Submersible Sump / Effluent Pump

Similar documents
Submersible Sump / Effluent Pump

Submersible Effluent Pump

ME3F, ME3H Series. OWNER S MANUAL Submersible Sump / Effluent Pump 293 WRIGHT STREET, DELAVAN, WI PH:

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

Submersible Sewage Ejector Pump

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

Submersible Solids Handling Pumps

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

SP40 Submersible Sewage Ejector Pump

ESE Series Cast Iron Sewage Pumps

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

MWH50 - MW200 Series ME50 - ME150 Series Submersible Sump, Effluent & Sewage Pumps

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

Model E75STVT. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

SHEF30 Submersible Sump/ Effluent Pump

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

SUBMERSIBLE SEWAGE PUMPS

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

PRE-PLUMBED SEWAGE SYSTEM

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Submersible Solids Handling Pump

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

Submersible Grinder Pumps

OWNER S MANUAL Submersible Sewage Ejector Pumps

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

MODELS WGL20, WGL20H and WGL20F

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

ON-SITE WASTEWATER PRODUCTS

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Self-Priming Centrifugal Pumps

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Ion Technologies WC33 Submersible Sump Pump

IMPORTANT SAFETY INSTRUCTIONS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SWIMMING POOL DRAINER

OWNER S MANUAL Commercial Duty Pumps

MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

2460 / 2472 / Series Simplex Grinder Systems

SUBMERSIBLE SUMP PUMPS

Installation and Service Manual SK50 Submersible Sewage Ejector Pump

Sump / Effluent Pump

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

PUMP VAULT S.T.E.P. SYSTEM

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

Matala. VersiFlow Series. Instruction and Maintenance Manual

GARDEN HOSE UTILITY PUMP

StormPro BA Series Sump Pump

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Artesian2 Owners Manual

HALLMARK INDUSTRIES INC

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

Installation Operation Parts

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

GeyserMax-Flow Series

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Installation & Operating Manual

Transcription:

ME3F, ME3H Series 1101 Myers Parkway, Ashland, OH 44805 Phone: 1-419-289-6898 Fax: 1-419-289-6658 Web Site: http://www.myerspump.com Submersible Sump / Effluent Pump INSTALLATION, OPERATION, & PARTS MANUAL SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump. This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury! warns about hazards that will cause serious personal injury, death or major property damage if ignored. warns about hazards that can cause serious personal injury, death or major property damage if ignored. warns about hazards that will or can cause minor personal injury or property damage if ignored. The word NOTICE indicates special instructions which are important but not related to hazards. 1. Read these rules and instructions carefully. Failure to follow them could cause serious bodily injury and/or property damage. 2. Check your local codes before installing. You must comply with their rules. 3. Vent sewage or septic tank according to local codes. 4. Do not install pump in any location classified as hazardous by National Electrical Code, ANSI/NFPA 80-1984 or the Canadian Electrical Code. Hazardous voltage. Can shock, burn, or kill. During operation the pump is in water. To avoid fatal shocks, proceed as follows if pump needs servicing: Do not smoke or use devices that can generate sparks in a septic (gaseous) environment. 5A. Disconnect power to outlet box before unplugging pump. 5B. Take extreme care when changing fuses. Do not stand in water or put your finger in the fuse socket. 5C. Do not modify the cord and plug. When using the cord and plug, plug into a grounded outlet only. When wiring to a system control, connect the pump ground lead to the system ground. 6. Be sure that construction and access to septic sumps conform with all OSHA requirements. 7. Do not run the pump dry. Dry running can overheat the pump, (causing burns to anyone handling it) and will void the warranty. 8. The pump normally runs hot. To avoid burns when servicing pump, allow it to cool for 20 minutes after shutdown before handling it. 9. The pump is permanently lubricated. No oiling or greasing is required in normal operation. for overhaul, see instructions under Service. When used in effluent dosing or S.T.E.P. applications, the pump must be installed in a separate tank or compartment at the discharge side of the septic tank. NOTE: Never install the pump in the main tank where sludge collects. Do not use the pump for raw sewage. Myers has available for engineers (on request) complete computer software for designing Pressure Sewage Systems. This will give pipe sizes to use and gives the exact flow from any pump or group of pumps in the system when they are operating simultaneously. For IBM and IBM compatible computers. DESCRIPTION This submersible / effluent pump is designed for effluent dosing, Septic Tank Effluent Pumping (S.T.E.P.) and wastewater removal, sump drainage, dewatering and flood control. Units have built in thermal overload protection with automatic reset. The mechanical seal and sleeve bearings on the motor shaft are permanently lubricated. Stainless steel hardware and a heavy duty lift out handle allow for easy disassembly after extended use. NOTICE: This unit is not designed for applications involving salt water or brine! Use with salt water or brine will void warranty. SPECIFICATIONS Power Supply...See Table 1, Motor Specifications Maximum Liquid Temperature...120 F (49 C) Discharge Adapter...1-1/2" NPT Maximum Solids Handling...3/4" Motor Type...Shaded Pole RPM...1550 Motor Insulation...Class A Overload Protection...Internal with Automatic Reset Bearings...Double Sleeve Starting Switch Required...None Control Panel Required...None NOTE: This pump is not approved for, and should not be used in, swimming pools or fountains. 2008 23833A305 (5/19/08)

