GTS-L4 5 / 10 / 15 TECHNICAL DATA

Similar documents
GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

GTS 15/25/40/50/60/75/90/120A

GQ 15 / 25 / 50 / 90 A SINGLE PHASE SOLID STATE RELAYS

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

GTZ 25 / 40 / 55. THREE-PHASE SOLID STATE RELAYS WITH LOGIC CONTROL Vdc / Vac PROFILE. TECHNICAL DATA General features

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

GIB TECHNICAL DATA MECHANICAL DIMENSIONS SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) ENTRY LEVEL tilt sensor with MEMS technology.

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

User Manual Rittal PMC UPS 6kVA

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

The High Power Stack Horizon

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

RVS-AX Instruction Manual

Scheda prodotto Relè Series B

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Power Supplies PSS Series

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

Triple Output Power Supply

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

POWER SUPPLY UNIT FOR 3 KW MAGNETRON TECHNICAL NOTE

1SVC F SVC F 0607 R100.20/30 R100.45

XLR Energy Storage Module

Solid State Relays contactor with Integrated Fuse Type RGC1F

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Model Number Structure

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

ACCESSORIES FOR GEFLEX SYSTEM

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

SOLSTART Instruction Manual

General Description and Quick Selection Guide...E2. Series SAS Panel Mount Hockey Puck Relays...E4. Series SAR DIN-Rail Mount Relays...

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Series KTU7 UL489 Molded Case Circuit Breakers

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Model Number Structure

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

A6Z OPERATING MANUAL

Reduced Voltage Motor Starters

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

CD3000S-1PH Thyristor Unit Heater Break version

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

3 - Protection components Motor circuit-breakers

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

TECHNICAL DESCRIPTION

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

VALIADIS S.A. HELLENIC MOTORS

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Series KTU7 UL489 Molded Case Circuit Breakers

SINUS K 13. ACCESSORIES Braking resistors APPLICATION TABLES 78/160 INSTALLATION INSTRUCTIONS

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Multi-Mover Charger for model L25

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

SECTION DC POWER SUPPLY/BATTERY CHARGER

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

1 Phase electronic contactor (SC 1)

ADVANCED MODULAR POWER CONTROLLER

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Master & Slave SCRs. SCRs for 1 or 3 Phases Nominal Current Max Voltage Slave (Pulse Input) Master (Analog Input) 901-E included Series (SCR)

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

Switching DC Power Supply

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Microswitches M series

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

EM DC Multi-Function DC Energy Meter

Motor Controllers Soft Starting/Soft Stopping Types RSC 4.../RSO 12.., RSC 60.../RSO 16..

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

SMT-BM 20 A BMM 05 F BMM 05 AF

3000W HF/PFC Battery Charger

Dimensions WxHxD [mm] Weight [kg]

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Model 1672, 1673 Triple Output Power Supply

CD3000S-1PH Thyristor Unit Analog Input version

POWER SUPPLY UNIT FOR 2 KW MAGNETRON TECHNICAL NOTE

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Transcription:

