Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Similar documents
Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Application Mini Contactors for Motors and Resistive Loads

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Application Mini Contactors for Motors and Resistive Loads

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Miniature circuit-breaker (MCB) SH200M Series

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

max pole for t=15 ms

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

COMBINATION CIRCUIT BREAKERS RCBO

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

NB1 Miniature Circuit Breaker

MS25, MST25, MS20, MST20

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

and other modular devices for low voltage installation

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Control Circuit Protection

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077


Phase + Neutral, neutral on left side

MS General Information Extended Product Type: MS

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

BETA Switching Switches and Light Indicators

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Phase + Neutral, neutral on right side

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Jtec 10kA Miniature Circuit Breaker

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

MINIATURE CIRCUIT BREAKER

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

D509E. Manual Motor - Starters

DX³ 4-pole RCBO 6000 A/10 ka

Motorized switch-disconnectors OTM 40 to 125 Amperes

Electronic circuit breaker EBU10-T

LINOCUR Size D02 63A 230VAC/440VAC

Modular contactors and relays

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Protection components

Electronic overload relays EF205 and EF370

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A

ABB STOTZ-KONTAKT GmbH

Selective main circuit breakers S 750 series Technical Data

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

Miniature Circuit Breaker

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Miniature Circuit-Breakers (MCBs)

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Series L9 UL489 Miniature Circuit Breakers

Electronic overload relay EF65, EF96 and EF146

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

DX³ RCBO 6000A Phase + Neutral, neutral on left

1 Phase electronic contactor (SC 1)

Manual motor starters Overview and benefits

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

FAQ s. Are you AS/NZS Ready?

MULTIVERT 1000A Main Incomer, 690VAC

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Fuse switch-disconnectors

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Miniature Circuit-Breakers (MCBs)

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

DX³ RCCBs - ID 4P up to 100 A

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Short-circuit current limiter S800-SCL-SR

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Transcription:

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC Partno. FAZ-C6/1N CatalogNo. 278668 EatonCatalogNo. FAZ-C6/1N EL-Nummer 1695203 Similar to illustration Deliveryprogram Basic function Miniature circuit-breakers Number of poles 1 pole+n Tripping characteristic C Application Switchgear for industrial and advanced commercial applications Rated current I n A 6 Rated switching capacity acc. to IEC/EN 60947-2 ka 15 Product range FAZ Technicaldata Electrical Standards IEC/EN 60947-2 IEC/EN 60898 Rated operational voltage U e V U e V AC 240/415 V DC 60 (per pole) Rated switching capacity acc. to IEC/EN 60947-2 ka 15 Operational switching capacity ka 7.5 Characteristic B, C, D Max. back-up fuse A gl/gg 125 Selectivity Class 3 Lifespan Operations > 10000 Direction of incoming supply as required Mechanical Standard front dimension mm 45 Enclosure height mm 80 Terminal protection Finger and back-of-hand proof to BGV A2 Mounting width per pole mm 17.5 Mounting IEC/EN 60715 top-hat rail Degree of Protection IP20, IP40 (when fitted) Terminals top and bottom Twin-purpose terminals Terminal capacities mm 2 mm 2 1 x 25 mm 2 2 x 10 Thickness of busbar material mm 0.8 2 Mounting position As required DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 6 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 1.6 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -40 Operating ambient temperature max. C 75 09/07/2017 278668 - HPL-ED2017 V36.0 EN 1 / 8

linear, per +1 C, results in a 0.5% reduction of current carrying capacity IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042) Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss8.1-27-14-19-01 [AAB905011]) Release characteristic C Number of poles (total) 2 Number of protected poles 2 Nominal rated current A 6 Nominal rated voltage V 230 Rated short-circuit breaking capacity Icn EN 60898 at 230 V ka 10 Rated short-circuit breaking capacity Icn EN 60898 at 400 V ka 10 Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V ka 15 Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V ka 15 Voltage type AC Current limiting class 3 Frequency Hz 50-60 Concurrently switching N-neutral Yes Suitable for flush-mounted installation No Over voltage category 3 Pollution degree 2 Width in number of modular spacings 2 Built-in depth mm 70.5 Additional equipment possible Yes Degree of protection (IP) IP20 09/07/2017 278668 - HPL-ED2017 V36.0 EN 2 / 8

Characteristics Let-through energy I 2 t According to IEC/EN 60898 09/07/2017 278668 - HPL-ED2017 V36.0 EN 3 / 8

09/07/2017 278668 - HPL-ED2017 V36.0 EN 4 / 8

09/07/2017 278668 - HPL-ED2017 V36.0 EN 5 / 8

09/07/2017 278668 - HPL-ED2017 V36.0 EN 6 / 8

Tripping characteristic at 30 C: B, C, D to IEC/EN 60898 09/07/2017 278668 - HPL-ED2017 V36.0 EN 7 / 8

Dimensions Additionalproductinformation(links) AWA1220-1755Circiut-breaker AWA1220-1755 Circiut-breaker ftp://ftp.moeller.net/documentation/awa_instructions/17550701.pdf 09/07/2017 Eaton Industries GmbH http://www.eaton.eu 09/2017 by Eaton Industries GmbH 278668 - HPL-ED2017 V36.0 EN 8 / 8