TABLE 1: MOTOR SPECIFICATIONS Pump Pump Winding Locked Branch Catalog Engineering Pump Volts/ Cord Resistance Max. Rotor Circuit Number Number Type HP Hz/Ph Length In Ohms Amps. Amps Req d (Amps) ME3H-11 26228D000 Manual ME3F-11 26229D000 Manual ME3H-11P 26228D010 Auto ME3F-11P 26229D010 Auto ME3H-21 26228D001 Manual ME3F-21 26229D001 Manual ME3H-21P 26228D011 Auto ME3F-21P 26229D011 Auto 1/3 115/60/1 20 1.2 12.0 16.0 15 1/3 230/60/1 20 4.3 6.0 8.2 15 PERFORMANCE Total Head in Feet 40 35 30 25 20 15 10 5 0 0 Liters per Minute 0 50 100 150 200 250 ME3H INSTALLATION ME3F 10 20 30 40 50 60 70 Gallons per Minute Total Head in Meters Hazardous voltage. Can shock, burn or kill. Do not lift pump by the power cord. See Cord Lift Warning below. NOTICE: Install the pump on a hard, level surface (cement, asphalt, etc.). Never place the pump directly on earth, clay or gravel surfaces. Install the pump in a sump basin with a minimum diameter of 18" (46cm). 12 10 8 6 4 2 0 Piping Piping must not be smaller than pump discharge. The pump is designed to operate partially or completely submerged in effluent liquids and pump semi-solid fluids up to 3/4" (51mm) in diameter. When installed in an effluent system, the pipe must be capable of handling semi-solids of at least 3/4" (19mm) in diameter. The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid. To meet minimum flow requirements (2 feet per second in the discharge line), size the pipe as follows: A Pipe Size Of: Will Handle a Flow Rate Of: 1-1/2" (38mm) 12 GPM 2" (51mm) 21 GPM 2-1/2" (64mm) 30 GPM 3" (76mm) 48 GPM In an effluent system use a 1-1/2" (38mm) check valve in pump discharge to prevent backflow of liquid into sump basin. The check valve should be a free flow valve that will easily pass solids. Be sure check valve installation complies with local codes. Be sure that the float switch hangs freely. It should not be able to come in contact with the sides or bottom of the sump pit. Make sure the sump pit is free of any debris that could obstruct the intake volute or switch. Use plumbing materials that are approved by local building codes when connecting pipes between pump and sewer outlet. NOTICE: For critical indoor installations where additional high water protection is desired, install an audible alarm system in the sump pit. For outdoor installations, confer with your distributor. Connect the power cord to a 3-prong grounded AC receptacle. WARNING Risk of electrical shock. Can burn or kill. Do not lift pump by power cord. CORD LIFT WARNING 1. Attempting to lift or support pump by power cord can damage cord and cord connections. 2. Cord may pull apart, exposing bare wires with possibility of fire or electrical shock. 3. Lifting or supporting pump by power cord will void warranty. 4. Use lifting ring or handle on top of pump for all lifting/lowering of pump. Disconnect power to pump before doing any work on pump or attempting to remove pump from sump. 2

