Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

Similar documents
barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

barmesapumps.com BGP-DS RPM Installation, Operation & Maintenance Manual Submersible Grinder Pumps

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE

ESE Series Cast Iron Sewage Pumps

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Ion Technologies ES45 Effluent Pump

barmesapumps.com 3BSE-SS 1.5, 2 & RPM Installation, Operation & Maintenance Manual Submersible Non-Clog Sewage Pumps

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

Portable Utillity Submersible Pump Model: UT17-1/6 Hp, 120 Volt, 60Hz, 1Ph

Installation Manual. Q Series Quadplex Grinder Systems. Contents

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

SH30 High Head Effluent Pump

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

PRE-PLUMBED SEWAGE SYSTEM

SUNC3000 / Item #40885

BARNES. INSTALLATION and OPERATION MANUAL. Submersible Sump / Effluent Pump

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

2460 / 2472 / Series Simplex Grinder Systems

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Series: PF8NC RPM, 60 Hz Submersible Non-Clog Pumps INSTALLATION, SERVICE & PARTS MANUAL

SUBMERSIBLE SUMP PUMPS

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Matala. VersiFlow Series. Instruction and Maintenance Manual

ON-SITE WASTEWATER PRODUCTS

Ion Technologies WC33 Submersible Sump Pump

AUTOMATIC SUBMERSIBLE UTILITY PUMP

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

SUBMERSIBLE SUMP PUMPS

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Series: PFU31 PFU51, PFU71 PFU102 PFU152 PFU202

barmesapumps.com 4BSE-DS 4.5, 7.5, 11.3, RPM Installation, Operation & Maintenance Manual Submersible Non-Clog Sewage Pumps

Sump / Effluent Pump

StormPro BA Series Sump Pump

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Pump Specifications 250 Series Submersible Sump / Effluent Pump

GeyserMax-Flow Series

XLE100/150 Series Explosion-proof Submersible Sewage Pumps

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Submersible Effluent Pump

GARDEN HOSE UTILITY PUMP

Submersible Sewage Ejector Pump

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

Installation Manual. Engineered Pump Systems (EPS) Common Components: Manual Contents:

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PACO INSTANT PUMPS

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

SHEF30 Submersible Sump/ Effluent Pump

SP40 Submersible Sewage Ejector Pump

Owner s Manual Drill and Light Weight Portable Utility Pumps

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Series: SP33.33 HP, 3450 RPM, 60 Hz..2 HP, 2850 RPM, 50 Hz.

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

barmesapumps.com CD SERIES RPM Installation, Operation & Maintenance Manual End-Suction Centrifugal Stainless Steel Pumps

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

barmesapumps.com BGP-DS 3, 5, 7.5, 3450 RPM Installation, Operation & Maintenance Manual Submersible Grinder Pumps

barmesapumps.com 2AHS 0.5 & RPM Installation, Operation & Maintenance Manual Submersible Dewatering Pumps

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

HALLMARK INDUSTRIES INC

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Installation & Operating Manual

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

StormPro BCV400 Sewage Ejector Pump

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

barmesapumps.com 2AHS 0.5, 1 & RPM Installation, Operation & Maintenance Manual Submersible Dewatering Pumps

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Transcription:

INSTALLATION MANUAL Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX 1/3 & 1/2 HP 3450 RPM 60 Hz Submersible Effluent/Sump Pumps ISP No: PFSump - 6/13

