex Flow Meter Specifications

mass flowmeter for compressed air

STEEMCO Flowmeter for Steam

VIM20 Vortex Insertion Flowmeter

Transmitting Transducer. Gas/Air Velocity Range:

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Flange connection type vortex flowmeter. Flang card type vortex flowmeter. Temperature-pressure compensation type. Insertion type vortex flowmeter

F-2700 SERIES INSERTION VORTEX FLOW METER

SIGNET 7002 Vortex Flow Sensor ENGLISH

Fundamental Training. Flow Con t

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

mass flowmeter for compressed air

Instruction manual. Ultrasonic Level Transmitter (ULT) ientek Co., Ltd. ientek Co., Ltd. Ultrasonic Level Transmitter OE

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Vortex Flowmeter Model DVE

Hot Tap Insertion Vortex

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

ORIMAS Mass Flowmeter

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

Hydro-Flow Model 2300 Installation and Operation Guide B

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

The readings you need, right where you need them. AX Series Vortex Meters

Instruction manual. Smart Thermal Mass Flow Meter. TYPE : 3000S Series. ientek Co., Ltd.

Hydro-Flow Model 2200 Installation and Operation Guide B

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

SITRANS FX300 4/289. System Overview. Overview

OPTISWIRL 4070 Technical Datasheet

Vortex Plate. Model VP General Specification. Product Features

Hydro-Flow Model 3100

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Low Profile Insertion Vortex

RCM - Direct Reading Flowmeters

F-1500 SERIES INSERTION TURBINE FLOW METER

DY-LWGY Liquid turbine flow meter

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

RIM20 Rotor Insertion Flowmeter

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

Model FVP General Specification. Flanged Vortex Plate. Product Features

The readings you need, right where you need them. AX Series Vortex Meters

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

OPTISWIRL 4070 Technical Datasheet

Insertion magnetic inductive flowmeter

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

EU 108 Separated Fixed Ultrasonic Flowmeter

SRT1000 Series THERMAL FLOWMETER

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON

Magnetic Inductive Flowmeter EP / UMF2 (B)

Stainless steel(compensation) DN25, 40, Flange Standard GB/T Others DIN,ANSI,JIS Thread Standard BSPP(male) Others BSPP(Female),NPT.,etc. A

ISTEC MAGNETIC METERS

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

PFA Eddysonic flowmeter

유량계전문제조업체. Electro Magnetic FLOWMETER

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Liquid Turbine Flow Meter OwnerÊs Manual

LBTC Series Positive Displacement Rotary Vane Flow Meters

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Water Solutions For Global Needs

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Conserving Energy Since 1946 VFM Technical Data. Vortex Flowmeter

C-7200 Series Smart-IN US Ultrasonic Flow Meter C Ultrasonic Flow Meters. Ultrasonic Flow Meter

FLOWMETER (SMALL CAPACITY) METER SIZE 80, 81

Transcription:

VFM Series 8000 Vortex Flow Meter Operating Principle The operation of the VFM 8000 is based on the Karman Vortex Street. Vortices are formed as the fluid flows around the shedder body which are alternately shed from its sides. The flow causes these vortices to be released forming a vortex street (Karman Vortex Street), see Fig.2. Fig. 2 Measurement Principle 8000 VFM The frequency f of the vortex shedding is proportional to the flow velocity v and inversely proportional to the width of the shedder body d: v f = Sr x d Sr, the Strouhal Number, a dimensionless number, defines the quality of the vortex flowrate measurements. By appropriate design of the shedder body, Sr is constant over a wide Reynolds Number Re range (Fig. 3). v x D Re = v v = Kinematics viscosity D = Meter tube diameter Fig. 3 Strouhal No. / Reynolds No. Relationship As a result, the vortex shedding frequency to be evaluated, is only a function of the flow velocity and is independent of the fluid density and viscosity. The local pressure changes resulting from the vortex shedding are detected by a Piezo sensor and converted into electrical pulses corresponding to the vortex shedding frequency. The flowrate proportional frequency signal generated in the flowmeter primary is processed in the converter into a current output (4-20 ma) signal. 1