Hazardous voltage. Can shock, burn or kill. DO NOT remove the grounding pin from the power cord. Avoid using extension cords or 2-prong adapter plugs. Insert the piggyback plug that comes from the float switch directly into the power receptacle. Insert the pump power cord directly into the back of the switch s piggyback plug/receptacle. Test the pump installation by filling the sump basin with enough water to activate the pump and repeat this cycle until satisfied with pump operation. NOTICE: For best performance of check valve when handling solids, do not install it with the discharge more than 45 above the horizontal. Do not install the check valve in a vertical position as solids may settle in the valve and prevent it from opening on startup. Drill a 1/8" (3mm) hole in the discharge pipe below the check valve to prevent airlocking the pump. Electrical Hazardous voltage. Can shock, burn, or kill. When installing, operating, or servicing this pump, follow the safety instructions listed below. 1. DO NOT splice the electrical power cord. 2. DO NOT allow the plug on the end of the electrical cord to be submerged. 3. DO NOT use extension cords. They are a fire hazard and can reduce voltage sufficiently to prevent pumping and/or damage motor. 4. DO NOT handle or service the pump while it is connected to the power supply. 5. DO NOT remove the grounding prong from the plug or modify the plug. To protect against electrical shock, the power cord is a three-wire conductor and includes a 3-prong grounded plug. Plug the pump into a 3-wire, grounded, grounding-type receptacle. Connect the pump according to the NEC or CEC and local codes. Automatic models have a 20' mechanical (mercury free), piggy-back float switch tethered directly to the pump. The switch can also be mounted on the discharge pipe, with a minimum 4" tether length. The switch must float free from the pump and the basin wall. Tape or cable-tie the cord to the discharge pipe every 12". Plug the switch into a properly grounded, grounding-type receptacle of the correct voltage. The receptacle must be installed according to all applicable codes. On all duplex units or simplex units with additional options such as a high water alarm, cut off the power cord plug and wire the pump into a control panel (or sealed junction box if it is installed in a wet sump or basin). The AWS-1 control also acts as a sealed junction box for connecting the power cord to the pump cord. Connect or wire pump to its own individual branch circuit with no other outlets or equipment in the circuit. Size fuses or circuit breakers according to Table 1, Motor Specifications. Risk of electrical shock and fire. Can burn, kill or cause property damage. Be sure that power supply information (Voltage/ Hertz/Phase) on pump motor nameplate matches incoming power supply exactly. Install pump according to all electrical codes that apply. OPERATION Risk of fire or explosion. Can cause severe personal injury, property damage or death. Do not use in explosive atmospheres. Pump water only with this pump. NOTICE: Do not allow the pump to run in a dry sump. It will void the warranty and may damage the pump. An automatic overload protector in the motor will protect the motor from burning out due to overheating/overloading. When the motor cools down, the overload protector will automatically reset and start the motor. If the overload trips frequently, check for the cause. It could be a stuck impeller, wrong/low voltage, or an electrical failure in the motor. If an electrical failure in the motor is suspected, have it serviced by a competent repairman. The pump is permanently lubricated. No oiling or greasing is required. Cycle the pump at least once every month to be sure that the system is working satisfactorily. NOTE: Any of the following will void the pump warranty: 1. Submerging, plugging, damaging or taping shut a vented cord. 2. Pumping materials other than those the pump was designed to pump or continuously pumping water hotter than 120 F (49 C). 3. Cutting or splicing a power cord or switch cord. 4. Removing the cord tag from the cord. SERVICE General Hazardous voltage and risk of cord damage. Can shock, burn, or kill. Before removing the pump from the basin for service, always disconnect electrical power to the pump and the control switch. Do not lift the pump by the power cord. See the Cord Lift Warning, Page 2. Disinfect the Pump Place the pump in an area where it can be cleaned thoroughly. Remove all scale and deposits on the pump. Submerge the complete pump in a disinfectant solution (chlorox or chlorine bleach) for at least one hour before disassembling the pump. The pump motor housing contains a special lubricating oil which should be kept clean and free of water at all times. NOTICE: Whenever the motor housing is being removed for service, remove oil and replace it with new oil at reassembly. Use only oil listed in parts list in this manual. When filling with new oil, DO NOT overfill. Be sure that the oil level is 3/4" below the top of the cover. Toxic gas hazard in septic tank. Never enter the pump chamber after effluent has been in the basin. Sewage water can give off methane, hydrogen sulfide, or other gases which are highly poisonous. For this reason Myers recommends installing effluent pumps with a quick removal system either a union with a Cam-lok coupling if the pipe is within reach from the top of the tank, or a rail system type quick disconnect on deeper systems. See Figures 4, 5, and 6, Pages 6, 7, and 8 for typical installations. 3