General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information could cause serious bodily injury, death and/or property damage. Each Power-Flo pump is individually factory tested to insure proper performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service. Risk of electric shock. To reduce risk of electric shock, always disconnect pump from power source before handling. Lock out power & tag. Installation must be in accordance with the National Electric Code and all applicable state and local codes. Installation and servicing is to be conducted by qualified personnel. These pumps are NOT to be installed in locations classified as hazardous in accordance with the National Electric Code, ANSI/NFPA 70. Keep clear of suction and discharge openings. Do not insert fingers in pump with power connected. Always wear eye protection when working on pumps. DO NOT use power cord to lift pump. Protect cable from cuts and punctures. Do not handle power cable with wet hands. Do not us these pumps in water over 104 F. Pumps build up heat and pressure during operation-allow time for pumps to cool before handling or servicing. This pump is NOT intended for use in swimming pools or any body of water with human contact. Pumps when used as a decorative water fountain pump MUST be used in circuit protected by a Ground Fault Interrupter. Installations in Decoritive Fountains or Water Features provided for visual enjoyment MUST be installed per ALL State and Local codes. ALL RETURNED PRODUCTS MUST BE CLEANED, SANITIZED, OR RECONTAMINATED PRIOR TO SHIPMENT, TO INSURE EMPLOYEES WILL NOT BE EXPOSED TO HEALTH HAZARDS IN HANDLING SAID MATERIAL. ALL APPLICABLE LAWS AND REGULATIONS SHALL APPLY. Model Number MFG Date AMPS PHASE 60 Hz HP VOLTAGE C US 877-24 PUMPS www.powerflopumps.com IMPORTANT! Prior to installation, record Model Number, MFG Date, and/or serial number, from pump name plate for future reference. 2 Power-Flo is a registered trademark of Power-Flo Technologies Inc. Other brand and product names are trademarks or registered trademarks of their respective holders. Alteration Rights Reserved. 3/08, 6/08, 7/08, 4/09, 4/10, 6/13

PF33 & PF50 Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, PF33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX 1/3 & 1/2HP, 3450 RPM, 60 Hz Submersible Sump Pumps DISCHARGE LIQUID TEMPERATURE MOTOR HOUSING/ VOLUTE STRAINER IMPELLER SHAFT O-RINGS HARDWARE SEAL - PF33/50 SEAL - PF33HT POWER CORD UPPER BEARING LOWER BEARING MOTOR SINGLE PHASE PAINT LEVEL CONTROL- PF33: PF33X & PF50X: PF33A: PF33AX & PF50AX: PF33AX-30: PF33X-30: PF33VF: PF33VFX & PF50VFX: MIMIMUN SUMP DIAMETER 1-1/2 NPT, Female, Vertical PF33/50-104 F Continuous Cast Iron, Class 30 PF33/50 - Thermoplastic Specifications 10 vane vortex, with pump out vanes on back side, Balanced. Material: Cast Iron Stainless Steel Buna-N 300 Series Stainless Steel Single Mechanical, Carbon/Ceramic/Buna-N Single Mechanical, Silicon Carbide/Buna-N 10 Ft., 20 Ft., or 30 Ft. cord with plug Single Row, Ball, Oil Lubricated Single, Row, Ball, Oil Lubricated Oil Filled, Class B insulation Permanent Split Capacitor (PSC), Includes Overload Protection in Motor Powder Coated - Industrial Grade (a) Manual, no float control & 10 ft long (b) Manual, no float control & 20 ft long (c) Wide angle, mechanical & 10 ft long (d) Wide angle, mechanical & 20 ft long (e) Wide Angle, mechanical & 30 Ft long (f) Manual, no float control & 30 Ft long (g) Vertical pvc float & 10 ft long power cord with plug (h) Vertical pvc float & 20 ft long power cord with plug (a) 12 diameter: PF33, PF33X, PF50X, PF33VF, PF33VFX & PF50VFX (b) 18 diameter: PF33A, PF33AX & PF50AX C US 3