GTS-L4 5 / 0 / 5 POWER SOLID STATE RELAYS WITH FOUR INDEPENDENT SOLID STATE RELAYS Main applications Extrusion lines and injection presses for plastics Hot channels Thermoforming machines Packing and packaging machines Main features 4 independent channels Logic signal input control Switching at voltage zero crossing. LED display of logic control state Overvoltage protection Faston connections Provision for DIN bar attachment, panel attachment and base attachment PROFILE GTS-L4 power solid state relays have four miniaturized solid state relays mounted on a single aluminum heatsink and control four independent resistive loads. The control inputs are four independent logic signals with zero crossing switching. Various models are available for currents up to 5A and voltages up to 440 VAC. All models guarantee operation at rated currents with continuous power supply at 40 C. Small channel size and 4-way modularity make the GTS-L4 ideal for applications with many temperature-controlled zones. GTS-L4 models are the perfect addition to Gefran s GFXTERMO multichannel controllers for single-phase and bi-phase applications, and can be replaced individually on each channel. Their high performance makes them suitable for applications demanding very short switching times, offering millions of operations without component wear. Connections are Faston-type; mounting is on DIN rail or panel. TECHNICAL DATA General features Category of use: AC Nominal voltage - 30Vac (max. range 4...53Vac) - 440Vac (max. range 4..484Vac) Nominal frequency: 50/60Hz Non-repetitive voltage: 500Vp for model with 30 VAC rated voltagec 800Vp for model with 440 VAC rated voltage Zero switching voltage: < 0V Activation time: =/ cycle Deactivation time: =/ cycle Voltage drop at nominal current : = <.4Vrms Power factor = Maximum dissipated power: Pd = 4xIL x,5 [W] With IL = current of each load [A] Control inputs Max. input: 5mA @3V Max. reverse voltage: 36Vdc GTS-L4 5/0/5 Control voltage: 3...3Vdc Activation voltage: >.55Vdc Deactivation voltage: <Vdc OUTPUTS GTS L4 5 Nominal current: 5A@40 C in continuous service for every channel Non-repetitive overcurrent t=0ms: 80A I t for blowout: 45A s GTS L4 0 Nominal current: 0 A@40 C in continuous service for every channel Non-repetitive overcurrent t=0 ms: 0A I t for blowout: 00A s GTS L4 5 Nominal current: 5 A@40 C in continuous service for every channel Non-repetitive overcurrent t=0 ms:60a I t for blowout: 80A s Isolation Rated isolation voltage input/output: 500VAC rms Ambient conditions: Working temperature: 0 to 80 C (see the dissipation curves)

Max. relative humidity: 50% to 40 C Max. installation altitude: 000m asl Pollution level: 3 Storage temperature: -0..+85 C Internal use Installation notes Models with external heatsink must be grounded. Use the high-speed fuse indicated in the catalog according to the connection example. Applications with power solid state relays require an automatic safety cutout to disconnect the load power line. For maximum reliability, install the device correctly in the panel to have sufficient heat exchange between the heatsink and the air under conditions of normal convection. FACEPLATE DESCRIPTION LED control Mount it vertically (max. 0 inclination from the vertical axis) Vertical distance between a device and the panel walls >00mm Horizontal distance between a device and the panel walls: at least 0mm Vertical distance between devices: at least 300mm Horizontal distance between devices: at least 0 mm. Make sure that the wire raceways do not reduce such distances: if they do, install the groups cantilevered to the panel so that air can flow vertically over the heat sink without obstructions. Limits of use Dissipation of thermal power on the device with restraints on the ambient temperature of the installation.,: faston connection 3,4: Load faston connection 7: Control signal (+) 8: Control signal (-) 9: Ground faston Equipe the cabinet with an external air source or air-conditioning unit, to exhaust the dissipated heat power. Installation restraints (distances to be respected to grant dissipation with natural convection) transistor max. voltage and derivative limits, for which the solid state relay is equipped with inside safety devices (varistor). pleakage current < 4mA for GTS-L4. (max. value with rated voltage and junction temperature of 5 C). 9 WORKING TYPOLOGY Voltage logic output control V Control input ON OFF ON V = Load voltage t Power supplied = Installed power x TC / T

MOUNTING DIMENSIONS 60 33 6,58 8, 00 USE WITH PANEL MOUNTING (ACCESSORY) 7,5 8, 5,8 3 00 6 6 4 00 43,6 DISSIPATION CURVES Rated current curves based on room temperature. (understood as current running in all modules at 00% of conduction) I(A) 8 5 9 6 3 GTS - L4 5 / 0 / 5 4 0 5 0 5 40 80 T(C )