8-13/16 8-13/16 5-1/4 11-1/8 10-21/64 4-29/32 10-45/64 6-33/64 12-33/64 11-1/4 12-29/32 2-1/16 3-7/16 4-13/16 7-1/16 Figure 1: ME3H Dimensions Construct the dosing tank or pumping chamber of corrosion resistant materials and design it to withstand all anticipated internal and external loads. The tank must not allow infiltration or exfiltration, and must have anti-buoyancy provisions. Include access holes or covers accessible on the surface and of adequate size to allow installation and maintenance of the system. Make access covers lockable or heavy enough to prevent easy access by unauthorized personnel. Calculate the pumping chamber holding capacity to allow for emergencies. The discharge pipe must be at least 1-1/2" diameter (pump discharge size or larger). See Piping, Page 2, for minimum flow requirements. Install a full flow gate or ball valve as a shutoff valve in the discharge, to prevent backflow in case the pump must be removed for service. A Pressure Sewage System must also have a check valve installed. In other systems, if conditions allow, a check valve will prevent backflow and reduce wear and tear on the system. Install a high-water alarm system on a separate circuit from the pump circuit. The alarm should be testable for proper operation. MAINTENANCE Risk of dangerous or fatal electrical shock. Before working on pump or switch, always turn off the circuit breaker or fuse and unplug the switch cord and power cord. Automatic Float Switch Replacement Risk of contamination. Wear rubber gloves when working on switch. Dispose of old switch according to ordinances. 1. DIsconnect the power at the circuit breaker or fuse box and unplug the piggy-back float switch cord from the receptacle. Figure 2: ME3F Dimensions 2. Unplug the pump power cord from the back of the piggyback float switch plug. 3. If you cannot reach the switch tether point, remove the pump from the sump. 4. Disconnect the switch from its tether point and remove it from the discharge piping. 5. Attach the new switch to the pump or the discharge piping. Don t change the tether length or the attachment point. 6. Attach the power and switch cords to the discharge piping with cable ties or electrician s tape. 7. Plug the switch into the receptacle. 8. Plug the pump s power cord into the back of the piggyback switch plug. 9. Replace the pump in the basin. 10. Turn on the power to the receptacle. 11. Fill the basin and test operation through one complete operational cycle. NOTE: Failure to make this operational check can lead to flooding. ME3F / ME3H Seal Change 2 Hazardous voltage. Can shock, burn, or cause death. Before removing pump from basin for service, always disconnect electrical power to pump and control switch and unplug the pump and switch. Submerge complete pump in a disinfectant solution (chlorox or chlorine) for at least one hour before disassembling pump. The pump motor contains a special lubricating oil which should be kept clean and free of water at all times. 4