PF33 & PF50 Dimensions PF33 & PF50 without float PF33VF & PF50VF vertical level control with piggy-back plug PF33A & PF50A with Wide angle float MODEL HP Hz Volts/ Ph RPM Full Load Amps Locked Rotor Amps NEMA Start Code Cord Type Cord Size Cord Length Automatic or Manual* Winding Resistance Main-Start PF33 1/3 60 115/1 3450 7.5 23 K SJTW 16/3 10 Ft MAN 2.9-28.8 PF33X 1/3 60 115/1 3450 7.5 23 K SJTW 16/3 20 Ft MAN 2.9-28.8 PF33X-30 1/3 60 115/1 3450 7.5 23 K SJTW 16/3 30 Ft MAN 2.9-28.8 PF33A 1/3 60 115/1 3450 7.5 23 K SJTW 16/3 10 Ft AUTO 2.9-28.8 PF33AX 1/3 60 115/1 3450 7.5 23 K SJTW 16/3 20 Ft AUTO 2.9-28.8 PF33VF 1/3 60 115/1 3450 7.5 23 K SJTW 16/3 10 Ft AUTO 2.9-28.8 PF33VFX 1/3 60 115/1 3450 7.5 23 K SJTW 16/3 20 Ft AUTO 2.9-28.8 PF33AX-30 1/3 60 115/1 3450 7.5 23 K SJTW 16/3 30 Ft AUTO 2.9-28.8 PF50X 1/2 60 115/1 3450 8.0 23 F SJTW 16/3 20 Ft MAN 2.9-28.8 PF50AX 1/2 60 115/1 3450 8.0 23 F SJTW 16/3 20 Ft AUTO 2.9-28.8 PF50VFX 1/2 60 115/1 3450 8.0 23 F SJTW 16/3 20 Ft AUTO 2.9-28.8 (*) Note: Manual models, as noted above, require a separate approved pump control device or panel for automatic operation. Be sure the electrical specifications of the control selected properly match the pump s electrical specifications. 4

Receiving Inspection Upon receiving the pump, it should be inspected for damage or shortages. If damage has occurred, file a claim immediately with the company that delivered the pump. If the manual is removed from the packaging, do not lose or misplace. Storage Any product that is stored for a period longer than six (6) months from the date of purchase should be bench tested prior to installation. A bench test consists of, checking the impeller to assure it is free turning and a run test to assure the motor (and switch if provided) operate properly. Do not pump out of liquid. Controls Manual models require a separate approved pump control device or panel for automatic operation. Be sure the electrical specification of the control selected properly match the electrical specifications of the pump. It is recommended that a sump pump system have an audio and visual alarm that signals a malfunction of the system to reduce the potential for property damage. Figure 1 Recommended Submergence Level Minimum Submergence Level 3.5 Bottom of Feet Submergence The pump should always be operated in the submerged condition. The minimum sump liquid level should never be less than above the pump s volute (See Figure 1). Liquid Level Controls Typical Discharge Pipe Mounted: Refer to Figure 2 below which shows a typical installation of a 1 phase 115 volt pump using a level control mounted to the discharge piping with a piggyback plug. The level control should have adequate clearance so it cannot hang up in it s swing and that the pump is completely submerged when the level control is in the Off mode. By adjusting the cord tether the control level can be changed. Typical Installation with Wide Angle Level Control Figure 2 Figure 3 Installation Automatic: Plug float cord into GFI outlet, then plug pump cord into float cord. Manual: Plug pump cord directly into GFI outlet. Level Control Basic Instructions: Plug the level control plug into the GFI receptacle, then plug the pump into the piggy-back plug (See Figure 3). One cycle of operation should be observed, so that any potential problems can be corrected. It is recommended that the level control float should be set to insure that the liquid in the sump never drops below the top of the motor housing or a minimum level of 6 inches above the basin floor. Installation These pumps are recommended for use in a sump or basin. The sump or basin shall be sealed and vented in accordance with local plumbing codes. This pump is designed to pump effluent or wastewater, nonexplosive and noncorrosive liquids and shall NOT be installed in locations classified as hazardous in accordance with the National Electrical Code (NEC) ANSI/NFPA 70 or Canadian Electric Code (CEC). The minimum sump depth should be at least 24. Check the dimensions for minimum sump diameter. These are minumum requirements. 5