Features The Ratio is big, the accuracy is high and the press drop is few, the medium popular use characteristic is good. There is pulse signal output and it is possible to connect at computer and use it. Sensing parts vortex shedder body and separation saddle. The inside high temperature piezo crystal does not contact measurement medium, so the flow meter structure is simple, the popular use characteristic is good and the stability is high. It will be able to use various gas and the liquid Steam flow rate inspection and calculation. Using together computer, temperature, pressure and the density sensor, high precision mass flow rate or it will be able to create a calorie flow rate inspection weighting system. Applications Gas measurement at LNG yard At an LNG yard, LNG and LPG unloaded from carrier tankers are accepted as raw materials, gas tide and then sold to town gas companies and large users. VFM 8100 and other ientek meters are applicable to gasifying lines, steam lines and many other uses. Air conditioning steam measurement Calorific consumption in steam heating is normally calculated for business transactions by metering the quantity of returned condensation with ientek flow meter. On the other hand, utility steam consumed in room humidification, heating, of cleaning is sold directly through VFM 8100. 2

Energy measurement in the cleanings and drying processes of assemblies In the cleaning process of automotive assemblies and subassemblies in the manufacture of motor vehicles of other machines, work is exposed to cleansing solutions sprayed form nozzles and then exposed to large quantities of dry air directed to accelerate the drying step. Here, the VFM 8100 plays an important role of metering the quantities of steam used for heating the solutions as well as those of the drying air, thus contributing to precise energy cost control and saving. Specifications Measurement Medium : Various Gas and Liquid, Steam Pipe Size(DN) : 25~1000mm Accuracy : 1.0%, 0.5%(Custom-built), Insert : 2.5% Medium & Ambient Temperature : Medium... -40 to 662 (-40 to 350 ) Ambient... -40 to 131 (-40 to 55 ) Relative Temperature... 5%~90% Linearity : ±1.0% Repeatability : 0.5% Standard Pressure : 2.5Mpa, 4.0Mpa, 6.9Mpa (Special Custom-built) Output Signal : Current pulse, low level 4±0.5mA, high level 20±lmA Power Requirements : 24V DC Load Capacity : 350Ω Connection Method : Flange, wafer type, Insert type ( 250mm) Wetted Materials : ICr18Ni9Ti Enclosure : IP65 Explosion Class : iaⅡct1~6(nature safety) Safety barrier power distribution unit DⅡBT4 Power supply Power Relation Equipment : 1 Local Indicator/Totalize 3 LCD Computer 5 Power Mounting Indicator/Totalize 2 Panel mounting Indicator/Totalize 4 Power Supply Unit 3

Flow Ranges Table 1. Flow rate range Sensor Model DN Flow rate range(m 3 /h) (mm) Liquid Gas Steam Sensor Model DN Flow rate range(m 3 /h) (mm) Liquid Gas Steam VFM 25 1~10 10~97 9~80 VFM 300 100~1600 1500~15000 1200~12000 VFM 40 2~30 24~230 20~190 VFM 350 140~2000 2000~20000 1620~16200 VFM 50 3~40 40~370 30~300 VFM 400 180~2700 2700~27000 2100~21000 VFM 65 5~70 63~630 50~500 VFM 500 280~4000 4230~42300 3300~3000 VFM 80 7~100 97~970 80~800 VFM 600 400~6000 6100~61000 4780~47800 VFM 100 10~160 152~1520 125~1250 VFM 700 550~8300 8300~83000 6500~65000 VFM 125 20~260 240~2430 200~2000 VFM 800 720~10800 10850~108500 8500~85000 VFM 150 25~370 350~3500 280~2800 VFM 900 710~13700 13740~137400 10700~107000 VFM 200 50~720 660~6600 540~5400 VFM 1000 1100~16900 16900~169000 13200~132000 VFM 250 80~1100 1000~10000 850~8500 The parameter means is an actual flow rate range and a medium viscosity, pressure, density and temperature all relationship. It refers, it wishes. Dimension Figure 1. 8100 Series Wafer Type Table 2. VFM 8100 Series Wafer Type size(mm) DN Inner Wafer Type Body dia. L Outer D H 25 25 80 76 344 40 39 80 76 335 50 49 80 86 346 65 64 80 102 362 80 79 80 112 374 100 99 80 132 395 125 125 80 175 433 150 149 80 202 458 200 207 100 258 515 250 259 120 311 568 300 309 140 362 618 PS: (1) Measurement medium steam one case H (60mm) increase. There are shedder bodies. (2) By a user request Flange type body production possibility. 4

Figure 2. 8300 Series Insert Type Size Table 3. VFM 8300 Series Insert type size(mm) DN(mm) H(mm) dia Non ball valve Ball valve 250 300 ~600 ~825 350 400 ~650 ~875 500 600 ~750 ~975 700 800 ~850 ~1075 900 1000 ~950 ~1175 Figure 3. Flange Dimensional 5