1. Remove the oil fill plug located on top of the motor housing and drain the oil in the housing. NOTE: Dispose of the oil according to ordinance. Do not reuse the oil since it may contain water from seal failure. 2. ME3F (See Below for ME3H): Remove three cap screws (Ref. No. 14B, Page 9; also see Figure 3) holding the volute case to the motor housing/seal plate assembly. Lift the motor housing/seal plate assembly off the volute case and lay it on its side. ME3H: Lay the pump on its side. Remove nine screws holding the suction plate to the bottom of the volute case. Carefully remove the suction plate and gasket. 3. Hold the shaft with a screwdriver in the slot on the end of the shaft. Carefully tap the impeller counterclockwise with a rubber mallet to loosen it. Unscrew and remove the impeller. 4. Pull the rotating half of the seal off of the shaft with your fingers, then use two straight-bladed screwdrivers to pry the stationary half of the seal out of the seal cavity in the seal plate. NOTE: Discard all the old seal parts. Do not try to reuse the old seal. 5. Clean the shaft and volute casing with a clean cloth. If there were any signs of water in the oil, air-dry the motor for several days to be sure that there is no moisture in the motor at reassembly. 6. Wipe an oil film onto the outside of the rubber ring on the stationary (carbon faced) half of the new seal. Don t get any oil on the carbon face of the seal. 7. Slide the stationary seal-half down the shaft and into the seal cavity in the seal plate, rubber ring first, carbon face out. Put a cardboard washer over the carbon face to protect it and press the seal half into the seal cavity, using a small piece of tubing or pipe as the press. Be sure that you don t chip, scratch, or crack the carbon seal face. 8. Once the stationary seal half is in place, check it to be sure that there are no chips, cracks, scratches, debris, dust, etc., on the carbon face of the seal. 9. Wipe a film of oil onto the impeller shaft, then slide the rotating (ceramic faced) half of the seal onto the shaft, ceramic face first, rubber surface out. When correctly installed, the carbon and ceramic faces will face each other. 10. Thread the impeller onto the shaft (turn clockwise) while holding the shaft with a straight-bladed screwdriver in the slot in the end of the shaft. Tighten the impeller on the shaft. Once the impeller is tight, spin the impeller/shaft assembly to be sure that there is no binding. 11. ME3F ONLY (ME3H go on to Step 12): Check the HUVA cup seal in the volute case inlet. If it shows signs of wear, replace it. 12. ME3F (See Below for ME3H): Turn the motor housing/seal plate assembly upright and set it in place in the volute case. Insert and tighten three cap screws to secure the volute case to the seal plate. ME3H: Replace the suction plate and gasket on the bottom of the volute casing. Replace and tighten the nine screws holding the plate to the casing. Stand the pump upright. 13. Refill the motor housing with fresh oil, using only Myers submersible transformer oil. After filling, use a dipstick to make sure that the oil is 3/4" below the top of the motor housing. 14. Replace the pump in the basin, reconnect the plumbing, plug it in, and fill the basin sufficiently to start the pump and check operation. The pump should run quietly, be vibration free, and pump down the basin normally. 14B 14A 14B 14A; Do not remove Figure 3: For Model ME3F, be sure to remove the three screws (Ref. No. 14B) holding the motor housing/seal plate assembly to the volute case, not the screws (Ref. No. 14A) holding the motor housing to the seal plate. 5

Grounded 115 or 230 Volt Outlet Minimum sump Diameter 12 Power Cord is 20 long, 3-conductor grounded cable 4 Ft. Min. Not To Scale 1-1/2 Shut-Off Valve 1-1/2 Check Valve with Rubber Sleeve Connectors 10-1/2 Min. Sump Basin 12-18 Dia.; Plastic, Fiberglass, or Concrete Bottom of Inlet Pipe 1-1/2 Discharge Pipe ABS or PVC (with adapters) or Galvanized Steel. If using Copper Pipe, thread a plastic fitting into pump discharge opening. Thread Copper Pipe adapter into fitting. 14 Min. Lifting Ring Float Switch Start Level 7 to 8 12 to 13 Stop Level Figure 4: Typical Sump Installation 6

Rail Support Not To Scale 45 Junction Box Structural Plastic Control Mounting Bracket (SST) 30 Dia. Basin Cover Valve Extension Handle 18 6 3/4 Galvanized Guide Rails Lift-Out Rope 1-1/2 Discharge, Effluent 1-1/2 Gate or Ball Valve, Effluent 1-1/2 PVC Discharge Pipe, Effluent High Water Alarm Level Inlet Hub (As Req d) 30 Dia. Concrete Well Brass Pitless Disconnect 1-1/2 Swing Check Valve, PVC, Effluent ME3H/ME3F Automatic Effluent Pump Figure 5: 30" Diameter Simplex Installation with Guide Rail Liftout System 7

Not To Scale 45 Junction Box Structural Plastic Control Mounting Bracket (SST) 30 Dia. Basin Cover 1-1/2 Union, PVC, Effluent 18 6 1-1/2 Gate or Ball Valve, Effluent 1-1/2 Conduit Req d. Lift-Out Rope 1-1/2 PVC Discharge Pipe, Effluent 1-1/2 Discharge, Effluent High Water Alarm Level Inlet Hub (As Req d) 30 Dia. Concrete Well 1-1/2 Swing Check Valve, PVC, Effluent ME3H/ME3F Automatic Effluent Pump Figure 6: 30" Diameter Simplex System with Union 8

