Similar documents

Section 4. Axial Fans - Section 4

Section 4 e c tio - P lat F a n s

ExpressBuild STANDARD FAN RANGE

JM Aerofoil Multi-Stage 50 Hz

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT


Wide performance ranges are obtained by using three impeller designs to suit all types of applications.

DATASHEET 63JMP/20/4/3/32

CASED & PLATE AXIAL - ACCESSORIES

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

JM Aerofoil Bifurcated Fans

BIFLOW SB CON Product Brochure

CASED AXIAL BIFURCATED SERIES 33

MAJAX-2 GENERAL SPECIFICATION

Hison Axial Flow Fans

Hison Axial Flow Fans

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Sabre Plate Mounted Sickle Fans (VSP)

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Bifurcated Case Axial Fans (BIFA)

BIFURCATED AXIAL FANS

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

JM Aerofoil Bifurcated 50Hz

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Sabre Sickle Fan Assisted Roof Cowls (VSR)

TURBOFLOW TF Contra Rotating Axial Flow Fan

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

Vent-Axia Sabre Sickle Roof Fans (VSR)

Square Mixed Flow Fans (MFQ)

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Axial fans. What s more, non-stock models are normally available within two weeks.

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Max. airflow m 3 /s Diam. min. Diam. max

ROOFMASTER STEF-HT ROOF FAN

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ROOFMASTER STEF-HT ROOF FAN

TGT Series Adjustable Pitch Fans

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

ROOFMASTER STEF-ATEX ROOF FAN

TGT Series Adjustable Pitch Fans

Mixed Flow Roof Fans (RMH)

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS

Mixed Flow Roof Fans (RMH)

LC/SC. Long & Short Cased Axial Fans

Short casing. Long casing (L version) Commercial premises

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

REVOLUTION SLCX Product Brochure

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Acoustic Twin Fans (ATQ)

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CYLINDRICAL CASED AXIAL FLOW FANS

ifan Copford Box Range

Performance. Sound Levels. Impellers. Motors. Accessories

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Plate mounted axial flow fans HXBR / HXTR Series

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

ACOUSTIC CABINET FANS CVAB / CVAT Series

WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS.

WINDER. Impellers with higher efficiency and less sound level

AXIAL FANS Catalogue CN0050C01 May 2008

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Kitchen exhaust fan GLEB

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Multifunctional 400ºC/2h and 300ºC/2h roof fans

ROOFMASTER STEF ROOF FAN

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

Size and Configurations

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

AXUS HIGH TEMPERATURE AXIAL FANS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

ROOF FAN ROOFMASTER STEC

ACOUSTIC CABINET FANS CVB / CVT Series

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Twin City Fan & Blower

NEW Slimpak EC Box Fan (SLPT EC)

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

SQUIF HIGH TEMPERATURE FANS

DIRECT-AIR ILB / ILT Series Rectangular duct fans

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

CGT Series Adjustable Pitch Fans

CTVK Supply air diffuser

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

AXIAL FANS & VANEAXIAL FANS

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

Transcription:

