The Intelligent Power Selector (IPS) converts any conventional Inverter into a Solar Inverter. With IPS Product Series we are targeting large customer base of existing installed home UPS & Inverters to convert them to Solar Inverter. Our IPS solution will assist in reducing electricity bills & ensure a dependable back up system, contribute proudly to clean environment. The product can be customized for many other applications beyond the Inverter. It is also a self-sufficient solar DC power system
By adding IPS to your normal inverter, you will get all the features of our smart solar inverter in your converted inverter system which can be used in home and street lighting applications. It provides the facility to charge the battery bank either through Solar or Grid(Priority will be to Solar )The IPS continuously monitors the state of Battery Voltage, Solar Power output and the loads. When the Batteries are charged above a preset level, the Grid power supply to the IPS automatically cuts off from the system, in the presence of solar. The IPS is designed to give priority to solar power first and use Grid power only when the Solar power / Battery charge is insufficient to meet the load requirement. It switches to Grid charging automatically Due to sustained usage of power, when the Battery Voltage falls below a preset level, the IPS transfers the load automatically to the Grid power and also charges the Batteries through the Inverter in-built Solar /Grid Charger. The salient features include: Maximization of Solar Energy Harvest Higher Power Conversion Efficiency Universal Inverter / UPS compatibility Affordable Roof top solar system solutions Lower Electricity Bills Dependable back up system Integrated high efficiency solar charge controllers These can be used in wide-ranging applications in solar systems such as Industrial Power plants, Rooftop Solar Banking power, Water pumps or simply home & office UPS systems. Features 1) Live usage when battery is fully charged from sunlight. 2) Smart backup of 3-5 hours from battery, when power is not available 3) Fully automatic operations. 4) Long life (Life of solar panels are more than 25 years) 5) Display as well as LED to indicators to observe the working status, Solar Power generation (in watts),operations modes etc. 6) Maximum usage of solar power. 7) Effective Power Management. 8) Two Ways of Power Selection a) Automatic Power Selection (Mains or Solar) b) Manual Power Selection (For Mains Power)
The Intelligent Power Selector Models:: Product Battery Voltage (V) Solar Charging Current (I) Max Voc per PV Input (V) Max Input Wp per input (WP) IPS1220 12.00 20.00 30.00 300 IPS1240 12.00 40.00 30.00 600 IPS2420 24.00 20.00 50.00 500 IPS2440 24.00 40.00 50.00 1000 IPS3620 36.00 20.00 70.00 800 IPS3640 36.00 40.00 70.00 1000.00 IPS4820 48.00 20.00 100.00 1000.00 IP4840 48.00 40.00 100.00 2000.00 IPS4860 48.00 60.00 110.00 3000.00 IPS9620 96.00 20.00 200.00 2000.00 IPS9640 96.00 40.00 200.00 4000.00 IPS12040 120.00 40.00 200.00 5000.00
VITRONICS CONTROLS PUNE Comparison between Powerline IPS (to convert any Inverter/UPS in to Solar PCU) & Same type of Products available in market Details Powerline IPS(S Series) Same type of product available in Market Drawback in Market Products Models Available 12 V to 240 V D.C Limited Models Limited Choice 20 to 60 Amp Battery Charges Simultaneously from Mains (Grid) & Solar No Yes Battery Overcharges Effect on Battery Life No effect Reduces battery life Repeated recurring charges Effect on Inverter Life Increase Inverter Life Reduces Inverter Life High risk of recurring cost Effect on Electricity Bill Reduces Increase Additional recurring cost Display to monitor technical Parameters including solar power generation (in watts) Available Usually not available Can t measure generation of solar power Suitable to install any make Inverter/UPS Yes For limited models Limited choice During monsoon, option to charge battery through mains supply Yes Always charges battery through Mains & Solar Battery Overcharging possibility Inverter will start functioning on battery mode if full charged through solar only or when mains supply is not available* Yes No. Inverter starts working on battery mode whenever the battery gets full charged either by mains or solar Increases Electricity Bill
VITRONICS CONTROLS PUNE 3 2 Led1 4 5 6 7 8 Selector Switch A1 A2 C1 C2 C3 C4 N/O N/C Common B1 B2 Display
VITRONICS CONTROLS PUNE Understand The IPS (S Series) Led 1) Mains Present 2) Load working on Solar 3) Battery Charging by Solar 4) Battery High 5) Battery Low 6) Will indicate Solar Voltage 7) Will indicate Battery Voltage 8) Will indicate generation of solar power (Battery Voltage X Total Current form solar panel) Terminal Strips A : Solar Input (Connect Wires from Solar Panel to this strip) A1) Solar Positive (Wire from solar panel positive A2) Solar Negative (Wire from solar panel Negative B : Battery (Connect wires from this strip to battery with proper polarities) B1) Battery Positive (Connect wire from this terminal to battery positive) B2) Battery Negative (Connect Wire from this terminal to battery Negative) C : Mains (EB)/ Load / Inverter connections ( 4 Pin Terminal Strip) C1) Inverter Phase C2) Load Phase C3) Mains Phase C4) Neutral D : Inverter Control Strip ( 3 Pin Terminal Strip) D1) N/O terminal D2) N/C terminal D3) Common Terminal 7 Segment LED Display: will indicate Battery Voltage, Solar voltage, wattage generation from solar panel parameters Selector Switch: To select solar zone voltage On position: 11.5 V Range will be selected Off Position: 12.2 V Range will be selected