REPAIR PARTS LIST Model ME3F Model ME3H 1 1 3 3 14B 11 5 13 7 8 9 10 12 14A 22 14A 15 16 17 11 5 7 8 9 10 12 13 16 23 15 19 18 Ref. Part No. Description Qty. Numbers 1 20' Power Cord (115V) 1 2168B048 1 20' Power Cord (230V) 1 2168B049 3 1/4" NPT Plug 1 * 5 Self-Tapping Screw (Manual) 1 * #10x3/8" 5 Self-Tapping Screw (Auto) 1 * #6x5/16" 8 Rotor with Shaft 1 22821A000 9 SST Thrust Washer 1 05030A243 10 Graphite Thrust Washer 1 05030A244 11 Motor Housing w/stator (115V) 1 23770D060K 11 Motor Housing w/stator (230V) 1 23770D061K Not Illustrated * Standard hardware item purchase locally. Ref. Part No. Description Qty. Numbers 12 1/2" Shaft Seal 1 21607A001 13 Rubber Gasket 1 05014A172 14A 1/4-20x7/8" Cap Screw 3 * 14B 1/4-20x7/8" Cap Screw (ME3F) 3 * 15 Volute Case (ME3H) 1 26221D000 15 Volute Case (ME3F) 1 26226D000 16 Impeller (ME3H) 1 26223C000 16 Impeller (ME3F) 1 25301B000 17 Gasket 1 26222C000 18 Suction Plate 1 26225C000 19 Self-Tapping Screw 9 * #10x1/2" 115V 20' Piggy-Back Switch 1 21813B131 230V 20' Piggy-Back Switch 1 21813B133 22 Seal Plate 1 26227D000 23 HUVA Cup Seal 1 22835A007 9

TROUBLES-REMEDIES Sudden Starts. If the power is on to the pump when thermal overload resets, the pump may start without warning. If you are working on the pump, you may get an electrical shock or the impeller may catch fingers or tools. Disconnect the power before servicing the pump. A. Pump fails to operate: 1. Check to be sure that power cord is securely plugged into outlet or securely wired into controller or switch box. 2. Check to be sure you have electrical power. Be sure that the piggyback plugs are tight. 3. Check that liquid fluid level is high enough to activate switch or controller. 4. Check to be sure that 1/8" (3 mm) vent hole in discharge pipe is not plugged. 5. Check for blockage in pump inlet, impeller, check valve or discharge pipe. 6. Disconnect the pump from the power source for a minimum of 30 minutes to allow the motor to cool and to protect yourself from sudden starts. See Warning above. Check for the cause of overheating. Pump is running dry because the float switch is caught up on something. Inlet pipe is plugged. Outlet pipe is plugged. 7. Motor windings may be open. Take unit to authorized service center. B. Pump fails to empty sump: 1. Be sure all valves in discharge pipe are fully open. 2. Clean out discharge pipe and check valve. 3. Check for blockage in pump inlet or impeller. 4. Pump not sized properly. A higher capacity pump may be required. C. Pump will not shut off: 1. Check switch or controller automatic floats for proper operation and location. See installation instructions for switch/controller. 2. If pump is completely inoperative or continues to malfunction, consult your local serviceman. LIMITED WARRANTY F.E. MYERS warrants to the original consumer purchaser ( Purchaser or You ) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Warranty Period Jet pumps, small centrifugal pumps, submersible pumps and related accessories Fibrewound Tanks Steel Pressure Tanks Sump/Sewage/Effluent Products whichever occurs first: 12 months from date of original installation, or 18 months from date of manufacture 5 years from date of original installation 5 years from date of original installation 12 months from date of original installation, or 18 months from date of manufacture Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extraquick trip overload relays of the recommended size or the warranty is void. Your only remedy, and F.E. MYERS s only duty, is that F.E. MYERS repair or replace defective products (at F.E. MYERS s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable. F.E. MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state. This warranty supersedes and replaces all previous warranty publications. F.E. MYERS 1101 Myers Parkway, Ashland, OH 44805-1989 Phone: 419-289-6898 Fax: 419-289-6658 www.femyers.com 10