400mm - 630mm diameter Volume flow up to 7.2m 3 /s ASED 42 Static pressures up to 1000 Pa High energy efficiency All casings are hot dipped galvanised Low installed noise levels protection IP55 Overheat protection fitted as standard Inverter controllable on 3φ controllable on 1φ and 3φ MaXfan/MaXfan Plus Sizes 400mm-630mm MaXfan and 630mm MaXfan Plus Fan Performance All fans are tested to the latest inter nationally recognised standard IS05801 1997, installation category D for aerodynamic performance and BS848 Part 2 (1985) for acoustic performance. Impellers A unique high efficiency aerofoil section blade with a purposely smoothed hub and clamp plate for adjustable pitch angle availability. The Fläkt Woods impellers are all high pressure die cast to off er thin aerofoil sections for low generation of noise. Every cast aluminium component is X-r ay examined using Real Time Radiography prior to assembly. s All motors are totally enclosed air stream r ated class F insulation. onstructed from aluminium as standard with special T slot or pad mounted fixings. s are suitable for speed control. for horizontal through to vertical shaft operation. Supplied IP55, with removable drain plugs. Sealed for life bearings lubricated with wide temperature range grease. s are fitted with thermostat overheat protection as standard. Three phase motors are suitable for inverter speed control down to 20% of full speed. Electrical Supply 220-240V / 50Hz / 1 φ 380-420V / 50Hz / 3 φ Temperature Range -40 to 50 as standard. (All motors are not suitable for starting at temperatures lower than - 20.) Fans that include BT or T motors can be continuously operated at temperatures up to 70. When these fans are operating in excess of 50 they should be run at full speed only. Other fans can be operated up to 70 with appropr iate deration of motors. asings MaXfans are available fully cased, complete with an e xternally mounted pre-wired electrical terminal box. asings are spun from sheet steel with integral pre-drilled and radiused inlet flanges. The galvanised finish gives a high resistance to corrosion and is ideal for external as well as internal use. Accessories Silencers, Mounting feet, Vibration isolators, flanges, connectors, Air operated non return dampers, Guards, Bell mouth inlets. For a full range please see pages 56-59. Application Guide

Performance Data MaXfan Sound pressure levels quoted are average dba at 3m distance over a sphere, based on form B running under free field conditions, and are presented for comparative purposes only. ylindrical silencers are available as standard. Bifurcated fans are not suitable for speed regulation. Bold text denotes Super Expr ess, next day delivery available if ordered by 4pm. Electrical Data 220-240V/50Hz/1φ m 3 /s at Pa (Static) rev/min Rating (kw) Full Load urrent (at 230 V) Starting urrent (at 230V) Wiring Diagram Ref ontroller Sound Level dba 100 200 300 400 500 600 40 MaXfan 1410 BT9 EQ411453 0.64 4.4 10 D1705 ME1.6 67 1.54 1.32 45 MaXfan 1410 T5 EQ461467 0.78 5.8 11.2 D1705 ME1.6 65 1.80 1.56 1.27 50 MaXfan 1380 T9 EQ511467 1.94 13.4 27 D1705 ME1.12 75 2.91 2.67 2.40 2.09 56 MaXfan 1380 T9 EQ571460 1.94 13.4 27 D1705 ME1.12 75 3.29 3.03 2.77 2.36 63 Maxfan 1380 T9 EQ641406 1.94 13.4 27 D1705 ME1.12 78 3.62 3.34 2.98 2.54 2.02 1.08 Wiring diagrams can be found on page 47. The fan noise levels shown are for the specified operating point. When an electronic controller is incorporated, a magnetic not e (enhanced motor noise) can occur - par ticularly if the fan is operating at speeds well below maximum. For noise sensitive applications FWL recommend using an auto transformer speed controller. ASED 43