Table 4. P N 2.5Mpa Saddle flange and dual head bolt size table (Size unit:mm) Size (DN) D D1 D2 D3 D4 D5 D6 n δ b Dual head bolt standard = bolt outer Diameter x thread length x bolt length 25 25 145 110 85 77 33 18 4 2 18 M16 x 35 x 165 40 39 145 110 85 77 46 18 4 3 18 M16 x 35 x 165 50 49 160 125 100 87 58 18 4 3 20 M16 x 35 x 165 65 64 180 145 120 103 74 18 8 3 22 M16 x 35 x 165 80 79 195 160 135 113 90 18 8 3 22 M16 x 35 x 165 100 99 230 190 160 133 109 23 8 3 24 M20 x 35 x 180 125 125 270 220 188 176 134 25 8 3 26 M22 x 40 x 190 150 149 300 250 218 203 161 25 8 3 28 M22 x 40 x 190 200 207 360 310 278 259 221 25 12 3 30 M22 x 40 x 210 250 259 425 370 332 312 275 30 12 3 32 M27 x 50 x 240 300 309 485 430 390 328 328 30 16 4 36 M27 x 50 x 270 Table 5. P N 4.0Mpa Saddle flange and dual head bolt nut size table (Size unit:mm) Size (DN) D D1 D2 D3 D4 D5 D6 n δ b Dual head standard = bolt outer Diameter x thread length x bolt length 25 25 145 110 85 77 33 18 4 2 18 M16 x 20 x 165 40 39 145 110 85 77 46 18 4 3 18 M16 x 25 x 165 50 49 160 125 100 87 58 18 4 3 20 M16 x 25 x 165 65 64 180 145 120 103 74 18 8 3 22 M16 x 25 x 165 80 79 195 160 135 113 90 18 8 3 24 M16 x 25 x 170 100 99 230 190 160 133 110 23 8 3 26 M20 x 30 x 180 125 125 270 220 184 176 140 27 8 3 28 M24 x 35 x 190 150 149 300 250 218 203 161 27 8 3 30 M24 x 35 x 190 200 207 375 320 282 259 222 30 12 3 38 M27 x 35 x 240 250 259 445 385 345 312 278 34 12 3 42 M30 x 40 x 270 300 309 510 450 408 363 330 34 16 4 46 M30 x 40 x 290 Saddle indicating drawing Figure 4. Standard saddle drawing 6

Figure 5. Where flow straightened is used Figure 6. Pressure gage & Thermometer Installation. Table 6. Up & Down Stream Requirements. 7

Wiring Connection Figure 7. VFM 8000 Series and XSJ/XSJB wiring connection Figure 8. VFM 8000 Series Explosion place wiring connection Figure 9. VFM 8000 Series wiring Terminal drawing 8

ientek Co., Ltd. Factor 2 (P)153-803 Daeryung Technotown 5th #407 493, Gasan-dong Gumcheon-Gu Seoul, Korea TEL : +82(2)-2107-7999 FAX : +82(2)-2107-7990 www.flowcountry.com, www.flowcountry.co.kr Order Information Sheet(OIS) VFM 8000S Vortex Flow Meter Type Fluid Pipe Size Material Power Output Display Temp. Pressure Option VFM 8 P V 1 2 3 4 5 6 7 8 9 10 Model Direction Code 1 Input Power Code 5 Wafer Type 100 DC24V ±10% 2 Flange Type 200 Agency approved, customer specified W Insert Type 300 Agency approved, customer specified W Output Code 6 Pulse 1 Fluid Type and saddle method Code 2 Pulse, 4-20 ma (Optional) 2 Liquid Wafer Type 00 4-20 ma 3 Gas Wafer Type 01 Agency approved, customer specified W Steam Wafer Type 02 Gas, Liquid Insert Type 10 Display Code 7 Steam Insert Type 11 No Readout NR Other(Optional) Flange Type 20 Digital Display (Optional) DD Agency approved, customer specified WW Agency approved, customer specified WW Pipe Size DN(mm) Temperature Code 8 DN(mm) Code 3 DN(mm) Code 3-40 ~200 (-40 ~392 ) T1 25 2 300 30 200 ~350 (392 ~662 ) T2 40 4 350 35 Agency approved, customer specified WW 50 5 400 40 65 6 500 50 Pressure Code 9 80 8 600 60 2.5Mpa 1 100 10 700 70 4.0Mpa 2 125 12 800 80 6.9Mpa 3 150 15 900 90 Agency approved, customer specified W 200 20 1000 100 250 25 Option Code 10 XSJ Flow rate totalize meter XSJ Material Code 4 24VDC Supply Unit DC Carbon Steel C Flange Type FL Stainless Agency approved, customer specified S WW 9