SAFETY AND PROTECTIONS - The heatsink must be grounded. - With currents higher than 8 Amps, you have to connect the relay to the line and to the load by connecting both (, ) and Load (3, 4) terminals in parallel, according to the connection diagrams. - The relay must be protected by an appropriate high-speed fuse suitable for the application with lt lower than that of the solid state relay. - With currents lower than 8 Amperes (if only one terminal and one Load terminal are used), it is important to realize that the other two fastons are potentially dangerous in case of accidental contact. Therefore, these must be appropriately protected by blocking access to the GTS-L4 or by using other insulated fastons to cover these contacts. CONNECTION EXAMPLES Phase Neutral Ground Fuse Load Load Fuse Fuse 3 Fuse 4 Load 3 Load 4 C 05 06 OUT OUT OUT3 OUT4 3 Load 4 3 Load 4 3 Load 4 3 Load 4 GND OUT OUT OUT3 OUT4 07 08 C9 09 C0 00 L+ L+ PE M M DI DI 0 0 03 04 I5+ I6- I6+ I7- I7+ I8- I8+ I- I+ IN I- I+ IN I3- I3+ IN3 I4- I4+ IN4 RN ER DI DI 0 0 03 04 TABLE OF TERMINAL AND LOAD CHARACTERISTICS CONTROL TERMINAL POWER TERMINAL GROUND TERMINAL Contact pre-insulated Max. sect ** Size area wire terminal conductor (WxD) tightening screw type torque 5A - Faston connector*,5mm 0A - Faston connector*,5mm 5A - Faston connector*,5mm Contact pre-insulated Max. sect ** area wire terminal wire (WxD) tightening screw type torque 6,4x9 Faston connector*,5mm 6,4x9 Faston connector*,5mm 6,4x9 Faston connector*,5mm Contact Max. section ** area conductor (WxD) tightening screw type torque 9x M5,5mm,3-,8 Nm 9xM5,5mm,3-,8 Nm 9xM5,5mm,3-,8 Nm (*) Female Faston 4,8 X 0,5 mm (**)Maximum sections indicated refer to unipolar copper leads isolated in PVC. Note: you have to use an eye terminal for the ground connection. (WxD) = width x depth ACCESSORIES A wide range of accessories is available, such as fuses and fuse holders, relay bases, panel attachments and DIN guide attachments, thermostats. To choose accessories, see the section "Solid state relays - Accessories.

ORDER CODE GTS-L4 / Model GTS-L4 Nominal current 5Aac 0Aac 5Aac 5 0 5 Nominal voltage 30Vac 30 440Vac 440 Please contact GEFRAN personnel for information on availability of codes. WARNINGS WARNING: this symbol indicates danger. Before installation, please read the following advices: follow the indications of the manual scrupulously when making the connections to the instrument. use a cable that is suitable for the ratings of voltage and current indicated in the technical specifications. if the instrument is used in applications where there is risk of injury to persons and damage to machines or materials, it is essential that it is used with an auxiliary alarm device. It is advisable to verify frequently that the alarm device is functional even during the normal operation of the equipment. The instrument must NOT be used in environments where there could be the presence of dangerous atmospheres (inflammable or explosive). During continuous operation, the heatsink may reach 00 C and remain at a high temperature due to thermal inertia even after the device is switched off. Therefore, DO NOT touch the heat sink or the electrical wires. do not operate on the power circuit untless the main supply is disconnected. DO NOT open the cover if device is ON! (use the holes in the cover for eventual re-calibration). Installation: connect the device to the ground using the proper ground terminal. the power supply wiring must be kept separate from that of inputs and outputs of the instrument; always check that the supply voltage corresponds to that indicated on the instrument cover. evitare la polvere, l umidità, i gas corrosivi, le fonti di calore. keep away from dust, humidity, corrosive gases and heat sources. The connection cable must be shorter than 3 meters if the current transformer is used. Maintenance: Check the correct operation of the cooling fans at regular intervals; clean the ventilation air filters of the installation at regular intervals. Repairs must be performed only by specialized or appropriately trained personnel. Cut off power to the device before accessing internal parts. Do not clean the box with solvents derived from hydrocarbons (trichloroethylene, gasoline, etc.). Using such solvents will compromise the mechanical reliability of the device. To clean external plastic parts, use a clean cloth wet with ethyl alcohol or water. Technical service : GEFRAN has a technical service department. Defects caused by use not conforming to the instructions are excluded from the warranty. GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice In conformity to ECC 004/08/CE and 006/95/CE with reference to standards: CEI-EN 6000-6- (immunity in industrial enviroment) EN 6000-6-4 (emissions in industrial environments)) EN 600- (safety requirements). GEFRAN spa via Sebina, 74-5050 Provaglio d Iseo (BS) Tel. 0309888 - fax 0309839063 - Internet: http://www.gefran.it DTS_GTS-L4_08_ENG