The RTR Gen 3 troffer kit is designed by our expert in house lighting engineers and fabricated with custom made multi-stage roll forming machinery. This retrofit kit is an excellent alternative to tube kits and is ideally suited for prismatic lensed and recessed grid, suspended or surface mount troffers. Project Name: Catalog Number: Type: Date: SPECIFICATIONS Features Available in 2' and 4' lengths 3,500K and 4,000K color temperature Modular design with plug and play style connectors Connectors reduce chance of miswiring Familiar design and installation Construction White gloss painted aluminum enclosure Rust free Light weight Installer friendly Electrical 120-277 VAC universal voltage standard Power Factor >.9 & THD < 20% @277 &120 VAC on DLC listed models 0-10V dimming standard Name brand drivers Ambient Operating Range: -20 C to 44 C (-4 F to 111 F) TM-21 Reported Lumen Maintenance (L70) of >60k hrs, and Projected Lumen Maintenance of 157k hrs for 2x2 TM-21 Reported Lumen Maintenance (L70) of >60k hrs, and Projected Lumen Maintenance of 400k hrs for 2x4 ORDERING INFORMATION Optics Name brand LED arrays High efficiency LEDs White LED panel has 91% reflectance CRI > 84 on DLC listed models; high color rendering Frosted lens option available to reduce LED glare Warranty 7-year limited warranty Project specific warranty terms available Options Consult with your sales representative for additional options CERTIFICATIONS ADDITIONAL OPTIONS: TYPE DIMENSION LUMEN PACKAGE CCT* VOLTAGE LENS BACKUP CONTROL PACKAGING GEN RTR 2 2 x 2 40 4,000L 35 3,500K Blank 120/277v L E Emergency Backup X DP Distributor Pack 03 4 2 x 4 45 4,500L 40 4,000K CP Contractor Pack RTR -03 Example Ordering Number: RTR24040-L-CP-03 2x2 only available in 4,000lm 2x4 only available in 4,500lm 148 Maritime Drive / Sanford, Florida 32771 / Toll Free 1.888.302.8920 / www.envirobrite.net / PG 1 rev 05.25.2018
PHOTOMETRIC DATA Below is the photometric data information for a 2 x 2 fixture. Zonal lumen summary Polar plot ZONE LUMENS % OF FIXTURE 0-30 1204 27.4 0-40 1988 45.3 0-60 3552 80.9 0-90 4391 100.0 90-120 0 0.0 90-150 0 0.0 90.0 88.0 86.0 84.0 82.0 80.0 78.0 76.0 74.0 72.0 70.0 66.0 0.0-180.0 22.5-202.5 45.0-225.0 67.5-247.5 90.0-270.0 90-180 0 0.0 0-180 4391 100.0 64.0 62.0 60.0 58.0 56.0 54.0 52.0 50.0 48.0 Light Output (Lumens) 4391 46.0 Watts 32 Lumens per Watt (Efficacy) 136 Color Accuracy Color Rendering Index (CRI) 85 44.0 42.0 40.0 38.0 36.0 2700K 3000K 4500K 6500K 34.0 All results are according to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. The U.S. Department of Energy (DOE) verifies product test data and results. 32.0 Visit www.lightingfacts.com for the Label Reference Guide. Registration Number: 61VT-SNW4AT (2/27/2018) Model Number: RTR-24040-[blank,E,X,DP,CP]-03 Type: Retrofit Kit - Troffer/Grid Ceiling 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 148 Maritime Drive / Sanford, Florida 32771 / Toll Free 1.888.302.8920 / www.envirobrite.net / PG 2 rev 05.25.2018
PHOTOMETRIC DATA Below is the photometric data information for a 2 x 4 fixture. Zonal lumen summary Polar plot ZONE LUMENS % OF FIXTURE 0-30 1298 26.8 0-40 2148 44.3 0-60 3880 80.1 0-90 4844 100.0 90-120 0 0.0 90-150 0 0.0 90.0 88.0 86.0 84.0 82.0 80.0 78.0 76.0 74.0 72.0 70.0 66.0 0.0-180.0 22.5-202.5 45.0-225.0 67.5-247.5 90.0-270.0 90-180 0 0.0 0-180 4844 100.0 64.0 62.0 60.0 58.0 56.0 54.0 52.0 50.0 48.0 Light Output (Lumens) 4844 46.0 Watts 32 Lumens per Watt (Efficacy) 150.95 Color Accuracy Color Rendering Index (CRI) 86 44.0 42.0 40.0 38.0 36.0 2700K 3000K 4500K 6500K 34.0 All results are according to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. The U.S. Department of Energy (DOE) verifies product test data and results. 32.0 Visit www.lightingfacts.com for the Label Reference Guide. Registration Number: 61VT-AE1LAH (2/27/2018) Model Number: RTR44040-[blank,E,X,DP,CP]-03 Type: Retrofit Kit - Troffer/Grid Ceiling 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 148 Maritime Drive / Sanford, Florida 32771 / Toll Free 1.888.302.8920 / www.envirobrite.net / PG 3 rev 05.25.2018
SCALED PERFORMANCE TABLE Part # Dimensions Initial Light Output (lumens) Input Power (W) Luminaire Efficacy (lm/w) CCT DLCv4.1 Tier RTR24035-L[blank,E,X,DP,CP]-03 2x2 3,545 31 115 3,500 Standard RTR24040-L[blank,E,X,DP,CP]-03 2x2 3,761 32 116 4,000 Standard RTR24035-[blank,E,X,DP,CP]-03 2x2 4,139 31 134 3,500 Premium RTR24040-[blank,E,X,DP,CP]-03 2x2 4,391 32 136 4,000 Premium RTR44535-L[blank,E,X,DP,CP]-03 2x4 3,965 31 129 3,500 Premium RTR44540-L[blank,E,X,DP,CP]-03 2x4 4,207 32 131 4,000 Premium RTR44535-[blank,E,X,DP,CP]-03 2x4 4,566 31 149 3,500 Premium RTR44540-[blank,E,X,DP,CP]-03 2x4 4,844 32 151 4,000 Premium 148 Maritime Drive / Sanford, Florida 32771 / Toll Free 1.888.302.8920 / www.envirobrite.net / PG 4 rev 05.25.2018
FIXTURE DIMENSIONS Dimensions for 2x2 fixture 11.9 2.0 1.5 20.5 Dimensions for 2x4 fixture 11.9 1.5 44.5 148 Maritime Drive / Sanford, Florida 32771 / Toll Free 1.888.302.8920 / www.envirobrite.net / PG 5 rev 05.25.2018
ADDITIONAL PRODUCT IMAGES 2x2 fixture Lens 2x4 fixture Lens 148 Maritime Drive / Sanford, Florida 32771 / Toll Free 1.888.302.8920 / www.envirobrite.net / PG 6 rev 05.25.2018