ASED 44 Dimensions A B D H L M N P S T W Weight MaXfan 40 MaXfan BT9 400 480 680 279 450 350 400 10 250 8 12 590 38 45 MaXfan T5 450 530 620 306 500 400 450 10 280 8 12 530 43 50 MaXfan T9 500 594 710 338 560 450 500 10 315 12 12 620 57 56 MaXfan T9 560 654 680 368 620 510 560 10 355 12 12 590 61 63 MaXfan T9 630 724 710 403 690 580 630 10 400 12 12 624 71 JM ylindrical Silencers Bore Dia. mm (D) Length Acoustic Performance (db) Octave Band Mid Frequency Hz 63 125 250 500 1K 2K 4K 8K 400 1D 2 3 5 10 13 11 9 8 450 1D 2 3 6 12 13 11 10 6 500 1D 2 3 6 13 14 10 10 5 560 1D 2 4 7 14 14 19 10 7 630 1D 2 5 7 15 13 8 9 8 All dimensions shown in mm. for fan OA s B J Weight B B 400 SB241401 500 400 M10 15 18 450 SB251401 600 450 M10 20 24 500 SB271401 650 500 M10 25 29 560 SB281401 710 560 M10 30 35 630 SB301401 780 630 M10 35 42 * For type silencer change prefix from SB to S The above silencers give the following approximate dba reductions: B 1 diameter length 7 to 10 dba For full acoustic details and resistance to air flow for type see publication SPO1. s & onnector Rubber in Shear V ibration Isolators Mounting Feet ontroller for fan OA s onnector Weight onnection 400 DA074913 AS040400 110 1.5 4.5 450 DA501353 AS040450 110 1.7 5 500 DA074914 AS040500 110 2 5.5 560 DA501355 AS040560 110 2.3 6.8 630 DA074915 AS040630 160 3 7.5 Load range per mounting A B E F H J K L 19.100.yellow 5-28 DA267336 80 45 5 32 57 M8 41 12 9 19.100.Blue 950 DA267337 80 45 5 32 57 M8 41 12 9 G L M N P T V W 400 DA408201 225 350 400 10 250 12 20 60 450 DA408202 255 400 450 10 280 12 20 60 500 DA408203 290 450 500 10 315 12 25 65 560 DA408204 330 510 560 10 355 12 25 65 630 DA243495 375 580 630 10 400 14 25 65 A B D ME1.3 DA410290 148 87 62 47 ME1.6 DA410291 148 87 62 47 Note: onnection weight includes two s.

Performance Data MaXfan Plus Sound pressure levels quoted are average dba at 3m distance over a sphere, based on form B running under free field conditions, and are presented for comparative purposes only. ylindrical silencers are available as standard. Bifurcated fans are not suitable for speed regulation. Bold text denotes Super Expr ess, next day delivery available if ordered by 4pm. 380-420V/50Hz/3φ m 3 /s at Pa (Static) rev/min Rating (kw) Full Load urrent (at 400V) Starting urrent (at 400V) Wiring Diagram Ref ontroller Sound Level dba 0 200 400 600 800 1000 63 MaXfan Plus 1420 112 EQ661405 8.8 18.6 110 D1343 FWD7 79 7.21 6.88 6.51 6.03 5.52 4.82 Wiring diagrams can be found on page 47. The fan noise levels shown are for the specified operating point. When an electronic controller is incorporated, a magnetic not e (enhanced motor noise) can occur - par ticularly if the fan is operating at speeds well below maximum. For noise sensitive applications FWL recommend using an auto transformer speed controller. ASED 45

ASED 46 Dimensions A B D E H L M N P S T V W 63 MaXfan Plus 112 630 724 1040 403 3 690 580 630 10 400 12 12 50 954 155 Weight MaXfan Plus JM ylindrical Silencers Bore Dia. mm (D) Length Acoustic Performance (db) Octave Band Mid Fr equency Hz 63 125 250 500 1K 2K 4K 8K 630 1D 2 5 7 15 13 8 9 8 for fan OA s B B J Weight B 630 SB301401 780 630 M10 35 42 * For type silencer change prefix from SB to S The above silencers give the following approximate dba reductions: B 1 diameter length 7 to 10 dba For full acoustic details and resistance to air flow for type see publication SPO1. Mounting Feet G L M N P T V W 630 DA243495 375 580 630 10 400 14 25 65 s & onnector for fan OA s onnector Weight onnection 630 DA074915 AS040630 160 3 7.5 Rubber in Shear V ibration Isolators Max Load per mounting A B E F H J K L 19.100.Blue 50 DA267337 80 45 5 32 57 M8 41 12 9 Inverter A B Weight Note: onnection weight includes two s. FWD7 416522 480 242 260 23 All dimensions shown in mm.

Wiring Diagrams D1705 Fan MaXfan/MaXfan Plus Fan + Electronic ontroller D1343 Fan ASED 47