Installation The pump should never be installed in a trench, ditch, or hole with a dirt bottom. The legs will sink into the dirt and the suction will become plugged. A. Excavation: Excavate the hole as small as possible, with minimum recommended 8 diametrical clearance around the tank. Never place basin directly in contact with rocks or other sharp objects. Place only fine, 1/8 to 3/4 pea gravel or 1/8 to 1/2 washed, crushed stone as bedding between the basin and the hole walls. Do not use sand or native soil as backfill. Properly compact underneath the basin to provide a solid level base that can support the weight of the filled basin. B. Inlet Connection & Initial Backfill: Only fine, 1/8 to 3/4 pea gravel or 1/8 to 1/2 washed, crushed stone should be used around the bottom of the basin to hold it in place. Do not use sand or native soil as backfill. Make the inlet connection as required for your basin. C. Final Backfill: Only fine 1/4 to 3/4 pea gravel or 1/8 to 1/2 washed crushed stone is recommended. Do not use sand or native soil as backfill. Discharge Piping Discharge piping should be as short as possible and sized no smaller than the pump discharge. Do not reduce the discharge pipe size below that which is provided on the pump. Both a check valve and a shut-off valve are recommended for each pump. The check valve is used to prevent backflow into the sump. The shut-off valve is used to manually stop system flow during pump servicing. Electrical Connections Power cable: The power cable mounted to the pump must not be modified in any way. This pump is provided with a 3 wire cord and 3 prong grounded plug that must be connected into a 3 wire grounded Ground Fault receptacle. DO NOT USE THE POWER CABLE TO LIFT PUMP. Do not use an extension cord. Always rely upon a Certified Electrician for installation. Overload Protection: Single Phase - The stator in-winding overload protector used is referred to as an inherent overheating protector and operates on the combined effect of temperature and current. This means that the overload protector will trip out and shut the pump off if the windings become too hot, or the load current passing through them becomes too high. IMPORTANT! - The overload will then automatically reset and start the pump up after the motor cools to a safe temperature. In the event of an overload, the source of this condition should be determined and corrected immediately. Pre-Operation 1. Check Voltage and Phase Compare the voltage and phase information stamped on the pump name plate. 2. Check Pump Rotation - Improper motor rotation can result in poor pump performance and can damage the motor and/or pump. Incorrect rotation for Single-Phase pumps is unlikely. If the rotation is incorrect contact factory. 3. Name Plate - Record the information from the pump name plate to drawing in front of manual for future reference. 4. Insulation Test - An insulation (megger) test should be performed on the motor. Before the pump is put into service. The resistance values (ohms) as well as the voltage (volts) and current (amps) should be recorded. 5. Pump-Down Test - Be sure pump has been properly wired, lowered into the basin, sump or lift station, check the system by filling with liquid and allowing the pump to operate through its pumping cycle. The time needed to empty the system, or pump-down time along with the volume of water, should be recorded. Replacement Parts are not availlable for this unit. See below for Float switch replacement. Replacement Vertical Float Switchs with Piggy-Back Plug Part No Cord Pump Length PF113647 10 Ft PF33VF PF512041 20 Ft PF33VFX, VF50VFX PF512041A 30 Ft PF33VFX-30, VF50VFX-30 Replacement Wide Angle Float Switchs with Piggy-Back Plug Part No Cord Length PF106929 10 Ft PF512040 20 Ft PF512040-30 30 Ft 6

Trouble Shooting Chart Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs. Symptom Possible Cause(s) Corrective Action Pump will not run Pump will not turn off Pump hums but doesn t run Pump delivers insufficient capacity Pump cycles too frequently or runs periodically when fixtures are not in use Pump shuts off and turns on independent of switch, (trips thermal overload protector). CAUTION! Pump may start unexpectedly. Disconnect power supply. Pump operates noisily or vibrates excessively 1. Poor electrical connection, blown fuse, tripped breaker or other interruption of power; improper power supply 2. Motor or switch inoperative (go to manual operation) 2a. Float movement restricted 2b. Switch will not activate pump or is defective 2c. Defective motor 3. Insufficient liquid level 2a. Float movement restricted 2b. Switch will not activate pump or is defective 4. Ecessive inflow or pump not properly sized for application 9. Pump may be air locked causing pump not to flow 14. H-O-A switch on panel is in HAND position 1. Incorrect low voltage 8. Impeller jammed or loose on shaft, or inlet plugged 1. Incorrect low voltage 4. Ecessive inflow or pump not properly sized for application 5. Discharge restricted 6. Check valve partially closed or installed backwards 7. Shut-off valve closed 8. Impeller jammed or loose on shaft, or inlet plugged 9. Pump may be air locked causing pump not to flow 10. Piping fixtures leaking or discharge before the nozzle 6. Check valve partially closed or installed backwards 11. Fixtures are leaking 15. Ground water entering basin 1. Incorrect low voltage 4. Ecessive inflow or pump not properly sized for application 8. Impeller jammed or loose on shaft, or inlet plugged 12. Excessive water temperature (internal protection only) 2c. Worn bearings, motor shaft bent 5. Debris in impeller cavity or broken impeller 10. Pumprunning backwards 13. Piping attachments to building structure too loose or rigid 1. Check all electrical connections for security. Have electrician measure current in motor leads, if current is within ± 20% of locked rotor Amps, impeller is probably locked. If current is 0, overload may be tripped. Remove power, allow pump to cool, then re-check current. 2a. Reposition pump or clean basin as required to provide adaquate clearance for float 2b. Disconnect level control. Set ohmmeter for a low rang, such as 100 ohms full scale and connect to level control leads. Actuate level control manually and check to see that ohmmeter shows zero ohms for closed switch and full scale for open switch. (Float Switch) 2c. Check winding insulation (Megger Test) and winding resistance. If check is outside of range, dry and re-check. If still defective, replace per service instructions. 3. Make sure liquid level is above the pump 4. Re-check all sizing calculations to determine proper pump size. 5. Check discharge line for restrictions, including ice if line passes through or into cold areas. 6. Remove and examine check valve for proper installation and freedom of operation 7. Open valve 8. Check impeller for freedom of operation, security and condition. Clean impeller cavity and inlet of any obstruction 9. Loosen union slightly to allow trapped air to escape. Verify that turn-off level of switch is set so that the suction is always flooded. Clean vent hole 10. Check rotation. If power supply is three phase, reverse any two of three power supply leads to ensure proper impeller rotation 11. Repair fixtures as required to eliminate leakage 12. Check pump temperature limits and fluid temperature 13. Replace portion of discharge pipe with flexible connector or tighten existing piping. 14. Turn to automatic position 15. Check for leaks around basin inlet and outlets NOTE: Power-Flo Pumps & Systems assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Power-Flo Pumps & Systems or its authorized service centers, automatically voids warranty. 7

2 YEAR WARRANTY Manufacturer warrants, to the purchaser and subsequent owner during the warranty period, new pump product to be free from defects in material and workmanship under normal use and service, when properly used and maintained, for a period of 2 years from date of sale. The date of sale shall be determined by a dated sales receipt noting the model and serial number of the pump. The dated sales receipt must accompany the returned pump if the date of the return is more than 2 years from the date of manufacturer. Product will be repaired, replaced or remanufactured at Manufacturer s option. No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product failure, repair or replacement. This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior approval of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has not been installed, operated or maintained in accordance with Manufacturer s installation instructions; that has been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels or feminine sanitary products, etc. in all pumping applications. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products. Contact Manufacturer at: 1-877-24PUMPS or www.powerflopumps.com, Attention: Customer Service Department, to obtain any needed repair or replacement of part(s) or additional information pertaining to our warranty. MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY. Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or con sequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 8